FL #
FL3443-R18
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer
GAF
Address/Phone/Email
1 Campus Drive
Parisppany, NJ 07054
(973) 872-4421
lindareith@trinityerd.com
Authorized Signature
Beth McSorley
lindareith@trinityerd.com
Technical Representative
Beth McSorley (current)
Address/Phone/Email
1 Campus Drive
Parsippany, NJ 07054
(973) 872-4421
bmcsorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Single Ply Roof Systems
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Robert Nieminen
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
08/07/2016
Validated By
John W. Knezevich, PE

Certificate of Independence
Referenced Standard and Year (of Standard)
Validation Checklist - Hardcopy Received
FL3443_R18_COI_2016_01_COI_Nieminen.pdf
Standard
Year
ASTM D4434
2009
FM 4470
1992
FM 4474
2004
TAS 114
2011
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvbK%2bEQBZ... 4/15/2016
Florida Building Code Online
Page 2 of 2
Product Approval Method
Method 1 Option D
Date Submitted
02/14/2016
Date Validated
02/16/2016
Date Pending FBC Approval
02/17/2016
Date Approved
04/12/2016
Summary of Products
FL #
Model, Number or Name
Description
3443.1
EverGuard PVC Single-Ply Roof
Systems
Internally reinforced thermoplastic roof covers
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-502.5
Other: 1.) The design pressure noted in this application
pertains to one specific assembly over one specific deck
type. Refer to the ER Appendix for all deck types, systems
and maximum design pressures. 2.) Refer to ER Section 5
for Limits of Use.
Back
Installation Instructions
FL3443_R18_II_2016_02_FINAL_A1_ER_GAF_PVC_FL3443R18.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL3443_R18_AE_2016_02_FINAL_ER_GAF_PVC_FL3443R18.pdf
Created by Independent Third Party: Yes
Next
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvbK%2bEQBZ... 4/15/2016
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street, Unit 13
Oxford, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF
1 Campus Drive
Parsippany, NJ 07054
Evaluation Report 01506.09.04-R21
FL3443-R18
Date of Issuance: 07/20/2005
Revision 21: 02/12/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: EverGuard® PVC Single-Ply Roof Membrane Systems
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words “TRINITY|ERD Evaluated” may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5, plus a 39-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facimilie seal appearing was authorized by Robert Nieminen, P.E.
on 02/12/2016. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in
any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEMS EVALUATION:
1.
SCOPE:
Product Category:
Roofing
Sub-Category:
Single Ply Roof Systems
®
Compliance Statement: EverGuard PVC Single-Ply Roof Membrane Systems, as produced by GAF, have
demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with
the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
2.
3.
STANDARDS:
Section
Property
Standard
Year
1504.3.1
1504.7
1507.13.2
1523.6.2
Wind
Impact
Physical Properties
Wind
FM 4474
FM 4470
ASTM D4434
TAS 114
2004
1992
2009
2011
Entity
Examination
Reference
Date
ATI (TST1558)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ACRC (TST4671)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
FET (TST7393)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
Physical Properties
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
TAS 114
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
FM 4470 / 4474
FM 4470 / 4474
TAS 114
FM 4470
FM 4470
FM 4470
52825.01-106-31
06-047
07-001
07-002
07-007
07-029
07-031
08-031
11-057
11-058
11-059
11-060
11-061
11-062
11-063
11-066
12-005
12-006
12-007
12-009
12-010
12-011
12-021
12-022
12-017
12-020
12-027
12-028
12-032
11-015-R1
11-018-R1
11-022-R1
F35940.10.11-2-R2
F35940.12.11-R2
F42130.06.13
F42130.06.13-1
F42130.09.13
GAF-SC8580.14
GAF-SC8580.14
08-050182
3003956
3003955
3014692
06/15/2005
12/21/2006
01/12/2007
01/12/2007
01/19/2007
03/08/2007
05/09/2007
05/05/2008
09/30/2011
10/03/2011
10/04/2011
10/05/2011
10/06/2011
10/07/2011
10/08/2011
11/21/2011
04/09/2012
04/09/2012
04/10/2012
04/20/2012
04/20/2012
04/20/2012
04/26/2012
04/26/2012
05/07/2012
05/08/2012
05/22/2012
05/22/2012
08/23/2012
08/29/2012
08/29/2012
08/29/2012
02/27/2012
02/27/2012
06/05/2013
06/05/2013
09/13/2013
03/25/2015
07/20/2015
06/26/2008
02/18/2000
03/05/2002
08/05/2003
REFERENCES:
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.09.04-R21
FL3443-R18
Revision 21: 02/12/2016
Page 2 of 5
Entity
Examination
Reference
Date
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
FM Approvals (TST1867)
IRT (TST5296)
MTI (TST2508)
MTI (TST2508)
MTI (TST2508)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
PRI (TST5878)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
UL, LLC. (QUA9625)
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
TAS 114
ASTM D4434
ASTM D4434
ASTM D4434
Physical Properties
Component Performance
Component Performance
Component Performance
Component Performance
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
Comparative Pull-Off
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
FM 4470 / 4474
Quality Control
Quality Control
Quality Control
Quality Control
3024709
3023368
3028606
3026964
3031127
3033126
3034394
3037879
797-07043-267
3044862
3044914
3045789
3046328
3041769
3046403
797-07886-267
797-07849-267
3046054
3047606
3048122
797-08217-267
3047237
3047636
797-08873-267
3048066
797-09116-267
797-09495-267
797-09594-267
797-09892-267
04-006
NX21J0A
NX21J0B
NX21J0C
GAF-373-02-01
GAF-462-02-01
GAF-462-02-02
GAF-462-02-03
GAF-462-02-04
GAF-457-02-02
GAF-457-02-04
GAF-457-02-06
GAF-457-02-07
GAF-457-02-08
GAF-435-02-01
GAF-435-02-11
GAF-510-02-02
GAF-515-02-01
GAF-515-02-03
GAF-516-02-03
GAF-525-02-02
GAF-525-02-03
GAF-462-02-07
GAF-462-02-08
GAF-462-02-09
GAF-462-02-10
GAF-462-02-11
GAF-538-02-03
ML File No. R1306, R9228
ML File No. R1306, R21864
Inspection Report, PA
Inspection Report, NJ
10/21/2005
03/20/2006
02/23/2007
07/25/2007
10/01/2007
07/11/2008
02/27/2009
02/04/2010
01/16/2012
05/11/2012
06/18/2012
07/12/2012
09/13/2012
09/27/2012
09/28/2012
11/21/2012
12/03/2012
12/21/2012
02/26/2013
04/29/2013
05/01/2013
07/15/2013
08/08/2013
11/26/2013
12/13/2013
01/24/2014
05/27/2014
06/24/2014
08/12/2014
02/16/2004
06/01/2011
07/20/2011
06/01/2011
10/15/2012
11/15/2013
11/18/2013
11/18/2013
11/18/2013
01/20/2014
01/24/2014
01/24/2014
01/24/2014
01/24/2014
01/29/2014
01/29/2014
04/08/2014
05/13/2014
05/13/2014
05/13/2014
06/23/2014
06/23/2014
07/01/2014
07/01/2014
07/01/2014
07/01/2014
07/01/2014
08/13/2014
01/27/2015
03/11/2015
08/07/2015
11/20/2015
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.09.04-R21
FL3443-R18
Revision 21: 02/12/2016
Page 3 of 5
4.
PRODUCT DESCRIPTION:
This Evaluation Report covers EverGuard® PVC Single-Ply Roof Membrane Systems installed in accordance with GAF
published installation instructions and the Limitations / Conditions of Use herein.
®
®
®
 EverGuard PVC-50, EverGuard PVC-60 and EverGuard PVC-80 membranes are nominal 50-mil (1.3 mm), 60-mil
(1.5-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (PVC) roof covers, available in 81 and 40.5inch wide rolls.
®
 EverGuard PVC Smooth membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick,
polyester scrim reinforced, thermoplastic (PVC) single-ply roof membranes, available in 120 and 60-inch wide rolls.
®
 EverGuard PVC XK membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic
®
fiber reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membranes, available in 120 and 60-inch wide rolls.
®
 EverGuard PVC XK Fleeceback membranes are nominal 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic fiber
®
reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membrane with a nonwoven polyester felt backing,
available in 120 and 76-inch wide rolls.
5.
LIMITATIONS:
5.1
This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2
This Evaluation Report is not for use in HVHZ.
5.3
Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4
For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 or 2603.6 apply.
5.5
The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
5.6
For recover installations, the existing roof shall be examined in accordance with FBC 1510.
5.7
For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to
resist the elevated pressure criteria. Commonly used methods are RAS 117, RAS 137, FM LPDS 1-29 and
ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of
FM LPDS 1-29 for Zone 2/3 enhancements.
5.8
For assemblies with all components fully bonded in place, the maximum design pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
5.9
For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or
ANSI/SPRI FX-1.
5.10
For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ASTM E907, FM LPDS 1-52, TAS 124 or ANSI/SPRI IA-1 shall be conducted on mock-ups of the proposed
new roof assembly.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.09.04-R21
FL3443-R18
Revision 21: 02/12/2016
Page 4 of 5
6.
