PowerScale 10-50kVA Ed. 02.02.2011 Maximize your availability www.newavenergy.com Contents • Range • Features and Performance • Mechanical Construction • Battery Configuration • External Batteries – Battery Cabinet • Connectivity • Options and accessories www.newaveups.com 02.02.2011 2 Range Technology : On-Line, transformer less Power range : 10 ,15, 20, 25,30 ,40,50 kVA (3ph/3ph) Rated at PF : cosphi 0.9 Type A Type B 10kVA 10kVA 15kVA 15kVA 20kVA 20kVA 25kVA Type C 25kVA 30kVA 40kVA 50kVA 345 x 720 x 710 345 x 1045 x 710 440 x 1400 x 910 60-62-64kg 88-90-92-94kg 135-145-150-155kg www.newaveups.com 02.02.2011 3 Features and performance • Generalities • LCD Display • Input PFC • Input THDI • Efficiency • Active Power vs cosphi www.newaveups.com 02.02.2011 4 Features and performance True on-line double conversion (VFI) Generalities Power Factor 0.9 High efficiency (up to 95.5%) Input PFC: 0.99 @ 100% load Input THDi < 3 % Parallelable up to 20 units Cab C Cab B Cab A Electronic and manual bypass Manual/Automatic Battery test Fan speed temperature regulated Easy to install, service and manoeuvre Flexible battery autonomy space within 3 different cabinets size (A,B,C) Single or Dual input feed RS 232 + 4 potential free input contacts SNMP card slot / Pot. Free Output card slot Multi language LCD display E/S/D/F/P Wide Input voltage windows <@100% load(-23% / +15%) <@80% load (-30% / +15%) <@60% load (-40% / +15%) www.newaveups.com 02.02.2011 5 Features and performance LCD Display LCD Display LINE 2 LINE 1 ON / OFF BY PASS INV BATTERY RESET ENTER ON / OFF ALARM Most important info available at first glance www.newaveups.com 02.02.2011 6 Features and performance Input PFC Advanced Booster PFC circuit to provide near-unity Input PF even with partial loads. 1 0.96 Input PF (%) 0.9 0.985 0.99 0.99 0.8 0.7 0.6 Benefits: • No phase compensation filter required • Respect power grid regulations • Energy savings Reduced TCO 0.5 25% 50% 75% 100% Load (%) www.newaveups.com 02.02.2011 7 Features and performance THDi Input THD versus load Advanced Booster PFC circuit to provide Flat THDi Curve even with partial loads. Benefits: • No gen-set oversizing • Small cable/fuses/breakers size • No extra heating of transformers Unique electrical performance Reduced TCO www.newaveups.com 02.02.2011 8 Features and performance Efficiency Flat Efficiency Graph Results in low losses at PARTIAL and FULL load Redundant UPS Systems operating typically at 25-75% of the rated load. Energy Savings Reduced TCO www.newaveups.com 02.02.2011 9 Mechanical Construction Overview: Cabinet A LCD Display Air inlets • SNMP Card • Pot.free output contacts (optional) • RS232 • Pot.free Input contacts • Multidrop Parallel kit By-pass fuse Battery fuse Rectifier fuse Castors Manual By-pass UPS disconnect I/O connection www.newaveups.com 02.02.2011 10 Mechanical Construction Overview: Cabinet A Display Board CPU board • Rectifier • Booster • Battery charger •Inverter Battery bank www.newaveups.com 02.02.2011 11 Mechanical Construction Overview: Cabinet B LCD Display • SNMPCard • Pot.free output contacts (optional) • RS232 • Pot.free Input contacts • Multidrop Parallel Kit Air inlets Battery fuse By-pass fuse Rectifier fuse Manual By-pass Castors UPS disconnect I/O connection www.newaveups.com 02.02.2011 12 Mechanical Construciton Overview: Cabinet B Display Board CPU board • Rectifier • Booster • Battery charger •Inverter Battery bank www.newaveups.com 02.02.2011 13 Mechanical Construciton Overview: Cabinet C LCD Display Removeable