SECTION 3 Exterior Sign Drawings Orientation / Information Identification Regulatory Speciality / LEED® SECTION 3 Exterior Sign Drawings Orientation / Information 31 Cleveland State University Sign Standards Manual SECTION 3 A1 Information/Map Kiosk Freestanding L C A A EQ L 10" 3" L CLEVELAND STATE UNIVERSITY EQ 2 CLEVELAND STATE UNIVERSITY AC CAMPUS MAP Back-lit map (map artwork to be provided by CSU) L FRONT ELEVATION SCALE: 3/8” = 1’-0” SIDE ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION LAYOUT SCALE: 3/4" = 1'-0" A1 32 Cleveland State University Sign Standards Manual SECTION 3 A1 Information/Map Kiosk Freestanding 1'-2" diameter concrete footing (shown dashed) 6 1/2" 4 1/2" TOP SCALE: 3/8” = 1'-0" 5'-3" 1" 1" 3 1/2" 4'-6" CLEVELAND STATE UNIVERSITY 6 1/2" 3 1/2" White LED internally illuminated acrylic push through letters to be flush with sign face Bleed face aluminum cabinet (retainerless look) to contain back-lit updateable map 4'-0" 3'-8" Reveal painted to match post 6'-10" 3 1/2" x 6 1/2" aluminum post directly buried in footer Top of footings to be 1" above grade, typical, tapered for water drainage 2'-10" 1'-2" diameter concrete footing (shown dashed) FRONT ELEVATION SCALE: 3/8" = 1'-0" SECTION A-A SCALE: 3/8" = 1'-0" A1 33 Cleveland State University Sign Standards Manual SECTION 3 Exterior Sign Drawings Identification 34 Cleveland State University Sign Standards Manual SECTION 3 B1 Primary Building ID Monument I C A I TOP SCALE: 3/8” = 1’-0” A I 2 I 2 C 2 AC MUSIC & COMMUNICATION I I C SIDE ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION SCALE: 3/8” = 1’-0” SIDE ELEVATION SCALE: 3/8" = 1'-0" B1 35 Cleveland State University Sign Standards Manual SECTION 3 B1 Primary Building ID Monument White LED illuminated top edge Concrete footing (shown dashed) TOP SCALE: 3/4" = 1'-0" White LED internally illuminated acrylic push through letters to be flush with sign face 8'-9" 9" 9'-0" 3/8" 6" EQ 1 1/2" EQ 6" Aluminum sign panel 4" 7" 4 1/4" cap ht. MUSIC & COMMUNICATION 1 1/2" White LED illuminated side edge 6" cap ht. 3'-0" Tracking +25% 3/8" thick dimensional numbers 4" 1" Concrete footing (shown dashed) SIDE ELEVATION SCALE: 3/4" = 1'-0" Top of footings to be 1" above grade, typical. Tapered for water drainage Aluminum sign panel FRONT ELEVATION LAYOUT SCALE: 3/4" = 1'-0" B1 36 Cleveland State University Sign Standards Manual 3'-2" SECTION 3 B1 Primary Building ID Monument Alternate Sign height can be increased to accomodate longer messages. Use the below example as a base for non-typical messages. Note: All dimensions the same unless otherwise noted. C 2 AC C 1 AC C 1 UL JOSEPH E. SMITH CENTER FOR INNOVATION IN MEDICAL PROFESSIONS White, LED internally illuminated acrylic push through letters to be flush with sign face, tracking +25% NEOMED-CSU Partnership for Urban Health 4 1/2" 6" cap ht. 2" 6" cap ht. 2" 6" cap ht. 3'-9" 3'-11" 4 7/8" 4 1/8" ALT FRONT ELEVATION SCALE: 3/4" = 1'-0" B1 37 Cleveland State University Sign Standards Manual SECTION 3 B2 Secondary Building ID Freestanding Content horizontally centered on panel 3'-0" 3" 7" 1'-3" A 5" 3'-0" L MUSIC & COMMUNICATION C 2 2001 C 1 Active text area C MUSIC & COMMUNICATION 8 5/8" AC 3 1/2" cap ht. 1 5/8" 3 1/2" cap ht. 6 1/8" UL 2001 2 3/4" cap ht. 3 1/2" 3" J 2'-6" 3" Active text area FRONT ELEVATION SCALE: 3/8” = 1’ SIDE ELEVATION SCALE: 3/8" = 1' FRONT ELEVATION LAYOUT SCALE: 1" = 1' B2 38 Cleveland State University Sign Standards Manual Sign height can be increased to accomodate longer messages. Use the below example as a base for non-typical messages. Note: All dimensions the same unless otherwise noted. SECTION 3 B2 Secondary Building ID Freestanding 10" diameter concrete footing (shown dashed) 