Welcome to Unrestricted Construction Supervisor Exam Content Outline Subject Area Approx. Percent Approx. Test Questions Approx. % IRC Approx. IRC Questions Approx. % IBC Approx. IBC Questions Approx. IECC Questions Unrestricted Construction Supervisor Administrative Responsibilities 8% 6 5% 4 3% 2 General Building Construction Knowledge 11% 8 7% 5 4% 3 Energy Efficiency 6% 5 0% 0 0% 0 Accessibility 4% 3 3% 2 1% 1 Sitework & Foundations 7% 5 5% 3 2% 2 Concrete and Masonry 9% 7 6% 4 3% 2 Moisture Intrusion/Protection 7% 5 5% 3 2% 2 Structural Framing (Steel and Wood) 13% 10 8% 6 5% 3 Roofing/Exterior Walls 7% 5 5% 3 2% 2 Doors/Windows 5% 4 3% 2 2% 1 Interior Environment (Mechanical and Ventilation) 7% 5 5% 3 2% 2 Fire Protection (Mechanical) 5% 4 3% 2 2% 1 Safety (Construction Safety and Lead Remediation) 11% 8 7% 5 4% 3 5 6 Unrestricted Construction Supervisor Exam Content Outline Based on 200 Sample Questions Unrestricted Construction Supervisor Exam Content Outline Based on 200 Sample Questions Based on 200 Sample Questions Approx. Percent Approx. Test Questions Approx. % IRC Approx. IRC Questions Approx. % IBC Approx. IBC Questions Unrestricted Construction Supervisor Administrative Responsibilities 8% 16 5% 10 3% 6 General Building Construction Knowledge 11% 22 7% 14 4% 8 Energy Efficiency 6% 12 0% 0 0% 0 Accessibility 4% 8 3% 5 1% 3 Sitework & Foundations 7% 14 5% 9 2% 5 Concrete and Masonry 9% 18 6% 12 3% 6 Moisture Intrusion/Protection 7% 14 5% 9 2% 5 Structural Framing (Steel and Wood) 13% 26 8% 17 5% 9 Roofing/Exterior Walls 7% 14 5% 9 2% 5 Doors/Windows 5% 10 3% 7 2% 4 Interior Environment (Mechanical and Ventilation) 7% 14 5% 9 2% 5 Fire Protection (Mechanical) 5% 10 3% 7 2% 4 Safety (Construction Safety and Lead Remediation) 11% 22 7% 14 4% 8 Approx. IECC Questions 12 6 Sample Questions What is the minimum compressive strength in psi for a concrete basement slab with negligible weathering potential? A. 1500 B. 2000 C. 2500 D. 4000 What is the minimum compressive strength in psi for a concrete basement slab with negligible weathering potential? A. 1500 B. 2000 C. 2500 D. 4000 To find this answer we first look for keywords in the question. Basement slab tells us we are dealing with a residential application and using the IRC Basement slab also implies foundation so we go to the Foundations Chapter 4 From the question, concrete is the material. Materials for Foundations is Section R402.2 In Section R402.2, the description for concrete points us to Table R402.2. In Table R402.2, we see that for a basement slab with negligible weathering potential, the minimum compressive strength is 2,500 psi. The answer is located on Page 42 of the IRC. 2. An accessory structure is a structure not greater than ___ square feet A 1,000 B 2,000 C 3,000 D 4,000 2. An accessory structure is a structure not greater than ___ square feet A 1,000 B 2,000 C 3,000 D 4,000 Keywords - Accessory Structure A good pace to start for all questions is the index If you look in the index under Accessory Structure, it points to Section R202 In Section R202, we find the definition of an Accessory Structure to be a structure not greater than 3,000 square feet. The answer is located on Page 9 of the IRC. 3. What is the R Value insulation requirement for a residential floor in climate zone 3 A 13 B 19 C 30 D 38 3. What is the R Value insulation requirement for a residential floor in climate zone 3 A 13 B 19 C 30 D 38 Keywords - Insulation Requirement Climate Zone tells us we should look in the IECC Again, we first go to the index under Insulation Under insulation, there is a section for Requirements 402.1.1 In Section 402.1.1, we see Table 402.1.1 and look under the Floor Column in Climate Zone 3 and see that the R Value is 19. The answer is located on Page 27 of the IECC. 4. For a Means of Egress Door, what is the minimum width of each door opening in inches? A 24 B 28 C 32 D 36 4. For a Means of Egress Door, what is the minimum width of each door opening in inches? A 24 B 28 C 32 D 36 Keywords - Means of Egress Means of Egress tells us this is more of a Global Requirement and we would first look at the IBC In the Index, under Means of Egress, there is a Section for Doors Under the Door Section it points us to Section 1005.2 and then 1008 In Section 1005.2, we do not get our answer so we go to 1008 In Section 1008 under 1008.1.1 Size of Doors, we see that the minimum width for a Means of Egress Dorr is 32 inches. The answer is located on Page 224 of the IBC. 5. Exterior wood framing walls shall be a minimum of ___ grade wood. A Utility B2 C3 D4 5. Exterior wood framing walls shall be a minimum of ___ grade wood. A Utility B2 C3 D4 Keywords - Wood Walls There are not many commercial buildings with wood walls, so we'll first look in the IRC In the Index under Wood there is a Section called Walls which points us to R602 In Section R602.2 Grade, we see that Studs shall be a minimum of Grade 3. The answer is located on Page 146 of the IRC. Administrative Responsibilities 1. Which of the following is not considered work exempt from a permit? A Swings & Playground Equipment B Sidewalks C Fences less than 6 feet D Interior Painting 1. Which of the following is not considered work exempt from a permit? A Swings & Playground Equipment B Sidewalks C Fences less than 6 feet D Interior Painting Keywords - Permit Exempt From the index, Section R105 is Permits Section R105.2 is Work Exempt From the list you see the answer is C. The answer is located on Page 3 of the IRC. 2. A permit becomes invalid if the work authorized by the permit does not begin in ___ days. A 90 B 120 C 180 D 365 2. A permit becomes invalid if the work authorized by the permit does not begin in ___ days. A 90 B 120 C 180 D 365 Keywords - Permit, Days From the index, Section R105 is Permits Section R105.5 is Expiration From the definition you see the answer is C. The answer is located on Page 4 of the IRC. 3. The building permit shall be kept on site until the work is complete. A TRUE B FALSE 3. The building permit shall be kept on site until the work is complete. A TRUE B FALSE Keywords - Permit From the index, Section R105 is Permits Section R105.7 is Placement From the definition you see the statement is True. The answer is located on Page 4 of the IRC. 4. When shall a final inspection be conducted? A. B. C. D. After the permit is issued After permitted work is complete After the occupants move in Upon beginning the permitted work 4. When shall a final inspection be conducted? A. B. C. D. After the permit is issued After permitted work is complete After the occupants move in Upon beginning the permitted work Keywords - Final Inspection From the index, Section R109 is Inspections Section R109.1.6 is Final Inspection From the definition you see the answer is B. The answer is located on Page 6 of the IRC. 5. Which of the following is required in a Certificate of Occupancy? A. Name & Address of Owner B. Name of Building Official C. Edition of the Code permit was issued under D. All of the Above 5. Which of the following is required in a Certificate of Occupancy? A. Name & Address of Owner B. Name of Building Official C. Edition of the Code permit was issued under D. All of the Above Keywords - Certificate of Occupancy From the index, Section R110 is Certificate of Occupancy Section R110.3 is Certificate Issued From the list you see the answer is D. The answer is located on Page 7 of the IRC. 6. Which of the following is not required on a site plan? A. B. C. D. Location of new construction Distance from lot lines Traffic Control Plan Location of existing structures 6. Which of the following is not required on a site plan? A. B. C. D. Location of new construction Distance from lot lines Traffic Control Plan Location of existing structures Keywords - Site Plan (which is a construction document) From the index, Section R106 is Construction Documents Section R106.2 is Site Plan From the Definition you see the answer is C. The answer is located on Page 5 of the IRC. 7. How long must you retain approved construction documents after the work is completed? A. B. C. D. 30 Days 60 Days 90 Days 180 Days 7. How long must you retain approved construction documents after the work is completed? A. B. C. D. 30 Days 60 Days 90 Days 180 Days Keywords - Retain, Construction Documents From the index, Section R106 is Construction Documents Section R106.5 is Retention of Construction Documents From the Definition you see the answer is D. The answer is located on Page 5 of the IRC. 8. Who is authorized to establish a refund policy for permit fees? A. B. C. D. Building Official Owner Accountant Designer 8. Who is authorized to establish a refund policy for permit fees? A. B. C. D. Building Official Owner Accountant Designer Keywords - Refund, Permit From the index, Section R108 is Fees Section R108.5 is Refunds From the Definition you see the answer is A. The answer is located on Page 6 of the IRC. 9. You are allowed to continue work safely after a stop work order has been issued. A. TRUE B. FALSE 9. You are allowed to continue work safely after a stop work order has been issued. A. TRUE B. FALSE Keywords - Stop Work Order, Continue From the index, Section R114 is Stop Work Order Section R114.2 is Unlawful Continuance From the Definition you see the answer is B. The answer is located on Page 8 of the IRC. 10. Who appoints the building official from the Department of Building Safety? A. Owner of building B. Engineer on record C. Chief Appointing Authority of the Jurisdiction D. Mayor's Assistant of the Jurisdiction issuing permit 10. Who appoints the building official from the Department of Building Safety? A. Owner of building B. Engineer on record C. Chief Appointing Authority of the Jurisdiction D. Mayor's Assistant of the Jurisdiction issuing permit Keywords - Building Safety, Building Official, Appoints From the index, Section R103 is Dept of Building Safety Section R103.2 is Appointment From the Definition you see the answer is C. The answer is located on Page 1 of the IRC. IBC 11. When there is a conflict and different sections of the IBC specify different materials….. A. Use the less restrictive guidance B. Use the most restrictive guidance C. Use whichever material is readily available D. Use the more expensive option IBC 11. When there is a conflict and different sections of the IBC specify different materials….. A. Use the less restrictive guidance B. Use the most restrictive guidance C. Use whichever material is readily available D. Use the more expensive option This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 102.1 is General Applicability From this Section you see the answer is B. The answer is located on Page 1 of the IBC. IBC 12. Live loads for floors and roofs must be posted by the owner when they exceed ___ PSF A. B. C. D. 25 30 50 100 IBC 12. Live loads for floors and roofs must be posted by the owner when they exceed ___ PSF A. B. C. D. 25 30 50 100 Keywords - Floors and Roofs, Posted This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 106.1 is Floor and Roof Design Loads From this Section you see the answer is C. The answer is located on Page 5 of the IBC. IBC 13. A permit is not valid until… A. B. C. D. It is approved The fee has been paid It is posted at the site The site plan has been posted IBC 13. A permit is not valid until… A. B. C. D. It is approved The fee has been paid It is posted at the site The site plan has been posted Keywords - Permit This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 109 is Fees From this Section you see the answer is B. The answer is located on Page 6 of the IBC. IBC 14. Who has the authority to authorize temporary utility connections? A. B. C. D. Building Official Owner Engineer Designer IBC 14. Who has the authority to authorize temporary utility connections? A. B. C. D. Building Official Owner Engineer Designer Keywords - Permit This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 