Florida Building Code Online BCIS Home Log In User Registration Page 1 of 2 Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL3443-R18 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (973) 872-4421 lindareith@trinityerd.com Authorized Signature Beth McSorley lindareith@trinityerd.com Technical Representative Beth McSorley (current) Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (973) 872-4421 bmcsorley@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Single Ply Roof Systems Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/07/2016 Validated By John W. Knezevich, PE Certificate of Independence Referenced Standard and Year (of Standard) Validation Checklist - Hardcopy Received FL3443_R18_COI_2016_01_COI_Nieminen.pdf Standard Year ASTM D4434 2009 FM 4470 1992 FM 4474 2004 TAS 114 2011 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvbK%2bEQBZ... 4/15/2016 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 02/14/2016 Date Validated 02/16/2016 Date Pending FBC Approval 02/17/2016 Date Approved 04/12/2016 Summary of Products FL # Model, Number or Name Description 3443.1 EverGuard PVC Single-Ply Roof Systems Internally reinforced thermoplastic roof covers Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-502.5 Other: 1.) The design pressure noted in this application pertains to one specific assembly over one specific deck type. Refer to the ER Appendix for all deck types, systems and maximum design pressures. 2.) Refer to ER Section 5 for Limits of Use. Back Installation Instructions FL3443_R18_II_2016_02_FINAL_A1_ER_GAF_PVC_FL3443R18.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL3443_R18_AE_2016_02_FINAL_ER_GAF_PVC_FL3443R18.pdf Created by Independent Third Party: Yes Next Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvbK%2bEQBZ... 4/15/2016 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street, Unit 13 Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF 1 Campus Drive Parsippany, NJ 07054 Evaluation Report 01506.09.04-R21 FL3443-R18 Date of Issuance: 07/20/2005 Revision 21: 02/12/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: EverGuard® PVC Single-Ply Roof Membrane Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity|ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “TRINITY|ERD Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 39-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 02/12/2016. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity|ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity|ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems ® Compliance Statement: EverGuard PVC Single-Ply Roof Membrane Systems, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. 3. STANDARDS: Section Property Standard Year 1504.3.1 1504.7 1507.13.2 1523.6.2 Wind Impact Physical Properties Wind FM 4474 FM 4470 ASTM D4434 TAS 114 2004 1992 2009 2011 Entity Examination Reference Date ATI (TST1558) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ACRC (TST4671) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) FET (TST7393) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) Physical Properties TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties FM 4470 / 4474 FM 4470 / 4474 TAS 114 FM 4470 FM 4470 FM 4470 52825.01-106-31 06-047 07-001 07-002 07-007 07-029 07-031 08-031 11-057 11-058 11-059 11-060 11-061 11-062 11-063 11-066 12-005 12-006 12-007 12-009 12-010 12-011 12-021 12-022 12-017 12-020 12-027 12-028 12-032 11-015-R1 11-018-R1 11-022-R1 F35940.10.11-2-R2 F35940.12.11-R2 F42130.06.13 F42130.06.13-1 F42130.09.13 GAF-SC8580.14 GAF-SC8580.14 08-050182 3003956 3003955 3014692 06/15/2005 12/21/2006 01/12/2007 01/12/2007 01/19/2007 03/08/2007 05/09/2007 05/05/2008 09/30/2011 10/03/2011 10/04/2011 10/05/2011 10/06/2011 10/07/2011 10/08/2011 11/21/2011 04/09/2012 04/09/2012 04/10/2012 04/20/2012 04/20/2012 04/20/2012 04/26/2012 04/26/2012 05/07/2012 05/08/2012 05/22/2012 05/22/2012 08/23/2012 08/29/2012 08/29/2012 08/29/2012 02/27/2012 02/27/2012 06/05/2013 06/05/2013 09/13/2013 03/25/2015 07/20/2015 06/26/2008 02/18/2000 03/05/2002 08/05/2003 REFERENCES: Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.09.04-R21 FL3443-R18 Revision 21: 02/12/2016 Page 2 of 5 Entity Examination Reference Date FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) IRT (TST5296) MTI (TST2508) MTI (TST2508) MTI (TST2508) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) UL, LLC. (QUA9625) UL, LLC. (QUA9625) UL, LLC. (QUA9625) UL, LLC. (QUA9625) FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 TAS 114 ASTM D4434 ASTM D4434 ASTM D4434 Physical Properties Component Performance Component Performance Component Performance Component Performance FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 Comparative Pull-Off FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 FM 4470 / 4474 Quality Control Quality Control Quality Control Quality Control 3024709 3023368 3028606 3026964 3031127 3033126 3034394 3037879 797-07043-267 3044862 3044914 3045789 3046328 3041769 3046403 797-07886-267 797-07849-267 3046054 3047606 3048122 797-08217-267 3047237 3047636 797-08873-267 3048066 797-09116-267 797-09495-267 797-09594-267 797-09892-267 04-006 NX21J0A NX21J0B NX21J0C GAF-373-02-01 GAF-462-02-01 GAF-462-02-02 GAF-462-02-03 GAF-462-02-04 GAF-457-02-02 GAF-457-02-04 GAF-457-02-06 GAF-457-02-07 GAF-457-02-08 GAF-435-02-01 GAF-435-02-11 GAF-510-02-02 GAF-515-02-01 GAF-515-02-03 GAF-516-02-03 GAF-525-02-02 GAF-525-02-03 GAF-462-02-07 GAF-462-02-08 GAF-462-02-09 GAF-462-02-10 GAF-462-02-11 GAF-538-02-03 ML File No. R1306, R9228 ML File No. R1306, R21864 Inspection Report, PA Inspection Report, NJ 10/21/2005 03/20/2006 02/23/2007 07/25/2007 10/01/2007 07/11/2008 02/27/2009 02/04/2010 01/16/2012 05/11/2012 06/18/2012 07/12/2012 09/13/2012 09/27/2012 09/28/2012 11/21/2012 12/03/2012 12/21/2012 02/26/2013 04/29/2013 05/01/2013 07/15/2013 08/08/2013 11/26/2013 12/13/2013 01/24/2014 05/27/2014 06/24/2014 08/12/2014 02/16/2004 06/01/2011 07/20/2011 06/01/2011 10/15/2012 11/15/2013 11/18/2013 11/18/2013 11/18/2013 01/20/2014 01/24/2014 01/24/2014 01/24/2014 01/24/2014 01/29/2014 01/29/2014 04/08/2014 05/13/2014 05/13/2014 05/13/2014 06/23/2014 06/23/2014 07/01/2014 07/01/2014 07/01/2014 07/01/2014 07/01/2014 08/13/2014 01/27/2015 03/11/2015 08/07/2015 11/20/2015 Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.09.04-R21 FL3443-R18 Revision 21: 02/12/2016 Page 3 of 5 4. PRODUCT DESCRIPTION: This Evaluation Report covers EverGuard® PVC Single-Ply Roof Membrane Systems installed in accordance with GAF published installation instructions and the Limitations / Conditions of Use herein. ® ® ® EverGuard PVC-50, EverGuard PVC-60 and EverGuard PVC-80 membranes are nominal 50-mil (1.3 mm), 60-mil (1.5-mm) or 80-mil (2.0 mm) thick, internally reinforced thermoplastic (PVC) roof covers, available in 81 and 40.5inch wide rolls. ® EverGuard PVC Smooth membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, polyester scrim reinforced, thermoplastic (PVC) single-ply roof membranes, available in 120 and 60-inch wide rolls. ® EverGuard PVC XK membranes are nominal 50-mil (1.2-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic ® fiber reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membranes, available in 120 and 60-inch wide rolls. ® EverGuard PVC XK Fleeceback membranes are nominal 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, synthetic fiber ® reinforced, thermoplastic (PVC/Elvaloy ) single-ply roof membrane with a nonwoven polyester felt backing, available in 120 and 76-inch wide rolls. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 or 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, RAS 137, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, TAS 124 or ANSI/SPRI IA-1 shall be conducted on mock-ups of the proposed new roof assembly. Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.09.04-R21 FL3443-R18 Revision 21: 02/12/2016 Page 4 of 5 6. 7. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. INSTALLATION: ® 6.1 EverGuard PVC Single-Ply Roof Membrane Systems shall be installed in accordance with GAF published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact named QA entity for details on manufacturing facilities covered for QA under F.A.C. Rule 61G20-3 requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. – QUA9625; (314) 578-3406; k.chancellor@ul.com - THE 39-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Certificate of Authorization #9503 Evaluation Report 01506.09.04-R21 FL3443-R18 Revision 21: 02/12/2016 Page 5 of 5 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table 1A 1B 1C 1D 2A-1 2A-2 2B-1A 2B-1B 2B-2 2C 3A 3B 4A 4B 4C 5A 6A 6B 6C 6D 7A 7B Deck Wood Wood Wood Wood Steel or Conc. Steel or Conc. Steel or Conc. Steel or Conc. Steel or Conc. Steel Concrete Concrete LWIC LWIC LWIC CWF Gypsum Gypsum Gypsum Gypsum Various Concrete Application New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New, Reroof (Tear-Off) or Recover New or Reroof (Tear-Off) New or Reroof (Tear-Off) New or Reroof (Tear-Off) New or Reroof (Tear Off) New or Reroof (Tear-Off) New or Reroof (Tear-Off) Reroof (Tear-Off) Reroof (Tear-Off) Reroof (Tear-Off) Reroof (Tear-Off) Recover Recover Type B-1 C-1 C-2 D-1 B-1 B-2 C-1 C-1A C-2 D-1 A-1 F A-1 E F A-1 A-1 B-1 C-1 F A-1 F Description Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Mechanically Attached Insulation, Bonded Roof Cover Plate-Bonded Roof Cover Mechanically Attached Roof Cover Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Mechanically Attached Thermal Barrier, Bonded Temp Roof, Bonded Insulation, Bonded Roof Cover Mechanically Attached Insulation, Bonded Roof Cover Thermal Barrier with Vapor Barrier, Mechanically Attached Insulation, Bonded Roof Cover Mechanically Attached Insulation, Plate-Bonded Roof Cover Mechanically Attached Roof Cover Bonded Insulation, Bonded Roof Cover Non-Insulated, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Non-Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover Non-Insulated, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Mechanically Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover Mechanically Attached Insulation, Bonded Roof Cover Non-Insulated, Bonded Roof Cover Bonded Insulation, Bonded Roof Cover Non-Insulated, Bonded Roof Cover Page 4 4 5 5 6-12 13 14-16 17-18 19 20 21-26 26 27 27 28-29 30 31 31-33 34 34 35-38 39 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood Deck: Drill-Tec #12 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. ¾-inch plywood penetration or minimum 1-inch wood plank embedment. Steel Deck: Drill-Tec #12 Fastener, Drill-Tec #14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only). Minimum ¾-inch steel penetration, engage the top flute of the steel deck. Concrete Deck: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3” Standard Steel Plate, Drill-Tec 3” Steel Plate or Drill-Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only) or Drill-Tec Heavy Duty ASAP 3S. