Chloride CP-70Z 33 AC UPS System 5 to 500kVA - 3ph output The Chloride CP-70Z industrial Uninterruptible Power Supply system (UPS) is the flagship product of Chloride Industrial Power. It combines conservative design topology with proven digital control technology to offer the best performances in any electrical and environmental condition. The Chloride CP range is designed to meet the stringent electrical and mechanical requirements in industrial environments. Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical specification and with project documentation requirements. Benefits n n n n High Reliability from an industry leader with more than 60 years of experience. Tailor made systems to comply with all customer specifications. Ruggedized solutions for demanding environments: extended temperatures, vibrations, dust, elevation, dripping water and moisture. Efficient maintenance thanks to easy frontaccess to all vital modules of the system. Key Features n n n n n n n n Reliability - Unique design which allows the UPS to continuously operate for at least 20 years at full load at a permanent 40°C ambient temperature. On-line double conversion - UPS classified VFI SS 111 as per IEC62040-3 Robust mechanical design - the system withstands vertical and horizontal acceleration stress tests up to 0.5g as standard Galvanic isolation - input and output transformers as standard Multilingual digital graphic display with embedded event log Remote monitoring capabilities: Modbus, Profibus, DF1, ethernet, volt-free contact, monitoring software Fully customized electrical and mechanical solutions - On demand design to comply with every standards (e.g. UL, ANSI, NEMA, IEC, CSA, ABS, DNV) Full compatibility with lead-acid and nickelcadmium batteries sealed or vented Applications The Chloride CP-70Z AC UPS System range suits all applications such as: n Oil and Gas offshore and onshore n Refining and petrochemical plants n Power generation plants n Transportation (rail, metro, tramway) Industrial Power for Business-Critical Continuity™ The Chloride CP range is designed to meet the harshest electrical and mechanical requirements in industrial environments. Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical specification and with project documentation requirements. Associated with an industrial stand-by battery, the Chloride CP-70Z 33 range is dedicated to protect critical industrial three phase AC equipments and processes from the damaging effects of power interruption and losses. Chloride CP-70Z 33 UPS System Ratings - Output power (kVA) vs DC intermediate voltage (Vdc) 110–120Vdc 220-240Vdc Technical Data 400Vdc 5 Input AC voltage 3 x 400V (380, 415)* 7.5 Voltage tolerance +/- 10% 10 Frequency 50Hz (60Hz) +/- 5% 15 15 Frequency tolerance 20 20 Intermediate DC Circuit 25 25 Nominal DC voltage 110 / 120 / 220 / 240 / 400 V 30 30 Voltage stability 40 40 40 +/- 1% in float mode, input within tolerance +/-1.5% for parallel rectifiers 50 50 50 Voltage ripple 1% RMS, in float, battery connected 60 60 Current limitation I nominal 80 80 Charging characteristic UI according to DIN 41773 100 100 120 Up to 500 kVA on request Options Rectifier Battery System 12-pulse rectifier Harmonic filter Ripple filters Blocking diode Other input voltage (3x190 to 3x690VAC) Inrush current limitation to 8In Surge and Lightning protections Battery circuit protection box Battery cabinet Low-voltage disconnect contactor Battery Management System Battery room temperature sensor Dual configurations Hot stand-by configuration Input / intermediate /output isolators DC/DC serial regulator isolated DC/DC converter AC distribution Earth fault monitoring Backfeed protection Internal lighting Anti-condensation heater Temperature monitor Special cabinet identification Reserve transformer Reserve stabilizer Up to IP42 external Top cable entry Other frame colour Anti-seismic design Communication Front-panel analog meters (72x72 class 1.5) Transducers Additional Volt-free contacts Remote monitoring via Modbus Remote monitoring via other bus PPVis monitoring software Passive or active mimic panel Non-exhaustive list of options. Consult us for any other requirement. Standards Conformity Available ratings see table above (at PF 0.8 lagging) AC Voltage 3 x 400V (380, 415) ; 3 x 220V (190, 208)* Frequency 50Hz (60Hz) Frequency stability Mechanical Compliance Output IEC 62040 (-1, -2, -3) / 60146 (-1-1, -1-3, -2) / IEC 60950 IEC 61000-6-2 - IEC 61000-6-4 IEC 60529 / IEC 60439 / IEC 60076 Low voltage directive: 2006/95/EC EMC directive: 2004/108/EC CE Mark Emerson Network Power. The global leader in enabling Business-Critical Continuity™. n AC Power n Connectivity n DC Power n Embedded Computing Emerson Network Power IS S.A.S 30 Avenue Montgolfier - BP90 - 69684 Chassieu Cedex France T: +33 (0)4 78 40 13 56 F: +33 (0)4 78 90 58 90 Industrial.Sales.Chloride@Emerson.com EmersonNetworkPower.com • with internal oscillator +/- 0.5% • with reserve synchronism +/-3% (from 0.2 to 6% adjustable) Frequency response <1Hz/s (0.1Hz/s for parallel systems) Voltage stability (for 0-100% load variation) • static +/-1% (+/-2% for parallel systems) • dynamic +/-2% (+/-3% for parallel systems) Overload inverter • 1 minute 150% of nominal power • 10 minutes 125% of nominal power Short circuit clearance • 100 ms 315% of nominal current (Ph-N) • 5 s 220% of nominal current (Ph–N) Distortion • With 100% linear load 3% • With 100% non-linear load Complies with IEC 62040-1-2 Allowable power factor 0.5 lagging to 0.5 leading Allowable crest factor 3 Battery Type Lead Acid or Nickel Cadmium vented or recombination Autonomy From few minutes to several hours, as per customer’s requirement Battery current limitation (typical, float & charge modes) 0.1C (Lead Acid battery) 0.2C (Nickel Cadmium battery) Battery current limitation (typical, boost mode) 0.05C (Lead acid battery) 0.1C (Nickel Cadmium battery) General Data Operating temperature 0 to 40°C* Storage temperature (°C) -20 to +70°C Relative humidity (%) <90% non condensing Operating altitude (m) 1000 m max without derating Cooling Forced ventilation Efficiency Up to 90% according to rating External protection IP 20* according to IEC 60529 Noise (dB) 60 – 75 dB according to rating Frame colour Grey RAL 7032 Dimensions Varying according to ratings & options * other options available on request n Embedded Power n Industrial Power n Infrastructure Management & Monitoring n Outside Plant n Power Switching & Controls n Precision Cooling n Racks & Integrated Cabinets n Services Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Electric Co. CP70Z 33 AC UPS System-DSUK-Rev2-02/2013 While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Industrial Power for Business-Critical Continuity™ 5 to 500 kVA - 3ph output