Energy Data Record for Used Industrial Steam Turbines / Turbosets Turbine Machine No.: Original Equip. Manufacturer (OEM): KKK Year of manufacture: 1993 Turbine model: CFR 3G5/CF8 GS Design output (MW) [at best turbine efficiency]: 1.5 Maximum output (MW): 1.5 Steam consumption at design output (kg/kWh): 6 Steam consumption at max. output (kg/kWh): 6 1) _ Max. main steam temperature (°C) : 460 Main steam temperature (°C)1): 450 Main steam pressure (bar g)1): 24 Main steam flow (t/h)1): 10 Exhaust steam temperature (°C)1): 65 Exhaust steam flow (t/h)1): 9.5 Exhaust steam pressure (bar): -0.8 Extraction pressure (bar g)2): 0.8 Extraction flow (t/h)2): 0.5 - 8 Speed (rpm): 1,500 Allowable frequency range (Hz): unknown Direction of rotation: right Exhaust steam nozzle (downward, upward, right, left or axial): downward Non-drive end of turbine (HP/LP end): curved-tooth coupling Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): HP turbine – gear – generator – gear – LP turbine In case of package, is integral lube oil system provided? (yes/no): yes or extract from Operating Manual Load points Main steam parameters 1 3 24 bar/410 Grad C Main steam flow (t/h) 8.5 Extraction pressure (bar) 0.8 Extraction flow (t/h) 2.5 Exh. steam pressure (bar) -0.8 Exh. steam temp. (°C)1) 2 70 after motive steam condenser Terminal output (kW) 1,200 Turbine condition Last minor overhaul: - Last major overhaul: 2005 Operating hours: ca. 75,000 Date of turbine shutdown and preservation details: yes, 2008 Expected to be available as from: as of now 1) in accordance with turbine design 2) where applicable Siemens AG Energy Sector; Management: Michael Süss Energy Service Division; Management: Randy Zwirn Oil & Gas and Industrial Applications Services; Management: Willibald Meixner Frankenstr. 70-80 90461 Nuremberg Germany Phone: +49 (911) 4130 0 Fax: +49 (911) 4130 440 Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Peter Löscher, Chairman, President and Chief Executive Officer; Roland Busch, Brigitte Ederer, Klaus Helmrich, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, Peter Y. Solmssen, Michael Süss Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300; Munich, HRB 6684 WEEE Reg. No. DE 23691322 SCF 04/2011 V08.12 Page 1 of 3 Energy Are spare parts available? If yes, which ones? Complete second steam turbine unit Turbine control and protection system Original Equipment Manufacturer (OEM): Siemens Hydraulic or electronic: electronic Overspeed protection system (hydraulic [bolt]/electronic): electronic and hydraulic Axial shaft position monitoring system (hydraulic [nozzle]/electronic): electronic _ Vibration monitoring system (yes/no): no Actuators for control and stop valve(s) (HP/LP hydraulic system): no Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): yes / unknown Electrohydraulic converter installed (yes/no): yes Condenser: Original Equipment Manufacturer (OEM): Serck Como Condenser model: AA 43 CD 28/40 H 5K 120-2 Condensing capacity (t/h): 9.5 Condenser pressure (bar): -0.8 3 Cooling water flow (m /h): 360 Cooling water velocity (m/s): 1.97 Cooling water inlet temperature (°C): 27 Thermal capacity (MW): 6.384 Supply lines: NW 350 Complete operating documentation available (yes/no): yes Complete machine file available (yes/no): no Is the driven machine also available for purchase (yes/no): yes (Generator) SCF 04/2011 V08.12 Page 2 of 3 Energy _ Driven generator Machine No.: Original Equipment Manufacturer (OEM): Rating (MVA): Generator type (cooling system): Generator model: Voltage (kV): Frequency (Hz): Current (A): Power factor (cos phi): Speed (rpm): Design: e.g. B3 Insulation class: Type of enclosure: Cooling water inlet temperature (°C): Cooling water flow (m3/h): Compound excitation (… V - … A): Gear unit: Original Equipment Manufacturer (OEM): Gear unit model: Rating (HP) Speed (rpm): Complete scope of supply available for purchase: Size (footprint) / dimensions: Please provide photographs of the turboset / turbine separately in electronic form. SCF 04/2011 V08.12 Page 3 of 3