Idaho Microfabrication Laboratory IML SAFETY TRAINING ET105, ET107, ET108A & ET106A Peter Miranda Director, Idaho Microfabrication Laboratory Revision D 8/11/11 1 Idaho Microfabrication Laboratory Topics Lab Etiquette General Equipment Information General Lab Safety Rules Gowning Procedures Hazardous Chemicals Hazardous Gases Accidental Chemical Spill Containment Cleanroom Access IML Website Emergency Contacts Revision D 8/11/11 2 Idaho Microfabrication Laboratory ET107 (cleanroom) & ET105 Layout Class 1000 clean room - < 1000 particles greater than 0.5µm in size for a given cubic foot of air. in/out from ET105 Revision D 8/11/11 3 Idaho Microfabrication Laboratory Cleanroom Equipment Capabilities Materials Science Research Scanning Electron Microscopes (SEM) & (FESEM) • Electron Backscatter Defraction (EBSD) • Energy Dispersive Spectroscopy (EDS) Integrated Circuit Fabrication Oxide/Diffusion Furnace Photolithography • Spin coater • Contact aligner • Thermal Ovens Wet bench processing Thin Film Deposition Thermal Evaporator Magnetron Sputtering Revision D 8/11/11 Thin Film metrology Ellipsometer Nanospec Four point probe Optical profilometry Dry Etch DRIE etcher Asher Ion Mill CMP Wire Bonder Rapid Thermal Processor Various high powered microscopes 4 Idaho Microfabrication Laboratory Cleanroom Gowning Procedures Cleanroom bunnysuits are intended to keep the cleanroom clean, not the wearer safe. They do provide an extra layer of protection that may protect against minor spills and splashes, however, when using dangerous materials, a plastic or rubber apron should be used. Do not enter gowning room with dirty shoes ie. mud, sand, etc. (use shoe covers located outside of cleanroom if needed. Put on hood (all facial hair must be covered with hood, mask, etc.) Put on bunny suit Put on shoe covers Put on gloves, safety glasses • Blue (Nitrile) gloves are used ONLY for non-chemical operations o o • Yellow (Latex) gloves are to be used for all chemical operations. o o o Typical uses include working on vacuum systems, protecting substrates from contamination, operating microscopes, operating equipment. Because these gloves don't get contaminated with chemicals, you are permitted to operated door handles and lab equipment with these gloves. Latex gloves do NOT protect against all chemicals so additional gloves might need to be worn over the latex gloves for protection. Typical chemical operations are mixing acid solutions (except HF), using KOH, using etchants, using organic solvents or chemicals, etc. NEVER operate door handles or equipment while wearing yellow gloves. Residual chemicals on the gloves can contaminate surfaces and cause serious injury to future users. Sign-in to cleanroom logbook Place single-use gowning gear in hamper, if you are a frequent user of the IML, you can hang up your gear for the next time. A storage rack is located in the 5 Revision D clean gowning are to enable limited (10 uses, or until shoe covers show particles) 8/11/11 re-use for economic reasons. Idaho Microfabrication Laboratory General Cleanroom Etiquette Rules and Guidelines for Personal Lab Behavior Drinking, eating and gum-chewing are not allowed in any part of the lab. Full cleanroom attire must always be worn while in the cleanroom. Be discrete in coughing, sneezing, or blowing your nose. At the very least, turn away from the processing area and change your gloves before commencing processing. Minimize the amount of materials stored in the lab. All personal items must be labeled with your full name, and contact phone number. Acceptable Materials in the Cleanroom Cleanroom notebooks and cleanroom paper Wafers and tweezers (put away when not in use). Pens (preferably ball-point). Materials with smooth, hard surfaces which can be cleaned with alcohol wipes. The following materials are not considered cleanroom-compatible: Wood pulp-based paper products, which includes regular paper, tissues, cardboard, books, and magazines. Styrofoam products. Any powders. Erasers, pencils, felt-tipped pens (other than Sharpie markers). Anything that can easily shred or aerosolizes; i.e., anything that may serve as a source of particles. 