112 is Service Utilities From this Section you see the answer is A. The answer is located on Page 8 of the IBC. IBC 15. A detached 400 square foot storage shed does not require a permit. A. TRUE B. FALSE IBC 15. A detached 400 square foot storage shed does not require a permit. A. TRUE B. FALSE Keywords - Permit This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 105 is Permits and 105.2 is Permits work exempt from Permits From this Section you see the answer is B. The answer is located on Page 4 of the IBC. IBC 16. Footing and foundation inspections should occur… A. Prior to construction B. During the design phase C. After excavation is complete and rebar is installed D. After excavation is complete but prior to rebar installation IBC 16. Footing and foundation inspections should occur… A. Prior to construction B. During the design phase C. After excavation is complete and rebar is installed D. After excavation is complete but prior to rebar installation Keywords - Foundation Inspections This is a Global Administrative Question. Think IBC. From the index, Chapter 1 is Scope & Administration Section 110 is Inspections and 110.3.1 is Footing and Foundation Inspections From this Section you see the answer is C. The answer is located on Page 7 of the IBC. General Knowledge IRC 1. What is the maximum slope of a ramp? A. B. C. D. 4 to 1 8 to 1 10 to 1 12 to 1 IRC 1. What is the maximum slope of a ramp? A. B. C. D. 4 to 1 8 to 1 10 to 1 12 to 1 Keywords - Maximum Slope, Ramp From the index, Chapter 3 is Building Planning Section R311 is Means of Egress Section R311.8 is Ramps, and from Section R311.8.1 you see the answer is D. The answer is located on Page 61 of the IRC. IRC 2. A drill hole for piping or conduit shall be a minimum of __ inches from the top and bottom of the floor joist. A. B. C. D. 1 2 3 4 IRC 2. A drill hole for piping or conduit shall be a minimum of __ inches from the top and bottom of the floor joist. A. B. C. D. 1 2 3 4 Keywords - Drill hole for conduit, floor joist From the index, Chapter 5 is Floors Section R502 is Wood Floor Framing From Section R502.8 you see the answer is A. The answer is located on Page 114 of the IRC. IRC 3. After the 1st coat is applied, when should the 2nd coat of cement plaster be applied . A. B. C. D. 12 hrs 24 hrs 36 hrs 48 hrs IRC 3. After the 1st coat is applied, when should the 2nd coat of cement plaster be applied . A. B. C. D. 12 hrs 24 hrs 36 hrs 48 hrs Keywords - Cement Plaster, 2nd Coat From the index, Chapter 7 is Wall Covering Section R702 is Interior Covering Section R702.2 is Interior Plaster, and from Section R702.2.2 you see the answer is D. The answer is located on Page 359 of the IRC. IRC 4. Exhaust ducts associated with clothes dryers shall terminate outside of the building. A. TRUE B. FALSE IRC 4. Exhaust ducts associated with clothes dryers shall terminate outside of the building. A. TRUE B. FALSE Keywords - Exhaust Ducts, Dryers From the index, Chapter 15 is Exhaust Systems Section M1502 is Clothes Dryer Exhaust From Section M1502.3 you see the answer is A. The answer is located on Page 487 of the IRC. IRC 5. Electrical equipment intended to interrupt current at fault levels shall have a minimum interrupting rating of ___ amperes. A. B. C. D. 1 5,000 10,000 15,000 IRC 5. Electrical equipment intended to interrupt current at fault levels shall have a minimum interrupting rating of ___ amperes. A. B. C. D. 1 5,000 10,000 15,000 Keywords - Electrical Equipment, Interrupting Rating From the index, Chapter 34 is Electrical General Requirements Section E3404 is General Electrical Requirements From Section E3404.2 you see the answer is C. The answer is located on Page 646 of the IRC. IRC 6. All metal faceplates should be grounded. A. TRUE B. FALSE IRC 6. All metal faceplates should be grounded. A. TRUE B. FALSE Keywords - Metal Faceplate From the index, Chapter 40 is Devices and Luminaires Section E4002 is Receptacles From Section E4002.2 you see the answer is A. The answer is located on Page 706 of the IRC. IRC 7. Switching devices must be located less than 5 feet from the inside walls of the pool. A. TRUE B. FALSE IRC 7. Switching devices must be located less than 5 feet from the inside walls of the pool. A. TRUE B. FALSE Keywords - Switching Devices, Pool From the index, Chapter 42 is Swimming Pools Section E4203 is Equipment Location and Clearances From Section E4203.2 you see the answer is B. The answer is located on Page 715 of the IRC. IRC 8. In Massachusetts, which of the following counties is not in the high radon potential zone? A. B. C. D. Essex Berkshire Middlesex Worcester IRC 8. In Massachusetts, which of the following counties is not in the high radon potential zone? A. B. C. D. Essex Berkshire Middlesex Worcester Keywords - Massachusetts, High Radon From the index, Appendix F is Radon Control Methods From Table AF101(1) you see the answer is B. The answer is located on Page 787 of the IRC. IRC 9. Floor registers of vented floor furnaces shall be at least ___ inches from a wall. A. B. C. D. 4 6 12 16 IRC 9. Floor registers of vented floor furnaces shall be at least ___ inches from a wall. A. B. C. D. 4 6 12 16 Keywords - Vented Floor Furnace, Floor Register From the index, Chapter 14 is Heating and Cooling Equipment Section M1408 is Vented Floor Furnaces From Section M1408.3 you see the answer is A . The answer is located on Page 484 of the IRC. IRC 10. A dwelling less than 500 square feet need not have a shower. A. TRUE B. FALSE IRC 10. A dwelling less than 500 square feet need not have a shower. A. TRUE B. FALSE Keywords - Dwelling, Shower From the index, Chapter 3 is Building Planning Section R306 is Sanitation From Section R306.1 you see the answer is B. The answer is located on Page 55 of the IRC. IRC 11. What is the minimum clearance required in front of a toilet in inches? A. B. C. D. 18 21 24 28 IRC 11. What is the minimum clearance required in front of a toilet in inches? A. B. C. D. 18 21 24 28 Keywords - Clearance, Toilet From the index, Chapter 3 is Building Planning Section R307 is Toilet, Bath and Shower Spaces From Section R307.1 you see the answer is B. The answer is located on Page 55 of the IRC. IRC 12. A skylight is sloped at ___ degrees or more from vertical. A. B. C. D. 10 12 15 20 IRC 12. A skylight is sloped at ___ degrees or more from vertical. A. B. C. D. 10 12 15 20 Keywords - Skylight, Slope From the index, Chapter 3 is Building Planning Section R308 is Glazing Section R308.6 is Skylights and Sloped Glazing, and from Section R308.6.1 you see the answer is C. The answer is located on Page 57 of the IRC. IRC 13 Footings are not required to extend below the frost line when the monthly mean temperature of the area is ___ degrees Fahrenheit . A. B. C. D. 56 62 64 68 IRC 13 Footings are not required to extend below the frost line when the monthly mean temperature of the area is ___ degrees Fahrenheit . A. B. C. D. 56 62 64 68 Keywords - Footings, Frost From the index, Chapter 4 is Foundations Section R403 is Footings From Section R403.3 you see the answer is C. The answer is located on Page 78 of the IRC. IRC 14. Subsoil storm drains shall not be less than ___ inches in diameter. A. B. C. D. 3 4 6 8 IRC 14. Subsoil storm drains shall not be less than ___ inches in diameter. A. B. C. D. 3 4 6 8 Keywords - Subsoil Drains From the index, Chapter 33 is Storm Drainage Section P3302 is Subsoil Drains From Section P3302 you see the answer is B. The answer is located on Page 643 of the IRC. IBC 15. A vacation timeshare property is in Residential Group R. A. TRUE B. FALSE IBC 15. A vacation timeshare property is in Residential Group R. A. TRUE B. FALSE Keywords - Vacation Timeshare, Group R This is more of a global question, think IBC. From the index, Chapter 3 is Use and Occupancy Classification Section 310 is Residential Group R From Section 310.1 you see the answer is A. The answer is located on Page 35 of the IBC. IBC 16. If an unsafe condition is found, the building official can deliver a written notice by all of the following except.... A. B. C. D. by hand certified mail tape on door of building registered mail IBC 16. If an unsafe condition is found, the building official can deliver a written notice by all of the following except.... A. B. C. D. by hand certified mail tape on door of building registered mail Keywords - Unsafe Condition, Building Official This is more of a global question, think IBC. From the index, Chapter 1 is Scope and Administration Section R116 is Unsafe Structures and Equipment From Section 116.4 you see the answer is C. The answer is located on Page 9 of the IBC. IBC 17. In a Group H-5 Building, what is the minimum width of a service corridor must be 5 feet or ___ inches wider than the widest cart used in the corridor. A. B. C. D. 24 32 33 36 IBC 17. In a Group H-5 Building, what is the minimum width of a service corridor must be 5 feet or ___ inches wider than the widest cart used in the corridor. A. B. C. D. 24 32 33 36 Keywords - Minimum Width, Service Corridor This is more of a global question, think IBC. From the index, Chapter 4 is Special Detailed Requirements Section 415 is Groups H1 - H5 Section 415.8 is Groups H-5 and from Section 415.8.4.5 you see the answer is C. The answer is located on Page 71 of the IBC. IBC 18. What is the minimum height above and below a mezzanine structure in feet? A. B. C. D. 7 8 10 12 IBC 18. What is the minimum height above and below a mezzanine structure in feet? A. B. C. D. 7 8 10 12 Keywords - Minimum Height, Mezzanine Structure This is more of a global question, think IBC. From the index, Chapter 5 isGeneral Heights and Areas Section 505 is Mezzanines From Section 505.1 you see the answer is A. The answer is located on Page 81 of the IBC. IBC 19 Sprayed fire resistant materials are all of the following except… A. Cementitious B. Asphaltic C. Fibrous IBC 19 Sprayed fire resistant materials are all of the following except… A. Cementitious B. Asphaltic C. Fibrous Keywords - Sprayed Fire Resistant Materials This is more of a global question, think IBC. From the index, Chapter 17 is Structural Tests and Inspections Section 1702 is Definitions From this Section, you see the answer is B. The answer is located on Page 367 of the IBC. IBC 20. A report of a geotechnical investigation must contain all of the following except … A. B. C. D. Location of tests Soil profile Temperature during test Elevation of water table IBC 20. A report of a geotechnical investigation must contain all of the following except … A. B. C. D. Location of tests Soil profile Temperature during test Elevation of water table Keywords - Geotechnical Investigation This is more of a global question, think IBC. From the index, Chapter 18 is Soils and Foundations Section 1803 is Geotechnical Investigations From Section 1803.6, you see the answer is C. The answer is located on Page 389 of the IBC. IBC 21. What is the shear value in lbs per square foot for 1/2 inch gypsum board with framing spaced at 16" OC? A. B. C. D. 50 60 70 90 IBC 21. What is the shear value in lbs per square foot for 1/2 inch gypsum board with framing spaced at 16" OC? A. B. C. D. 50 60 70 90 Keywords - Shear Value, Gypsum Board This is more of a global question, think IBC. From the index, Chapter 25 is Gypsum and Plaster Section 2508 is Gypsum Construction From Section 2508.5, you see the answer is D. The answer is located on Page 531 of the IBC. IBC 22. What is the maximum slope limit for safety for permanent fill ? A. B. C. D. 1 to 1 2 to 1 3 to 1 4 to 1 IBC 22. What is the maximum slope limit for safety for permanent fill ? A. B. C. D. 1 to 1 2 to 1 3 to 1 4 to 1 Keywords - Slope Limit, Permanent Fill This is more of a global question, think IBC. From the index, Chapter 33 is Safeguards During Construction Section 3304 is Sitework From Section 3304.1.1, you see the answer is B Energy Efficiency IECC 1. What is the