ASCO 5210 Digital Power Meter

advertisement
ASCO 5210 Digital Power Meter
The 5210 Digital Power Meter (DPM) is ASCO’s standard solution for providing deeper transparency into the happenings
in an electrical circuit. The meter is used to monitor, communicate, and display key electrical parameters that are critical
to understanding the real-time health and activity of loads or power sources. The data given by the meter provides the
information needed to make key decisions on-site regarding energy management, optimization, utilization, load planning, or even for general reference.
11:35
12:47
01:42
02:06
Real-Time Monitoring
Utilization & Load Planning
118V
16.0A
1.886 kW
-0.033 kVAr
1.00PF
60.0Hz
1.887 kVA
ON
Energy Management
118V
16.0A
1.886 kW
-0.033 kVAr
1.00PF
60.0Hz
1.887 kVA
ON
N
Overview
0
AB
BC
CA
V-LL
206
206
206
0
A
B
C
AMPs
437
451
446
Voltage & Current
0
A
B
C
Total
WATTs
41.42k
49.27k
45.31k
136.0k
PF
0.93
0.87
0.91
kW & Power Factor
N
kWh - Normal
IMPORT
EXPORT
NET
847.3
0.000
446
Energy
Power Meter
The DPM includes a backlit graphic LCD display and membrane control (keys).
All monitoring and control functions can be done from the front of the unit
for convenience and safety.
Often times, existing sites are the locations with the most
need for added monitoring, but are often the hardest to
modify. The 5210 DPM has the flexibility to allow installation in numerous environments. The 5210 can be installed
or retrofitted into new or existing Transfer Switches or
switchgear. Additionally the 5210 can be purchased premounted in a wall mount enclosure for monitoring third
party equipment, or as a loose meter for integration into
other systems. Regardless of where it is installed the 5210
will provide the needed data to allow knowledgable and
insightful decision making on a daily basis.
Monthly Max
2015
Jan 229.2kW
Feb 221.3kW
Mar 243.9kW
Demand
2014
219.1kW
207.3kW
237.6kW
Monthly Max. Demand
% Full Load
0
AMPs
A
60%
B
54%
C
54%
WATTs
58%
52%
55%
Utilization
VOLTAGE THD
0
A
B
C
%
Max kW Summary
Last 60 Mins 136.0kW
Last 24 Hr
157.4kW
Last 30 Day
198.7kW
Last 12 Month 243.9kW
Max. Demand
THD
3.69
3.37
3.15
Total Harmonic Distortion %
AMPs
V-LL
V-LN
AVG UNBAL
444.6
2%
206.3
1%
118.9
1%
Unbalanced
Getting the meter running is as easy as simply wiring the
voltage sense lines and current transformers, since it runs off
the monitored voltage, saving the time and money of wiring
additional, and often difficult to find, control power. Once
connected the meter will instantly begin displaying basic
data such as voltage, current, and power along with advanced
metrics such as total harmonic distortion, kW demand, and
energy. All the monitored data is available over Modbus via
the onboard serial connection or via the optional Ethernet
module which includes a remote and mobile friendly webpage.
ASCO 5210 Digital Power Meter Specifications
Metered Parameters
• Voltages
• Total Harmonic Distortion (%)
• Current
• Utilization
• Power (kW, kVA & kVAR) & Power Factor
• kW Demand (multiple periods and historical) Complies to NEC 220.87
• Frequency
• Engine Run Time
• Energy (kWh, kVAh & kVARh)
• Min/Max Historical Values
Device Ratings
Current
0 to 5 ac nominal secondary CT. 4000 V ac isolation, minimum
Burden: Less than 0.25 VA per phase
Voltage
70 to 600 V ac nominal, phase to phase (Expandable via power transformers for medium voltage applications)
Frequency
Source Selection Input
45 Hz to 65 Hz fundamental. True RMS measurements up to and including the 31st harmonic.
26 V dc maximum, >10 V dc = active, <1 V dc = inactive
AC Power Requirements
Minimum 70 V L-L Ac/103 mA / 7.2 VA with 50/60 Hertz (Parasitic from voltage sense lines)
DC Power Requirements
Optional backup power supply 9-36 V dc 10 watts. DC power supply should be UL Listed.
User Interface(s)
Isolated RS485 - 2/4 Wire (for external Modbus RTU communication)
Optional ASCO Ethernet communication module
Operating Temperature
-4°F to 158°F (-20°C to 70°C)
Storage Temperature
-22°F to 176°F (-30°C to 80°C)
Measurement Category
Pollution Degree
III
PD 2
Humidity
Relative humidity 5% to 85%, non-condensing
Accuracy1
0.25% Current, Voltage, Power, Frequency
1.00% Energy, Power Factor, Demand
Standards
UL 61010-1
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use
— Part 1: General Requirements
CSA-C22.2 No. 61010-1, 2nd Edition, 2004-07
Electrical Equipment for Measurement, Control and Laboratory Use
— Part 1: General Requirements
Ordering Information
Transfer Switch Accessory
Acc 135 Family
Acc 150A for ATS2
Acc 150B for BPS2, 3
Tech Bundle Accessory
5210 DPM
Standalone Meter Kit (Meter & Manual Only)
PN# 966071
In Type 1 Enclosure (5211 PMU)2, 4
PN# 947905
In Type 1 Enclosure with IO (5212 PMU)
2, 4
PN# 997684
Notes: 1 Further accuracy details available upon request in user manual.
2 Includes ride through power module and ethernet communication module.
3 Includes discrete IO module for bypass status.
4 Enclosures include shorting blocks, fusing and auxiliary power supply.
ASCO 5210 Digital Power Meter mounted on a transfer switch including
optional ASCO Ethernet communication module. (Remote webpage shown)
Emerson Network Power
ASCO Power Technologies
50 Hanover Road, Florham Park, NJ 07932
EmersonNetworkPower.com/ASCO
customercare@asco.com 1-800-800-ASCO (2726)
Emerson, Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©August, 2015 Emerson Electric Co.
Publication 2009
Download