Industrial Power for Business-Critical Continuity

advertisement
Chloride CP-70Z 33 UL AC UPS System
5 to 500kVA – 3ph output
Industrial Power for
Business-Critical Continuity™
Chloride CP-70Z industrial Uninterruptible
Power Supply (UPS) system is the flagship
product of Chloride Industrial Power. It
combines conservative design topology with
proven digital control technology to offer
the best performances in any electrical and
environmental condition.
Custom-designed AC UPS systems to secure critical industrial processes.
The Chloride CP range is designed to meet the
stringent electrical and mechanical requirements in industrial environments.
Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical
specification and with project documentation
requirements.
The CP-70Z 33 is a range of three-phase input / three-phase output AC UPS systems
available from 5kVA to 120kVA. It offers a wide choice of DC battery voltages and of
output voltages.
Benefits
Tailor made systems to comply with all customer’s
specifications
Ruggedized solutions for demanding environments:
high temperatures, vibrations, dust, elevation, dripping water and moisture
Efficient maintenance thanks to easy front access to
all critical modules of the system
Key Features
Reliability - Unique design which allows the UPS to
continuously operate for at least 20 years at full load
at 104°F (40°C)
Robust mechanical design - The system withstands
vertical and horizontal acceleration stress tests up to
0.5g as standard
Galvanic isolation - Input and output transformers
are included as standard
Multilingual digital graphic display with embedded
event log
Remote monitoring capabilities: Modbus, Profibus, DF1, Ethernet, volt-free contacts, monitoring
software
Fully customized electrical and mechanical solutions
– On demand design to comply with every standard
(e.g. UL, ANSI, NEMA, IEC, CSA, ABS, DNV)
Full compatibility with Lead-acid and Nickel-Cadmium batteries, valve regulated or flooded
Applications
The Chloride CP-70Z AC UPS system protects heavy-duty
applications of the following industries:
Oil & Gas offshore and onshore
Refining and petrochemical
Conventional power generation
Transportation (rail, metro, tramway)
Associated with an industrial stand-by battery, the Chloride CP-70Z 33 protects
critical industrial AC equipments and processes from the damaging effects of power
interruption and losses. It uses the patented digital Vector Control technology which
increases the performances of power components and enables an active conditioning of the load. The result is improved reliability for the process and enhanced
safety for the personnel.
The CP-70Z 33 range can be customized to meet higher power needs, up to 500kVA
three-phase output.
To further improve load availability and process reliability, the CP-70Z 33 is able to
operate in dual parallel configuration, with single or dual batteries, with centralized
or distributed reserve line, and can include a DC and/or AC bus-tie.
Chloride CP-70Z 33 UL AC UPS System
Ratings - Output Power at cos phi 0.8 (kVA) vs DC intermediate voltage (Vdc)
110-120Vdc
5
7.5
10
15
20
25
30
40
50
-
220-240 Vdc
15
20
25
30
40
50
60
80
100
Up to 500 kVA on request
400 Vdc
40
50
60
80
100
120
Technical Data
Input
Input voltage (other voltage on request)
Voltage tolerance
Frequency
60 Hz (50 Hz)
Frequency tolerance
±5%
Intermediate DC circuit
Nominal DC voltage
110 - 120 / 220 - 240 / 400 Vdc
Voltage stability
±1% in float mode, input within tolerance
±1.5% for parallel rectifiers
Voltage ripple (battery connected)
1% RMS in float, battery connected
Output
Available ratings
see table on the left
AC voltage:
• Three phase
3 x 208 (220)
3 x 480 (380, 400, 415)
Options
Rectifier
Battery
Reserve
System
Mechanical
Communication
Specified three-phase input voltage (from 3 x 208 to 3x600Vac)
12 pulse rectifier
Harmonic filter
Ripple filter
Blocking diode
Inrush current limitation to 8In
Surge and lightning protections
Battery circuit protection box
Battery cabinet or rack
Low-voltage disconnect contactor
Battery Management System
Battery room temperature sensor
By-pass transformer
By-pass stabilizer
By-pass harmonic filters
Extended operating temperature range up to 122°F (50°C)
Dual parallel configurations
Hot stand-by configuration
Specified input / intermediate / output isolators
DC/DC serial regulator
isolated DC/DC converter
AC distribution
Earth fault monitoring
Backfeed protection
Internal lighting
Anti-condensation heater
Tenmerature monitor
Special cabinet identification
NEMA 1, 1x, 2
Top or bottom cable entry
Other frame color
Anti-seismic design
Front-panel analog meters
Transducers
Additional volt-free contacts
industrial protocols (Modbus, Profibus, DF1, etc...)
Passive or active mimic panel
Monitoring software PPVis
Non-exhaustive list of options. Consult us for any other requirement.
Frequency
60 Hz (50 Hz)
Frequency stability (free running)
±0.05%
Frequency tracking range
±4% (from 1.2 to 6% adjustable)
Voltage stability (0-100% load variation):
• static (balanced load)
• dynamic
+/-1% (±2% for parallel inverters)
+/-5%
Overload inverter:
• 10 min
• 1 min
150% of nominal power
125% of nominal power
Short-circuit clearance:
• 100 ms
•5s
315% of nominal current (Ph-N)
220% of nominal current (Ph-N)
Harmonic voltage distortion:
• with 100% linear load
• with 100% non linear load - CF 3:1
<3%
≤5%
Allowable power factor
0.5 lagging to 0.5 leading
Allowable crest factor
3:1
Battery
Type
Lead Acid or Nickel Cadmium,
valve regulated or flooded
Autonomy
As per customer’s requirement
Recommended float / charge voltage per
cell
2.25V (Lead-Acid battery)
1.4-1.45V (Nickel-Cadmium battery)
Recommended boost voltage per cell
2.33V (Lead-Acid battery)
1.45-1.52V (Nickel-Cadmium battery)
General Data
Efficiency
up to 90% at full load, according to rating
Operating temperature
32 to 104°F (0 to 40°C)
up to 122°F (50°C) on request
Storage temperature
-4 to 158°F (-20 to +70°C) (battery excluded)
Relative humidity
<90 % non condensing at 68°F (20 °C)
Operating altitude
0 to 3,200 ft (1,000 m ) above sea level,
without system derating
Cooling
Forced
External protection
Standards
Compliance
UL1778, IEEE, NEC
Conformity
UL Label
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
Emerson Network Power
11100 Brittmoore Park Drive - Houston - TX77041 - USA
T: +1 713 827 4309
us.cis.sales.chloride@Emerson.com
EmersonNetworkPower.com
3 x 480V
±10% without discharging batteries
NEMA 1 according to IEEE-250
Noise
60-75dB at 6 ft (depending on rating)
Frame colour
Gray ANSI-61
Dimensions
Varying according to ratings and options
AC Power
Embedded Power
Power Switching & Controls
Connectivity
Industrial Power
Precision Cooling
DC Power
Infrastructure Management & Monitoring
Racks & Integrated Cabinets
Embedded Computing
Outside Plant
Services
While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network Power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Industrial Power for
Business-Critical Continuity™
5 to 500 kVA - 3 ph output
Emerson, Business-Critical Continuity and
Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©2013 Emerson Electric Co.
CP70Z 33 UL AC UPS System-DSUS-Rev0-09/2013