7.
5.11
For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system
shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124.
5.12
Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind
speed shall be determined from FBC Figure 1609.
5.13
All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule
61G20-3.
INSTALLATION:
®
6.1
EverGuard PVC Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
6.2
System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
6.3
For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed
running perpendicular to steel deck flutes.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8.
MANUFACTURING PLANTS:
Contact named QA entity for details on manufacturing facilities covered for QA under F.A.C. Rule 61G20-3
requirements.
9.
QUALITY ASSURANCE ENTITY:
UL, LLC. – QUA9625; (314) 578-3406; k.chancellor@ul.com
- THE 39-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC.
Certificate of Authorization #9503
Evaluation Report 01506.09.04-R21
FL3443-R18
Revision 21: 02/12/2016
Page 5 of 5
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
1A
1B
1C
1D
2A-1
2A-2
2B-1A
2B-1B
2B-2
2C
3A
3B
4A
4B
4C
5A
6A
6B
6C
6D
7A
7B
Deck
Wood
Wood
Wood
Wood
Steel or Conc.
Steel or Conc.
Steel or Conc.
Steel or Conc.
Steel or Conc.
Steel
Concrete
Concrete
LWIC
LWIC
LWIC
CWF
Gypsum
Gypsum
Gypsum
Gypsum
Various
Concrete
Application
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New, Reroof (Tear-Off) or Recover
New or Reroof (Tear-Off)
New or Reroof (Tear-Off)
New or Reroof (Tear-Off)
New or Reroof (Tear Off)
New or Reroof (Tear-Off)
New or Reroof (Tear-Off)
Reroof (Tear-Off)
Reroof (Tear-Off)
Reroof (Tear-Off)
Reroof (Tear-Off)
Recover
Recover
Type
B-1
C-1
C-2
D-1
B-1
B-2
C-1
C-1A
C-2
D-1
A-1
F
A-1
E
F
A-1
A-1
B-1
C-1
F
A-1
F
Description
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
Mechanically Attached Insulation, Bonded Roof Cover
Plate-Bonded Roof Cover
Mechanically Attached Roof Cover
Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
Mechanically Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover
Mechanically Attached Insulation, Bonded Roof Cover
Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover
Mechanically Attached Insulation, Plate-Bonded Roof Cover
Mechanically Attached Roof Cover
Bonded Insulation, Bonded Roof Cover
Non-Insulated, Bonded Roof Cover
Bonded Insulation, Bonded Roof Cover
Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover
Non-Insulated, Bonded Roof Cover
Bonded Insulation, Bonded Roof Cover
Bonded Insulation, Bonded Roof Cover
Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
Mechanically Attached Insulation, Bonded Roof Cover
Non-Insulated, Bonded Roof Cover
Bonded Insulation, Bonded Roof Cover
Non-Insulated, Bonded Roof Cover
Page
4
4
5
5
6-12
13
14-16
17-18
19
20
21-26
26
27
27
28-29
30
31
31-33
34
34
35-38
39
The following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval documentation.
2.
Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
 Wood Deck:
Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate
(insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. ¾-inch plywood penetration or minimum 1-inch wood plank embedment.
 Steel Deck:
Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec
AccuTrac Recessed Plate (insulation only). Minimum ¾-inch steel penetration, engage the top flute of the steel deck.
 Concrete Deck:
Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation
only) or Drill-Tec Heavy Duty ASAP 3S. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 1 of 39
3.
Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
A separator is required when using polystyrene insulation with smooth-backed EverGuard® PVC membranes (EverGuard® PVC XK, EverGuard® PVC Smooth and EverGuard® PVC-50; 60; 80). Refer to GAF published
installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuard® roofing systems:
Insulation:
 Expaned polystyrene (EPS) meeting or exceeding ASTM C578,
Type II, nominal 1.5 lb/ft2 density and minimum 15 psi
compressive strength.
 Expanded polystyrene (EPS) with plastic facer meeting or
exceeding ASTM C578, Type II, nominal 1.5 lb/ft2 density and
minimum 15 psi compressive strength.
High Traffic Applications:
 Extruded polystyrene (XPS) meeting or exceeding ASTM C578,
Type IV, minimum 1-inch thick and minimum 25 psi compressive
strength.
 Expanded polystyrene (EPS) with plastic facer meeting or
exceeding ASTM C578, Type IX, minimum 1-inch thick and
minimum 25 psi compressive strength.
Recover Applications:
 XPS Fan-Fold Recover Board with plastic facer meeting or
exceeding ASTM C578, Type IV, 3/8-inch thick and minimum 25
psi compressive strength.
 EPS Recover Board meeting or exceeding ASTM C578, Type IV,
1/2-inch thick and minimum 25 psi compressive strength.
 EPS Recover Board with plastic facer meeting or exceeding ASTM
C578, Type II, 1/2-inch thick and minimum 15 psi compressive
strength.
TOPCOAT® FireOut™ Fire Barrier Coating, VersaShield® Fire-Resistant Roof Deck Protection or VersaShield® Solo™ Fire-Resistant Slip Sheet, installed in accordance with GAF published installation instructions and fire
resistance certification listings, may be used as a non-load-bearing, fire-barrier / slip-sheet component within any system outlined herein.
4.
Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete (LWIC) may be substituted for or installed below the rigid insulation board for System Type C-1 (mechanically attached insulation, bonded roof
cover), System Type C-2 (plate-bonded roof cover) or System Type D-1 (mechanically attached membrane), whereby the insulation or membrane fasteners are installed through the LWIC to engage the structural steel
or concrete deck. For Type C-1, the top insulation layer shall be that specified in the applicable Table. For Type C-2 or D-1, if the LWIC is installed below, the rigid insulation board may consist of min. 0.5-inch
EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation, EnergyGuard RH HD Polyiso Insulation or Structodek High Density
Fiberboard Roof Insulation or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, SECUROCK Glass-Mat Roof Board or Dens Deck. The structural deck shall be of equal or greater type, thickness and strength to the
steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper
codified and/or FBC Approval documentation. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-relatated issues, such as deck venting or moisture levels within the LWIC and
the potential effect on overlying components.
5.
Preliminary insulation attachment for System Type D-1 = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board.
6.
Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions.
 Hot Asphalt (HA):
Full mopping, 25-30 lbs/square.
 OlyBond 500 (OB500):
Continuous ¾ to 1-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond
500 is referenced.
 GAF LRF Adhesive M (LRF-M):
Continuous 1-inch wide ribbons, 12-inch o.c
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c.
 Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered.
 Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7.
Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table.
 Hot Asphalt (HA):
MDP =
-240.0 psf (Min. 0.5-inch thick)
 OlyBond 500 (OB500):
MDP =
-292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra)
 OlyBond 500 (OB500):
MDP =
-315.0 psf (Min. 0.5-inch thick EnergyGuard RN or RH)
 OlyBond 500 (OB500):
MDP =
-487.5 psf (Min. 0.5-inch thick EnergyGuard RA)
 GAF 2-Part Roofing Adhesive (GAF 2-Part):
MDP =
-117.5 psf (Min. 1.0-inch thick)
8.
Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 2 of 39
9.
For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, RAS 137, FM LPDS 1-29
and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52,
TAS 124 or ANSI/SPRI IA-1.
13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes.
14. For Recover Applications using System Type C-2 or any System Type D, the insulation is optional. Alternatively, a separator board may be installed prior to roof cover installation when using System Type C-2 or any
System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The existing roof system shall be suitable for a recover application. The separator component shall
be documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover in Recover applications.
 Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, or min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof
Board.
 Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd2) or EverGuard Polymat Cushioning Layer (6 oz/yd2).
15. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC
Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum topcoat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
16. For adhesive-applied membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows:
Membrane
EverGuard PVC-50, -60 or -80
EverGuard PVC Smooth or PVC XK
EverGuard PVC XK Fleeceback
EverGuard PVC XK Fleeceback
Adhesive
EverGuard #2331 Bonding Adhesive (#2331)
EverGuard #2331 Bonding Adhesive (#2331)
Hot asphalt
EverGuard WB181 Bonding Adhesive (WB181)
Method
Contact (both sides)
Contact (both sides)
Wet lay (substrate)
Wet lay (substrate)
EverGuard PVC XK Fleeceback
GAF LRF Adhesive M (LRF-M) or LRF Adhesive O
(LRF-O)
Wet lay (substrate)
EverGuard PVC XK Fleeceback
GAF 2-Part Roofing Adhesive (GAF 2-Part)
Wet lay (substrate)
Rate
1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane)
1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane)
25 lbs/square
0.83 to 1.0 gal/square
1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are
located directly over the adhesive ribbons used to secure the insulation when the cover
is bonded to insulation less than 1.5-inch thick.
“Spatter pattern” at 3.75 lbs/sq.
17. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 3 of 39
TABLE 1A: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Fasten
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
W-1.