Front Panel No Access from Rear Side Air inlets Castors www.newaveups.com 02.02.2011 14 Mechanical Construciton Overview: Cabinet C RS 232 Pot.free Input Contacts Multidrop Parall. Kit • SNMP • Card and Pot. Free output contacts (optional) Rectifier fuse By-pass fuse Battery fuse Manual By-pass UPS disconnect I/O connection www.newaveups.com 02.02.2011 15 Battery Configuration Battery shelves, trays and links Type A Type B Type C Power Range kVA/kW 10/9 15/13.5 20/18 10/9 15/13.5 20/18 25/22.5 25/22.5 30/27 40/36 50/45 Maximum Battery Capacity 1 x 48 x 7/9Ah 2 x 48 x 7/9Ah 3 x 48 x 7/9Ah 1 x 48 x 28Ah Battery shelves and trays Included Included Optional: Battery links Optional: Optional: Optional: 1 x 48 x 7/9Ah 04-0136 1 x 48 x 7/9Ah 04-0136 2 x 48 x 7/9Ah 04-0150 2 x 48 x 7/9Ah 04-1473 3 x 48 x 7/9Ah 04-1472 1 x 48 x 28Ah 04-1474 2 x 48 x 7/9Ah 04-1475 3 x 48 x 7/9Ah 04-1476 1 x 48 x 28Ah 04-1477 www.newaveups.com 02.02.2011 16 Battery Configuration Battery shelves & trays Cabinet C (25, 30,40,50kVA) Standard Cabinet C 2 Shelves are delivered with the empty cabinet Additional Shelves and Trays are OPTIONAL. Possible configurations: • 2 x 48 x 7/9Ah • 3 x 48 x 7/9Ah • 1 x 48 x 28Ah Shelves (Standard) www.newaveups.com 02.02.2011 17 Battery Configuration Battery shelves & trays Cabinet C (25, 30,40,50kVA) OPTION 04-1475: Battery shelves and trays for 2 x 48 x 7/9Ah Kit consisting of: 2 x shelves 16 x trays (6 x 7/9Ah batt / tray) www.newaveups.com 02.02.2011 18 Battery Configuration Battery shelves & trays Cabinet C (25, 30,40,50kVA) OPTION 04-1476: Battery shelves and trays for 3 x 48 x 7/9Ah Kit consisting of: 4 x shelves 24 x trays (6 x 7/9Ah batt / tray) www.newaveups.com 02.02.2011 19 Battery Configuration Battery shelves & trays Cabinet C (25, 30,40,50kVA) OPTION 04-1477: Battery shelves and trays for 1 x 48 x 28Ah Kit consisting of: 2 x shelves 16 x trays (3 x 28Ah batt / tray) www.newaveups.com 02.02.2011 20 Battery Configuration Caracteristics (1) Source: PowerScale Product Specifications Doc: 04-1206_S10_NW_TDSPS_10-50kVA_GB_101021 (2) www.newaveups.com 02.02.2011 21 Battery Configuration Caracteristics (2) www.newaveups.com 02.02.2011 22 Battery Configuration How to order INTEGRATED Batteries from Newave Type of Batteries offered by Newave SA 7Ah: Panasonic (normal life) 9Ah: YUASA (normal life) 28Ah: Panasonic (long life 10Y) Principles: 1. Subsidiaries and Partners calculate the exact number of battery per string that the application requests and order number of blocks accordingly (minimal number acc to Product Specifications) 2. Newave delivers the UPS with integrated batteries mounted and tested, as requested 3. Battery blocks in PowerScale price list include shelves, trays and battery links (items 04-1203; 04-1204; 04-1472; 041473; 04-1474) PO-Form detail Set Battery Autonomy: mins. Number of Battery Strings: Number of Battery Blocks: (per string) Ah: www.newaveups.com 02.02.2011 23 Battery Configuration Autonomy Table 10kVA Powerscale 10kVA, 9kW Autonomy (min) 6 8 10 12 15 18 20 22 25 30 35 40 60 Min. Nr of Batt Cab A Min. Nr of Batt Cab B Load Power 6kW 8kW 9kW 7Ah batt 9Ah batt 7Ah batt 9Ah batt 7Ah batt 9Ah batt 1 x 24 1 x 20 1 x 32 1 x 22 1 x 34 1 x 24 1 x 28 1 x 22 1 x 38 1 x 26 1 x 42 1 x 28 1 x 32 1 x 24 1 x 46 1 x 32 1 x 48 1 x 34 1 x 40 1 x 28 2 x 26 1 x 36 2 x 30 1 x 40 1 x 48 1 x 32 2 x 32 1 x 42 2 x 36 1 x 48 2 x 28 1 x 38 2 x 36 1 x 48 2 x 40 2 x 28 2 x 30 1 x 40 2 x 40 2 x 28 2 x 44 2 x 30 2 x 32 1 x 44 2 x 42 2 x 30 2 x 48 2 x 32 2 x 36 1 x 48 