Offsite Disaster Recovery Solution – PT2015/18

advertisement
Offsite Disaster Recovery Solution – PT2015/18
14-07-2015
Open and Welcome
Procurement Process
• Mandatory requirements
• Response templates
• Interaction with UNISA
Tender Overview
Current Environment
• Network
• Science campus Data Centre
• Core systems
Questions and Answers Session
Mandatory Requirements
The following documentation must be submitted, failure to comply and submit any
one of the documents will disqualify the submission:
Annexure A1:
Proof of attendance of compulsory information session
Annexure A2:
Completed and signed Supplier List Application Form (F25)
Annexure A3:
Resolution to sign on behalf of the tendering unit
Annexure A4:
Current and valid original SARS Clearance Certificate
Annexure A5:
Copy of company registration documents indicating list of
shareholders / members from CIPC / CIPRO
Annexure A6:
Pricing template.
Annexure A7:
Minimum of three recent (not older than five (5) years from the
date of the submission) contactable references from customers to
which the tenderer has provided or is providing goods/services that
are substantially similar to the goods/service required.
Mandatory Requirements
Annexure A8:
Financial Statements
i. One set (2 years comparative figures) of the most recent
audited financial statements for companies or financial
statements signed by the accounting officer for close
corporations
ii. Where the financial statements of the holding company are
submitted, a signed letter be included from the holding
company that they would be liable if the subsidiary defaulted.
Failure to submit such a letter will disqualify the tender
submission
iii. The financial statements should be submitted as a separate
bound document
Annexure A9:
Response template must be completed in full.
Annexure A10:
The bidders DR site must be a minimum of Tier / Rate Three (3).
To confirm that the bidder is Tier / Rate three (3) or above, a valid
copy of certification must be provided by either Uptime Institute, or
ANSI/TIA
Note: All electronic responses are to be submitted in Microsoft Excel / Word format,
PDF documents will not be allowed.
ICT has a mandate to ensure that UNISA will be able to recover
its data in the event of a disaster.
The project seeks a three year contract with a service provider
capable of meeting UNISA’s requirements to provide either a Hot
site or a Cold site for recovery.
The Objectives are:
• Provide a DR solution at a TIER 3 location outside Gauteng
• Provide suggested RTO and RPO per solution
• Insurance that none of UNISA’s data will leave South African
boarders
• UNISA anticipates conducting two tests per year
• Provide work area recovery for ICT Emergency Response
Team
Network
Rack layout at Science Campus Data Centre.
Dell Equipment
Science Campus Data Centre.
Oracle Exadata
IBM Storage devices
IBM server and storage
Hardware requirements for UNISA’s Core Systems.
Nr of servers
CPU's
Memory
Storage used
MyUnisa
84
308
1.18TB
21.4TB
Millennium
3
28
76GB
1.2TB
AD
16
46
900GB
3.75TB
Exchange
7
40
896GB
5.1TB
Uniflow
4
32
14GB
1TB
Maximo
2
14
64GB
360Gb
Commvault
2
Exadata
(MyUnisa
/
Student System /
Databases / EBS) ¼ Rack
2
64GB
46TB
Standard
Standard
105TB
IBM (Application)
8
100GB
20TB
1
Q&A
Closing date:
29 July 2015
The following questions were asked:
1. Value of the KIT to be relocated?
R30 million
2. Weight of KIT per rack?
Exadata = 380Kg
IBM tape library = 200Kg
IBM storage = 400Kg
Dell = between 300Kg and 400Kg for the 3 racks
3. SANRen POPs?
Contact TENET 021 763 7147
4. Workspace for the ICT Emergency response team
Space needed for 20 Unisa ICT staff which will visit the
site in the event of a disaster or DR test
Thank You !