1'-1 3/4" 5" 3" Extended active text area MONTE AHUJA COLLEGE OF BUSINESS 3'-4 1/2" 2121 TOP SCALE: 3/8” = 1’-0” First surface painted white seal A 1" 2" 3'-0" 2'-8" 1" 3'-0" MUSIC & COMMUNICATION 2" Single- or double-sided bleed face, white LED internally illuminated aluminum cabinet (retainerless look), secured with countersunk fastners on top and bottom for access 5" Extended active text area Reveal painted to match post Acrylic push through letters to be flush with sign face 1'-6 7/8" 2001 5'-9" max ht. 6 1/8" 2 1/2" cap ht. 2" x 5" aluminum post A FRONT ELEVATION SCALE: 3/8" = 1' Speech & Hearing Clinic 3'-10" EQ EQ 2 1/2" Top of footings to be min. 1" above grade, typical. Tapered for water drainage 2'-9" CENTER FOR INNOVATION IN MEDICAL PROFESSIONS 2'-6" 1/4" thick rule 10" diameter concrete footing (shown dashed) SECTION A-A SCALE: 3/8" = 1' ALT FRONT ELEVATION SCALE: 3/8" = 1' B2 39 Cleveland State University Sign Standards Manual SECTION 3 B2.1 Secondary Building ID Wall-Mounted 4" TOP SCALE: 3/8” = 1’-0” Mount flush to wall with conceled fastners 3'-0" MUSIC & COMMUNICATION 2001 3'-0" MUSIC & COMMUNICATION 2001 5'-9" preferred Bleed face, white LED internally illuminated aluminum cabinet (retainerless look), secured with countersunk fastners on top and bottom for access 4" Acrylic push through letters to be flush with sign face Exterior surface of building (material will vary per location) 2'-9" FRONT ELEVATION SCALE: 3/8” = 1’ TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' SIDE ELEVATION SCALE: 3/8" = 1' B2.1 40 Cleveland State University Sign Standards Manual SECTION 3 B3 Building ID Dimensional Letters L L F L 2 White LED back-lit pin-mounted letters, returns same color as letter face Note: Letter depth proportional to letter height, approx 10:1, consult with fabricator to determine best depth for size and application. Donor name AC PREFERRED SEAL SCALE: 1/8" = 1' 1'-10" (ht. will vary) L 1 AC Flush mounted for non-illuminated, letter, returns same as letter face Building name PREFERRED DIMENSIONAL LETTERS SCALE: 1/8” = 1’ TYP. SECTION SCALE: 1/8" = 1' F Alternate Color Dark Gray letters may be used only if the silver does not provide enough contrast with the background. ALT. SECTION SCALE: 1/8" = 1' ALT. OPTION SCALE: 1/8" = 1' Individual letters and graphics is the preferred design. If size becomes too small to allow for individual elements, use the alternate option. Fabrication capabilities vary per contractor–consult sign contractor. Notes: The seal with a back-lit is acceptable but not recommended (varies per project). For alternate option, use the reversed seal (page 3) when mounting to buildings). Note: All dimensional letters and optional elements are considered custom and are to be approved by OUA prior to fabrication. Signs shown here are examples of typical design and material options for custom Identification. B3 41 Cleveland State University Sign Standards Manual SECTION 3 B4 Building ID Vinyl Music & Communication Music & Communication When there are more than 2 doors, mirror the arrangement, see drawing to the left. H HC 2 UL Align to center of glass on exterior of door ALT ELEVATION SCALE: 1/8" = 1' Note: Coordinate with door hardware Seal artwork to be provided by CSU 1'-0" max size 5 1/2" Music & Communication Music & Communication 4" 7/8" 2 1/2" cap ht. max size 4" 6'-5" Active text area 4" min. to glass edge on each side, can accomodate up to 4 lines of text Sign type D1, see page 48 for placement FRONT ELEVATION SCALE: 3/8” = 1’ 42 Cleveland State University Sign Standards Manual both seal and text to be frosted film Text area can vary based on glass size, seal and text should be scaled proportionally TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' Top of seal at 6'-0" at interior applications DETAIL SCALE: 1" = 1' B4 3'-3" 1'-8" SECTION 3 B5 Content horizontally centered on panel Parking Structure / Lot ID Freestanding 5" 1'-8" A 5" CSU LOT C 1 AC Content vertically centered on panel, can accomodate 2 lines of text C 2 UL C L 6" cap ht. RG C 4'-6" 3" 11" cap ht. 4" 3 1/2" min. Visitor Parking 4 1/2" cap ht. 2 1/2" 1'-10" 8" 3 1/2" min. K EQ 2'-8" EQ Active text area FRONT ELEVATION SCALE: 3/8” = 1’ SIDE ELEVATION SCALE: 3/8" = 1' DETAIL LAYOUT SCALE: 3/4" = 1' B5 43 Cleveland State University Sign Standards Manual SECTION 3 B5 Parking Structure / Lot ID Freestanding 3'-3" 8" Concrete base (shown dashed) 6" 8" TOP SCALE: 3/8” = 1’-0” Note: All dimensions the same unless otherwise noted. 6" 4'-6" White LED internally illuminated aluminum cabinet with acrylic push through letters and symbols to be flush with sign face 8'-6" PG Green Permit 103 White Permit 6" icon L C Changable aluminum panels 1'-10" PG Alt. message (centered vert.) Visitor 1'-10" Concrete base 4" Optional amber LED display showing available parking spaces Concrete footing (shown dashed) FRONT ELEVATION SCALE: 3/8" = 1'-0" SIDE ELEVATION SCALE: 3/8" = 1'-0" ALT FRONT ELEVATIONS SCALE: 3/8" = 1'-0" B5 44 Cleveland State University Sign Standards Manual SECTION 3 B5.1 Parking Structure / Lot ID Flag-Mounted 8" 1 1/2" 6" A 4'-6" 6'-4" 6'-0" clearance to vary per location, verify per local codes and ordances and OUA 1'-10" Aluminum reveal (shown dashed) 3'-3" A FRONT ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION SCALE: 3/8" = 1'-0" Changable aluminum panels SECTION A–A SCALE: 3/8" = 1'-0" B5.1 45 Cleveland State University Sign Standards Manual SECTION 3 Exterior Sign Drawings Regulatory 46 Cleveland State University Sign Standards Manual SECTION 3 C1 Regulatory Signs Post Panels vary Cap to be affixed to top of post 2" Aluminum square post 2" 8'-0" I ELEVATION SCALE: 3/8" = 1' BACK ELEVATION SCALE: 3/8" = 1' 3D DETAIL SCALE: 3/8" = 1' C1 47 Cleveland State University Sign Standards Manual SECTION 3 Exterior Sign Drawings Speciality / LEED® 48 Cleveland State University Sign Standards Manual SECTION 3 D1 No Trespassing, Smoking, Firearms Music & Communication Music & Communication When there are more than 2 doors, mirror the arrangement, see drawing to the left. ALT ELEVATION SCALE: 1/8" = 1' Align to center of glass Standard vinyl CSU No trespassing, firearms and smoking sign, centered vertically on exterior of glass. 10" 8" Music & Communication Note: Coordinate with door hardware Music & Communication Artwork to be provided by CSU 4'-9" Sign type B4, see page 41 for placement FRONT ELEVATION SCALE: 3/8” = 1’ TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 1 1/2" = 1' D1 49 Cleveland State University Sign Standards Manual SECTION 3 D2 Welcome Artwork to be provided by CSU DETAIL SCALE: 1" = 1' Align to center of glass Standard vinyl Welcome sign, centered vertically on exterior of glass. 10" Note: Coordinate with door hardware 8 1/2" Placed above the standard CSU No trespassing, firearms and smoking sign, vertically centered. 4'-9" 4'-9" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' ALT ELEVATION SCALE: 3/8" = 1' D2 50 Cleveland State University Sign Standards Manual SECTION 3 D3 No Smoking Pole-Mounted Stainless steel strap to match color of pole if possible Mounting channel or bracket Existing pole 1/8" thick aluminum plate TOP SCALE: 1 1/2" = 1' Existing pole 1'-0" B A Printed graphic on vinyl or applied vinyl on white sign face, mounted to 1/8" thick aluminum plate (artwork supplied by CSU) B 1'-10" A 6'-8" NO SMOKING ON PUBLIC SIDEWALKS WITHIN 25 FEET OF BUILDING B A C ELEVATION SCALE: 3/8" = 1' DETAIL