DIGI SM-120 SETUP NOTES GOALS: UPDATE THE EPROM LOAD @LABEL SET FLAGS SET IP ADDRESS CREATING PLU’S AND LABEL FORMAT USING PYROBATCH TO BACK UP SETTING/UPDATING THE EPROM ON A SM-120 HOLD PRESET KEY 22 (OR THE LETTER L) HOLD REZERO THEN PRESS THE ON BUTTON OPTION ETHERNET OR RS232C APPEARS ON THE SCALE SCREEN PRESS 1 TO SELECT ETHERNET THIS SETS THE IP ADDRESS TO 10.10.10.1 NOW ON THE LAPTOP TURN OFF THE WIFI OPEN NETWORK AND SHARING CENTRE CHANGE ADAPTER SETTINGS BY RIGHT CLICKING ON ‘ETHERNET’ THEN ‘PROPERTIES’ HIGHLIGHT THE TCPIP4 OPTION AT THE BOTTOM THEN CLICK ‘PROPERTIES’ CHANGE THE IP ADDRESS TO 10.10.10.20 AND ALSO THE SUBNET MASK TO 255.255.255.0 CLICK OK AND CLOSE NOW TO FIND THE FILES TO UPDATE THE EPROM (TO VERSION 1.0.5) ON THE DESIGNATED LAPTOP THEY CAN BE FOUND IN THE TOP RIGHT CORNER IN THE FOLDER CALLED ‘NEW EPROM FILES (4) NOW RUN THE MINI PROGRAMMER V5, ALSO LOCATED ON THE RIGHT SIDE OF THE DESKTOP (TO SETUP CLICK SETUP FILE, CLICK ON COMP IMAGE, CLICK MINI PROGRAMMER FROM THE LIST AND SAY YES TO ALL OF THE OPTIONS) OPEN THE MINI PROGRAMMER SELECT SM-120 CLICK FILE LOAD FILE TO THE PROGRAM BUFFER POINT THE FILES AT (*BIN) SELECT NO.1 CLICK FLASH > PROGRAM > RUN IT SHOULD SAY ON THE SCALE ‘SCALE UPGRADE IS OK’ CLICK FILE > THEN ‘CLEAR BUFFER’ NOW POINT FILES AT (*TXB) FILES SELECT NO.2 TURN THE SCALE OFF AND ON AGAIN NOW ON THE SCALE PRESS AND HOLD REZERO AND THE PRESS KEY 22 (OR THE LETTER ‘L’) AS YOU TURN IT BACK ON SELECT ETHERNET NOW TO SEND THE NEXT ONE DOWN PRESS FILE > CLEAR BUFFER NEXT LOAD IN THE (*BAP) FILE (3) TURN THE SCALE OFF AND ON AGAIN NOW ON THE SCALE PRESS AND HOLD REZERO AND THE PRESS KEY 22 (OR THE LETTER ‘L’) AS YOU TURN IT BACK ON SELECT ETHERNET NOW TO SEND THE NEXT ONE DOWN FLASH > PROGRAM > RUN FINALLY LOAD THE (*HEY) FILE (4) FAST MODE IS OK FLASH > PROGRAM > RUN TURN SCALE OFF THEN BACK ON IT SHOULD NOW SAY THE NEWEST VERSION ON THE SCREEN (v.1.0.5) LOADING @LABEL THE LATEST VERSION IS V.27.1.1] RIGHT CLICK ON THE PROGRAM RUN AS ADMINISTRATOR INSTALL FINISH THE NEXT STEP IS TO SET THE IP ADDRESS ON THE SCALE (AND A COUPLE OF FLAGS) GO TO ‘Z’ MODE HOLD REZERO KEY AND TYPE 141 AT THIS POINT YOU SHOULD SEE SPOOO TO START TYPE 49 X 2 PRESS PRINT KEY TYPE 50 X 1 PRESS PRINT KEY TYPE 135 X 11 (OR WHATEVER THE LAST DIGITS ARE OF THE IP ADDRESS YOU HAVE SET) NOW PRESS PLU (THIS SAVES YOUR CHANGES) TURN SCALE ON AND OFF AGAIN TOGGLE BACK THROUGH TO Z MODE TYPE REZERO 0416 TYPE 192.168.001 – YOU HAVE ALREADY SET THE FINAL DIGITS IN THE PREVIOUS STEP (011) PRESS PLU BUTTON (THIS SAVES IT) TURN OFF SCALE & TURN ON AGAIN GO TO Z MODE AND CHECK THAT THE FULL IP ADDRESS HAS BEEN SET CORRECTLY BY TYPING REZERO 0416 AND CHECK THAT IT SAYS 192.168.001.011 NOW BACK TO THE COMPUTER CONFIRM THAT THE WIFI IS OFF OPEN NETWORK AND SHARING CENTRE CLICK ON ETHERNET SELECT TCPIP 4 PROERTIES SET IP TO 192.168.001.015 (MAKE SURE THE FINAL THREE DIGITS ARE DIFFERENT TO WHAT YOU HAVE SET ON THE SCALE) CLOSE ALL PROGRAMS NOW DO A PING TEST SEARCH FOR ‘CMD’ IN WINDOWS ON THE BLACK DOS SCREEN TYPE ‘PING 192.168.1.11 (IT IS IMPORTANT TO NOTE THAT HERE YOU HAVE TO REMOVE ANY ZEROS OR IT WILL NOT WORK) IT THE COMPUTER IS SUCCESSFULLY TALKING WITH THE SCALE THEN IT SHOULD SAY ‘REPLY ETC...’ FOR THE NEXT TEST TYPE ‘FTP 192.168.1.11’ IT SHOULD RESPOND BY SAYING ‘CONNECTED. WELCOME TO SM120’ PRESS ENTER THEN TYPE ‘BY’ AND CLOSE THE WINDOW USE PYROBATCH TO BACKUP/SEND DOWN FILES INSTALL PYROBATCH RIGHT CLICK ON THE PROGRAM AND CLICK ‘RUN AS ADMINISTRATOR’ INSTALL FOR THE FIRST TIME CLICK NEXT CLICK ACCEPT DROP THE ‘UPLOAD’ FOLDER ONTO THE C: COPY THE ‘SCRIPTS’ FOLDER INTO DOCUMENTS AND REPLACE WHATEVER IS IN THERE (IF ANYTHING) NOW OPEN PYROBATCH CLICK EDIT > THEN OTHER > THEN ‘START WITH DOWNLOADS’ CHANGE THE IP ADDRESS TO THE SCALE (IN THIS CASE IT’S 192.168.1.11) CLICK FILE > SAVE DO THE SAME WITH UPLOADS CLICK FILE > SAVE CLICK ‘EXECUTE’ DROP DOWN MENU THEN CLICK DOWNLOAD (THIS SENDS FILES DOWN TO THE SCALE / THE WHOLE PROGRAM) *EVEN THOUGH THE PREVIOUS STEP IS CALLED DOWNLOAD YOU ARE UPLOADING THE INFORMATION TO THE SCALE ON THE SCALE NO GO TO Z MODE AND PRESS REZERO 1439 THEN PRESS PRINT RUNNING @LABEL CLICK ON THE @LABEL LINK SELECT YOUR COUNTRY > UK > SUBMIT LOGIN WITH USERNAME (ADMIN) AND PASSWORD (TERAOKA) IN @LABEL CLICK ON ‘SCALE’ CLICK ON ‘SCALE LIST’ CLICK ON ‘CREATE’ AT THE BOTTOM SCALE CODE = 123 SCALE IP = 192.168.1.11 (THE FINAL DIGITS YOU HAVE SET PREVIOUSLY) SCALE TYPE = SM120 SCALE STATUS = WORK NORMAL RELATED GROUP = 997 DEFAULT IF WORKED CORRECTLY THEN A MESSAGE SHOULD APPEAR SAYING ‘CREATE SUCCESS’ COPY BACKUP FILE ‘jdstore_20150508’ C: > JDIGIDTORE > DBBACKUP > PASTE IT IN HERE TOOLS > DATABASE CLICK ON THE FILE THAT YOU HAVE JUST DROPPED IN CLICK RESTORE THE PROGRAM WILL NOW SAY PROCESSING, LOOK AT YOUR WATCH AND RESTART THE COMPUTER AFTER ROUGHLY 5 MINS GO INTO SCALE LIST EDIT SCALE IP ADDRESS TO WHAT YOU SET IT TO + DELETE THE SERIAL NUMBER NOW CLICK RESTART SETTING UP A PLU CLICK PLU LIST > THEN CREATE TYPE IN NAME AND PRICE OVERRIDE – NO MAINGROUP – 997 UNIT TYPE – WEIGHT OR NON TAX – IGNORE 1ST LINE – ADD PLU NAME CHARACTER – M3 (THIS SIZE IS USUALLY ABOUT RIGHT) BARCODE (IF NEEDED) EAN SELECT BARCODE FORMAT: FF CCCC XCD XXXXX CD (13) ITEM CODE – 1 BARCODE FORMAT FLAG 1 – 0 BARCODE FORMAT FLAG 2 – 2 BARCODE FORMAT X SPEC – TOTAL PRICE STILL ON THAT PLU, CLICK LABEL AT THE BOTTOM SCROLL THROUGH THE LIST TO THE BOTTOM AND SET LABEL FORMAT 1 AS ‘F1 CUSTOM’ CLICK ON ‘SEND’ INGREDIENTS SELECT YOUR PLU CHARACTER M1 < THIS IS A GOOD SIZE FOR THE INGREDIENTS SPECIAL MESSAGE < ENTER IF NEEDED FLEXIBLE NUTRITION < ENTER DATA + ADD A SECOND LABEL FORMAT IF NEEDED EDIT DISCOUNT