Page 1 of 2 Florida Building Code Online

advertisement
Florida Building Code Online
BCIS Home
Log In
User Registration
Page 1 of 2
Hot Topics
Submit Surcharge
Stats & Facts
Publications
FBC Staff
BCIS Site Map
Links
Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL16739-R8
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
GAF
Address/Phone/Email
1 Campus Drive
Parisppany, NJ 07054
(973) 872-4421
lindareith@trinityerd.com
Authorized Signature
Beth McSorley
lindareith@trinityerd.com
Technical Representative
Beth McSorley (current)
Address/Phone/Email
1 Campus Drive
Parsippany, NJ 07054
(973) 872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Single Ply Roof Systems
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who
developed the Evaluation Report
Robert Nieminen
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
08/16/2016
Validated By
John W. Knezevich, PE

Validation Checklist - Hardcopy Received
Certificate of Independence
FL16739_R8_COI_2015_01_COI_Nieminen.pdf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D4434
2009
TAS 110
2000
TAS 114
2011
Equivalence of Product Standards
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6... 2/12/2016
Florida Building Code Online
Page 2 of 2
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted
12/16/2015
Date Validated
12/16/2015
Date Pending FBC Approval
12/19/2015
Date Approved
02/10/2016
Summary of Products
FL #
Model, Number or Name
Description
16739.1
EverGuard PVC Single Ply
Roof Systems
Thermoplastic single ply roof systems
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: +N/A/-502.5
Other: 1.) The design pressure herein
pertains to one system. Refer to ER Appendix
for all systems and maximum design
pressures. 2.) Refer to ER Section 5 for Limits
of Use.
Installation Instructions
FL16739_R8_II_2015_12_FINAL_A1_ER_GAF_PVC_HVHZ_FL16739R8.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL16739_R8_AE_2015_12_FINAL_ER_GAF_PVC_HVHZ_FL16739R8.pdf
Created by Independent Third Party: Yes
Back
Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not
send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.
*Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department
with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public
record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6... 2/12/2016
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street, Unit 13
Oxford, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
Evaluation Report 01506.12.14-4-R9
FL16739-R8
Date of Issuance: 12/19/2013
Revision 9: 12/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 5th Edition (2014) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted
herein.
DESCRIPTION: EverGuard® PVC Single-Ply Roof Membrane Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “Engineer Evaluated, FBC (HVHZ)” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 34-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facimilie seal appearing was authorized by Robert Nieminen, P.E.
on 12/15/2015. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in
any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1.
SCOPE:
Product Category:
Roofing
Sub-Category:
Single Ply Roof Systems
®
Compliance Statement: EverGuard PVC Single-Ply Roof Membrane Systems, as produced by GAF, have
demonstrated compliance with the following sections of the Florida Building Code, HVHZ through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2.
3.
STANDARDS:
Section
Property
Standard
Year
1523.6.2
TAS 110
TAS 110
Testing Requirements
System Performance
Physical Properties
TAS 110
TAS 114
ASTM D4434
2000
2011
2009
Entity
Examination
Reference
Date
ATI (TST1558)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
FET (TST7393)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
Physical Properties
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
FM 4470 / 4474
FM 4470 / 4474
TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
52825.01-106-31
06-047
07-001
07-002
07-007
07-029
07-031
08-031
11-057
11-058
11-059
11-060
11-061
11-062
11-063
11-066
12-005
12-006
12-007
12-009
12-010
12-011
12-021
12-022
12-017
12-020
12-027
12-028
12-032
11-015-R1
11-018-R1
11-022-R1
F35940.10.11-2-R2
F35940.12.11-R2
F42130.06.13
F42130.06.13-1
F42130.09.13
GAF-SC8580.14
GAF-SC8580.14
08-050182
3003956
3003955
3014692
3024709
06/15/2005
12/21/2006
01/12/2007
01/12/2007
01/19/2007
03/08/2007
05/09/2007
05/05/2008
09/30/2011
10/03/2011
10/04/2011
10/05/2011
10/06/2011
10/07/2011
10/08/2011
11/21/2011
04/09/2012
04/09/2012
04/10/2012
04/20/2012
04/20/2012
04/20/2012
04/26/2012
04/26/2012
05/07/2012
05/08/2012
05/22/2012
05/22/2012
08/23/2012
08/29/2012
08/29/2012
08/29/2012
02/27/2012
02/27/2012
06/05/2013
06/05/2013
09/13/2013
03/25/2015
07/20/2015
06/26/2008
02/18/2000
03/05/2002
08/05/2003
10/21/2005
REFERENCES:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.12.13-4-R9
FL16739-R8
Revision 9: 12/15/2015
Page 2 of 5
Entity
Examination
Reference
Date
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
IRT (TST5296)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
TAS 114
ASTM D4434
ASTM D4434
ASTM D4434
Physical Properties
Component Performance
Component Performance
Component Performance
Component Performance
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
FM 4470 / TAS 114
Quality Control
Quality Control
Quality Control
Quality Control
3023368
3028606
3026964
3031127
3033126
3034394
3037879
797-07043-267
3044862
3044914
3045789
3046328
3041769
3046403
797-07886-267
797-07849-267
3046054
3047606
3048122
797-08217-267
3047237
3047636
797-09495-267
797-09594-267
797-09892-267
04-006
NX21J0A
NX21J0B
NX21J0C
GAF-373-02-01
GAF-462-02-01
GAF-462-02-02
GAF-462-02-03
GAF-462-02-04
GAF-457-02-02
GAF-457-02-04
GAF-457-02-06
GAF-457-02-07
GAF-457-02-08
GAF-510-02-02
GAF-515-02-01
GAF-515-02-03
GAF-516-02-03
GAF-525-02-02
GAF-525-02-03
GAF-462-02-07
GAF-462-02-08
GAF-462-02-09
GAF-462-02-10
GAF-462-02-11
GAF-538-02-03
ML File No. R1306, R9228
ML File No. R1306, R21864
Inspection Report, PA
Inspection Report, NJ
03/20/2006
02/23/2007
07/25/2007
10/01/2007
07/11/2008
02/27/2009
02/04/2010
01/16/2012
05/11/2012
06/18/2012
07/12/2012
09/13/2012
09/27/2012
09/28/2012
11/21/2012
12/03/2012
12/21/2012
02/26/2013
04/29/2013
05/01/2013
07/15/2013
08/08/2013
05/27/2014
06/24/2014
08/12/2014
02/16/2004
06/01/2011
07/20/2011
06/01/2011
10/15/2012
11/15/2013
11/18/2013
11/18/2013
11/18/2013
01/20/2014
01/24/2014
01/24/2014
01/24/2014
01/24/2014
04/08/2014
05/13/2014
05/13/2014
05/13/2014
06/23/2014
06/23/2014
07/01/2014
07/01/2014
07/01/2014
07/01/2014
07/01/2014
08/13/2014
01/27/2015
03/11/2015
08/07/2015
11/12/2015
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.12.13-4-R9
FL16739-R8
Revision 9: 12/15/2015
Page 3 of 5
4.