Min. 15/32-inch plywood or
wood plank at max. 2 ft
spans
Min 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
See Note 2 (#14
Fastener only)
1 per 2 ft2
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
LRF-M, OB500 or
GAF 2-Part
EverGuard PVC Smooth or PVC
XK / #2331
-52.5
See Note 2 (#14
Fastener only)
1 per 2 ft2
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
LRF-M, OB500 or
GAF 2-Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-52.5
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
W-2.
Min. 15/32-inch plywood or
wood plank at max. 2 ft
spans
Min 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard RH
TABLE 1B: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
W-3.
Deck (See Note 1)
Min. 23/32-inch plywood; 24inch spans
Base Insulation Layer
One or more layers, min. 1.5inch ASTM C1289 insulation
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Top Insulation Layer
Type
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
Fasteners
See Note 2
Attach
1 per 2 ft2
Roof Cover / Adhesive
EverGuard PVC-50, -60 or -80 / #2331
MDP
(psf)
-45.0*
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 4 of 39
TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Attachment
Insulation Layer
Fasteners
W-4.
Min. 15/32-inch
plywood; 24-inch span
One or more layers, any
combination, (Tread Safe
= min. 2-inch)
W-5.
Min. 15/32-inch plywood
over nominal No. 2 wood
trusses spaced max. 24inch o.c.
(Optional) One or more
layers, any combination,
preliminarily attached
(Tread Safe = min. 2-inch
thick insulation)
Roof Cover
MDP
(psf)
1 per 2.67 ft² (12 parts per 4 x 8 ft board)
Fasteners are 6-, 24- and 42-inches from the
board’s long edge and 12-, 36-, 60- and 84inches from the board’s short edge.
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
-52.5
18-inch o.c. along wood supports, 24-inch o.c.
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
-82.5
Density
Drill-Tec #14 Fastener and Drill-Tec
RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe
Plates
Drill-Tec #14 (min. 1-inch
embedment) and Drill-Tec RhinoBond
PVC XHD Plates or Drill-Tec
RhinoBond PVC XHD Tread Safe Plates
through to wood supports
TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER
System
No.
Deck (See Note 1)
Insulation
Type
Roof Cover
Attach
Membrane
Fasteners
Attachment
MDP
(psf)
W-6.
Min. 15/32-inch
plywood; 24-inch span
One or more layers, any
combination, min. 0.5-inch
Prelim.
Attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2 in. Double
Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD
Plates or Drill-Tec Eyehook AccuSeam Plate
9-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld.
-30.0
W-7.
Min. 23/32-inch
plywood; 24-inch spans
(Optional) One or more
layers, any combination
Prelim.
attach
EverGuard PVC50, -60 or -80
Trufast EHD with Trufast 2.4-inch Barbed Seam
Plates
12-inch o.c. within 5.5-inch wide laps spaced
75.5-inch o.c. and sealed with a 1.5-inch heat
weld.
-37.5
W-8.
Min. 15/32-inch
plywood; 24-inch span
One or more layers, any
combination, min. 0.5-inch
Prelim.
Attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2 in. Double
Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD
Plates or Drill-Tec Eyehook AccuSeam Plate
6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld.
-37.5
W-9.
Min. 19/32-inch
plywood; 24-inch span
One or more layers, any
combination, min. 0.5-inch
Prelim.
attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2 in. Double
Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD
Plates or Drill-Tec Eyehook AccuSeam Plate
8-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
W-10.
Min. 19/32-inch
plywood; 24-inch span
One or more layers, any
combination, min. 0.5-inch
Prelim.
attach
EverGuard PVC XK
or PVC Smooth
Drill-Tec #14 Fastener with Drill-Tec 2 in. Double
Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD
Plates or Drill-Tec Eyehook AccuSeam Plate
6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 5 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-1.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
See Note 2
1 per 2
ft2
Additional layers of base insulation
Hot
asphalt
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-2.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2.0-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
See Note 2
1 per 4
ft2
Additional layers of base insulation
Hot
asphalt
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-3.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
See Note 2
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-4.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-5.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-EnergyGuard RH
See Note 2
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-6.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-7.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-8.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-9.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
See Note 2
1 per 2
ft2
Min. 0.25-inch thick SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-10.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-11.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min 2-inch EnergyGuard RA,
EnergyGuard RN or EnergyGuard
RH
See Note 2
1 per 4
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-12.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 6 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
S-13.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-14.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 0.5-inch Dens Deck
See Note 2
1 per 2
ft2
One or more layers, min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard RH
OB500
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-15.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-16.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-EnergyGuard RH
See Note 2
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-17.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-18.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-19.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-20.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-21.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-22.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-23.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
LRF-M,
OB500 or
GAF 2Part
EverGuard PVC Smooth or PVC XK
/ #2331
See Note 2
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-52.5
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-24.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
-37.5*
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 7 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
S-25.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-26.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-27.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Additional layers, min. 1.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-28.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
See Note 2
1 per 2
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-29.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-30.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-31.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-32.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-37.5*
S-33.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-EnergyGuard RH
See Note 2
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-37.5*
S-34.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-35.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-36.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Additional layers, min. 1.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 8 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
S-37.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-38.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-39.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-40.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Additional layers, min. 1.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-41.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Additional layers, min. 1.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
WB181
-45.0*
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
S-42.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-43.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-44.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-45.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 3.2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-30.0*
S-46.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-47.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-48.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 9 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
S-49.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-50.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
Ultra
See Note 2
1 per 2
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-51.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-52.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
See Note 2
1 per 4
ft2
Optional additional layers, min. 1.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-53.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-54.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-55.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-56.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-57.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 3.2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-30.0*
S-58.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-59.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-60.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 10 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
S-61.
Deck
(See Note 1)
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Base Insulation Layer
Type
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
Top Insulation Layer
Type
Attach
Roof Cover / Adhesive
MDP (psf)
Fasten
Attach
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
S-62.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 3.2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-30.0*
S-63.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-64.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-65.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-66.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-67.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-52.5
S-68.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 3.2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-30.0*
S-69.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-70.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-71.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-72.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 11 of 39
TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Roof Cover / Adhesive
MDP (psf)
Fasten
Attach
Type
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-52.5
S-73.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
See Note 2
1 per 2
ft2
S-74.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 3.2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-30.0*
S-75.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2
ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-76.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Additional layers, min. 0.5-inch base insulation
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-77.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 1.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard
RH, EnergyGuard RN
See Note 2
1 per 2
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-78.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH,
EnergyGuard RN
See Note 2
1 per 2.9
ft2
Optional additional layers, min. 0.5-inch base
insulation followed by min. 0.25-inch Dens Deck
Prime or SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-79.
Min. 22 ga., Type B,
Grade 33 steel or
struct conc.
Min 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard RH
See Note 2
1 per 2
ft2
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 12 of 39
TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF)
SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Thermal Barrier
Type
Fasten
Temp Roof
Attach
Type
Insulation Layer(s)
Attach
Type
Attach
Roof Cover /
Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-80.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
S-81.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
S-82.
Min. 22 ga.,
Grade 33 steel
or struct conc.
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
S-83.
Min. 22 ga.,
Grade 33 steel
or struct conc.
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
OB500
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN followed by Min.
0.25-inch Dens Deck Prime
OB500
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN followed by Min.
0.25-inch SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RH
followed by Min. 0.5-inch
EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard
HD Plus Polyiso Insulation
OB500
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH
OB500
EverGuard PVC XK
Fleeceback /
WB181
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard
RH followed by min. 0.25-inch
Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback /
WB181
-45.0*
1 per 2.7
ft2
UnderRoof 2 PolyesterSurfaced Leak Barrier or
UnderRoof HT High
Temperature Leak Barrier
Selfadhered
Min. 1.5-inch EnergyGuard RH
followed by Min. 0.5-inch
EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD
Polyiso Insulation, EnergyGuard
HD Plus Polyiso Insulation
OB500
EverGuard PVC XK
Fleeceback /
WB181
-45.0*
See Note 2
Min. 22 ga.,
Grade 33 steel
or struct conc.
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
See Note 2
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
See Note 2
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
See Note 2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
EVERGUARD PVC XK FLEECEBACK APPLICATIONS:
S-84.
Min. 22 ga.,
Grade 33 steel
or struct conc.
S-85.
Min. 22 ga.,
Grade 33 steel
or struct conc.
S-86.
Min. 22 ga.,
Grade 33 steel
or struct conc.
