Florida Building Code Online BCIS Home Log In User Registration Page 1 of 2 Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL16739-R8 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (973) 872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley (current) Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Single Ply Roof Systems Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/16/2016 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL16739_R8_COI_2015_01_COI_Nieminen.pdf Referenced Standard and Year (of Standard) Standard Year ASTM D4434 2009 TAS 110 2000 TAS 114 2011 Equivalence of Product Standards http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6... 2/12/2016 Florida Building Code Online Page 2 of 2 Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/16/2015 Date Validated 12/16/2015 Date Pending FBC Approval 12/19/2015 Date Approved 02/10/2016 Summary of Products FL # Model, Number or Name Description 16739.1 EverGuard PVC Single Ply Roof Systems Thermoplastic single ply roof systems Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +N/A/-502.5 Other: 1.) The design pressure herein pertains to one system. Refer to ER Appendix for all systems and maximum design pressures. 2.) Refer to ER Section 5 for Limits of Use. Installation Instructions FL16739_R8_II_2015_12_FINAL_A1_ER_GAF_PVC_HVHZ_FL16739R8.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL16739_R8_AE_2015_12_FINAL_ER_GAF_PVC_HVHZ_FL16739R8.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6... 2/12/2016 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street, Unit 13 Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 Evaluation Report 01506.12.14-4-R9 FL16739-R8 Date of Issuance: 12/19/2013 Revision 9: 12/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted herein. DESCRIPTION: EverGuard® PVC Single-Ply Roof Membrane Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “Engineer Evaluated, FBC (HVHZ)” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 34-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 12/15/2015. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems ® Compliance Statement: EverGuard PVC Single-Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code, HVHZ through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. 3. STANDARDS: Section Property Standard Year 1523.6.2 TAS 110 TAS 110 Testing Requirements System Performance Physical Properties TAS 110 TAS 114 ASTM D4434 2000 2011 2009 Entity Examination Reference Date ATI (TST1558) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) FET (TST7393) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) Physical Properties TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties FM 4470 / 4474 FM 4470 / 4474 TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 52825.01-106-31 06-047 07-001 07-002 07-007 07-029 07-031 08-031 11-057 11-058 11-059 11-060 11-061 11-062 11-063 11-066 12-005 12-006 12-007 12-009 12-010 12-011 12-021 12-022 12-017 12-020 12-027 12-028 12-032 11-015-R1 11-018-R1 11-022-R1 F35940.10.11-2-R2 F35940.12.11-R2 F42130.06.13 F42130.06.13-1 F42130.09.13 GAF-SC8580.14 GAF-SC8580.14 08-050182 3003956 3003955 3014692 3024709 06/15/2005 12/21/2006 01/12/2007 01/12/2007 01/19/2007 03/08/2007 05/09/2007 05/05/2008 09/30/2011 10/03/2011 10/04/2011 10/05/2011 10/06/2011 10/07/2011 10/08/2011 11/21/2011 04/09/2012 04/09/2012 04/10/2012 04/20/2012 04/20/2012 04/20/2012 04/26/2012 04/26/2012 05/07/2012 05/08/2012 05/22/2012 05/22/2012 08/23/2012 08/29/2012 08/29/2012 08/29/2012 02/27/2012 02/27/2012 06/05/2013 06/05/2013 09/13/2013 03/25/2015 07/20/2015 06/26/2008 02/18/2000 03/05/2002 08/05/2003 10/21/2005 REFERENCES: Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.12.13-4-R9 FL16739-R8 Revision 9: 12/15/2015 Page 2 of 5 Entity Examination Reference Date FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) IRT (TST5296) MTI (TST2508) MTI (TST2508) MTI (TST2508) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) UL, LLC. (QUA9625) UL, LLC. (QUA9625) UL, LLC. (QUA9625) UL, LLC. (QUA9625) FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 TAS 114 ASTM D4434 ASTM D4434 ASTM D4434 Physical Properties Component Performance Component Performance Component Performance Component Performance FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 FM 4470 / TAS 114 Quality Control Quality Control Quality Control Quality Control 3023368 3028606 3026964 3031127 3033126 3034394 3037879 797-07043-267 3044862 3044914 3045789 3046328 3041769 3046403 797-07886-267 797-07849-267 3046054 3047606 3048122 797-08217-267 3047237 3047636 797-09495-267 797-09594-267 797-09892-267 04-006 NX21J0A NX21J0B NX21J0C GAF-373-02-01 GAF-462-02-01 GAF-462-02-02 GAF-462-02-03 GAF-462-02-04 GAF-457-02-02 GAF-457-02-04 GAF-457-02-06 GAF-457-02-07 GAF-457-02-08 GAF-510-02-02 GAF-515-02-01 GAF-515-02-03 GAF-516-02-03 GAF-525-02-02 GAF-525-02-03 GAF-462-02-07 GAF-462-02-08 GAF-462-02-09 GAF-462-02-10 GAF-462-02-11 GAF-538-02-03 ML File No. R1306, R9228 ML File No. R1306, R21864 Inspection Report, PA Inspection Report, NJ 03/20/2006 02/23/2007 07/25/2007 10/01/2007 07/11/2008 02/27/2009 02/04/2010 01/16/2012 05/11/2012 06/18/2012 07/12/2012 09/13/2012 09/27/2012 09/28/2012 11/21/2012 12/03/2012 12/21/2012 02/26/2013 04/29/2013 05/01/2013 07/15/2013 08/08/2013 05/27/2014 06/24/2014 08/12/2014 02/16/2004 06/01/2011 07/20/2011 06/01/2011 10/15/2012 11/15/2013 11/18/2013 11/18/2013 11/18/2013 01/20/2014 01/24/2014 01/24/2014 01/24/2014 01/24/2014 04/08/2014 05/13/2014 05/13/2014 05/13/2014 06/23/2014 06/23/2014 07/01/2014 07/01/2014 07/01/2014 07/01/2014 07/01/2014 08/13/2014 01/27/2015 03/11/2015 08/07/2015 11/12/2015 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.12.13-4-R9 FL16739-R8 Revision 9: 12/15/2015 Page 3 of 5 4. PRODUCT DESCRIPTION: This Evaluation Report covers EverGuard® PVC Single-Ply Roof Membrane Systems installed in accordance with GAF published installation instructions and the Limitations / Conditions of Use herein. ® ® ® EverGuard PVC-50, EverGuard PVC-60 and EverGuard PVC-80 membranes are nominal 50-mil (1.3 mm), 60-mil (1.5-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (PVC) roof covers, available in 81 and 40.5inch wide rolls. ® EverGuard PVC Smooth membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, polyester scrim reinforced, thermoplastic (PVC) single-ply roof membranes, available in 120 and 60-inch wide rolls. ® EverGuard PVC XK membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic ® fiber reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membranes, available in 120 and 60-inch wide rolls. ® EverGuard PVC XK Fleeceback membranes are nominal 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic fiber ® reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membrane with a nonwoven polyester felt backing, available in 120 and 76-inch wide rolls. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 Fire classification is not part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.4 The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’ conditions under TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the AHJ. 5.5 Fastener spacing for mechanical attachment of insulation, anchor/base sheet or membrane is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing – prepared, signed and sealed by a qualified design professional – may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or RAS 137. 