MergePoint® 52xx Service Processor Manager Firmware Release Notes V 4.3.0.07 Dec 08, 2008 This document includes: 1. Instructions for upgrading 2. Features and enhancements 3. Constraints and conditions ================================================================ 1. Instructions for upgrading ================================================================ Please refer to the MergePoint service processor (SP) manager installer/user guide for more information on how to upgrade the MergePoint service processor manager to version 4.3.0.07. ================================================================ 2. Features and enhancements ================================================================ The following SPs are supported in this release: 1 IPMI 1.5 2 IPMI 2.0 3 IBM® RSA II 4 IBM BladeCenter® 5 DELL® DRAC 3 6 DELL DRAC 4 7 DELL DRAC 5 8 DELL 10G 9 DELL BladeCenter DRAC/MC 10 HP® IPMI 11 HP iLo 12 HP iLo2 13 HP BladeSystem 14 SUN® iLom 15 SUN Alom 16 Fujitsu Siemens iRMC 17 Fujitsu Siemens iRMC S2 18 Sun eLOM We have tested every SP type above. For each type of SP, we have tested at least one firmware version. Here is the firmware list: Unit Type Firmware Bios DELL 1850 1.4 A04 DELL 2850 1.4 A04 DELL 2850 1.5 A05 IBM X346 1.012 1.11 IBM X346 1.03 1.02 IBM X346 1.16 1.14 DELL 1855 Blade server 1.1 A04 Intel 7210 2.4 AMIBIOS 6.00 DELL 1950 1.0.0 1.0.1 DELL 1950 1.17 1.1.0 HP IPMI HP Proliant® DL145 1.23 2.09 HP iLO HP Proliant DL320 1.75 D18 HP Proliant DL320 1.64 D18 HP Proliant DL360 1.82 P54 HP Proliant DL320 1.84 D18 HP Proliant DL 360 1.91 P54 IPMI 1.5 IPMI 2.0 HP iLO2 ® HP Proliant DL320G4 1.20 1.27 1.29 1.40 HP BladeSystem HP BladeSystem® c7000 2.04 DRAC III DELL 750 with DracIII 3.2 A02 DRAC IV DELL 1850 with DracIV 1.23 A02 1 DRAC V ® PowerEdge 2900 with Drac V DELL 1950 with DracV DRAC/MC DELL 1855 BMC 0.21 Drac 1.0 BMC 1.14 Drac 1.0 1.5.0 0.2.9 1.1.0 DELL 10G RSA II r805v 1.44 IBM x346 with RSA II Slimline ® RSA II ILOM Sun iLOM KPEP25A KPEP26A KPEP27A 1.0.117445512 KPEP30A 2.0.2.1 ALOM Sun ALOM 1.54 1.60 IBM BladeCenter® FSC IBM BladeCenter E ® Fujitsu PRIMERGY RX100 S4 BPET34E(AMM) 1.60A 4.06 Rev. 1.04.2532 1.70A ELOM iRMC S2 Sun eLOM ® Fujitsu PRIMERGY RX200 S4 3.15 S39_3D08 3.32A 4.06 Rev. 1.06.2671 Browser session / Auto login / vKVM supports list: Type Browser Session○ 1 IPMI1.5 Yes○ 2 IPMI2.0 Yes○ 2 ALOM Yes○ 2 DRAC 3○ 3 Yes Autologin Yes KVM VM KVM/VM Integrated Tested Machine Type Firmware ® Yes PowerEdge 750 3.20 (Build 10.25) 1.33 (Build 08.04) DRAC 4○ 4 Yes Yes ® Yes PowerEdge 1850 1.35 (Build 09.27) 1.60 (Build 10.04) DRAC 5○ 4 Yes Yes ® Yes PowerEdge 1950 1.0 (06.05.12) 1.33 (08.03.10) 1.75 ILO Yes Yes Yes 1.64 Yes 1.82 1.91 1.20 ILO2○ 5 Yes Yes Yes Yes Yes (IE) (IE) 1.24 1.35 1.43 1.50 ELOM Yes Yes Yes Yes Yes S39 3.15 BuildID: KPEP25A KPEP26A IBM Yes Yes Yes Yes Yes KPEP27A X346 KPEP30A RSAII/SLIM○ 6 A3EP20A GFEP30C GGEP32A ® iRMC iRMC S2 IBM BaldeCenter○ 6 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes PRIMERGY S4 ® PRIMERGY S4 RX100 1.60A 1.70A RX200 3.32A BPET26H Yes Yes Yes Yes Yes 86773RC BPET34E BPET34G Yes* IBM Blade○ 7 DRAC/MC○ 8 Yes* Yes* Dell Modular Server 1.5.0 (Build 10.01) Enclosure DRAC/MC Blade HP BladeSystem ○ 9 Yes* Yes* Yes* HPBladeSystem c7000 Yes* HP Blade Yes* ® 2.04 2.21 Yes* 1.0.117440512 ILOM⑩ Yes Yes Yes Yes Yes ® Sun Fire X4100 1.18 2.0.2.1 2.0.2.6 Yes* indicates that you can read the notes below for more details. Notes: 1. A browser session is for pure port forwarding usage. The web interfaces of some SPs might work abnormally in this mode no matter what kind of port forwarding program you use. 2. IPMI1.5, IPMI2.0 or ALOM has no web management interface itself by default. But it can be integrated with a web interface. In this case, when you customize an SP profile for the IPMI SP and set the web port and web scheme, you are able to use ―Browser session‖. 3. For web browsers in some particular OS (i.e. Linux), if the Java applet in the web browser has no privilege to listen on Port 443 of local IP address (127.*.*.*), the Browser session, Autologin or vKVM won‘t work. It is because the Java applet in the web page of Dell DRAC3 uses the hard-coded port 443 to communicate, but DirectCommand applets of the MergePoint appliance can‘t redirect the communication between the web client and DRAC3 via port 443 due to the privileges. 4. When the maximum number of sessions in DRAC4 or DRAC5 has been reached, the Autologin or KVM fails. You need to reset the firmware of the SP via Telnet or SSH. The command for resetting the SP firmware: racadm racreset 5. The iLO2 KVM runs with ActiveX in an IE browser and with an applet in another browser (e.g. Firefox). The KVM with ActiveX integrates Virtual Media, while KVM with applet does not. iLO remote console (vKVM) does not support multi-session in MS IE via DirectCommand. 