Introduction to tDS-700 Series tGW-700 Series Jan. 20, 2011 Vio Fan ICP DAS Co., Ltd. 1 Features Comparison PPDS PDS DS tDS tGW Virtual COM Yes Yes Yes Yes - Programmable Yes Yes - - - PoE Yes - - Yes Yes Modbus Gateway Yes - - - Yes Multi-client Yes Yes Yes - - Isolation for DS-715 Costeffective Costeffective Features\ Series Remarks 2 Specifications Comparison I-7188EN PDS-700 MiniOS7 MiniOS7 --- 80188-40 MHz 80186-80 MHz 32-bit MCU 50MHz Ethernet 10 Mbps 10/100 Mbps 10/100 Mbps EEPROM 2 KB 16 KB --- Frame Ground --- Yes Yes Total Models 8 10+ 7+ Models with DI/DO 2 5 0 Yes Yes --- Yes OS CPU Virtual COM Virtual I/O 3 tDS-700 tGW-700 Yes ----- tDS/tGW-700 Common Features Tiny Device Server tDS-700: Tiny Device Servers Tiny Modbus Gateway tGW-700: Tiny Modbus 4 tDS/tGW-700 Common Features Contains a 32-bit MCU that efficiently handles network traffic 10/100 Base-TX Ethernet, RJ-45 x1 (Auto-negotiating, auto MDI/MDIX, LED Indicators) Includes redundant power inputs: PoE and DC jack Supports TCP, UDP, HTTP, DHCP, BOOTP and TFTP protocols Supports UDP responder for device discovery Allows automatically RS-485 direction control Supports pair-connection applications Allows easy firmware updates via the Ethernet Contains a tiny Web server for configuration Tiny form-factor and low power consumption RoHS compliant and no Halogen Made from fire retardant materials (UL94-V0 Level) Redundant Power Inputs PoE (IEEE 802.3af, Class 1) ◆ DC Jack (+12 ~ 48 VDC ) Automatic MDI / MDI-X crossover tDS-700 / tGW-700 Naming Conventions tDS-7 X Y tGW-7 X Y X: Number of Total Ports Y: Serial Ports Type 2: 4: 5: 8: RS-232 RS-485 and RS-232 RS-422 / RS-485 RS-232 / 422 / 485 8 tDS-700 (tGW-700) Selection Guide COM 1 COM 2 COM 3 tDS-712 tGW-712 tDS-722 tGW-722 tDS-732 tGW-732 tDS-715 tGW-715 tDS-725 tGW-725 tDS-735 tGW-735 tDS-718 tGW-718 5-wire RS-232 5-wire RS-232 3-wire RS-232 2-wire RS-485 4-wire RS-422 2-wire RS-485 2-wire RS-485 3-wire RS-232 5-wire RS-232 3-wire RS-232 2-wire RS-485 4-wire RS-422 2-wire RS-485 3-wire RS-232 2-wire RS-485 2-wire RS-485 We are planning to have two new models as follows: tDS-724 (tGW-724) : RS-485 x1, RS-232 x1 (5-wire) tDS-734 (tGW-734) : RS-485 x1, RS-232 x2 (3-wire) 9 UDP Search Use "eSearch Utility“ or “VxComm Utility”, you can find the module quickly and configure the proper network settings. Init Switch If there are something wrong in network settings or other settings accidentally, you can make the switch is placed in the “Init mode”. After re-booting, all values can be restored to factory settings. Mode Flash Protection Firmware Update Configuration Initial No Yes Factory Run Yes No User-Defined Firmware Update (1/2) Connect the tGW-700 to the same HUB or same sub-network as your PC. (For tDS-700, tGW-700, PETL-7000 and tPET Series) Right-click above the module name and choose the firmware file in “eSearch Utility”. Power-on reboot the module in initial mode to request the update. 12 Firmware Update (2/2) The tGW-700 has a built-in feature of flash protection that prohibits modification to the firmware in the flash. Before updating the firmware, we have to set “Init Switch” in “Init” state and then power-on reboot the tGW-700 and disable the flash protection. Since the flash becomes writable, we can update the firmware through the Ethernet network 。 