5.5.1 If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5.6 For systems where specific lightweight insulating concrete is referenced, consult the current HVHZ product approval documentation for specific deck construction and limitations. For systems where specific lightweight insulating concrete is not referenced, the minimum design mix shall be for minimum 300 psi cellular material. 5.7 For recover installations, the existing roof shall be examined in accordance with FBC 1521. 5.8 Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137 by a qualified design professional. This extrapolation is not permitted for systems marked with an asterisk*. 5.9 All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.12.13-4-R9 FL16739-R8 Revision 9: 12/15/2015 Page 4 of 5 5.10 For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners). 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with TAS 124. 5.12 All products listed herein shall have quality assurance audit in accordance with the Florida Building Code and Florida Administrative Code Rule 61G20-3. 6. INSTALLATION: ® 6.1 EverGuard PVC Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per TAS 114 has already been applied). Refer to FBC 1620 and RAS 128 for determination of design wind loads. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. 7. QUALITY ASSURANCE ENTITY: UL, LLC. – QUA9625; (314) 578-3406; k.chancellor@ul.com - THE 34-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.12.13-4-R9 FL16739-R8 Revision 9: 12/15/2015 Page 5 of 5 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description 1A Wood New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Page 4 1B Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1C Wood New, Reroof (Tear-Off) or Recover C-2 Plate-Bonded Roof Cover 5 1D Wood New, Reroof (Tear-Off) or Recover D-1 Mechanically Attached Roof Cover 2A-1 Steel or Conc. New, Reroof (Tear-Off) or Recover B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 2A-2 Steel or Conc. New, Reroof (Tear-Off) or Recover B-2 Mechanically Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover 2B-1A Steel or Conc. New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 2B-1B Steel or Conc. New, Reroof (Tear-Off) or Recover C-1A Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover 14 2B-2 Steel or Conc. New, Reroof (Tear-Off) or Recover C-2 Mechanically Attached Insulation, Plate-Bonded Roof Cover 15 2C Steel New, Reroof (Tear-Off) or Recover D-1 Mechanically Attached Roof Cover 3A Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 3B Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 22 4A LWIC New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 23 4B LWIC New or Reroof (Tear Off) E Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 4C LWIC New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 5A CWF New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6A Gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 6B Gypsum Reroof (Tear-Off) B-1 Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 6C Gypsum Reroof (Tear-Off) C-1 Mechanically Attached Insulation, Bonded Roof Cover 6D Gypsum Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 7B Concrete Recover F Non-Insulated, Bonded Roof Cover 5 6-10 11 12-13 16 17-22 23 24-25 26 27 27-29 30 30 31-34 34 The following notes apply to the systems outlined herein: 1. The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’ conditions under TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the AHJ. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. ¾-inch plywood penetration or minimum 1-inch wood plank embedment. Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only). Minimum ¾-inch steel penetration, engage the top flute of the steel deck. Concrete Deck: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP 3S. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 1 of 34 3. Unless otherwise noted, insulation may be any one layer or combination of FBC (HVHZ) Approved polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. A separator is required when using polystyrene insulation with smooth-backed EverGuard® PVC membranes (EverGuard® PVC XK, EverGuard® PVC Smooth and EverGuard® PVC-50; 60; 80). Refer to GAF published installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuard® roofing systems: Insulation: FBC HVHZ approved Expaned polystyrene (EPS) meeting or exceeding TAS 110 and ASTM C578, Type IX, nominal 1.8 lb/ft2 density and minimum 25 psi compressive strength. FBC HVHZ approved Expanded polystyrene (EPS) with plastic facer meeting or exceeding TAS 110 and ASTM C578, Type IX, nominal 1.8 lb/ft2 density and minimum 25 psi compressive strength. High Traffic Applications: FBC HVHZ approved Extruded polystyrene (XPS) meeting or exceeding TAS 110 and ASTM C578, Type IV, minimum 1-inch thick and minimum 25 psi compressive strength. FBC HVHZ approved Expanded polystyrene (EPS) with plastic facer meeting or exceeding TAS 110 and ASTM C578, Type IX, minimum 1-inch thick and minimum 25 psi compressive strength. Recover Applications: FBC HVHZ approved XPS Fan-Fold Recover Board with plastic facer meeting or exceeding TAS 110 and ASTM C578, Type IV, 3/8-inch thick and minimum 25 psi compressive strength. FBC HVHZ approved EPS Recover Board meeting or exceeding TAS 110 and ASTM C578, Type IX, 1/2-inch thick and minimum 25 psi compressive strength. FBC HVHZ approved EPS Recover Board with plastic facer meeting or exceeding TAS 110 and ASTM C578, Type IX, 1/2-inch thick and minimum 25 psi compressive strength. TOPCOAT® FireOut™ Fire Barrier Coating, VersaShield® Fire-Resistant Roof Deck Protection or VersaShield® Solo™ Fire-Resistant Slip Sheet, installed in accordance with GAF published installation instructions and fire resistance certification listings, may be used as a non-load-bearing, fire-barrier / slip-sheet component within any system outlined herein. 4. If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5. Preliminary insulation attachment for System Type D-1 = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. Hot Asphalt (HA): Full mopping, 25-30 lbs/square. OlyBond 500 (OB500): Continuous ¾ to 1-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond 500 is referenced. GAF LRF Adhesive M (LRF-M): Continuous 1-inch wide ribbons, 12-inch o.c GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. Hot Asphalt (HA): MDP = -240.0 psf (Min. 0.5-inch thick) OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation) OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RN or RH) OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA) GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 2 of 34 9. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*. 10. For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners). 11. Fastener spacing for mechanical attachment is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing – prepared, signed and sealed by a qualified design professional – may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or RAS 137. 12. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with TAS 124. 13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For recover installations, the existing roof shall be examined in accordance with FBC 1521. For Recover Applications using System Type C-2 or any System Type D, the insulation is optional. Alternatively, a separator board may be installed prior to roof cover installation when using System Type C-2 or any System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The separator component shall be documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, or min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board. 