United Nation Development Program Emergency Water Supply and Rehabilitation Programme PAL 10-00052737 CONSTRUCTION OF TAL EL-SULTAN BOOSTER STATIONSRafah Cost Estimate Center for Engineering and Planning (CEP) & Engineering & Management and Planning (EMCC) BILL NO. 1 CIVIL WORKS Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.1.0 1.1.1 1.1.2 Description Excavation & Concrete Works Excavate for foundations (Pumps room and service building) including removing excavated material from the site to the location approved, all according to Drawings, Specifications and instructions of the Engineer. Backfilling from the selected excavated material Unit Qty. M3 60 M3 40 Unit Price (US$) Total (US$) over and around foundation and to make up levels for the site in layers 25cm thick (M.D.D 98%) according to Eng. instructions and specifications. 1.1.3 Supply and cast ready mix plain concrete B200 below foundations (Pumps room and service building), base and concrete supports for pipes, anchor blocks or others according to Drawings, Specifications and instructions of the Engineer. M3 7.5 1.1.4 Supply and cast ready mix reinforced concrete B300 for foundations (Pumps room and service building), base including reinforcement and shuttering, according to Drawings, Specifications and instructions of the Engineer. M3 30 1.1.5 Supply and cast ready mix reinforced concrete B300 for columns, including reinforcement and shuttering, according to Drawings, Specifications and instructions of the Engineer. M3 8 1.1.6 Supply and cast ready mix reinforced concrete B300 for ground beams including reinforcement and shuttering, according to Drawings, Specifications and instructions of the Engineer. M3 11 1.1.7 Supply and cast ready mix concrete B250 for pumps room Ground Slab of 10m thickness including steel reinforcement ( 10 mm every 15 cm in both directions), and base coarse layer 15cm thick according to Drawings, Specifications and instructions of the Engineer. M2 60 1.1.8 Supply and cast concrete B250 for service building Ground Slab of 10cm thickness including steel reinforcement ( 8 mm every 20 cm in both directions), and base coarse layer 10cm thick, and Nylon sheet according to Drawings, Specifications and instructions of the Engineer. M2 80 2 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.1.9 Description Unit Qty. Supply and cast ready mix concrete B250 for pumps room and service building Ribbed Slabs of 23cm thickness including reinforced steel hollow block (25x40x17cm), drop beams, , and electrical conduits and all other materials according to Drawings, Specifications and instructions of the Engineer. M2 180 1.1.10 Supply and lay one layer of plasticized bitumen roofing membrane with chipping 4 mm thick, the work includes supplying and spreading prime Light weight concrete surface prior to laying with average thickness 8 cm dressing into rain water outlets to form water proofing seal and cover with angle fillets. The rate includes verticals parts skirting as per specification and drawings. M2 200 1.2.0 1.2.1 Block, Plastering & Painting Works Supply and construct walls from hollow concrete blocks, (20x20x40cm) including supplying and casting reinforced concrete B250 for Lintels & Posts all according to Drawings, Specifications and instructions of the Engineer. M2 290 1.2.2 Ditto, but for hollow concrete block (10x20x40cm) M2 10 1.2.3 Supply and make internal plastering 13 mm thick to walls and ceiling, after rough primer nail rendering works include all material needed according to technical specifications. M2 450 1.2.4 Supply materials and make external plastering two faces and final face with tyrolean plaster including two coats of emulsion paints (Supercryl) all according to Drawings, Specifications and instructions of the Engineer. Supply materials and make emulsion paint (Supercryl) two coats and base coat for all internal walls and ceiling, all according to Drawings, Specifications and instructions of the Engineer. M2 270 M2 450 1.2.5 1.3.0 Unit Price (US$) Total (US$) Metal Works 3 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.3.1 Description Unit Qty. Supply and install galvanized metal door 200x 450 cm (type D1) with new double sheet (2-mm) complete with frame, ironmongery, ventilation louvers for pumps room. The price should include painting with two coats and base coat and union or equivalent type lock all according to Drawings, Specifications and instructions of the Engineer. No. 1 1.3.2 Supply and install galvanized metal door 160x 220 m (type D2) with new double sheet (2-mm) complete with frame, ironmongery, for service building. The price should include painting with two coats and base coat and union type lock or equivalent, all according to Drawings, Specifications and instructions of the Engineer. No. 2 1.3.3 Ditto, but 90x220 cm (type D3). No. 2 1.3.4 Ditto, but 80x220 cm (type D4). No. 1 1.3.5 Supply and install galvanized metal window 120x140cm (type W1) with ventilation louvers for pumps room and service building. The price should include painting with two coats and base coat, all according to Drawings, Specifications and instructions of the Engineer. No. 6 1.3.6 Ditto, but 80x60cm (type W2). No. 1 1.3.7 Ditto, but 100x200cm (type W3). No. 3 1.3.8 Supply and fix colored aluminum window Kalil Type7000 or equivalent size 120X140 cm (type W4), two sliding leave complete with one sliding fly screen leaf, frame, clear glass 4mm thick, all according to Drawings, Specifications and instructions of the Engineer. No. 2 1.3.9 Supply and fix steel protection grate for window overall size100x200cm for window type (W4). The price should include painting with two coats and base coat, all according to Drawings, Specifications and instructions of the Engineer. No. 2 1.3.10 Supply and install galvanized steel ladder all according to Drawings, Specifications and