SITE MANAGEMENT & HYBRID POWER SYSTEM THE NEXT STEP TOWARDS A GREENER FOOTPRINT FOR YOUR NETWORK Presented by Dawie De Villiers • Inala Technologies was founded out of the Telecoms industry in 1996; • A supplier of choice for all broadcast, test, measurement & monitoring requirements; • Positioned in Midrand, Stellenbosch and Durban with a staff complement of 100 • Superior BEE credentials SITE MANAGEMENT & HYBRID POWER SYSTEM ABOUT INALA Inala’s SAM2 is a new concept of remote power management that allows the operator to fully manage and maintain its network infrastructure remotely. It provides the ability to monitor all power related issues including but not limited to: • • • • • • • Generator control Battery Management Utility Grid Power Management DC Reduced Energy Cooling (REC) Fuel Management - Fuel levels and accurate consumption Highlights any anomalies with excessive usage (theft!!) The ability to identify problematic sites before deploying field staff Avoids unnecessary call outs SITE MANAGEMENT & HYBRID POWER SYSTEM OPEX REDUCTION SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK SYSTEM DIAGRAM SITE MANAGEMENT & HYBRID POWER SYSTEM REMOTE COMMUNICATIONS SITE MANAGEMENT & HYBRID POWER SYSTEM REMOTE COMMUNICATIONS Main Control Unit Aircon Control Switch Generator Controller Fuel Probe Water in Diesel Sensor • • • • • • • • • • Main Control Unit Generator Control Unit Water in diesel Probe Aircon Control Switch Navigation Light Monitor Mains/Phase/Frequency Tank Lid Kit Current Probe Fuel Probe Tank Lid Kit Utility Meter Utility Meter NAV Monitor Current Clamp MPF Monitor SITE MANAGEMENT & HYBRID POWER SYSTEM SAM2 - BASIC HARWARE COMPONENTS LED Light and Controller Dual LED Lights NAV Controller Typical Installation SITE MANAGEMENT & HYBRID POWER SYSTEM DC NAVIGATION LIGHT SYSTEM Comprises Of: • Inlet Louver Assembly • Passive Filter • Optional Active Filter • Extractor Ventilation Fan Purpose: • Aircon runtime reduction • Cooling during EPCC • Cabin Constant Regulation • Remote Management Active Electronic Filter Inlet Louver Assembly DC Ventilation Fan Passive Filter Cartridge SITE MANAGEMENT & HYBRID POWER SYSTEM DC REDUCED ENERGY COOLING (REC) BTS MONITORING DOOR SWITCH DOOR/MOVE BYPASS BTS CONTROL SAM2 AC SWITCH UNIT AC 1, 2, 3 & 4 MOTION SENSOR GEN CONTROL UNIT GEN 1&2 GEN REMOTE MANAGEMENT SMOKE DETECTOR FUEL CELL ALARM MONITORING FUEL CELL REMOTE TCP/IP MANAGEMENT PERIMETER SECURITY RECTIFIER ALARM MONITORING RECTIFIER REMOTE RS232 MANAGEMENT PANIC BUTTON BATTERY MANAGEMENT ACCESS CONTROL HYBRID POWER CONTROL TEMP: ROOM AC 1,2,3, 4 & ODT HUMIDITY SENSOR 1 & 2 LCD REC , DC FAN UNIT KEYPAD MPF MONITOR RS232 1 X RD232 PORT NAV MONITOR RS485 3 X RS485 PORT RECTIFIER ALARMS TCP/IP 24 X RBS EXT ALARMS GENERATOR ALARMS POWER UTILITY METER BATTER MON VOLTS & CURRENT 38 DIGITAL I/P’S 7 ANALOG I/P’S DC SUPPLY 12/24/48 VDC ELECTROSTATIC FILTER SITE MANAGEMENT & HYBRID POWER SYSTEM SYSTEM REFERENCE MODEL SAM2 Generator Controller SAM2 Controller Multi-Pair Tie-Cable Multi-Pair Tie-Cable SITE MANAGEMENT & HYBRID POWER SYSTEM MASTER SLAVE FAILSAFE CONTROL SITE MANAGEMENT & HYBRID POWER SYSTEM MAIN CONTROLLER CABLE TERMINATION UNIT SITE MANAGEMENT & HYBRID POWER SYSTEM DOOR SENSORS SITE MANAGEMENT & HYBRID POWER SYSTEM INDOOR MOVEMENT SENSOR SITE MANAGEMENT & HYBRID POWER SYSTEM SMOKE SENSOR SITE MANAGEMENT & HYBRID POWER SYSTEM ROOM