maximum interior design temperature used for heating load calculations? A. B. C. D. 68 72 75 78 IECC 1. What is the maximum interior design temperature used for heating load calculations? A. B. C. D. 68 72 75 78 Keywords - Design Temp (IECC) From the index, Chapter 3 is Design Conditions Section 302.1 is Interior Design Conditions From the definition you see the answer is B. The answer is located on Page 25 of the IECC. IECC 2. What is the maximum interior design temperature used for cooling load calculations? A. B. C. D. 68 72 75 78 IECC 2. What is the maximum interior design temperature used for cooling load calculations? A. B. C. D. 68 72 75 78 Keywords - Design Temp (IECC) From the index, Chapter 3 is Design Conditions Section 302.1 is Interior Design Conditions From the definition you see the answer is C. The answer is located on Page 25 of the IECC. IECC 3. Nebraska is located in the moist area of the US. A. TRUE B. FALSE IECC 3. Nebraska is located in the moist area of the US. A. TRUE B. FALSE Keywords - Nebraska, Moist Area (IECC) From the index, Section 301 is Climate Zone. Figure 301.1 is Climate Zones From the table you see the answer is A. The answer is located on Page 10 of the IECC. IECC 4. What is the R Value insulation requirement for a residential floor in climate zone 3. A. B. C. D. 13 19 30 38 IECC 4. What is the R Value insulation requirement for a residential floor in climate zone 3. A. B. C. D. 13 19 30 38 Keywords - R value, residential, climate zone (IECC) From the index, Section 402 is Building Thermal Envelope Table 402.1.1 is Insulation Requirements From the table you see the answer is B. The answer is located on Page 27 of the IECC. IECC 5. Pools heated to more than 90 degrees F shall have a pool cover with a minimum R value of? A. B. C. D. 8 10 12 14 IECC 5. Pools heated to more than 90 degrees F shall have a pool cover with a minimum R value of? A. B. C. D. 8 10 12 14 Keywords - R value, Pool (IECC) From the index, Section 403.9 is Pools Table 403.9.3 is Pool Covers From the definition you see the answer is C. The answer is located on Page 32 of the IECC. IECC 6. A duct tightness test is not required for an air handler if it is located in a conditioned space. A. TRUE B. FALSE IECC 6. A duct tightness test is not required for an air handler if it is located in a conditioned space. A. TRUE B. FALSE Keywords - Duct, Tightness (IECC) From the index, Section 403.2 is Ducts Table 403.2.2 is Sealing From the definition you see the answer is A . The answer is located on Page 31 of the IECC. IECC 7. Above grade walls are at least ___ % above grade. A. B. C. D. 50 60 70 85 IECC 7. Above grade walls are at least ___ % above grade. A. B. C. D. 50 60 70 85 Keywords - Walls, Above Grade (IECC) From the index, Section 202 is Walls From the definition you see the answer is A. The answer is located on Page 5 of the IECC. IECC 8. A curtain wall located in Climate Zone 3 requires a U-factor of? A. B. C. D. 0.5 0.6 0.7 1.2 IECC 8. A curtain wall located in Climate Zone 3 requires a U-factor of? A. B. C. D. 0.5 0.6 0.7 1.2 Keywords - Climate Zone 3, Curtain Wall, U-factor (IECC) From the index, Ufactor points you to 502 Table 502.3 is Building Envelope Requirements From the table you see the answer is B. The answer is located on Page 41 of the IECC. IECC 9. What is the minimum pipe insulation thickness in inches for a steam pipe greater than 1.5 inches in diameter? A. B. C. D. 1.5 2 3 4 IECC 9. What is the minimum pipe insulation thickness in inches for a steam pipe greater than 1.5 inches in diameter? A. B. C. D. 1.5 2 3 4 Keywords - Pipe insulation thickness, steam pipe (IECC) From the index, Section 503 is Building Mechanical Systems (steam pipe) Table 503.2.8 is Minimum Pipe Insulation From the table you see the answer is C. The answer is located on Page 51 of the IECC. IECC 10. Automatic lighting shutoff is required in buildings larger than ___ square feet. A. B. C. D. 2000 5000 10000 15000 IECC 10. Automatic lighting shutoff is required in buildings larger than ___ square feet. A. B. C. D. 2000 5000 10000 15000 Keywords - Automatic Lighting Shutoff (IECC) From the index, Section 505 is Lighting Systems. Section 505.2.2.2 is Automatic lighting Shutoff From the definition you see the answer is B. The answer is located on Page 58 of the IECC. IECC 11. A skylight is a glass material installed at a slope of ___ degrees or greater. A. B. C. D. 10 12 15 20 IECC 11. A skylight is a glass material installed at a slope of ___ degrees or greater. A. B. C. D. 10 12 15 20 Keywords - Skylight (IECC) From the index, Section 202 is Definitions From the definition you see the answer is C. The answer is located on Page 7 of the IECC. IECC 12. Supply ducts in attics shall be insulated to a minimum R value of? A. B. C. D. 4 6 8 10 IECC 12. Supply ducts in attics shall be insulated to a minimum R value of? A. B. C. D. 4 6 8 10 Keywords - Supply Duct, Attic, R value (IECC) From the index, Section 403.2 is Ducts and Section 403.2.1 is Insulation. From the definition you see the answer is C. The answer is located on Page 30 of the IECC. accessability IRC 1. Attics containing appliances do not need a clear opening an unobstructed passageway large enough for removal of the appliance. A. TRUE B. FALSE IRC 1. Attics containing appliances do not need a clear opening an unobstructed passageway large enough for removal of the appliance. A. TRUE B. FALSE Keywords - Attic, Clear opening (access), appliance From the index, Section M1305 is Access to Appliances Section M1305.1.3 is Appliances in Attics From the definition you see the answer is B. The answer is located on Page 477 of the IRC. IRC 2. An accessory structure is a structure not greater than ___ square feet. A. B. C. D. 1,000 2,000 3,000 4,000 IRC 2. An accessory structure is a structure not greater than ___ square feet. A. B. C. D. 1,000 2,000 3,000 4,000 Keywords - Accessory Structure From the index, Section R202 is Definitions From the definition you see the answer is C. The answer is located on Page 9 of the IRC. IRC 3. Plumbing fixtures with concealed slip joint connections must have an access panel at least ___ inches in diameter. A. B. C. D. 12 18 24 36 IRC 3. Plumbing fixtures with concealed slip joint connections must have an access panel at least ___ inches in diameter. A. B. C. D. 12 18 24 36 Keywords - Plumbing Fixture, Access Panel From the index, Section P2704 is Access to Plumbing Connections From the definition you see the answer is A. The answer is located on Page 595 of the IRC. IRC 4 The location of plumbing piping, fixtures and equipment shall not interfere with windows or doors. A. TRUE B. FALSE IRC 4 The location of plumbing piping, fixtures and equipment shall not interfere with windows or doors. A. TRUE B. FALSE Keywords - Plumbing Fixture, Interfere (Access) From the index, Section P2705 is Access to Plumbing Fixtures From the definition you see the answer is A. The answer is located on Page 595 of the IRC. IRC 5. A vented floor furnace shall have a trap door not less than ___ square feet. A. B. C. D. 3 4.6 5 6 IRC 5. A vented floor furnace shall have a trap door not less than ___ square feet. A. B. C. D. 3 4.6 5 6 Keywords - Vented Floor Furnace, Trap Door (Access) From the index, Chapter 14 is Heating and Cooling Equipment Section M1408.4 is Vented Floor Furnaces Access From the definition you see the answer is B. The answer is located on Page 484 of the IRC. IBC 6. At least 60% of all public entrances shall be accessible. A. TRUE B. FALSE IBC 6. At least 60% of all public entrances shall be accessible. A. TRUE B. FALSE Keywords - Public Entrances, Accessible This is a Global Accessibility Question. Think IBC. From the index, Chapter 11 is Accessibility Section 1105 is Accessible Entrances From this Section you see the answer is A. The answer is located on Page 259 of the IBC. IBC 7. For a parking lot with 160 spaces, ___ spaces must be accessible. A. B. C. D. 4 6 8 10 IBC 7. For a parking lot with 160 spaces, ___ spaces must be accessible. A. B. C. D. 4 6 8 10 Keywords - Parking, Accessible This is a Global Accessibility Question. Think IBC. From the index, Chapter 11 is Accessibility Section 1106 is Parking and Loading Facilities From this Section you see the answer is B. The answer is located on Page 260 of the IBC. IBC 8. In an assembly area with 75 seats, there must be ___ wheelchair spaces under Special Occupancy. A. B. C. D. 2 3 4 6 IBC 8. In an assembly area with 75 seats, there must be ___ wheelchair spaces under Special Occupancy. A. B. C. D. 2 3 4 6 Keywords - Assembly Area, Special Occupancy This is a Global Accessibility Question. Think IBC. From the index, Chapter 11 is Accessibility Section 1108 is Special Occupancy From this Section you see the answer is C. The answer is located on Page 264 of the IBC. Site work & Foundation IRC 1. Who determines if a soil test is required for a potential foundation locations? A. B. C. D. Construction Supervisor Building Official Designer Owner IRC 1. Who determines if a soil test is required for a potential foundation locations? A. B. C. D. Construction Supervisor Building Official Designer Owner Keywords - Soil Test, Foundation From the index, Chapter 4 is Foundations Section R401.4 is Soil Tests From the definition you see the answer is B. The answer is located on Page 71 of the IRC. IRC 2. 3,500 PSI equals ____ kPa? A. B. C. D. 7,000 1,750 507.6 24,132.50 IRC 2. 3,500 PSI equals ____ kPa? A. B. C. D. 7,000 1,750 507.6 24,132.50 Keywords - psi, kPa From the conversion factor listed in Table R402.2, 1 psi = 6.895 kPa Calculating the conversion gives you D. The answer is located on Page 72 of the IRC. IRC 3. What is the minimum size of a footing of a 2-story light-frame construction home on soil with a load bearing value of 2,000 psf? A. B. C. D. 12 in 15 in 17 in 23 in IRC 3. What is the minimum size of a footing of a 2-story light-frame construction home on soil with a load bearing value of 2,000 psf? A. B. C. D. 12 in 15 in 17 in 23 in Keywords - Footing, soil From the index, Chapter 4 is Foundations Section R403.1 is footings From the table you see the answer is A. The answer is located on Page 72 of the IRC. IRC 4. How should concrete be consolidated where stay-in-place forms are used for a foundation? A. B. C. D. With a Shovel Internal Vibration None Required Tamping IRC 4. How should concrete be consolidated where stay-in-place forms are used for a foundation? A. B. C. D. With a Shovel Internal Vibration None Required Tamping Keywords - Concrete, Foundation From the index, Chapter 4 is Foundations Section R404 is Foundation and Retaining Walls From Section R404.1.2.3.5 you see the answer is B. The answer is located on Page 95 of the IRC. IRC 5. Bracing is not required for wall supporting less than ____ feet of backfill. A. B. C. D. 2 3 4 5 IRC 5. Bracing is not required for wall supporting less than ____ feet of backfill. A. B. C. D. 2 3 4 5 Keywords - Bracing, Wall, Backfill From the index, Chapter 4 is Foundations Section R404 is Foundation and Retaining Walls From Section R404.1.7 you see the answer is C. The answer is located on Page 103 of the IRC. IRC 6. A sump is not required in a drainage system in _____ soils. A. B. C. D. Group 1 Group 2 Group 3 Group 4 IRC 6. A sump is not required in a drainage system in _____ soils. A. B. C. D. Group 1 Group 2 Group 3 Group 4 Keywords - Sump, Drainage System From the index, Chapter 4 is Foundations Section R405 is Foundation Drainage From Section R405.2.3 you see the answer is A. The answer is located on Page 107 of the IRC. IRC 7. Which of the following is not an acceptable concrete or foundation waterproofing system? A. B. C. D. 6 mil PVC 60 mil Flexible Polymer Cement Two-ply hot mopped felts 3 mil PVC IRC 7. Which of the following is not an acceptable concrete or foundation waterproofing system? A. B. C. D. 6 mil PVC 60 mil Flexible Polymer Cement Two-ply hot mopped