instructions of the Engineer. The price should include painting with two coats and base coat, all according to Drawings, Specifications and instructions of the Engineer. No. 1 1.4.0 Tiling Works 4 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.4.1 Description Unit Qty. Supply and install terrazzo floor tiles size 25x25x2.5cm for service building. The price should include 2.5cm mortar bed and 5cm thick sand bed, terrazzo skirting of same kind color of the floor tiles size 25x7x1cm thick laid on 1cm mortar backing, all according to Drawings, Specifications and instructions of the Engineer. M2 60 1.4.3 Supply and install non-slipping white ceramic floor tiles size 20x20x0.8 cm. The price should include 2.5cm mortar bed and 5cm thick sand bed, all according to Drawings, Specifications and instructions of the Engineer. M2 15 1.4.2 Supply and install white glazed wall tiles size 20x20x0.6 cm. The price should include mortar backing up to lintel level, all according to Drawings, Specifications and instructions of the Engineer. M2 40 1.4.3 Supply and install local marble size 25cm x 3cm thick for window sills, doors including 2.5cm mortar bed, all according to Drawings, Specifications and instructions of the Engineer. LM 27 1.4.4 Supply and erect marble 3 cm thick for cupboards 60 cm wide and 90 cm high including vertical dividers, internal horizontal shelves, back of cupboards, floors and granite (Tiger eye) for the top surface with round edges, skirting 10 cm high and making the needed opening for basins as shown in drawings. L.S 1 1.4.5 Supply, spread, level and compact of 40cm thick of approved selected material (Kurkar) type A to be spread & compacted on layers 20cm to get {98%M.D.D) prior to subsequent interlock tiling including soil grading leveling as per specifications and drawings. M3 270 1.4.6 Supply & cast ready mix concrete B250 kg/cm2 chamfered edge beam 15x20 for interlock tiling as per specifications and drawings. M3 2 1.4.7 Supply, spread, land, interlock tiles size 8x10x20cm price includes 5 cm clean sand as per specification and drawing. M2 650 1.5.0 Plumping Works 5 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.5.1 Description Unit Qty. Supply, and install. Vitreous China, European type W.C. First Class size (48x36x40cm), completed with 2 Gallon capacity flush reservoir, china roll holder, chrome plated angle valves and flexible connections, supports, welding, hand spray with flexible chrome connection and all necessary fittings, waste pipes diameters 4", thickness 3.2mm connected to the nearest riser, heavy duty cover, rubber connector on WC outlet to the drain pipes. No. 1 1.5.2 Supply, install, test and commission Vitreous China wash basin (51x38cm), First Class, completed with chrome plated mixer, bottle trap, soap tray, chrome plated angle valves, flexible tubes, wall fixed mirror and all accessories, waste pipes d 2", connected to the nearest floor drain, fittings, supports and hangers. No. 2 1.5.3 Supply and install white fire clay sink Harza Type or equivalent size 54x42 cm including trapped waste fittings, plug and chain, steel brackets supports and the drainage line to the floor trap, chromium plated water tap 1/2" diameter Hamat type or equivalent including cold water supply lines 1/2" dia., all according to Drawings, Specifications and instructions of the Engineer. No. 1 1.5.4 Supply and install white glazed fire clay squatting WC suite (Asiatic WC) complete with flushing cistern, 4" dia. UPVC drainage pipe to the nearest Manhole and white glazed toilet paper holder, chromium plated water pillar valve 1/2" dia including 1/2" water supply pipe and 100cm long rubber hose inside the toilet, all according to Drawings, Specifications and instructions of the Engineer. No. 1 1.5.5 Supply and install 4/2” PVC floor drain including 4” PVC pipe to nearest manhole all according to Drawings, Specifications and instructions of the Engineer. L.S. 2 1.5.6 Supply and install 60cm concrete manhole complete including all necessary works all according to Drawings, Specifications and instructions of the Engineer. No. 2 6 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 1.5.7 Description Unit Qty. Supply and install 100cm internal diameter precast circular reinforced concrete sewage manholes complete with reinforced concrete base, cast iron cover (25 tons capacity), frame and rings, The item also includes B300 benching, shuttering, inside cast-iron steps each step 30 cm maximum and safety measures, excavation in any type of soil to any depth, plain concrete, two external bitumen coating, internal epoxy coating, and backfilling in layers 25 cm maximum using suitable material with watering, and compaction the price includes repairing the damage of the existing asphalt layers, base course layers, curb stone, side walks tiles to the original condition. as described in Specifications and as shown in Drawings and directed by the Engineer No. 2 1.5.8 Supply and install 3” PVC drainage pipes including all necessary bends connections and making good, all according to Drawings, Specifications and instructions of the Engineer. LM 18 1.5.9 Supply and fix 3/4" dia. Galvanized steel water supply pipes from the fire hydrant feeder to the service building roof top tank and from the tank to toilet fixtures and pumps room fixture and including valves, jointing and fittings, all according to Drawings, Specifications and instructions of the Engineer. L.S. 1 1.5.10 Supply and install plastic water storage tank 1 M3 capacity complete with lockable cover, float valve 1/2" dia., cleaning opening with plug 3/4" dia., overflow pipe 3/4" dia., steel base and the connection with the feeding and distribution lines, all according to Drawings, Specifications and instructions of the Engineer. Supply and lay 4" UPVC sewage pipes including excavation, bedding, jointing, backfilling, Asphalt