VIPR Fire Equipment Incident Inspection Checklist PUMPER CAT INCIDENT INSPECTION CHECKLIST INCIDENT NAME: April 1, 2015 Date: ___________ Time: __________ ___________________ INCIDENT NUMBER: ____________________ RESOURCE #: E- COMPANY/CONTRACTOR:_________________________________________________________________ AGREEMENT NUMBER: ___________________________________________________________________ EQUIPMENT MAKE: _______________________________ MODEL: _______________________________ VIN/SERIAL #: ____________________________________________________________________________ OPERATOR NAME: ______________________________________________________________________________________ EQUIPMENT and OPERATOR REQUIREMENTS PUMPER CAT Type 1: Type 2: Type 3: (see table below for minimum requirements) Minimum Requirements Not all inclusive; for additional clarification refer to agreement (SF-1449 section D) 1 2 3 Agreement (One complete copy) (D.8) Check-In Process: Completed (Note: Also includes; Finance, and Plans) (D.6.5.3) Equipment VIN/Serial # matches Resource Order (may also have to verify on DPL): Note: This is also a business rule that could affect payment. 4 5 6 7 Yes RT-130 Fire Line Refresher current for all personnel Incident Pre-Use Inspection Completed (Schedule of Items) (D.6.3.1) (D.3.1) (OF-296 Vehicle/Heavy Equipment Mechanical Inspection) Equipment arrived at incident washed: (Debris and noxious weeds free) (D.17) (D.17.1) (D.15) Written “Aftermarket” certification: Certification from a licensed mechanical engineer or original equipment manufacturer that design limits of equipment has not been compromised, and mounting hardware is rated for the load secured. 8 9 (D.2.1.2) ROPS; A manufactures nameplate certifying the operator enclosure or alternative documentation that the cab meets these provisions is required (D.2.1.1) Operator Protection; Forestry cab which meets all applicable federal and state (the state where equipment is registered) safety standards (per OSHA, 29 CFR 1910.266) for the year machine was constructed (D.2.1.1) (D.2.1.2) 10 Deflectors: Installed in front of the operator (D.2.1.2) 11 *Underbody protection: Belly pan, rock guards unless not recommended by manufacturer 12 Tank baffling: One longitudinal baffle and one transverse baffle every 52” or free floating baffle system 13 14 15 16 17 18 19 20 with data sheets that validates baffling is sufficient to meet manufactures recommendation (D.2.1.2) Tank: Securely attached to the chassis. Fiberglass or plastic tanks must be surrounded by steel to prevent puncture damage. (D.2.1.2) Fire Extinguisher: 2A 10BC, with current inspection tag. Securely mounted to vehicle (D.2.1.2) *Seat Belt(s) (D.2.1.2) Flashlight (D.2.1.2) Water: At least 1 gallon drinking water (D.2.1.2) First aid kit: 5 person minimum (D.2.1.2) PPE: Boots Hard Hat Gloves Eye Protection Hearing Protection Headlamp with batteries (D.2.1.2) Fire Shelter: New generation shelter (D.2.1.2) No VIPR Fire Equipment Incident Inspection Checklist 21 Flame Resistant Clothing: April 1, 2015 Two Full Sets (D.2.1.2) Equipment Inventory 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 (Exhibit M) Hose Reel: Operational, minimum 150 feet of 1 inch hard line hose (D.2.1.2.3) Hose, 1 inch: Minimum of 200 feet (D.2.1.2.3) Hose Clamp: Forestry type. 1 each Spanner Wrench: Combination 1 inch to 2 inch. 1 each Nozzles: Combination fog / straight stream. 2 each. Fitting: Double Male, 1 inch NPSH. 1 each Fitting: Double Female, 1 inch NPSH. 1 each Adapter: 1 inch NH Female to 1inch NPSH Male. 1 each Adapter: 1 inch NPSH Female to 1 inch NH Male. 1 each Reducer: 1 ½ inch NH Female to 1 inch NPSH Male. 1 each Reducer: 1 inch NPSH to ¾ inch (garden hose). 1 each Shovel: 1 each Pulaski: 1 each Discharge Outlet: 1 inch NPSH 1 each (D.2.1.2.3) Fill Pipe: 4 inch minimum Dump Valve: 3 inch minimum. Capable of dumping into a port-a-tank Pump: Pump Type Auxiliary or Power Take Off (PTO) (D.2.1.2) Auxiliary pump (if equipped): Fuel to operate pump, minimum 5 gallons and Pump accessories ( i.e. Pliers, Oil, Screwdrivers etc.) 40 41 42 43 --44 45 46 Pump: Discharge Pressure Gauge Pump: 20 foot suction hose Lighting: Minimum 2 rear, 2 forward Back-Up Alarm: Audible reverse warning device. ****(Optional/Attributes)**** Winch: Operable Foam Proportioner System: Manual Automatic Compressed Air Foam System: *Item may be waived if inspection successfully performed on the OF-296 Equipment meets agreement specifications (D.2.1.2) (D.2.1.2) ----- ----- (D.2.1.2.3) (D.6.2) (D.2.1.2) (D.6.2) (D.2.1.2.1) Equipment does not meet agreement specifications Inspector: Date: (Print and sign) Contractor: Date: (Print and sign) Contractor given the opportunity to correct noted deficiencies (See Remarks) Contactor successfully corrected noted deficiencies Inspector: Date: REMARKS:__________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ VIPR Fire Equipment Incident Inspection Checklist April 1, 2015 _____________________________________________________________________________________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ REQUIREMENTS Tank Capacity (gallons) Minimum Maximum Flywheel HP Range Pump Min Flow (gpm) @ rated pressure (psi) 1” hard line with ¾” inside diameter hose on reel 1 inch linen hose Discharge Outlet Pump and Roll Foam Proportioner System Winch or Grapple Personnel Required TYPE 1 TYPE 2 TYPE 3 500 NONE 200 30 70 325 499 100-199 30 70 200 324 60-99 30 70 150 feet 150 feet 150 feet 200 feet 1” NPSH Yes Optional 200 feet 1” NPSH Yes Optional 200 feet 1” NPSH Yes Optional Optional 1 Optional 1 Optional 1