Touch-Screen Graphical LCD Display Panel

advertisement
MODULERA
Modular UPS Systems
60 / 100 / 200kVA
3Phase in / 3Phase out
Main Features
 Hot Swappable Modularized Parallel Architecture
Decentralized parallel structure
 DSP ( Digital Signal Processor ) Controlled Technology
 Modular N+X Parallel Redundancy
 Parallel Operation up to 10 Power Modules
 High Power Capacity up to 200kVA on per single Rack
 Invest as You Grow , Easy to Upgrade
Common Battery Operation
Cold Start Function
Parallel connection availability of UPS Frames up to 4pcs
Main Features
Low Input Current Distortion (THDi <3% )
10.0
9.0
8.0
THDI(%)
7.0
6.0
R
5.0
S
T
4.0
3.0
2.0
1.0
0.0
25%
50%
75%
LOAD(%)
100%
Main Features
High Input Power Factor ( p.f. = 0.99 )
1.000
0.995
0.990
PF
R
S
T
0.985
0.980
0.975
25%
50%
75%
LOAD(%)
100%
Main Features
High Efficiency ( up to 94% )
Efficiency η
96.0
95.0
Efficiencyη(%)
94.0
93.0
η
92.0
91.0
90.0
89.0
25%
50%
75%
LOAD(%)
100%
Main Features
 High Output Power Factor ( p.f.= 0.9)
 Wide input voltage 208V~478Vac
Wide input frequency range ( 40Hz – 70Hz )
Plug & Play Type Hot Swappable Power Modules
 Each Power module with individual LCD display
 Touch-screen Graphical LCD Display Panel
 Centralized module monitoring is also available
Smart Fan Speed Control
Fan spins according to load percentage ;
50%: Spin slowly / over 50%: Spin at full Speed
Main Features
High MTBF ( 250.000 hours ) and Low MTTR
Battery Temperature Compensation
Powerful Charger Built in Module ( Max. 6Amp )
Equip with Maintenance Bypass Switch for easy maintenance
RS232 & 485 Ports as standard communication
Remote EPO Function
Megatec/Mod Bus Protocol
 Optional Communication Interfaces (SNMP or DRY contact)
MODULERA FRAME TYPES
 MDL 3300-60K
MDL 3300-100K
60kVA & 100kVA
 MDL 3300-200K
200kVA
MODULERA FRAME TYPES
 MDL 3300-60K = 3+1 Modules ( 3modules for power upgrade + 1module
for redundancy
 MDL 3300-100K = 5Modules
 MDL 3300-200K = 10Modules
Max. 4Frames can be connected in parallel
MODULERA POWER MODULE
MDL3320-RM 3/3 Power Module
20KVA/18KW Module
Compact Size
Only 3U Height
3U Only
Plug-and-Play Hot Swappable Module
 Safe Swappable Modular Concept
 Reduce SPOF(Single Points of Failure)
 Power Availability Increase
 High Power Capacity
 Reduced Footprint
 Flexibility/Scalability
 Less Service Cost
 Lowest Installation Cost
Battery Temperature Compensation
 Set from LCD Display
 Compensate from 20 C: Reduce
0.001V*6 of floating voltage per 1°C.
