Contact Name: Company Name: Address: Tel: Email: … ... … ... ... Uponor Reference: … Project Name/Address: Project Stage: Expected Order Date: … Please select. 00/00/0000 Underfloor Heating Requirements 1. Areas to benefit from Underfloor heating design: ... Floor type: Floor type: Floor type: Floor type: Please select. Please select. Please select. Please select. 2. Controls: ... 3. Heat source: ... 4. Notes: ... Areas: ... Areas: ... Areas: ... Areas: ... Please include plans with 1. Positions of heat sources and preferred manifold locations 2. Joist directions of timber floors 3. Joints and fire doors not to be crossed 4. Sensitive floors needing floor sensors and floor coverings if known. Please highlight any preferences for system, pipe and fittings. Unless specified we will allow for heating under kitchen units, baths, w.c. and showers. Please include heat loss information to help us optimise project designs. Reduce pipe wastage by using Uponor De-coilers and large pipe coils. Please email requests to projects.uk@uponor.com together with heat loss calculations and plans in DWG/ DXF or PDF format. RFQ-R1.3 RFQ-R1.3 Floor types Solid Screed floor – Kombi Clip fixings - Stapled clips hold Uponor pipe work securely to insulation. 16mm PEX, 20mm PEX and 16mm MLCP pipe options available. Complete flexibility for laying optimum pipe Patterns. Maximum output 100W/m2. Timber suspended floor – Heat Emission Plates - Aluminium trays fixed between the joists distribute heat evenly away from the UFH pipe work. 400mm Joist centre options with PEX 16 and MLCP 16 pipe. 300mm and 411mm centre options using PEX 20 pipe. CrossBattening can accommodate other joist spacings. - There should be no air gap between floors and trays, trays and insulation for efficient heat transfer. - A small gap should be left between plates to allow for their expansion. - Maximum output 70W/m2 - Solid floor – Self Attaching System - SAS offers a tool free fixing method that allows one individual to lay a heating system in half the time of traditional systems. - ‘Hook and loop’ technology for easy laying and repositioning of pipe simplifies the most complicated of heating layouts. - Integrated fixings across the pipe and insulation ensures a high retention force for robust installation. - Unique 16mm PEX system - Maximum output 100W/m2 Floating Floor - Can be laid over almost any existing floor surface. It is an ideal system for retrofitting UFH, or as an alternative to screeded floors. - 15mm/ 30mm and 50mm thick insulation options. - Additional insulation may be required on some ground floor installations to ensure compliance with Building Regulations. - Maximum output 70W/m2 RFQ-R1.3 Fixed Plywood Panels - A system with an ultra low profile of only 13mm, using grooved plywood panels bonded to aluminium heat plates. - Can be laid on almost any existing floor surface. It is an ideal system for retrofitting UFH, or as an alternative to screeded floors. - Additional insulation may be required on some ground floor installations to ensure compliance with Building Regulations. - Maximum output 70W/m2 RFQ-R1.3 Room Controls . Up to 12% additional energy saving 230V Multiple Digital Programmable Thermostats - - Each zone is programmable. Modern slim design offers only 13mm depth after installation. Features include holiday mode, temporary override, specific duration, 5/2 and 7 day settings, floor temperature control, lock facility and status displays. Energy saving feature calculates heat-up times of a system. Sensors are available for sensitive wooden floors. Low Voltage Multiple Digital Programmable Thermostats - Each zone is programmable. - - Features include Large LCD screens and simple menu navigation. Programmes for 5/2, 6/1, 7 day, Eco and Comfort settings. Patented ‘Auto-balancing’ technology of heat demands delivers up to 12% energy savings on other systems. Sensors are available for sensitive wooden floors. Up to 12% additional energy saving Low Voltage Central Timer with Dial, Public or Digital Thermostats - - - A central timer offers a large LCD screen and simple menu navigation. Programmes include 5/2, 6/1, 7 day, Eco and Comfort settings, with an additional facility for remote access via module 1046485. Any combination of Low Voltage Digital, Dial or Public thermostats can be used in combination with the timer. Each timer and controller can accommodate up to 12 thermostats and 14 heating loops. Multiples can be used to accommodate larger projects. Sensors are available for sensitive wooden floors. Radio Central Interface with Dial, Public and Digital Thermostats - - - - Offering optimum control and comfort, together with the easy installation and flexibility of wireless technology. Patented ‘Auto-balancing’ technology and dynamic energy management delivers up to 12% energy savings on other underfloor systems. Each Radio Interface can link up to 36 individual thermostat controls and 42 heating loops. Features include 5 temperature setback programmes, holiday mode, setting of room names, displays of all setpoint and actual room temperatures, comfort settings, and supply diagnosis. Remote access is available with an additional module 1046485. Any combination of Digital, Dial or Public thermostats can be Used with the central interface. Digital thermostats are available in black, silver and white. Sensors are available for sensitive wooden floors. RFQ-R1.3 Water Temperature Controls Control Pack HTG V5 - A compact, all-in-one solution for controlling Underfloor - heating flow rates and water temperature. “A” rated energy efficient Wilo 6m pumps for low running costs. Control Packs are available in sizes from 2-port to 8-port. Separate manifolds range from 2-port to 12-port. They are capable of supplying areas up to 150m2 at 100W/m2. Underfloor heating systems can be made up of multiple control packs, in central positions to supply heating loops efficiently. PPG-30 - Mixes variable water temperature to manifolds for heating and cooling. - External Weather Compensation Control intelligently balances the water temperatures based upon changing external climates and user demand. “A” rated energy efficient Wilo 8m pumps for low running costs of large areas. More than one manifold can be supplied by a single unit if the floor constructions are the same for installation savings. - - VPG-10 with Actuator/ PPG-20 - Mixes a fixed water temperature to manifolds. - “A” rated energy efficient Wilo 6m pumps for low running costs. - VP-10 rated for 15KW. - PPG-20 rated for 20KW and compatible with Climate Controller for intelligent variable mixing. - Can be installed directly to manifolds, at angles or separate to the manifolds, giving greater flexibility in awkward spaces. None – Water temperature controls supplied by others - For example when being served directly by a controlling heat pump. PPG-30 rated for 30KW The Radio Controller (room controls) and Climate Controller (water controls) are designed to work side by side. Installation wizard simplifies setup. RFQ-R1.3 Heat Source Please let us know what types of heat source will be used on your project. Heat source examples include boiler, solar, wood pellet, air-source heat pump and ground source heat pump. With heat pumps the water temperature control is supplied by others unless specifically requested. In these cases we recommend the Uniset controllers for lower temperature requirements. Please ensure the heat pump is rated to efficiently handle 40-45®C supply temperatures for screed and 50-55®C for timber floors with your project. Notes Please let us know of any project areas requiring special attention, key preferences or information that may help refine your Underfloor heating. RFQ-R1.3