2 x 48 2 x 32 n.a. 2 x 36 2 x 40 2 x 28 n.a. 2 x 38 n.a. 2 x 42 2 x 46 2 x 32 n.a. 2 x 42 n.a. 2 x 48 n.a. 2 x 36 n.a. 2 x 48 n.a. n.a. n.a. 2 x 48 n.a. n.a. n.a. n.a. 16 blocks 20 blocks 24 blocks 16 blocks 20 blocks 24 blocks Cabinet A: max 1 x 48 x 7/9Ah batteries Cabinet B: max 2 x 48 x 7/9Ah batteries Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc. www.newaveups.com 02.02.2011 24 Battery Configuration Autonomy Table 15kVA Powerscale 15kVA, 13.5kW Autonomy (min) 6 8 10 12 15 18 20 25 30 35 40 60 Min. Nr of Batt Cab A Min. Nr of Batt Cab B 10kW 7Ah batt 9Ah batt 1 x 40 1 x 28 1 x 48 1 x 34 2 x 28 1 x 40 2 x 34 1 x 48 2 x 40 2 x 28 2 x 46 2 x 32 2 x 48 2 x 36 n.a. 2 x 40 n.a. 2 x 48 n.a. n.a. n.a. n.a. n.a. n.a. 24 blocks 24 blocks Load Power 12kW 7Ah batt 9Ah batt 1 x 48 1 x 32 2 x 28 1 x 40 2 x 34 1 x 48 2 x 40 2 x 28 2 x 48 2 x 32 n.a. 2 x 38 n.a. 2 x 40 n.a. 2 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 30 blocks 30 blocks 13.5kW 7Ah batt 9Ah batt 1 x 34 2 x 34 1 x 42 2 x 40 1 x 48 2 x 48 n.a. 2 x 34 n.a. 2 x 42 n.a. 2 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 34 blocks 34 blocks Cabinet A: max 1 x 48 x 7/9Ah batteries Cabinet B: max 2 x 48 x 7/9Ah batteries Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc. www.newaveups.com 02.02.2011 25 Battery Configuration Autonomy Table 20kVA Powerscale 20kVA, 18kW Autonomy (min) 4 6 7 8 10 11 12 15 17 18 20 25 30 35 Min. Nr of Batt Cab A Min. Nr of Batt Cab B 12kW 7Ah batt 9Ah batt 1 x 48 1 x 32 2 x 28 2 x 34 1 x 40 1 x 48 2 x 40 2 x 28 2 x 48 2 x 32 n.a. n.a. 2 x 38 n.a. 2 x 40 n.a. 2 x 48 n.a. n.a. n.a. n.a. 30 blocks 24 blocks Load Power 16kW 7Ah batt 9Ah batt 1 x 48 2 x 32 1 x 44 1 x 48 2 x 38 2 x 46 2 x 32 2 x 48 n.a. 2 x 36 n.a. 2 x 42 n.a. 2 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 40 blocks 32 blocks 18kW 7Ah batt 9Ah batt 2 x 36 1 x 46 2 x 38 2 x 42 2 x 48 2 x 36 n.a. 2 x 38 n.a. 2 x 40 n.a. 2 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 46 blocks 36 blocks Cabinet A: max 1 x 48 x 7/9Ah batteries Cabinet B: max 2 x 48 x 7/9Ah batteries Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc. www.newaveups.com 02.02.2011 26 Battery Configuration Autonomy Table 25kVA Powerscale 25kVA, 22.5kW Autonomy (min) 6 8 10 12 13 15 18 20 22 24 25 27 28 29 31 32 Min. Nr of Batt Cab B Min. Nr of Batt Cab C Load Power 16kW 20kW 7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt 2 x 32 1 x 44 2 x 40 2 x 40** 2 x 38 1 x 48 2 x 48 2 x 40** 2 x 46 2 x 32 3 x 40** 2 x 40 2 x 48 2 x 36 3 x 44 2 x 44 3 x 48 2 x 48 3 x 42 2 x 44 n.a. 3 x 40** 3 x 48 2 x 48 1 x 34 n.a. 3 x 42 1 x 40 n.a. 3 x 36 n.a. 3 x 46 n.a. 3 x 38 1 x 40 n.a. 3 x 48 1 x 48 n.a. n.a. n.a. n.a. n.a. 3 x 42 1 x 44 n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 32 blocks 40 blocks 32 blocks 40 blocks 7Ah batt 2 x 46 2 x 48 3 x 46 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 22.5kW 9Ah batt 28Ah batt 2 x 46 2 x 48 3 x 46 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 46 blocks 46 blocks 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. Cabinet B: max 2 x 48 x 7/9Ah batteries Cabinet C: max 3 x 48 x 7/9Ah batteries Note: Backup times are approximate and may vary with battery type, configuration, battery age, temperature etc. www.newaveups.com 02.02.2011 27 Battery Configuration Autonomy Table 30kVA Powerscale 30kVA, 27kW Autonomy (min) 6 7 8 10 12 13 15 18 20 22 24 25 27 28 29 31 32 Min. Nr of Batt Cab C 7Ah batt 2 x 40 Load Power 20kW 24kW 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt 2 x 48 7Ah batt 3 x 36 2 x 48 3 x 44 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 27kW 9Ah batt 28Ah batt 3 x 28 2 x 40 2 x 44 2 x 48 3 x 42 3 x 46 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. 