See Note 2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
See Note 2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
See Note 2
Min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
(Drill-Tec 3 in. Ribbed
Galvalume Plate (Flat)
may be used)
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 13 of 39
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Roof Cover / Adhesive
MDP (psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-87.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH
See Note 2
1 per 3.2
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-30.0*
S-88.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 4 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-30.0*
S-89.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH
See Note 2
1 per 2.67
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-90.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2.67
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-37.5*
S-91.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN or
EnergyGuard RH
See Note 2
1 per 2 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-92.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-93.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard RA, EnergyGuard RN or
EnergyGuard RH
See Note 2
1 per 4 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-94.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-95.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-96.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.5-inch Dens Deck Prime
See Note 2
1 per 3.2
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-97.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.625-inch Dens Deck Prime
See Note 2
1 per 4 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-98.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
See Note 2
1 per 2 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-99.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
One or more layers, any
combination, min. 1.5-inch
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
See Note 2
1 per 2 ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-45.0*
S-100.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation
See Note 2
1 per 1.78
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-60.0
S-101.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard RH
See Note 2
1 per 1.78
ft2
EverGuard PVC Smooth or PVC XK
/ #2331
-67.5
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 4 ft2
EverGuard PVC XK Fleeceback /
WB181
-30.0*
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-102.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 14 of 39
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck (See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Roof Cover / Adhesive
MDP (psf)
S-103.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2.67
ft2
EverGuard PVC XK Fleeceback /
WB181
-37.5*
S-104.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-105.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback /
WB181
-45.0*
S-106.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
One or more layers, any
combination, min. 1.5-inch
Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD
Plus Polyiso Insulation
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
WB181
-45.0*
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
S-107.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 4 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-30.0*
S-108.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 4 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-37.5*
S-109.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2.67
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-37.5*
S-110.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-111.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-112.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or ACFoam IV
See Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-60.0
S-113.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination, min. 1.5-inch
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-M, 12-inch o.c.
-37.5*
S-114.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination, min. 1.5-inch
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-O, 12-inch o.c.
-45.0*
S-115.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination, min. 1.5-inch
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 12-inch o.c.
-45.0*
S-116.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-117.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
S-118.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-60.0
S-119.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 15 of 39
TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
S-120.
Deck (See Note 1)
Min. 22 ga., Type B, Grade
33 steel or struct conc.
Base Insulation Layer
(Optional) One or more layers,
any combination
Top Insulation Layer
Type
Fasten
Attach
Roof Cover / Adhesive
MDP (psf)
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board
See Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback /
LRF-M or LRF-O, 4-inch o.c.
-67.5
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
S-121.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
See Note 2
1 per 4 ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-30.0*
S-122.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 4 ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-37.5*
S-123.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2.67
ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-37.5*
S-124.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-125.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 2-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 2.9
ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-126.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 1.5-inch EnergyGuard RH, EnergyGuard RN
See Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-60.0
S-127.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.25-inch Dens Deck Prime
See Note 2
1 per 2 ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-45.0*
S-128.
Min. 22 ga., Type B, Grade
33 steel or struct conc.
(Optional) One or more layers,
any combination
Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board
See Note 2
1 per 1.33
ft2
EverGuard PVC XK Fleeceback /
GAF 2-Part, spatter
-67.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 16 of 39
TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Top Insulation Layer
Type
Fasten
Attach
Roof Cover /
Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
S-129.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck or min. 0.5-inch SECUROCK Glass-Mat
Roof Board, loose-laid, followed by UnderRoof 2 PolyesterSurfaced Leak Barrier, UnderRoof HT High Temperature Leak
Barrier or WeatherWatch XT Mat Surfaced Leak Barrier, selfadhered, followed by min. 1.5-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid
S-130.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH
See
Note 2
1 per 2 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
S-131.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 2-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH
See
Note 2
1 per 4 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
S-132.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH, loose laid, followed by min. 0.25-inch
Dens Deck Prime
See
Note 2
1 per 2 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
S-133.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH, loose laid, followed by min. 0.5-inch
Dens Deck Prime
See
Note 2
1 per 3.2
ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
S-134.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH, loose laid, followed by min. 0.625-inch
Dens Deck Prime
See
Note 2
1 per 4 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
S-135.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard RH, loose laid, followed by min. 0.25-inch
SECUROCK Gypsum-Fiber Roof Board
See
Note 2
1 per 2 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 0.625-inch Dens Deck Prime
See
Note 2
1 per 4 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 17 of 39
TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
No.
S-136.
Deck
(See Note 1)
Base Insulation Layer
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Top Insulation Layer
Roof Cover /
Adhesive
MDP
(psf)
1 per 2 ft2
EverGuard PVC
Smooth or PVC XK
/ #2331
-45.0*
1 per 2 ft2
EverGuard PVC XK
Fleeceback /
WB181
-45.0*
Type
Fasten
Attach
Min. 1.5-inch EnergyGuard RH, loose laid, followed by
min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
See
Note 2
Min. 1.5-inch EnergyGuard RH, loose laid, followed by
min. 0.5-inch EnergyGuard RH HD Polyiso Insulation,
EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus
Polyiso Insulation
See
Note 2
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
S-137.
Min. 22 ga., Type
B, Grade 33 steel
or struct conc.
Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK
Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch
XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced
Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 18 of 39
TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Insulation Layer
S-138.
Min. 22 ga., type
B, Grade 33 steel
One or more layers, any
combination, (Tread Safe =
min. 2-inch)
S-139.
Min. 22 ga., type
B, Grade 33 steel
One or more layers, any
combination
Attachment
Fasteners
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates or
Drill-Tec RhinoBond PVC XHD
Tread Safe Plates
Drill-Tec SXHD and Drill-Tec
RhinoBond PVC XHD Plates
Density
1 per 5.3 ft² (6 parts per 4 x 8 ft board)
Fasteners located in each of the four corners of
the board and at mid-span of the 96-inch length.
Fasteners are 6-inches from the board’s long
edges and 12-inches and 48-inches from the
board’s short edges.
24 x 36 inch grid
Roof Cover
MDP (psf)
EverGuard PVC-50, -60 or -90 bonded to Drill-Tec
RhinoBond PVC XHD Plates or Drill-Tec
RhinoBond PVC XHD Tread Safe Plates with
RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-45.0*
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
with RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-45.0
1 per 4 ft² (8 parts per 4 x 8 ft board)
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates or
Drill-Tec RhinoBond PVC XHD
Tread Safe Plates
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
24 x 24 inch grid
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
with RhinoBond Portable Bonding Tool, per
manufacturer’s published instructions.
-60.0
1 per 2.67 ft² (12 parts per 4 x 8 ft board)
Fasteners are 6-, 24- and 42-inches from the
board’s long edge and 12-, 36-, 60- and 84-inches
from the board’s short edge.
EverGuard PVC XK or EverGuard PVC Smooth
bonded to Drill-Tec RhinoBond PVC XHD Plates
or Drill-Tec RhinoBond PVC XHD Tread Safe
Plates with RhinoBond Portable Bonding Tool,
per manufacturer’s published instructions.
-67.5
S-140.
Min. 20 ga., type
B, Grade 33 steel
One or more layers, any
combination, (Tread Safe =
min. 2-inch)
S-141.
Min. 22 ga., type
B, Grade 33 steel
One or more layers, any
combination
Drill-Tec SXHD and Drill-Tec
RhinoBond PVC XHD Plates
S-142.
Min. 22 ga., type
B, Grade 33 steel
One or more layers, any
combination, (Tread Safe =
min. 2-inch)
Drill-Tec XHD and Drill-Tec
RhinoBond PVC XHD Plates or
Drill-Tec RhinoBond PVC XHD
Tread Safe Plates
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
-52.5
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 19 of 39
TABLE 2C: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER
SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER
System
No.
Insulation
Deck (See Note 1)
Type
Roof Cover
Attach
Membrane
Fasteners
Attachment
MDP (psf)
EVERGUARD PVC-50, -60 OR -80:
S-143.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
18-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld.
-30.0
S-144.
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
12-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld.
-37.5
S-145.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
12-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
S-146.
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2-inch
Barbed Plates
6-inch o.c. within 6-inch wide laps spaced 75-inch
o.c. and sealed with a 1.5-inch heat weld.
-52.5
S-147.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC-50, -60
or -80
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
6-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld.
-75.0
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK:
S-148.
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
6-inch o.c. within minimum 6-inch wide laps
spaced maximum 114-inch o.c. and sealed with a
1.5-inch heat weld
-30.0
S-149.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
6-inch o.c. within minimum 5.5-inch wide laps
spaced maximum 114.5-inch o.c. and sealed with
a 2-inch heat weld
-37.5
S-150.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec SXHD #21 with Drill-Tec 2
¾ in. Barbed SXHD Plates
12-inch o.c. within minimum 6-inch wide laps
spaced maximum 114-inch o.c. and sealed with a
2-inch heat weld
-37.5
S-151.
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec #14 Fasteners with DrillTec 2 in. Barbed Plates
6-inch o.c. within 5-inch wide laps spaced 55-inch
o.c. and sealed with a 2-inch heat weld.
-45.0
S-152.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
6-inch o.c. within minimum 5.5-inch wide laps
spaced maximum 75.5-inch o.c. and sealed with a
2-inch heat weld
-45.0
S-153.
Min. 22 ga., type B,
Grade 80 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec SXHD #21 with Drill-Tec 2
¾ in. Barbed SXHD Plates
12-inch o.c. within minimum 6-inch wide laps
spaced maximum 75-inch o.c. and sealed with a
2-inch heat weld
-45.0
S-154.
Min. 22 ga., type B,
Grade 33 steel
One or more layers, any
combination, min. 1.5-inch
Prelim. attach
EverGuard PVC XK or
EverGuard PVC Smooth
Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates
6-inch o.c. within 6-inch wide laps spaced 114inch o.c. and sealed with a 1.5-inch heat weld.
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 20 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
Deck
Vapor Barrier
No.