PRODUCT DESCRIPTION:
This Evaluation Report covers EverGuard® PVC Single-Ply Roof Membrane Systems installed in accordance with GAF
published installation instructions and the Limitations / Conditions of Use herein.
®
®
®
 EverGuard PVC-50, EverGuard PVC-60 and EverGuard PVC-80 membranes are nominal 50-mil (1.3 mm), 60-mil
(1.5-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (PVC) roof covers, available in 81 and 40.5inch wide rolls.
®
 EverGuard PVC Smooth membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick,
polyester scrim reinforced, thermoplastic (PVC) single-ply roof membranes, available in 120 and 60-inch wide rolls.
®
 EverGuard PVC XK membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic
®
fiber reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membranes, available in 120 and 60-inch wide rolls.
®
 EverGuard PVC XK Fleeceback membranes are nominal 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic fiber
®
reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membrane with a nonwoven polyester felt backing,
available in 120 and 76-inch wide rolls.
5.
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 Fire classification is not part of this Evaluation Report; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.4 The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’
conditions under TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the
satisfaction of the AHJ.
5.5 Fastener spacing for mechanical attachment of insulation, anchor/base sheet or membrane is based on a
minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official, a
revised fastener spacing – prepared, signed and sealed by a qualified design professional – may be submitted.
Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or RAS 137.
5.5.1 If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field
withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening
patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard
TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and
sealed by a qualified design professional.
5.6 For systems where specific lightweight insulating concrete is referenced, consult the current HVHZ product
approval documentation for specific deck construction and limitations. For systems where specific lightweight
insulating concrete is not referenced, the minimum design mix shall be for minimum 300 psi cellular material.
5.7 For recover installations, the existing roof shall be examined in accordance with FBC 1521.
5.8 Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117
and/or RAS 137 by a qualified design professional. This extrapolation is not permitted for systems marked with
an asterisk*.
5.9 All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.12.13-4-R9
FL16739-R8
Revision 9: 12/15/2015
Page 4 of 5
5.10 For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be
applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor
extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and
extended corners).
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system
shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with TAS 124.
5.12 All products listed herein shall have quality assurance audit in accordance with the Florida Building Code and
Florida Administrative Code Rule 61G20-3.
6.
INSTALLATION:
®
6.1 EverGuard PVC Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per TAS 114 has already been applied). Refer
to FBC 1620 and RAS 128 for determination of design wind loads.
6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed
running perpendicular to steel deck flutes.
7.
QUALITY ASSURANCE ENTITY:
UL, LLC. – QUA9625; (314) 578-3406; k.chancellor@ul.com
- THE 34-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.12.13-4-R9
FL16739-R8
Revision 9: 12/15/2015
Page 5 of 5
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
1A
Wood
New, Reroof (Tear-Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
Page
4
1B
Wood
New, Reroof (Tear-Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
4
1C
Wood
New, Reroof (Tear-Off) or Recover
C-2
Plate-Bonded Roof Cover
5
1D
Wood
New, Reroof (Tear-Off) or Recover
D-1
Mechanically Attached Roof Cover
2A-1
Steel or Conc.
New, Reroof (Tear-Off) or Recover
B-1
Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
2A-2
Steel or Conc.
New, Reroof (Tear-Off) or Recover
B-2
Mechanically Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover
2B-1A
Steel or Conc.
New, Reroof (Tear-Off) or Recover
C-1
Mechanically Attached Insulation, Bonded Roof Cover
2B-1B
Steel or Conc.
New, Reroof (Tear-Off) or Recover
C-1A
Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover
14
2B-2
Steel or Conc.
New, Reroof (Tear-Off) or Recover
C-2
Mechanically Attached Insulation, Plate-Bonded Roof Cover
15
2C
Steel
New, Reroof (Tear-Off) or Recover
D-1
Mechanically Attached Roof Cover
3A
Concrete
New or Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
3B
Concrete
New or Reroof (Tear-Off)
F
Non-Insulated, Bonded Roof Cover
22
4A
LWIC
New or Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
4B
LWIC
New or Reroof (Tear Off)
E
Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
4C
LWIC
New or Reroof (Tear-Off)
F
Non-Insulated, Bonded Roof Cover
5A
CWF
New or Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
6A
Gypsum
Reroof (Tear-Off)
A-1
Bonded Insulation, Bonded Roof Cover
6B
Gypsum
Reroof (Tear-Off)
B-1
Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
6C
Gypsum
Reroof (Tear-Off)
C-1
Mechanically Attached Insulation, Bonded Roof Cover
6D
Gypsum
Reroof (Tear-Off)
F
Non-Insulated, Bonded Roof Cover
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
7B
Concrete
Recover
F
Non-Insulated, Bonded Roof Cover
5
6-10
11
12-13
16
17-22
23
24-25
26
27
27-29
30
30
31-34
34
The following notes apply to the systems outlined herein:
1.
The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to ‘as-tested’ conditions under TAS 114, Appendix J. Roof decks shall be in accordance with
FBC (HVHZ) requirements to the satisfaction of the AHJ.
2.
Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
 Wood Deck:
Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec
AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. ¾-inch plywood penetration or minimum 1-inch wood plank
embedment.
 Steel Deck:
Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom
Plate or Drill-Tec AccuTrac Recessed Plate (insulation only). Minimum ¾-inch steel penetration, engage the top flute of the steel deck.
 Concrete Deck:
Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac
Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP 3S. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener
manufacturer’s published installation instructions.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 1 of 34
3.
Unless otherwise noted, insulation may be any one layer or combination of FBC (HVHZ) Approved polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral
wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover.
A separator is required when using polystyrene insulation with smooth-backed EverGuard® PVC membranes (EverGuard® PVC XK, EverGuard® PVC Smooth and EverGuard® PVC-50; 60; 80).
Refer to GAF published installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuard® roofing systems:
Insulation:
 FBC HVHZ approved Expaned polystyrene (EPS) meeting or
exceeding TAS 110 and ASTM C578, Type IX, nominal 1.8 lb/ft2
density and minimum 25 psi compressive strength.
 FBC HVHZ approved Expanded polystyrene (EPS) with plastic
facer meeting or exceeding TAS 110 and ASTM C578, Type IX,
nominal 1.8 lb/ft2 density and minimum 25 psi compressive
strength.
High Traffic Applications:
 FBC HVHZ approved Extruded polystyrene (XPS) meeting or
exceeding TAS 110 and ASTM C578, Type IV, minimum 1-inch
thick and minimum 25 psi compressive strength.
 FBC HVHZ approved Expanded polystyrene (EPS) with plastic
facer meeting or exceeding TAS 110 and ASTM C578, Type IX,
minimum 1-inch thick and minimum 25 psi compressive strength.
Recover Applications:
 FBC HVHZ approved XPS Fan-Fold Recover Board with plastic
facer meeting or exceeding TAS 110 and ASTM C578, Type IV,
3/8-inch thick and minimum 25 psi compressive strength.
 FBC HVHZ approved EPS Recover Board meeting or exceeding
TAS 110 and ASTM C578, Type IX, 1/2-inch thick and minimum 25
psi compressive strength.