2 2 Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd ) or EverGuard Polymat Cushioning Layer (6 oz/yd ). 15. For systems where specific lightweight insulating concrete (LWIC) is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. 16. For adhesive-applied membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows: Membrane Adhesive Method Rate EverGuard PVC-50, -60 or -80 EverGuard #2331 Bonding Adhesive (#2331) Contact (both sides) 1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane) EverGuard PVC Smooth or PVC XK EverGuard #2331 Bonding Adhesive (#2331) Contact (both sides) 1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane) EverGuard PVC XK Fleeceback Hot asphalt Wet lay (substrate) 25 lbs/square EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive (WB181) Wet lay (substrate) 0.83 to 1.0 gal/square EverGuard PVC XK Fleeceback GAF LRF Adhesive M (LRF-M) or LRF Adhesive O (LRF-O) Wet lay (substrate) 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. EverGuard PVC XK Fleeceback GAF 2-Part Roofing Adhesive (GAF 2-Part) Wet lay (substrate) “Spatter pattern” at 3.75 lbs/sq. 17. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and RAS 128 for determination of design wind pressures. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 3 of 34 TABLE 1A: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Roof Cover / Adhesive MDP (psf) LRF-M, OB500 or GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5 LRF-M, OB500 or GAF 2-Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -52.5 Attach Type Attach See Note 2 (#14 Fastener only) 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 (#14 Fastener only) 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: W-1. Min. 19/32-inch plywood or wood plank; 24” spans; 8d ring shank nails 6” o.c. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: W-2. Min. 19/32-inch plywood or wood plank; 24” spans; 8d ring shank nails 6” o.c. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH TABLE 1B: WOOD DECK - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. W-3. Deck (See Note 1) Min. 23/32-inch plywood or wood plan Base Insulation Layer One or more layers, min. 1.5-inch, any combination Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Top Insulation Layer Type Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board Fasteners See Note 2 Attach 1 per 2 ft2 Roof Cover / Adhesive EverGuard PVC-50, -60 or -80 / #2331 MDP (psf) -45.0* Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 4 of 34 TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER System No. Deck (See Note 1) Attachment Insulation Layer Fasteners W-4. Min. 19/32-inch plywood; 24inch span; 8d ring shank nails 6-inch o.c. at edges and intermediate supports One or more layers, any combination, (Tread Safe = min. 2-inch) Drill-Tec #14 Fastener and Drill-Tec RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe Plates W-5. Min. 19/32-inch plywood over nominal No. 2 wood trusses spaced max. 24-inch o.c.; 8d ring shank nails, 6” o.c. at edges and 12” o.c. at intermediate supports. (Optional) One or more layers, any combination, preliminarily attached (Tread Safe = min. 2-inch thick insulation) Drill-Tec #14 (min. 1-inch embedment) and Drill-Tec RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe Plates through to wood supports Roof Cover Density MDP (psf) 1 per 2.67 ft² (12 parts per 4 x 8 ft board) Fasteners are 6-, 24- and 42-inches from the board’s long edge and 12-, 36-, 60- and 84inches from the board’s short edge. EverGuard PVC XK or EveryGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -52.5 18-inch o.c. along wood supports, 24-inch o.c. EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -82.5 TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER System No. Deck (See Note 1) Insulation Type Roof Cover Attach Membrane Fasteners Attachment MDP (psf) W-6. Min. 19/32-inch plywood; 24-inch span; 8d ring shank nails 4-inch o.c. at edges and intermediate supports One or more layers, any combination, min. 0.5-inch Prelim. attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, DrillTec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 8-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld. -45.0 W-7. Min. 19/32-inch plywood; 24-inch span; 8d ring shank nails 4-inch o.c. at edges and intermediate supports One or more layers, any combination, min. 0.5-inch Prelim. attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, DrillTec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld. -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 5 of 34 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-1. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Additional layers of base insulation Hot asphalt EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-2. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2.0-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 4 ft2 Additional layers of base insulation Hot asphalt EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-3. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-4. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-5. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-6. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch thick SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-7. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-8. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-9. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-10. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-11. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.5-inch Dens Deck See Note 2 1 per 2 ft2 One or more layers, min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-12. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-13. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-14. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-15. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 6 of 34 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-16. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-17. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-18. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-19. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-20. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-21. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-22. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-23. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-24. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-25. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-26. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-27. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-28. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-29. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 7 of 34 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-30. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-31. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / WB181 -45.0* S-32. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / WB181 -45.0* EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: S-33. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-34. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-35. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-36. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-37. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-38. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-39. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-40. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-41. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-42. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-43. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 8 of 34 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-44. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-45. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-46. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-47. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-48. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-49. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-50. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: S-51. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-52. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-53. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-54. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-55. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-56. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-57. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 9 of 34 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-58. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-59. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-60. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-61. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-62. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 10 of 34 TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Thermal Barrier Type Fasten Temp Roof Insulation Layer(s) Attach Type Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-63. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-64. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN followed by Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-65. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN followed by Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-66. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* EVERGUARD PVC XK FLEECEBACK APPLICATIONS: S-67. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-68. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-69. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK GypsumFiber Roof Board See Note 2 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 11 of 34 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck‡ (See Note 1) Top Insulation Layer Base Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-70. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-71. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-72. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-73. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-74. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-75. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.5-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-76. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-77. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-78. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-79. Min. 22 ga., Type B, Grade 33 steel; 6’ spans, 5/8” puddle weld 6” o.c. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 1.78 ft2 EverGuard PVC Smooth or PVC XK / #2331 -60.0 S-80. Min. 22 ga., Type B, Grade 33 steel; 6’ spans, 5/8” puddle weld 6” o.c. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH See Note 2 1 per 1.78 ft2 EverGuard PVC Smooth or PVC XK / #2331 -67.5 EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-81. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* S-82. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* S-83. Min. 22 ga., Type B, Grade 33 steel or struct conc. One or more layers, any combination, min. 1.5inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: S-84. Min. 22 ga., Type B, Grade 33 steel or struct conc. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 (Optional) One or more layers, any combination Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 12 of 34 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck‡ (See Note 1) Base Insulation Layer Top Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) S-85. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-86. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation or ACFoam IV See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0 S-87. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* S-88. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-89. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-90. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-91. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -60.0 S-92. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-93. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. or struct conc. (Optional) One or more layers, any combination Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -67.5 EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: S-94. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-95. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-96. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0 S-97. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-98. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. or struct conc. (Optional) One or more layers, any combination Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -67.5 ‡ NOTE: As-tested steel deck performance under TAS 114, Appendix J indicates steel deck at max. 6’ spans attached with 5/8” diameter puddle welds spaced 6” o.c. may be substituted for Tek/5 screws or Traxx/5 screws in the Table 2B-1A assemblies up to a maximum design pressure of -82.5 psf. See Note 1. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 13 of 34 TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer No. (See Note 1) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: Min. 0.625-inch Dens Deck or min. 0.5-inch SECUROCK Glass-Mat Roof Board, loose-laid, Min. 22 ga., Type followed by UnderRoof 2 Polyester-Surfaced Leak Barrier, UnderRoof HT High S-99. B, Grade 33 steel Temperature Leak Barrier or WeatherWatch XT Mat Surfaced Leak Barrier, self-adhered, or struct conc. followed by min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, loose-laid Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-100. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-101. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-102. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-103. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-104. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Min. 22 ga., Type loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 S-105. B, Grade 33 steel Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc. adhered S-106. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Top Insulation Layer Type Roof Cover / Adhesive MDP (psf) 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 3.2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* Fasten Attach Min. 0.625-inch Dens Deck Prime See Note 2 Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH Min. 2-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.25-inch Dens Deck Prime Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.5-inch Dens Deck Prime Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.625-inch Dens Deck Prime Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-107. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 14 of 34 TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER Deck‡ (See Note 1) Insulation Layer S-108. S-109. System No. Attachment Fasteners Density Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5inch; (Tread Safe = min. 2inch) Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates 1 per 5.3 ft² (6 parts per 4 x 8 ft board) Fasteners located in each of the four corners of the board and at mid-span of the 96-inch length. Fasteners are 6-inches from the board’s long edges and 12-inches and 48-inches from the board’s short edges. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Drill-Tec SXHD and Drill-Tec RhinoBond PVC XHD Plates 24 x 36 inch grid Roof Cover MDP (psf) EverGuard PVC-50, -60 or -90 bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -45.0* EverGuard PVC XK bonded or EverGuard PVC Smooth to Drill-Tec RhinoBond PVC XHD Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -45.0 1 per 4 ft² (8 parts per 4 x 8 ft board) S-110. Min. 20 ga., type B, Grade 33 steel; 7’ span, 5/8” puddle weld 6” o.c. One or more layers, any combination, min. 1-inch; (Tread Safe = min. 2-inch) Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. S-111. Min. 22 ga., Type B, Grade 33 steel; 6’ span, Traxx/5 or Tek/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Drill-Tec SXHD and Drill-Tec RhinoBond PVC XHD Plates EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -60.0 S-112. Min. 22 ga., type B, Grade 33 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, (Tread Safe = min. 2-inch) Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -67.5 24 x 24 inch grid 1 per 2.67 ft² (12 parts per 4 x 8 ft board) Fasteners are 6-, 24- and 42-inches from the board’s long edge and 12-, 36-, 60- and 84-inches from the board’s short edge. -52.5 ‡ NOTE: As-tested steel deck performance under TAS 114, Appendix J indicates steel deck at max. 6’ spans attached with 5/8” diameter puddle welds spaced 6” o.c. may be substituted for Tek/5 screws or Traxx/5 screws in the Table C-2 assemblies up to a maximum design pressure of -67.5 psf. See Note 1. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 15 of 34 TABLE 2C: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER System No. Deck (See Note 1) Insulation Type Roof Cover Attach Membrane Fasteners Attachment MDP (psf) EVERGUARD PVC-50, -60 OR -80: S-113. Min. 22 ga., type B, Grade 80 steel; 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. Attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates 12-inch o.c. within 5.5-inch wide laps spaced 75.5-inch o.c. and sealed with a 1.5-inch heat weld. -45.0 S-114. Min. 22 ga., type B, Grade 33 steel; 7’ spans, 5/8” puddle weld 12” o.c. One or more layers, any combination, min. 1.5-inch Prelim. Attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2inch Barbed Plates 6-inch o.c. within 6-inch wide laps spaced 75inch o.c. and sealed with a 1.5-inch heat weld. -52.5 S-115. Min. 22 ga., type B, Grade 80 steel; 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. Attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates 6-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld. -75.0 EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK: S-116. Min. 22 ga., type B, Grade 33 steel; 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. Attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec #14 Fasteners with Drill-Tec 2 in. Barbed Plates 6-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 2-inch heat weld. -45.0 S-117. Min. 22 ga., type B, Grade 80 steel’ 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates 6-inch o.c. within minimum 5.5-inch wide laps spaced maximum 75.5-inch o.c. and sealed with a 2-inch heat weld -45.0 S-118. Min. 22 ga., type B, Grade 80 steel’ 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec SXHD #21 with DrillTec 2 ¾ in. Barbed SXHD Plates 12-inch o.c. within minimum 6-inch wide laps spaced maximum 75-inch o.c. and sealed with a 2-inch heat weld -45.0 S-119. Min. 22 ga., type B, Grade 33 steel; 6’ spans, Traxx/5 screw 6” o.c. One or more layers, any combination, min. 1.5-inch Prelim. Attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates 6-inch o.c. within 6-inch wide laps spaced 114inch o.c. and sealed with a 1.5-inch heat weld. -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 16 of 34 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Vapor Barrier Base Insulation Layer Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC-50, -60 or -80 APPLICATIONS: C-1. Struct conc. (Optional) See Note A below Min. 1-inch EnergyGuard RA OB500 None N/A EverGuard PVC-50, -60 or -80 / #2331 -325.0* C-2. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III OB500 Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -240.0* C-3. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2Part Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board GAF 2Part EverGuard PVC-50, -60 or -80 / #2331 -240.0* EVERGUARD PVC SMOOTH OR PVC XK / EVERGUARD #2331 BONDING ADHESIVE: C-4. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -232.5* C-5. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 (Optional) Additional layer of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -247.5* C-6. Struct conc. D41 or Matrix #307 & UnderRoof 2 PolyesterSurfaced Leak Barrier Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5* C-7. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5* C-8. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -232.5* C-9. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -247.5* C-10. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -202.5* C-11. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -202.5* C-12. Struct conc. None Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layer of base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -162.5* C-13. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -232.5* C-14. Struct conc. None Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -97.5* C-15. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC Smooth or PVC XK / #2331 -232.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 17 of 34 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. (See Note 1) C-16. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -202.5* C-17. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -232.5* C-18. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -232.5* C-19. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -202.5* Min. 1-inch EnergyGuard RH HA (Optional) Additional layers of base insulation HA EverGuard PVC XK Fleeceback / Hot asphalt -490.0* Deck Vapor Barrier Type Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC XK FLEECEBACK IN HOT ASPHALT: C-20. Struct conc. (primed) None EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: C-21. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -90.0* C-22. Struct conc. D41 or Matrix #307 & UnderRoof 2 PolyesterSurfaced Leak Barrier Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5* C-23. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5* C-24. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -90.0* C-25. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0* C-26. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0* C-27. Struct conc. None Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -97.