TEMPERATURE AND HUMIDITY SENSOR SITE MANAGEMENT & HYBRID POWER SYSTEM AIRCON CONTROL SWITCH SITE MANAGEMENT & HYBRID POWER SYSTEM PANIC BUTTON SENSOR SITE MANAGEMENT & HYBRID POWER SYSTEM MAINS PHASE & FREQUENCY MONITOR SITE MANAGEMENT & HYBRID POWER SYSTEM UNIVERSAL NAVIGATION LIGHT MONITOR SITE MANAGEMENT & HYBRID POWER SYSTEM HYBRID CONTROL Monitor Conditions: • Voltage per Phase • Current per Phase • KwH Consumption Utility management: • Statistical Data • Automated Disconnect SITE MANAGEMENT & HYBRID POWER SYSTEM UTILITY GRID SUPPLY MANAGEMENT SITE MANAGEMENT & HYBRID POWER SYSTEM UTILITY METER WIRING Rectifier Monitoring: • • • • Rectifier System Fail Rectifier Module Fail Rectifier Low Volt 1 Rectifier Low Volt 2 Battery Monitoring: • BTS Battery Voltage • Battery Charge Current • Battery Discharge Current SITE MANAGEMENT & HYBRID POWER SYSTEM RECTIFIER & BATTERY MANAGEMENT SITE MANAGEMENT & HYBRID POWER SYSTEM BATTERY CURRENT PROBE SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR MANAGEMENT 1 Monitored Conditions: • • • • • • • • • • • • • • • Generator Running Generator Fault Generator Door Generator Status (Comms) Generator Stop/Start Generator Service Interval Generator Emergency Stop Generator Low Fuel Generator Oil Pressure Generator Over Temperature Generator Battery Voltage Generator Run Hours Generator Swap Cycle Generator/Mains On Load Remote Generator Fault Reset SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR MANAGEMENT 2 Gen Start Fail Alarm Activated – After 4 failed start attempts. Counter Reset Conditions for Gen Start Fail Alarm. • • • • • • • • Generator Remote Start Generator Remote Reset Decreasing BTS Battery Voltage Generator Swap (Manual or Auto) When exiting from EPCC (EPCC Fail) Whenever any enabled EPCC Suspend Input changes state Both generators are OFF due to Utility Mains present and alarm CLEARED When generator is running and there is no Utility Mains alarm 90 seconds thereafter SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR FAIL TO START RESET COUNTER SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR CONTROLLER POWER CONNECTIONS Visible LED indications: • • • • • LED1 – Indicates 12Vdc supply (On= >12Vdc) LED2 – Comms with Main Controller (On = bi-directional comms) LED3 – Mains Supply Output (On – L1-3 output >187Vac) LED4 – Generator 1 Run (On – generator running with mains output) LED5 – Generator 2 Run (On – generator running with mains output) SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR CONTROLLER LED INDICATIONS SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR CONTROLLER CABLE TERMINATION UNIT Fuel Management: • • • • Tank Lid Open/Close Event Fuel Siphoned (removed) Event Fuel Filling (added) Event Analogue Fuel Level Reading • • • • Fuel Level Full Event – e.g. >75% Fuel Level Low Event – e.g. <25% Water In Diesel Event Fuel/Water Probe Fail Event SITE MANAGEMENT & HYBRID POWER SYSTEM FUEL MANAGEMENT Cable Color Code SITE MANAGEMENT & HYBRID POWER SYSTEM FUEL PROBE WIRING Cable Color Code SITE MANAGEMENT & HYBRID POWER SYSTEM BULK FUEL TANK LID KIT WIRING Cable Color Code SITE MANAGEMENT & HYBRID POWER SYSTEM FUEL TANK WATER IN DIESEL PROBE WIRING GEN1 GEN2 SAM2 Controller Utility 230Vac Generator 230Vac Multi-Pair Tie-Cable SAM2_GEN 12Vdc Supply Generator Battery Generator Fault/Alarm Indication Generator Run Indication Generator Door Indication Low Fuel