reinstatement testing and connect to the municipal sewage system, all according to Drawings, Specifications and instructions of the Engineer. L.S. 1 LM 35 Supply and lay 8" UPVC, SN-8 sewage pipes including excavation, bedding, jointing, backfilling, Asphalt reinstatement testing and connect to the municipal sewage system, all according to Drawings, Specifications and instructions of the Engineer. L.M 80 1.5.11 1.5.12 Unit Price (US$) Total (US$) Total Carried to Summary (Bill No. 1) 7 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah BILL NO. 2 MECHANICAL WORKS 8 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty Unit Price (US$) Total (US$) Notes: *All the following notes are on the contractor expense: The Contractor shall, when pricing this Bill, take into consideration all costs or expenses of all requirements stipulated in the section entitled “General and Preambles” preceding this Bill. The exact lengths of the required pipes, the exact number of the required valves will be determined during the implementation of the Works. All the works should be done by coordination with the municipality water department. Submission of shop drawing to be approved by the Engineer before starting any work activity. Making trial pits for identifying existing services, connecting existing water pipelines if required. Excavation at any depth in any kind of soil at indicated trench depth. Removal and transport at any distance of excess or unsuitable materials to approved landfill. Repair any damage of any service at full satisfaction of relevant Service Authority. Restoring the existing surface to original status and approval of the Engineer. Testing, flushing and disinfections of the new pipeline. All works should be executed in accordance to drawings, specifications and as instructed by the Engineer. Any cut of asphalt layers must be by using special saw and restoring the asphalt by using two layers of 15 cm (each) base coarse and one layer of asphalt 6 cm thick. 2.1 Buried Pipes Supply and install underground pipelines complete but not limited to following: excavation in all types of soil and disposal of excess material to locations acceptable to the Engineer, bedding, pipe laying 9 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty Unit Price (US$) Total (US$) including all piping works such as welding, cutting and shaping, supplying and installing all kinds of fittings (flanges and blind flanges, etc.), testing, bedding material surround the pipe, backfilling and compaction, disinfection and reinstatement, complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. 2.1.1 18” diameter X 3/16” thickness Steel pipes coated externally with Epoxy primer and two layers of extruded polyethylene coating and internal cement mortar lining (Suction side of PS-7 Booster Station). LM 20 2.1.2 Ditto, but 14” diameter (Discharge side of PS-7 Booster Pumps). LM 26 2.1.3 Ditto, but 12” diameter (Suction and Discharge sides of PS-6 Booster Pumps). LM 28 2.1.4 Ditto, but 10” diameter (Suction sides of PS-7 and PS-6 Booster Pumps). LM 4 2.1.5 4'' diameter X 5/32'' thickness Steel pipes coated externally with Epoxy primer and two layers of extruded polyethylene coating and internal cement mortar lining (Feeder of fire hydrant). Non-Buried Pipes Supply and install pipelines complete including but not limited to: pipe laying including all piping works such as welding, cutting and shaping, supplying and flanges, testing, disinfection and supports including concrete bases, complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. LM 15 2.2.1 14” diameter X 3/16” thickness Steel pipes coated externally with Epoxy coating and internal cement mortar lining (Discharge side of PS-7 Booster Pumps). LM 6 2.2.2 12” diameter X 3/16” thickness Steel pipes coated externally with Epoxy coating and internal cement mortar lining (Discharge side of PS-6 Booster Pumps). LM 6 3.2.3 10” diameter X 3/16” thickness Steel pipes coated externally with Epoxy coating and internal cement mortar lining (Suction side of PS-7 Booster Pumps). LM 9 2.2.4 Ditto, but 10” diameter (Suction side of PS-6 Booster Pumps). LM 6 2.2 10 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 2.3 Description Unit Qty No. 1 Unit Price (US$) Total (US$) Valves in Chambers Supply and install valves in chambers complete including but not limited to the following: excavation in all types of soil, reinforced concrete chamber, chamber cover and ring, and pipe connections, valve, fittings, flanged coupling, bolts, gaskets, concrete support, concrete paving, backfilling and compaction and reinstatement, complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. 2.3.1 2.4 Butterfly Valve, 18'' – PN 16 bar (Suction line of PS-7 & PS-6 Booster Stations). Non- Buried Valves Supply and install valves complete including but not limited to the following: valves, fittings, fixed, jack and concrete supports, complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. 2.4.1 Gate Valve, 10'' – PN 16 bar (Suction and Discharge lines of PS-7 Booster Pumps). No. 6 2.4.2 Gate Valve, 10'' – PN 16 bar (Suction and Discharge lines of PS-6 Booster Pumps). No. 4 2.4.3 Check Valve, ARI or equivalent, 10'' – PN 16 bar (Discharge lines of PS-7 Booster Pumps). No. 3 2.4.4 Check Valve, ARI or equivalent, 10'' – PN 16 bar (Discharge lines of PS-6 Booster Pumps). No. 2 2.4.5 Air Release and Vacuum Release Valve, 80 mm, PN 10 bar, ARI or equivalent, with the 80 diameter Arca bronze gate valve or equivalent connected to it with drain pipe and all accessories required – (Discharge side of PS-7 Booster Pumps). No. 1 2.4.6 Air Release and Vacuum Release Valve, 80 mm, PN 10 bar, ARI or equivalent, with the 80 diameter Arca bronze gate valve or equivalent connected to it and with all accessories required – (Discharge side of PS-6 Booster Pumps). No. 1 2.5 Fittings and Others Supply and install Fittings, Tees and Bends, Reducers, Increasers, Couplings, Expansion Joints, 11 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty Unit Price (US$) Total (US$) and gauges complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. 