The Muon Shifter

October 2009

1

Forewords

Introduction

This pages are meant to initiate people who are not familiar with ECS (Experiment Control System), and Muon

ECS in particular, to perform shifts in global data taking run. In this sense, information given here are very basic and in general refer to a non-expert use of the system: setting-up of the system for DAQ runs, first check of proper running conditions, first simple interventions in case of simple frequently encountered problems.

This basic manual can also be a starting point for a richer documentation while the operator skill increases and the control system becomes more stable and complete.

Please note also that the ECS system is still under development. Changes on the panels and even on the structure is still possible. This pages should not be meant as a user manual of a delivered project/system, but just to gain a first idea on system operation.

Muon ECS (basics of the) basics

The LHCb Experiment Control System (ECS) is based on the PVSS framework. You can find some documentation on PVSS and LHCb ECS at page http://lhcb-online.web.cern.ch/lhcb-online/ecs/default.htm

and in particular the tutorial http://lhcb-online.web.cern.ch/lhcb-online/ecs/powerpoint/LHCb_ECS_Tutorial.ppt

which we warmly suggest you to read.

The ECS is based on so-called PVSS projects running on dedicated online PCs. Each project runs on independent partitions. The MUON ECS has several project types, controlling:

• FEB (Front End Boards, i. e. CARDIAC via the Service Boards)

• ODE (Off Detector Electronics Boards)

• LV and HV

• Gas, Temperature, RAC power

• Tell1

• FSM (Finite State Machine & Hierarchy) projects

The last projects do not directly control any hardware but the hierarchical structure of the ECS itself. The FSM allows the ECS commands to circulate from top to bottom of the structure, thus making possible the communications among the complete system.

2

The Muon Detector DAQ and Control electronics chain

Front-end Boards (CARDIAC):

2 ASIC

-CARIOCA (ASD chip)

-DIALOG (logic, timing and monitoring)

DIALOG is configured and read back by SB (Service

Board).

Service Boards are placed in an off detector rack.

The same rack houses the

PDM board (Pulse

Distribution Module) : it generates pulses in a chosen phase with the LHC machine clock for the time alignment of the muon system.

The IB (Intermediate Board) make logical combinations of the front-end channels (logical channels) where the combination is not possible at DIALOG level

The ODE (Off Detector Electronic Board) receive signals from the FEBs (or IBs), synchronize and displace them to the L0 trigger. Upon reception of a trigger signal data are sent to the TELL1 board and from here to the DAQ (next slide for picture)

3

The Muon Detector DAQ and Control electronics chain (II)

L0 Muon Trigger processors

Muon TELL1

DAQ

ODIN

The ODIN board distributes all orbit signals (clock, trigger, L0 reset,…) to the ODEs, Muon

TELL1s and Trigger processors (to all boards that are synchronuos and have the TTCrx chip)

4

Muon detector back side view: each station M1-M5 is divided in four quadrant Q1-Q4

C side A side

M1

M3

M4

M2

M5

Q4 Q1 z

Q3 Q2

Interaction point

5

The Muon ECS

The structure of ECS consists of 3 types of objects: Device Unit (DU),

Control Unit (CU) and Logical Unit (LU).

 DU is an object controlling a hardware component (e.g. a CARDIAC board)

 CU is just a hierarchical object, passing commands and states on a hierarchical node

 LU is useful to group different DU together and is rarely used in our case

The hierarchical structure allows also including and excluding portions of the system.

Following the general LHCb structure, also the Muon hierarchy is organized in two independent and totally symmetrical parts, MUONA and MUONC, controlled by a higher node, MUON. The deeper the hierarchical level, the wider the understanding needed of system and hardware details. However, in “normal” conditions it should not be necessary to go further than the MUONA/C level.

