RDU-SIC G2

advertisement
RDU-SIC G2
Features
ƒƒ
Replace the 1-wire port with COM port
ƒƒ
Enhanced hardware platform (CPU180Mhz>450Mhz \ Memory 32M->64M \ Linux 2.4->2.6)
ƒƒ
3G modem supported: Same as RDU-A G2
(Huawei E173U,.etc)
ƒƒ
RDU-UA software platform
ƒƒ
Java compatible
ƒƒ
SNMP V3 supported
ƒƒ
MIB export supported
ƒƒ
Access ready for ITS remote monitoring service
platform
ƒƒ
Enhanced storage capacity on log and events
ƒƒ
Batch configuration supported
RDU-SIC G2 equipment compatibility
Equipment name
Equipment type
UPS
ITA 1kVA ~ 3kVA
ITA 5VA, 6kVA, 10kVA
ITA 16kVA ~ 20kVA
ITA 30kVA ~ 40kVA
GXT 3G
APM 150
Liebert APS
GXE
Mini SPM (M90)
Air conditioner
DATAMATE 3000
ATP
PACC
CRV+
SDC2
SPC
Cabinet and others
16A LTS (STS Single)
Water-cooled cabinet (W081322-30/
W081322A-30)
Battery detector BM42
Clever PDU (OEM)
MPS PDU
IRM TH Sensor/4DI
Note: The range of the intelligent equipment that can be connected to the RDU-SIC G2 card is subject to change without
notice
HW
CPU
Freescale IMX287/450MHz
Flash
32MB
Memory
64MB
Ethernet Port (10/100M)
1
1-wire sensor port
0
Serial Port
3
GUI
GUI
RDU-UA
OS
OS
Linux 2.6.35
Authorization code
Yes
Client
IE8 and above, compatible with Chrome, Firefix and so on
Equipment Monitoring
Sampling, configurationb display in sheet format
Yes
UPS management
UPS shutdown
Yes
Server Network Shutdown
Yes
Real-time alarm display and search
Yes
History alarm display and search
Yes
Email notification
Yes
Email notification supports SSL
Yes
2G SMS modem
Yes
3G SMS Modem
Yes
System status notification
Yes
Alarm notification configuration
Yes
Equipment Data Display
Yes
MIB export
Yes
History data display and search in sheet format
Yes
History data display and search in curve diagram format
Yes
System Logo
Yes
Delete data record
Yes
Equipment Management
Yes
Equipment Signal Configuration
Yes
System batch configuration
Yes
RDU-C/SIC Information
Yes
Networking configuration
Yes
DNS support
Yes
RDU V1 Protocal support
Yes
RDU V2 Protocal support(Internet Communication)
Yes
SNMP V1/V2c support
Yes
SNMP V3 support
Yes
ITS remote service readiness
Yes
SNMP Trap
Yes
User management
Yes
Date/Time collation
Yes
Restore to default setting
Yes
Site information configuration
Yes
System upgrade
Yes
Title (UI) configuration
Yes
Alarm Management
Data Management
SW
Configuration Management
System Configuration
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all
liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
Emerson Network Power and Liebert® are trademarks of Emerson Electric Co. or one of its affiliated companies. All other names and logos referred to are trade
names, trademarks, or registered trademarks of their respective owners. ©2016 Emerson Electric Co. AP16ENP-RDU-SICG2 -DS
Marketing.AP@emerson.com
www.EmersonNetworkPower.Asia
Download