s www.siemens.com/energy High Voltage Disconnectors High quality and reliability delivered. Answers for energy. High-Voltage Disconnectors available up to 800kV Years of experience in high-voltage switching technology go into the design and production of the disconnectors that set an international trend. Customers know Siemens as a powerful partner – a supplier of attractive products and solutions at competitive prices with high quality standard. We comply with our customer’s demand for reliability, safety and costeffectiveness and serve them throughout the world. Irrespective of your application our disconnectors provide the best solution for your requirements every time. In the modern period, the switchyards are going for unmanned stations and with the advent of digital relays, the system is totally computerized and all actions are being carried out away from the switchyard through remote operation control, SCADA systems etc. Any failure in operation on a command or maloperation can create disastrous consequences like power loss, loss of equipment or outages triggering even the grid failure. Siemens Ltd. has an integrated facility for design, testing and manufacturing of disconnectors at Hyderabad. Largest of its kind in India, this plant, manufacturers center break, double break, pantograph and knee type disconnectors. The products range from 36kV upto 800kV for various current ratings from 630A to 3150A* as well as associated earth switches and drive mechanisms. • Expertise in manufacturing disconnectors for varied climatic conditions. • Suggestions on possible interchangeability of components/modifications at design stage itself to optimize the resultant performance. • Accessories like insulators, support structure and terminal connectors can also be supplied as per the customers requirements. • Highly experienced service team for on-site supervision of erection, commissioning and testing. The disconnectors are supplied throughout India covering almost all the switchyards/substations, power stations, paper, sugar, cement, and petrochemical Industries etc. 2 Under these circumstances, this would call for a very reliable & quality conscious product in disconnectors. Product Portfolio Horizontal Double Break Disconnector Double Break Dicconnector can be installed in locations, which have minimal overhead clearance, as blades swing open to the side rather than lifting upwards. Double break disconnectors are normally supplied with earth or without earth switch based on the requirement and they can be either with mechanical gang or with electrical gang operation in order to ensure the smooth operation of all the three poles simultaneoulsy.They are excellent for installations, which have large amount of fault current due to reverse loop contact design. The design of two breaks per phase in series provides much greater line charging or magnetizing current interrupting capability with standard arcing horns. Special Features in our Double Break Isolators: Successfully type tested design meeting the requirements of IEC 62271-102. Successfully tested for short circuit level of 40kA, 50kA and 63kA. Confirming to mechanical endurance of class M2 as per IEC requirements. Horizontal Centre Break Disconnector Centre Break Disconnector can be installed in locations, which have minimal overhead clearance, as blades swing open to the side rather than lifting upwards. An economic advantage of using Centre Break Disconnector is that it requires only six insulators per Disconnector versus nine insulators required for Double End Break Disconnector. Centre break disconnectors are normally supplied with earth or without earth switch based on the requirement and they can be either with mechanical gang or with electrical gang operation in order to ensure the smooth operation of all the three poles simultaneoulsy. Special Features in our Centre Break Isolators: Successfully type tested design meeting the requirements of IEC 62271-102. Successfully tested for Short circuit level of 40kA, 50kA. Confirming to mechanical endurance of class M2 as per IEC requirements. 3 Pantograph Disconnector Pantograph Disconnectors can be installed in locations where coupling of buses/current transfer are required at two different heights. Current transfer will take place from the top-level bus to the bottom level bus through this type of disconnector. Pantograph disconnectors are normally supplied with one earth switch and without earth switch based on the requirement and they are usually electrically gang operated in order to ensure smooth opeartion of all the three poles simultaneously. Special Features in our Pantograph Isolators: Successfully type tested design meeting the requirements of IEC 62271-102. Successfully tested for Short circuit level of 40kA. Confirming to mechanical endurance of class M2 as per IEC requirements. Horizontal Knee Type Disconnector A particular advantage of using Horizontal knee type disconnector is reduced vertical dimension and these disconnectors can be used for any conventional application. The reliable and safe performance of our disconnector is ensured through silver plated contacts, a