The code (in the boot loader) used to update the firmware image is not part of the firmware it-self. Thus, users can update the firmware even the built-in one is broken or does not exist. If the firmware update fails, we just need to rerun the update procedures again. tDS/tGW-700 Common Features Tiny Device Server tDS-700: Tiny Device Servers Tiny Modbus Gateway tGW-700: Tiny Modbus 14 tDS-700 Features Incorporates any RS-232/422/485 serial device in Ethernet Supports pair-connection (serial-bridge, serial-tunnel) applications Male DB-9 or terminal block connector for easy wiring Allows easy firmware updates via the Ethernet Contains a tiny Web server for configuration Cost-effective Device Servers 15 Virtual COM Basis Command/Data/Modbus/Anything Command/Data/Modbus/Anything Transparent (with no protocol convert) VCOM6/7 VCOM6/7 Transparent Meter RS-485 10/100 M Ethernet PLC RS-485 tDS-725 PLC Meter Note: 1. In the virtual COM application, the command or data is being copied between the PC and tDS-700 module with no protocol convert. This allows most of the serial protocols can be used with the virtual COM. Virtual COM Application VxComm Driver VCOM5 VCOM6 VCOM7 VCOM8 … 10/100 M Ethernet VCOM5 RS-232 RFID Reader tDS-712 VCOM6 RS-485 PLC Meter tDS-715 VCOM7 RS-485 NS-208PSE Ethernet Switch with PoE PLC VCOM8 tDS-725 RS-485 Note: 1. The max. COM port number in a PC is up to COM256. 2. The COM port is configured and mapped by using the VxComm Utility. Meter Direct TCP Socket Connection Send raw data via TCP socket. Raw data Transparent (with no protocol convert) 10/100 M Ethernet Port 10001 (COM1) Port 10002 (COM2) Meter RS-485 PLC RS-485 tDS-725 PLC Meter Note: 1. The serial ports of the tDS-700 can be also accessed via TCP socket connections. TCP port 10001 = COM1, TCP port 10002 = COM2, TCP port 10003 = COM3. 2. Users have to configure the baud rate and data format via web configuration first, else the serial ports may send garbage data. Serial Port Pair-connection Basis Virtual RS-485 bus through the pair-connection. Port 1(RS-485) Port 1(RS-485) PLC 1 uses 115200 bps Serial Port Pair-connection Through the Ethernet tDS-715 uses 115200 bps PLC 2 uses 115200 bps tDS-715 uses 115200 bps Note: 1. PLC 1 and PLC 2 can communicate with each other via the RS-485 port that has pair-connection link through the Ethernet. Pair-connection with Different Baud Rate Virtual RS-485 bus through the pair-connection. Port 1(RS-485) Port 1(RS-485) PLC 1 uses 9600 bps tDS-725 uses 9600 bps Serial Port Pair-connection Through the Ethernet PLC 2 uses 115200 bps tDS-715 uses 115200 bps Note: 1. PLC 1 and PLC 2 can use different baud rate and different data format at the same time when using pair-connection. But please make sure that the tDS-700 has the same setting as local serial devices. 2. The pair-connection can be created by using same or different tDS-700 models. The pair-connection is working as port-to-port. Virtual RS-485 Network (base on pair-connection) Serial Port Pair-connection Through the Ethernet Port 1 Port 1 RS-485 PLC Port 2 tDS-715 tDS-725 Port 1(RS-485) Serial Port Pair-connection Through the Ethernet Port 1 Port 2 PLC Port 2 (RS-485) Port 3 tDS-725 Meter tDS-735 RS-485 Port 1 (RS-485) Serial Port Pair-connection Through the Ethernet tDS-725 Port 2 (RS-485) Meter Note: When connecting several tDS-700 (RS-485 master) in RS-485 network, you should remove the pull-high/low resister in most of the tDS-700 modules, and make sure there is only one master in the RS-485 network. tDS-700 Web Configuration : Login Default Settings: Item Factory Default