2.5.1 Supply and install buried 18"x18'' steel tee with external extruded polyethylene coating and internal cement mortar lining factory made (Suction side of PS-7 & PS-6 Booster Stations). No. 2 2.5.2 Ditto, but 18"x10'' (Suction side of PS-7 Booster Station). No. 3 2.5.3 Ditto, but 12"x10'' (Suction side of PS-6 Booster Station). No. 2 2.5.4 Ditto, but 14"x4'' (For fire hydrant feeder) No. 1 2.5.5 Ditto, but flanged 10"x14'' (Discharge side of PS-7 Booster Station). No. 3 2.5.6 Ditto, but flanged 14"x14'' (Discharge side of PS-7 Booster Station). No. 1 2.5.7 Ditto, but flanged 10"x12'' (Discharge side of PS-6 Booster Station). No. 2 2.5.8 Ditto, but flanged 12"x12'' (Discharge side of PS-6 Booster Station). No. 1 2.5.9 Supply and install 18''x12'' concentric steel reducer with external extruded polyethylene coating and internal cement lining factory made (Suction Side of PS-6 Booster Station and Pump Station Bypass). No. 2 2.5.10 Supply and install 10''x5'' eccentric flanged steel reducer with external epoxy coating and internal cement lining factory made (Suction lines of PS-7 Booster Pumps). Ditto, but 10''x6'' (Suction lines of PS-6 Booster Pumps). No. 3 No. 2 2.5.12 Supply and install 4''x10'' concentric flanged steel increaser with external epoxy coating and internal cement lining factory made to fit outlet of pump flange (Discharge lines of PS-7 Booster Pumps). No. 3 2.5.13 Ditto, but 5''x10'' (Discharge lines of PS-6 Booster Pumps). No. 2 2.5.14 Supply and install 10” diameter complete flanged coupling (Suction & Discharge lines of PS-7 Booster Pumps). No. 6 2.5.11 12 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty 2.5.15 Supply and install 10” diameter complete flanged coupling (Suction & Discharge lines of PS-6 Booster Pumps). No. 4 2.5.16 Supply and install 10” diameter complete flexible joint coupling (Discharge lines of PS-7 Booster Pumps). No. 3 2.5.17 Supply and install 10” diameter complete flexible joint coupling (Discharge lines of PS-6 Booster Pumps). No. 2 2.5.18 Supply and install buried 18'' steel 90o elbow with external extruded polyethylene coating and internal cement mortar lining factory made (Suction side of PS-7 & PS-6 Booster Stations). No. 1 2.5.19 Ditto, but 14'' steel 45o (Discharge side of PS-7 Booster Pumps). No. 1 2.5.20 Ditto, but 12'' steel 45o (Discharge side of PS-6 Booster Pumps). No. 1 2.5.21 Supply and install non-buried 10'' steel 90o flanged elbow with external epoxy coating and internal cement mortar lining factory made (Suction lines of PS-7 Booster Station). No. 3 2.5.22 Ditto, but for (Suction lines of PS-6 Booster Station). No. 2 2.5.23 Ditto, but 14'' steel 45o (Discharge side of PS-7 Booster Pumps). No. 1 2.5.24 Ditto, but 12'' steel 45o (Discharge side of PS-6 Booster Pumps). No. 1 2.5.25 Supply and install ½x4” pressure gauge (0-10 bar) with all necessary fittings and accessories required as shown in the Drawings and described in the Specifications and as directed by the Engineer (Discharge lines of PS-7 Booster Pumps). No. 3 2.5.26 Supply and install ½x4” pressure gauge (0-10 bar) with all necessary fittings and accessories required as shown in the Drawings and described in the Specifications and as directed by the Engineer (Discharge lines of PS-6 Booster Pumps). No. 2 2.5.27 Supply and install pressure switch on the main Lump 3 13 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty header connected to PLC panel, the switch shall be adjustable (0-10 bars). (Discharge lines of PS-7 Booster Pumps). sum Supply and install pressure switch on the main header connected to PLC panel, the switch shall be adjustable (0-10 bars). (Discharge lines of PS-6 Booster Pumps). Lump sum 2 2.6 Booster Pumps Supply and install horizontal centrifugal booster pumps and motors, installed and tested complete including pump, drilled hole, pipe connections, fittings, all manufacturer's recommended spare parts, supports and protection of surfaces, subsurface installations, including concrete bases and all parts needed for proper installation and operating of the pump in its place, all according to Drawings, Specifications, catalogues of manufacturer and instructions of the Engineer. 2.6.1 Pump for Booster Station PS-6, model (FHF 125270/1320) as manufactured by LOWARA, or equivalent of discharge 320 m3/hr for each, total dynamic head 88 m, complete with the drive motor 100 KW rated power, speed of pump = 2950 rpm. No. 2 2.6.2 Pump for Booster Station PS-7, model (FHS 100200/370) as manufactured by LOWARA, or equivalent of discharge 280 m3/hr for each pump, total dynamic head 38 m, complete with the drive motor 36 KW rated power, speed of pump = 2950 rpm. No. 3 2.7 Flow Meter Set Supply and install flow meter set complete including but not limited to the following: flow meter, steel piping and pipe connections, gate valve, fittings, reducers, coupling, flanges, bolts, gaskets, jacking and concrete supports, complete all as described in the Specifications and as shown on the Drawings and as directed by the Engineer. 