Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load to the emergency power source when it detects the normal power source under/over voltage, under/over frequency, or phase loss. The switch has three operational positions (Source I, Center-off, Source II). The two sources are isolated when the switch is in the centeroff position. A center-off position locking mechanism is also provided. Application The Series 230 transfer switch is rated up to 800A and is available from 220 to 415 volts for both 50 and 60 Hz, single and three phase. Typical applications include commercial and residential buildings, hospitals, telecom, subway and transportation, data centers, military and fire pumps. Parameter Rated Operational Current Ie (A) Rated Insulation Voltage Ui (V) Rated Impulse Withstand Voltage Uimp (kV) 16 32 63 80 100 125 160 200 225 250 315 400 500 630 800 1000 1000 1000 1000 8 8 12 12 12 800 220, 230, 240, 380, 400, 415 Rated Operation Voltage Ue (V) 50 / 60 Rated Frequency (Hz) 2,4 Poles 2, 3, 4 Rated Short-Time Withstand Current Icw (kA, RMS) 6 (0.03s) 10 (0.1s) 15 (0.1s) 25 (0.1s) 40(0.1s)/ 20(1s) Rated Short-Circuit Making Capacity Icm (kA, PEAK) Withstand and Close-On Rating Iq (kA) 8 17 31.5 65 80 When Used With Current Limiting Fuses 65 65 200 200 200 When Used With Specific Circuit Breakers 15 50 150 150 80 10 Ie Making and Breaking Capacity 10,000 Mechanical Operation Performance (cycles) AC-32A, AC-33B Utilization Category Operation Voltage range (AC) Ue=220V / 230V / 240V / 380V / 400V Ue= 415V Wiring Way Front Separate Lock Mechanism 1 (0.7~1.15) Ue Class A EMC Class Auxiliary Contact (Optional) (0.7~1.2) Ue 125~300V (L-N) Standard 4 contacts maximum 8 contacts maximum Series 230 Automatic Transfer Switch Product Features Performance Features Switching Mechanism Meets or exceeds the requirements of the following regulatory agencies •Automatic, manual and remote operation are available • EN60947-6-1/IEC60947-6-1: Transfer Switching •Unique contacts design limits contact bounce • EN60947-3/IEC60947-3: Suitable for Isolation •Unique clutch design makes manual operation easy and low force • EN55022: Radiated and Conducted Emission, Class A • EN61000-3-2: Harmonic Current Emission, Class A • EN61000-3-3: Limits of Voltage fluctuation and Flicker • EN 61000-4-5: Immunity to Surge • EN 61000-4-4: Immunity to Electrical Fast Transient • EN61000-4-2: Immunity to Electrostatic Discharge • EN61000-4-3: Immunity to Radiated Electric Fields • EN 61000-4-6: Immunity to Continuous Conducted Interference Structure •Electrical and mechanical interlocks prevent two sources from connecting simultaneously •Innovative motor circuit protection ensures precision operation •Cast steel bevel gear mechanism provides high transmission efficiency, and extends operating life Controller •Different Operating Modes (Source I priority / No Source priority) •C300 and C2000 can work with an external 24VDC power supply •High frequency switching power supply, and wide power voltage range •PC Class ATS •Data (e.g. Event log, Setting, etc) remains intact if power is lost •High ability to withstand lightning strikes (40kA 8/20μs) •Intelligent fault diagnostics enable selfprotecting motor feature •Simple reliable mechanism, compact and stylish appearance •RS485 communication interface is available •Modular design, convenient operation, easy maintenance •Priority Source Swap •Three operating positions. Both sources can be isolated in a center-off position Arc Extinguish •The utilization categories are AC-32A, AC-33B, and the ability to withstand and break is10 Ie •Rotating dual contact design extinguishes the arc quickly and effectively •Arcing contacts and main contacts are separate; main contacts are protected from arc damage •Wiping-action contacts are self cleaning •High short-circuit closing ratings 2 Make Life and Business More Reliable By Using ASCO Series 230 Transfer Switch Ordering Information To order an ASCO Series 230 Automatic Transfer Switch, complete the following catalog number: E2ADTL B3 Frame size Poles A2ADTL 16 ~ 80A Frame B1: 2 Poles (L-N) (2-wire with Neutral) 0800 D X 0 1H Controller Options Enclosure Optional Accessories H Amperes Voltage Continuous Code Rating 0016, 0032 D 220V B C300* 0063, 0080 02: 2 poles (L-L) C2ADTL 200 ~ 250A Frame (2-wire without Neutral) 0100, 0125 E 230V D C1000 F 240V E C2000 D2ADTL 315 ~ 400A Frame B2: 3 Poles (3-wire with Neutral) E2ADTL 500 ~ 800A Frame 03: 3 Poles (3- wire without Neutral) 0160, 0200 H 380V 0225, 0250 J 0315, 0400 K 415V B2ADTL 100 ~ 160A Frame 0500, 0630 B3: 4 Poles (4-wire with Neutral ) 0800 * The A2ADTL frame is only available with the embedded C300 controller 3 400V Insert “X” O Open type 132JA ~ 132JC If optional B2ADTL Frame BusBar accessories C IP20 are required 132A ~ 132F Q IP54 Auxiliary Contacts 72D C300, C1000 with RS-485 1H C2000 with Energy Storage Optional Accessory Model Description and Order Information B2ADTL Frame Bridging Bus Bar 132 J A Poles A: 2 poles (02356097) B: 3 poles (02357091) C: 4 poles (02355942) 4 pole Bridging Busbar Function Code 132J: Bridging Busbar For example: 132JC , means Bridging Busbar for a 4 pole transfer switch Auxiliary Contacts 132 A A Auxiliary Contact Quantity BLANK: 1 contact A: 2 contacts B: 3 contacts C: 4 contacts Function Code 132A-132F: Auxiliary Contact Auxiliary Contact For example: 132BA , means 2 sets of contacts, which close when the ATS transfers to the Source II position. 4 Auxiliary Contact Definition 132A-132C : The auxiliary contacts can be used to indicate position with the CLOSE contact, see Schematic 1. 132D-132F: The auxiliary contacts can be used to indicate position with the OPEN contact, see Schematic 2. Position of The Transfer Switch Auxiliary Contact Function Code 132A 132B 132C Position of The Transfer Switch I I O O II II Auxiliary LAP1F100 (16021426) Contact LAP1F010 Code (16021427) √ √ - - - √ Auxiliary LAP1F100 (16021426) Contact LAP1F010 Code (16021427) Auxiliary Contact Mounting Position Auxiliary Contact Mounting Position (only showing C2ADTL, D2ADTL, E2ADTL). (only showing C2ADTL, D2ADTL, E2ADTL). 72D C300 or C1000 Controller with RS-485 interface A RS485 interface installed in the C300 or C1000 controller to enable serial communications, supporting MODBUS protocol. This Accessory can only be installed in the factory. Use accessory code 72D when ordering this function. 1H C2000 Controller with energy storage The optional controller with energy storage (Accessory 1H) has an added feature to switch the transfer switch to the center-off position during Source I and Source II failure at the same time. The controller will remain in center-off until either Source I or Source II power is restored and voltage and frequency are both stable. This optional feature can work in Source I Priority and No Source Priority operating modes. This feature is available only after the controller has been powered by AC input for at least10 minutes to charge a capacitor. This Accessory can only be installed in the factory. Use accessory code 1H when ordering this function. 