(See Note 1)
EVERGUARD PVC-50, -60 or -80 APPLICATIONS:
(Optional) See Note A
C-1.
Struct conc.
below
Base Insulation Layer
Type
Min. 1-inch EnergyGuard RA
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard Ultra,
C-2.
Struct conc.
ACFoam III, Min. 2-inch Styrofoam
Deckmate Plus FA or Min. 1-inch
Foamular 250
(Optional) See Note A
Min. 1.5-inch EnergyGuard RA,
C-3.
Struct conc.
below
EnergyGuard RN, ACFoam III
EVERGUARD PVC SMOOTH OR PVC XK / EVERGUARD #2331 BONDING ADHESIVE:
(Optional) See Note A
Min. 0.5-inch EnergyGuard Polyiso
C-4.
Struct conc.
below
Insulation, EnergyGuard Ultra
(Optional) See Note A
Min. 1.5-inch EnergyGuard RA,
C-5.
Struct conc.
below
EnergyGuard RH or EnergyGuard RN
D41 or Matrix™ 307
Premium Asphalt Primer
C-6.
Struct conc.
Min. 1.5-inch EnergyGuard RH
& UnderRoof HT High
Temperature Leak Barrier
D41 or Matrix™ 307
Premium Asphalt Primer
C-7.
Struct conc.
Min. 1.5-inch EnergyGuard RH
& UnderRoof 2 PolyesterSurfaced Leak Barrier
(Optional) See Note A
below
Top Insulation Layer
Type
Attach
Attach
None
N/A
EverGuard PVC-50, -60 or -80
/ #2331
-325.0
OB500
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC-50, -60 or -80
/ #2331
-240.0
GAF 2Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC-50, -60 or -80
/ #2331
-240.0
OB500
(Optional) Additional layers of base insulation
OB500
OB500
(Optional) Additional layer of base insulation
OB500
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-37.5
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-97.5
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-97.5
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
Min. 1.5-inch EnergyGuard RH
(Optional) See Note A
below
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
C-12.
Struct conc.
(Optional) See Note A
below
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
OB500
C-13.
Struct conc.
None
Min. 1-inch EnergyGuard RH
LRF-M
(Optional) Additional layer of base insulation
LRF-M
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
(Optional) Additional layers of base insulation
LRF-M
Struct conc.
C-9.
Struct conc.
C-10.
Struct conc.
C-11.
C-14.
Struct conc.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
MDP
(psf)
OB500
(Optional) See Note A
below
C-8.
Roof Cover / Adhesive
OB500
OB500
OB500
Min. 0.25-inch Dens Deck Prime
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
OB500
OB500
OB500
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
EverGuard PVC Smooth or
PVC XK / #2331
-232.5
-247.5
-232.5
-247.5
-202.5
-202.5
-162.5
-232.5
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 21 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Vapor Barrier
Base Insulation Layer
Type
Attach
C-15.
Struct conc.
None
Min. 1.5-inch EnergyGuard RH
LRF-M
C-16.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
C-17.
Struct conc.
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
C-18.
Struct conc.
(Optional) See Note A
below
C-19.
Struct conc.
(Optional) See Note A
below
C-20.
Struct conc.
(Optional) See Note A
below
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min.
1-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min.
1-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min.
1-inch EnergyGuard RA, EnergyGuard
RH, EnergyGuard RN
EVERGUARD PVC XK FLEECEBACK IN HOT ASPHALT:
Struct conc.
C-21.
None
Min. 1-inch EnergyGuard RH
(primed)
EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE:
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
Insulation, EnergyGuard Ultra or min.
C-22.
Struct conc.
below
1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
D41 or Matrix™ 307
Premium Asphalt Primer
C-23.
Struct conc.
Min. 1.5-inch EnergyGuard RH
& UnderRoof HT High
Temperature Leak Barrier
D41 or Matrix™ 307
Premium Asphalt Primer
C-24.
Struct conc.
Min. 1.5-inch EnergyGuard RH
& UnderRoof 2 PolyesterSurfaced Leak Barrier
C-25.
Struct conc.
(Optional) See Note A
below
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Min. 1.5-inch EnergyGuard RH
Top Insulation Layer
Type
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
Roof Cover / Adhesive
MDP
(psf)
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-97.5
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-232.5
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-202.5
Attach
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC Smooth or
PVC XK / #2331
-232.5
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
GAF 2Part
EverGuard PVC Smooth or
PVC XK / #2331
-232.5
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
GAF 2Part
EverGuard PVC Smooth or
PVC XK / #2331
-202.5
HA
(Optional) Additional layers of base insulation
HA
EverGuard PVC XK Fleeceback
/ Hot asphalt
-490.0
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-90.0
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-37.5
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-97.5
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK Fleeceback
/ WB181
-97.5
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 22 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Vapor Barrier
C-26.
Struct conc.
(Optional) See Note A
below
C-27.
Struct conc.
None
Base Insulation Layer
Type
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min.
1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Attach
MDP
(psf)
OB500
EverGuard PVC XK Fleeceback
/ WB181
-90.0
LRF-M
(Optional) Additional layers of base insulation
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-90.0
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-90.0
LRF-M
EverGuard PVC XK Fleeceback
/ WB181
-97.5
None
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
C-29.
Struct conc.
None
Min. 1.5-inch EnergyGuard RH
LRF-M
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Roof Cover / Adhesive
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Struct conc.
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min.
C-30.
Struct conc.
1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
Insulation, EnergyGuard Ultra or min.
C-31.
Struct conc.
below
1.5-inch EnergyGuard RA,
EnergyGuard RH or EnergyGuard RN
EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O:
(Optional) See Note A
Min. 1-inch EnergyGuard RA,
C-32.
Struct conc.
below
EnergyGuard RH, EnergyGuard RN
(Optional) See Note A
Min. 0.5-inch EnergyGuard Polyiso
C-33.
Struct conc.
below
Insulation, EnergyGuard Ultra
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
C-34.
Struct conc.
Insulation, EnergyGuard Ultra,
below
EnergyGuard RA, EnergyGuard RH
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
C-35.
Struct conc.
Insulation, EnergyGuard Ultra,
below
EnergyGuard RA, EnergyGuard RH
(Optional) See Note A
(Optional) Min. 1-inch EnergyGuard
C-36.
Struct conc.
below
RA, EnergyGuard RH, EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
Insulation, EnergyGuard Ultra,
C-37.
Struct conc.
below
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
C-38.
Struct conc.
Insulation, EnergyGuard Ultra,
below
EnergyGuard RH, EnergyGuard RN
Attach
OB500
C-28.
(Optional) See Note A
below
Top Insulation Layer
Type
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ WB181
-90.0
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ WB181
-90.0
OB500
(Optional) Additional layers of base insulation
OB500
OB500
(Optional) Additional layers of base insulation
OB500
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK Fleeceback
/ LRF-M, 12-inch o.c.
-37.5
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
-45.0
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M, 6-inch o.c.
-45.0
OB500
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 6-inch o.c.
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0
-60.0
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 23 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Vapor Barrier
D41 or Matrix™ 307
Premium Asphalt Primer
& Ruberoid HW Smooth
or Ruberoid HW 25
Smooth, torch applied
(Optional) See Note A
below
C-39.
Struct conc.
C-40.
Struct conc.
C-41.
Struct conc.
None
C-42.
Struct conc.
None
C-43.
Struct conc.
None
C-44.
Struct conc.
None
C-45.
Struct conc.
None
C-46.
Struct conc.
None
C-47.
Struct conc.
D41 or Matrix™ 307
Premium Asphalt Primer
& Ruberoid HW Smooth
or Ruberoid HW 25
Smooth, torch applied
C-48.
Struct conc.
None
C-49.
Struct conc.
(Optional) See Note A
below
C-50.
Struct conc.
(Optional) See Note A
below
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Base Insulation Layer
Type
Top Insulation Layer
Type
Attach
Attach
Roof Cover / Adhesive
MDP
(psf)
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
None
N/A
Min. 1-inch EnergyGuard RH
LRF-M
(Optional) Additional layers of base insulation
LRF-M
LRF-M
(Optional) Additional layers of base insulation
LRF-M
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M, 12-inch o.c.
-37.5
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
-45.0
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
LRF-M
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
LRF-M
None
N/A
GAF 2Part
(Optional) Additional layers of base insulation
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-O, 12-inch o.c.
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
EverGuard PVC XK Fleeceback
/ LRF-M, 6-inch o.c.
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-195.0
-45.0
-60.0
-195.0
-60.0
-45.0
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 24 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Vapor Barrier
C-51.
Struct conc.
(Optional) See Note A
below
C-52.
Struct conc.
(Optional) See Note A
below
Base Insulation Layer
Type
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
D41 or Matrix™ 307
Premium Asphalt Primer
Min. 0.5-inch EnergyGuard Polyiso
C-53.
Struct conc.
& Ruberoid HW Smooth
Insulation, EnergyGuard Ultra,
or Ruberoid HW 25
EnergyGuard RH, EnergyGuard RN
Smooth, torch applied
(Optional) See Note A
Min. 0.25-inch Dens Deck Prime or
C-54.