 FBC HVHZ approved EPS Recover Board with plastic facer
meeting or exceeding TAS 110 and ASTM C578, Type IX, 1/2-inch
thick and minimum 25 psi compressive strength.
TOPCOAT® FireOut™ Fire Barrier Coating, VersaShield® Fire-Resistant Roof Deck Protection or VersaShield® Solo™ Fire-Resistant Slip Sheet, installed in accordance with GAF published
installation instructions and fire resistance certification listings, may be used as a non-load-bearing, fire-barrier / slip-sheet component within any system outlined herein.
4.
If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine
enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or
RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional.
5.
Preliminary insulation attachment for System Type D-1 = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board.
6.
Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s
published instructions.
 Hot Asphalt (HA):
Full mopping, 25-30 lbs/square.
 OlyBond 500 (OB500):
Continuous ¾ to 1-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used
where OlyBond 500 is referenced.
 GAF LRF Adhesive M (LRF-M):
Continuous 1-inch wide ribbons, 12-inch o.c
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c.
 Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
 Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7.
Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with
the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that
listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table.
 Hot Asphalt (HA):
MDP = -240.0 psf (Min. 0.5-inch thick)
 OlyBond 500 (OB500):
MDP = -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation)
 OlyBond 500 (OB500):
MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RN or RH)
 OlyBond 500 (OB500):
MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA)
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
MDP = -117.5 psf (Min. 1.0-inch thick)
8.
Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 2 of 34
9.
Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing
Application Standard RAS 117 and/or RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*.
10. For assemblies marked with an asterisk*, the maximum design pressure (MDP) limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither
rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners).
11. Fastener spacing for mechanical attachment is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing – prepared, signed and sealed by a qualified design professional – may be
submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117 or RAS 137.
12. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the
satisfaction of the AHJ, as documented through field uplift testing in accordance with TAS 124.
13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes.
14. For recover installations, the existing roof shall be examined in accordance with FBC 1521. For Recover Applications using System Type C-2 or any System Type D, the insulation is optional.
Alternatively, a separator board may be installed prior to roof cover installation when using System Type C-2 or any System Type D or a separator sheet may be installed prior to roof cover
installation when using any System Type D. The separator component shall be documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover in Recover applications.
 Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN,
EnergyGuard Ultra, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, or min. 0.25-inch Dens Deck, Dens Deck Prime,
SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board.
2
2
 Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd ) or EverGuard Polymat Cushioning Layer (6 oz/yd ).
15. For systems where specific lightweight insulating concrete (LWIC) is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,
for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi.
16. For adhesive-applied membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as
follows:
Membrane
Adhesive
Method
Rate
EverGuard PVC-50, -60 or -80
EverGuard #2331 Bonding Adhesive (#2331)
Contact (both sides)
1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane)
EverGuard PVC Smooth or PVC XK
EverGuard #2331 Bonding Adhesive (#2331)
Contact (both sides)
1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane)
EverGuard PVC XK Fleeceback
Hot asphalt
Wet lay (substrate)
25 lbs/square
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive (WB181)
Wet lay (substrate)
0.83 to 1.0 gal/square
EverGuard PVC XK Fleeceback
GAF LRF Adhesive M (LRF-M) or LRF Adhesive O
(LRF-O)
Wet lay (substrate)
1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive
ribbons are located directly over the adhesive ribbons used to secure the
insulation when the cover is bonded to insulation less than 1.5-inch thick.
EverGuard PVC XK Fleeceback
GAF 2-Part Roofing Adhesive (GAF 2-Part)
Wet lay (substrate)
“Spatter pattern” at 3.75 lbs/sq.
17. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and RAS 128 for determination of design wind
pressures.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 3 of 34
TABLE 1A: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Roof Cover / Adhesive
MDP
(psf)
LRF-M, OB500
or GAF 2-Part
EverGuard PVC Smooth or
PVC XK / #2331
-52.5
LRF-M, OB500
or GAF 2-Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-52.5
Attach
Type
Attach
See Note 2 (#14
Fastener only)
1 per 2
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
See Note 2 (#14
Fastener only)
1 per 2
ft2
Min. 0.25-inch SECUROCK
Gypsum-Fiber Roof Board
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
W-1.
Min. 19/32-inch plywood or wood plank;
24” spans; 8d ring shank nails 6” o.c.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
W-2.
Min. 19/32-inch plywood or wood plank;
24” spans; 8d ring shank nails 6” o.c.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
TABLE 1B: WOOD DECK - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
W-3.
Deck (See Note 1)
Min. 23/32-inch plywood or
wood plan
Base Insulation Layer
One or more layers, min.
1.5-inch, any combination
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Top Insulation Layer
Type
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
Fasteners
See Note 2
Attach
1 per 2 ft2
Roof Cover / Adhesive
EverGuard PVC-50, -60 or -80 / #2331
MDP
(psf)
-45.0*
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 4 of 34
TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Attachment
Insulation Layer
Fasteners
W-4.
Min. 19/32-inch plywood; 24inch span; 8d ring shank nails
6-inch o.c. at edges and
intermediate supports
One or more layers, any
combination, (Tread Safe =
min. 2-inch)
Drill-Tec #14 Fastener and Drill-Tec
RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe
Plates
W-5.
Min. 19/32-inch plywood over
nominal No. 2 wood trusses
spaced max. 24-inch o.c.; 8d
ring shank nails, 6” o.c. at
edges and 12” o.c. at
intermediate supports.
(Optional) One or more
layers, any combination,
preliminarily attached
(Tread Safe = min. 2-inch
thick insulation)
Drill-Tec #14 (min. 1-inch
embedment) and Drill-Tec
RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe
Plates through to wood supports
Roof Cover
Density
MDP
(psf)
1 per 2.67 ft² (12 parts per 4 x 8 ft board)
Fasteners are 6-, 24- and 42-inches from the
board’s long edge and 12-, 36-, 60- and 84inches from the board’s short edge.
EverGuard PVC XK or EveryGuard PVC
Smooth bonded to Drill-Tec RhinoBond
PVC XHD Plates or Drill-Tec RhinoBond
PVC XHD Tread Safe Plates with
RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-52.5
18-inch o.c. along wood supports, 24-inch o.c.
EverGuard PVC XK or EverGuard PVC
Smooth bonded to Drill-Tec RhinoBond
PVC XHD Plates or Drill-Tec RhinoBond
PVC XHD Tread Safe Plates with
RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-82.5
TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
System
No.
Deck (See Note 1)
Insulation
Type
Roof Cover
Attach
Membrane
Fasteners
Attachment
MDP (psf)
W-6.
Min. 19/32-inch plywood; 24-inch
span; 8d ring shank nails 4-inch o.c.
at edges and intermediate supports
One or more layers,
any combination, min.
0.5-inch
Prelim.
attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2
in. Double Barbed XHD Plates, DrillTec 2-3/8-inch Barbed XHD Plates or
Drill-Tec Eyehook AccuSeam Plate
8-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
W-7.
Min. 19/32-inch plywood; 24-inch
span; 8d ring shank nails 4-inch o.c.
at edges and intermediate supports
One or more layers,
any combination, min.