SCALE: 1 1/2" = 1' D3 51 Cleveland State University Sign Standards Manual SECTION 3 D3.1 No Smoking Post-Mounted 1'-0" I 2" thick square aluminum post B A Printed graphic on vinyl or applied vinyl on white sign face, mounted to 1/8" thick aluminum plate (artwork supplied by CSU) B 1'-10" A 6'-8" NO SMOKING ON PUBLIC SIDEWALKS WITHIN 25 FEET OF BUILDING B A C ELEVATION SCALE: 3/8" = 1' DETAIL SCALE: 1 1/2" = 1' D3.1 52 Cleveland State University Sign Standards Manual SECTION 4 Interior Sign Drawings Orientation / Information Directional Identification Regulatory SECTION 4 Interior Sign Drawings Orientation / Information 54 Cleveland State University Sign Standards Manual SECTION 4 E1 Electronic Information Kiosk Freestanding A A C E C LEVEL 3 Innovation Center CIHP Administration NEOMED Offices LEVEL 2 C Health Services Speech & Hearing Clinic Classrooms LEVEL 1 40" touchscreen Innovation Center Café Labs F I I I E F SIDE ELEVATION SCALE: 3/8" = 1'-0" F FRONT ELEVATION SCALE: 3/8” = 1’-0” SIDE ELEVATION SCALE: 3/8" = 1'-0" BACK ELEVATION SCALE: 3/8” = 1’-0” E1 55 Cleveland State University Sign Standards Manual SECTION 4 E1 Acrylic dimensional symbol, to overlap symbol on front Electronic Information Kiosk Freestanding 2'-10 1/2" 6" EQ +/- 1'-7 1/2" 1 1/4" 1/4" 2'-4 1/2" 1/4" thick white acrylic dimensional symbol 2 1/2" 2 1/2" EQ 1" 1" 1 1/4" 3" 4 1/4" LEVEL 3 Innovation Center CIHP Administration NEOMED Offices LEVEL 2 Health Services Speech & Hearing Clinic Classrooms LEVEL 1 40" touchscreen Painted seal at 15˚ angle, bleeds off right side, same as front 1" Innovation Center Surface applied vinyl text and rule lines, Level Directory listing can show a max. of 5 levels with the first floor listed on bottom Café Labs 6'-0" Aluminum fabricated cabinet with hidden fastners, mounted to floor 5'-7" 4 1/4" Painted seal at 15˚ angle, bleeds off right side 1'-8 1/2" 3" 2 1/2" 1'-10" 5" 2'-0" 7" FRONT ELEVATION SCALE: 3/4" = 1'-0" SIDE ELEVATION SCALE: 3/4" = 1'-0" BACK ELEVATION SCALE: 3/4" = 1'-0" E1 56 Cleveland State University Sign Standards Manual SECTION 4 E1 4" Electronic Information Kiosk Freestanding 4" 1 1/4" 1 1/4" 8" 1 1/4" 2 1/2" 1 7/8" LEVEL 3 Innovation Center LEVEL 3 Innovation Center CIHP Administration CIHP Administration NEOMED Offices 3/16" 5/8" cap ht. 3/4" NEOMED Offices LEVEL 2 1 3/16" Health Services Speech & Hearing Clinic LEVEL 2 Classrooms Health Services LEVEL 1 40" touchscreen 3/8" 3/4" 1/16" thick rule Speech & Hearing Clinic Innovation Center Café Classrooms Labs LEVEL 1 L C Innovation Center 5/8" Café 3/4" Labs FRONT ELEVATION LAYOUT SCALE: 1 1/2" = 1'-0" APPLIED TEXT DETAIL SCALE: 3" = 1'-0" E1 57 Cleveland State University Sign Standards Manual SECTION 4 E1.1 Electronic Information Kiosk Wall-Mounted Note: All dimensions the same as freestanding unless otherwise noted. See sign type E1. 1" 2 1/2" A LEVEL 3 Innovation Center IM303 C CIHP Administration NEOMED Offices LEVEL 2 LEVEL 3 Innovation Center Health Services C Speech & Hearing Clinic Classrooms CIHP Administration NEOMED Offices LEVEL 1 LEVEL 2 3'-6 1/2" Health Services Speech & Hearing Clinic Classrooms LEVEL 1 F 40" touchscreen Innovation Center Café Labs 3'-4" 40" touchscreen F Innovation Center IM105 Café Labs I I 2'-5" min. 3" 4" SIDE ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION SCALE: 3/8” = 1’-0” SIDE ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION SCALE: 3/4" = 1'-0" E1.1 58 Cleveland State University Sign Standards Manual SECTION 4 E2 Level Directory Wall-Mounted Note: If being used in Inner Link, see next page See page 82 for frame construction Mount flush to wall with VHB tape & silicone adhesive 11 1/4" 11" 3/4" 1" 2 1 AC UL F LEVEL 3 F Innovation Center CIMP