QUICK SPEC POLYURETHANE FOAM - DIATHON NOTE: The following “Quick Spec” is an abbreviated specification and is not meant to replace the detailed specification. Read the entire 3-Part CSI System Specification prior to starting the project. Method Spray, roller, or brush Requirements Moisture survey required. Roof must be clean, dry, and tight. Adhesion test required to ensure proper adhesion to substrate(s). Apply at 50°F (10°C) and rising with no rain or freezing temperatures in forecast for 24 hours. Application Instructions 1. 2. 3. Conduct moisture survey and remove/replace all wet areas. Repair penetrations, flashings, curbs, and terminations with like materials. Power-wash roof. It is recommended to use United Cleaning Concentrate (UCC) to clean the roof. Allow roof to completely dry. For recoat applications: Treat all splits, roof penetrations, drains, and curbs. Apply coating per the chart below: 4. 5. POLYURETHANE FOAM DIATHON® Base Coat Product Base Product Gal/Sq (Choose one) 1st Coat Coating 2nd 3rd Coat Coat Total 4th Coat Coating Gal/Sq Gal/Sq DFT* Warranty Limited Emerald Diamond Warranty Pledge Pledge Diathon® Base 1.50 Diathon® Diathon® QS 1.50 1.00 2.50 4.00 46 Yes Yes No Diathon® Base 1.50 Diathon® HT 1.00 1.25 2.25 3.75 44 Yes Yes No Diathon® Base 1.50 Diathon® Diathon® QS 1.50 1.00 1.00 3.50 5.00 55 Yes Yes No Diathon® Base 1.50 Diathon® HT 1.00 1.00 1.00 3.00 4.50 51 Yes Yes No Diathon® Base 1.50 Diathon® Diathon® QS 1.50 1.00 1.00 4.50 6.00 63 Yes Yes No Diathon® Base 1.50 Diathon® HT 1.25 1.25 1.25 3.75 5.25 57 * Dry Film Thickness (DFT) uses the average % solids by volume between the two coatings, is rounded to nearest Yes Yes No 10 Year 15 Year 20 Year 1.00 mil, and is theoretical. Actual DFT will vary dependent on substrate profile, application technique & waste factor). 2/16