0.5-inch
Prelim.
attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2
in. Double Barbed XHD Plates, DrillTec 2-3/8-inch Barbed XHD Plates or
Drill-Tec Eyehook AccuSeam Plate
6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 5 of 34
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-1.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
See Note 2
1 per 2 ft2
Additional layers of base insulation
Hot
asphalt
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-2.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
See Note 2
1 per 4 ft2
Additional layers of base insulation
Hot
asphalt
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-3.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-4.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-5.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-6.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
See Note 2
1 per 2 ft2
Min. 0.25-inch thick SECUROCK Gypsum-Fiber
Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-7.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-8.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min 2-inch EnergyGuard RA,
EnergyGuard RN or EnergyGuard RH
See Note 2
1 per 4 ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-9.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-10.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-11.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 0.5-inch Dens Deck
See Note 2
1 per 2 ft2
One or more layers, min. 1.5-inch EnergyGuard
RA, EnergyGuard RN, EnergyGuard RH
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-12.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-13.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-14.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-15.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 6 of 34
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
S-16.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-17.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-18.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-19.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-20.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-21.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
See Note 2
1 per 2 ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-22.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-23.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-24.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-25.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-26.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-27.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-28.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-29.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 7 of 34
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
S-30.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-31.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Additional layers, min. 1.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-32.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Additional layers, min. 1.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
S-33.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-34.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-35.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch
o.c.
-45.0*
S-36.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-37.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-38.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-39.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-40.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-41.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-42.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation
See Note 2
1 per 4 ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-43.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 8 of 34
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
S-44.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-45.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-46.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-47.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-48.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-49.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-50.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
S-51.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-52.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-53.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-54.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-55.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-56.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-57.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 9 of 34
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
S-58.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-59.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-60.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-61.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-62.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9 ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 10 of 34
TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Thermal Barrier
Type
Fasten
Temp Roof
Insulation Layer(s)
Attach
Type
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-63.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RN, EnergyGuard RH
OB500
EverGuard PVC
Smooth or PVC XK /
#2331
-45.0*
S-64.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN
followed by Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC
Smooth or PVC XK /
#2331
-45.0*
S-65.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN
followed by Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC
Smooth or PVC XK /
#2331
-45.0*
S-66.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RH followed by Min.
0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC
Smooth or PVC XK /
#2331
-45.0*
EVERGUARD PVC XK FLEECEBACK APPLICATIONS:
S-67.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RN, EnergyGuard RH
OB500
EverGuard PVC XK
Fleeceback / WB181
-45.0*
S-68.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RN, EnergyGuard RH followed by min. 0.25-inch
Dens Deck Prime or SECUROCK Gypsum-Fiber
Roof Board
OB500
EverGuard PVC XK
Fleeceback / WB181
-45.0*
S-69.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch
SECUROCK GypsumFiber Roof Board
See
Note 2
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RH followed by Min.
0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK
Fleeceback / WB181
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 11 of 34
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck‡ (See Note 1)
Top Insulation Layer
Base Insulation Layer
Type
Fasten
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-70.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard
RH
See
Note 2
1 per 2 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-71.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation
See
Note 2
1 per 2 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-72.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard
RH
See
Note 2
1 per 4 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-73.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso Insulation
See
Note 2
1 per 2.9
ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-74.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch Dens Deck Prime
See
Note 2
1 per 2 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-75.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.5-inch Dens Deck Prime
See
Note 2
1 per 3.2
ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-76.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.625-inch Dens Deck Prime
See
Note 2
1 per 4 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-77.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
See
Note 2
1 per 2 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-78.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
See
Note 2
1 per 2 ft2
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
S-79.
Min. 22 ga., Type B, Grade 33 steel; 6’
spans, 5/8” puddle weld 6” o.c.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso Insulation
See
Note 2
1 per 1.78
ft2
EverGuard PVC Smooth or
PVC XK / #2331
-60.0
S-80.
Min. 22 ga., Type B, Grade 33 steel; 6’
spans, 5/8” puddle weld 6” o.c.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard RH
See
Note 2
1 per 1.78
ft2
EverGuard PVC Smooth or
PVC XK / #2331
-67.5
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-81.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-82.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso Insulation
See
Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
S-83.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
One or more layers, any
combination, min. 1.5inch
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ WB181
-45.0*
Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
S-84.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
(Optional) One or more
layers, any combination
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 12 of 34
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck‡ (See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Roof Cover / Adhesive
MDP
(psf)
S-85.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-86.
Min. 22 ga., Type B, Grade 33 steel; 6’
span, Traxx/5 or Tek/5 screw 6” o.c. or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation or ACFoam IV
See
Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-60.0
S-87.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch Dens Deck Prime
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
-45.0*
S-88.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-89.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-90.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard RH, EnergyGuard RN
See
Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-91.
Min. 22 ga., Type B, Grade 33 steel; 6’
span, Traxx/5 or Tek/5 screw 6” o.c. or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See
Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-60.0
S-92.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch Dens Deck Prime
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-93.
Min. 22 ga., Type B, Grade 33 steel; 6’
span, Traxx/5 or Tek/5 screw 6” o.c. or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board
See
Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-67.5
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
S-94.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-95.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH,
EnergyGuard RN
See
Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-96.
Min. 22 ga., Type B, Grade 33 steel; 6’
span, Traxx/5 or Tek/5 screw 6” o.c. or
struct conc.
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See
Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-60.0
S-97.
Min. 22 ga., Type B, Grade 33 steel or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.25-inch Dens Deck Prime
See
Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-45.0*
S-98.
Min. 22 ga., Type B, Grade 33 steel; 6’
span, Traxx/5 or Tek/5 screw 6” o.c. or
struct conc.
(Optional) One or more
layers, any combination
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board
See
Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-67.5
‡ NOTE: As-tested steel deck performance under TAS 114, Appendix J indicates steel deck at max. 6’ spans attached with 5/8” diameter puddle welds spaced 6” o.c. may be substituted for Tek/5 screws or Traxx/5 screws in
the Table 2B-1A assemblies up to a maximum design pressure of -82.5 psf. See Note 1.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 13 of 34
TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Deck
Base Insulation Layer
No.
(See Note 1)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
Min. 0.625-inch Dens Deck or min. 0.5-inch SECUROCK Glass-Mat Roof Board, loose-laid,
Min. 22 ga., Type
followed by UnderRoof 2 Polyester-Surfaced Leak Barrier, UnderRoof HT High
S-99.
B, Grade 33 steel
Temperature Leak Barrier or WeatherWatch XT Mat Surfaced Leak Barrier, self-adhered,
or struct conc.
followed by min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN, loose-laid
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-100.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-101.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-102.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-103.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-104.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
Min. 22 ga., Type
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
S-105.