felts 3 mil PVC Keywords - Foundation, Waterproofing From the index, Chapter 4 is Foundations Section R406 is Foundation Waterproofing and Damp proofing From Section R406.2 you see the answer is D. The answer is located on Page 107 of the IRC. IRC 8. Access to under floor spaces shall be at least ____ A. B. C. D. 3 sq ft 4 sq ft 5 sq ft 6 sq ft IRC 8. Access to under floor spaces shall be at least ____ A. B. C. D. 3 sq ft 4 sq ft 5 sq ft 6 sq ft Keywords - Under floor space From the index, Section R408 is Under Floor Spaces From Section R408.4 you see the answer is A. The answer is located on Page 108 of the IRC. IRC 9. What is the minimum depth to which exterior footings must be placed? A. B. C. D. 1 ft 2 ft 3 ft 4 ft IRC 9. What is the minimum depth to which exterior footings must be placed? A. B. C. D. 1 ft 2 ft 3 ft 4 ft Keywords - Exterior Footings From the index, Chapter 4 is Foundations Section R403.1 is footings From Section R403.1.4 you see the answer is A. The answer is located on Page 73 of the IRC. IBC 10. The floor and walls must be damp proofed when the ground water level is lowered and maintained less than 6 inches below the bottom floor foundation A. Yes B. No IBC 10. The floor and walls must be damp proofed when the ground water level is lowered and maintained less than 6 inches below the bottom floor foundation A. Yes B. No Keywords – Damp proofed, Groundwater, Foundation This is a Global Foundation Question. Think IBC. From the index, Chapter 18 is Soils and Foundations Section 1805 is Damping and Waterproofing From Section 1805.1.3 Groundwater Control you see the answer is A. The answer is located on Page 390 of the IBC. IBC 11. What is the minimum slope percentage for ground directly adjacent to the foundation? A. B. C. D. 2% 3% 5% 10% IBC 11. What is the minimum slope percentage for ground directly adjacent to the foundation? A. B. C. D. 2% 3% 5% 10% Keywords - Slope, Foundation This is a Global Foundation Question. Think IBC. From the index, Chapter 18 is Soils and Foundations Section 1804 is Excavation, Grading and Fill From Section 1804.3 Site Grading you see the answer is A. The answer is located on Page 389 of the IBC. IBC 12. Vertical reinforcement of a masonry foundation wall shall have a minimum yield strength of ____ psi. A. B. C. D. 20,000 40,000 60,000 80,000 IBC 12. Vertical reinforcement of a masonry foundation wall shall have a minimum yield strength of ____ psi. A. B. C. D. 20,000 40,000 60,000 80,000 Keywords - Masonry, Foundation, Yield Strength This is a Global Foundation Question. Think IBC. From the index, Chapter 18 is Soils and Foundations Section 1807 is Foundation Walls, Retaining Walls From Section 1807.1.6.3 Masonry Foundation Walls you see the answer is C. The answer is located on Page 394 of the IBC. IBC 13. What safety factor is used in the design of retaining walls? A. B. C. D. 1.5 2.5 3 3.5 IBC 13. What safety factor is used in the design of retaining walls? A. B. C. D. 1.5 2.5 3 3.5 Keywords - Safety Factor, Retaining Walls This is a Global Foundation Question. Think IBC. From the index, Chapter 18 is Soils and Foundations Section 1807 is Foundation Walls, Retaining Walls From Section 1807.2.3 Safety Factor you see the answer is A. The answer is located on Page 397 of the IBC. IBC 14. Backfill in the annular space surrounding retaining wall columns must be concrete with a compressive strength of at least ___ psi A. B. C. D. 2,000 3,000 4,000 5,000 IBC 14. Backfill in the annular space surrounding retaining wall columns must be concrete with a compressive strength of at least ___ psi A. B. C. D. 2,000 3,000 4,000 5,000 Keywords - Backfill, Retaining Walls This is a Global Foundation Question. Think IBC. From the index, Chapter 18 is Soils and Foundations Section 1807 is Foundation Walls, Retaining Walls From Section 1807.3.3 Backfill you see the answer is A. The answer is located on Page 398 of the IBC. Concrete & Masonry IRC 1. What is the minimum compressive strength in psi for a concrete basement slab with negligible weathering potential. A. B. C. D. 1500 2000 2500 4000 IRC 1. What is the minimum compressive strength in psi for a concrete basement slab with negligible weathering potential. A. B. C. D. 1500 2000 2500 4000 Keywords - Compressive Strength, Concrete Basement Slab From the index, Chapter 4 is Foundations Section R402 is Materials From Table R402.2 you see the answer is C. The answer is located on Page 72 of the IRC. IRC 2. All concrete used in precast foundations shall have a minimum compressive strength in psi of. A. B. C. D. 2,500 4,000 5,000 6,000 IRC 2. All concrete used in precast foundations shall have a minimum compressive strength in psi of. A. B. C. D. 2,500 4,000 5,000 6,000 Keywords - Precast Foundation, Compressive Strength From the index, Chapter 4 is Foundations Section R402 is Materials From Section R402.3.1 you see the answer is C. The answer is located on Page 72 of the IRC. IRC 3. For a below grade concrete floor, the 4 inches of base course must pass a __ inch sieve. A. B. C. D. 1 2 3 4 IRC 3. For a below grade concrete floor, the 4 inches of base course must pass a __ inch sieve. A. B. C. D. 1 2 3 4 Keywords - Concrete Floor, Below Grade From the index, Section R506 is Concrete Floors From Section 506.2.2 you see the answer is B. The answer is located on Page 144 of the IRC. IRC 4. The slump of concrete placed in removable forms shall not exceed _ inches. A. B. C. D. 3 4 6 8 IRC 4. The slump of concrete placed in removable forms shall not exceed _ inches. A. B. C. D. 3 4 6 8 Keywords - Concrete, Removable Forms From the index, Chapter 4 is Foundations Section R404 is Foundation and Retaining Walls From Section R404.1.2.3.4 you see the answer is C. The answer is located on Page 95 of the IRC. IRC 5. What is the minimum thickness of a rubble stone masonry wall in inches. A. B. C. D. 8 12 16 18 IRC 5. What is the minimum thickness of a rubble stone masonry wall in inches. A. B. C. D. 8 12 16 18 Keywords - Rubble Stone Masonry From the index, Section R606 is General Masonry Section R606.2.2 is Rubble Stone Masonry From this Section you see the answer is C. The answer is located on Page 261 of the IRC. IRC 6. What is the minimum thickness of a masonry bearing wall more than onestory high in inches. A. B. C. D. 8 12 16 18 IRC 6. What is the minimum thickness of a masonry bearing wall more than onestory high in inches. A. B. C. D. 8 12 16 18 Keywords - Masonry Bearing Wall, Minimum Thickness From the index, Section R606 is General Masonry Section R606.2.1 is Minimum Thickness From this Section you see the answer is A. The answer is located on Page 261 of the IRC. IRC 7. Chases and recesses in masonry walls shall not be deeper than ___ of the wall thickness. A. B. C. D. one quarter one third one half two thirds IRC 7. Chases and recesses in masonry walls shall not be deeper than ___ of the wall thickness. A. B. C. D. one quarter one third one half two thirds Keywords - Chases, Masonry From the index, Section R606 is General Masonry Section R606.7 is Chases From this Section you see the answer is B. The answer is located on Page 282 of the IRC. IRC 8. Masonry over openings can be supported by all of the following except. A. B. C. D. Steel lintels Reinforced concrete Grade 3 lumber masonry arches IRC 8. Masonry over openings can be supported by all of the following except. A. B. C. D. Steel lintels Reinforced concrete Grade 3 lumber masonry arches Keywords - Masonry over Openings (Lintels) From the index, Section R606 is General Masonry Section R606.10 is Lintels From this Section you see the answer is C. The answer is located on Page 263 of the IRC. IRC 9. When connecting a joist to a masonry wall, the bolt must be embedded at least ___ inches into the masonry wall. A. B. C. D. 2 3 4 6 IRC 9. When connecting a joist to a masonry wall, the bolt must be embedded at least ___ inches into the masonry wall. A. B. C. D. 2 3 4 6 Keywords - Masonry, Joist, Bolt From the index, Section R606 is General Masonry Section R606.11 is Anchorage From this Section you see the answer is C. The answer is located on Page 263 of the IRC. IRC 10. Grout for masonry shall consist of cementitious material and aggregate. A. Yes B. No IRC 10. Grout for masonry shall consist of cementitious material and aggregate. A. Yes B. No Keywords - Masonry, Grout From the index, Section R606 is General Masonry Section R609 is Grouted Masonry From this Section you see the answer is A. The answer is located on Page 271 of the IRC. IRC 11. What is the minimum reinforcing bar size for an 8 inch stacked bonded masonry wall? A. B. C. D. #3 #4 #5 #6 IRC 11. What is the minimum reinforcing bar size for an 8 inch stacked bonded masonry wall? A. B. C. D. #3 #4 #5 #6 Keywords - Rebar, Bonded Masonry Wall From the index, Section R606 is General Masonry Section R606 is General Masonry Construction and Table R606.12.4.2 From this Table you see the answer is C. The answer is located on Page 269 of the IRC. IRC 12. Pier Caps shall be capped with ___ inches of solid masonry. A. B. C. D. 2 4 6 8 IRC 12. Pier Caps shall be capped with ___ inches of solid masonry. A. B. C. D. 2 4 6 8 Keywords - Pier Cap, Masonry From the index, Section R606 is General Masonry Section R606.6.1 is Pier Cap From this Section you see the answer is B. The answer is located on Page 262 of the IRC. IBC 13. For concrete weathering probability, South Carolina is located in the ___ zone. A. Severe B. Moderate C. Negligible IBC 13. For concrete weathering probability, South Carolina is located in the ___ zone. A. Severe B. Moderate C. Negligible Keywords - Concrete Weathering This is a Global Concrete Question. Think IBC. From the index, Chapter 19 is Concrete Section 1904 is Durability Requirements From Section Figure 1904.3 you see the answer is B. The answer is located on Page 417 of the IBC. IBC 14. When using shotcrete, what is the maximum size of reinforcing bars? A. B. C. D. No. 3 No. 4 No. 5 No. 6 IBC 14. When using shotcrete, what is the maximum size of reinforcing bars? A. B. C. D. No. 3 No. 4 No. 5 No. 6 IBC 15. When taking strength tests of shotcrete, a sample must be taken at least every ___ yards. A. B. C. D. 10 15 20 50 IBC 15. When taking strength tests of shotcrete, a sample must be taken at least every ___ yards. A. B. C. D. 10 15 20 50 IBC 16. What is the allowable shear in lbs for a 1 inch bolt embedded 21 inches into adobe masonry. A. B. C. D. 300 400 500 600 IBC 16. What is the allowable shear in lbs for a 1 inch bolt embedded 21 inches into adobe masonry. A. B. C. D. 300 400 500 600 IBC 17. An interior masonry fireplace must have a clearance to combustibles of not less than ___ inches. A. B. C. D. 2 3 4 6 IBC 17. An interior masonry fireplace must have a clearance to combustibles of not less than ___ inches. A. B. C. D. 2 3 4 6 IBC 18 Hot weather construction provisions for masonry should be applied when the temperature exceeds ___ degrees Fahrenheit. A. B. C. D. 85 90 95 100 IBC 18 Hot weather construction provisions for masonry should be applied when the temperature exceeds ___ degrees Fahrenheit. A. B. C. D. 85 90 95 100 Moisture intrusion & Protection IRC 1. Vapor retarders are required on the interior side of basement walls in Zones 5,6,7,8 and Marine 4. A. TRUE B. FALSE IRC 1. Vapor retarders are required on the interior side of basement walls in Zones 5,6,7,8 and Marine 4. A. TRUE B. FALSE Keywords - Vapor Retarder, Basement Wall From the index, Section R601 is Vapor Retarders From this Section, you see the answer is B. The answer is located on Page 145 of the IRC. IRC 2. Which of the following does not meet material vapor retarder class specifications . A. B. C. D. Sheet polyethylene Fiberglass Batts Oil based paint Latex Paint IRC 2. Which of the following does not meet material vapor retarder class specifications . A. B. C. D. Sheet polyethylene Fiberglass Batts Oil based paint Latex Paint Keywords - Vapor