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 1 of 39 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. A separator is required when using polystyrene insulation with smooth-backed EverGuard® PVC membranes (EverGuard® PVC XK, EverGuard® PVC Smooth and EverGuard® PVC-50; 60; 80). Refer to GAF published installation instructions for details and requirements regarding the use of polystyrene insulation in EverGuard® roofing systems: Insulation: Expaned polystyrene (EPS) meeting or exceeding ASTM C578, Type II, nominal 1.5 lb/ft2 density and minimum 15 psi compressive strength. Expanded polystyrene (EPS) with plastic facer meeting or exceeding ASTM C578, Type II, nominal 1.5 lb/ft2 density and minimum 15 psi compressive strength. High Traffic Applications: Extruded polystyrene (XPS) meeting or exceeding ASTM C578, Type IV, minimum 1-inch thick and minimum 25 psi compressive strength. Expanded polystyrene (EPS) with plastic facer meeting or exceeding ASTM C578, Type IX, minimum 1-inch thick and minimum 25 psi compressive strength. Recover Applications: XPS Fan-Fold Recover Board with plastic facer meeting or exceeding ASTM C578, Type IV, 3/8-inch thick and minimum 25 psi compressive strength. EPS Recover Board meeting or exceeding ASTM C578, Type IV, 1/2-inch thick and minimum 25 psi compressive strength. EPS Recover Board with plastic facer meeting or exceeding ASTM C578, Type II, 1/2-inch thick and minimum 15 psi compressive strength. TOPCOAT® FireOut™ Fire Barrier Coating, VersaShield® Fire-Resistant Roof Deck Protection or VersaShield® Solo™ Fire-Resistant Slip Sheet, installed in accordance with GAF published installation instructions and fire resistance certification listings, may be used as a non-load-bearing, fire-barrier / slip-sheet component within any system outlined herein. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete (LWIC) may be substituted for or installed below the rigid insulation board for System Type C-1 (mechanically attached insulation, bonded roof cover), System Type C-2 (plate-bonded roof cover) or System Type D-1 (mechanically attached membrane), whereby the insulation or membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. For Type C-1, the top insulation layer shall be that specified in the applicable Table. For Type C-2 or D-1, if the LWIC is installed below, the rigid insulation board may consist of min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation, EnergyGuard RH HD Polyiso Insulation or Structodek High Density Fiberboard Roof Insulation or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board, SECUROCK Glass-Mat Roof Board or Dens Deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-relatated issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5. Preliminary insulation attachment for System Type D-1 = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. Hot Asphalt (HA): Full mopping, 25-30 lbs/square. OlyBond 500 (OB500): Continuous ¾ to 1-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 500 Green may be used where OlyBond 500 is referenced. GAF LRF Adhesive M (LRF-M): Continuous 1-inch wide ribbons, 12-inch o.c GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-inch ribbons, 12-inch o.c. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. Hot Asphalt (HA): MDP = -240.0 psf (Min. 0.5-inch thick) OlyBond 500 (OB500): MDP = -292.5 psf (Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra) OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick EnergyGuard RN or RH) OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick EnergyGuard RA) GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 2 of 39 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, RAS 137, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 12. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, TAS 124 or ANSI/SPRI IA-1. 13. For System Type D-1, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Recover Applications using System Type C-2 or any System Type D, the insulation is optional. Alternatively, a separator board may be installed prior to roof cover installation when using System Type C-2 or any System Type D or a separator sheet may be installed prior to roof cover installation when using any System Type D. The existing roof system shall be suitable for a recover application. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.6, when installed with the roof cover in Recover applications. Separator Board Options for Recover System Type C-2 or System Type D: Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation or EnergyGuard HD Plus Polyiso Insulation, or min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board. Separator Sheet Options for Recover System Type D: EverGuard Polymat Separation Layer (3 oz/yd2) or EverGuard Polymat Cushioning Layer (6 oz/yd2). 15. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum topcoat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. 16. For adhesive-applied membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows: Membrane EverGuard PVC-50, -60 or -80 EverGuard PVC Smooth or PVC XK EverGuard PVC XK Fleeceback EverGuard PVC XK Fleeceback Adhesive EverGuard #2331 Bonding Adhesive (#2331) EverGuard #2331 Bonding Adhesive (#2331) Hot asphalt EverGuard WB181 Bonding Adhesive (WB181) Method Contact (both sides) Contact (both sides) Wet lay (substrate) Wet lay (substrate) EverGuard PVC XK Fleeceback GAF LRF Adhesive M (LRF-M) or LRF Adhesive O (LRF-O) Wet lay (substrate) EverGuard PVC XK Fleeceback GAF 2-Part Roofing Adhesive (GAF 2-Part) Wet lay (substrate) Rate 1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane) 1.67 to 1.80 gal/square (½ applied to substrate and ½ applied to membrane) 25 lbs/square 0.83 to 1.0 gal/square 1-inch wide ribbons spaced as noted in tables herein. Note: The adhesive ribbons are located directly over the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than 1.5-inch thick. “Spatter pattern” at 3.75 lbs/sq. 17. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 3 of 39 TABLE 1A: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Fasten Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: W-1. Min. 15/32-inch plywood or wood plank at max. 2 ft spans Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH See Note 2 (#14 Fastener only) 1 per 2 ft2 Min. 0.25-inch SECUROCK GypsumFiber Roof Board LRF-M, OB500 or GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5 See Note 2 (#14 Fastener only) 1 per 2 ft2 Min. 0.25-inch SECUROCK GypsumFiber Roof Board LRF-M, OB500 or GAF 2-Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -52.5 EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: W-2. Min. 15/32-inch plywood or wood plank at max. 2 ft spans Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH TABLE 1B: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. W-3. Deck (See Note 1) Min. 23/32-inch plywood; 24inch spans Base Insulation Layer One or more layers, min. 1.5inch ASTM C1289 insulation Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Top Insulation Layer Type Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board Fasteners See Note 2 Attach 1 per 2 ft2 Roof Cover / Adhesive EverGuard PVC-50, -60 or -80 / #2331 MDP (psf) -45.0* Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 4 of 39 TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER System No. Deck (See Note 1) Attachment Insulation Layer Fasteners W-4. Min. 15/32-inch plywood; 24-inch span One or more layers, any combination, (Tread Safe = min. 2-inch) W-5. Min. 15/32-inch plywood over nominal No. 2 wood trusses spaced max. 24inch o.c. (Optional) One or more layers, any combination, preliminarily attached (Tread Safe = min. 2-inch thick insulation) Roof Cover MDP (psf) 1 per 2.67 ft² (12 parts per 4 x 8 ft board) Fasteners are 6-, 24- and 42-inches from the board’s long edge and 12-, 36-, 60- and 84inches from the board’s short edge. EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -52.5 18-inch o.c. along wood supports, 24-inch o.c. EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -82.5 Density Drill-Tec #14 Fastener and Drill-Tec RhinoBond PVC XHD Plates or DrillTec RhinoBond PVC XHD Tread Safe Plates Drill-Tec #14 (min. 1-inch embedment) and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates through to wood supports TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER System No. Deck (See Note 1) Insulation Type Roof Cover Attach Membrane Fasteners Attachment MDP (psf) W-6. Min. 15/32-inch plywood; 24-inch span One or more layers, any combination, min. 0.5-inch Prelim. Attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 9-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld. -30.0 W-7. Min. 23/32-inch plywood; 24-inch spans (Optional) One or more layers, any combination Prelim. attach EverGuard PVC50, -60 or -80 Trufast EHD with Trufast 2.4-inch Barbed Seam Plates 12-inch o.c. within 5.5-inch wide laps spaced 75.5-inch o.c. and sealed with a 1.5-inch heat weld. -37.5 W-8. Min. 15/32-inch plywood; 24-inch span One or more layers, any combination, min. 0.5-inch Prelim. Attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld. -37.5 W-9. Min. 19/32-inch plywood; 24-inch span One or more layers, any combination, min. 0.5-inch Prelim. attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 8-inch o.c. within 5-inch wide laps spaced 55inch o.c. and sealed with a 1.5-inch heat weld. -45.0 W-10. Min. 19/32-inch plywood; 24-inch span One or more layers, any combination, min. 0.5-inch Prelim. attach EverGuard PVC XK or PVC Smooth Drill-Tec #14 Fastener with Drill-Tec 2 in. Double Barbed XHD Plates, Drill-Tec 2-3/8-inch Barbed XHD Plates or Drill-Tec Eyehook AccuSeam Plate 6-inch o.c. within 5-inch wide laps spaced 76inch o.c. and sealed with a 1.5-inch heat weld. -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 5 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-1. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Additional layers of base insulation Hot asphalt EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-2. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2.0-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 4 ft2 Additional layers of base insulation Hot asphalt EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-3. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-4. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-5. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-EnergyGuard RH See Note 2 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-6. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-7. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-8. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-9. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch thick SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-10. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-11. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 4 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-12. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 6 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-13. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-14. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.5-inch Dens Deck See Note 2 1 per 2 ft2 One or more layers, min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-15. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-16. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-EnergyGuard RH See Note 2 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-17. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-18. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-19. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-20. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-21. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-22. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-23. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M, OB500 or GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 See Note 2 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -52.5 EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-24. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 -37.5* Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 7 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-25. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-26. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-27. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-28. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-29. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-30. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-31. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* S-32. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -37.5* S-33. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-EnergyGuard RH See Note 2 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -37.5* S-34. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-35. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-36. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 8 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-37. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-38. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-39. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -45.0* S-40. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Additional layers, min. 1.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / WB181 -45.0* S-41. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Additional layers, min. 1.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / WB181 -45.0* EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: S-42. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-43. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-44. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-45. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -30.0* S-46. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-47. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-48. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 9 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) S-49. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-50. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-51. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-52. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 Optional additional layers, min. 1.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-53. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-54. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-55. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-56. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-57. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -30.0* S-58. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-59. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-60. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 10 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. S-61. Deck (See Note 1) Min. 22 ga., Type B, Grade 33 steel or struct conc. Base Insulation Layer Type Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN Top Insulation Layer Type Attach Roof Cover / Adhesive MDP (psf) Fasten Attach See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: S-62. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -30.0* S-63. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-64. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-65. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-66. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-67. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -52.5 S-68. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -30.0* S-69. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-70. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-71. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-72. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 11 of 39 TABLE 2A-1: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Attach Roof Cover / Adhesive MDP (psf) Fasten Attach Type Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -52.5 S-73. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH See Note 2 1 per 2 ft2 S-74. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 3.2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -30.0* S-75. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-76. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Additional layers, min. 0.5-inch base insulation GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-77. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-78. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 Optional additional layers, min. 0.5-inch base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-79. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min 2-inch EnergyGuard Polyiso Insulation, EnergyGuard RH See Note 2 1 per 2 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 12 of 39 TABLE 2A-2: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) SYSTEM TYPE B-2: MECHANICALLY ATTACHED THERMAL BARRIER, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Thermal Barrier Type Fasten Temp Roof Attach Type Insulation Layer(s) Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-80. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board S-81. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board S-82. Min. 22 ga., Grade 33 steel or struct conc. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board S-83. Min. 22 ga., Grade 33 steel or struct conc. 