B, Grade 33 steel
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfor struct conc.
adhered
S-106.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Top Insulation Layer
Type
Roof Cover /
Adhesive
MDP
(psf)
1 per 4
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 2
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 4
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 2
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per
3.2 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 4
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 2
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 2
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
See
Note 2
1 per 2
ft2
EverGuard PVC XK
Fleeceback /
WB181
-45.0*
Fasten
Attach
Min. 0.625-inch Dens Deck Prime
See
Note 2
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
Min. 2-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH, loose
laid, followed by min. 0.25-inch Dens
Deck Prime
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH, loose
laid, followed by min. 0.5-inch Dens
Deck Prime
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH, loose
laid, followed by min. 0.625-inch Dens
Deck Prime
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH, loose
laid, followed by min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board
Min. 1.5-inch EnergyGuard RH, loose
laid, followed by min. 0.5-inch
EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-107.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board,
loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2
Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 1.5-inch EnergyGuard RH, loose
laid, followed by min. 0.5-inch
EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 14 of 34
TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER
Deck‡
(See Note 1)
Insulation Layer
S-108.
S-109.
System
No.
Attachment
Fasteners
Density
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5inch; (Tread Safe = min. 2inch)
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC
XHD Tread Safe Plates
1 per 5.3 ft² (6 parts per 4 x 8 ft board)
Fasteners located in each of the four corners of the
board and at mid-span of the 96-inch length. Fasteners
are 6-inches from the board’s long edges and 12-inches
and 48-inches from the board’s short edges.
Min. 22 ga., Type B,
Grade 33 steel; 6’
span, Traxx/5 or
Tek/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Drill-Tec SXHD and Drill-Tec
RhinoBond PVC XHD Plates
24 x 36 inch grid
Roof Cover
MDP (psf)
EverGuard PVC-50, -60 or -90 bonded to Drill-Tec
RhinoBond PVC XHD Plates or Drill-Tec
RhinoBond PVC XHD Tread Safe Plates with
RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-45.0*
EverGuard PVC XK bonded or EverGuard PVC
Smooth to Drill-Tec RhinoBond PVC XHD Plates
with RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-45.0
1 per 4 ft² (8 parts per 4 x 8 ft board)
S-110.
Min. 20 ga., type B,
Grade 33 steel; 7’
span, 5/8” puddle
weld 6” o.c.
One or more layers, any
combination, min. 1-inch;
(Tread Safe = min. 2-inch)
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC
XHD Tread Safe Plates
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
S-111.
Min. 22 ga., Type B,
Grade 33 steel; 6’
span, Traxx/5 or
Tek/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Drill-Tec SXHD and Drill-Tec
RhinoBond PVC XHD Plates
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
with RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-60.0
S-112.
Min. 22 ga., type B,
Grade 33 steel; 6 ft
span; 5/8” puddle
welds, 6” o.c.
One or more layers, any
combination, (Tread Safe =
min. 2-inch)
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC
XHD Tread Safe Plates
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
-67.5
24 x 24 inch grid
1 per 2.67 ft² (12 parts per 4 x 8 ft board)
Fasteners are 6-, 24- and 42-inches from the board’s
long edge and 12-, 36-, 60- and 84-inches from the
board’s short edge.
-52.5
‡ NOTE: As-tested steel deck performance under TAS 114, Appendix J indicates steel deck at max. 6’ spans attached with 5/8” diameter puddle welds spaced 6” o.c. may be substituted for Tek/5 screws or Traxx/5 screws in
the Table C-2 assemblies up to a maximum design pressure of -67.5 psf. See Note 1.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 15 of 34
TABLE 2C: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
System
No.
Deck (See Note 1)
Insulation
Type
Roof Cover
Attach
Membrane
Fasteners
Attachment
MDP (psf)
EVERGUARD PVC-50, -60 OR -80:
S-113.
Min. 22 ga., type B, Grade 80 steel;
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
Attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates
12-inch o.c. within 5.5-inch wide laps spaced
75.5-inch o.c. and sealed with a 1.5-inch heat
weld.
-45.0
S-114.
Min. 22 ga., type B, Grade 33 steel;
7’ spans, 5/8” puddle weld 12” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
Attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2inch Barbed Plates
6-inch o.c. within 6-inch wide laps spaced 75inch o.c. and sealed with a 1.5-inch heat weld.
-52.5
S-115.
Min. 22 ga., type B, Grade 80 steel;
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
Attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates
6-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld.
-75.0
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK:
S-116.
Min. 22 ga., type B, Grade 33 steel;
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
Attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec #14 Fasteners with
Drill-Tec 2 in. Barbed Plates
6-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 2-inch heat weld.
-45.0
S-117.
Min. 22 ga., type B, Grade 80 steel’
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates
6-inch o.c. within minimum 5.5-inch wide laps
spaced maximum 75.5-inch o.c. and sealed with
a 2-inch heat weld
-45.0
S-118.
Min. 22 ga., type B, Grade 80 steel’
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec SXHD #21 with DrillTec 2 ¾ in. Barbed SXHD
Plates
12-inch o.c. within minimum 6-inch wide laps
spaced maximum 75-inch o.c. and sealed with a
2-inch heat weld
-45.0
S-119.
Min. 22 ga., type B, Grade 33 steel;
6’ spans, Traxx/5 screw 6” o.c.
One or more layers, any
combination, min. 1.5-inch
Prelim.
Attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 23/8-inch Barbed XHD Plates
6-inch o.c. within 6-inch wide laps spaced 114inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 16 of 34
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Vapor Barrier
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC-50, -60 or -80 APPLICATIONS:
C-1.
Struct conc.
(Optional) See Note A
below
Min. 1-inch EnergyGuard RA
OB500
None
N/A
EverGuard PVC-50, -60 or -80 /
#2331
-325.0*
C-2.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, ACFoam III
OB500
Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC-50, -60 or -80 /
#2331
-240.0*
C-3.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, ACFoam III
GAF 2Part
Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board
GAF 2Part
EverGuard PVC-50, -60 or -80 /
#2331
-240.0*
EVERGUARD PVC SMOOTH OR PVC XK / EVERGUARD #2331 BONDING ADHESIVE:
C-4.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
C-5.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
OB500
(Optional) Additional layer of base insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-247.5*
C-6.
Struct conc.
D41 or Matrix #307 &
UnderRoof 2 PolyesterSurfaced Leak Barrier
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-97.5*
C-7.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-97.5*
C-8.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
C-9.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-247.5*
C-10.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
C-11.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
C-12.
Struct conc.
None
Min. 1-inch EnergyGuard RH
LRF-M
(Optional) Additional layer of base insulation
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-162.5*
C-13.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
C-14.
Struct conc.
None
Min. 1.5-inch EnergyGuard RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-97.5*
C-15.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 17 of 34
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
(See Note 1)
C-16.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
C-17.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1-inch EnergyGuard
RA, EnergyGuard RH, EnergyGuard RN
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
C-18.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1-inch EnergyGuard
RA, EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
GAF 2Part
EverGuard PVC Smooth or PVC
XK / #2331
-232.5*
C-19.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1-inch EnergyGuard
RA, EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2Part
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
Min. 1-inch EnergyGuard RH
HA
(Optional) Additional layers of base insulation
HA
EverGuard PVC XK Fleeceback /
Hot asphalt
-490.0*
Deck
Vapor Barrier
Type
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC XK FLEECEBACK IN HOT ASPHALT:
C-20.