Administration NEOMED Offices 7/16" cap ht. 7/16" 9/16" cap ht. 9/16" D Cover stock or similar insert with photo quality printed graphics, one-piece to fit frame, to be updated by CSU, JRS snap-in lens to fit frame 1/2" LEVEL 2 CL 1'-3 1/4" 5'-0" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' 1'-3" 3/16" Health Services Speech & Hearing Clinic Classrooms WALL E 1/16" thick x 9 1/2 " long rule LEVEL 1 Innovation Center 11/16" Café 1/2" Labs DETAIL SCALE: 3" = 1' SIDE SCALE: 3" = 1' E2 59 Cleveland State University Sign Standards Manual SECTION 4 E2 Level Directory Wall-Mounted – Alternate Note: Alternate to be used on the Inner Link to help orientation. All dimensions and specs are the same unless otherwise noted (see previous page). See page 82 for frame construction 11 1/4" 11" F 2 3/4" 1/2" AC BUILDING NAME LEVEL 3 1/2" EQ 5/32" cap ht. EQ LEVEL 2 1'-5 1/4" 1'-5" Health Services Speech & Hearing Clinic Destination LEVEL 1 5'-0" ALT TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' BN A 2 letter building designation 5/32" Innovation Center CIMP Administration NEOMED Offices CL E Seal printed at 15° angle A 1/8" thick rule D Cover stock or similar insert with photo quality printed graphics, one-piece to fit frame, to be updated by CSU, JRS snap-in lens to fit frame E 1/16" thick x 9 1/2 " long rule Innovation Center Café Destination DETAIL (ALT BUILDING NAME) SCALE: 3" = 1' E2 60 Cleveland State University Sign Standards Manual SECTION 4 Interior Sign Drawings Directional 61 Cleveland State University Sign Standards Manual 1'-3 1/4" 15" W SECTION 4 Student Lounge F1 Wall Directional Restrooms 2 1/4" min. 8" H Sign width is the same as larger sign type. Rooms IM310–IM347 2 7/8" ALT DETAIL – SMALL SCALE: 1 1/2" = 1' L C 2 3/8" EQ EQ 3/4" cap ht. 3/8" 3/4" cap ht. L C 1" Note: See page 82 for frame construction = (4) lines of text All type F 1 A 1" high arrow, subsurface applied UL 1/8" printed border, color (E) Rooms IM115–IM125 & IM152–IM162 D 1" A 1/8" thick rule 1/8" CL 3/4" cap ht. 11"1'-0H 3/4" 1" 1'-0 1/2" L C L C L C 1" 1" Rooms IM140–IM157 Elevator to Speech & Hearing Clinic 1" E 1/16" thick x 11 5/8" long rule 1" F 3" min. 5'-0" 3 7/8" 1'-3" Frameless sign,insert with Cover stock or similar photo quality printed graphics, printed on backside of one-piece to fit frame, JRS 1/8" thick matte acrylic. snap-in lens to fit frame Similar to "Operational" Sign Type G5 1'-3 1/4" 15" W TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 3" = 1' LARGE = (6) lines of text 62 Cleveland State University Sign Standards Manual F1 SECTION 4 Office of Disability Services F2 Overhead Directional Hanging 1/4" 2 1/2" 2 1/2" 12"H if 2 lines of text E L C ing DETAIL (ALT : LONG MESSAGE) SCALE: 3/8" = 1' Rec 5" Science Building Recreation Center 2 message will require (3) cables/attachment points L C ELEVATION (ALT : (2) MESSAGES) SCALE: 3/8" = 1' DETAIL (BETWEEN (2) MESSAGES) SCALE: 3" = 1' 8" Width will vary based on message (min. 36" – max. 48") White ceiling grid J-hook provided byattachment FM Cable to attach to existing ceiling or grid (length and to be verified and determined by fabricator per ceiling conditions; Loop aircraft cable around hook and crimp ceiling attachments available at www.griplocksystems.com) in place by FM *If name exceeds 48" length, change cap height to 3.5” Aircraft cable or similar min. 8'-0" clearance A 4 1/2" F 1 1/8" thk. Polymetal panel, printed on both sides PVC background D UL panel Recreation Center L C 3" cap ht. 2 1/2" 2" ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' 3 3/4" DETAIL SCALE: 3" = 1' 2" A All edges of background panel MBS Standoffs 2 1/2" Ceiling mount stainless steel 3/4" for cable system up to 3/8" panels SIDE SCALE: 