Settings IP 192.168.255.1 Gateway 192.168.0.1 Mask 255.255.0.0 Password Admin 22 tDS-700 Web Configuration : Home Page 23 tDS-700 Web Configuration : Network Setting 24 tDS-700 Web Configuration : Port Setting 25 tDS-700 Web Configuration : IP Filter tDS/tGW-700 Common Features Tiny Device Server tDS-700: Tiny Device Servers Tiny Modbus Gateway tGW-700: Tiny Modbus Gateway 27 tGW-700 Features Cost-effective Modbus/TCP to RTU/ASCII Gateway Supports Modbus/TCP master and slave Supports Modbus RTU/ASCII master and slave Supports pair-connection (serial-bridge, serial-tunnel) applications Tiny form-factor and low power consumption Modbus Gateway Basis Modbus/TCP Modbus RTU or Modbus ASCII Meter 10/100 M Ethernet Port 502 (COM1) RS-485 PLC Port 503 (COM2) RS-485 tGW-725 PLC Meter Note: 1. The tGW-700 act as Modbus/TCP to Modbus RTU/ASCII converter. The client program must use Modbus/TCP protocol. 2. The Modbus RTU or ASCII protocol, baud rate and data format used are depending on the serial devices, and are setting via web configuration. Modbus Gateway Application Modbus RTU or ASCII Modbus/TCP Port 502 RS-232 RFID Reader tGW-712 with Modbus RTU 10/100 M Ethernet Port 502 RS-485 PLC Meter tGW-715 with Modbus ASCII Port 502 Port 503 NS-208PSE Ethernet Switch with PoE tGW-725 RS-485 PLC RS-485 PLC Note: 1. The default TCP ports used in tGW-700 are 502 (COM1), 503 (COM2) and 504 (COM3). These TCP ports can be changed via the web configuration. Meter Meter Serial Port Pair-connection Basis Virtual RS-485 bus through the pair-connection. Port 1(RS-485) Port 1(RS-485) PLC 1 uses 115200 bps and Modbus RTU Serial Port Pair-connection Through the Ethernet tGW-715 uses 115200 bps and Modbus RTU PLC 2 uses 115200 bps and Modbus RTU tGW-715 uses 115200 bps and Modbus RTU Note: 1. PLC 1 and PLC 2 can communicate with each other via the RS-485 port that has pair-connection link through the Ethernet. Pair-connection with Different Protocols Virtual RS-485 bus through the pair-connection (with Modbus RTU to ASCII converter ). Port 1(RS-485) Port 1(RS-485) PLC 1 uses 9600 bps and Modbus RTU Serial Port Pair-connection Through the Ethernet tGW-715 uses 9600 bps and Modbus RTU PLC 2 uses 115200 bps and Modbus ASCII tGW-715 uses 115200 bps and Modbus ASCII Note: 1. PLC 1 and PLC 2 can use different protocol (RTU or ASCII), baud rate and data format at the same time when using pair-connection. But please make sure that the tGW-700 has the same setting as local serial devices. 2. The pair-connection can be created by using same or different tGW-700 models. The pair-connection is working as port-to-port. Virtual RS-485 Network (base on pair-connection) Serial Port Pair-connection Through the Ethernet Port 1 Port 1 RS-485 PLC tGW-715 with Modbus ASCII Port 2 tGW-725 Port 1(RS-485) Serial Port Pair-connection Through the Ethernet Port 1 Port 2 RS-485 with Modbus RTU/ASCII (Single Protocol) PLC Port 2 (RS-485) Port 3 tGW-735 Meter tGW-725 With Modbus RTU Port 1 (RS-485) Serial Port Pair-connection Through the Ethernet Port 2 (RS-485) Meter tGW-725 Note: When connecting several tGW-700 (RS-485 master) in RS-485 network, you should remove the pull-high/low resister in most of the tGW-700 modules, and make sure there is only one master in the RS-485 network. tGW-700 Web Configuration : Network Setting tGW-700 Web Configuration : Port Setting 35 Application : Pair Connection Q & A Thank You!! service@icpdas.com http://www.icpdas.com 37