Struct conc.
(primed)
None
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
C-21.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard
RA, EnergyGuard RH or EnergyGuard RN
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-90.0*
C-22.
Struct conc.
D41 or Matrix #307 &
UnderRoof 2 PolyesterSurfaced Leak Barrier
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-97.5*
C-23.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-97.5*
C-24.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard
RA, EnergyGuard RH or EnergyGuard RN
OB500
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-90.0*
C-25.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-90.0*
C-26.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-90.0*
C-27.
Struct conc.
None
Min. 1.5-inch EnergyGuard RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-97.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 18 of 34
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
(See Note 1)
C-28.
Struct conc.
C-29.
Struct conc.
Deck
Base Insulation Layer
Vapor Barrier
Top Insulation Layer
Roof Cover / Adhesive
MDP
(psf)
GAF 2Part
EverGuard PVC XK Fleeceback /
WB181
-90.0*
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
WB181
-90.0*
Type
Attach
Type
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard
RA, EnergyGuard RH or EnergyGuard RN
GAF 2Part
(Optional) Additional layers of base insulation
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard
RA, EnergyGuard RH or EnergyGuard RN
GAF 2Part
Attach
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
C-30.
Struct conc.
(Optional) See Note A
below
Min. 1-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 6-inch o.c.
-45.0*
C-31.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-60.0*
C-32.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH
OB500
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK Fleeceback /
LRF-O, 12-inch o.c.
-45.0*
C-33.
Struct conc.
(Optional) See Note A
below
(Optional) Min. 1-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M, 6-inch o.c.
-45.0*
C-34.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
C-35.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
OB500
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-36.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-37.
Struct conc.
(Optional) See Note A
below
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
None
N/A
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-195.0*
C-38.
Struct conc.
None
Min. 1-inch EnergyGuard RH
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M, 6-inch o.c.
-45.0*
C-39.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-60.0*
C-40.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback /
LRF-O, 12-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 19 of 34
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
(See Note 1)
Roof Cover / Adhesive
MDP
(psf)
C-41.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
C-42.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-43.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
LRF-M
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-44.
Struct conc.
None
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
None
N/A
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-195.0*
C-45.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-60.0*
C-46.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-O, 12-inch o.c.
-45.0*
C-47.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
C-48.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-49.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-180.0*
C-50.
Struct conc.
(Optional) See Note A
below
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
None
N/A
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-195.0*
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-60.0*
Deck
Vapor Barrier
Type
Attach
Type
Attach
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
C-51.
Struct conc.
(Optional) See Note A
below
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 0.5-inch EnergyGuard Polyiso
Insulation
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 20 of 34
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
(See Note 1)
Roof Cover / Adhesive
MDP
(psf)
C-52.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
OB500
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
C-53.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
C-54.
Struct conc.
(Optional) See Note A
below
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
None
N/A
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-195.0*
C-55.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-60.0*
C-56.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
LRF-M
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
C-57.
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
LRF-M
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
C-58.
Struct conc.
None
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
None
N/A
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-195.0*
C-59.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-60.0*
C-60.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
GAF 2Part
Optional additional layers base insulation followed
by min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
C-61.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt
Primer & Ruberoid HW
Smooth or Ruberoid
HW 25 Smooth, torch
applied
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-180.0*
C-62.
Struct conc.
(Optional) See Note A
below
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
None
N/A
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-195.0*
Deck
Vapor Barrier
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Attach
Type
Attach
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 21 of 34
A.
The following are options for installation of an optional vapor barrier / temporary roof on the concrete deck prior to insulation placement. If vapor barrier / temp roof is installed, concrete deck shall be primed with
Matrix 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation
adhesive noted below.
1.
2.
3.
For use with OB500 applied insulation:
One or two plies, asphalt-applied GAF base and/or ply sheet:
Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage:
Ruberoid Torch Smooth, heat welded:
Ruberoid HW 25 Smooth, heat welded:
Ruberoid HW Smooth, heat welded:
UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered:
MDP -352.5 psf
MDP -202.5 psf
MDP -165.0 psf
MDP -180.0 psf
MDP -232.5 psf
MDP -127.5 psf
For use with GAF 2-Part applied insulation:
One or two plies, asphalt-applied GAF base ply and/or ply:
Optional asphalt-applied GAF base ply, ply or base membrane with asphalt-applied GAF SBS cap membrane:
Optional asphalt-applied GAF base ply, ply or base membrane or heat-welded GAF base membrane with heat-welded GAF SBS or APP cap membrane:
Optional self-adhering Liberty base membrane with Liberty cap membrane:
Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded:
For use with GAF LRF-Adhesive M:
Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded:
MDP -262.5 psf
MDP -270.0 psf
MDP -169.0 psf
MDP -250.0 psf
MDP -180.0 psf
MDP -180.0 psf
TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System No.
Roof Deck
Roof Cover / Adhesive
MDP (psf)
C-63.
Struct conc.
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c.
-45.0*
C-64.
Struct conc. primed with Matrix #307
EverGuard PVC XK Fleeceback / Hot asphalt at 25 lbs/square
-502.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 22 of 34
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Deck (See Note 1)
System
No.
Roof
Deck
Base Insulation Layer
LWIC (See Note 15)
Type
Coverboard
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
LWC-1.
Struct.
conc.
Min. 200 psi, min. 2inch thick Elastizell
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
OB500
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC-50, -60 or -80
/ #2331
-225.0*
LWC-2.
Struct.
conc.
Min. 200 psi, min. 2inch thick Elastizell
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-180.0*
LWC-3.
Struct.
conc.
Min. 200 psi, min. 2inch thick Celcore
Cellular Concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-222.5*
LWC-4.
Struct.
conc.
Min. 200 psi, min. 2inch thick Mearlcrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-240.0*
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Roof Deck (See Note 1)
Structural Deck
LWIC (See Note 15)
Base Sheet
Roof Cover
Type
Fasteners
Attach
Base
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth
Drill-Tec Base Sheet
Fastener (1.7 in), Drill-Tec
Base Sheet Fastener E (1.7
in), Drill-Tec Locking Impact
Nail or Trufast FM-290
7-inch o.c. at min. 4-inch
laps and 7-inch o.c. in
two, equally spaced,
staggered center rows
(Optional) One or two plies Ruberoid
20 Smooth, Ruberoid Mop Smooth,
Ruberoid Mop Smooth 1.5 or
Ruberoid Mop Plus Smooth in hot
asphalt or one or two plies Ruberoid
HW 25 Smooth or Ruberoid HW
Smooth, torch-applied
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base Sheet,
Ruberoid 20 Smooth
Drill-Tec Base Sheet
Fastener (1.7 in), Drill-Tec
Base Sheet Fastener E (1.7
in), Drill-Tec Locking Impact
Nail or Trufast FM-290
7-inch o.c. at min. 4-inch
laps and 7-inch o.c. in
two, equally spaced,
staggered center rows
One or two plies Ruberoid 20
Smooth, Ruberoid Mop Smooth,
Ruberoid Mop Smooth 1.5 or
Ruberoid Mop Plus Smooth in hot
asphalt or one or two plies Ruberoid
HW 25 Smooth or Ruberoid HW
Smooth, torch-applied
Cap
MDP
(psf)
HYBRID SYSTEMS:
LWC-5.