5 Auxiliary Contact Function Code 132D 132E 132F - - √ √ √ - Avoid Losing Critical information When Power is Lost Series 230 Dimensions and Weight A2ADTL Frame A 108mm(4.25) 120mm(4.72") 18") m(Ă0. Ă4.5m 171mm(6.73") A 18mm(0.71") Unit: mm(inch) C 2P 4P 216.0 252.0 1.6 2.0 A2ADTL Size (mm) B 45mm(1.77") 110mm(4.33") 124mm(4.88") 121.3mm(4.77") 107mm(4.21") 96mm(3.78") 93mm(3.66") 20.5mm(0.81") Weight (kg) Note: unit must be installed in the cabinet using a DIN35 rail B2ADTL Frame 214mm(8.4") 184mm(7.2") 126mm(5.0") 29mm(1.1") 117mm(4.6") 104mm(4.1") 78mm(3.1") 112mm(4.4") 27mm(1.1") 15mm(0.6") A Unit: mm(inch) B2ADTL Size (mm) Weight (kg) A 2P 3P 4P 241.0 349.0 349.0 2.6 2.8 2.8 Note: unit must be installed in the cabinet using a DIN35 rail 6 168mm(6.6") 12.5mm(0.5") C2ADTL Frame 20mm(0.8") 126mm(5.0") 150.5mm(5.9") 130mm(5.1") 116mm(4.6") 100mm(3.9") 9mm(0.4") 6mm(0.2") 34mm(1.3") 177mm(32.8") 7.5mm(0.3") 9mm(0.4") 50mm(2.0") 128mm(5.0") 23.5mm(0.9") 172mm(6.8") 194mm(7.6") 182mm(7.2") Ø6mm(Ø0.2") C B A 2P 3P 4P A 251.0 285.0 319.0 B 236.0 270.0 304.0 C 68.0 102.0 136.0 4.6 5.2 5.8 C2ADTL Size (mm) Unit: mm(inch) Weight (kg) 15.5mm(0.6") D2ADTL Frame 120mm(4.7") Ø7mm(Ø0.3") 206mm(8.1") 44mm(1.7") 10mm(0.4") B A 2P 3P 4P A 317.0 361.0 405.0 B 297.0 341.0 385.0 C 103.0 147.0 191.0 8.6 9.8 11.0 D2ADTL Size (mm) Weight (kg) 7 25mm(1.0") 10mm(0.4") 140mm(5.5") 120mm(4.7") 186mm(7.3") 158mm(6.2") 144mm(5.7") 2.5mm(0.1") 199mm(7.8") 52mm(2.0") 228mm(9.0") 215mm(8.5") 173mm(6.8") C Unit: mm(inch) ASCO Power Transfer Switch Solutions for Powerful Peace of Mind 8mm(0.3") E2ADTL Frame 10mm(0.4") 174mm(6.9") 195mm(7.7") 290mm(11.4") 265mm(10.4") 208mm(8.2") 160mm(6.3") Ø9mm(Ø0.4") 228mm(9.0") 65mm(2.6") 14mm(0.6") 13mm(0.5") 45mm(1.8") C 19mm(0.7") 226mm(8.9") 57mm(2.3") 165mm(6.5") 240mm(9.5") 252mm(10.0") 180mm(7.1") B A 2P 3P 4P A 384 449 514 B 357 422 487 C 146 211 276 14 17 20 E2ADTL Size (mm) Unit: mm(inch) Weight (kg) Shipping Dimensions and Weights (Including TS and controller, without options) Frame Width (mm) Height (mm) Depth (mm) 2P 4P A2ADTL 310 170 175 1.9 2.3 B2ADTL 602 220 C2ADTL 602 D2ADTL E2ADTL Weight (kg) with C300 Weight (kg) with C1000 Weight (kg) with C2000 2P 3P 4P 2P 3P 4P 267 4.9 5.5 5.7 5.2 5.8 6.0 335 227 8.9 9.5 10.1 9.2 9.8 10.4 650 350 300 13.0 14.5 16.0 13.4 14.9 16.4 767 350 352 16.0 19.0 22.0 16.5 19.5 22.5 * All information is subject to change, for the latest information please contact ASCO sales team. 8 Series 230 Controller Feature Comparisons C300 Controller C1000 Controller Voltage and Frequency Sensing Voltage and Frequency Sensing Voltage and Frequency Sensing • Single phase under and over voltage settings on Source I and Source II • Single phase under and over voltage settings on Source I and Source II • Phase loss sensing on Source I and Source II • Phase loss sensing on Source I and Source II •Under and over frequency settings on Source I and Source II •Under and over frequency settings on Source I and Source II •3-Phase under and over voltage settings on Source I and Source II •Under and over frequency settings on Source I and Source II •Voltage unbalance detection between phases Time Delays Time Delays •Time delay sensing accuracy is ±1% •Time delay sensing accuracy is ±1% •Transfer time delay can be set manually •Transfer time delay can be set manually Controller Display and Keypad Controller Display and Keypad •LED display •LED display •Touch key for clearing alarm and manual operation •Touch pad for clearing alarm and manual operation •Switch position indicator lights •Switch position indicator lights •Source acceptability indicator lights •Source acceptability indicator lights Operating Modes •LCD display •Touch pad for programming the features and settings •Switch position indicator lights •Source acceptability indicator lights Operating Modes •Automatic and manual operation available Operating Modes •Automatic and