Retarder, Class From the index, Section R601 is Vapor Retarders Section 601.3.2 is Material Class From this Section, you see the answer is C. The answer is located on Page 145 of the IRC. IRC 3. Spray foam applied to the interior cavity side shall have a minimum density of ___ lb per cubic foot to meet the insulating sheathing requirement . A. B. C. D. 2 3 4 6 IRC 3. Spray foam applied to the interior cavity side shall have a minimum density of ___ lb per cubic foot to meet the insulating sheathing requirement . A. B. C. D. 2 3 4 6 Keywords - Spray Foam, Insulating Sheathing From the index, Section R601 is Vapor Retarders Table 601.3.1 is Class III Vapor Retarders From the footnote of this Table, you see the answer is A. The answer is located on Page 145 of the IRC. IRC 4. Vapor retarders are not required on below grade walls in Zones 5,6,7,8 and Marine 4 . A. TRUE B. FALSE IRC 4. Vapor retarders are not required on below grade walls in Zones 5,6,7,8 and Marine 4 . A. TRUE B. FALSE Keywords - Vapor Retarder, Wall From the index, Section R601 is Vapor Retarders From this Section, you see the answer is A . The answer is located on Page 145 of the IRC. IRC 5. In zone 5, class III vapor retarders are permitted for all of the following except ... A. B. C. D. Vented cladding over OSB Vented cladding over plywood Vented cladding over sheathing Vented cladding over gypsum IRC 5. In zone 5, class III vapor retarders are permitted for all of the following except ... A. B. C. D. Vented cladding over OSB Vented cladding over plywood Vented cladding over sheathing Vented cladding over gypsum Keywords - Vapor Retarder From the index, Section R601 is Vapor Retarders Table 601.3.1 is Class III Vapor Retarders From this Table, you see the answer is C. The answer is located on Page 145 of the IRC. IRC 6. Vapor retarders are not required where moisture or freezing will not damage the materials in Zones 5,6,7,8 and Marine 4. A. TRUE B. FALSE IRC 6. Vapor retarders are not required where moisture or freezing will not damage the materials in Zones 5,6,7,8 and Marine 4. A. TRUE B. FALSE Keywords - Vapor Retarder From the index, Section R601 is Vapor Retarders From this Section, you see the answer is A. The answer is located on Page 145 of the IRC. IRC 7. Which of the following is not an acceptable concrete or foundation waterproofing system? A. B. C. D. 6 mil PVC 60 mil Flexible Polymer Cement Two-ply hot mopped felts 3 mil PVC IRC 7. Which of the following is not an acceptable concrete or foundation waterproofing system? A. B. C. D. 6 mil PVC 60 mil Flexible Polymer Cement Two-ply hot mopped felts 3 mil PVC Keywords - Foundation Waterproofing System From the index, Section R406 is Foundation Waterproofing Section R406.2 is Concrete and Masonry Waterproofing and Dampproofing From this Section, you see the answer is D. The answer is located on Page 107 of the IRC. IRC 8. For dampproofing, masonry walls shall not have less than ___ inches of portland cement parging applied to the exterior of the wall. A. B. C. D. (1/4) (1/2) (3/4) (3/8) IRC 8. For dampproofing, masonry walls shall not have less than ___ inches of portland cement parging applied to the exterior of the wall. A. B. C. D. (1/4) (1/2) (3/4) (3/8) Keywords - Damproofing, Masonry From the index, Section R406 is Foundation Waterproofing Section R406.2 is Concrete and Masonry Waterproofing and Dampproofing From this Section, you see the answer is D. The answer is located on Page 107 of the IRC. IRC 9. Polyethylene film applied for below grade moisture barriers must be overlapped by _ inches . A. B. C. D. 3 6 12 18 IRC 9. Polyethylene film applied for below grade moisture barriers must be overlapped by _ inches . A. B. C. D. 3 6 12 18 Keywords - Below Grade Moisture From the index, Section R406 is Foundation Waterproofing Section R406.3.2 is Below Grade Moisture Barrier From this Section, you see the answer is B. The answer is located on Page 107 of the IRC. IBC 10. Built in tubs with showers do not need waterproof joints between the tub and the wall. A. TRUE B. FALSE IBC 10. Built in tubs with showers do not need waterproof joints between the tub and the wall. A. TRUE B. FALSE Keywords - Showers, Waterproof Joints This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1210 is Surrounding Materials From Section 1210.4 you see the answer is B. The answer is located on Page 274 of the IBC. IBC 11. Exterior wall envelope test assemblies shall be at least ___ square feet . A. B. C. D. 24 32 36 42 IBC 11. Exterior wall envelope test assemblies shall be at least ___ square feet . A. B. C. D. 24 32 36 42 Keywords - Exterior Wall Envelope This is more of a global question, think IBC. From the index, Chapter 14 is Exterior Walls Section 1403 is Performance Requirements From Section 1403.2 you see the answer is B. The answer is located on Page 277 of the IBC IBC 12. Roof flashing shall have a minimum thickness of ___ inches . A. B. C. D. 0.015 0.019 0.025 0.030 IBC 12. Roof flashing shall have a minimum thickness of ___ inches . A. B. C. D. 0.015 0.019 0.025 0.030 Keywords - Roof Flashing This is more of a global question, think IBC. From the index, Chapter 15 is Roofing Section 1503 is Weather Protection From Section 1503.2 you see the answer is B. The answer is located on Page 288 of the IBC IBC 13. Fire retardant treated wood shall be dried to a moisture content of ___ % or less for structural panels . A. B. C. D. 12 15 19 22 IBC 13. Fire retardant treated wood shall be dried to a moisture content of ___ % or less for structural panels . A. B. C. D. 12 15 19 22 Keywords - Fire Retardant Wood, Moisture Content This is more of a global question, think IBC. From the index, Chapter 23 is Wood Section 2303 is Minimum Standards and Quality Section 2303.2 is Fire Retardant Treated Wood and from Section 2303.2.7 you see the answer is B. The answer is located on Page 454 of the IBC IBC 14. Dampproofing beneath a floor slab must be at least.... A. B. C. D. 3-mil 4-mil 6-ml 8-mil IBC 14. Dampproofing beneath a floor slab must be at least.... A. B. C. D. 3-mil 4-mil 6-ml 8-mil Keywords - Dampproofing, Floor Slab This is more of a global question, think IBC. From the index, Chapter 18 is Foundations Section 1805 is Dampproofing and Waterproofing Section 1805.2 is Dampproofing and from Section 1805.2.1 you see the answer is C. The answer is located on Page 390 of the IBC Structural Framing Steel & wood IRC 1. Load bearing cold fomed structural steel framing wall members shall not have the following info stamped. A. B. C. D. Manufacturer Minimum Coating Designation Minimum Length Minimum yield strength IRC 1. Load bearing cold fomed structural steel framing wall members shall not have the following info stamped. A. B. C. D. Manufacturer Minimum Coating Designation Minimum Length Minimum yield strength Keywords - Steel framing, wall, load bearing From the index, Chapter 6 is Wall Construction Section R603.2 is Structural Framing From Section R603.2.2 you see the answer is C. The answer is located on Page 188 of the IRC. IRC 2. What is the minimum screw size for fastening gypsum board to a cold formed structural steel wall? A. B. C. D. No. 5 No. 6 No. 7 No. 8 IRC 2. What is the minimum screw size for fastening gypsum board to a cold formed structural steel wall? A. B. C. D. No. 5 No. 6 No. 7 No. 8 Keywords - Screw, wall, gypsum, structural From the index, Chapter 6 is Wall Construction Section R603.2 is Structural Framing From Section R603.2.4 you see the answer is B. The answer is located on Page 188 of the IRC. IRC 3. Flanges and lips of load bearing cold formed steel roof framing members can be cut or notched if approved by the engineer. A. TRUE B. FALSE IRC 3. Flanges and lips of load bearing cold formed steel roof framing members can be cut or notched if approved by the engineer. A. TRUE B. FALSE Keywords - Flanges, Lips, steel roof From the index, Chapter 8 is Roof-Ceiling Construction Section R804 is Steel Roof Framing Section R804.3 is Roof Construction, and from Section R804.3.4 you see the answer is B. The answer is located on Page 420 of the IRC. IRC 4. Wall ties must be used on a structural steel roof assembly when the wind uplift pressure is greater than ___ pounds per square foot? . A. B. C. D. 15 20 25 30 IRC 4. Wall ties must be used on a structural steel roof assembly when the wind uplift pressure is greater than ___ pounds per square foot? . A. B. C. D. 15 20 25 30 Keywords - Structural steel roof, wind From the index, Chapter 8 is Roof-Ceiling Construction Section R804 is Steel Roof Framing Section R804.3 is Roof Construction, and from Section R804.3.9 you see the answer is B. The answer is located on Page 421 of the IRC. IRC 5. In a braced wall line using 1/2 inch gypsum board, what is the minimum spacing for nails and screws to be installed in inches . A. B. C. D. 7 8 12 16 IRC 5. In a braced wall line using 1/2 inch gypsum board, what is the minimum spacing for nails and screws to be installed in inches . A. B. C. D. 7 8 12 16 Keywords - Braced wall, gypsum, spacing From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing Section R602.10 is Wall Bracing, and from Section R602.10.2 you see the answer is A. The answer is located on Page 166 of the IRC. IRC 6. What is the minimum length in inches of a structural fiberboard braced wall panel on a 10 foot wall with a 85% opening clear height? A. B. C. D. 24 30 40 60 IRC 6. What is the minimum length in inches of a structural fiberboard braced wall panel on a 10 foot wall with a 85% opening clear height? A. B. C. D. 24 30 40 60 Keywords - Braced wall, fiberboard, structural From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing Section R602.10 is Wall Bracing, and from Table R602.10.5.2 you see the answer is A . The answer is located on Page 180 of the IRC. IRC 7. Steel Gable end walls less than 10 feet high must be anchored to the foundation or floor. A. TRUE B. FALSE IRC 7. Steel Gable end walls less than 10 feet high must be anchored to the foundation or floor. A. TRUE B. FALSE Keywords - Steel, gable end wall From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.3 is Wall Construction, and from Section R603.3.1.1 you see the answer is B. The answer is located on Page 191 of the IRC. IRC 8. On a steel wall, OSB structural sheathing materials shall be a minimum of ___ inches thick. A. B. C. D. (3/8) (7/16) (3/4) (1/2) IRC 8. On a steel wall, OSB structural sheathing materials shall be a minimum of ___ inches thick. A. B. C. D. (3/8) (7/16) (3/4) (1/2) Keywords - Steel wall, OSB, Structural From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.9 is Structural Sheathing, and from Section R603.9.1 you see the answer is B. The answer is located on Page 195 of the IRC. IRC 9. Steel framing members shall be replaced or special designed when the hole exceeds ___% of the flat width of the web . A. B. C. D. 40 50 60 70 IRC 9. Steel framing members shall be replaced or special designed when the hole exceeds ___% of the flat width of the web . A. B. C. D. 40 50 60 70 Keywords - Steel framing, hole From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.2 is Structural Framing, and from Section R603.2.5.3 you see the answer is D. The answer is located on Page 190 of the IRC. IRC 10. Load bearing steel framing can be shaped with steel complying with all of these ASTMs except . A. B. C. D. 563 653 792 1,003 IRC 10. Load bearing steel framing can be shaped with steel complying with all of these ASTMs except . A. B. C. D. 563 653 792 1,003 Keywords - Load bearing, Steel framing From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.2 is Structural Framing, and from Section R603.2.1 you see the answer is A . The answer is located on Page 188 of the IRC. IRC 11. What is the maximum length of a penetration of a structural steel member? A. B. C. D. 3 in 3.5 in 4 in 4.5 in IRC 11. What is the maximum length of a penetration of a structural steel member? A. B. C. D. 