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 18 of 34 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. (See Note 1) C-28. Struct conc. C-29. Struct conc. Deck Base Insulation Layer Vapor Barrier Top Insulation Layer Roof Cover / Adhesive MDP (psf) GAF 2Part EverGuard PVC XK Fleeceback / WB181 -90.0* Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / WB181 -90.0* Type Attach Type (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN GAF 2Part (Optional) Additional layers of base insulation (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN GAF 2Part Attach EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: C-30. Struct conc. (Optional) See Note A below Min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c. -45.0* C-31. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* C-32. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* C-33. Struct conc. (Optional) See Note A below (Optional) Min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. -45.0* C-34. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* C-35. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-36. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-37. Struct conc. (Optional) See Note A below Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -195.0* C-38. Struct conc. None Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. -45.0* C-39. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* C-40. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 19 of 34 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. (See Note 1) Roof Cover / Adhesive MDP (psf) C-41. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* C-42. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-43. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN LRF-M (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-44. Struct conc. None Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -195.0* C-45. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* C-46. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime GAF 2Part EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* C-47. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* C-48. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-49. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN GAF 2Part (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* C-50. Struct conc. (Optional) See Note A below Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -195.0* OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0* Deck Vapor Barrier Type Attach Type Attach EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: C-51. Struct conc. (Optional) See Note A below Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 0.5-inch EnergyGuard Polyiso Insulation Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 20 of 34 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. (See Note 1) Roof Cover / Adhesive MDP (psf) C-52. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* C-53. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* C-54. Struct conc. (Optional) See Note A below Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None N/A EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -195.0* C-55. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0* C-56. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied C-57. Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN LRF-M (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* C-58. Struct conc. None Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M None N/A EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -195.0* C-59. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0* C-60. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* C-61. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN GAF 2Part (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* C-62. Struct conc. (Optional) See Note A below Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part None N/A EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -195.0* Deck Vapor Barrier Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Attach Type Attach Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 21 of 34 A. The following are options for installation of an optional vapor barrier / temporary roof on the concrete deck prior to insulation placement. If vapor barrier / temp roof is installed, concrete deck shall be primed with Matrix 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation adhesive noted below. 1. 2. 3. For use with OB500 applied insulation: One or two plies, asphalt-applied GAF base and/or ply sheet: Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage: Ruberoid Torch Smooth, heat welded: Ruberoid HW 25 Smooth, heat welded: Ruberoid HW Smooth, heat welded: UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered: MDP -352.5 psf MDP -202.5 psf MDP -165.0 psf MDP -180.0 psf MDP -232.5 psf MDP -127.5 psf For use with GAF 2-Part applied insulation: One or two plies, asphalt-applied GAF base ply and/or ply: Optional asphalt-applied GAF base ply, ply or base membrane with asphalt-applied GAF SBS cap membrane: Optional asphalt-applied GAF base ply, ply or base membrane or heat-welded GAF base membrane with heat-welded GAF SBS or APP cap membrane: Optional self-adhering Liberty base membrane with Liberty cap membrane: Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded: For use with GAF LRF-Adhesive M: Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded: MDP -262.5 psf MDP -270.0 psf MDP -169.0 psf MDP -250.0 psf MDP -180.0 psf MDP -180.0 psf TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Roof Deck Roof Cover / Adhesive MDP (psf) C-63. Struct conc. EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c. -45.0* C-64. Struct conc. primed with Matrix #307 EverGuard PVC XK Fleeceback / Hot asphalt at 25 lbs/square -502.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 22 of 34 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck (See Note 1) System No. Roof Deck Base Insulation Layer LWIC (See Note 15) Type Coverboard Attach Type Attach Roof Cover / Adhesive MDP (psf) LWC-1. Struct. conc. Min. 200 psi, min. 2inch thick Elastizell Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -225.0* LWC-2. Struct. conc. Min. 200 psi, min. 2inch thick Elastizell Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -180.0* LWC-3. Struct. conc. Min. 200 psi, min. 2inch thick Celcore Cellular Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -222.5* LWC-4. Struct. conc. Min. 200 psi, min. 2inch thick Mearlcrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -240.0* TABLE 4B: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Roof Deck (See Note 1) Structural Deck LWIC (See Note 15) Base Sheet Roof Cover Type Fasteners Attach Base GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in), Drill-Tec Base Sheet Fastener E (1.7 in), Drill-Tec Locking Impact Nail or Trufast FM-290 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 or Ruberoid Mop Plus Smooth in hot asphalt or one or two plies Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch-applied GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in), Drill-Tec Base Sheet Fastener E (1.7 in), Drill-Tec Locking Impact Nail or Trufast FM-290 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in two, equally spaced, staggered center rows One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 or Ruberoid Mop Plus Smooth in hot asphalt or one or two plies Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch-applied Cap MDP (psf) HYBRID SYSTEMS: LWC-5. LWC-6. Min. 22 ga., type BV, 40 ksi; 6 ft spans; 5/8” puddle welds or Traxx/5 screws 6” o.c. Min. 340 psi, min. 2-inch thick cellular lightweight