Weschler Transducers AC & DC Transducers—Metal Case L • Accuracy: ±0.2% or 0.5% • Wide Variety of Input and Output Options • Rugged Metal Can Construction • 5 kV Transient Protection • Sizes: Can size 1: 3.976" L x 2.012" W x 4.096" H Can size 2: 5.236" L x 3.769" W x 4.717" H CLD001J AC CURRENT TRANSDUCER Output 0–1 mADC 4 mA–20 mADC 0–1 mADC 4 mA–20 mADC 0–1 mADC 4 mA–20 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC Transducer Type Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) Single (average sensing) 3 Inputs (average sensing) 3 Inputs (average sensing) Single (TRMS sensing) Single (TRMS sensing) Single (TRMS sensing) Single (TRMS sensing) Input 0–150 VAC 0–300 VAC 0–600 VAC 0–150 VAC 0–300 VAC 0–600 VAC 0–150 VAC 0–300 VAC 0–150 VAC 0–300 VAC 0–150 VAC 0–300 VAC Output 0–1 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC 0–1 mADC 0–1 mADC 0–1 mADC 0–1 mADC 4 mA–20 mADC 4 mA–20 mADC Frequency 45-55 Hz 45-65 Hz 55-65 Hz 375-425 Hz 45-55 Hz 45-65 Hz 55-65 Hz 375-425 Hz Input 120V 120V 120V 120V 120V 120V 120V 120V Aux. Power None 120 VAC 120 VAC 120 VAC None 120 VAC None 120 VAC 120 VAC Can Size 1 2 2 2 1 2 2 2 2 Part # ±0.5% CTA100JA CTD100JA CTA100JT CTD100JT CTA500JA CTD500JA CTA503JA CTA500JT CTD500JT Part # ±0.2% CTA100ZA CTD100ZA CTA100ZT CTD100ZT CTA500ZA CTD500ZA CTA503ZA CTA500ZT CTD500ZT Specifications on PAGE 98. TRANSDUCERS / SENSORS Input 0–1 AAC 0–1 AAC 0–1 AAC 0–1 AAC 0–5 AAC 0–5 AAC 0–5 AAC 0–5 AAC 0–5 AAC L Transducer Type Single (average sensing) Single (average sensing) Single (TRMS sensing) Single (TRMS sensing) Single (average sensing) Single (average sensing) Triple (average sensing) Single (TRMS sensing) Single (TRMS sensing) AC VOLTAGE TRANSDUCER Can Size 1 1 1 2 2 2 2 2 2 2 2 2 Part # ±0.5% ETA150JA ETA300JA ETA600JA ETD150JA ETD300JA ETD600JA ETA153JA ETA303JA ETA150JT ETA300JT ETD150JT ETD300JT Part # ±0.2% ETA150ZA ETA300ZA ETA600ZA ETD150ZA ETD300ZA ETD600ZA ETA153ZA ETA303ZA ETA150ZT ETA300ZT ETD150ZT ETD300ZT L Aux. Power None None None 120 VAC 120 VAC 120 VAC None None 120 VAC 120 VAC 120 VAC 120 VAC Specifications on PAGE 98. AC FREQUENCY TRANSDUCER—CAN SIZE “2” Part # ±1.0% FQA050J FQA055J FQA060J FQA400J FQD050J FQD055J FQD060J FQD400J Part # ±0.1% FQA050Z FQA055Z FQA060Z FQA400Z FQD050Z* FQD055Z* FQD060Z* FQD400Z* L Output 0-1 mA 0-1 mA 0-1 mA 0-1 mA 4-12-20 mADC 4-12-20 mADC 4-12-20 mADC 4-12-20 mADC Specifications on PAGE 98. *Accuracy is 0.2% 96 Weschler Transducers AC WATT TRANSDUCER—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A Output ±1 mADC ±1 mADC ±1 mADC ±1 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC 4 mA–20 mADC Aux. Power None None None None None None None None Part # ±0.5% WTB010J WTB020J WTB025J WTB030J WTD010J WTD020J WTD025J WTD030J Part # ±0.2% WTB010Z WTB020Z WTB025Z WTB030Z WTD010Z WTD020Z WTD025Z WTD030Z Part # ±0.5% VTB010J VTB020J VTB025J VTB030J VTD010J VTD020J VTD025J VTD030J Part # ±0.2% VTB010Z VTB020Z VTB025Z VTB030Z VTD010Z VTD020Z VTD025Z VTD030Z AC VAR TRANSDUCER—CAN SIZE "2" Output ±1 