special mechanism to achieve the high contact pressure and 4 completely free rotating unit bearings. Our disconnectors can withstand short circuit current rating upto 50kA/1sec and the applicable standard is IEC 62271-102. Note: Further information will be provided on specific request from customer Operating Mechanisms Siemens Disconnectors come with two types of operating mechanism depending on the customer’s requirement Motor Operating Mechanism Snap action auxiliary switches with silver-plated contacts for customer’s use. Motor coupled with a reduction worm gear to increase the output torque. Provision for padlock. Electrical interlock between breaker and disconnector. Motor rated for 415Volts, 3 phase AC or 220V/110V DC to meet the customers’ requirement. Robust mechanical interlock between disconnector and earth switch. Local/remote control facility. Manual Operating Mechanism Single phase preventer and overload protection device. Hand lever operated or through reduction gear depending on customer’s requirement. Pole discrepancy relay in case of individual pole operation. Electro-Mechanical interlock. Local manual operation in case of emergency operation. Provision for padlock. Snap action for auxiliary contacts for customer’s use. 5 Product Range & Technical Data Horizontal Double Break Disconnector Technical Particulars Unit Rated voltage (kV) [kV] 36 72.5 123 145 245 420 Rated frequency [Hz] 50 50 50 50 50 50 Rated current [A] 3150 3150 3150 3150 3150 3150* Rated short circuit withstand value [kA] 25 40 40 40/50 40/50 40/50/63 S 3 3 3 3/1 3/1 3/1/1 Rated PF withstand voltage across isolating distance [kVr] 80 160 265 315 530 610 Rated PF withstand voltage between live terminals [kVr] 70 140 230 275 460 520 [kVp] 195 375 630 750 1200 1425 [kVp] 170 325 550 650 1050 1665 [kVp] - - - - - 1245 [kVp] - - - - - 1050 Rated short circuit duration Rated Values and ground Lightning Impulse withstand across Isolating distance Lightning Impulse withstand between live terminals and ground Switching Impulse withstand across Isolating distance Switching Impulse withstand across between live terminals and ground Horizontal Centre Break Disconnector Technical Particulars Unit Rated voltage (kV) [kV] 36 72.5 123 145 245 420 Rated frequency [Hz] 50 50 50 50 50 50 Rated current [A] 3150 3150 3150 3150 3150 3150* Rated short circuit withstand value [kA] 25 40 40 40 40 40/50 S 3 3 3 3 3 3/1 Rated PF withstand voltage across isolating distance [kVr] 80 160 265 315 530 610 Rated PF withstand voltage between live terminals [kVr] 70 140 230 275 460 520 [kVp] 195 375 630 750 1200 1425 [kVp] 170 325 550 650 1050 1665 [kVp] - - - - - 1245 [kVp] - - - - - 1050 Rated short circuit duration Rated Values and ground Lightning Impulse withstand across Isolating distance Lightning Impulse withstand between live terminals and ground Switching Impulse withstand across Isolating distance Switching Impulse withstand across between live terminals and ground 6 Pantograph Disconnector Technical Particulars Unit Rated voltage (kV) [kV] - - - - 245 420 Rated frequency [Hz] - - - - 50 50 Rated current [A] - - - - 3150 3150* Rated short circuit withstand value [kA] - - - - 40 40 S - - - - 3 3 Rated PF withstand voltage across isolating distance [kVr] - - - - 530 610 Rated PF withstand voltage between live terminals [kVr] - - - - 460 520 [kVp] - - - - 1200 1425 [kVp] - - - - 1050 1665 [kVp] - - - - - 1245 [kVp] - - - - - 1050 Rated short circuit duration Rated Values and ground Lightning Impulse withstand across Isolating distance Lightning Impulse withstand between live terminals and ground Switching Impulse withstand across Isolating distance Switching Impulse withstand across between live terminals and ground Horizontal Knee Type Disconnector Technical Particulars Unit Rated voltage (kV) [kV] - - - - - 800 Rated frequency [Hz] - - - - - 50 Rated current [A] - - - - - 3150* Rated short circuit withstand value [kA] - - - - - 50 S - - - - - 1 Rated PF withstand voltage across isolating distance [kVr] - - - - - 1150 Rated PF withstand voltage between live terminals [kVr] - - - - - 830 [kVp] - - - - - 2100(+455) [kVp] - - - - - 2100 [kVp] - - - - - 1175(+650) [kVp] - - - - - 1550 Rated short circuit duration Rated Values and ground Lightning Impulse withstand across Isolating distance Lightning Impulse withstand between live terminals and ground Switching Impulse withstand across Isolating distance Switching Impulse withstand across between live terminals and ground * The rating of disconnector for 4500A is available against specific request. 7 A worldwide 24 hours service is available, which immediately sends out service personnel and/or delivers spare parts as needed. Customer Support Center: Toll free Phone no. in India: 1800 2667 480 Email: energysupport.in@siemens.com XX-XX-XXX-XXX Siemens Ltd. Plot No 89 and 90, IDA -Gandhinagar, Balanagar(Post), Hyderabad-500037, Andhra Pradesh,India Fax:+91 40 23079992 www.siemens.com/energy Product upgradation is a continuous process. Hence, data in this catalog is subject to change without prior notice. For the latest information, please get in touch with our Sales Offices.