3 in 3.5 in 4 in 4.5 in Keywords - Structural steel From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.2 is Structural Framing, and from Section R603.2.5.1 you see the answer is D. The answer is located on Page 190 of the IRC. IRC 12. What is the minimum base steel thickness for a 43 mil structural steel member? A. B. C. D. 0.0329 0.0538 0.0428 0.0966 IRC 12. What is the minimum base steel thickness for a 43 mil structural steel member? A. B. C. D. 0.0329 0.0538 0.0428 0.0966 Keywords - Structural steel From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.2 is Structural Framing, and from Table R603.2(2) you see the answer is C. The answer is located on Page 189 of the IRC. IRC 13. What is the center to center spacing of web holes in steel wall studs? A. B. C. D. 12 in 16 in 20 in 24 in IRC 13. What is the center to center spacing of web holes in steel wall studs? A. B. C. D. 12 in 16 in 20 in 24 in Keywords - Steel wall From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.2 is Structural Framing, and from Section R603.2.5.1 you see the answer is D. The answer is located on Page 190 of the IRC. IRC 14. Lintels shall be provided for all openings greater than ___ feet in width. A. B. C. D. 2 3 4 6 IRC 14. Lintels shall be provided for all openings greater than ___ feet in width. A. B. C. D. 2 3 4 6 Keywords - Lintel, openings From the index, Chapter 6 is Wall Construction Section R611 is Exterior Concrete Wall Construction Section R611.8 is Requirements for Lintel openings, and from Section R611.8.2 you see the answer is A. The answer is located on Page 303 of the IRC. IRC 15. Load bearing headers are not required in interior nonbearing wood walls. A. TRUE B. FALSE IRC 15. Load bearing headers are not required in interior nonbearing wood walls. A. TRUE B. FALSE Keywords - Load bearing headers, wood walls From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing Section R602.7 is Headers, and from Section R602.7.2 you see the answer is A. The answer is located on Page 157 of the IRC. IRC 16. What is the recommended fastener spacing for built up corner studs in a wood wall? A. B. C. D. 12" OC 16" OC 20" OC 24" OC IRC 16. What is the recommended fastener spacing for built up corner studs in a wood wall? A. B. C. D. 12" OC 16" OC 20" OC 24" OC Keywords - Fastener spacing, wood wall From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing Section R602.3 is Design and Construction, and from Table R602.3(1) you see the answer is D. The answer is located on Page 153 of the IRC. IRC 17. What is the maximum tolerance for in line framing of steel studs? A. B. C. D. 1/4 inch 1/2 inch 3/4 inch 1 inch IRC 17. What is the maximum tolerance for in line framing of steel studs? A. B. C. D. 1/4 inch 1/2 inch 3/4 inch 1 inch Keywords - Tolerance, In Line Framing, Steel From the index, Chapter 6 is Wall Construction Section R603 is Steel Wall Framing Section R603.1 is General, and from Section R603.1.2 you see the answer is C. The answer is located on Page 187 of the IRC. IBC 18. Combustible wood framing shall be a minimum of ___ inches from flues and chimneys. A. B. C. D. 2 3 4 6 IBC 18. Combustible wood framing shall be a minimum of ___ inches from flues and chimneys. A. B. C. D. 2 3 4 6 Keywords - Combustible Wood Framing, Chimneys This is more of a global question, think IBC. From the index, Chapter 23 is Wood Section 2304 is General Construction Requirements From Section 2304.5 you see the answer is A. The answer is located on Page 456 of the IBC. IBC 19. Cold Formed floor and roof steel framing shall be in accordance with which of the following . A. B. C. D. AISI S200 AISI S150 AISI S210 AISI S300 IBC 19. Cold Formed floor and roof steel framing shall be in accordance with which of the following . A. B. C. D. AISI S200 AISI S150 AISI S210 AISI S300 Keywords - Steel Framing This is more of a global question, think IBC. From the index, Chapter 22 is Steel Section 2210 is Cold Formed Steel Light Frame Construction From Section 2210.5 you see the answer is C. The answer is located on Page 449 of the IBC. IBC 20. A registered design professional must be consulted for cold formed steel trusses spanning __ feet or greater . A. B. C. D. 30 40 50 60 IBC 20. A registered design professional must be consulted for cold formed steel trusses spanning __ feet or greater . A. B. C. D. 30 40 50 60 Keywords - Cold Formed Steel Trusses This is more of a global question, think IBC. From the index, Chapter 22 is Steel Section 2210 is Cold Formed Steel Light Frame Construction Section 2210.3 is Trusses and from Section 2210.3.4 you see the answer is D. The answer is located on Page 449 of the IBC. IBC 21. Special loads for steel joists include all of the following except . A. B. C. D. Bending moments End moments Concentrated loads Non-uniform loads IBC 21. Special loads for steel joists include all of the following except . A. B. C. D. Bending moments End moments Concentrated loads Non-uniform loads Keywords - Steel Joists, Special Loads This is more of a global question, think IBC. From the index, Chapter 22 is Steel Section 2206 is Steel Joists From Section 2206.2 you see the answer is A. The answer is located on Page 448 of the IBC. IBC 22. Steel placement plans need not include… A. B. C. D. Applicable loads Deflection criteria Joist Headers Design professional signature IBC 22. Steel placement plans need not include… A. B. C. D. Applicable loads Deflection criteria Joist Headers Design professional signature Keywords - Steel Placement Plan This is more of a global question, think IBC. From the index, Chapter 22 is Steel Section 2206 is Steel Joists From Section 2206.4 you see the answer is D. The answer is located on Page 448 of the IBC. IBC 23. Prescriptive framing for cold formed steel includes detached 1 and 2 family dwellings and townhouses. A. TRUE B. FALSE IBC 23. Prescriptive framing for cold formed steel includes detached 1 and 2 family dwellings and townhouses. A. TRUE B. FALSE Keywords - Prescriptive Steel Framing This is more of a global question, think IBC. From the index, Chapter 22 is Steel Section 2210 is Cold Formed Steel Light Frame Construction From Section 2210.7 you see the answer is A. The answer is located on Page 449 of the IBC. IBC 24. Framing members for each individual pane of glass must have a deflection of less than ___ of the glass edge length . A. B. C. D. (1/100) (1/150) (1/175) (1/200) IBC 24. Framing members for each individual pane of glass must have a deflection of less than ___ of the glass edge length . A. B. C. D. (1/100) (1/150) (1/175) (1/200) Keywords - Framing Members, Glass This is more of a global question, think IBC. From the index, Chapter 24 is Glass and Glazing Section 2403 is General Requirements for Glass From Section 2403.3 you see the answer is C. The answer is located on Page 521 of the IBC. IBC 25. An example of a structural composite lumber is ... A. B. C. D. LVL 2x6 2x8 2 x 12 IBC 25. An example of a structural composite lumber is ... A. B. C. D. LVL 2x6 2x8 2 x 12 Keywords - Structural Composite Lumber This is more of a global question, think IBC. From the index, Chapter 23 is Wood Section 2302 is Definitions From this Section, you see the answer is A . The answer is located on Page 452 of the IBC. IBC 26. Structural log members must have a grade mark of an approved lumber grading agency. A. TRUE B. FALSE IBC 26. Structural log members must have a grade mark of an approved lumber grading agency. A. TRUE B. FALSE Keywords - Structural Log Members, Grade Mark This is more of a global question, think IBC. From the index, Chapter 23 is Wood Section 2303.1 is Minimum Standards and Quality Section 2303.1 is General and from Section 2303.1.10 you see the answer is A. The answer is located on Page 453 of the IBC. Doors & Windows IRC 1. How many egress doors must be provided for each dwelling unit? A. B. C. D. 1 2 3 4 IRC 1. How many egress doors must be provided for each dwelling unit? A. B. C. D. 1 2 3 4 Keywords - Egress, Doors From the index, Chapter 3 is Building Planning Section R311 is Egress From Section R311.2 you see the answer is A. The answer is located on Page 59 of the IRC. IRC 2. What is the minimum length of the landing on either side of an exterior door? A. B. C. D. 20 in 24 in 36 in 48 in IRC 2. What is the minimum length of the landing on either side of an exterior door? A. B. C. D. 20 in 24 in 36 in 48 in Keywords - Landing, exterior door From the index, Chapter 3 is Building Planning Section R311 is Egress From Section R311.3 you see the answer is C. The answer is located on Page 59 of the IRC. IRC 3. Storm and screen doors are permitted to swing over exterior stairs ? A. TRUE B. FALSE IRC 3. Storm and screen doors are permitted to swing over exterior stairs ? A. TRUE B. FALSE Keywords - Storm Doors, stairs From the index, Chapter 3 is Building Planning Section R311 is Egress From Section R311.3.3.3 you see the answer is A. The answer is located on Page 59 of the IRC. IRC 4. Release of a window opening device shall require no more than ____ pounds of force. A. B. C. D. 10 12 15 20 IRC 4. Release of a window opening device shall require no more than ____ pounds of force. A. B. C. D. 10 12 15 20 Keywords - Window opening device In the IRC, Exterior Windows and Doors fall under Wall Construction. From the index, Chapter 6 is Wall Construction Section R612 is Exterior Windows and Doors Section R612.4 is Window Opening limiting devices, and from Section R612.4.2 you see the answer is C. The answer is located on Page 345 of the IRC. IRC 5. What is the structural safety factor for mullions? A. B. C. D. 1.5 2 2.5 3 IRC 5. What is the structural safety factor for mullions? A. B. C. D. 1.5 2 2.5 3 Keywords - Safety Factor, Mullions In the IRC, Exterior Windows and Doors fall under Wall Construction. From the index, Chapter 6 is Wall Construction Section R612 is Exterior Windows and Doors Section R612.11 is Mullions, and from Section R612.11.3 you see the answer is A. The answer is located on Page 348 of the IRC. IRC 6. Decorative glazed windows and doors must be tested by an approved independent laboratory. A. TRUE B. FALSE IRC 6. Decorative glazed windows and doors must be tested by an approved independent laboratory. A. TRUE B. FALSE Keywords - Glazed windows and doors In the IRC, Exterior Windows and Doors fall under Wall Construction. From the index, Chapter 6 is Wall Construction Section R612 is Exterior Windows and Doors From Section R612.6 you see the answer is B. The answer is located on Page 345 of the IRC. IRC 7. Windows and glass doors can be anchored through all of the following except... A. B. C. D. frame frame clip flange opening substrate IRC 7. Windows and glass doors can be anchored through all of the following except... A. B. C. D. frame frame clip flange opening substrate Keywords - Windows and glass doors, Anchored In the IRC, Exterior Windows and Doors fall under Wall Construction. From the index, Chapter 6 is Wall Construction Section R612 is Exterior Windows and Doors Section R612.10 is Anchorage Methods, and from Section R612.10.2.2 you see the answer is D. The answer is located on Page 347 of the IRC. IBC 8. For a Means of Egress Door, what is the minimum width of each door opening in inches? A. B. C. D. 24 28 32 36 IBC 8. For a Means of Egress Door, what is the minimum width of each door opening in inches? A. B. C. D. 24 28 32 36 Keywords - Means of Egress door, minimum width This is more of a global question, think IBC. From the index, Chapter 10 is Means of Egress Section 1008 is Doors, Gates and Turnstiles From Section 1008.1.1 you see the answer is C. The answer is located on Page 224 of the IBC. IBC 9. What is the minimum distance between two doors in a series in inches? A. B. C. D. 36 48 60 72 IBC 9. What is the minimum distance between two doors in a series in inches? A. B. C. D. 36 48 60 72 Keywords - Doors, minimum distance This is more of a global