3" = 1' F2 63 Cleveland State University Sign Standards Manual SECTION 4 F2.1 Overhead Directional Ceiling-Mounted Note: To be used as alternate to hanging overhead directional (see previous page) if not enough clearance between floor and ceiling. All dimensions and specs are the same unless otherwise noted (see previous page). Science Building Recreation Center L C 2 message panel 8" Width will vary based on message (min. 36" – max. 48"*) Ceiling mount system TBD. Finish to match JRS frame, p. 83 ELEVATION (ALT : (2) MESSAGES) SCALE: 3/8" = 1' *If name exceeds 48" length, change cap height to 3.5” min. 8'-0" clearance 3/4" Typical ceiling-mount, finish to match frame system (see page 82) L C Recreation Center 3/4" ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 3" = 1' SIDE SCALE: 3" = 1' F2.1 64 Cleveland State University Sign Standards Manual 1'-11" SECTION 4 F3 1'-6 1/2" Free-Standing Directional See page 7 for university colors, use different colors to denote departments or rooms 2 AC R 1/2" 1" 1'-6" LEVEL 1 1/2" AC Map artwork to be provided by CSU F A LEVEL 1 A 1 3/4" LEVEL 1 E 2 2" 1'-4 1/4" A A TOP SCALE: 3/4” = 1’-0” LEVEL 2 LEVEL 3 2 2'-6" AC LEVEL 1 LEVEL 2 LEVEL 3 Innovation Center Health Services Innovation Center Innovation Center Health Services Innovation Center Café Speech & Hearing Clinic Faculty Offices Café Speech & Hearing Clinic Faculty Offices Labs Classrooms NEOMED Administration Labs Classrooms NEOMED Administration UL F 1 Green denotes current level UL 5'-1" I Aluminum fabricated self-standing sign with direct print changeable panels 5'-0" 2" 2'-6" E I 1'-5 1/8" 5" 1'-6 1/2" FRONT ELEVATION SCALE: 3/8” = 1’-0” SIDE ELEVATION SCALE: 3/8" = 1'-0" FRONT ELEVATION SCALE: 3/4” = 1’-0” 1/4” thick aluminum plate with neoprene pad 1'-11" SIDE ELEVATION SCALE: 3/4” = 1’-0” F3 65 Cleveland State University Sign Standards Manual Active text/map area SECTION 4 F3 1" Free-Standing Directional Green panel 1 1/2" 3/4" cap ht. Active map area Current level, use level insted of floor 3/4" LEVEL 1 1" Optional custom map printed directly to aluminum face, if map is not used, this area can accomodate additional directory listings (map artwork to be provided by CSU) 1'-3" 1/16" thick x 1' 4" long rule 3/4" 1/4" 1/4" cap ht. 5/16" cap ht. LEVEL 2 LEVEL 3 Innovation Center Health Services Innovation Center Café Speech & Hearing Clinic Faculty Offices Classrooms NEOMED Administration L C 3/8" LEVEL 1 3/8" Labs 3/8" Level directory, can accomodate 4 columns up to 5 locations for each level, current level is highlighted in color A 1/4" FRONT LAYOUT SCALE: 3" = 1'-0" F3 66 Cleveland State University Sign Standards Manual SECTION 4 Interior Sign Drawings Identification 67 Cleveland State University Sign Standards Manual SECTION 4 G1 Flag-Mounted ID Note: See page 82 for frame construction 1'-0 1/4" Typical wall-mount, finish to match frame system (see page 82) 1'-0" 9" D EQ I 1 1/2" 1 1/2" F 1'-0" Active area 1'-0 1/4" 10" 6'-8" min. EQ Surface printed directly to panel, symbol to fit within 9" square, centered in panel, see the next page for specific measurements for stair symbol FRONT ELEVATION SCALE: 3/8” = 1’-0” FRONT DETAIL SCALE: 3” = 1’-0” 1/2" 1/2" 1/8" TOP DETAIL SCALE: 3” = 1’-0” G1 68 Cleveland State University Sign Standards Manual SECTION 4 G1 Flag-Mounted ID Active area 9" Active area 9" 8 1/2" 9" 8 1/2" Active area Active area ALT FRONT DETAIL SCALE: 1 1/2” = 1’-0” Active area Subsurface background printed directly to back of lens, symbol to fit within 9" square, centered on panel ALT FRONT DETAIL SCALE: 3” = 1’-0” G1 69 Cleveland State University Sign Standards Manual SECTION 4 G2 Public Convenience ID Note: See page 82 for frame construction 6 1/4" Active