ME 391 Instrumentation LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel Performed: 03/05/2004 Soma: I believe I performed 50% of this lab. (Participation: __/50) Sinan Ozcan: I believe I performed 50% of this lab. (Participation: __/50) Abstract • The volumetric flow rate and centerline speed of air in a tube wind tunnel were measured for a range of blower speeds. As a consistency check, the centerline speed for each flow rate was compared to the centerlines speed based on slug and parabolic velocity profiles. • The volume flow rate and centerline speed were determined by measuring the pressure from a venturi tube and a Pitot probe using pressure transmitters. • The maximum volume flow rate was 0.077 + 0.002 m3/s. • The measured centerline speed was bracketed by the values predicted for slug and parabolic velocity for all blower speeds. Table 1 Atmospheric Pressure and Temperature Readings Tatm Patm [°C] [hPa] 23 860 Dpipe [inch] 2.067 Dtube Apipe Atube [inch] [m2] [m2] 2.25 0.002165 0.002565 K [1] 0.381 W40-inch W4-inch [Pa] 2.5 [Pa] 0.25 • This table presents the atmospheric temperature and pressure during the experiment. • It also presents the pipe and tube inner diameters and areas, and the flow coefficient for the venturi tube. • The manufacture stated uncertainties of the pressure transmitters are also included. Table 2 Measurement Readings and Calculated Values Flow Condition Blower Off 1 Fully Open 2 3 4 5 6 7 Fully Closed Pressure Uncertainty IV [mA] 4 11.08 10.88 10.36 9.82 9.45 8.98 4.16 PV [Pa] 0.0 4410.4 4285.8 3961.9 3625.5 3395.0 3102.2 99.7 2.5 IP [mA] 4 20.90 20.40 19.57 18.28 17.73 16.12 4.22 PP [Pa] 0.00 1052.76 1021.61 969.91 889.55 855.29 755.00 13.70 0.25 IG [mA] 4 5.7 5.7 5.5 5.4 5.4 5.2 4.1 PG [Pa] 0.0 1065.2 1034.1 959.3 897.0 841.0 766.2 87.2 P [kPa] 86 85 85 85 85 85 85 86 3 [kg/m ] 1.012 1.000 1.000 1.001 1.002 1.002 1.003 1.011 Q WQ S WS 3 3 [m/s] 0.000 45.891 45.198 44.020 42.142 41.309 38.794 5.206 [m/s] 0.054 0.055 0.057 0.059 0.060 0.064 0.475 [m /s] 0.0000 0.0775 0.0764 0.0734 0.0702 0.0679 0.0649 0.0116 [m /s] 0.0016 0.0015 0.0015 0.0014 0.0014 0.0013 0.0015 2.5 • This table presents the transmitter current and pressure differences for the venturi tube, Pitot probe and gage pressure for different flow conditions. The uncertainty of the pressures is also included. • The calculated tube absolute pressure, density, volume flow rate and centerline speed are also presented. • The uncertainty of the volume flow rate and speed are based on the uncertainties of the venturi tube flow coefficient and pressure measurements. Figure 1 Measured and Predicted Centerline Velocities Versus Volume Flow Rate 70 Centerline Speed, S [m/s] 60 50 Laminar Flow 40 30 20 Slug Flow 10 0 0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 Volume Flow Rate, Q [m3/s] • The measured centerline velocity is between the values predicted for slug and parabolic velocity.