More availability and reliability due to cost-saving switchgear modernization Electrical Solutions Instrumentation, Controls & Electrical SPPA-E3000 Switchgear modernization upgrades existing switchgear installations to state-of-the-art technology, increases safety and operational efficiency and integrates the switchgear into the control system. This solution is suitable for air-insulated medium-voltage switchgear types from all manufacturers. Your Benefits ■ Increased availability and the security of supply through usage of newer state-of-the-art components ■ Low investment costs thanks to retaining of existing switchgear ■ Enhancement of the personnel and operational safety via the use of components which meet the latest standards and regulations ■ Full integration in SPPA-T3000 The Task Throughout the entire asset life-cycle, the operating conditions and the requirements of the electrical equipment are changing, e. g. after a life-time extension, a turbine upgrade, or if the availability of spare parts is no longer ensured due to obsolete components. However, the switchgear must still be capable of being reliably switched on and off at any time by either the user or the system. But, this does not necessarily lead to a need for renewal of the complete switchgear. Often it may be sufficient to change only the protection systems and switching devices and not the whole switchgear itself. Our Solution is a turnkey solution which contains all components and services for upgrading the medium voltage switchgear to the latest technology and the most economical standard as well as seamlessly integrating the switchgear into our distributed control system SPPA-T3000. The solution comprises: ■ Vacuum circuit-breaker, withdrawable units ■ Digital protection devices ■ Compliance with current requirements for personnel safety ■ Connection of the new components to the existing interfaces ■ Communication interface for the connection to the distributed control system Modern vacuum circuit-breakers are far less independent from the environment than older switching devices which are based on other switching principles. Vacuum circuit-breakers can be integrated into the existing switchgears and lead to higher availability – with derably lower investment costs compared to a complete exchange of a medium-voltage switchgear. As there is no need for modifications concerning the existing housing of the switch-gear and the building, this kind of modernization causes only a short interruption of operation of the switchgear. Expenses for approval procedures can be saved, too. Investment costs can be thus reduced to a minimum. Due to the usage of the modern digital protection devices of the SIPROTEC family, the highest reliability of power supply and operational safety is ensured. Our services comprises: ■ On-site inventory ■ Design and configuration of the components based on local conditions and requirements ■ Removal of old components and installation of switchgear and protection devices of the latest generation ■ Commissioning and inspection on site ■ Complete documentation ■ Best-in-class project management Modern vacuum circuit-breakers are suitable for all existing air-insulated medium voltage switchgear types. Answers for energy. Published by and copyright © 2013: Siemens AG, Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany For more information contact sppa-e3000.energy@siemens.com www.siemens.com/energy/sppa-e3000 Siemens Energy, Inc. Instrumentation, Controls, & Electrical 1345 Ridgeland Parkway, Suite 116 Alpharetta, GA 30004, USA E308_FS_SwgMod_e_V1-0 Order no. E50001-G230-A357-X-4A00 Printed in Germany Dispo 05401, c4bs-Nr. 7465 Printed on elementary chlorine-free bleached paper. Unrestricted AL:N ECCN:N All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.