question, think IBC. From the index, Chapter 10 is Means of Egress Section 1008 is Doors, Gates and Turnstiles From Section 1008.1.8 you see the answer is B. The answer is located on Page 227 of the IBC. IBC 10. What is the minimum horizontal area of an emergency window well in square feet? A. B. C. D. 6 8 9 12 IBC 10. What is the minimum horizontal area of an emergency window well in square feet? A. B. C. D. 6 8 9 12 Keywords - Emergency window, minimum horizontal area This is more of a global question, think IBC. From the index, Chapter 10 is Means of Egress Section 1029 is Emergency Escape and Rescue From Section 1029.5.1 you see the answer is C. The answer is located on Page 255 of the IBC IBC 11. When considering lighting, what is the minimum net glazed area shall not be less than ___ percent of the floor area of the room served. A. B. C. D. 8 10 15 25 IBC 11. When considering lighting, what is the minimum net glazed area shall not be less than ___ percent of the floor area of the room served. A. B. C. D. 8 10 15 25 Keywords - floor area, minimum net glazed area This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1205 is Lighting From Section 1205.2 you see the answer is A. The answer is located on Page 272 of the IBC Roofing & Exterior walls IRC 1. Exterior wood framing walls shall be a minimum of ___ grade wood . A. B. C. D. Utility 2 3 4 IRC 1. Exterior wood framing walls shall be a minimum of ___ grade wood . A. B. C. D. Utility 2 3 4 Keywords - Wood Framing, Grade From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing From Section R602.2 Grade, you see the answer is C. The answer is located on Page 146 of the IRC. IRC 2 Any stud in an exterior wall may be notched to a depth not exceeding ___ percent of the width of the stud. A. B. C. D. 15 20 25 30 IRC 2 Any stud in an exterior wall may be notched to a depth not exceeding ___ percent of the width of the stud. A. B. C. D. 15 20 25 30 Keywords - Exterior Wall, notched From the index, Chapter 6 is Wall Construction Section R602 is Wood Wall Framing From Section R602.6 Grade, you see the answer is C. The answer is located on Page 155 of the IRC. IRC 3. Galvanized fasteners shall be used for attaching metal roof panels to supports . A. TRUE B. FALSE IRC 3. Galvanized fasteners shall be used for attaching metal roof panels to supports . A. TRUE B. FALSE Keywords - Fasteners, Metal Roof Panels From the index, Chapter 9 is Roof Assemblies Section R905 is Requirements for Roof Coverings Section 905.10 is Metal Roof Panels and from Section R905.10.4 you see the answer is A. The answer is located on Page 441 of the IRC. IRC 4. Steel roof trusses shall be connected to a load bearing wall with No. ___ screws . A. B. C. D. 8 10 12 15 IRC 4. Steel roof trusses shall be connected to a load bearing wall with No. ___ screws . A. B. C. D. 8 10 12 15 Keywords - Steel Roof Trusses, Screws From the index, Chapter 8 is RoofCeiling Construction Section R804 is Steel Roof Framing Section 804.3 is Roof Construction and from Section R804.3.7 you see the answer is B. The answer is located on Page 421 of the IRC. IRC 5. Wood trusses can be cut or notched if approved by a design professional. A. TRUE B. FALSE IRC 5. Wood trusses can be cut or notched if approved by a design professional. A. TRUE B. FALSE Keywords - Wood Trusses, Notched From the index, Chapter 8 is RoofCeiling Construction Section R802 is Wood Roof Framing Section 802.10 is Wood Trusses and from Section R802.10.4 you see the answer is A. The answer is located on Page 376 of the IRC. IRC 6. For hydronic piping applications, PEX tubing has a maximum hanger horizontal spacing of ___ feet . A. B. C. D. 2 2.67 3 4 IRC 6. For hydronic piping applications, PEX tubing has a maximum hanger horizontal spacing of ___ feet . A. B. C. D. 2 2.67 3 4 Keywords - Hydronic Piping, PEX Tubing From the index, Chapter 21 is Hydronic Piping Section M2101 is Hydronic Piping Systems installation From Table M2101.9 you see the answer is B. The answer is located on Page 507 of the IRC. IRC 7. A gas sauna heater must be equipped with a thermostat that limits room temperature to ___ degrees Fahrenheit . A. B. C. D. 100 110 120 194 IRC 7. A gas sauna heater must be equipped with a thermostat that limits room temperature to ___ degrees Fahrenheit . A. B. C. D. 100 110 120 194 Keywords - Gas, Sauna From the index, Chapter 24 is Fuel Gas Section G2440 is Sauna Heaters Section G2440.6 is Heat and Time Controls from this Section you see the answer is D. The answer is located on Page 584 of the IRC. IRC 8. What is the maximum ceiling joist span in feet for #3 Southern Pine (2x6) with a 16 inch ceiling joist spacing? A. B. C. D. 18ft 1 in 17ft 8 in 14ft 9 in 18ft 5 in IRC 8. What is the maximum ceiling joist span in feet for #3 Southern Pine (2x6) with a 16 inch ceiling joist spacing? A. B. C. D. 18ft 1 in 17ft 8 in 14ft 9 in 18ft 5 in Keywords - Ceiling Joist Span, Southern Pine From the index, Chapter 8 is RoofCeiling Construction Section R802 is Wood Roof Framing Section 802.4 is Allowable Ceiling Joist Spans and from Table R802.4(1) you see the answer is C. The answer is located on Page 377 of the IRC. IRC 9. What is the maximum opening in feet for a steel roof? A. B. C. D. 2 3 4 6 IRC 9. What is the maximum opening in feet for a steel roof? A. B. C. D. 2 3 4 6 Keywords - Steel Roof, Maximum Opening From the index, Chapter 8 is RoofCeiling Construction Section R804 is Steel Roof Framing Section 804.3 is Steel Roof Framing and from Section R804.3.6(1) you see the answer is C. The answer is located on Page 420 of the IRC. IBC 10. Fire Protection - What is the equivalent opening factor for a 1000 degree Fahrenheit exposed surface for 1 hour ? A. B. C. D. 0.1 0.2 0.3 0.5 IBC 10. Fire Protection - What is the equivalent opening factor for a 1000 degree Fahrenheit exposed surface for 1 hour ? A. B. C. D. 0.1 0.2 0.3 0.5 Keywords - Fire Protection, Opening Factor This is more of a global question, think IBC. From the index, Chapter 7 is Fire Resistant Construction Section 705 is Exterior Walls From Section 705.7 you see the answer is B. The answer is located on Page 97 of the IBC. IBC 11. The maximum length of any section of exterior structural glass veneer is ___ inches. A. B. C. D. 24 36 48 60 IBC 11. The maximum length of any section of exterior structural glass veneer is ___ inches. A. B. C. D. 24 36 48 60 Keywords - Exterior Structural Glass, Length This is more of a global question, think IBC. From the index, Chapter 14 is Exterior Walls Section 1405 is Installation of Wall Coverings Section 1405.12 is Glass Veneer and from Section 1405.12.1 you see the answer is C. The answer is located on Page 281 of the IBC. IBC 12. Roofs and roof covering materials must be compatible with each other . A. TRUE B. FALSE IBC 12. Roofs and roof covering materials must be compatible with each other . A. TRUE B. FALSE Keywords - Roofs, Covering Materials This is more of a global question, think IBC. From the index, Chapter 15 is Roofing Section 1506 is Materials From Section 1506.2 you see the answer is A. The answer is located on Page 289 of the IBC. IBC 13. Parapet walls should be coped with materials with a minimum width of ___ times the thickness of the wall . A. B. C. D. 1 1.5 2 2.5 IBC 13. Parapet walls should be coped with materials with a minimum width of ___ times the thickness of the wall . A. B. C. D. 1 1.5 2 2.5 Keywords - Parapet Walls, Coped This is more of a global question, think IBC. From the index, Chapter 15 is Roofing Section 1503 is Weather Protection From Section 1503.3 you see the answer is A. The answer is located on Page 288 of the IBC. IBC 14. What is the minimum drip edge overlap (inches) at the eaves and gables of shingle roofs? A. B. C. D. 1 2 3 4 IBC 14. What is the minimum drip edge overlap (inches) at the eaves and gables of shingle roofs? A. B. C. D. 1 2 3 4 Keywords - Drip Edge, gables, shingle roofs This is more of a global question, think IBC. From the index, Chapter 15 is Roofing Section 1507 is Requirement for Roof Coverings Section 1507.2 is Asphalt Shingles and from Section 1507.2.9.3 you see the answer is B. The answer is located on Page 291 of the IBC. Interior Environment IRC 1. An open vent terminal from a drainage system shall not be located less than ___ fet directly beneath any door. A. B. C. D. 1 2 3 4 IRC 1. An open vent terminal from a drainage system shall not be located less than ___ feet directly beneath any door. A. B. C. D. 1 2 3 4 Keywords - Open Vent Terminal, Drainage System From the index, Chapter 31 is Vents Section P3103 is Vent Terminals From Section P3103.5, Location of Vent Terminal, you see the answer is D. The answer is located on Page 635 of the IRC. IRC 2. A 2 inch diameter waste and vent pipe connecting to a horizontal branch or stack can serve ___ fixture units . A. B. C. D. 3 4 6 12 IRC 2. A 2 inch diameter waste and vent pipe connecting to a horizontal branch or stack can serve ___ fixture units . A. B. C. D. 3 4 6 12 Keywords - Waste and Vent Pipe, Horizontal Branch From the index, Chapter 31 is Vents Section P3111 is Combination Waste and Vent System From Section P3111.3, Size, you see the answer is A. The answer is located on Page 638 of the IRC. IRC 3. Unused openings in any chimney venting system should be closed or capped. A. TRUE B. FALSE IRC 3. Unused openings in any chimney venting system should be closed or capped. A. TRUE B. FALSE Keywords - Unused Openings, Venting System From the index, Chapter 18 is Chimneys and Vents Section M1801 is General From Section M1801.10, you see the answer is A. The answer is located on Page 497 of the IRC. IRC 4. Relief valves installed on water heaters shall be set to open at least ___ psi above operating pressure . A. B. C. D. 25 50 75 100 IRC 4. Relief valves installed on water heaters shall be set to open at least ___ psi above operating pressure . A. B. C. D. 25 50 75 100 Keywords - Relief Valves, Water Heaters From the index, Chapter 28 is Water Heaters Section P2803 is Relief Valves From Section P2803.3, you see the answer is A. The answer is located on Page 641 of the IRC. IRC 5. Metal ducts shall be supported by 1/2 inch wide 18-gage metal straps or … A. B. C. D. 10-gage galvanized wire 12-gage galvanized wire 16-gage galvanized wire 18-gage galvanized wire IRC 5. Metal ducts shall be supported by 1/2 inch wide 18-gage metal straps or … A. B. C. D. 10-gage galvanized wire 12-gage galvanized wire 16-gage galvanized wire 18-gage galvanized wire Keywords - Metal Ducts, Support From the index, Chapter 16 is Duct Systems Section M1601 is Duct Construction Section 1601.4 is Installation and from Section M1601.4.3, you see the answer is B. The answer is located on Page 492 of the IRC. IRC 6. For PVC hydronic piping, what is the maximum horizontal spacing interval in feet? A. B. C. D. 2.67 3 4 6 IRC 6. For PVC hydronic piping, what is the maximum horizontal spacing interval in feet? A. B. C. D. 2.67 3 4 6 Keywords - Hydronic Piping, Horizontal Spacing From the index, Chapter 21 is Hydronic Piping Section M2101 is Hydronic Piping Systems installation From Table M2101.9 you see the answer is C. The answer is located on Page 505 of the IRC. IRC 7. Ducts should take return air from inside the dwelling. A. TRUE B. FALSE IRC 7. Ducts should take return air from inside the dwelling. A. TRUE B. FALSE Keywords - Ducts, Return Air From the index, Chapter 16 is Duct Systems Section M1602 is Return Air From Section M1601.1, you see the answer is A. The answer is located on Page 491 of the IRC. IRC 8. Excavations for appliance installation shall extend to a depth of ___ inches below the appliance . A. B. C. D. 6 12 16 18 IRC 8. Excavations for appliance installation shall extend to a depth of ___ inches below the appliance . A. B. C. D. 6 12 16 18 Keywords - Excavation, Appliance From the index, Chapter 13 is Geneal mechanical System Requirements Section M1305 is Appliance Access