mADC ±1 mADC ±1 mADC ±1 mADC 4-12–20 mADC 4-12–20 mADC 4-12–20 mADC 4-12–20 mADC Aux. Power None None None None None None None None TRANSDUCERS / SENSORS AC WATT/VAR TRANSDUCER—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 3 ø 4-wire No. of Elements 1 element 2 element 21/2 element 3 element 1 element 2 element 21/2 element 3 element Rating 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A 120V/5A Output ±1 mADC x 2 ±1 mADC x 2 ±1 mADC x 2 ±1 mADC x 2 W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA W: 4–20mA, VAR: 4-12–20 mA Part # ±0.5% WVB010J WVB020J WVB025J WVB030J WVD010J WVD020J WVD025J WVD030J Part # ±0.2% WVB010Z WVB020Z WVB025Z WVB030Z WVD010Z WVD020Z WVD025Z WVD030Z Part # STD TC PFB010J PFB020J PFB030J PFF010J PFF020J PFF030J Part # Low TC PFB010Z PFB020Z PFB030Z PFF010Z PFF020Z PFF030Z Part # ±2° PAB010J PAB020J PAB030J PAF010J PAF020J PAF030J Part # ±1° PAB010Z PAB020Z PAB030Z PAF010Z PAF020Z PAF030Z AC POWER FACTOR—CAN SIZE "2" Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire Lag—Lead -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 -0.5 to 1.0 to +0.5 Connection 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire 1 ø 2-wire 3 ø 3-wire 3 ø 4-wire Phase Angle 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60° 60°–0–60° Output 1–0–1 mADC 1–0–1 mADC 1–0–1 mADC 4 –12–20 mADC 4 –12–20 mADC 4 –12–20 mADC AC PHASE ANGLE—CAN SIZE "2" NOTE: Also available in plastic foot-mounted or DIN rail. For ranges not listed, contact Weschler. 97 Output 1–0–1 mADC 1–0–1 mADC 1–0–1 mADC 4–12–20 mADC 4–12–20 mADC 4–12–20 mADC Weschler Transducers POWER FACTOR TRANSDUCERS SPECIFICATIONS - ALL AC MODELS Output Response Time Output Ripple Isolation External Span Adjustment Surge Withstand Insulation Resistance Operating Temperature 0-1 or ±1mADC into 10kΩ max., 10VDC compliance 4-20mADC into 750Ω max., 15VDC compliance <400ms (0-99% of output) 0.5% of span, peak-to-peak max 2500VAC input to output, power & case 2000VAC aux. power to output & case 500VAC output to case Zero: ±1% min; Span: ±2% min IEEE472/ANSI C37.90.1-1989, JIS C111 (5kV, 1.2 x 50µs) >10MΩ@500VDC input/output/power/case -20°C to 60°C; 0-90% RH non-condensing Specifications same as Combined Watt/VAR Models except: Accuracy ±0.01 power factor Temperature Drift ±500ppm/°C of span, suffix J models ±150ppm/°C of span, suffix Z models Low Current Detect <4% Influences (% of span) <1% for voltage, <2% for current Options for PF Models 1 AAC Current Rated 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power AC PHASE ANGLE TRANSDUCERS AC CURRENT & VOLTAGE TRANSDUCERS Current Models Input Burden Overrange <0.2VA 200% of rated input continuous; 1000% of rated input for 5 sec Voltage Models Input Burden 150VAC: <0.8VA; 300 VAC: <1.6VA (TRMS) 150VAC: <1.8VA; 300 VAC: <3.6VA (Avg. Sensing) Overrange 120% of rated input continuous Temperature Drift ±250ppm/°C of span, 0.5% models ±140ppm/°C of span, 0.2% models Options (specify when ordering) 50Hz, 50/60Hz or 400Hz operation (60Hz standard) 230VAC, 