2.7.1 Flow meter, 10'' – PN 16 bar ABB type or equivalent with possibility for remote data transferdata loggering including cable, ductbanks and connections (Discharge side of PS-7 Booster Station). Lump sum 1 14 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. Description Unit Qty 2.7.2 Flow meter, 8'' – PN 16 bar ABB type or equivalent with possibility for remote data transfer-data loggering including cable, ductbanks and connections (Discharge side of PS-6 Booster Station). Lump sum 1 2.8 Fire Hydrant Supply and install Fire hydrant 80mm diameter including stand post with flanged ends 4”/3”. The price shall include buried gate valve 4” with flanged couplings and box chamber and the provision and installation of 4”steel pipes (5/32” wall thickness, internally cement lined and externally polyethylene coated) with elbow, flanges and all necessary works including anchor blocks as shown in the drawings and directed by the engineer. Lump sum 1 2.9 Monorail hoist Supply and install electrical monorail hoist 1.5 ton capacity complete with "I" beam (300x150mmx42.2 kg/m), the base, the hook, the chain, the stopper, the fixing rods, painting and all necessary parts required for proper installation and operation, all as described in the Specifications and as shown on the Drawings and directed by the Engineer. Lump sum 1 2.10 Fuel Tank Supply and install cylindrical steel fuel tank with 4 m3 capacity and 6 mm thickness complete with all the required valves, fittings, fuel pump, float, pipe works, excavation, concrete foundation and backfilling all according to Drawings, Specifications and instructions of the Engineer. Lump sum 1 Lump 1 2.11 2.11.1 Pipe Connection (Provisional Items) Connection of the 12'' and 14 '' discharge pipes of PS-6 & PS-7 respectively to the adjacent trunk and distribution lines. The connection should include but not limited to the following: Supply and install dresser and necessary fittings complete but not limited to following: excavation and disposal of excess material to locations acceptable to the Engineer, bedding, all piping works such as welding, cutting and shaping, testing, bedding material surround the pipe, backfilling and compaction, and disinfection, complete all as directed by the Engineer. Before commencement, the contactor should adjust the alignment of pipes to be connected in order to reduce the use of elbows. Connection of the 12'' steel discharge pipe of PS-6, 15 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item No. 2.11.2 Description Unit to the adjacent 12'' new pipeline that connects the existing 10'' trunk line to ST-16, ST-17, ST-18A & 18B storage tanks. Connection of the 14'' steel discharge pipe of PS-7, to the adjacent 14'' new pipeline that Tal El-Sultan distribution network. sum Lump sum Qty Unit Price (US$) Total (US$) 1 Total Carried to Summary(Bill No. 2) BILL NO. 3 Electrical WORKS Item Description Unit Qty. Unit Price (US$) Total (US$) The items in general shall also include conduits, connection boxes, controls, wires, connectors, clamps, bolts, and connecting the cables to switchboards and common electric network are included in the unit price. Contractor shall submit shop drawings for all electrical works to be approved by the Engineer before executing the work. As-built drawings shall be submitted after handing over the work. All the electrical works shall be executed 16 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description according to Standards, specifications and supervisor instructions. Unit Qty. No. 1 Total (US$) drawings, engineer 3.1 3.1.1 Lightings Fittings Supply, install, connect and test fluorescent lighting fixture 2x36w complete with lighting tubes 36W, chock, condensers, starters, rigid PVC conduits, J. boxes, fixing screws (Galv.) and wiring. (Type is GA'ASH No. 50540 or equivalent). 3.1.2 Ditto, as (1) but with emergency back up power built in, for duration 3 hours. No. 1 3.1.3 Ditto, as (1) but water and dust proof IP65. (Type is GA'ASH No. 52940 or equivalent). No. 16 3.1.4 Ditto, as (3) but with emergency back up power built in, for duration 3 hours. No. 2 3.1.5 Supply, install, connect and test incandescent lighting fixture with 75W lamp, wires, conduits, j. boxes and fixing screws for ceiling mounted. (Type is GA'ASH No. 552100 or equivalent). No. 5 3.1.6 Supply, install, connect and test 6" Extractor fan with movable louvers, 250cfm, complete with PVC conduits, J. boxes, wiring, and all necessary accessories. (Type is VENTA or equivalent). No. 1 3.2 3.2.1 External Security lighting Supply, install external security lighting fixture with 150w bulb, HPS, chock, ignitor, condenser, 1.5" hot galvanized arm 2m,10A mcb, long 3X2.5sq. mm NYY cable and terminal blocks cables, (Type is GA'ASH No. 576003 or equivalent). No. 11 3.2.2 Supplying and erecting B200 concrete for pole base, including digging and lattice 4x1.25" bolts to fix the pole, the dimension of the concrete base is 80X80X100cm. No. 10 3.2.3 Supplying and erecting 8m long octal lighting pole, with 1cm thick base, the pole is made of 4-5mm thick hot galvanized sheet steel, including 20x12cm insulating fiberglass. No. 10 3.2.4 Supply, laying and termination of XLPE cable, (5X6) mm2 for external lighting including 3" pipe (flexible), 100cm digging and backfilling, and a warning tape the work. L.M. 140 3.3 Unit Price (US$) Switches and Sockets 17 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.3.1 Supply, install connect and test single pole one way switch, 220v, 13A, complete with PVC conduits, J. boxes, wiring, cover and all necessary accessories. (Type is GEWISS or equivalent). No. 1 3.3.2 Ditto, but water proof. No. 2 3.3.3 Ditto, but one way, two pole switch.(Type is GEWISS or equivalent). No. 3 3.3.4 Ditto, but water proof. No. 2 3.3.5 Supply, install connect and, testing single socket outlet 16A, 220v, 2p+E for flush or surface mounting, complete with PVC conduits, J. boxes, wiring, and all necessary accessories. (Type is GEWISS or equivalent). No. 10 3.3.6 Ditto, but water proof type. No. 8 3.3.7 Supply, install connect and, testing switched socket outlet 230V, 20A, with pilot lamp, flush type for water heater.