EACH PVSS PROJECT RUNS ON AN ONLINE PC . On Control Room PCs you will find shortcuts to the online PCs where really the projects run

6

PVSS Tree for Muon Detector

An example for the C side

MUON

MUONA MUONC

The Green bubbles are Control Unit (CU) of the:

•PVSS project MUSIDES

•PC: mudaqa01w

MUONC_DAQ MUONC_DCS

MUON_DCS_LV

MUONC_HV

Inside this CU there is the hierarchy of the

Muon detector High Voltage

•PVSS project MUHVC01 (PNPI - R3 R4)

•PC: muhvc01

•PVSS project MUHVC02 (CAEN – R1 R2)

•PC: muhvc02

Inside this CU there is the hierarchy of the Muon detector electronics:

Chambers/ODE/Tell1

•PVSS project MUDAQC

•PC: muecsc01w

Inside this CU there is the hierarchy of the Muon detector Low Voltage

•PVSS project MUDCSLVC

•PC: mulvc01w

7

PVSS Tree of Muon Detector

An example for the C side

MUONC_DAQ

MUONC_DAQ_Q3 MUONC_DAQ_Q4 MUONC_DAQL1

MUONC_DAQ_Q3M45C MUONC_DAQ_Q3_M1C MUONC_DAQ_Q3_M23C

MUONC_DAQ_Q3_M23C_M2

MUONC_DAQ_Q3_M23C_M3

MUONC_DAQ_Q3_M23C_CRC

Inside this bubble there is the hierarchy of the DAQ tell1 boards witch take the data coming from the

ODEs:

•PVSS project MUDAQL1

•PC: mudaq01

Inside this bubble there is the

SB/PDM crate for station

M2&M3 Q3&Q4

•PVSS project MUDAQC23

•PC: mudaqc03w

8

PVSS Tree for Muon Detector

An example for the C side

MUONC_DAQ_Q3_M23C

MUONC_DAQ_Q3_M23C_M2

Q3_M3_R1

Q3_M3_R1_HU1

MUONC_DAQ_Q3_M23C_M3

Q3_M3_R2

MUONC_DAQ_Q3_M23C_CRC

Q3_M3_R3 Q3_M3_R4

Hardware Unit

Q3_M3_R1_HU2

HU: Hardware Unit is made by One ODE and all the

Chambers connected to it

Chambers ----------------------

•PVSS project MUDAQC23

•PC: mudaqc03w

ODE ---------------------------

•PVSS project MUODEC01

•PC: muodec01w

Chambers

9

Use

Feb 2&3/C

Feb 4&5/C

Feb 1/C

Feb 1/A

Feb 2&3/A

Feb 4&5/A

FSM/C

FSM/A

LV/C

LV/A

Comp name

MUDAQC03w

MUDAQC04w

MUDAQC01w

MUDAQA01w

MUDAQA03w

MUDAQA04w

MUECSC01W

MUECSA01W

MULVC01w

MULVA01w

PVSS Id

260

261

262

263

264

265

279

280

210

211

Project Name

MUDAQC23

MUDAQC45

MUDAQC1

MUDAQA1

MUDAQA23

MUDAQA45

MUDAQC

MUDAQA

MUDCSLVC

MUDCSLVA

HV/C

HV/C

HV/A

HV/A

MUHVC01

MUHVC02w

MUHVA01

MUHVA02w

212

213

214

215

MUHVC01

MUHVC02

MUHVA01

MUHVA02

ODEQ3/C

ODEQ4/C

ODEQ1/A

ODEQ2/A

T&P

MUODEC01w

MUODEC02w

MUODEA01w

MUODEA02w

MUDCS01w

266

267

268

269

270

MUODEC01

MUODEC02

MUODEA01

MUODEA02

MUDCSSEN

TELL1

M5 :

M4 :

M3 :

M2 :

M2:

M1:

M1: mudaq01 216 MUDAQL1 mutella01 (Q1/Q2) mutellc01 (Q4/Q3) mutella02 (Q1/Q2) mutellc02 (Q4/Q3) mutella03 (Q1/Q2) mutellc03 (Q4/Q3) mutella04 (Q1) mutellc04 (Q4) mutella05 (Q2) mutellc05 (Q3) mutella06 (Q1) mutellc06 (Q4) mutella07 (Q2) mutellc07 (Q4)

MUON TOP mudaqa01w MUSIDES

MUON on-line PCs and their use

Here a complete list of the online PCs and the relative projects running on them is given

Comments:

1.

2.

3.