LWC-6.
Min. 22 ga., type
BV, 40 ksi; 6 ft
spans; 5/8”
puddle welds or
Traxx/5 screws 6”
o.c.
Min. 340 psi, min. 2-inch thick cellular
lightweight concrete. Note: To qualify
Min. 22 ga., type
BV, 40 ksi; 6 ft
spans; 5/8”
puddle welds or
Traxx/5 screws 6”
o.c.
Min. 340 psi, min. 2-inch thick cellular
lightweight concrete. Note: To qualify
the LWC under this assembly, the selected
fastener shall achieve an average
withdrawal of 60 lbf or greater when
tested per TAS105 or ANSI/SPRI FX-1
the LWC under this assembly, the selected
fastener shall achieve an average
withdrawal of 60 lbf or greater when
tested per TAS105 or ANSI/SPRI FX-1
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
EverGuard
PVC XK
Fleeceback in
-52.5
hot apshalt
EverGuard
PVC XK
Fleeceback in
GAF 2-Part,
spatterapplied
-52.5
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 23 of 34
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
Roof Deck
System
No.
Roof Cover
Min. Compressive
Strength (psi)
Min. Thick
(in.)
Membrane
Adhesive
MDP
(psf)
300
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5*
180
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5*
180
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-102.5*
LWIC (See Note 15)
Structural Deck
Type
LWC-7.
Min. 22 ga., type BV,
Grade 33 steel; 6’ spans,
5/8” puddle welds 6” o.c.
LWC-8.
Min. 22 ga., type BV, Grade
33 steel; 6’ spans, 5/8-inch
puddle welds, 6” o.c.
LWC-9.
Structural concrete
LWC-10.
Structural concrete
Elastizell
220
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-200.0*
LWC-11.
Structural concrete
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-205.0*
LWC-12.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-225.0*
LWC-13.
Structural concrete
Elastizell
300
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 6-inch o.c.
-45.0*
LWC-14.
Structural concrete
Mearlcrete
730
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 6-inch o.c.
-45.0*
180
2
EverGuard PVC XK Fleeceback
LRF-M, ribbons 6-inch o.c.
-92.5*
180
2
EverGuard PVC XK Fleeceback
LRF-O, ribbons 6-inch o.c.
-112.5*
Mearlcrete
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
LWC-15.
Structural concrete
LWC-16.
Structural concrete
LWC-17.
Min. 22 ga., type BV,
Grade 33 steel; 6’ spans,
5/8” puddle welds 6” o.c.
Mearlcrete
300
2
EverGuard PVC XK Fleeceback
LRF-M, 4-inch o.c.
-52.5*
LWC-18.
Structural concrete
Elastizell
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-210.0*
LWC-19.
Structural concrete
Mearlcrete or Insulcel
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-270.0*
LWC-20.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
LRF-M, 4-inch o.c.
-225.0*
LWC-21.
Structural concrete
Celcore Cellular Concrete
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-300.0*
Cellular lightweight insulating concrete; Note: To qualify
LWC-22.
Min. 22 ga., type BV, Grade
33 steel; 6’ spans, 5/8-inch
puddle welds, 6” o.c.
180
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5*
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 24 of 34
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
Roof Deck
System
No.
Roof Cover
LWIC (See Note 15)
Structural Deck
Type
Min. Compressive
Strength (psi)
Min. Thick
(in.)
Membrane
Adhesive
MDP
(psf)
LWC-23.
Min. 22 ga., type BV,
Grade 33 steel; 6’ spans,
5/8” puddle welds 6” o.c.
Mearlcrete
300
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5*
LWC-24.
Min. 22 ga., 33 ksi, type BV
(0.5%) steel; 6’ spans, 5/8”
puddle welds 6” o.c.
Elastizell
200
3
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-60.0*
180
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-102.5
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener
(1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall
achieve MCRF of 97 lbf or greater when tested per TAS105.
LWC-25.
Structural concrete
LWC-26.
Structural concrete
Elastizell
220
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-200.0*
LWC-27.
Structural concrete
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-205.0*
LWC-28.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-225.0*
LWC-29.
Structural concrete
Insulcel
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-270.0*
LWC-30.
Structural concrete
Celcore Cellular Concrete
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-300.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 25 of 34
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
CWF-1.
Min. 2-inch Tectum Plank or
Tectum LS Plank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, ACFoam III
OB500
(Optional) Additional layers of base
insulation
OB500
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
CWF-2.
Min. 2-inch Tectum Plank or
Tectum LS Plank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, ACFoam III
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
CWF-3.
Min. 2-inch Tectum Plank or
Tectum LS Plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH, EnergyGuard
RN
OB500
(Optional) Additional layers of base
insulation
OB500
EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c.
-45.0*
CWF-4.
Min. 2-inch Tectum Plank or
Tectum LS Plank
(Optional) Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c.
-45.0*
CWF-5.
Min. 2-inch Tectum Plank or
Tectum LS Plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RH
LRF-M
(Optional) Additional layers of base
insulation
LRF-M
EverGuard PVC XK Fleeceback / LRFM, 12-inch o.c.
-45.0*
CWF-6.
Min. 2-inch Tectum Plank or
Tectum LS Plank or
Fibroplank
Min. 1.5-inch thick EnergyGuard Polyiso
Insulation, EnergyGuard RA or ACFoam III
GAF 2-Part
(Optional) Additional layer of Base
Insulation
GAF 2-Part
EverGuard PVC Smooth or PVC XK /
#2331
-52.5*
CWF-7.
Min. 2-inch Tectum Plank or
Tectum LS Plank or
Fibroplank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part
EverGuard PVC Smooth or PVC XK /
#2331
-52.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 26 of 34
TABLE 6A: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Deck
(See Notes 1 & 12)
G-1.
Existing poured gypsum or
gypsum plank
Min. 1-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
(Optional) Additional layers of base
insulation
G-2.
Existing poured gypsum or
gypsum plank
Min. 1-inch EnergyGuard RA
OB500
G-3.
Existing poured gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RN, ACFoam III
G-4.
Existing poured gypsum or
gypsum plank
G-5.
Existing poured gypsum or
gypsum plank
Roof Cover / Adhesive
MDP (psf)
OB500
EverGuard PVC XK Fleeceback / LRF-M,
6-inch o.c.