6. IBM BladeCenter or RSAII does not support Autologin or vKVM with the firmware version 1.4 or later. If IBM Bladecenter or RSAII leads to a blank page or an error page, you need to reset its SP firmware via Telnet. The command for reset the RSAII: resetsp The command for reset the IBM BladeCenter: env –T system:mm[x] reset 7. The KVM and vMedia function of IBM Blade is integrated with the KVM/vMedia of the IBM BladeCenter KVM/vMedia so you can access each blade through the KVM applet of the BladeCenter. 8. You can visit DRAC/MC‘s digital KVM/vMedia for a blade through ―Browser session‖ ONLY IF the client can communicate with the digital KVM‘s IP directly. 9. You can visit KVM/vMedia of an HP Blade through the HP BladeCenter ―Browser session‖ or ―Autologin‖ interface ONLY IF the client can communicate with the Blade‘s IP directly. An HP Blade can‘t be accessed directly from the HP OA via DirectCommand. So if you want to visit the HP Blade via BladeCenter, you need to add every blade as an SP, and then you are able to visit the SP‘s vKVM. 10. The ILOM‘s KVM/VM applet needs the username and password to be entered manually. The following features are added or bugs are fixed in this release: 1. Added system session status page For each managed service processor, there is a System Session web page showing its session status. 2. Connection test for DirectCommand The connection test for DirectCommand tells the user why the DirectCommand operation failed. This feature saves the time and effort of troubleshooting the problem. 3. Supported setup wizard for deployment The setup wizard tells the user where to start. This lets the user spend less time on configuration and deployment. The wizard configuration can also be saved to a file and applied to another appliance. 4. Supported default IP address If the MergePoint appliance failsto obtain an IP address from the DHCP server, the default IP address will be used instead. 5. Supported new service processor: Sun eLOM 6. Supported new service processor: Fujitsu Siemens iRMC S2 7. Improved license page The improved license web page shows not only how many licenses are used, but also how many licenses are available. 8. Solved the problem of abnormal exiting of SoL session The problem of abnormal exiting of the SoL session when the user types ‗Ctrl+C‘ is fixed. 9. Changed default root password from „avocent‟ to „Syndey‟ 10. Changed menu system for console application for MergePoint 5200 appliance and MergePoint 5300 appliance 11. Supported the distinguishing between DELL DRAC3 and DELL DRAC4 in Discovery 12. Supported the distinguishing between HP iLO and HP iLO2 in Discovery 13. Added support for Sun iLOM in Discovery Discovery can show iLOM as its real type. The previous versions of Discovery can only show it as IPMI. 14. Fixed the “Cannot start DHCP service when Domain Name is empty” bug. 15. Fixed the Discovery and Manage DELL DRAC3 ERA (Embedded RAC Access Controller) bug. 16. Added safe shutdown for the appliance, and enhanced file system Added safe shutdown function in the appliance. The user can safely turn off the appliance with it. In addition, Ext3 is used instead of Ext2. If the file system of the appliance is corrupt, it will try to fix the file system first. If it is not recoverable, then the appliance will run with factory default settings. 17. Improved the performance of DirectCommand The time used to setup a DirectCommand is decreased. It‘s faster to connect DirectCommand. 18. Showed actual DSView user in the active session for sessions created from DSView 19. Supported SuperMicro IPMI 2.0 card. 20. Recorded accounting Logs for both starting and stopping system sessions. 21. Support to show HP iLo/iLo2 IML (iLo Management Log). ================================================================ 3. Constraints and Conditions ================================================================ This release includes the following constraints or conditions: 1. Usernames under User Configuration must be all in lowercase letters. 2. BMC Provisioning can only be configured on the secondary Ethernet Interface (eth1). 3. We support alias for every SP. Do not use special characters in the alias. Only the following characters are allowed: ―0—9‖, ―a—z‖, ―A—Z‖ and ―-―. 4. Power outage during the upgrading process is not recoverable. 5. Not allowed to use special characters in the SP‘s password. We do not support the characters like >‘, ‗<‘, ―‘‖, ―‖‖,‖&‖ or ―|‖. 6. RSAII SP sometimes leads to a blank page in web browser when it‘s processing two or more Web/vKVM sessions simultaneously. This is not a defect of MergePoint appliance and the DirectCommand vKVM session of RSAII will display an ―SP unavailable‖ message instead of a blank page. To solve this problem, reset the RSA II SP firmware and restart the sessions. . A case has been opened with IBM for this issue.