20 blocks 2 x 48 1 x 40 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 24 blocks 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 28 blocks 1 x 28 1 x 30 1 x 36 1 x 42 1 x 44 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. Cabinet C: max 3 x 48 x 7/9Ah batteries www.newaveups.com 02.02.2011 28 Battery Configuration Autonomy Table 40kVA Powerscale 40kVA, 36kW Autonomy (min) 6 7 8 9 10 12 13 15 16 18 20 Min. Nr of Batt Cab C Load Power 25kW 32kW 7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt 2 x 48 2 x 32 2 x 48 1 x 26 3 x 48 1 x 32 3 x 40 2 x 40 n.a. 1 x 34 n.a. 3 x 48 2 x 48 1 x 34 n.a. 1 x 40 n.a. 3 x 38 n.a. 3 x 48 1 x 48 n.a. 3 x 40 1 x 40 n.a. n.a. n.a. n.a. 3 x 44 n.a. n.a. n.a. n.a. 3 x 48 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 26 blocks 32 blocks 36kW 7Ah batt 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 9Ah batt 28Ah batt 2 x 48 3 x 36 1 x 36 1 x 42 3 x 46 1 x 44 3 x 48 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 36 blocks Cabinet C: max 3 x 48 x 7/9Ah batteries www.newaveups.com 02.02.2011 29 Battery Configuration Autonomy Table 50kVA Powerscale 50kVA, 40kW Autonomy (min) 6 7 8 9 10 12 13 15 16 18 20 Min. Nr of Batt Cab C Load Power 35kW 40kW 7Ah batt 9Ah batt 28Ah batt 7Ah batt 9Ah batt 28Ah batt 3 x 48 2 x 48 1 x 34 n.a. n.a. n.a. 3 x 40 1 x 40 n.a. 3 x 40 1 x 40 n.a. 3 x 44 n.a. n.a. 3 x 48 1 x 48 n.a. 3 x 44 1 x 48 n.a. n.a. n.a. n.a. 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 34 blocks 40 blocks 45kW 7Ah batt n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 9Ah batt 28Ah batt 3 x 46 3 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. 44 blocks 1 x 44 1 x 48 n.a. n.a. n.a. n.a. n.a. n.a. n.a. n.a. Cabinet C: max 3 x 48 x 7/9Ah batteries www.newaveups.com 02.02.2011 30 External Batteries – Battery Cabinet Battery Cabinet In case of external battery requirment, an external battery cabinet will be made available in March 2011. More information will be available early 2011 www.newaveups.com 02.02.2011 31 Connectivity Standard - included Optional • RS232 on Sub-D9 port A. SNMP/USHA Card (Slot) • Input Dry Contacts: 1. 2. 3. 4. 5. Remote shut down Generator ON Programable Input: Customer IN1 Temp Sensor for Battery 12VDC Source • RJ 45 for Multidrop B. Optional Card (Dry contact and USB port: Item nr 00-9737) • Output Dry Contacts: 1.Common Alarm 2.Load on Bypass 3.Battery low 4.Load on Inverster 5.Mains Failure • USB port www.newaveups.com 02.02.2011 32 Options and Accessories Available in price list SNMP slot card (web enabled) Shutdown software Potential free output contact slot card, including USB port Parallel kit (one additionnel PCB + one parallel adapter) Parallel cables of different lenghts Back feed protection Temperature probe On special request Emergency Shut Down I/O Transformer for galvanic isolation or voltage adaptation, special I/O configuration www.newaveups.com 02.02.2011 33 Sales Availability Ex Works Availability 10kVA Cabinet 15kVA Cabinet 20kVA Cabinet 25kVA Cabinet 25kVA 30,40,50kVA Battery Cabinet A and B A and B A and B B Cabinet C Cabinet C January 2011 March 2011 Documentation 1. 2. 3. 4. 5. 6. Sales Presentation Product Flyer Technical Specifications Price List PO-Form User Manual (at delivery) www.newaveups.com 02.02.2011 34 www.newaveups.com 02.02.2011 35