Energy

advertisement
Energy
Data Record for Used Industrial Steam Turbines / Turbosets
Turbine
Machine No.:
Original Equipment Manufacturer (OEM): Siemens
Year of manufacture: 1971
Turbine model: G500-2
Design output (MW)
[at best turbine efficiency]: 12.6
Maximum output (MW): 12.6
Steam consumption at design output (kg/kWh):
1)
_
Steam consumption at max. output (kg/kWh):
Max. main steam temperature (°C) : 490
Main steam temperature (°C)1): 490
Main steam pressure (bar g)1): 80
Main steam flow (t/h)1): 80
Exhaust steam temperature (°C)1): 165
Exhaust steam flow (t/h)1): 80
Exhaust steam pressure (bar): 4.5
Extraction pressure (bar g)2): -
Extraction flow (t/h)2): -
Speed (rpm): 6,500
Allowable frequency range (Hz): 50
Direction of rotation:
Exhaust steam nozzle (downward, upward, right, left or axial): downward
Non-drive end of turbine (HP/LP end): LP end
Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): no
In case of package, is integral lube oil system provided? (yes/no): or extract from Operating Manual
Load points
1
2
3
Main steam parameters
Main steam flow (t/h)
Extraction pressure (bar)
Extraction flow (t/h)
Exh. steam pressure (bar)
Exh. steam temp. (°C)1)
Terminal output (kW)
Turbine condition Ok
Last minor overhaul:
Last major overhaul: 100,000 h Rev.
Operating hours: 141,222
Date of turbine shutdown and preservation details: July 2012, connected to dryer
Expected to be available as from: as of now
1) in accordance with turbine design
2) where applicable
Siemens AG
Energy Sector; Management: Michael Süss
Energy Service Division; Management: Randy Zwirn
Oil & Gas and Industrial Applications Services; Management: Willibald Meixner
Frankenstr. 70-80
90461 Nuremberg
Germany
Phone: +49 (911) 4130 0
Fax: +49 (911) 4130 440
Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Peter Löscher, Chairman, President and Chief Executive
Officer; Roland Busch, Brigitte Ederer, Klaus Helmrich, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, Peter Y. Solmssen, Michael Süss
Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300; Munich, HRB 6684
WEEE Reg. No. DE 23691322
SCF 04/2011 V08.12
Page 1 of 3
Energy
Are spare parts available? If yes, which ones?
-
Turbine control and protection system:
Original Equipment Manufacturer (OEM):
Hydraulic or electronic: hydraulic
Overspeed protection system (hydraulic [bolt]/electronic):
Axial shaft position monitoring system (hydraulic [nozzle]/electronic):
_
Vibration monitoring system (yes/no):
Actuators for control and stop valve(s) (HP/LP hydraulic system):
Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth):
Electrohydraulic converter installed (yes/no):
Condenser: no
Original Equipment Manufacturer (OEM):
Condenser model:
Condensing capacity (t/h):
Condenser pressure (bar):
3
Cooling water flow (m /h):
Cooling water velocity (m/s):
Cooling water inlet temperature (°C):
Thermal capacity (MW):
Supply lines:
Complete operating documentation available (yes/no): no
Complete machine file available (yes/no): no
Is the driven machine also available for purchase (yes/no): yes, generator
SCF 04/2011 V08.12
Page 2 of 3
Energy
_
Driven generator
Machine No.:
Original Equipment Manufacturer (OEM): Siemens
Rating (MVA): 16
Generator type (cooling system):
Generator model: 1DT440-3DE02-Z
Voltage (kV): 6,300
Frequency (Hz): 50
Current (A): 1,466
Power factor (cos phi): 0.8
Speed (rpm): 1,500
Design:
Insulation class: F
Type of enclosure:
Cooling water inlet temperature (°C):
Cooling water flow (m3/h):
Compound excitation (… V - … A):
Generator condition Ok
Last minor overhaul:
Last major overhaul:
Operating hours:
Date of turbine shutdown and preservation details: July 2012, no
Expected to be available as from: as of now
Gear unit:
Original Equipment Manufacturer (OEM): Siemens
Gear unit model:
Rating (HP)
Speed (rpm): 6,500 / 1,500
Complete scope of supply available for purchase:

Turbine

Gear unit

Generator

Lube oil module

Control hydraulic

Further auxiliaries



Size (footprint) / dimensions:
Siehe Zeichnung
Please provide photographs of the turboset / turbine separately in electronic form.
SCF 04/2011 V08.12
Page 3 of 3