-45.0*
None
N/A
EverGuard PVC-50, -60 or -80 / #2331
-262.5*
OB500
Min. 0.25-inch Dens Deck or
SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC-50, -60 or -80 / #2331
-112.5*
Min. 1-inch EnergyGuard RH
LRF-M
None
N/A
EverGuard PVC Smooth / #2331
-352.5*
Min. 1.5-inch EnergyGuard RA, EnergyGuard
RN, ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part
EverGuard PVC-50, -60 or -80 / #2331
-240.0*
Type
Attach
Type
Attach
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Notes 1 &
11)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR PVC XK APPLICATIONS:
G-6.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-7.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-8.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-9.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-10.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 288 lbf)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 27 of 34
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Notes 1 &
11)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
G-11.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation or
min. 1.5-inch EnergyGuard RH
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-12.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation or
min. 1.5-inch EnergyGuard RH
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-13.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard RH
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-14.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard RH
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-15.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 288 lbf)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
EVERGUARD PVC XK FLEECEBACK APPLICATIONS:
G-16.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-17.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-18.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-19.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-20.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 288 lbf)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 28 of 34
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Notes 1 &
11)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
G-21.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation or
min. 1.5-inch EnergyGuard RH
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-22.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation or
min. 1.5-inch EnergyGuard RH
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-23.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 180 lbf)
1 per 2
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard RH
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-24.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation or
EnergyGuard RH
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 261 lbf)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation or min. 1.5-inch EnergyGuard RH
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-25.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation
Drill-Tec Polymer Gyptec with DrillTec 3” Gyptec Plates (Min. 2-inch
embedment) (MCRF > 288 lbf)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 29 of 34
TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
Deck
(See Notes 1 & 11)
System
No.
Base Insulation Layer
Top Insulation Layer
Type
Fasteners
Attach
Roof Cover / Adhesive
MDP
(psf)
G-26.
Existing poured
gypsum or gypsum
plank
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec
Plates (Min. 2-inch embedment) (MCRF > 180 lbf)
1 per 2 ft2
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
G-27.
Existing poured
gypsum or gypsum
plank
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec
Plates (Min. 2-inch embedment) (MCRF > 261 lbf)
1 per 2.9 ft2
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
G-28.
Existing poured
gypsum or gypsum
plank
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec
Plates (Min. 2-inch embedment) (MCRF > 180 lbf)
1 per 2 ft2
EverGuard PVC XK Fleeceback / WB181
or LRF-M or LRF-O, 12-inch o.c.
-45.0*
G-29.
Existing poured
gypsum or gypsum
plank
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec
Plates (Min. 2-inch embedment) (MCRF > 261 lbf)
1 per 2.9 ft2
EverGuard PVC XK Fleeceback / WB181
or LRF-M or LRF-O, 12-inch o.c.
-45.0*
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System No.
Deck (See Notes 1 & 12)
Roof Cover / Adhesive
MDP (psf)
G-30.
Existing poured gypsum or gypsum plank
EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c.
-45.0*
G-31.
Existing poured gypsum or gypsum plank
EverGuard PVC XK Fleeceback / LRF-O, 6-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 30 of 34
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(See Notes 1 & 12)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
EVERGUARD PVC APPLICATIONS:
R-1.
Existing asphaltic BUR or mineral surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, ACFoam III
OB500
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC-50, -60 or -80 /
#2331
-120.0*
R-2.
Existing asphaltic BUR or mineral surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, ACFoam III
GAF 2Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC-50, -60 or -80 /
#2331
-240.0*
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
R-3.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation
OB500
None
N/A
EverGuard PVC Smooth or PVC
XK / #2331
-45.0*
R-4.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
None
N/A
EverGuard PVC Smooth or PVC
XK / #2331
-225.0*
R-5.
Existing smooth surfaced BUR / APP modified
bitumen or granule surface roof cover over
struct conc. deck
(Optional) Min. 1.5-inch
EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-97.5*
R-6.
Existing asphaltic BUR or mineral surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-120.0*
R-7.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-225.0*
R-8.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
R-9.
Existing asphaltic BUR or mineral surface cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC
XK / #2331
-120.0*
R-10.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC Smooth or PVC
XK / #2331
-45.0*
R-11.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC Smooth or PVC
XK / #2331
-75.0*
R-12.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC Smooth or PVC
XK / #2331
-225.0*
R-13.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-75.0*
R-14.
Existing smooth surfaced BUR or granule
surface roof cover
(Optional) Min. 1.5-inch
EnergyGuard RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-75.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 31 of 34
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Substrate
(See Notes 1 & 12)
R-15.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Min. 0.25-inch Dens Deck Prime
R-16.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
R-17.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
Type
Roof Cover / Adhesive
MDP (psf)
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-225.0*
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-75.0*
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth or PVC
XK / #2331
-202.5*
Attach
Type
Attach
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN WB181 BONDING ADHESIVE:
R-18.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
None
N/A
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
R-19.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
R-20.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
R-21.
Existing smooth surfaced BUR / APP modified
bitumen or granule surface roof cover over
struct conc. deck
(Optional) Min. 1.5-inch
EnergyGuard RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-97.5*
R-22.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC XK Fleeceback
/ WB181
-75.0*
R-23.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
R-24.
Existing smooth surfaced BUR or granule
surface roof cover
(Optional) Min. 1.5-inch
EnergyGuard RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-75.0*
R-25.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-75.0*
R-26.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
R-27.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-75.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 32 of 34
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(See Notes 1 & 12)
R-28.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen over struct conc. deck
Base Insulation Layer
Type
Min. 0.5-inch EnergyGuard Polyiso
Insulation
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-90.0*
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN LRF ADHESIVE M OR LRF ADHESIVE O:
R-29.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation
OB500
None
N/A
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
R-30.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation or ACFoam IV
OB500
None
N/A
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-60.0*
R-31.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
-45.0*
R-32.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
R-33.
Existing smooth- or granule-surfaced BUR;
smooth- or granule-surfaced SBS modified
bitumen or granule-surfaced APP modified
bitumen over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0*
R-34.
Existing granule-surfaced BUR, granulesurfaced modified bitumen or smooth-surfaced
SBS modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation
LRF-M
None
N/A
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
R-35.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct
conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation or ACFoam IV
LRF-M
None
N/A
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-60.0*
R-36.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct
conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
-45.0*
R-37.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct
conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 33 of 34
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Substrate
(See Notes 1 & 12)
R-38.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
R-39.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Type
Roof Cover / Adhesive
MDP (psf)
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0*
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0*
Attach
Type
Attach
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN GAF 2-PART ROOFING ADHESIVE:
R-40.
Existing smooth- or granule-surfaced BUR;
smooth- or granule-surfaced SBS modified
bitumen or granule-surfaced APP modified
bitumen over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0*
R-41.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0*
R-42.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch
EnergyGuard Polyiso Insulation,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0*
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Substrate (See Notes 1 & 12)
Roof Cover / Adhesive
MDP (psf)
R-43.
Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c.
-45.0*
R-44.
Existing asphaltic granule surfaced roof cover over steel deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c.
-60.0*
R-45.
Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP
modified bitumen over steel deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c.
-60.0*
R-46.
Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP
modified bitumen over structural concrete deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c.
-337.5*
R-47.
Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-45.0
R-48.
Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified
bitumen over steel deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-60.0*
R-49.
Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified
bitumen over structural concrete deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-337.5*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.12.13-4-R9 for FL16739-R8
Revision 9: 12/15/2015
Appendix 1, Page 34 of 34
Download