Energy

advertisement
Energy
Data Record for Used Industrial Steam Turbines / Turbosets
Turbine
Machine No.:
Original Equip. Manufacturer (OEM): KKK
Year of manufacture: 1993
Turbine model: CFR 3G5/CF8 GS
Design output (MW)
[at best turbine efficiency]: 1.5
Maximum output (MW): 1.5
Steam consumption at design output (kg/kWh): 6
Steam consumption at max. output (kg/kWh): 6
1)
_
Max. main steam temperature (°C) : 460
Main steam temperature (°C)1): 450
Main steam pressure (bar g)1): 24
Main steam flow (t/h)1): 10
Exhaust steam temperature (°C)1): 65
Exhaust steam flow (t/h)1): 9.5
Exhaust steam pressure (bar): -0.8
Extraction pressure (bar g)2): 0.8
Extraction flow (t/h)2): 0.5 - 8
Speed (rpm): 1,500
Allowable frequency range (Hz): unknown
Direction of rotation: right
Exhaust steam nozzle (downward, upward, right, left or axial): downward
Non-drive end of turbine (HP/LP end): curved-tooth coupling
Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor):
HP turbine – gear – generator – gear – LP turbine
In case of package, is integral lube oil system provided? (yes/no): yes
or extract from Operating Manual
Load points
Main steam parameters
1
3
24 bar/410 Grad C
Main steam flow (t/h)
8.5
Extraction pressure (bar)
0.8
Extraction flow (t/h)
2.5
Exh. steam pressure (bar)
-0.8
Exh. steam temp. (°C)1)
2
70 after motive steam
condenser
Terminal output (kW)
1,200
Turbine condition
Last minor overhaul: -
Last major overhaul: 2005
Operating hours: ca. 75,000
Date of turbine shutdown and preservation details: yes, 2008
Expected to be available as from: as of now
1) in accordance with turbine design
2) where applicable
Siemens AG
Energy Sector; Management: Michael Süss
Energy Service Division; Management: Randy Zwirn
Oil & Gas and Industrial Applications Services; Management: Willibald Meixner
Frankenstr. 70-80
90461 Nuremberg
Germany
Phone: +49 (911) 4130 0
Fax: +49 (911) 4130 440
Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Peter Löscher, Chairman, President and Chief Executive
Officer; Roland Busch, Brigitte Ederer, Klaus Helmrich, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, Peter Y. Solmssen, Michael Süss
Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300; Munich, HRB 6684
WEEE Reg. No. DE 23691322
SCF 04/2011 V08.12
Page 1 of 3
Energy
Are spare parts available? If yes, which ones?
Complete second steam turbine unit
Turbine control and protection system
Original Equipment Manufacturer (OEM): Siemens
Hydraulic or electronic: electronic
Overspeed protection system (hydraulic [bolt]/electronic): electronic and hydraulic
Axial shaft position monitoring system (hydraulic [nozzle]/electronic): electronic
_
Vibration monitoring system (yes/no): no
Actuators for control and stop valve(s) (HP/LP hydraulic system): no
Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): yes / unknown
Electrohydraulic converter installed (yes/no): yes
Condenser:
Original Equipment Manufacturer (OEM): Serck Como
Condenser model: AA 43 CD 28/40 H 5K 120-2
Condensing capacity (t/h): 9.5
Condenser pressure (bar): -0.8
3
Cooling water flow (m /h): 360
Cooling water velocity (m/s): 1.97
Cooling water inlet temperature (°C): 27
Thermal capacity (MW): 6.384
Supply lines: NW 350
Complete operating documentation available (yes/no): yes
Complete machine file available (yes/no): no
Is the driven machine also available for purchase (yes/no): yes (Generator)
SCF 04/2011 V08.12
Page 2 of 3
Energy
_
Driven generator
Machine No.:
Original Equipment Manufacturer (OEM):
Rating (MVA):
Generator type (cooling system):
Generator model:
Voltage (kV):
Frequency (Hz):
Current (A):
Power factor (cos phi):
Speed (rpm):
Design: e.g. B3
Insulation class:
Type of enclosure:
Cooling water inlet temperature (°C):
Cooling water flow (m3/h):
Compound excitation (… V - … A):
Gear unit:
Original Equipment Manufacturer (OEM):
Gear unit model:
Rating (HP)
Speed (rpm):
Complete scope of supply available for purchase:









Size (footprint) / dimensions:
Please provide photographs of the turboset / turbine separately in electronic form.
SCF 04/2011 V08.12
Page 3 of 3
Download