Indication Remote Start SAM2_GEN Remote Fault/Alarm Reset Generator Interconnections for Generator Control & Monitoring 12Vdc SITE MANAGEMENT & HYBRID POWER SYSTEM GENERATOR CONTROL SITE MANAGEMENT & HYBRID POWER SYSTEM INTELILITE AMF20/25 GENERATOR WIRING SAM2_GEN Krone Block Generator Run Generator Fault KB2/3/A KB2/3/B KB2/1/A KB2/1/B Hynex Key Switch +12Vdc Generator Remote Reset Generator Remote Start Generator Door Switch Fuel Tank Lid Switch KB1/9/B KB1/9/A KB1/7/A KB1/7/B KB2/2/a KB2/2/b KB2/4/a KB2/4/b Fuel Tank Level Probe KB1/10/a/b Fuel Tank Water Probe KB3/10/a/b SITE MANAGEMENT & HYBRID POWER SYSTEM SDMO NEXYS GENERATOR WIRING SITE MANAGEMENT & HYBRID POWER SYSTEM MAIN CONTROLLER DC POWER WIRING SITE MANAGEMENT & HYBRID POWER SYSTEM VENTILATION SYSTEM DC POWER WIRING ECT – FRONT PANEL VIEW Hierarchy: • Logical grouping of sites according to region, city, site • Colour coded display of leaf nodes according to alarm severity SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – HIERARCHICAL VIEW Surveillance • Ability to filter and group alarms according to severity • Keep an Audit trail of acknowledged alarms SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – ALARM SURVEILLANCE Alarm View • Availability of complete site alarm information before technician call-out • Alarm history/trending through playback feature • Configurable/Customised alarm severity levels SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – ALARM VIEW Power Distribution • Statistical data of Utility Grid versus Generator versus Hybrid Hours • Data exported in excel format • Visual pie charts on a per site, city or region basis SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – POWER DISTRIBUTION REPORTING Fuel Consumption • Configurable fuel settings part of OPPEX savings report • Calculation based upon generator run hours • Actual or estimated values, based upon trending SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – FUEL CONSUMPTION REPORTING Fuel Siphoning • Configurable fuel siphoning alarm threshold • Data exported in excel format • Visual fuel graphs for easy analysis SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT - FUEL SIPHONING REPORTING Fuel Filling • Configurable fuel filling alarm threshold • Data exported in excel format • Visual fuel graphs for easy analysis SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT - FUEL FILLING REPORTING Hybrid Battery Cycles • Statistical data of Utility Grid versus Generator versus Hybrid Hours • Statistical data of daily Generator hours versus daily Hybrid Hours • Statistical data of Charge/Discharge current versus Battery Voltage SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT - HYBRID BATTERY CYCLES Room Regulating Temperature 33°C Free Cooling activated And room temperature kept at a constant threshold Air Conditioners at high cool to regulate room temperature Reduced Energy Cooling • Statistical data of AC1 versus AC2 versus REC hours • Regulates room temperature during Hybrid cycle • Reduces Aircon activity – less load current, operational costs and service interval SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – REC GRAPHICAL VIEWS Utility Grid Power • Statistical data of Voltage per phase • Statistical data of Load Current per phase • Statistical data of total KwH consumption SITE MANAGEMENT & HYBRID POWER SYSTEM NETWORK MANAGEMENT – UTILITY GRID VIEWS THANK YOU