Struct conc.
below
SECUROCK Gypsum-Fiber Roof Board
EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE:
(Optional) See Note A
Min. 0.5-inch EnergyGuard Polyiso
C-55.
Struct conc.
below
Insulation, EnergyGuard Ultra
Min. 0.5-inch EnergyGuard Polyiso
(Optional) See Note A
C-56.
Struct conc.
Insulation, EnergyGuard Ultra,
below
EnergyGuard RH, EnergyGuard RN
D41 or Matrix™ 307
Premium Asphalt Primer
Min. 0.5-inch EnergyGuard Polyiso
C-57.
Struct conc.
& Ruberoid HW Smooth
Insulation, EnergyGuard Ultra,
or Ruberoid HW 25
EnergyGuard RH, EnergyGuard RN
Smooth, torch applied
(Optional) See Note A
Min. 0.25-inch Dens Deck Prime or
C-58.
Struct conc.
below
SECUROCK Gypsum-Fiber Roof Board
Min. 0.5-inch EnergyGuard Polyiso
C-59.
Struct conc.
None
Insulation, EnergyGuard Ultra
Min. 0.5-inch EnergyGuard Polyiso
C-60.
Struct conc.
None
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
D41 or Matrix™ 307
Premium Asphalt Primer
Min. 0.5-inch EnergyGuard Polyiso
C-61.
Struct conc.
& Ruberoid HW Smooth
Insulation, EnergyGuard Ultra,
or Ruberoid HW 25
EnergyGuard RH, EnergyGuard RN
Smooth, torch applied
Min. 0.25-inch Dens Deck Prime or
C-62.
Struct conc.
None
SECUROCK Gypsum-Fiber Roof Board
(Optional) See Note A
Min. 0.5-inch EnergyGuard Polyiso
C-63.
Struct conc.
below
Insulation, EnergyGuard Ultra
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Top Insulation Layer
Type
Attach
Attach
Roof Cover / Adhesive
MDP
(psf)
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 12-inch o.c.
-45.0
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
GAF 2Part
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-180.0
GAF 2Part
None
N/A
EverGuard PVC XK Fleeceback
/ LRF-M or LRF-O, 4-inch o.c.
-195.0
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-60.0
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0
OB500
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0
OB500
None
N/A
LRF-M
(Optional) Additional layers of base insulation
LRF-M
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0
LRF-M
(Optional) Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0
LRF-M
None
N/A
(Optional) Additional layers of base insulation
GAF 2Part
GAF 2Part
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-195.0
-60.0
-195.0
-60.0
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 25 of 39
TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
C-64.
Deck
(See Note 1)
Struct conc.
Vapor Barrier
(Optional) See Note A
below
Base Insulation Layer
Type
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
Attach
GAF 2Part
Top Insulation Layer
Type
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
Attach
GAF 2Part
Roof Cover / Adhesive
MDP
(psf)
EverGuard PVC XK Fleeceback
/ GAF 2-Part, spatter
-180.0
D41 or Matrix™ 307
Premium Asphalt Primer
Min. 0.5-inch EnergyGuard Polyiso
GAF 2(Optional) Min. 0.25-inch Dens Deck Prime or
GAF 2EverGuard PVC XK Fleeceback
C-65.
Struct conc.
& Ruberoid HW Smooth
Insulation, EnergyGuard Ultra,
-180.0
Part
SECUROCK Gypsum-Fiber Roof Board
Part
/ GAF 2-Part, spatter
or Ruberoid HW 25
EnergyGuard RH, EnergyGuard RN
Smooth, torch applied
(Optional) See Note A
Min. 0.25-inch Dens Deck Prime or
GAF 2EverGuard PVC XK Fleeceback
C-66.
Struct conc.
None
N/A
-195.0
below
SECUROCK Gypsum-Fiber Roof Board
Part
/ GAF 2-Part, spatter
A. The following are options for installation of an optional vapor barrier / temporary roof on the concrete deck prior to insulation placement. If vapor barrier / temp roof is installed, concrete deck shall be primed with
Matrix™ 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation
adhesive noted below.
1.
2.
3.
For use with OB500 applied insulation:
One or two plies, asphalt-applied GAF base and/or ply sheet:
Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage:
Ruberoid Torch Smooth, heat welded:
Ruberoid HW 25 Smooth, heat welded:
Ruberoid HW Smooth, heat welded:
UnderRoof HT High Temperature Leak Barrier, self-adhered:
UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered:
MDP -352.5 psf
MDP -202.5 psf
MDP -165.0 psf
MDP -180.0 psf
MDP -232.5 psf
MDP -37.5 psf
MDP -127.5 psf
For use with GAF 2-Part applied insulation:
One or two plies, asphalt-applied GAF base ply and/or ply:
Optional asphalt-applied GAF base ply, ply or base membrane with asphalt-applied GAF SBS cap membrane:
Optional asphalt-applied GAF base ply, ply or base membrane or heat-welded GAF base membrane with heat-welded GAF SBS or APP cap membrane:
Optional self-adhering Liberty base membrane with Liberty cap membrane:
Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded:
For use with GAF LRF-Adhesive M:
Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded:
MDP -262.5 psf
MDP -270.0 psf
MDP -169.0 psf
MDP -250.0 psf
MDP -180.0 psf
MDP -180.0 psf
TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System No.
Roof Deck
Roof Cover / Adhesive
MDP (psf)
C-67.
Struct conc.
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c.
-45.0
C-68.
Struct conc. primed with Matrix™ 307 Premium Asphalt
Primer
EverGuard PVC XK Fleeceback / Hot asphalt at 25 lbs/square
-502.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 26 of 39
TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Deck (See Note 1)
System
No.
Roof
Deck
Base Insulation Layer
LWIC (See Note 15)
Type
Coverboard
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
LWC-1.
Struct.
conc.
Min. 200 psi, min. 2inch thick Elastizell
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard Ultra, ACFoam III, Min. 2-inch
Styrofoam Deckmate Plus FA or Min. 1-inch
Foamular 250
OB500
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC-50, -60 or -80
/ #2331
-225.0
LWC-2.
Struct.
conc.
Min. 200 psi, min. 2inch thick Elastizell
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-180.0
LWC-3.
Struct.
conc.
Min. 200 psi, min. 2inch thick Celcore
Cellular Concrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-222.5
LWC-4.
Struct.
conc.
Min. 200 psi, min. 2inch thick Mearlcrete
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or SECUROCK
Gypsum-Fiber Roof Board
GAF 2-Part
EverGuard PVC-50, -60 or -80
/ #2331
-240.0
TABLE 4B: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
No.
Roof Deck (See Note 1)
Structural Deck
LWIC (See Note 15)
Base Sheet
Roof Cover
Type
Fasteners
Attach
Base
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Drill-Tec Base Sheet
Fastener (1.7 in.), Drill-Tec
Base Sheet Fastener E (1.7
in.), Drill-Tec Locking Impact
Nail or Trufast FM-290
7-inch o.c. at min. 4inch laps and 7-inch o.c.
in two, equally spaced,
staggered center rows
(Optional) One or two plies Ruberoid
20 Smooth, Ruberoid Mop Smooth,
Ruberoid Mop Smooth 1.5 or
Ruberoid Mop Plus Smooth in hot
asphalt or one or two plies Ruberoid
HW 25 Smooth or Ruberoid HW
Smooth, torch-applied
GAFGLAS #75 Base Sheet,
Tri-Ply #75 Base Sheet,
GAFGLAS #80 Ultima Base
Sheet, GAFGLAS Stratavent
Nailable Venting Base
Sheet, Ruberoid 20 Smooth
Drill-Tec Base Sheet
Fastener (1.7 in.), Drill-Tec
Base Sheet Fastener E (1.7
in.), Drill-Tec Locking Impact
Nail or Trufast FM-290
7-inch o.c. at min. 4inch laps and 7-inch o.c.
in two, equally spaced,
staggered center rows
One or two plies Ruberoid 20
Smooth, Ruberoid Mop Smooth,
Ruberoid Mop Smooth 1.5 or
Ruberoid Mop Plus Smooth in hot
asphalt or one or two plies Ruberoid
HW 25 Smooth or Ruberoid HW
Smooth, torch-applied
Cap
MDP
(psf)
HYBRID SYSTEMS:
LWC-5.
LWC-6.
Min. 22 ga., type
B, 40 ksi vented
steel at max. 6 ft
spans
Min. 22 ga., type
B, 40 ksi vented
steel at max. 6 ft
spans
Min. 340 psi, min. 2-inch thick cellular
lightweight insulating concrete. Note: To
qualify the LWC under this assembly, the
selected fastener shall achieve an average
withdrawal of 60 lbf or greater when tested
per TAS105 or ANSI/SPRI FX-1
Min. 340 psi, min. 2-inch thick cellular
lightweight insulating concrete. Note: To
qualify the LWC under this assembly, the
selected fastener shall achieve an average
withdrawal of 60 lbf or greater when tested
per TAS105 or ANSI/SPRI FX-1
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
EverGuard
PVC XK
Fleeceback in
-52.5
hot apshalt
EverGuard
PVC XK
Fleeceback in
GAF 2-Part,
spatterapplied
-52.5
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 27 of 39
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
Roof Deck (See Note 1)
System
No.