(Type is GEWISS or equivalent). No. 1 3.3.8 Supply, install connect and, testing three phase socket outlet 3X16A, 380v, 3p+N+E, IP65 for flush or surface mounting, complete with PVC conduits, J. boxes, wiring, and all necessary accessories. (Type is GEWISS or equivalent). No. 2 3.3.9 Supplying and erecting telephone socket outlet, flush type, including 6 wire telephone cables. No. 1 3.4 Grounding system Supply, install and commission complete grounding system including all required galvanized 35x3 mm steel sheet, cables, earthing pits according to drawings, specification and engineers instructions. L.S. 1 No. 1 No. 7 3.5 3.5.1 3.5.2 Fire Alarm System Supply, install and commissioning fire alarm system as per drawings including fire resist PVC pipes, pull boxes special wires including : Fire alarm control panel 4 zones complete with batteries and all necessary accessories.(Type is TELEFIRE or equivalent). Lionization smoke detector, the detectors shall be twinchamber with latching electronic circuitry, two wire connection.(Type is TELEFIRE or equivalent). 18 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.5.3 Ditto, but heat detector. No. 1 3.5.4 Supply, install break glass cal point as per drawings the unit shall be standard type for interior use with key operated test facility, with plastic coated glass. No. 4 3.5.5 Supply, install 95 db electronic horn ultra sound for indoor and outdoor used. (Type is TELEFIRE or equivalent). No. 2 3.6 Main Distribution Board (MDB) Supply, install and commission main distribution panel board (MDB) as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm Galv. steel frame with anti static paint including busbars, neutral bus bar and earthing terminal and all necessary civil works for foundations , cable trenches and handing over clean, tested and in operating conditions. (Type is MOELLER or equivalent). Set 1 3.6.1 Over-load, current limiting switch, with over load and short circuit releases, adjustable 4-6A. (Type is MOELLER PKZM0-6 or equivalent). No. 4 3.6.2 Signal lamps R.S.T with 25 Resistance 220V. Set 3 3.6.3 3.6.4 3.6.5 Current transformer 3x (630/5A). Kwh meter 3 phases 3x5A. KVAR meter, 3 phases 3x5A. Set No. No. 7 1 1 3.6.6 Kwh meter, 1 phase 1x5A. No. 3 3.6.7 Ammeter 0-1000A. No. 9 3.6.8 Frequency meter (47-53Hz). No. 3 3.6.9 Voltmeter 0-500V with 7 positions selector switch. Set 3 3.6.10 Molded case circuit breaker with (over load protection) MCCB 4x630FA/4X630TA. (Type is MOELLER NZMH4-4-AE630 or equivalent). No. 2 3.6.11 MCCB 3x400FA/3X250TA. (Type is MOELLER NZMN3-AE400 or equivalent). No. 1 3.6.12 MCCB3x160FA/3X160TA. (Type NZMN2-A160 or equivalent). MOELLER No. 1 3.6.13 MCCB 3x100FA/3X100TA. (Type is MOELLER NZMN1-A100 or equivalent). No. 2 is 19 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.6.14 MCCB 3x40FA/3X40TA. (Type NZMN1-A40 or equivalent). is MOELLER No. 3 3.6.15 MCCB 3x25FA/3X25TA. (Type NZMN1-A25 or equivalent). is MOELLER No. 1 3.6.16 Ditto but MCB 3X40A. (Type is MOELLER FAZC40/3 or equivalent). No. 2 3.6.17 Ditto but MCB 3X32A. (Type is MOELLER FAZC32/3 or equivalent). No. 2 3.6.18 Ditto but MCB 3X25A. (Type is MOELLER FAZC25/3 or equivalent). Ditto but MCB 3X20A. (Type is MOELLER FAZC20/3 or equivalent). No. 1 No. 2 3.6.20 Panel ventilation system including, four extract fans, thermistor relay, temperature sensors (30-70 OC), 16A contactor, mcb 1X10A. Set 1 3.6.21 3 poles, 380V, 40kVAr, with 2 auxiliary contacts,220V coil, AC3 category (Type is MOELLER DIL2MKV-00 or equivalent). No. 2 3.6.22 3 poles, 380V, 20kVAr, with 2 auxiliary contacts, 220V coil, AC3 category (Type is MOELLER DIL1MK-10 or equivalent). No. 3 3.6.23 No. 1 3.6.24 3 poles, 380V, 10kVAr, with 2 auxiliary contacts, 220V coil, AC3 category (Type is MOELLER DIL00MK-02 or equivalent). Three phase static capacitor bank 30Kvar. No. 2 3.6.25 Three phase static capacitor bank 15Kvar. No. 3 3.6.26 Three phase static capacitor bank 10Kvar. No. 1 3.6.27 Toggle switch 10A, 230VAC (1, 0, 2) with indication lamp. Set 6 3.6.28 Supply and install surge protection at the incoming feeder 3- phase including connection to the ground. The system shall protect the switch panel against the lightning shocks. (Type Furse or equivalent). No. 1 3.6.29 LTL fuse 3x160A/100A. No. 1 3.6.30 Three-phase mains/generator automatic change over switch, motorized type, made of two 630A 400V 4poles switches with electrical and mechanical interlock K.Moller or equivalent ,the work includes automatic changeover unit (ACU) ADMAR type or No. 1 3.6.19 20 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.6.31 Ditto but manual change over switch 4x630A K.Moller or equivalent. No. 1 3.7 3.7.1 Motor Control Center (MCC) Supply, install and commission MCC panel board as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm Galv. steel frame with anti static paint including burbars, neutral bus bar and earthing terminal and all necessary civil works for foundations, cable trenches and handing over clean, tested and in operating conditions. (Type is MOELLER or equivalent). Set 1 3.7.2 Current transformer 3x (400/5A). Set 4 3.7.3 Ammeter 0-400A. No. 2 3.7.4 Ammeter 0-100A. No. 3 3.7.5 Electrical digital hour counter 3.5 digits, supply voltage 24V dc and/or 230V ac, panel mounting. No. 5 3.7.6 3.7.7 3.7.8 Toggle switch 10A, 24V dc and/or 230V ac, (1,0,2). Emergency push button switch. MCCB3x400FA/3X400TA. (Type is MOELLER NZMN3-AE400 or equivalent). No. No. No. 5 5 2 3.7.9 MCCB3x400FA/3X400TA. (Type NZMN1-A100 or equivalent). MOELLER No. 3 3.7.10 Three poles, 380V, 132KW, with 2 auxiliary contacts, 220V coil, AC3 category (By-pass). (Type is MOELLER DILM 250/22 or equivalent). No. 2 3.7.11 Three poles,380V, 43KW, with 2 auxiliary contacts,220V coil, AC3 category (By-pass). (Type is MOELLER DIL2M /22 or equivalent). No. 3 3.7.12 Three-phase solid state reduced voltage starter, 310A, for pump, fully featured, digital microprocessor based, with its control, as per specifications and engineer's instructions (Type is Solcon. RVS-D-310). Three-phase solid state reduced voltage starter, 105A, for pump, fully featured, digital microprocessor based, with its control, as per specifications and engineer's instructions (Type is Solcon. RVS-D-105). No. 2 No. 3 Motor protective circuit breaker 3X10A. (Type is MOELLER PKZM0-10 or equivalent). No. 5 Unit Price (US$) Total (US$) equivalent. 