area 4 1/2" F 3/4" Active area 3/4" 3/4" D Subsurface background and symbol printed directly to back of JRS snap-in lens, symbol fits within 4 1/2" square, centered in panel 4 1/2" RESTROOM Rest room MU285 MU285 10 1/4" 3/4" A 1/8" 3/8" WOMEN 5/8" cap ht. 5'-0" 3/8" 1/4" 5/8" IM128 Subsurface rule printed directly to back of JRS snap-in lens F 1 AC 1/32" raised text 4 WOMEN IM128 N/A 1/2" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8” = 1’-0” DETAIL SCALE: 1” = 3” SELECTED ALT MESSAGES SCALE: 3” = 1’-0” G2 70 Cleveland State University Sign Standards Manual SECTION 4 G2 Public Convenience ID Active area Active area 4" 4" 1" 1" 1" 1" “Men”, “Women” and “Stair” symbols fit within 4" square, centered in panel 4" 1" 1" WOMEN IM128 4" Active area Active area 1" 1" CENTRAL STAIR 1/2" cap ht. 1/4" Authorized Personnel Only F 1 UL 1/32" raised text SELECTED ALT SYMBOL SIZES SCALE: 1” = 3” G2 71 Cleveland State University Sign Standards Manual SECTION 4 G3 Department ID Note: See page 82 for frame construction 8 1/4" 8" C 8 1/4" 8" Administration G 2 UL Firstname Lastname, Director Firstname Lastname, Admin. Assistant Firstname Lastname, Admission Firstname Lastname, Advisor Firstname Lastname, Campus Coord. G 1 UL White cover stock or similar insert with black printed text, to be updated by CSU A 1/8" thick subsurface rule printed directly to back of JRS snap-in lens E Subsurface seal printed directly to back of JRS snap-in lens at 15˚ angle 1/8" 5'-0" 3/8" 1/4" 5/8" 3/8" 3/8" IM307 2" IM30 7 1/2" 4 N/A F 1 D AC 2 1/8" Subsurface background printed directly to back of JRS snap-in lens 1/32" Rowmark raised text TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8” = 1’-0” DETAIL SCALE: 1” = 3” G3 72 Cleveland State University Sign Standards Manual SECTION 4 G4 Public Room / Office ID Note: See page 82 for frame construction All text/graphic dimensions and specifications same as sign type G3 (previous page) unless otherwise noted 6 1/4" 6" C Firstname Lastname G 2 UL Department G 1 UL A 1/8" thick subsurface rule printed directly to back of JRS snap-in lens 6 1/4" 6" 5'-0" 4 TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8” = 1’-0” 73 Cleveland State University Sign Standards Manual E Subsurface seal printed directly to back of JRS snap-in lens at 15˚ angle IM120 Notebar provided at all Offices, Conference, and Classrooms to post room schedules White cover stock or similar insert with black printed text, to be updated by CSU N/A D Subsurface background printed directly to back of JRS snap-in lens F 1 AC 1/32" Rowmark raised text DETAIL SCALE: 1” = 3” G4 SECTION 4 G5 Operational Room ID 1/2" Speech Acoustics & Perception Lab 1/2" cap ht. 1/4" F 2 UL Subsurface applied vinyl IM312 F 2 AC 1/32" Rowmark raised text IM312 4 4 1/2" 5/8" cap ht. 3/8" 1 1/8" D 1/8" Matte/non-glare acrylic panel subsurface background printed directly to panel 1/2" 1/2" 1/2" cap ht. N/A Electrical F 2 UL 1/8" Subsurface applied vinyl or direct print D WALL 4 1/2" 5'-0" 5/8" cap ht. 3/8" 1 1/8" IM108-C F 2 IM108-C 4 AC 1/32" Rowmark raised text N/A 6" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8” = 1’-0” DETAIL SCALE: 1” = 2” SECTION SCALE: 1” = 2” G5 74 Cleveland State University Sign Standards Manual SECTION 4 G6 Name Plate Mounting conditions vary upon location and fixtures Note: See page 82 for frame construction 3" 4" 6 1/4" 6" C 2 3/4" 2 1/2" Firstname Lastname G 2 UL Department G 1 UL White cover stock or similar insert with black printed text, to be updated by CSU JRS snap-in lens TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8” = 1’-0” DETAIL SCALE: 1” = 3” G6 75 Cleveland State University Sign Standards Manual SECTION 4 Interior Sign Drawings Regulatory 76 Cleveland State