manual operation available •Source I Priority/ No Source Priority •Priority Source Swap •Source I Priority/ No Source Priority •Priority Source Swap Center-off with time delay and center-off with protection Center-off with time delay and center-off with protection •The center-off time delay can be set to avoid large current inrush to inductive loads •The center-off time delay can be set to avoid large current inrush to inductive loads •Center-off with protection is available to protect critical loads (e.g. Fire Pump) •Center-off with protection is available to protect critical loads (e.g. Fire Pump) Remote Control and Communication Remote Control and Communication •Can control switch remotely (e.g. Position Control, Time Delay, etc.) •Can control switch remotely (e.g. Position Control, Time Delay, etc.) •Fire control signal input (24VDC) •Fire control signal input (24VDC) Power Supply of Controller Power Supply of Controller • Operation Voltage (VAC): 220/ 230/ 240 •Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 • C300 has ability to work with 24VDC power supply 9 C2000 Controller Time Delays •Time delay can be set by operating parameter setting menu •Time delay sensing accuracy is ±1% •Time delay can be set under different working modes •Transfer time delay can be set manually Controller Display and Keypad •Automatic and manual operation available •Source I Priority/ No Source Priority •Priority Source Swap Center-off with time delay and center-off with protection •The center-off time delay can be set to avoid large current inrush to inductive loads •Center-off with protection is available to protect critical loads (e.g. Fire Pump) Events Display •Event log displays: 100 most recently logged events with time and date of each event, event type and event reason Remote Control and Communication •Uses RS485 interface, and supports MODBUS Communication •Can control switch remotely (e.g. Position Control, Time Delay, etc.) •Fire control signal input (24VDC) Power Supply of Controller •Operation Voltage (VAC): 220/ 230/ 240/ 380/ 400/ 415 •C2000 has ability to work with 24VDC power supply 24-hour Protection No Matter When Trouble Strikes Rated Operation Voltage Ue(V) Rated Frequency (Hz) Display Indicator Source(I,II) Available ATS Position Control Mode Manual/Automatic Source I Priority No Source Priority Remote Control Unique Control Funcation Remote control Priority (1) Priority Source Swap Center-off with protection when Source I and II are lost (3) Diagnosis fault intelligent with self -protection function Source Sensing Setting Voltage Sensing(4) Frequency Sensing Power loss Phase loss (5) Undervoltage Overvoltage (6) Overfrequency Transfer Underfrequency Transfer Time Delay Setting Override Momentary Source Outage Transfer to Source II Transfer to Source I Engine Cooldown Center-Off Position Delay Others RS-485 Additional 24V DC Power Input Generator Control Signal Output Fire Control Signal Input Alarm Auxiliary Contact Event Log Display Type Installation C300 C1000 C2000 220/230/240 50/60Hz 220/230/240/380/400/415 50/60Hz 220/230/240/380/400/415 50/60Hz (2) Optional L1-N,L2-N,L3-N L1,L2,L3 65%, 70%, 80%, 85% 120% / OFF 115% 85% L1-L3 L1,L3 70%, 85% 120% / OFF 115% 85% L1-L2,L2-L3,L3-L1 L1,L2,L3 70% 〜 98% 102% 〜 120% / OFF 102% 〜 115% 85% 〜 98% 1s 0s, 5s, 30s, 5min 1s, 30s, 5min, 30min 2min OFF / 5s 1s 0 〜 5min 1s 〜 30min 2min OFF / 5s 0 〜 3s 0 〜 5min 0 〜 30min 0 〜 60min 0 〜 5s Optional Optional Optional Optional LED DIN rail installation and Panel installation LED DIN rail installation and Panel installation Optional LED+LCD Panel installation :Yes, Standard; Blank: Not Available/ Not Applicable Remarks: 