3.7.13 3.7.14 is 21 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.7.15 MCB 2X20A. (Type is MOELLER FAZ-C 20/2 or equivalent). Panel ventilation system including, three extract fans, thermistor relay, temperature sensors (30-70 OC), 16A contactor, mcb 1X10A. No. 1 Set 1 Set 1 3.7.16 3.8 3.8.1 PLC Cabinet Supply, install and commission PLC panel board as specified and as shown on drawings, factory assembled wired and tested in accordance with international standards, including 2mm Galv. steel frame with anti static paint including burbars, , terminal blocks and all necessary civil works for foundations , cable trenches and handing over clean, tested and in operating conditions. (Type is MOELLER or equivalent). 3.8.2 Programmable logic controller PLC, 128 I/O points, with hand programmer, computer software and interface, with sufficient updated RAM, and memory packs, logic memory. The unit shall be as per drawings, specifications, and engineer's instructions and the new version manufactured at the time of tendering. The work includes programming the PLC to operate the pumping station with 4 pumps(3-duty/1-standby), as specified by the engineer and according to the sequence to operate the pumps equal times, including all necessary extra relays and/or switches, cables and conductors, according to specifications and engineer's instructions. Phase failure, loss of phase, under voltage, and phase sequence relay, with the necessary control. L.S. 1 No. 1 3.8.4 Time delay electronic relay, with one N.O. and one N.C. 10A output contacts, and 2 sensor input points, supply voltage 24V dc and/or 230V ac, according to specifications and engineer's instructions. No. 7 3.8.5 Control relay, with N.O. and N.C. 10A output contacts, supply voltage 24V dc and/or 230V ac, according to specifications and engineer's instructions. No. 25 3.8.6 Push button switch with N.C. and N.O. contacts 10A, 24V and/or 230V AC. set 5 3.8.7 Supplying and erecting uninterruptible power supply U.P.S. 1000W rating, 50-60 minutes full load discharging time, 230V sine wave output, with all protection and indicators, as per specifications, and engineer's instructions. No. 1 3.8.8 Isolating transformer 380/220V of 2000VA capacity. No. 1 3.8.9 Ditto but 220/24V of 700VA capacity. No. 1 3.8.3 22 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.8.10 Manual change over switch 2X16A. No. 1 3.8.11 Indication lamps with 25 Resistance 220V. set 35 3.8.12 Over-load, current limiting switch, with over load and short circuit releases, adjustable 4-6A. (Type is MOELLER PKZM0-6 or equivalent). set 1 3.8.13 MCB 2X20A. (Type is MOELLER FAZ-C 20/2 or equivalent). No. 1 3.8.14 MCB 2X16A. (Type is MOELLER FAZ-C 16/2 or equivalent). No. 1 3.8.15 MCB 2X10A. (Type is MOELLER FAZ-C 10/2 or equivalent). No. 1 3.8.16 MCB 2X6A. (Type is MOELLER FAZ-C 6/2 or equivalent). No. 1 3.8.17 Ditto but MCB 1X6A. (Type is MOELLER FAZ-C 6/1 or equivalent). No. 4 3.8.18 Humidity sensitive relay, with N.O. and N.C. 10A output contacts, supply voltage 24V dc and/or 230V ac, according to specifications and engineer's instructions. No. 5 3.8.19 Temperature control relay, with N.O. and N.C. 10A output contacts, supply voltage 24V dc and/or 230V ac, according to specifications and engineer's instructions. (Type is MOELLER EMT6 or equivalent ) No. 5 3.9 3.9.1 Sub-Distribution Boards (DB-P) Supply, install sub-distribution board consists of lockable board frames as per specifications including 2m Galv. steel sheets with anti-static paint, bus bars for incoming cables, neutral and earthing terminal with all necessary accessories and material to hand over clean and tested ad in operating conditions. (Type is MOELLER or equivalent). No. 1 3.9.2 Miniature Circuit Breaker MCB 3X50A. (Type is MOELLER FAZ-B 50/3 or equivalent). No. 1 3.9.3 Miniature Circuit Breaker MCB 3X25A. (Type is MOELLER FAZ-B 25/3 or equivalent). No. 6 3.9.4 Ditto but MCB 1X16A. (Type is MOELLER FAZ-B 16/1 or equivalent). No. 3 3.9.5 Ditto but MCB 1X10A. (Type is MOELLER FAZ-B No. 4 23 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.9.6 Ditto but residual current circuit breaker 4X40/0.03A. (Type is MOELLER FI-40/4/003-A or equivalent). No. 1 3.9.7 Ditto but residual current circuit breaker 4X25/0.03A. (Type is MOELLER FI-25/4/003-A or equivalent). Sub-Distribution Boards (DB-S) Supply, install sub-distribution board consists of lockable board frames as per specifications including 2m Galv. steel sheets with anti-static paint, bus bars for incoming cables, neutral and earthing terminal with all necessary accessories and material to hand over clean and tested ad in operating conditions. (Type is MOELLER or equivalent). No. 1 No. 1 Miniature Circuit Breaker MCB 3X50A. (Type is MOELLER FAZ-B 50/3 or equivalent). Miniature Circuit Breaker MCB 3X40A. (Type is MOELLER FAZ-B 40/3 or equivalent). No. 1 No. 1 3.10.4 Miniature Circuit Breaker MCB 3X16A. (Type is MOELLER FAZ-B 16/3 or equivalent). No. 1 3.10.5 Ditto but MCB 1X16A. (Type is MOELLER FAZ-B 16/1 or equivalent). No. 6 3.10.6 Ditto but MCB 1X10A. (Type is MOELLER FAZ-B 10/1 or equivalent). No. 5 3.10.7 Ditto but residual current circuit breaker 4X40/0.03A. (Type is MOELLER FI-40/4/003-A or equivalent). No. 1 3.10.8 Ditto but residual current circuit breaker 4X25/0.03A. (Type is MOELLER FI-25/4/003-A or equivalent). No. 1 3.10.9 External lighting control unit including contractor(DIL 1AM ), selector switch 10A, photocell (KAJA type), 24 hours timer, 1X6A MCB. Set 1 3.11 3.11.1 Sub-Distribution Boards (DB-P) Supply, install sub-distribution board consists of lockable board frames as per specifications including 2m Galv. steel sheets with anti-static paint, bus bars for incoming cables, neutral and earthing terminal with all necessary accessories and material to hand over clean and tested ad in operating conditions. (Type is MOELLER or equivalent). No. 1 3.11.2 Miniature Circuit Breaker MCB 3X40A. (Type is MOELLER FAZ-B 40/3 or equivalent). No. 1 3.11.3 Miniature Circuit Breaker MCB 3X16A. (Type is No. 2 Unit Price (US$) Total (US$) 10/1 or equivalent). 