 0.002~0.006V * 6 per 1°C settable
Battery Voltage Configurable
 384/408/432/456/480Vdc Configurable
 Decrease Initial Investment
 Increase Competition
Derating Operation
Derating as per Temperature :
 Normal operation Temperature 0~40 C
 Max. operation Temperature 50 C
 De-rating operation: 10% per 5 C
Derating as per Altitude :
 Max. Altitude for normal operation : 1500m
The load capacity should be reduced as shown in the below table when
the UPS is installed in a place where altitude is higher than 1500 m;
Altitude
(m)
Load
coefficient
1500
2000
2500
3000
3500
4000
4500
5000
100%
95%
90%
85%
80%
75%
70%
65%
Powerful Charger
Each Power Module: 6Amp
60K: Max. 18A
100K: Max. 30A
200K: Max. 60A
Charging Current adjustable from LCD
3-Stage Intelligent Charging Modes
 Constant Current
 Constant Voltage
 Floating
(Boost Charge 2.30V to 2.35V per cell &
Float Charge 2.20V to 2.29V per cell)
Power Module LCD Display
 Input Voltage/Frequency
 Output Voltage/Frequency
 Load Capacity, Battery Voltage/Current
 Charge Modes/Charger Status
 Internal/Ambient Temperature
 Module ID/Status
 Alarm Codes
Touch-Screen Graphical LCD Display Panel
Touch-Screen Graphical LCD Display Panel
 Complete status information
about ;
ONLINE
30KVA
ID:01
◄
Input / Output / Battery /Modules
◄
Output
22-12-2008
08:30
Module
Phase Voltage(v)
Phase Current(A)
Frequency(HZ)
Active Power(kw)
Apparent Power(KVA)
Load percent(%)
Load crest factor
Input
A
220
1
50
0.0
0.0
0
0.0
Batt
Output
Module
Mains
Phase Voltage(V)
Phase Current(A)
Frequency(HZ)
Power Factor
Bypass
Phase Voltage(V)
Frequency(HZ)
ONLINE
30KVA
ID:01
22-12-2008
08:30
Input
Batt
A
380
220
50
0.97
220
50
►
State
B
C
380
380
220
220
0.97
0.97
220
220
►
State
ONLINE
30KVA
ID:01
◄
ONLINE
30KVA
ID:01
◄
Output
22-12-2008
08:30
Module
Module01
Invert Voltage(V)
Invert Current(A)
Frequency(HZ)
Positive Bus Voltage(V)
Negative Bus Voltage(V)
Code
8000-8000
0000-0000
Input
A
380
220
Batt
►
State
B
C
380
380
220
220
50
400
400
D800-8000
0000-0000
Back
Output
22-12-2008
08:30
Module
Input
Positive Battery Voltage (V)
Negative Battery Voltage (V)
Positive Battery Current (A)
Negative Battery Current (A)
Battery State
Battery Temperature (℃)
Lasting(min)
Batt
State
240.0
240.0
10.0
10.0
Charge
28
90
►
Touch-Screen Graphical LCD Display Panel
UPS Management Commands;
ONLINE
30KVA
ID:01
◄
22-12-2008
08:30
Command
Battery Test
Buzzer Set
Default Set
Setting
Record
Version
Battery Test
►
Buzzer Set
Mute
ONLINE
30KVA
ID:01
◄
Default Set
22-12-2008
08:30
Command
Language
Change Password
Date Setting
Back-light Delay
Contrast
Self-Test Date
Setting
Record
Self-Test Date
Mode: Weekly
Week: SAT
Time: 18:36
Lasting: 60min
Version
►
▲
ONLINE
▼
Back
Ensure Cancel
Next
30KVA
ID:01
◄
Command
22-12-2008
08:30
Setting
Record
Version
►
Work Mode
Single
LBS Group Setting
Ma
System Voltage Level
220
LBS Group Setting
System Frequence Level
50
Auto Turn-on
En
▼Master▲
Bypass Frequence Range
2
Ensure Cancel
Bypass Volt. Upper Limit
1
Back
Bypass Volt. Lower Limit
-30
Output crest factor
0%
Next
Touch-Screen Graphical LCD Display Panel
Settings;
ONLINE
30KVA
ID:01
◄
22-12-2008
08:30
Command
Setting
Language
Change Password
Date Setting
Back-Light Delay
Contrast
Self-Test Date
Record
Version
◄
ONLINE
30KVA
2008
ID:01
08:30
◄
Command
 System Parameters
2008-12-22 08:30:00
10Min
20
STA 18:36
FOR:60min
Back
ON:MON 08:48
OFF:SUN 17:25
Next
30KVA
ID:01
Timing of ON/OFF
 Language
►
 Working Modes
ONLINE
22-12-2008
08:30
Command
Setting
Work Mode
LBS Group Setting
System Voltage Level
System Frequency Level
Auto Turn-on
Bypass Frequency Range
Bypass Volt. Upper Limit
Bypass Volt. Lower Limit
O/P Volt
Micro tuning
22-12-
Record
Version
Single
Master
220V
50HZ
Enable
2%
10%
Back
-30%
0%
Next
►
Parallel ID
 Battery Voltage/Capacity
ONLINE
30KVA
ID:01
◄
Setting
Single Battery Volt.
Battery Number
Battery Group
Single Battery Capa.
Boost Upper Limit Volt.
Float Base Volt.
Battery Protect Volt.
Boost Charge
Boost Last Time
Max Charge Current
Record
12V
20
1
100AH
2.31
2.25
1.70
Enable
231 Min
25A
Version
Back
Next
►
22-12-2008
08:30
Command
Parallel ID
M/S hot standby Cyc.