concrete. Note: To qualify Min. 22 ga., type BV, 40 ksi; 6 ft spans; 5/8” puddle welds or Traxx/5 screws 6” o.c. Min. 340 psi, min. 2-inch thick cellular lightweight concrete. Note: To qualify the LWC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per TAS105 or ANSI/SPRI FX-1 the LWC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per TAS105 or ANSI/SPRI FX-1 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 EverGuard PVC XK Fleeceback in -52.5 hot apshalt EverGuard PVC XK Fleeceback in GAF 2-Part, spatterapplied -52.5 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 23 of 34 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Roof Deck System No. Roof Cover Min. Compressive Strength (psi) Min. Thick (in.) Membrane Adhesive MDP (psf) 300 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5* 180 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5* 180 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -102.5* LWIC (See Note 15) Structural Deck Type LWC-7. Min. 22 ga., type BV, Grade 33 steel; 6’ spans, 5/8” puddle welds 6” o.c. LWC-8. Min. 22 ga., type BV, Grade 33 steel; 6’ spans, 5/8-inch puddle welds, 6” o.c. LWC-9. Structural concrete LWC-10. Structural concrete Elastizell 220 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -200.0* LWC-11. Structural concrete Mearlcrete 290 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -205.0* LWC-12. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -225.0* LWC-13. Structural concrete Elastizell 300 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 6-inch o.c. -45.0* LWC-14. Structural concrete Mearlcrete 730 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 6-inch o.c. -45.0* 180 2 EverGuard PVC XK Fleeceback LRF-M, ribbons 6-inch o.c. -92.5* 180 2 EverGuard PVC XK Fleeceback LRF-O, ribbons 6-inch o.c. -112.5* Mearlcrete Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. LWC-15. Structural concrete LWC-16. Structural concrete LWC-17. Min. 22 ga., type BV, Grade 33 steel; 6’ spans, 5/8” puddle welds 6” o.c. Mearlcrete 300 2 EverGuard PVC XK Fleeceback LRF-M, 4-inch o.c. -52.5* LWC-18. Structural concrete Elastizell 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -210.0* LWC-19. Structural concrete Mearlcrete or Insulcel 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -270.0* LWC-20. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback LRF-M, 4-inch o.c. -225.0* LWC-21. Structural concrete Celcore Cellular Concrete 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -300.0* Cellular lightweight insulating concrete; Note: To qualify LWC-22. Min. 22 ga., type BV, Grade 33 steel; 6’ spans, 5/8-inch puddle welds, 6” o.c. 180 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5* Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 24 of 34 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Roof Deck System No. Roof Cover LWIC (See Note 15) Structural Deck Type Min. Compressive Strength (psi) Min. Thick (in.) Membrane Adhesive MDP (psf) LWC-23. Min. 22 ga., type BV, Grade 33 steel; 6’ spans, 5/8” puddle welds 6” o.c. Mearlcrete 300 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5* LWC-24. Min. 22 ga., 33 ksi, type BV (0.5%) steel; 6’ spans, 5/8” puddle welds 6” o.c. Elastizell 200 3 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -60.0* 180 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -102.5 Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve MCRF of 97 lbf or greater when tested per TAS105. LWC-25. Structural concrete LWC-26. Structural concrete Elastizell 220 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -200.0* LWC-27. Structural concrete Mearlcrete 290 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -205.0* LWC-28. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -225.0* LWC-29. Structural concrete Insulcel 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -270.0* LWC-30. Structural concrete Celcore Cellular Concrete 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -300.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 25 of 34 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) CWF-1. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, ACFoam III OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* CWF-2. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, ACFoam III OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* CWF-3. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c. -45.0* CWF-4. Min. 2-inch Tectum Plank or Tectum LS Plank (Optional) Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c. -45.0* CWF-5. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / LRFM, 12-inch o.c. -45.0* CWF-6. Min. 2-inch Tectum Plank or Tectum LS Plank or Fibroplank Min. 1.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard RA or ACFoam III GAF 2-Part (Optional) Additional layer of Base Insulation GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5* CWF-7. Min. 2-inch Tectum Plank or Tectum LS Plank or Fibroplank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 26 of 34 TABLE 6A: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Deck (See Notes 1 & 12) G-1. Existing poured gypsum or gypsum plank Min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation G-2. Existing poured gypsum or gypsum plank Min. 1-inch EnergyGuard RA OB500 G-3. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III G-4. Existing poured gypsum or gypsum plank G-5. Existing poured gypsum or gypsum plank Roof Cover / Adhesive MDP (psf) OB500 EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. -45.0* None N/A EverGuard PVC-50, -60 or -80 / #2331 -262.5* OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -112.5* Min. 1-inch EnergyGuard RH LRF-M None N/A EverGuard PVC Smooth / #2331 -352.5* Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -240.0* Type Attach Type Attach TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Notes 1 & 11) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR PVC XK APPLICATIONS: G-6. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-7. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-8. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-9. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-10. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 288 lbf) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 27 of 34 TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Notes 1 & 11) Base Insulation Layer Top Insulation Layer Type Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) G-11. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-12. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-13. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-14. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-15. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 288 lbf) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* EVERGUARD PVC XK FLEECEBACK APPLICATIONS: G-16. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-17. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-18. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-19. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-20. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 288 lbf) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 28 of 34 TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Notes 1 & 11) Base Insulation Layer Top Insulation Layer Type Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) G-21. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-22. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-23. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-24. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation or EnergyGuard RH Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-25. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 288 lbf) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 29 of 34 TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Deck (See Notes 1 & 11) System No. Base Insulation Layer Top Insulation Layer Type Fasteners Attach Roof Cover / Adhesive MDP (psf) G-26. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-27. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-28. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 180 lbf) 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 or LRF-M or LRF-O, 12-inch o.c. -45.0* G-29. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) (MCRF > 261 lbf) 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / WB181 or LRF-M or LRF-O, 12-inch o.c. -45.0* TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (See Notes 1 & 12) Roof Cover / Adhesive MDP (psf) G-30. Existing poured gypsum or gypsum plank EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c. -45.0* G-31. Existing poured gypsum or gypsum plank EverGuard PVC XK Fleeceback / LRF-O, 6-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 30 of 34 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (See Notes 1 & 12) Base Insulation Layer Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC APPLICATIONS: R-1. Existing asphaltic BUR or mineral surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -120.0* R-2. Existing asphaltic BUR or mineral surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC-50, -60 or -80 / #2331 -240.0* EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: R-3. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard PVC Smooth or PVC XK / #2331 -45.0* R-4. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard PVC Smooth or PVC XK / #2331 -225.0* R-5. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over struct conc. deck (Optional) Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5* R-6. Existing asphaltic BUR or mineral surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -120.0* R-7. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -225.0* R-8. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -202.5* R-9. Existing asphaltic BUR or mineral surface cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -120.0* R-10. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -45.0* R-11. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -75.0* R-12. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -225.0* R-13. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0* R-14. Existing smooth surfaced BUR or granule surface roof cover (Optional) Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 31 of 34 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Substrate (See Notes 1 & 12) R-15. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Min. 0.25-inch Dens Deck Prime R-16. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M R-17. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation Type Roof Cover / Adhesive MDP (psf) LRF-M EverGuard PVC Smooth or PVC XK / #2331 -225.0* Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0* LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -202.5* Attach Type Attach EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN WB181 BONDING ADHESIVE: R-18. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard PVC XK Fleeceback / WB181 -90.0* R-19. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / WB181 -90.0* R-20. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -90.0* R-21. Existing smooth surfaced BUR / APP modified bitumen or granule surface roof cover over struct conc. deck (Optional) Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5* R-22. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC XK Fleeceback / WB181 -75.0* R-23. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC XK Fleeceback / WB181 -90.0* R-24. Existing smooth surfaced BUR or granule surface roof cover (Optional) Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0* R-25. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0* R-26. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0* R-27. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 32 of 34 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (See Notes 1 & 12) R-28. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Base Insulation Layer Type Min. 0.5-inch EnergyGuard Polyiso Insulation Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0* EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN LRF ADHESIVE M OR LRF ADHESIVE O: R-29. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation OB500 None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* R-30. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation or ACFoam IV OB500 None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* R-31. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* R-32. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* R-33. Existing smooth- or granule-surfaced BUR; smooth- or granule-surfaced SBS modified bitumen or granule-surfaced APP modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* R-34. Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced SBS modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation LRF-M None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* R-35. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation or ACFoam IV LRF-M None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* R-36. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* R-37. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 33 of 34 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Substrate (See Notes 1 & 12) R-38. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board R-39. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN GAF 2Part Type Roof Cover / Adhesive MDP (psf) LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0* Attach Type Attach EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN GAF 2-PART ROOFING ADHESIVE: R-40. Existing smooth- or granule-surfaced BUR; smooth- or granule-surfaced SBS modified bitumen or granule-surfaced APP modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* R-41. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* R-42. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0* TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Substrate (See Notes 1 & 12) Roof Cover / Adhesive MDP (psf) R-43. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* R-44. Existing asphaltic granule surfaced roof cover over steel deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0* R-45. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen over steel deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -60.0* R-46. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen over structural concrete deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -337.5* R-47. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0 R-48. Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over steel deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0* R-49. Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over structural concrete deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -337.5* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.12.13-4-R9 for FL16739-R8 Revision 9: 12/15/2015 Appendix 1, Page 34 of 34