1. Only available for source priority mode 2. C1000 controller with priority swap function requires special soft ware to be field installed 3. Need to use controller with energy storage (Accy 1H) 4. For C300 controller, Source II Voltage sensing is only on L1 5. For C300 controller, Source II Phase loss sensing is only on L1 6. When the controller is used on 415V, its Overvoltage Droupout is 115% both on Source I and Source II 10 C300 Controller Port Function Description Accessory 72D Optional RS485 Port 24V 24V DC Power Input 11 RS485 24V Generator Start Alarm GEN ALM Fire Control Transfer to Input Position O FIRE DI 1 Transfer to Position I Transfer to Position II Push to test RS485 DI 2 DI 3 DI 4 485 Port 72D C1000 Controller Port Function Description Accessory 72D Optional RS485 Port RS485 24V Generator Start Alarm Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II RS485 GEN ALM FIRE DI5 DI6 DI7 485 Port X3 User Terminal 72D X4 C1000 CONTROLLER X1 Power Terminal X2 Control Terminal Power and Voltage Detection Transfer Switch Position Detection and Transfer Control To Transfer Switch X1 To Transfer Switch X2 12 C2000 Controller Port Function Description 24V Alarm ALM O I II TS Position DO1 DO2 DO3 Generator Start RS485 GEN 485 PORT Fire Control Transfer to Transfer to Transfer to Input Position O Position I Position II FIRE DI5 DI6 DI7 X4 User Terminal C2000 CONTROLLER X1 Power Terminal Power and Voltage Detection To Transfer Switch X1 X2 Control Terminal X3 User Terminal Transfer Switch Position Detection 24V DC and Transfer Control Power Input To Transfer Switch X2 24V Lost Power X5 Capacitor. Output Energy storage output Accessory 1H Optional Built-In Capacitor used as a (rechargeable) one-time motor-control transfer after complete power loss. This accessory also requires a different connector board on the Transfer Switch Unit. 13 1H Critical Loads Demand ASCO Controller Dimensions and Weight* C1000 Controller (With or Without optional 72D Accessory) 80.7 58.7 93.5 111.5 46.2 47±0.5 94±0.5 Panel Opening Dimensions Weight: 0.74kg Unit: mm(inch) C2000 Controller 191±1 Source I 86 Source II 134±1 142 132 80 Run Auto Alarm UP Esc Transfer Switch Position 197 Enter Down 189 Panel Opening Dimensions Weight: 1kg Unit: mm(inch) 14 Critical Loads Demand ASCO C2000 Controller with Energy Storage (Accessory 1H) 128.7 122.2 189.0 Run Auto Alarm Source I Source II 132.0 142.0 UP Esc Transfer Switch Position Enter Down 197.0 Weight: 1.64kg Unit: mm(inch) *Not Shipping weight, Actual unit weight 15 About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at: www.emersonnetworkpower.com About Emerson Emerson (NYSE: EMR), based in St. Louis, Missouri (USA), is a global leader in bringing technology and engineering together to provide innovative solutions for customers in industrial, commercial, and consumer markets around the world. The company is comprised of five business segments: Process Management, Industrial Automation, Network Power, Climate Technologies, and Commercial & Residential Solutions. Sales in fiscal 2013 were $24.7 billion. For more information, visit: www.emerson.com Official Wechat Official Weibo Legal statement: While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. Emerson Network Power Co., Ltd. Pre-sales hotline: After-sales hotline: Address: Block B2 Nanshan Park No.1001 Xueyuan Road Nanshan Dist. Shenzhen, 518055 China China Telephone: 86-755-86010808 Postcode: 518055 400-887-6526 400-887-6510 www.emersonnetwork.com.cn Emerson Network Power, ASCO, the Emerson Network Power logo and ASCO logo are trademarks and service marks of Emerson Electric Co. ©2015 Emerson Electric Co. E-X6216497-0915