UPS Output
Pre-Alarm Time
Float Volt Revise
Parallel Amount
Parallel Redundancy
Setting
Record
►
Version
01
6 Mon
Enable
14 Min
0.001
04
01
Back
Next
Touch-Screen Graphical LCD Display Panel
Record All
Events/Alarm Message;
ONLINE
30KVA
ID:01
◄
0001
0002
0003
0004
0005
0006
22-12-2008
08:30
Command
12-21
12-21
12-21
12-21
12-21
12-21
15:00:26
15:00:25
15:00:10
15:00:08
15:00:05
15:00:00
Setting
Record
►
Version
Display Up to 49
events
On Line
Rectifier Active..
Int.Input Switc..
Int.Bypass Swit..
Int.Output Swit..
Ext. Output Swit..
50 alarm messages
Back
Next
ONLINE
30KVA
2008
22-12-
ID:01
08:30
◄
Command
Setting
Record
ID:00 Record:0001
2008-12-21 15:00:25
Status:On Line
Event: On Line
Alarm:
CODE: CC00-0000 DF00-0000 0000
0000-0000 0000-0000 Quit
►
Version
▲
▼
Touch-Screen Graphical LCD Display Panel
Charge Current Setting :
ONLINE
30KVA
ID:01
◄
22-12-2008
08:30
Command
Single Battery Volt.
Battery Number
Battery Group
Single Battery Capa.
Boost Upper Limit Volt.
Float Base Volt.
Battery Protect Volt.
Boost Charge
Boost Last Time
Max Charge Current
Setting
12V
20
1
100AH
2.31
2.25
1.70
Enable
231 Min
25A
Record
Back
Next
Version
Max Charge Current
▼ 25 ▲
Ensure Cancel
►
Touch-Screen Graphical LCD Display Panel
Battery Qty & Capacity Setting :
ONLINE
30KVA
22-12-2008
ID:01
◄
08:30
Battery
Number Record
Setting
Command
Single Battery Volt.
▼ 20
Battery Number
Battery Group
Ensure
Single Battery Capa.
Boost Upper Limit Volt.
Float Base Volt.
Battery Protect Volt.
Boost Charge
Boost Last Time
Max Charge Current
ONLINE
30KVA
ID:01
◄
Command
Setting
Record
30KVA
◄
9
4
5
6
1
2
3
.
0
08:30
Command
Setting
Record
Version
Single Battery Volt.
Battery Group 12V
Back
Battery Number
20
Battery Group
1
Next
▼ 1 ▲ 100AH
Single Battery Capa.
Boost Upper Limit Volt.
Ensure Cancel 2.31
Float Base Volt.
2.25
Battery Protect Volt.
1.70
Boost Charge
Enable Back
22-12-2008Boost Last Time
231 Min
08:30Max Charge Current
25A
Next
Version
►
1000
8
22-12-2008
ID:01
Single Battery Capa.
7
►
ONLINE
▲ 12V
20
1
Cancel
100AH
2.31
2.25
1.70
Enable
231 Min
25A
Version
Can
cel
←
→
Ens
ure
►
Single Line Diagram
Multi-Communication Interfaces




2 x RS485 Ports
1 x RS232 Port
1 x Mod Bus Port
2 x Communication Slots
Communication Interface Options
 SNMP Card
Megatec Protocol Supported
Communication Interface Options
 Dry Contact Board
Pin
Function
1
Utility Failure
2
/
3
Battery Low
4
On bypass
O/P
5
UPS Fault
6
Inverter On
7
UPS Alarm
8
Common
9
+12V
I/P
10
0V
Fuses & Breakers
MDL 3300-60K
MDL3300-100K
MDL3300-200K
Input
Breaker ( present on
each power module as
built in )
3P 40Amp
230/400VAC
3P 40Amp
230/400VAC
3P 40Amp
230/400VAC
Output
Breaker ( present on
the frame )
3P 125Amp
380/400/415VAC
3P 250Amp
380/400/415VAC
3P 400Amp
380/400/415VAC
By-Pass
Breaker ( present on
the frame )
4P 125Amp
380/400/415VAC
4P 225Amp
380/400/415VAC
4P 400Amp
380/400/415VAC
Batteries
Breaker ( present on
the frame )
3P 175Amp
250VDC/415VAC
3P 250Amp
250VDC/415VAC
3P 600Amp
250VDC/415VAC
Mission critical & industrial applications
 Operator Centres, Servers, Computer rooms,
 Telecom Switchgear & Infrastructures,
 Processing Control Equipments,
 Security Systems, Emergency Lighting, Fire Protection,
 Airport Infrastructure,
 Bank, Hospital, Healthcare Equipment …
Download