Access to this machines to start/stop/operate the PVSS projects should normally not be needed but for experts.

As a general rule, PC names ending with W are Windows-based PCS,

Linux otherwise.

Some of the reference experts are:

D. Pinci for FEBs,

S. Cadeddu for FSM,

M. Lenzi for LV and HV,

M. Carletti for ODE,

G. Graziani for Tell1 and Muon

Monitor,

C. Deplano.

10

HV

HV

A SIDE

HV

ECS - PVSS world

19 PCs

20 PVSS projects

HV LV

LV

DCS

MUON

C SIDE

ODE

ODE

CMB

CMB

TELL1

CMB

CMB

ODE

ODE

11

5

Panels and States

ECS operation is based on control panels, giving information on system status and allowing intervention of the operator to trigger a status change. Although intuitive, it is important to give some explanations on the use of the panel buttons.

Sub-System buttons: clicking with the left mouse button opens the corresponding CU

{

Sub-System state, visualizing the current state. Clicking with the left mouse button gives the list of possible actions which can be done from it.

Lock button: the system can be accessed/controlled by different parts of

ECS. This button says who is presently

TAKING the system and its inclusion/exclusion in the hierarchy. This info can be gained by placing the mouse tip on the lock. Before operating on a given system/subsystem you need to TAKE it (if possible). During Global data taking “your” system must be controlled by the global manager and the muon operator must release it properly (see next pages).

Using the left mouse button it is possible to change the lock status.

Presently loaded recipe. A recipe is the collection of all the configuration parameters/variables needed for a specific data-taking run. Usually the shifter should not choose one recipe rather than another (it is already loaded).

If further information is needed on recipe handling, for the moment you have to refer to an expert.

MUONA CU Panel

NEVER use this button to dismiss the panel

ALWAYS USE the Close button

12

1. How to ...

Prepare the MUON system for global DAQ run when everything is ok .

In normal conditions, the PVSS projects (FEBs, ODE, FSM) are up and running. This condition should be reached automatically at each power-on of the machines where the projects are installed

(see list on next page). At the moment (June 08), this is implemented only for the LV control projects, but will be done soon also for the FEBs and the ODEs.

Being in this condition, the steps to set-up the system for DAQ are the following: i.

On any computer of the on-line cluster*, go to directory G:\online\ecs\Shortcuts38\MUON ii.

Launch (double click) the two shortcuts MUSIDES_UI_DEN and MUSIDES_UI_FSM . This visualizes the two control windows for DEN (Device Editor Navigator) and FSM (Finite State

Machine) Hierarchy (see next page).

Launching the shortcuts does not start the DEN and FSM processes (which are already running within the PVSS project), but just allows using the corresponding control windows from your screen.

(*you need an account within the on-line cluster: ask Niko Neufeld if you haven’t any.)

13

FSM panel

The FSM panel you should have opened allows visualizing the status of the full

MUON hierarchy and opening panels related to any hierarchical level.

Concerning the DU/CU status, the color code is as follows: grey for DEAD/NOT INCLUDED yellow for NOT READY orange for UNKNOWN/NOT ALLOCATED red for blue for green for

ERROR

READY or ACTIVE (TFC case)

RUNNING

Now, placing the cursor tip on the MUON box and clicking the RIGHT mouse button, opens the MUON CU, which represents the top level of our hierarchy, see next page(s).

This box accesses the TELL1 CU (refer to page 15)

14

MUON CU panel

In order to allow the global manager driving the MUON

System, the MUON must be

NOT_READY and its subsystems NOT_ALLOCATED.

All the locks should be grey and open, without any slash on them (which means Not

Included).

Although this condition appears to be verified in the shown panel, it is equally necessary to check the

MUONA and MUONC CU.

Checking deeper levels is not required to a shifter.

The first operation is TAKING the MUON System under your control. Click (LEFT mouse button) on the lock and select

TAKE. The lock goes green and closed.

A panel automatically pops up, giving the list of

LockedOut nodes and of CU which were not possible to take (more details on page

12).

Now OPEN (double click) the two sides (A & C)

15

MUONA CU panel

(The MUONC panel has similar face)

If everything is correct, the panel appears in the configuration shown.