Roof Cover
Min. Compressive
Strength (psi)
Min.
Thick (in)
Membrane
Adhesive
MDP
(psf)
LWIC (See Note 15)
Deck
Type
LWC-7.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5
LWC-8.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Elastizell
290
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5
LWC-9.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Concrecel
290
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5
LWC-10.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-52.5
LWC-11.
Structural concrete
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-102.5
LWC-12.
Structural concrete
Elastizell
220
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-200.0
LWC-13.
Structural concrete
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-205.0
LWC-14.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
EverGuard WB181 Bonding Adhesive
-225.0
LWC-15.
Structural concrete
Elastizell
300
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 6-inch o.c.
-45.0
LWC-16.
Structural concrete
Mearlcrete
730
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 6-inch o.c.
-45.0
Structural concrete
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
LRF-M, ribbons 4-inch o.c.
-92.5
LWC-18.
Structural concrete
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
LRF-O, ribbons 4-inch o.c.
-112.5
LWC-19.
Structural concrete
Elastizell
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-210.0
LWC-20.
Structural concrete
Mearlcrete or Insulcel
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-270.0
LWC-21.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
LRF-M, 4-inch o.c.
-225.0
LWC-22.
Structural concrete
Celcore Cellular Concrete
200
2
EverGuard PVC XK Fleeceback
LRF-M or LRF-O, 4-inch o.c.
-300.0
LWC-17.
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 28 of 39
TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
Roof Deck (See Note 1)
System
No.
Roof Cover
LWIC (See Note 15)
Deck
Type
Min. Compressive
Strength (psi)
Min.
Thick (in)
LWC-23.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5
LWC-24.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5
LWC-25.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Elastizell
290
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5
LWC-26.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Concrecel
290
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-52.5
LWC-27.
Min. 22 ga., type BV, Grade
33 steel at max. 6 ft spans
Elastizell
160
3
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-60.0
LWC-28.
Structural concrete
Cellular lightweight insulating concrete; Note: To qualify
the LWC under this assembly, a Drill-Tec™ Base Sheet
Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7
in.) shall achieve an average withdrawal of 97 lbf or
greater when tested per ANSI/SPRI FX-1 or TAS105.
180
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-102.5
LWC-29.
Structural concrete
Elastizell
220
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-200.0
LWC-30.
Structural concrete
Mearlcrete
290
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-205.0
LWC-31.
Structural concrete
Concrecel
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-225.0
LWC-32.
Structural concrete
Insulcel
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-270.0
LWC-33.
Structural concrete
Celcore Cellular Concrete
200
2
EverGuard PVC XK Fleeceback
GAF 2-Part, spatter
-300.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Adhesive
MDP
(psf)
Membrane
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 29 of 39
TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Deck
(See Note 1)
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP (psf)
CWF-1.
Min. 2-inch Tectum Plank
or Tectum LS Plank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, EnergyGuard
Ultra, ACFoam III
OB500
(Optional) Additional layers of base
insulation
OB500
EverGuard PVC Smooth or PVC XK /
#2331
-45.0
CWF-2.
Min. 2-inch Tectum Plank
or Tectum LS Plank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, EnergyGuard
Ultra, ACFoam III, Min. 2-inch Styrofoam Deckmate
Plus FA or Min. 1-inch Foamular 250
OB500
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or PVC XK /
#2331
-45.0
CWF-3.
Min. 2-inch Tectum Plank
or Tectum LS Plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Additional layers of base
insulation
OB500
EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c.
-45.0
CWF-4.
Min. 2-inch Tectum Plank
or Tectum LS Plank
(Optional) Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c.
-45.0
CWF-5.
Min. 2-inch Tectum Plank
or Tectum LS Plank
Min. 1-inch EnergyGuard Polyiso Insulation,
EnergyGuard RH
LRF-M
(Optional) Additional layers of base
insulation
LRF-M
EverGuard PVC XK Fleeceback / LRFM, 12-inch o.c.
-45.0
CWF-6.
Min. 2-inch Tectum Plank
or Tectum LS Plank or
Fibroplank
Min. 1.5-inch thick EnergyGuard Polyiso Insulation,
EnergyGuard RA or ACFoam III
GAF 2-Part
(Optional) Additional layer of Base
Insulation
GAF 2-Part
EverGuard PVC Smooth or PVC XK /
#2331
-52.5
CWF-7.
Min. 2-inch Tectum Plank
or Tectum LS Plank or
Fibroplank
Min. 1.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard RA, EnergyGuard RN, ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part
EverGuard PVC Smooth or PVC XK /
#2331
-52.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 30 of 39
TABLE 6A: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Deck (See Note 1 & 12)
G-1.
Existing poured gypsum
or gypsum plank
Min. 1-inch EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
(Optional) Additional layers of base
insulation
G-2.
Existing poured gypsum
or gypsum plank
Min. 1-inch EnergyGuard RA
OB500
G-3.
Existing poured gypsum
or gypsum plank
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
EnergyGuard Ultra, ACFoam III, Min. 2-inch
Styrofoam Deckmate Plus FA or Min. 1-inch
Foamular 250
G-4.
Existing poured gypsum
or gypsum plank
G-5.
Existing poured gypsum
or gypsum plank
Roof Cover / Adhesive
MDP (psf)
OB500
EverGuard PVC XK Fleeceback / LRF-M,
6-inch o.c.
-45.0
None
N/A
EverGuard PVC-50, -60 or -80 / #2331
-262.5
OB500
Min. 0.25-inch Dens Deck or
SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC-50, -60 or -80 / #2331
-112.5
Min. 1-inch EnergyGuard RH
LRF-M
None
N/A
EverGuard PVC Smooth / #2331
-352.5
Min. 1.5-inch EnergyGuard RA, EnergyGuard RN,
ACFoam III
GAF 2-Part
Min. 0.25-inch Dens Deck or
SECUROCK Gypsum-Fiber Roof
Board
GAF 2-Part
EverGuard PVC-50, -60 or -80 / #2331
-240.0
Type
Attach
Type
Attach
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
Base Insulation Layer
Type
Top Insulation Layer
Fasten
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC SMOOTH OR PVC XK APPLICATIONS:
G-6.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-7.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-8.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra followed by min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-9.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra followed by min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
G-10.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
2
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 31 of 39
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
G-11.
Existing poured
gypsum or
gypsum plank
Base Insulation Layer
Type
Top Insulation Layer
Roof Cover / Adhesive
MDP
(psf)
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or min. 1.5-inch EnergyGuard
RH
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
1 per 2 ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min. 1.5-inch
EnergyGuard RH followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min. 1.5-inch
EnergyGuard RH followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth or
PVC XK / #2331
-45.0*
Fasten
Attach
Type
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or min. 1.5-inch EnergyGuard
RH
G-12.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
G-13.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
G-14.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
G-15.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Attach
EVERGUARD PVC XK FLEECEBACK APPLICATIONS:
G-16.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-17.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-18.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra followed by min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
G-19.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra followed by min.
0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
2
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 32 of 39
TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER
System
No.
Deck
(See Note 1)
G-20.
Existing poured
gypsum or
gypsum plank
G-21.
Base Insulation Layer
Type
Top Insulation Layer
Roof Cover / Adhesive
MDP
(psf)
LRF-M
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or min. 1.5-inch EnergyGuard
RH
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
1 per 2.9
ft2
Min. 0.5-inch EnergyGuard Polyiso Insulation,
EnergyGuard Ultra or min. 1.5-inch EnergyGuard
RH
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
1 per 2 ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min. 1.5-inch
EnergyGuard RH followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2.9
ft2
Optional min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or min. 1.5-inch
EnergyGuard RH followed by min. 0.25-inch Dens
Deck Prime or SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c.
-45.0*
Fasten
Attach
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 3.2
ft2
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
1 per 2 ft2
G-22.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
G-23.
Existing poured
gypsum or
gypsum plank
Min. 1.5-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
Drill-Tec Polymer Gyptec with
Drill-Tec 3” Gyptec Plates (Min. 2inch embedment)
G-24.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra or
EnergyGuard RH
G-25.
Existing poured
gypsum or
gypsum plank
Min. 2-inch EnergyGuard
Polyiso Insulation,
EnergyGuard Ultra
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Type
Attach
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 33 of 39
TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
Top Insulation Layer
System
No.
Deck
(See Note 1)
Base Insulation Layer
G-26.
Existing poured
gypsum or
gypsum plank
(Optional) One or more
layers, any combination
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3”
Gyptec Plates (Min. 2-inch embedment)
G-27.
Existing poured
gypsum or
gypsum plank
(Optional) One or more
layers, any combination
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH
G-28.
Existing poured
gypsum or
gypsum plank
(Optional) One or more
layers, any combination
G-29.