24VDC* or 48VDC* Auxiliary Power (*average sensing models only) Input Burden Voltage Input Range Voltage Overrange Current Input Range Current Overrange Output Calibration Temperature Drift Influences (% of span) Voltage: <0.5VA per element @120V Current: <0.2VA per element 100-135VAC, input powered 0.5% models 85-135VAC, input powered 0.2% models 0-120% of rated input, auxiliary powered models 150% of rated input continuous (aux. powered only) 10-200% of rated input with accuracy 200% continuous, 1000% for 5 seconds 120VAC/1A = 0-100 watts/element 120VAC/5A = 0-500 watts/element ±250ppm/°C of span, 0.5% models ±80ppm/°C of span, 0.2% models <0.5% for PF, phase interaction or current imbalance COMBINED AC WATT/VAR TRANSDUCERS Input Burden Voltage Input Range Voltage Overrange Current Input Range Current Overrange Temperature Drift Influences (% of span) Voltage: <0.5VA per element Current: <0.2VA per element 100-135VAC, input powered 0.5% models 85-135VAC, input powered 0.2% models 0-120% of rated input, auxiliary powered models 150% of rated input continuous (aux. powered only) 10-200% of rated input with accuracy 200% continuous, 1000% for 5 seconds ±250ppm/°C of span, 0.5% models ±80ppm/°C of span, 0.2% models <0.5% for PF, phase interaction or current imbalance Options for Watt, VAR & Watt/VAR Models 50Hz or 400Hz operation (60Hz standard) 1AAC Current Rated 240VAC Voltage Rated 480 VAC Voltage Rated (not available on 0.2% units) 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power Special Calibration to Customer PT & CT Options for Phase Angle Models 50Hz or 400Hz operation (60Hz standard) 1AAC Current Rated 120VAC, 240VAC, 24VDC or 48VDC Auxiliary Power Full Scale = Lagging Phase Angle ±90° Phase Angle FREQUENCY TRANSDUCER Input Burden Voltage Input Range TRANSDUCERS / SENSORS AC WATT & VAR TRANSDUCERS Specifications same as Combined Watt/VAR Models except: Temperature Drift ±500ppm/°C of span, suffix J models ±80ppm/°C of span, suffix Z models Influences <0.5° for voltage, <1° for current <0.1VA @120V 100-135VAC, input powered models ±20% of rated voltage, aux. powered models ±250ppm/°C of span, suffix J models ±50ppm/°C of span, suffix Z models Fundamental through 9th harmonic Temperature Drift Harmonics Options for Frequency Models 240 Volt Input 24VDC or 48VDC Aux. Power (0.2% models only) 1-0-1 mADC Output DC TO DC ISOLATION TRANSDUCERS Input Burden Output Compliance Accuracy (>10% of range) Response Time Calibration Adjustments Temperature Range Isolation Surge Withstand Auxiliary Power <1 mA 10VDC ±0.5% of FS 500ms (0-99%) ±5% (zero & FS) 0-40°C, 20-90% RH non-condensing 2600VAC input to output, power & case 1000VAC aux power to output & case 1000VAC output to case IEEE472/ANSI C37.90.1-1989 SWC 120VAC ±10%, 2VA DC TO DC ORDERING INFO Input 0-1mADC 0-1mADC 0-1mADC 0-50mVDC 0-50mVDC 0-50mVDC Output 4-20mADC 0-1mADC 0-10VDC 4-20mADC 0-1mADC 0-10VDC Aux. Power 120VAC 120VAC 120VAC 120VAC 120VAC 120VAC Case Size 2 2 2 2 2 2 Part # CLD001J CLD002J CLD003J CLD101J CLD102J CLD103J 98