In this conditions, you can release the MUON system in order to make it possible the control by the global console (go to next page)

16

MUON CU panel

In order to release the MUON system, click on the green lock and choose ReleaseAll in the pop-up menu (the Release button releases this level of

CU but not those below it).

The MUON status goes to

NOT_READY and the system is free to be used by the global console.

Note:

Case of a subsystem taken by someone else.

Placing the mouse on, you obtain info on owner and status. In Global DAQ, the global manager decides what is to be included/excluded.

You have to take care only of

MUON, putting it in regular shape.

17

2. How to ...

Prepare the MUON system for global DAQ run when something is not the right way .

iv.

v.

vi.

i.

ii.

iii.

Suppose that opening the MUONA panel, a different status is shown

(see figure):

Some subsystems appear to be locked out and the TFC is

ACTIVE, while the right status is

NOT_ALLOCATED for the TFC and NOT_READY for the others

{

In such a case, these are the steps to follow:

Release MUON (ReleaseAll)

TAKE MUONA (where the problem was found)

ACTIVE  Stop run 

READY

READY  RESET

NOT-READY 

DEALLOCATE

ReleaseAll (in the lock)

This should take again the

MUONA in the right shape

18

DEAD states

When you

TAKE a

System, an Action

Report appears.

In some cases a subsystem cannot be taken because its state is DEAD

(i.e. The FSM cannot communicate with it, or the FSM is blocked there)

DEN panel

The DEN panel (you got from page 7) is to be used in case of DEAD states : click on the Start/Restart All button for the relevant stage of the hierarchy

(use the FSM tab). This activate the FSM only on the relevant stage and should cure the DEAD state.

19

TELL1 CCPC restart (1)

When the the system is being reset or configured, it may happen that the system enter an ERROR state .

This state propagates from the DU/CU which originates it, up to the top level of the hierarchy (MUON in our case).

Frequently this is caused by the Tell1

CCard, needing to be restarted (see next page).

(see next slide also to know how to get to the

MUONA(C)_DAQL1 panel).

Here “ERROR” appears

20

TELL1 CCPC restart (2)

Here is how to (possibly) cure a

TELL1 ERROR state

1.

Descend the hierachy starting from the MUON CU panel: MUON  MUONA (e.g.)  MUONA_DAQ 

MUONA_DAQL1(see previous slide). Alternatively, you can access the Tell1 panel directly from the FSM

(see page 8).

2.

Spot the Tell1 which is in error and identify the corresponding CCPC (see subsystems in the panel and the given correspondance table).

3.

Log in on the CCPC using your user/pwd and start the ccserver (using putty, for example).

4.

Type the command “sudo service ccserv restart”. You should obtain a double ok. If not, try to repeat the command.

This restarts the ccserver and should solve the ERROR

Side A

PC TELL1 mutella01 MUTELLA_M5Q12 mutella02 MUTELLA_M4Q12 mutella03 MUTELLA_M3Q12 mutella04 MUTELLA_M2Q2 mutella05 MUTELLA_M2Q1 mutella06 MUTELLA_M1Q1

Mutella07 MUTELLA_M1Q2

Side C

PC TELL1 mutellc01 MUTELLC_M5Q34 mutellc02 MUTELLC_M4Q34 mutellc03 MUTELLC_M3Q34 mutellc04 MUTELLC_M2Q4 mutellc05 MUTELLC_M2Q3 mutellc06 MUTELLC_M1Q4 mutellc07 MUTELLC_M1Q3

21

Low Voltage panels (2)

Take before

And release all when finished

Q1 panel

22

Low Voltage panels

The LV domain is reachable from the MUON panel, from the

MUONA_DCS and MUONC_DCS hierarchy.

Click directly on the relevant CU (RIGHT mouse button), or start from the top level clicking on MUONA_DCS on the FSM panel. The corresponding panel appears.

From this panel you can descend the hierarchy across quadrants and stations reaching the LV controls (see next slides)

23

At this level, the different sub-systems of LV are visible and accessible

Q1M23A panel: DAQ tab

The DAQ tab refers to ODE, SB

& PDM, IB crates

Act only on the FSM buttons to switch on/off the sub-systems.