7.10 3.10.1 3.10.2 3.10.3 24 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.11.4 MOELLER FAZ-B 16/3 or equivalent). Ditto but MCB 1X16A. (Type is MOELLER FAZ-B 16/1 or equivalent). No. 2 3.11.5 Ditto but MCB 1X10A. (Type is MOELLER FAZ-B 10/1 or equivalent). No. 2 3.11.6 Ditto but residual current circuit breaker 4X25/0.03A. (Type is MOELLER FI-25/4/003-A or equivalent). Cables and conduits Supply, laying under ground PVC piping system for the under ground electrical network as per drawings. The work includes manholes, excavation, laying pipes, warning tapes , backfilling ,new junction manhole and all required cable joints and cable extensions for the existing building cables. Supply, laying and termination of XLPE cable, (3X240+120) mm2. No. 1 L.S 1 L.M 230 3.12 3.12.1 3.12.2 3.12.3 Ditto, but NYY 1X185 mm2. L.M 125 3.12.4 Ditto, but XLPE 3X25+16 mm2. L.M 120 3.12.5 Ditto, but XLPE 5X10 mm2. L.M 50 3.12.6 3.12.7 Ditto, but XLPE 5X6 mm2. Ditto, but XLPE 5X4 mm2. L.M L.M 90 10 3.12.8 Ditto, but control cable 12X2.5 mm2. L.M 100 3.12.9 Ditto, but control cable 4X2.5 mm2. L.M 110 3.13 3.13.1 Miscellaneous Supplying and erecting complete lightning protection system including air terminal, copper conductors , pvc chairs, inspection boxes, earthing pit according to specifications, drawings and engineer's instructions.(Type is PuLSAR 45 or equivalent). L.S. 1 3.13.2 Supplying and erecting micro-switches connected to NVRs on the check valves. No. 5 3.13.3 Supplying and erecting electrical bell with flashing rotary lamp , 24V dc and or 220V ac, IP55 category, for out side use (external). No. 2 3.13.4 Supplying and erecting local isolated On/Off switch 3X400A rating lockable type for maintenance purpose to be installed close to the wet well inside weather proof enclosure (60X80X25cm). Type K. Moller or equivalent. No. 2 25 Unit Price (US$) Total (US$) ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. 3.13.5 Ditto but 3X100A. No. 3 3.13.6 Supply and install pressure switch on the main header connected to PLC panel, the switch shall be adjustable (0-10 bars). No. 3 3.13.7 Supplying and erecting electrical float switch inside the sewage and the storm water wet wells, IP 65 category, with N.O. and N.C. 10A contacts points, supply voltage 24V and/or 230V ac, according to specifications and engineer's instructions. No. 3 3.13.8 Supplying and erecting cables tray, MTK type or equivalent, 50cm width, with all fittings and accessories. No. 15 3.13.9 Ditto but lader type cables tray 50cm width. No. 25 3.13.10 Ditto but 30cm width. No. 10 3.13.11 Ditto but 20cm width. No. 10 3.13.12 Ditto but 10cm width. No. 10 3.13.13 Supplying and erecting IP54 category connection boxes, with the needed metal and/or PVC 2" pipes and accessories for cables connections. The boxes shall contain the control and power connection separately outdoor use. No. 2 L.S 1 L.S 1 3.14 Total (US$) Generator Set Supplying and erecting electrical generator and connect it to the storage fuel tank, the item shall include automatic start and stop, exhaust system, fuel pump and control, with automatic float, control, protection and control panel, sensors for heat, speed, under voltage, over voltage, oil pressure, phase sequence and phase failure, measuring instruments, air duct, built in fuel tank, alternator, diesel engine, exciter, automatic charger, main circuit breaker, sound attenuated enclosure (original) as recommended by the manufacturer. All fittings and fixing materials and control needed are included in the price. The generator shall be rated 400kVA standby rating. The price shall include also the supply and install of the generator steel shed, concrete pad and foundation, excavation for foundation and all works associated as shown in the Drawings and described in the Specifications and as directed by the Engineer. 3.15 Unit Price (US$) Transformer Substation Supply, install and test sub-station with all equipments, the work should be executed according to GEDCO 26 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah Item Description Unit Qty. Unit Price (US$) Total (US$) applications. The contractor must take into consideration all the coast required by GEDCO and other authorities for implementing this item. He must know that GEDCO will implement this work as a subcontractor under his responsibility applying all conditions on his regarding. The work includes all required steel arms and prackets,22 KV Pin & Tension Type Insulator, Wires & Clamps, Steel Bolts, UGC Components, 24 KV Switch gear SF6 (CTC), including 3 (22 KV) potsalan Fuses 60 A., Indoor Distribution Transformer 400 KVA and all other Accessories Total Carried to Summary (Bill No. 3) 27 ختم وتوقيع املقاول Construction of Water Booster Pumping Stations at Tal El-Sultan Water Storage Tank in Rafah CONSTRUCTION OF TAL EL-SULTAN BOOSTER STATIONS Summary: Item Description 1. Total of Bill # 1 2. Total of Bill #2 3. Total of Bill #3 Total (US$) Total (US$) Vat (0%) Grand Total (US$) Grand Total (in letters):------------------------------------------------------------Contractor’s Name:-----------------------------------------------------------------Signature and Stamp:---------------------------------------------------------------Date:------------------------------------------------------------------------------------- 28 ختم وتوقيع املقاول