Existing poured
gypsum or
gypsum plank
(Optional) One or more
layers, any combination
Roof Cover / Adhesive
MDP (psf)
1 per 2 ft2
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
Drill-Tec Polymer Gyptec with Drill-Tec 3”
Gyptec Plates (Min. 2-inch embedment)
1 per 2.9 ft2
EverGuard PVC Smooth or PVC XK /
#2331
-45.0*
Min. 1.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3”
Gyptec Plates (Min. 2-inch embedment)
1 per 2 ft2
EverGuard PVC XK Fleeceback /
WB181 or LRF-M or LRF-O, 12-inch
o.c.
-45.0*
Min. 2-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra,
EnergyGuard RH
Drill-Tec Polymer Gyptec with Drill-Tec 3”
Gyptec Plates (Min. 2-inch embedment)
1 per 2.9 ft2
EverGuard PVC XK Fleeceback /
WB181 or LRF-M or LRF-O, 12-inch
o.c.
-45.0*
Type
Fasteners
Attach
TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF)
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System No.
Roof Deck
Roof Cover / Adhesive
MDP (psf)
G-30.
Existing poured gypsum or gypsum plank
EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c.
-45.0
G-31.
Existing poured gypsum or gypsum plank
EverGuard PVC XK Fleeceback / LRF-O, 6-inch o.c.
-45.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 34 of 39
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Substrate
(See Notes 1 & 12)
Base Insulation Layer
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC APPLICATIONS:
R-1.
Existing asphaltic BUR or mineral surfaced cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, EnergyGuard Ultra,
ACFoam III, Min. 2-inch Styrofoam
Deckmate Plus FA or Min. 1-inch
Foamular 250
R-2.
Existing asphaltic BUR or mineral surfaced cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RN, ACFoam III
GAF 2Part
Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board
GAF 2Part
EverGuard PVC-50, -60 or
-80 / #2331
-240.0
OB500
Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board
OB500
EverGuard PVC-50, -60 or
-80 / #2331
-120.0
EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS:
R-3.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
None
N/A
EverGuard PVC Smooth
or PVC XK / #2331
-45.0
R-4.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
None
N/A
EverGuard PVC Smooth
or PVC XK / #2331
-225.0
R-5.
Existing smooth surfaced BUR / APP modified
bitumen or granule surfaced roof cover over
struct conc. deck
(Optional) Min. 1.5-inch EnergyGuard
RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC Smooth
or PVC XK / #2331
-97.5
R-6.
Existing asphaltic BUR or mineral surfaced cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
(Optional) Additional layers of base insulation
OB500
EverGuard PVC Smooth
or PVC XK / #2331
-120.0
R-7.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC Smooth
or PVC XK / #2331
-225.0
R-8.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC Smooth
or PVC XK / #2331
-202.5
R-9.
Existing asphaltic BUR or mineral surfaced cap
sheet
Min. 1.5-inch EnergyGuard RA,
EnergyGuard RH, EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime or SECUROCK
Gypsum-Fiber Roof Board
OB500
EverGuard PVC Smooth
or PVC XK / #2331
-120.0
R-10.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC Smooth
or PVC XK / #2331
-45.0
R-11.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC Smooth
or PVC XK / #2331
-75.0
R-12.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC Smooth
or PVC XK / #2331
-225.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 35 of 39
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
System
No.
Base Insulation Layer
Substrate
(See Notes 1 & 12)
Type
Top Insulation Layer
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
R-13.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC Smooth
or PVC XK / #2331
-75.0
R-14.
Existing smooth surfaced BUR or granule
surfaced roof cover
(Optional) Min. 1.5-inch EnergyGuard
RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC Smooth
or PVC XK / #2331
-75.0
R-15.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC Smooth
or PVC XK / #2331
-225.0
R-16.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth
or PVC XK / #2331
-75.0
R-17.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC Smooth
or PVC XK / #2331
-202.5
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN WB181 BONDING ADHESIVE:
R-18.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
None
N/A
EverGuard PVC XK
Fleeceback / WB181
-90.0
R-19.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK
Fleeceback / WB181
-90.0
R-20.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK
Fleeceback / WB181
-90.0
R-21.
Existing smooth surfaced BUR / APP modified
bitumen or granule surfaced roof cover over
struct conc. deck
(Optional) Min. 1.5-inch EnergyGuard
RH
OB500
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
OB500
EverGuard PVC XK
Fleeceback / WB181
-97.5
R-22.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC XK
Fleeceback / WB181
-75.0
R-23.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC XK
Fleeceback / WB181
-90.0
R-24.
Existing smooth surfaced BUR or granule
surfaced roof cover
(Optional) Min. 1.5-inch EnergyGuard
RH
LRF-M
Min. 0.5-inch EnergyGuard RH HD Polyiso
Insulation, EnergyGuard HD Polyiso Insulation,
EnergyGuard HD Plus Polyiso Insulation
LRF-M
EverGuard PVC XK
Fleeceback / WB181
-75.0
R-25.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK
Fleeceback / WB181
-75.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 36 of 39
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Substrate
(See Notes 1 & 12)
R-26.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK
Fleeceback / WB181
-90.0
R-27.
Existing smooth-surfaced BUR over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181
-75.0
R-28.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK
Fleeceback / WB181
-90.0
Type
Attach
Type
Attach
Roof Cover / Adhesive
MDP
(psf)
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN LRF ADHESIVE M OR LRF ADHESIVE O:
R-29.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
OB500
None
N/A
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-45.0
R-30.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or
ACFoam IV
OB500
None
N/A
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-60.0
R-31.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK
Fleeceback / LRF-M, 12inch o.c.
-37.5
R-32.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch Dens Deck Prime
OB500
EverGuard PVC XK
Fleeceback / LRF-O, 12inch o.c.
-45.0
R-33.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
OB500
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
OB500
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-45.0
R-34.
Existing smooth- or granule-surfaced BUR;
smooth- or granule-surfaced SBS modified
bitumen or granule-surfaced APP modified
bitumen over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 4-inch o.c.
-180.0
R-35.
Existing granule-surfaced BUR, granule-surfaced
modified bitumen or smooth-surfaced SBS
modified bitumen
Min. 1-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra
LRF-M
None
N/A
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-45.0
R-36.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc.
deck
Min. 0.5-inch EnergyGuard Polyiso
Insulation, EnergyGuard Ultra or
ACFoam IV
LRF-M
None
N/A
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-60.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 37 of 39
TABLE 7A: RECOVER APPLICATIONS
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
Base Insulation Layer
Top Insulation Layer
System
No.
Substrate
(See Notes 1 & 12)
R-37.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc.
deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
LRF-M
Min. 0.25-inch Dens Deck Prime
R-38.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc.
deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
LRF-M
R-39.
Existing smooth- or granule-surfaced BUR,
granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc.
deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RA, EnergyGuard RH,
EnergyGuard RN
R-40.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
R-41.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
Roof Cover / Adhesive
MDP
(psf)
LRF-M
EverGuard PVC XK
Fleeceback / LRF-M, 12inch o.c.
-37.5
Min. 0.25-inch Dens Deck Prime
LRF-M
EverGuard PVC XK
Fleeceback / LRF-O, 12inch o.c.
-45.0
LRF-M
Min. 0.25-inch SECUROCK Gypsum-Fiber Roof
Board
LRF-M
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 12-inch o.c.
-45.0
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 4-inch o.c.
-180.0
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK
Fleeceback / LRF-M or
LRF-O, 4-inch o.c.
-180.0
Type
Attach
Type
Attach
EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN GAF 2-PART ROOFING ADHESIVE:
R-42.
Existing smooth- or granule-surfaced BUR;
smooth- or granule-surfaced SBS modified
bitumen or granule-surfaced APP modified
bitumen over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
OB500
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
OB500
EverGuard PVC XK
Fleeceback / GAF 2-Part,
spatter
-180.0
R-43.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
LRF-M
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
LRF-M
EverGuard PVC XK
Fleeceback / GAF 2-Part,
spatter
-180.0
R-44.
Existing smooth- or granule-surfaced BUR or
smooth- or granule-surfaced modified bitumen
over struct conc. deck
(Optional) Min. 0.5-inch EnergyGuard
Polyiso Insulation, EnergyGuard Ultra,
EnergyGuard RH, EnergyGuard RN
GAF 2Part
Optional additional layers base insulation
followed by min. 0.25-inch Dens Deck Prime or
SECUROCK Gypsum-Fiber Roof Board
GAF 2Part
EverGuard PVC XK
Fleeceback / GAF 2-Part,
spatter
-180.0
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 38 of 39
TABLE 7B: RECOVER APPLICATIONS
SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER
System
No.
Substrate (See Note 12)
Roof Cover / Adhesive
MDP (psf)
R-45.
Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c.
-45.0
R-46.
Existing asphaltic granule surfaced roof cover over steel deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c.
-60.0
R-47.
Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen
over steel deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c.
-60.0
R-48.
Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen
over structural concrete deck
EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c.
-337.5
R-49.
Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-45.0
R-50.
Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over steel
deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-60.0
R-51.
Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over
structural concrete deck
EverGuard PVC XK Fleeceback / GAF 2-Part, spatter
-337.5
Exterior Research and Design, LLC. d/b/a Trinity|ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
Evaluation Report 01506.09.04-R21 for FL3443-R18
Revision 21: 02/12/2016
Appendix 1, Page 39 of 39