This part of the panel should be used only to check the effects of the action, not to cause them

24

The FEE tab refers to the

CARDIAC boards

Q1M23A panel: FEE tab

25

Starting the MuonMoni Presenter

The better way to check the global status of the detector is looking at the data quality by means of the online Presenter.

To start the Presenter:

1.

2.

3.

4.

5.

Launch Exceed on your PC. There is a small problem with the new Exceed: the default configuration settings are re-set by the installer.

Host access is now per default *DISABLED*. To change this open Exceed -> Tools ->

Configuration -> Security and remove the access control.

Log on mudaq01 (*) type: . /group/muon/scripts/lhcbsetup.sh

set local display: export DISPLAY=pcname:0.0 (**) run presenter:

/group/online/presenter/run_presenter.sh

(*) Log-in using putty:

- session: mudaq01

- connection

SSH

X11 (enable x11 forwarding) open and login

(**) PC name : see label glued on the monitor

See the twiki page https://twiki.cern.ch/twiki/bin/view/LHCb/MuonDaqMonitoring about the use of the Presenter

26

How open the PVSS panels for a linux PC

For example: tell1 PC

The PC is: mudaq01 (login with Putty)

Command line to open the “gedi” panel: PVSS00ui –proj MUDAQL1 –m gedi

On “gedi” go:

- Module

- Vision

- localdisk/PVSS/MUDAQL1/panel

- /grup/muon/fwComponent_MUDAQL1/panel

To open the “DEN” panel

- select the folder fwDeviceEditorNavigator

- open fwDeviceEditorNavigator.pnl

27

How create or upload a recipe for CMB

1.

Go into MUON_DAQ panel

2.

Create a new recipe

• Select the parameters needed

(Thresholds, Masks, …)

• Select the detector regions/side

• Push “set the configuration to region …”

• Check “re-load timing result” if the timing parameter have been changed

• write the recipe name

• Push “Create Recipe”

• Wait until the process-bar arrive at 100%

3.

Upload an existing recipe

• Select the detector region/side

• Push “set the configuration to region …”

• Select a recipe from the

“Recipe List”

• Push “upload Recipe”

• Wait until the process-bar arrive at 100%

28

How create recipe for ODE starting from timing test file

1.

2.

3.

1.

2.

3.

4.

5.

6.

Configure the ODE starting from the timing file

1.

2.

3.

Go into the HU you need from the Musides shortcut and reset the ODE board

Push “go to expert” and “continue”

Into the tab “commands” push “Load HW Conf File”

1.

Select the file you want write into the hardware

Save a PULSING recipe

Go into the corresponding ODE PC

Open the ODE panel you want to change from the DEN

Push “recipes…”

Select the recipe you want create or overwrite (for example PULSING )

Create the recipe “Create from hardware”

Select “PULSING” recipe and push “edit”

1.

2.

3.

4.

Check that all “GOLCTRL” value are 0x00

1.

If not: push “edit” into “table Mode”

Write 0x00 for all the column “GOLCTRL”

Push “enter” into the keyboard: the changes you made became yellow

Push “save” and “close”

2.

3.

4.

5.

Save a PHYSICS recipe

1.

Go into the corresponding ODE PC

Open the ODE panel you want to change from the DEN

6.

7.

Push “recipes…”

Select “PHYSICS” recipe and push “edit”

Take note of the value of the TTCrx registers “FD1” and “CD” and “close”

Create the recipe “Create from hardware”

Select “PHYSICS” recipe and push “edit”

1.

2.

3.

4.

push “edit” into “table Mode”

Wrote the value you have toke note for TTCrx “FD1” and “CD” registers

Push “enter” into the keyboard: the changes you made became yellow

Push “save” and “close”

29

In the Cavern:

Chambers/CARDIAC

SB/PDM IB ODE

HV distributor

LV Marathon

Muon Chambers

In B1:

LV distributor

(RCM/ACDC)

In D2:

PCs with PVSS projects and SYSTEC witch connect ECS signals from SB/PDM/ODE to the PC)

In D3:

Tell1 boards for

DAQ and L0 trigger

IB

ODE

SB/PDM