Chloride CP-70Z 33 AC UPS System
5 to 500kVA - 3ph output
The Chloride CP-70Z industrial
Uninterruptible Power Supply system
(UPS) is the flagship product of
Chloride Industrial Power. It combines
conservative design topology with
proven digital control technology to offer
the best performances in any electrical
and environmental condition.
The Chloride CP range is designed to meet the
stringent electrical and mechanical requirements in industrial environments.
Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical
specification and with project documentation
requirements.
Benefits
n
n
n
n
High Reliability from an industry leader with
more than 60 years of experience.
Tailor made systems to comply with all
customer specifications.
Ruggedized solutions for demanding
environments: extended temperatures,
vibrations, dust, elevation, dripping water and
moisture.
Efficient maintenance thanks to easy frontaccess to all vital modules of the system.
Key Features
n
n
n
n
n
n
n
n
Reliability - Unique design which allows the
UPS to continuously operate for at least 20
years at full load at a permanent 40°C ambient
temperature.
On-line double conversion - UPS classified VFI
SS 111 as per IEC62040-3
Robust mechanical design - the system
withstands vertical and horizontal acceleration
stress tests up to 0.5g as standard
Galvanic isolation - input and output
transformers as standard
Multilingual digital graphic display with
embedded event log
Remote monitoring capabilities: Modbus,
Profibus, DF1, ethernet, volt-free contact,
monitoring software
Fully customized electrical and mechanical
solutions - On demand design to comply with
every standards (e.g. UL, ANSI, NEMA, IEC, CSA,
ABS, DNV)
Full compatibility with lead-acid and nickelcadmium batteries sealed or vented
Applications
The Chloride CP-70Z AC UPS System range suits all
applications such as:
n Oil and Gas offshore and onshore
n Refining and petrochemical plants
n Power generation plants
n Transportation (rail, metro, tramway)
Industrial Power for
Business-Critical Continuity™
The Chloride CP range is designed to meet the harshest electrical and
mechanical requirements in industrial environments.
Each Chloride CP product is based on interchangeable sub-assemblies to allow
full customization, in compliance with client’s technical specification and with
project documentation requirements.
Associated with an industrial stand-by battery, the Chloride CP-70Z 33 range
is dedicated to protect critical industrial three phase AC equipments and
processes from the damaging effects of power interruption and losses.
Chloride CP-70Z 33 UPS System
Ratings - Output power (kVA) vs DC intermediate voltage (Vdc)
110–120Vdc
220-240Vdc
Technical Data
400Vdc
5
Input
AC voltage
3 x 400V (380, 415)*
7.5
Voltage tolerance
+/- 10%
10
Frequency
50Hz (60Hz)
+/- 5%
15
15
Frequency tolerance
20
20
Intermediate DC Circuit
25
25
Nominal DC voltage
110 / 120 / 220 / 240 / 400 V
30
30
Voltage stability
40
40
40
+/- 1% in float mode, input within tolerance
+/-1.5% for parallel rectifiers
50
50
50
Voltage ripple
1% RMS, in float, battery connected
60
60
Current limitation
I nominal
80
80
Charging characteristic
UI according to DIN 41773
100
100
120
Up to 500 kVA on request
Options
Rectifier
Battery
System
12-pulse rectifier
Harmonic filter
Ripple filters
Blocking diode
Other input voltage (3x190 to 3x690VAC)
Inrush current limitation to 8In
Surge and Lightning protections
Battery circuit protection box
Battery cabinet
Low-voltage disconnect contactor
Battery Management System
Battery room temperature sensor
Dual configurations
Hot stand-by configuration
Input / intermediate /output isolators
DC/DC serial regulator
isolated DC/DC converter
AC distribution
Earth fault monitoring
Backfeed protection
Internal lighting
Anti-condensation heater
Temperature monitor
Special cabinet identification
Reserve transformer
Reserve stabilizer
Up to IP42 external
Top cable entry
Other frame colour
Anti-seismic design
Communication
Front-panel analog meters (72x72 class 1.5)
Transducers
Additional Volt-free contacts
Remote monitoring via Modbus
Remote monitoring via other bus
PPVis monitoring software
Passive or active mimic panel
Non-exhaustive list of options. Consult us for any other requirement.
Standards
Conformity
Available ratings
see table above (at PF 0.8 lagging)
AC Voltage
3 x 400V (380, 415) ; 3 x 220V (190, 208)*
Frequency
50Hz (60Hz)
Frequency stability
Mechanical
Compliance
Output
IEC 62040 (-1, -2, -3) / 60146 (-1-1, -1-3, -2) / IEC 60950
IEC 61000-6-2 - IEC 61000-6-4
IEC 60529 / IEC 60439 / IEC 60076
Low voltage directive: 2006/95/EC
EMC directive: 2004/108/EC
CE Mark
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
n AC Power
n Connectivity
n DC Power
n Embedded Computing
Emerson Network Power IS S.A.S
30 Avenue Montgolfier - BP90 - 69684 Chassieu Cedex France
T: +33 (0)4 78 40 13 56 F: +33 (0)4 78 90 58 90
Industrial.Sales.Chloride@Emerson.com
EmersonNetworkPower.com
• with internal oscillator
+/- 0.5%
• with reserve synchronism
+/-3% (from 0.2 to 6% adjustable)
Frequency response
<1Hz/s (0.1Hz/s for parallel systems)
Voltage stability
(for 0-100% load variation)
• static
+/-1% (+/-2% for parallel systems)
• dynamic
+/-2% (+/-3% for parallel systems)
Overload inverter
• 1 minute
150% of nominal power
• 10 minutes
125% of nominal power
Short circuit clearance
• 100 ms
315% of nominal current (Ph-N)
• 5 s
220% of nominal current (Ph–N)
Distortion
• With 100% linear load
3%
• With 100% non-linear load
Complies with IEC 62040-1-2
Allowable power factor
0.5 lagging to 0.5 leading
Allowable crest factor
3
Battery
Type
Lead Acid or Nickel Cadmium vented or recombination
Autonomy
From few minutes to several hours, as per customer’s
requirement
Battery current limitation
(typical, float & charge modes)
0.1C (Lead Acid battery)
0.2C (Nickel Cadmium battery)
Battery current limitation
(typical, boost mode)
0.05C (Lead acid battery)
0.1C (Nickel Cadmium battery)
General Data
Operating temperature
0 to 40°C*
Storage temperature (°C)
-20 to +70°C
Relative humidity (%)
<90% non condensing
Operating altitude (m)
1000 m max without derating
Cooling
Forced ventilation
Efficiency
Up to 90% according to rating
External protection
IP 20* according to IEC 60529
Noise (dB)
60 – 75 dB according to rating
Frame colour
Grey RAL 7032
Dimensions
Varying according to ratings & options
* other options available on request
n Embedded Power
n Industrial Power
n Infrastructure Management & Monitoring
n Outside Plant
n Power Switching & Controls
n Precision Cooling
n Racks & Integrated Cabinets
n Services
Emerson, Business-Critical Continuity and
Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©2013 Emerson Electric Co.
CP70Z 33 AC UPS System-DSUK-Rev2-02/2013
While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Industrial Power for
Business-Critical Continuity™
5 to 500 kVA - 3ph output
Download