University Sign Standards Manual SECTION 4 H1 Evacuation Plan Note: See page 82 for frame construction Header and footer, including red rule lines, subsurface printed directly to lens 11 1/4" 11" Active map area 10" 1/2" 1/2" 3/4" cap ht. 1/2" 1/8" 1/2" F 1 AC D EMERGENCY PLAN M 1/8" thick subsurface rule line LEVEL 1 1'-1 1/4" 1'-1" 5'-0" Active map area 1/2" LEGEND D YOU ARE HERE 7 1/4" Primary Evacuation Route Secondary Evacuation Route Cover stock or similar insert with photo quality printed graphics, one-piece to fit frame, JRS snap-in lens to fit frame 1/2" EQ In Fire Emergency Do Not Use Elevators, Use Exit Stairs 2 13/16" EQ 1/2" 7/8" F 1 UL 1/2" 7/16" cap ht. M 1/8" thick subsurface rule line 3/16" 1/2" D F TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 3" = 1' H1 77 Cleveland State University Sign Standards Manual Content horizontally centered on panel SECTION 4 H2 Inside Stairwell Egress / Level ID F 1 1 1/2" 1 1/2" cap ht. 1" FLOORS 1–4 NO ROOF ACCESS 1/2" 1 1/8" cap ht. 1" 1" LEVEL 2" cap ht. 1'-9" 1/2" 5 1/4" cap ht. 1/4" AC CENTRAL STAIR 1 1/8" cap ht. 5'-0" Note: All type 1/32" raised text 1/2" 1/2" 1" 4 LEVEL 4 D 1/8" thick matte/non-glare acrylic subsurface printed or painted F 1/16" thick x 11 1/4" long rule, subsurface applied 4 N/A EXIT AT LEVEL 1 1 1/8" cap ht. F Symbol height matches cap ht. 1'-2" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 3" = 1' H2 78 Cleveland State University Sign Standards Manual SECTION 4 H3 1/2" Inside Stairwell Tactile Exit Emergency Exit Only 3/4" cap ht. 3/8" F 1 UL 1/32" thick exterior rated satin aluminum photo etched panel if placed on exterior Glass (by others) ALT DETAIL – EXTERIOR SCALE: 1" = 2" Interior sign 1/2" 1" cap ht. 3/8" EXIT 1/32" Rowmark raised text Exit 4 4 1/2" F 1 AC N/A 5'-0" D 1/8" thick matte/non-glare acrylic subsurface printed or painted 1/2" Exterior sign 1/8" Note: If signs are mounted on glass, place back-to-back to hide tape & adhesive. Mount with exterior-grade VHB tape (or Bron) & silicone adhesive—Tape should be as thin as possible so sign fits flush against glass. 1/32" 6" EXTERIOR ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 1" = 2" SECTION SCALE: 1" = 2" H3 79 Cleveland State University Sign Standards Manual SECTION 4 H4 Maximum Occupancy 1/8" 1/2" Maximum Occupancy 3/4" cap ht. 3/8" 4 1/2" 5/8" 5'-0" 200 1" cap ht. D 1/8" thick matte/non-glare acrylic subsurface printed or painted WALL F 1 UL Subsurface printed or applied vinyl 1/2" 6" TYPICAL ELEVATION (CONDITIONS WILL VARY) SCALE: 3/8" = 1' DETAIL SCALE: 1" = 2" SECTION SCALE: 1" = 2" H4 80 Cleveland State University Sign Standards Manual SECTION 4 H5 Vinyl Messages/Graphics Note: Cap ht. varies based on door size All text is white unless door color is light, use Refer to Sign Type B4 for typical CSU seal/ Department ID layout 2" cap ht. 1 UL L C L C C F 1 UL 1 1/4" Emergency Exit Only 1'-3" 5'-6" Active text area 75% width of full area on door, can accommodate up to 4 lines deep of text, left justify lists Emergency Exit Only DETAIL SCALE: 3" = 1' OP/PT Therapy Exam Rooms Speech & Hearing Clinic Staff & Students Only Active text area 75% width of full area on door, can accommodate up to 4 lines deep of text F 2" cap ht. 1 1/4" Note: This sign type is for text necessary to convey Life Safety messages. Cap ht. mat vary based on door size. Text to be white (C) on glass/ dark color door, (F) on light color door. OP/PT Therapy Exam Rooms Speech & Hearing Clinic 4 3/8" Space to separate messages 2" cap ht. EXTERIOR ELEVATION (CONDITIONS WILL VARY) SCALE: 1/2" = 1' Staff & Student Only 2 UL Use bold font to emphasize message DETAIL (ALT MESSAGE) SCALE: 1 1/2" = 1' H5 81 Cleveland State University Sign Standards Manual