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN followed by Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN followed by Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* 1 per 2.7 ft2 UnderRoof 2 PolyesterSurfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier Selfadhered Min. 1.5-inch EnergyGuard RH followed by Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -45.0* See Note 2 Min. 22 ga., Grade 33 steel or struct conc. (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) EVERGUARD PVC XK FLEECEBACK APPLICATIONS: S-84. Min. 22 ga., Grade 33 steel or struct conc. S-85. Min. 22 ga., Grade 33 steel or struct conc. S-86. Min. 22 ga., Grade 33 steel or struct conc. See Note 2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) See Note 2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 (Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) may be used) Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 13 of 39 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-87. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 3.2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -30.0* S-88. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -30.0* S-89. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2.67 ft2 EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-90. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.67 ft2 EverGuard PVC Smooth or PVC XK / #2331 -37.5* S-91. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-92. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-93. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RA, EnergyGuard RN or EnergyGuard RH See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-94. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-95. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-96. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.5-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-97. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-98. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-99. Min. 22 ga., Type B, Grade 33 steel or struct conc. One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-100. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation See Note 2 1 per 1.78 ft2 EverGuard PVC Smooth or PVC XK / #2331 -60.0 S-101. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH See Note 2 1 per 1.78 ft2 EverGuard PVC Smooth or PVC XK / #2331 -67.5 Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 EverGuard PVC XK Fleeceback / WB181 -30.0* EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-102. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 14 of 39 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) S-103. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.67 ft2 EverGuard PVC XK Fleeceback / WB181 -37.5* S-104. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* S-105. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* S-106. Min. 22 ga., Type B, Grade 33 steel or struct conc. One or more layers, any combination, min. 1.5-inch Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: S-107. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -30.0* S-108. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -37.5* S-109. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.67 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -37.5* S-110. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-111. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-112. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or ACFoam IV See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0 S-113. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination, min. 1.5-inch Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c. -37.5* S-114. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination, min. 1.5-inch Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0* S-115. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination, min. 1.5-inch Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0* S-116. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-117. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* S-118. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -60.0 S-119. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 15 of 39 TABLE 2B-1A: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. S-120. Deck (See Note 1) Min. 22 ga., Type B, Grade 33 steel or struct conc. Base Insulation Layer (Optional) One or more layers, any combination Top Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -67.5 EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: S-121. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra See Note 2 1 per 4 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -30.0* S-122. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 4 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -37.5* S-123. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.67 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -37.5* S-124. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-125. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN See Note 2 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-126. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard RH, EnergyGuard RN See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0 S-127. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0* S-128. Min. 22 ga., Type B, Grade 33 steel or struct conc. (Optional) One or more layers, any combination Min. 0.375-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 1.33 ft2 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -67.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 16 of 39 TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Top Insulation Layer Type Fasten Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: S-129. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck or min. 0.5-inch SECUROCK Glass-Mat Roof Board, loose-laid, followed by UnderRoof 2 PolyesterSurfaced Leak Barrier, UnderRoof HT High Temperature Leak Barrier or WeatherWatch XT Mat Surfaced Leak Barrier, selfadhered, followed by min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN or EnergyGuard Ultra, loose-laid S-130. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-131. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 2-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-132. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.25-inch Dens Deck Prime See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-133. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.5-inch Dens Deck Prime See Note 2 1 per 3.2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-134. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* S-135. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard RH, loose laid, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board See Note 2 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 0.625-inch Dens Deck Prime See Note 2 1 per 4 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 17 of 39 TABLE 2B-1B: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1A: THERMAL BARRIER WITH VAPOR BARRIER, MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. S-136. Deck (See Note 1) Base Insulation Layer Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Top Insulation Layer Roof Cover / Adhesive MDP (psf) 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 -45.0* Type Fasten Attach Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 Min. 1.5-inch EnergyGuard RH, loose laid, followed by min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation See Note 2 EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: S-137. Min. 22 ga., Type B, Grade 33 steel or struct conc. Min. 0.625-inch Dens Deck Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, loose-laid, covered with WeatherWatch XT Mat Surfaced Leak Barrier, UnderRoof 2 Polyester-Surfaced Leak Barrier or UnderRoof HT High Temperature Leak Barrier, selfadhered Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 18 of 39 TABLE 2B-2: STEEL OR CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: MECHANICALLY ATTACHED INSULATION, PLATE-BONDED ROOF COVER System No. Deck (See Note 1) Insulation Layer S-138. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, (Tread Safe = min. 2-inch) S-139. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Attachment Fasteners Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates Drill-Tec SXHD and Drill-Tec RhinoBond PVC XHD Plates Density 1 per 5.3 ft² (6 parts per 4 x 8 ft board) Fasteners located in each of the four corners of the board and at mid-span of the 96-inch length. Fasteners are 6-inches from the board’s long edges and 12-inches and 48-inches from the board’s short edges. 24 x 36 inch grid Roof Cover MDP (psf) EverGuard PVC-50, -60 or -90 bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -45.0* EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -45.0 1 per 4 ft² (8 parts per 4 x 8 ft board) Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. 24 x 24 inch grid EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -60.0 1 per 2.67 ft² (12 parts per 4 x 8 ft board) Fasteners are 6-, 24- and 42-inches from the board’s long edge and 12-, 36-, 60- and 84-inches from the board’s short edge. EverGuard PVC XK or EverGuard PVC Smooth bonded to Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates with RhinoBond Portable Bonding Tool, per manufacturer’s published instructions. -67.5 S-140. Min. 20 ga., type B, Grade 33 steel One or more layers, any combination, (Tread Safe = min. 2-inch) S-141. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination Drill-Tec SXHD and Drill-Tec RhinoBond PVC XHD Plates S-142. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, (Tread Safe = min. 2-inch) Drill-Tec XHD and Drill-Tec RhinoBond PVC XHD Plates or Drill-Tec RhinoBond PVC XHD Tread Safe Plates Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 -52.5 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 19 of 39 TABLE 2C: STEEL DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER System No. Insulation Deck (See Note 1) Type Roof Cover Attach Membrane Fasteners Attachment MDP (psf) EVERGUARD PVC-50, -60 OR -80: S-143. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 18-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld. -30.0 S-144. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 12-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld. -37.5 S-145. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 12-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld. -45.0 S-146. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2-inch Barbed Plates 6-inch o.c. within 6-inch wide laps spaced 75-inch o.c. and sealed with a 1.5-inch heat weld. -52.5 S-147. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC-50, -60 or -80 Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 6-inch o.c. within 5.5-inch wide laps spaced 75.5inch o.c. and sealed with a 1.5-inch heat weld. -75.0 EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK: S-148. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 6-inch o.c. within minimum 6-inch wide laps spaced maximum 114-inch o.c. and sealed with a 1.5-inch heat weld -30.0 S-149. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 6-inch o.c. within minimum 5.5-inch wide laps spaced maximum 114.5-inch o.c. and sealed with a 2-inch heat weld -37.5 S-150. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec SXHD #21 with Drill-Tec 2 ¾ in. Barbed SXHD Plates 12-inch o.c. within minimum 6-inch wide laps spaced maximum 114-inch o.c. and sealed with a 2-inch heat weld -37.5 S-151. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec #14 Fasteners with DrillTec 2 in. Barbed Plates 6-inch o.c. within 5-inch wide laps spaced 55-inch o.c. and sealed with a 2-inch heat weld. -45.0 S-152. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 6-inch o.c. within minimum 5.5-inch wide laps spaced maximum 75.5-inch o.c. and sealed with a 2-inch heat weld -45.0 S-153. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec SXHD #21 with Drill-Tec 2 ¾ in. Barbed SXHD Plates 12-inch o.c. within minimum 6-inch wide laps spaced maximum 75-inch o.c. and sealed with a 2-inch heat weld -45.0 S-154. Min. 22 ga., type B, Grade 33 steel One or more layers, any combination, min. 1.5-inch Prelim. attach EverGuard PVC XK or EverGuard PVC Smooth Drill-Tec XHD with Drill-Tec 2-3/8inch Barbed XHD Plates 6-inch o.c. within 6-inch wide laps spaced 114inch o.c. and sealed with a 1.5-inch heat weld. -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 20 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Vapor Barrier No. (See Note 1) EVERGUARD PVC-50, -60 or -80 APPLICATIONS: (Optional) See Note A C-1. Struct conc. below Base Insulation Layer Type Min. 1-inch EnergyGuard RA Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, C-2. Struct conc. ACFoam III, Min. 2-inch Styrofoam Deckmate Plus FA or Min. 1-inch Foamular 250 (Optional) See Note A Min. 1.5-inch EnergyGuard RA, C-3. Struct conc. below EnergyGuard RN, ACFoam III EVERGUARD PVC SMOOTH OR PVC XK / EVERGUARD #2331 BONDING ADHESIVE: (Optional) See Note A Min. 0.5-inch EnergyGuard Polyiso C-4. Struct conc. below Insulation, EnergyGuard Ultra (Optional) See Note A Min. 1.5-inch EnergyGuard RA, C-5. Struct conc. below EnergyGuard RH or EnergyGuard RN D41 or Matrix™ 307 Premium Asphalt Primer C-6. Struct conc. Min. 1.5-inch EnergyGuard RH & UnderRoof HT High Temperature Leak Barrier D41 or Matrix™ 307 Premium Asphalt Primer C-7. Struct conc. Min. 1.5-inch EnergyGuard RH & UnderRoof 2 PolyesterSurfaced Leak Barrier (Optional) See Note A below Top Insulation Layer Type Attach Attach None N/A EverGuard PVC-50, -60 or -80 / #2331 -325.0 OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -240.0 GAF 2Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC-50, -60 or -80 / #2331 -240.0 OB500 (Optional) Additional layers of base insulation OB500 OB500 (Optional) Additional layer of base insulation OB500 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -37.5 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5 OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime Min. 1.5-inch EnergyGuard RH (Optional) See Note A below (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 C-12. Struct conc. (Optional) See Note A below Min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN OB500 C-13. Struct conc. None Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layer of base insulation LRF-M None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M (Optional) Additional layers of base insulation LRF-M Struct conc. C-9. Struct conc. C-10. Struct conc. C-11. C-14. Struct conc. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 MDP (psf) OB500 (Optional) See Note A below C-8. Roof Cover / Adhesive OB500 OB500 OB500 Min. 0.25-inch Dens Deck Prime Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 OB500 OB500 OB500 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 EverGuard PVC Smooth or PVC XK / #2331 -232.5 -247.5 -232.5 -247.5 -202.5 -202.5 -162.5 -232.5 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 21 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Vapor Barrier Base Insulation Layer Type Attach C-15. Struct conc. None Min. 1.5-inch EnergyGuard RH LRF-M C-16. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M C-17. Struct conc. None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M C-18. Struct conc. (Optional) See Note A below C-19. Struct conc. (Optional) See Note A below C-20. Struct conc. (Optional) See Note A below Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN EVERGUARD PVC XK FLEECEBACK IN HOT ASPHALT: Struct conc. C-21. None Min. 1-inch EnergyGuard RH (primed) EVERGUARD PVC XK FLEECEBACK IN EVERGUARD WB181 BONDING ADHESIVE: Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A Insulation, EnergyGuard Ultra or min. C-22. Struct conc. below 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN D41 or Matrix™ 307 Premium Asphalt Primer C-23. Struct conc. Min. 1.5-inch EnergyGuard RH & UnderRoof HT High Temperature Leak Barrier D41 or Matrix™ 307 Premium Asphalt Primer C-24. Struct conc. Min. 1.5-inch EnergyGuard RH & UnderRoof 2 PolyesterSurfaced Leak Barrier C-25. Struct conc. (Optional) See Note A below Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Min. 1.5-inch EnergyGuard RH Top Insulation Layer Type Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board Roof Cover / Adhesive MDP (psf) LRF-M EverGuard PVC Smooth or PVC XK / #2331 -97.5 LRF-M EverGuard PVC Smooth or PVC XK / #2331 -232.5 LRF-M EverGuard PVC Smooth or PVC XK / #2331 -202.5 Attach GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -232.5 GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -232.5 GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board GAF 2Part EverGuard PVC Smooth or PVC XK / #2331 -202.5 HA (Optional) Additional layers of base insulation HA EverGuard PVC XK Fleeceback / Hot asphalt -490.0 OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / WB181 -90.0 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -37.5 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5 OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 22 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Vapor Barrier C-26. Struct conc. (Optional) See Note A below C-27. Struct conc. None Base Insulation Layer Type Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Attach MDP (psf) OB500 EverGuard PVC XK Fleeceback / WB181 -90.0 LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0 LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0 LRF-M EverGuard PVC XK Fleeceback / WB181 -97.5 None Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M C-29. Struct conc. None Min. 1.5-inch EnergyGuard RH LRF-M Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Roof Cover / Adhesive Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Struct conc. Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. C-30. Struct conc. 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A Insulation, EnergyGuard Ultra or min. C-31. Struct conc. below 1.5-inch EnergyGuard RA, EnergyGuard RH or EnergyGuard RN EVERGUARD PVC XK FLEECEBACK IN LRF ADHESIVE M OR LRF ADHESIVE O: (Optional) See Note A Min. 1-inch EnergyGuard RA, C-32. Struct conc. below EnergyGuard RH, EnergyGuard RN (Optional) See Note A Min. 0.5-inch EnergyGuard Polyiso C-33. Struct conc. below Insulation, EnergyGuard Ultra Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A C-34. Struct conc. Insulation, EnergyGuard Ultra, below EnergyGuard RA, EnergyGuard RH Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A C-35. Struct conc. Insulation, EnergyGuard Ultra, below EnergyGuard RA, EnergyGuard RH (Optional) See Note A (Optional) Min. 1-inch EnergyGuard C-36. Struct conc. below RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A Insulation, EnergyGuard Ultra, C-37. Struct conc. below EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A C-38. Struct conc. Insulation, EnergyGuard Ultra, below EnergyGuard RH, EnergyGuard RN Attach OB500 C-28. (Optional) See Note A below Top Insulation Layer Type Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC XK Fleeceback / WB181 -90.0 GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / WB181 -90.0 OB500 (Optional) Additional layers of base insulation OB500 OB500 (Optional) Additional layers of base insulation OB500 OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c. -37.5 OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. -45.0 OB500 Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c. EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 -60.0 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 23 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Vapor Barrier D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied (Optional) See Note A below C-39. Struct conc. C-40. Struct conc. C-41. Struct conc. None C-42. Struct conc. None C-43. Struct conc. None C-44. Struct conc. None C-45. Struct conc. None C-46. Struct conc. None C-47. Struct conc. D41 or Matrix™ 307 Premium Asphalt Primer & Ruberoid HW Smooth or Ruberoid HW 25 Smooth, torch applied C-48. Struct conc. None C-49. Struct conc. (Optional) See Note A below C-50. Struct conc. (Optional) See Note A below Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Base Insulation Layer Type Top Insulation Layer Type Attach Attach Roof Cover / Adhesive MDP (psf) EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None N/A Min. 1-inch EnergyGuard RH LRF-M (Optional) Additional layers of base insulation LRF-M LRF-M (Optional) Additional layers of base insulation LRF-M LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c. -37.5 LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. -45.0 LRF-M Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 LRF-M (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 LRF-M None N/A GAF 2Part (Optional) Additional layers of base insulation GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime GAF 2Part EverGuard PVC XK Fleeceback / LRF-O, 12-inch o.c. Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -195.0 -45.0 -60.0 -195.0 -60.0 -45.0 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 24 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Vapor Barrier C-51. Struct conc. (Optional) See Note A below C-52. Struct conc. (Optional) See Note A below Base Insulation Layer Type Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN D41 or Matrix™ 307 Premium Asphalt Primer Min. 0.5-inch EnergyGuard Polyiso C-53. Struct conc. & Ruberoid HW Smooth Insulation, EnergyGuard Ultra, or Ruberoid HW 25 EnergyGuard RH, EnergyGuard RN Smooth, torch applied (Optional) See Note A Min. 0.25-inch Dens Deck Prime or C-54. Struct conc. below SECUROCK Gypsum-Fiber Roof Board EVERGUARD PVC XK FLEECEBACK IN GAF 2-PART ROOFING ADHESIVE: (Optional) See Note A Min. 0.5-inch EnergyGuard Polyiso C-55. Struct conc. below Insulation, EnergyGuard Ultra Min. 0.5-inch EnergyGuard Polyiso (Optional) See Note A C-56. Struct conc. Insulation, EnergyGuard Ultra, below EnergyGuard RH, EnergyGuard RN D41 or Matrix™ 307 Premium Asphalt Primer Min. 0.5-inch EnergyGuard Polyiso C-57. Struct conc. & Ruberoid HW Smooth Insulation, EnergyGuard Ultra, or Ruberoid HW 25 EnergyGuard RH, EnergyGuard RN Smooth, torch applied (Optional) See Note A Min. 0.25-inch Dens Deck Prime or C-58. Struct conc. below SECUROCK Gypsum-Fiber Roof Board Min. 0.5-inch EnergyGuard Polyiso C-59. Struct conc. None Insulation, EnergyGuard Ultra Min. 0.5-inch EnergyGuard Polyiso C-60. Struct conc. None Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN D41 or Matrix™ 307 Premium Asphalt Primer Min. 0.5-inch EnergyGuard Polyiso C-61. Struct conc. & Ruberoid HW Smooth Insulation, EnergyGuard Ultra, or Ruberoid HW 25 EnergyGuard RH, EnergyGuard RN Smooth, torch applied Min. 0.25-inch Dens Deck Prime or C-62. Struct conc. None SECUROCK Gypsum-Fiber Roof Board (Optional) See Note A Min. 0.5-inch EnergyGuard Polyiso C-63. Struct conc. below Insulation, EnergyGuard Ultra Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Top Insulation Layer Type Attach Attach Roof Cover / Adhesive MDP (psf) GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch SECUROCK GypsumFiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 GAF 2Part (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 GAF 2Part None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -195.0 OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0 OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 OB500 (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 OB500 None N/A LRF-M (Optional) Additional layers of base insulation LRF-M LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 LRF-M (Optional) Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 LRF-M None N/A (Optional) Additional layers of base insulation GAF 2Part GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter EverGuard PVC XK Fleeceback / GAF 2-Part, spatter EverGuard PVC XK Fleeceback / GAF 2-Part, spatter EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -195.0 -60.0 -195.0 -60.0 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 25 of 39 TABLE 3A: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. C-64. Deck (See Note 1) Struct conc. Vapor Barrier (Optional) See Note A below Base Insulation Layer Type Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN Attach GAF 2Part Top Insulation Layer Type Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Attach GAF 2Part Roof Cover / Adhesive MDP (psf) EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 D41 or Matrix™ 307 Premium Asphalt Primer Min. 0.5-inch EnergyGuard Polyiso GAF 2(Optional) Min. 0.25-inch Dens Deck Prime or GAF 2EverGuard PVC XK Fleeceback C-65. Struct conc. & Ruberoid HW Smooth Insulation, EnergyGuard Ultra, -180.0 Part SECUROCK Gypsum-Fiber Roof Board Part / GAF 2-Part, spatter or Ruberoid HW 25 EnergyGuard RH, EnergyGuard RN Smooth, torch applied (Optional) See Note A Min. 0.25-inch Dens Deck Prime or GAF 2EverGuard PVC XK Fleeceback C-66. Struct conc. None N/A -195.0 below SECUROCK Gypsum-Fiber Roof Board Part / GAF 2-Part, spatter A. The following are options for installation of an optional vapor barrier / temporary roof on the concrete deck prior to insulation placement. If vapor barrier / temp roof is installed, concrete deck shall be primed with Matrix™ 307 Premium Asphalt Primer or ASTM D41 primer prior to its installation. Maximum design pressure (MDP) shall be the lesser of that for the system in Table 3A, and that for the vapor barrier / insulation adhesive noted below. 1. 2. 3. For use with OB500 applied insulation: One or two plies, asphalt-applied GAF base and/or ply sheet: Ruberoid 20 Smooth in Matrix™ 102 SBS Membrane Adhesive in full coverage: Ruberoid Torch Smooth, heat welded: Ruberoid HW 25 Smooth, heat welded: Ruberoid HW Smooth, heat welded: UnderRoof HT High Temperature Leak Barrier, self-adhered: UnderRoof 2 Polyester-Surfaced Leak Barrier, self-adhered: MDP -352.5 psf MDP -202.5 psf MDP -165.0 psf MDP -180.0 psf MDP -232.5 psf MDP -37.5 psf MDP -127.5 psf For use with GAF 2-Part applied insulation: One or two plies, asphalt-applied GAF base ply and/or ply: Optional asphalt-applied GAF base ply, ply or base membrane with asphalt-applied GAF SBS cap membrane: Optional asphalt-applied GAF base ply, ply or base membrane or heat-welded GAF base membrane with heat-welded GAF SBS or APP cap membrane: Optional self-adhering Liberty base membrane with Liberty cap membrane: Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded: For use with GAF LRF-Adhesive M: Ruberoid HW 25 Smooth or Ruberoid HW Smooth, heat-welded: MDP -262.5 psf MDP -270.0 psf MDP -169.0 psf MDP -250.0 psf MDP -180.0 psf MDP -180.0 psf TABLE 3B: CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Roof Deck Roof Cover / Adhesive MDP (psf) C-67. Struct conc. EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 6-inch o.c. -45.0 C-68. Struct conc. primed with Matrix™ 307 Premium Asphalt Primer EverGuard PVC XK Fleeceback / Hot asphalt at 25 lbs/square -502.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 26 of 39 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck (See Note 1) System No. Roof Deck Base Insulation Layer LWIC (See Note 15) Type Coverboard Attach Type Attach Roof Cover / Adhesive MDP (psf) LWC-1. Struct. conc. Min. 200 psi, min. 2inch thick Elastizell Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, ACFoam III, Min. 2-inch Styrofoam Deckmate Plus FA or Min. 1-inch Foamular 250 OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -225.0 LWC-2. Struct. conc. Min. 200 psi, min. 2inch thick Elastizell Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -180.0 LWC-3. Struct. conc. Min. 200 psi, min. 2inch thick Celcore Cellular Concrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -222.5 LWC-4. Struct. conc. Min. 200 psi, min. 2inch thick Mearlcrete Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -240.0 TABLE 4B: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Roof Deck (See Note 1) Structural Deck LWIC (See Note 15) Base Sheet Roof Cover Type Fasteners Attach Base GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail or Trufast FM-290 7-inch o.c. at min. 4inch laps and 7-inch o.c. in two, equally spaced, staggered center rows (Optional) One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 or Ruberoid Mop Plus Smooth in hot asphalt or one or two plies Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch-applied GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Stratavent Nailable Venting Base Sheet, Ruberoid 20 Smooth Drill-Tec Base Sheet Fastener (1.7 in.), Drill-Tec Base Sheet Fastener E (1.7 in.), Drill-Tec Locking Impact Nail or Trufast FM-290 7-inch o.c. at min. 4inch laps and 7-inch o.c. in two, equally spaced, staggered center rows One or two plies Ruberoid 20 Smooth, Ruberoid Mop Smooth, Ruberoid Mop Smooth 1.5 or Ruberoid Mop Plus Smooth in hot asphalt or one or two plies Ruberoid HW 25 Smooth or Ruberoid HW Smooth, torch-applied Cap MDP (psf) HYBRID SYSTEMS: LWC-5. LWC-6. Min. 22 ga., type B, 40 ksi vented steel at max. 6 ft spans Min. 22 ga., type B, 40 ksi vented steel at max. 6 ft spans Min. 340 psi, min. 2-inch thick cellular lightweight insulating concrete. Note: To qualify the LWC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per TAS105 or ANSI/SPRI FX-1 Min. 340 psi, min. 2-inch thick cellular lightweight insulating concrete. Note: To qualify the LWC under this assembly, the selected fastener shall achieve an average withdrawal of 60 lbf or greater when tested per TAS105 or ANSI/SPRI FX-1 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 EverGuard PVC XK Fleeceback in -52.5 hot apshalt EverGuard PVC XK Fleeceback in GAF 2-Part, spatterapplied -52.5 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 27 of 39 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Roof Deck (See Note 1) System No. Roof Cover Min. Compressive Strength (psi) Min. Thick (in) Membrane Adhesive MDP (psf) LWIC (See Note 15) Deck Type LWC-7. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Mearlcrete 290 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5 LWC-8. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Elastizell 290 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5 LWC-9. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Concrecel 290 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5 LWC-10. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -52.5 LWC-11. Structural concrete Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -102.5 LWC-12. Structural concrete Elastizell 220 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -200.0 LWC-13. Structural concrete Mearlcrete 290 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -205.0 LWC-14. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback EverGuard WB181 Bonding Adhesive -225.0 LWC-15. Structural concrete Elastizell 300 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 6-inch o.c. -45.0 LWC-16. Structural concrete Mearlcrete 730 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 6-inch o.c. -45.0 Structural concrete Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback LRF-M, ribbons 4-inch o.c. -92.5 LWC-18. Structural concrete Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback LRF-O, ribbons 4-inch o.c. -112.5 LWC-19. Structural concrete Elastizell 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -210.0 LWC-20. Structural concrete Mearlcrete or Insulcel 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -270.0 LWC-21. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback LRF-M, 4-inch o.c. -225.0 LWC-22. Structural concrete Celcore Cellular Concrete 200 2 EverGuard PVC XK Fleeceback LRF-M or LRF-O, 4-inch o.c. -300.0 LWC-17. Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 28 of 39 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Roof Deck (See Note 1) System No. Roof Cover LWIC (See Note 15) Deck Type Min. Compressive Strength (psi) Min. Thick (in) LWC-23. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5 LWC-24. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Mearlcrete 290 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5 LWC-25. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Elastizell 290 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5 LWC-26. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Concrecel 290 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -52.5 LWC-27. Min. 22 ga., type BV, Grade 33 steel at max. 6 ft spans Elastizell 160 3 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -60.0 LWC-28. Structural concrete Cellular lightweight insulating concrete; Note: To qualify the LWC under this assembly, a Drill-Tec™ Base Sheet Fastener (1.7 in.) or Drill-Tec™ Base Sheet Fastener E (1.7 in.) shall achieve an average withdrawal of 97 lbf or greater when tested per ANSI/SPRI FX-1 or TAS105. 180 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -102.5 LWC-29. Structural concrete Elastizell 220 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -200.0 LWC-30. Structural concrete Mearlcrete 290 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -205.0 LWC-31. Structural concrete Concrecel 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -225.0 LWC-32. Structural concrete Insulcel 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -270.0 LWC-33. Structural concrete Celcore Cellular Concrete 200 2 EverGuard PVC XK Fleeceback GAF 2-Part, spatter -300.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Adhesive MDP (psf) Membrane Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 29 of 39 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Deck (See Note 1) Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) CWF-1. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, ACFoam III OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0 CWF-2. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, ACFoam III, Min. 2-inch Styrofoam Deckmate Plus FA or Min. 1-inch Foamular 250 OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0 CWF-3. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c. -45.0 CWF-4. Min. 2-inch Tectum Plank or Tectum LS Plank (Optional) Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRFM or LRF-O, 12-inch o.c. -45.0 CWF-5. Min. 2-inch Tectum Plank or Tectum LS Plank Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard RH LRF-M (Optional) Additional layers of base insulation LRF-M EverGuard PVC XK Fleeceback / LRFM, 12-inch o.c. -45.0 CWF-6. Min. 2-inch Tectum Plank or Tectum LS Plank or Fibroplank Min. 1.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard RA or ACFoam III GAF 2-Part (Optional) Additional layer of Base Insulation GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5 CWF-7. Min. 2-inch Tectum Plank or Tectum LS Plank or Fibroplank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC Smooth or PVC XK / #2331 -52.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 30 of 39 TABLE 6A: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Deck (See Note 1 & 12) G-1. Existing poured gypsum or gypsum plank Min. 1-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation G-2. Existing poured gypsum or gypsum plank Min. 1-inch EnergyGuard RA OB500 G-3. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, ACFoam III, Min. 2-inch Styrofoam Deckmate Plus FA or Min. 1-inch Foamular 250 G-4. Existing poured gypsum or gypsum plank G-5. Existing poured gypsum or gypsum plank Roof Cover / Adhesive MDP (psf) OB500 EverGuard PVC XK Fleeceback / LRF-M, 6-inch o.c. -45.0 None N/A EverGuard PVC-50, -60 or -80 / #2331 -262.5 OB500 Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -112.5 Min. 1-inch EnergyGuard RH LRF-M None N/A EverGuard PVC Smooth / #2331 -352.5 Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2-Part Min. 0.25-inch Dens Deck or SECUROCK Gypsum-Fiber Roof Board GAF 2-Part EverGuard PVC-50, -60 or -80 / #2331 -240.0 Type Attach Type Attach TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) Base Insulation Layer Type Top Insulation Layer Fasten Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC SMOOTH OR PVC XK APPLICATIONS: G-6. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-7. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-8. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra followed by min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-9. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra followed by min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* G-10. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 2 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 31 of 39 TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) G-11. Existing poured gypsum or gypsum plank Base Insulation Layer Type Top Insulation Layer Roof Cover / Adhesive MDP (psf) OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Fasten Attach Type Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH G-12. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 G-13. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) G-14. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH G-15. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Attach EVERGUARD PVC XK FLEECEBACK APPLICATIONS: G-16. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-17. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-18. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra followed by min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* G-19. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra followed by min. 0.25-inch Dens Deck Prime or SECUROCK GypsumFiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 2 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 32 of 39 TABLE 6B: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (See Note 1) G-20. Existing poured gypsum or gypsum plank G-21. Base Insulation Layer Type Top Insulation Layer Roof Cover / Adhesive MDP (psf) LRF-M EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* 1 per 2.9 ft2 Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* 1 per 2 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2.9 ft2 Optional min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or min. 1.5-inch EnergyGuard RH followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 or LRFM or LRF-O, 12-inch o.c. -45.0* Fasten Attach Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 3.2 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) 1 per 2 ft2 G-22. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) G-23. Existing poured gypsum or gypsum plank Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2inch embedment) G-24. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or EnergyGuard RH G-25. Existing poured gypsum or gypsum plank Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Type Attach Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 33 of 39 TABLE 6C: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer System No. Deck (See Note 1) Base Insulation Layer G-26. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) G-27. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH G-28. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination G-29. Existing poured gypsum or gypsum plank (Optional) One or more layers, any combination Roof Cover / Adhesive MDP (psf) 1 per 2 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) 1 per 2.9 ft2 EverGuard PVC Smooth or PVC XK / #2331 -45.0* Min. 1.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) 1 per 2 ft2 EverGuard PVC XK Fleeceback / WB181 or LRF-M or LRF-O, 12-inch o.c. -45.0* Min. 2-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH Drill-Tec Polymer Gyptec with Drill-Tec 3” Gyptec Plates (Min. 2-inch embedment) 1 per 2.9 ft2 EverGuard PVC XK Fleeceback / WB181 or LRF-M or LRF-O, 12-inch o.c. -45.0* Type Fasteners Attach TABLE 6D: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Roof Deck Roof Cover / Adhesive MDP (psf) G-30. Existing poured gypsum or gypsum plank EverGuard PVC XK Fleeceback / LRF-M, 12-inch o.c. -45.0 G-31. Existing poured gypsum or gypsum plank EverGuard PVC XK Fleeceback / LRF-O, 6-inch o.c. -45.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 34 of 39 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (See Notes 1 & 12) Base Insulation Layer Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC APPLICATIONS: R-1. Existing asphaltic BUR or mineral surfaced cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra, ACFoam III, Min. 2-inch Styrofoam Deckmate Plus FA or Min. 1-inch Foamular 250 R-2. Existing asphaltic BUR or mineral surfaced cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RN, ACFoam III GAF 2Part Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board GAF 2Part EverGuard PVC-50, -60 or -80 / #2331 -240.0 OB500 Min. 0.25-inch Dens Deck or SECUROCK GypsumFiber Roof Board OB500 EverGuard PVC-50, -60 or -80 / #2331 -120.0 EVERGUARD PVC SMOOTH OR EVERGUARD PVC XK APPLICATIONS: R-3. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 None N/A EverGuard PVC Smooth or PVC XK / #2331 -45.0 R-4. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 None N/A EverGuard PVC Smooth or PVC XK / #2331 -225.0 R-5. Existing smooth surfaced BUR / APP modified bitumen or granule surfaced roof cover over struct conc. deck (Optional) Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -97.5 R-6. Existing asphaltic BUR or mineral surfaced cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 (Optional) Additional layers of base insulation OB500 EverGuard PVC Smooth or PVC XK / #2331 -120.0 R-7. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC Smooth or PVC XK / #2331 -225.0 R-8. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -202.5 R-9. Existing asphaltic BUR or mineral surfaced cap sheet Min. 1.5-inch EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC Smooth or PVC XK / #2331 -120.0 R-10. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -45.0 R-11. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -75.0 R-12. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC Smooth or PVC XK / #2331 -225.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 35 of 39 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Base Insulation Layer Substrate (See Notes 1 & 12) Type Top Insulation Layer Attach Type Attach Roof Cover / Adhesive MDP (psf) R-13. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0 R-14. Existing smooth surfaced BUR or granule surfaced roof cover (Optional) Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0 R-15. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC Smooth or PVC XK / #2331 -225.0 R-16. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -75.0 R-17. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC Smooth or PVC XK / #2331 -202.5 EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN WB181 BONDING ADHESIVE: R-18. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 None N/A EverGuard PVC XK Fleeceback / WB181 -90.0 R-19. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / WB181 -90.0 R-20. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / WB181 -90.0 R-21. Existing smooth surfaced BUR / APP modified bitumen or granule surfaced roof cover over struct conc. deck (Optional) Min. 1.5-inch EnergyGuard RH OB500 Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation OB500 EverGuard PVC XK Fleeceback / WB181 -97.5 R-22. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC XK Fleeceback / WB181 -75.0 R-23. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC XK Fleeceback / WB181 -90.0 R-24. Existing smooth surfaced BUR or granule surfaced roof cover (Optional) Min. 1.5-inch EnergyGuard RH LRF-M Min. 0.5-inch EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0 R-25. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 36 of 39 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Substrate (See Notes 1 & 12) R-26. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0 R-27. Existing smooth-surfaced BUR over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -75.0 R-28. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / WB181 -90.0 Type Attach Type Attach Roof Cover / Adhesive MDP (psf) EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN LRF ADHESIVE M OR LRF ADHESIVE O: R-29. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra OB500 None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 R-30. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or ACFoam IV OB500 None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0 R-31. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-M, 12inch o.c. -37.5 R-32. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch Dens Deck Prime OB500 EverGuard PVC XK Fleeceback / LRF-O, 12inch o.c. -45.0 R-33. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 R-34. Existing smooth- or granule-surfaced BUR; smooth- or granule-surfaced SBS modified bitumen or granule-surfaced APP modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 R-35. Existing granule-surfaced BUR, granule-surfaced modified bitumen or smooth-surfaced SBS modified bitumen Min. 1-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra LRF-M None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 R-36. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra or ACFoam IV LRF-M None N/A EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 37 of 39 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer System No. Substrate (See Notes 1 & 12) R-37. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M Min. 0.25-inch Dens Deck Prime R-38. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN LRF-M R-39. Existing smooth- or granule-surfaced BUR, granule-surfaced modified bitumen or smoothsurfaced SBS modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RA, EnergyGuard RH, EnergyGuard RN R-40. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck R-41. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck Roof Cover / Adhesive MDP (psf) LRF-M EverGuard PVC XK Fleeceback / LRF-M, 12inch o.c. -37.5 Min. 0.25-inch Dens Deck Prime LRF-M EverGuard PVC XK Fleeceback / LRF-O, 12inch o.c. -45.0 LRF-M Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -180.0 Type Attach Type Attach EVERGUARD PVC XK FLEECEBACK APPLICATIONS IN GAF 2-PART ROOFING ADHESIVE: R-42. Existing smooth- or granule-surfaced BUR; smooth- or granule-surfaced SBS modified bitumen or granule-surfaced APP modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN OB500 Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 R-43. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN LRF-M Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board LRF-M EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 R-44. Existing smooth- or granule-surfaced BUR or smooth- or granule-surfaced modified bitumen over struct conc. deck (Optional) Min. 0.5-inch EnergyGuard Polyiso Insulation, EnergyGuard Ultra, EnergyGuard RH, EnergyGuard RN GAF 2Part Optional additional layers base insulation followed by min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board GAF 2Part EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -180.0 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 38 of 39 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Substrate (See Note 12) Roof Cover / Adhesive MDP (psf) R-45. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -45.0 R-46. Existing asphaltic granule surfaced roof cover over steel deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 12-inch o.c. -60.0 R-47. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen over steel deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -60.0 R-48. Existing smooth or granule surfaced SBS modified bitumen or existing smooth or granule surfaced APP modified bitumen over structural concrete deck EverGuard PVC XK Fleeceback / LRF-M or LRF-O, 4-inch o.c. -337.5 R-49. Existing asphaltic granule surfaced roof cover over wood, CWF or gypsum deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -45.0 R-50. Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over steel deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -60.0 R-51. Existing smooth or granule surfaced SBS modified bitumen or existing granule surfaced APP modified bitumen over structural concrete deck EverGuard PVC XK Fleeceback / GAF 2-Part, spatter -337.5 Exterior Research and Design, LLC. d/b/a Trinity|ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 Evaluation Report 01506.09.04-R21 for FL3443-R18 Revision 21: 02/12/2016 Appendix 1, Page 39 of 39