Section M1305.1.4.2 Excavations, you see the answer is A. The answer is located on Page 478 of the IRC. IRC 9. For gas appliances connected by rigid metallic piping, a union must be installed within ___ feet of the appliance . A. B. C. D. 2 3 4 6 IRC 9. For gas appliances connected by rigid metallic piping, a union must be installed within ___ feet of the appliance . A. B. C. D. 2 3 4 6 Keywords - Gas Appliances, Union From the index, Chapter 24 is Fuel Gas Section G2422 is Appliance Connections Section G2422.1.4 is Unions from this Section you see the answer is D. The answer is located on Page 557 of the IRC. IBC 10. Cross ventilation must be provided for under floor space . A. TRUE B. FALSE IBC 10. Cross ventilation must be provided for under floor space . A. TRUE B. FALSE Keywords - Cross Ventilation, Under floor space This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1203 is Ventilation From Section 1203.3 you see the answer is A. The answer is located on Page 271 of the IBC. IBC 11. Ventilation openings are not required where mechanical ventilation is provided continuously at ___ cubic feet per minute . A. B. C. D. 1 2 3 4 IBC 11. Ventilation openings are not required where mechanical ventilation is provided continuously at ___ cubic feet per minute . A. B. C. D. 1 2 3 4 Keywords - Ventilation openings, Mechanical ventilation This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1203 is Ventilation From Section 1203.3.2 you see the answer is A. The answer is located on Page 271 of the IBC. IBC 12. What is the minimum height of a furred ceiling in feet? A. B. C. D. 7 8 9 10 IBC 12. What is the minimum height of a furred ceiling in feet? A. B. C. D. 7 8 9 10 Keywords - Minimum Height, Furred Ceiling This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1208 is Interior Space Dimensions From Section 1208.2.1 Furred Ceiling you see the answer is A. The answer is located on Page 273 of the IBC. IBC 13. Interior spaces meant for human occupancy must have a space heating system capable of maintaining ___ degrees at 3 feet above floor level. A. B. C. D. 62 65 68 72 IBC 13. Interior spaces meant for human occupancy must have a space heating system capable of maintaining ___ degrees at 3 feet above floor level. A. B. C. D. 62 65 68 72 Keywords - Interior Spaces, Space heating This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1204 is Temperature Control From Section 1204.1 Equipment and Systems you see the answer is C. The answer is located on Page 272 of the IBC. IBC 14. Walls, partitions and floor/ceiling assemblies separating dwelling units must have a sound transmission class of no less than ___ if field tested . A. B. C. D. 45 50 55 60 IBC 14. Walls, partitions and floor/ceiling assemblies separating dwelling units must have a sound transmission class of no less than ___ if field tested . A. B. C. D. 45 50 55 60 Keywords - Separating dwelling units, sound transmission This is more of a global question, think IBC. From the index, Chapter 12 is Interior Environment Section 1207 is Sound Transmission From Section 1207.2 Equipment and Systems you see the answer is A. The answer is located on Page 273 of the IBC. Fire protection mechanical IRC 1. Sprinklers shall have a temperature rating of not less than ___ degrees Fahrenheit . A. B. C. D. 120 135 150 165 IRC 1. Sprinklers shall have a temperature rating of not less than ___ degrees Fahrenheit . A. B. C. D. 120 135 150 165 Keywords - Sprinklers, temp rating From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.2 is Sprinklers, and from Section P2904.2.1 you see the answer is B. The answer is located on Page 609 of the IRC. IRC 2. The area of coverage of a single sprinkler shall not exceed ___ feet. A. B. C. D. 200 300 400 500 IRC 2. The area of coverage of a single sprinkler shall not exceed ___ feet. A. B. C. D. 200 300 400 500 Keywords - Sprinklers, coverage From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.2 is Sprinklers, and from Section P2904.2.4.1 you see the answer is C. The answer is located on Page 610 of the IRC. IRC 3. Painting of sprinklers is prohibited . A. TRUE B. FALSE IRC 3. Painting of sprinklers is prohibited . A. TRUE B. FALSE Keywords - Sprinklers, painting From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.2 is Sprinklers, and from Section P2904.2.6 you see the answer is A. The answer is located on Page 609 of the IRC. IRC 4. For a one story dwelling unit, the sprinklers must provide the designed flow rate for ___ minutes . A. B. C. D. 5 6 7 8 IRC 4. For a one story dwelling unit, the sprinklers must provide the designed flow rate for ___ minutes . A. B. C. D. 5 6 7 8 Keywords - Sprinklers, one story From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.5 is Water Supply, and from Section P2904.5.2 you see the answer is C. The answer is located on Page 611 of the IRC. IRC 5. The required flow rate for each sprinkler shall be based on all of the following except. A. B. C. D. Type of room Area Ceiling Configuration Temperature Rating IRC 5. The required flow rate for each sprinkler shall be based on all of the following except. A. B. C. D. Type of room Area Ceiling Configuration Temperature Rating Keywords - Sprinklers, flow rate From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.4 is System Design Flow, and from Section P2904.4.1 you see the answer is A. The answer is located on Page 611 of the IRC. IRC 6. CPVC and PEX are nonmetallic piping and tubing listed for use in residential dwellings sprinklers . A. TRUE B. FALSE IRC 6. CPVC and PEX are nonmetallic piping and tubing listed for use in residential dwellings sprinklers . A. TRUE B. FALSE Keywords - CPVC, PEX, residential From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.3 is Sprinkler Piping System, and from Section P2904.3.1 you see the answer is A. The answer is located on Page 610 of the IRC. IRC 7. In the available pressure equation, PLm is. A. Pressure Loss in the water service pipe B. Pressure loss in devices C. Pressure loss in the water meter D. Pressure loss in elevation IRC 7. In the available pressure equation, PLm is. A. Pressure Loss in the water service pipe B. Pressure loss in devices C. Pressure loss in the water meter D. Pressure loss in elevation Keywords - Pressure equation From the index, Chapter 29 is Water Supply and Distribution Section P2904 is Fire Sprinkler Systems Section P2904.6 is Pipe Sizing, and from Section P2904.6.2.1 you see the answer is C. The answer is located on Page 611 of the IRC. IBC 8. An automatic sprinkler system shall be provided in areas containing woodworking operations exceeding ___ feet . A. B. C. D. 1,500 2,500 3,000 3,500 IBC 8. An automatic sprinkler system shall be provided in areas containing woodworking operations exceeding ___ feet . A. B. C. D. 1,500 2,500 3,000 3,500 Keywords - Sprinkler system, woodworking This is more of a global question, think IBC. From the index, Chapter 9 is Fire Protection Systems Section 903 is Automatic Fire Sprinkler Systems Section 903.2 is Where required, and from Section 903.2.4.1 you see the answer is B. The answer is located on Page 185 of the IBC. IBC 9. An automatic sprinkler system shall be provided in a building with a Group M occupancy exceeding ___ feet . A. B. C. D. 10,000 11,000 12,000 13,000 IBC 9. An automatic sprinkler system shall be provided in a building with a Group M occupancy exceeding ___ feet . A. B. C. D. 10,000 11,000 12,000 13,000 Keywords - Sprinkler system, Group M This is more of a global question, think IBC. From the index, Chapter 9 is Fire Protection Systems Section 903 is Automatic Fire Sprinkler Systems Section 903.2 is Where required, and from Section 903.2.7 you see the answer is C. The answer is located on Page 185 of the IBC. IBC 10. An automatic sprinkler system must be supplied in a Group A-4 occupancy when the occupant load exceeds ___ people . A. B. C. D. 200 300 400 500 IBC 10. An automatic sprinkler system must be supplied in a Group A-4 occupancy when the occupant load exceeds ___ people . A. B. C. D. 200 300 400 500 Keywords - Sprinkler system, Group A-4 This is more of a global question, think IBC. From the index, Chapter 9 is Fire Protection Systems Section 903 is Automatic Fire Sprinkler Systems Section 903.2 is Where required, and from Section 903.2.1.4 you see the answer is B. The answer is located on Page 184 of the IBC. IBC 11. A repair garage smaller than 10,000 square feet must have an automatic sprinkler system. A. TRUE B. FALSE IBC 11. A repair garage smaller than 10,000 square feet must have an automatic sprinkler system. A. TRUE B. FALSE Keywords - Sprinkler system, repair garage This is more of a global question, think IBC. From the index, Chapter 9 is Fire Protection Systems Section 903 is Automatic Fire Sprinkler Systems Section 903.2 is Where required, and from Section 903.2.9.1 you see the answer is B. The answer is located on Page 185 of the IBC. Safety IBC 15. If the height of construction is 8 feet and the construction is taking place less than 5 feet from the lot line, construction railings are required. A. TRUE B. FALSE IBC 15. If the height of construction is 8 feet and the construction is taking place less than 5 feet from the lot line, construction railings are required. A. TRUE B. FALSE Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Table 3306.1, the Answer is A. The answer is located on Page 568 of the IBC. IBC 16. Covered walkways shall have a minimum clear height of ___ feet. A. B. C. D. 6 7 8 10 IBC 16. Covered walkways shall have a minimum clear height of ___ feet. A. B. C. D. 6 7 8 10 Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3306.7, the Answer is C. The answer is located on Page 568 of the IBC. IBC 17. A fire extinguisher must be located in every storage and construction shed. A. TRUE B. FALSE IBC 17. A fire extinguisher must be located in every storage and construction shed. A. TRUE B. FALSE Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3309.1, the Answer is A. The answer is located on Page 569 of the IBC. IBC 18. Construction railings shall be at least ___ inches high. A. B. C. D. 32 36 42 48 IBC 18. Construction railings shall be at least ___ inches high. A. B. C. D. 32 36 42 48 Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3306.4, the Answer is C. The answer is located on Page 568 of the IBC. IBC 19. What is the maximum cut slope for permanent excavations? A. B. C. D. 1 to 1 2 to 1 3 to 1 4 to 1 IBC 19. What is the maximum cut slope for permanent excavations? A. B. C. D. 1 to 1 2 to 1 3 to 1 4 to 1 Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3304.1.1, the Answer is B. The answer is located on Page 567 of the IBC. IBC 20. Sanitary facilities must be provided during construction and remodeling, but not for demolition. A. TRUE B. FALSE IBC 20. Sanitary facilities must be provided during construction and remodeling, but not for demolition. A. TRUE B. FALSE Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3305.1, the Answer is B. The answer is located on Page 567 of the IBC. IBC 21. Construction barriers for excavations less than 5 feet from the lot line must be at least ___ feet high. A. B. C. D. 4 5 6 8 IBC 21. Construction barriers for excavations less than 5 feet from the lot line must be at least ___ feet high. A. B. C. D. 4 5 6 8 Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3306.9, the Answer is B. The answer is located on Page 569 of the IBC. IBC 22. Stumps and roots must be removed to a depth of ___ inches below the surface of the ground in the area occupied by the building. A. B. C. D. 6 12 18 24 IBC 22. Stumps and roots must be removed to a depth of ___ inches below the surface of the ground in the area occupied by the building. A. B. C. D. 6 12 18 24 Keywords - Safety Related Question From the IBC index, Section Chapter 33 is Safeguards during Construction From Section 3304.1, the Answer is B. The answer is located on Page 567 of the IBC.