ASCO 5210 Digital Power Meter The 5210 Digital Power Meter (DPM) is ASCO’s standard solution for providing deeper transparency into the happenings in an electrical circuit. The meter is used to monitor, communicate, and display key electrical parameters that are critical to understanding the real-time health and activity of loads or power sources. The data given by the meter provides the information needed to make key decisions on-site regarding energy management, optimization, utilization, load planning, or even for general reference. 11:35 12:47 01:42 02:06 Real-Time Monitoring Utilization & Load Planning 118V 16.0A 1.886 kW -0.033 kVAr 1.00PF 60.0Hz 1.887 kVA ON Energy Management 118V 16.0A 1.886 kW -0.033 kVAr 1.00PF 60.0Hz 1.887 kVA ON N Overview 0 AB BC CA V-LL 206 206 206 0 A B C AMPs 437 451 446 Voltage & Current 0 A B C Total WATTs 41.42k 49.27k 45.31k 136.0k PF 0.93 0.87 0.91 kW & Power Factor N kWh - Normal IMPORT EXPORT NET 847.3 0.000 446 Energy Power Meter The DPM includes a backlit graphic LCD display and membrane control (keys). All monitoring and control functions can be done from the front of the unit for convenience and safety. Often times, existing sites are the locations with the most need for added monitoring, but are often the hardest to modify. The 5210 DPM has the flexibility to allow installation in numerous environments. The 5210 can be installed or retrofitted into new or existing Transfer Switches or switchgear. Additionally the 5210 can be purchased premounted in a wall mount enclosure for monitoring third party equipment, or as a loose meter for integration into other systems. Regardless of where it is installed the 5210 will provide the needed data to allow knowledgable and insightful decision making on a daily basis. Monthly Max 2015 Jan 229.2kW Feb 221.3kW Mar 243.9kW Demand 2014 219.1kW 207.3kW 237.6kW Monthly Max. Demand % Full Load 0 AMPs A 60% B 54% C 54% WATTs 58% 52% 55% Utilization VOLTAGE THD 0 A B C % Max kW Summary Last 60 Mins 136.0kW Last 24 Hr 157.4kW Last 30 Day 198.7kW Last 12 Month 243.9kW Max. Demand THD 3.69 3.37 3.15 Total Harmonic Distortion % AMPs V-LL V-LN AVG UNBAL 444.6 2% 206.3 1% 118.9 1% Unbalanced Getting the meter running is as easy as simply wiring the voltage sense lines and current transformers, since it runs off the monitored voltage, saving the time and money of wiring additional, and often difficult to find, control power. Once connected the meter will instantly begin displaying basic data such as voltage, current, and power along with advanced metrics such as total harmonic distortion, kW demand, and energy. All the monitored data is available over Modbus via the onboard serial connection or via the optional Ethernet module which includes a remote and mobile friendly webpage. ASCO 5210 Digital Power Meter Specifications Metered Parameters • Voltages • Total Harmonic Distortion (%) • Current • Utilization • Power (kW, kVA & kVAR) & Power Factor • kW Demand (multiple periods and historical) Complies to NEC 220.87 • Frequency • Engine Run Time • Energy (kWh, kVAh & kVARh) • Min/Max Historical Values Device Ratings Current 0 to 5 ac nominal secondary CT. 4000 V ac isolation, minimum Burden: Less than 0.25 VA per phase Voltage 70 to 600 V ac nominal, phase to phase (Expandable via power transformers for medium voltage applications) Frequency Source Selection Input 45 Hz to 65 Hz fundamental. True RMS measurements up to and including the 31st harmonic. 26 V dc maximum, >10 V dc = active, <1 V dc = inactive AC Power Requirements Minimum 70 V L-L Ac/103 mA / 7.2 VA with 50/60 Hertz (Parasitic from voltage sense lines) DC Power Requirements Optional backup power supply 9-36 V dc 10 watts. DC power supply should be UL Listed. User Interface(s) Isolated RS485 - 2/4 Wire (for external Modbus RTU communication) Optional ASCO Ethernet communication module Operating Temperature -4°F to 158°F (-20°C to 70°C) Storage Temperature -22°F to 176°F (-30°C to 80°C) Measurement Category Pollution Degree III PD 2 Humidity Relative humidity 5% to 85%, non-condensing Accuracy1 0.25% Current, Voltage, Power, Frequency 1.00% Energy, Power Factor, Demand Standards UL 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use — Part 1: General Requirements CSA-C22.2 No. 61010-1, 2nd Edition, 2004-07 Electrical Equipment for Measurement, Control and Laboratory Use — Part 1: General Requirements Ordering Information Transfer Switch Accessory Acc 135 Family Acc 150A for ATS2 Acc 150B for BPS2, 3 Tech Bundle Accessory 5210 DPM Standalone Meter Kit (Meter & Manual Only) PN# 966071 In Type 1 Enclosure (5211 PMU)2, 4 PN# 947905 In Type 1 Enclosure with IO (5212 PMU) 2, 4 PN# 997684 Notes: 1 Further accuracy details available upon request in user manual. 2 Includes ride through power module and ethernet communication module. 3 Includes discrete IO module for bypass status. 4 Enclosures include shorting blocks, fusing and auxiliary power supply. ASCO 5210 Digital Power Meter mounted on a transfer switch including optional ASCO Ethernet communication module. (Remote webpage shown) Emerson Network Power ASCO Power Technologies 50 Hanover Road, Florham Park, NJ 07932 EmersonNetworkPower.com/ASCO customercare@asco.com 1-800-800-ASCO (2726) Emerson, Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©August, 2015 Emerson Electric Co. Publication 2009