Data Record for Used Industrial Steam Turbines / Turbosets Turbine Original Equipment Manufacturer (OEM): Siemens Turbomachinery Equipment GmbH (STE) Turbine model: SST-110 TWIN CA56 (CFR5+AFA6) Machine No.: Year of manufacture: 2009 Design output (MW) [at best turbine efficiency]: Maximum output (MW): 3.24 Steam consumption at design output (kg/kWh): 1) _ Steam consumption at max. output (kg/kWh): Max. main steam temperature (°C) : 465 Main steam temperature (°C)1): 420 Main steam pressure (bar g)1): 39 Main steam flow (t/h)1): 16 Exhaust steam temperature (°C)1): 386 Exhaust steam flow (t/h)1): Exhaust steam pressure (bar): 1.3 Extraction pressure (bar g)2): Extraction flow (t/h)2): Speed (rpm): 1,500 Allowable frequency range (Hz): 50 Direction of rotation: Exhaust steam nozzle (downward, upward, right, left or axial): upward Non-drive end of turbine (HP/LP end): gear Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): In case of package, is integral lube oil system provided? (yes/no): or extract from Operating Manual Load points 1 2 3 Main steam parameters Main steam flow (t/h) Extraction pressure (bar) Extraction flow (t/h) Exh. steam pressure (bar) Exh. steam temp. (°C)1) Terminal output (kW) Turbine condition Last minor overhaul: Last major overhaul: 11/2013 Operating hours: 33,943 Date of turbine shutdown and preservation details: still in operation Expected to be available as from: June 2015 1) in accordance with turbine design 2) where applicable Siemens AG Energy Sector; Management: Lisa Davis Energy Service Division; Management: Randy Zwirn Oil & Gas and Industrial Applications Services; Management: Willibald Meixner Frankenstr. 70-80 90461 Nuernberg Germany Tel.: +49 (911) 4130 0 Fax: +49 (911) 4130 440 Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Joe Kaeser, Chairman, President and Chief Executive Officer; Roland Busch, Lisa Davis, Klaus Helmrich, Hermann Requardt, Siegfried Russwurm, Ralf P. Thomas Registered offices: Berlin and Munich, Germany; Commercial registries: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE 23691322 SCF 08/2014 V13.06 Are spare parts available? If yes, which ones? Turbine control and protection system Original Equipment Manufacturer (OEM): Hydraulic or electronic: Overspeed protection system (hydraulic [bolt]/electronic): Axial shaft position monitoring system (hydraulic [nozzle]/electronic): Vibration monitoring system (yes/no): Actuators for control and stop valve(s) (HP/LP hydraulic system): Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): Electrohydraulic converter installed (yes/no): Condenser: Original Equipment Manufacturer (OEM): Condenser model: Condensing capacity (t/h): Condenser pressure (bar): Cooling water flow (m 3/h): Cooling water velocity (m/s): Cooling water inlet temperature (°C): Thermal capacity (MW): Supply lines: Complete operating documentation available (yes/no): yes Complete machine file available (yes/no): yes Is the driven machine also available for purchase (yes/no): no SCF 08/2014 V13.06 Driven generator Machine No.: Original Equipment Manufacturer (OEM): Rating (MVA): Generator type (cooling system): Generator model: Voltage (kV): Frequency (Hz): Current (A): Power factor (cos phi): Speed (rpm): Design: e.g. B3 Insulation class: Type of enclosure: Cooling water inlet temperature (°C): Cooling water flow (m 3/h): Compound excitation (… V - … A): Generator condition Last minor overhaul: Last major overhaul: Operating hours: Date of turbine shutdown and preservation details: Expected to be available as from: Gear unit: Original Equipment Manufacturer (OEM): SIEMENS Gear unit model: single-stage, single helical toothed three-shaft spur gear Rating (HP) Speed (rpm): Complete scope of supply available for purchase: · Turbine TWIN CA 56 · Gear Further notes: · Not included are turbine control and protection system, generator · Scoring at rotor of AFA6, if necessary rotor has to be replaced · · · · Size (footprint) / dimensions: Please provide photographs of the turboset / turbine separately in electronic form. SCF 08/2014 V13.06