6 Revision D 8/11/11 Idaho Microfabrication Laboratory General Cleanroom Safety Rules No open toed shoes in ET105 or ET107. No shorts or skirts allowed in cleanroom. No loose long hair (hair must be Exits pulled back in a pony tail) Know your safety exits. Know where the eye wash stations are. Know where the fire extinguishers are located. Report any safety concerns to the IML director. Revision D 8/11/11 7 Idaho Microfabrication Laboratory General Cleanroom Safety Rules Never work alone in cleanroom when working with hazardous chemicals. Use the “buddy” system. Unlabeled chemicals are significant environmental and health hazards. When you make up a solution, remember to label it. When labeling a solution, you should include the following: Name of the material contained Primary hazard of the material Person responsible for the material Date of filling or preparation If your name, the substance, and a date are not present on any chemicals left out on the counters (specifically those in glassware), the chemicals will be disposed of. If any chemicals need to be left out on the counters for longer than 48 hours, the label should include the date prepared and the date the solution will be cleaned up. Be courteous and clean up you own chemicals in reasonable time frames. Leaving the lab Clean up after yourself. Leave stations neat and ready for the next person to use. Remove personal items from general-use areas after you are done processing. Label your work. Any materials you plan on taking out of the lab with you should be bagged to prevent contamination. In the gowning room: remove your bunnysuit from the bottom up: Revision D 8/11/11 • • Booties - Put booties in the appropriate bin. Suit - Keep the sleeves, main body, and as much of the suit as possible off the floor. 8 Idaho Microfabrication Laboratory GENERAL EQUIPMENT SAFETY Revision D 8/11/11 9 Idaho Microfabrication Laboratory General Equipment Safety Dangerous Light Sources: Plasma, Ultraviolet lamps Thermal Evaporator Moving parts - pinch points Dry Etch Clean up area when you are done. Never leave unlabeled chemicals laying around. Wear chemical apron, face shield, gloves in addition to bunnysuit. SEM Smocks, gloves, face mask, eyewear. Wipe down all working surfaces when your done working on tool. Wet Bench Processing – Hazardous chemicals! UV Source on Mask Aligners, Pattern Generators Light from an Ar plasma in sputter deposition and ion etch tools Cryo-tank, RF power CMP Revision D 8/11/11 Smock, gloves, eyewear Moving parts – pinch points 10 Idaho Microfabrication Laboratory CLEANROOM CHEMISTRY 101 Revision D 8/11/11 11 Idaho Microfabrication Laboratory General Cleanroom Chemical Safety Always review the MSDS sheets prior to using chemicals. Always wear PPE when working with chemicals. Always have a “buddy” present with working with hazardous chemicals. Never have more than one chemical out at a time on the wet bench. Never remove chemicals from the cleanroom. Never leave chemicals or chemistries out on the wet bench for extended periods of time. Always clean up your area when you are done using chemicals. Revision D 8/11/11 12 Idaho Microfabrication Laboratory Personal Protective Equipment (PPE) Personal Protective Equipment Personal Protective Equipment (PPE) is not required just because it makes you look GOOFY. It is there to give you added protection against any accidents that may occur while working in the lab. PPE is to be worn in addition to your bunny suit if you are working with chemicals. There are several different types of PPE but you should always wear what is appropriate for your task. Safety Glasses or Chemical Goggles Lab Coat or chemical apron Gloves Safety Glasses and Chemical Goggles Safety glasses and chemical goggles are not the same thing! Safety glasses protect your eyes from any type of flying debris. Chemical goggles can protect your eyes from flying debris. They also keep vapors, dust, and splashed chemicals from getting into your eyes. Revision D 8/11/11 13 Idaho Microfabrication Laboratory General Cleanroom Chemical Safety (Glassware) Prevent damage to glassware during handling and storage. Inspect glassware before and after each use. Discard any cracked, broken, or damaged glassware. Thoroughly clean and decontaminate glassware after each use. NEVER put HF acid into glassware (use plastic beakers!) Guidelines for disposing of broken glass: Do not pick up broken glass with bare or unprotected hands. Use a brush and dust pan to clean up broken glass. Remove broken glass in sinks by using tongs for large pieces and cotton held by tongs for small pieces and slivers. Place all the recovered broken glass into the “sharps” container. Revision D 8/11/11 14 Idaho Microfabrication Laboratory HAZARDOUS CHEMICALS Revision D 8/11/11 15 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Acids pH <7 Are typically soluble in water. Are corrosive. Form salts when mixed with bases. Turn litmus paper red. Litmus paper located above wet bench and inside toolbox. Burn organic tissues and/or inorganic materials. Revision D 8/11/11 16 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Acids Acetic - CH3COOH Liquid and vapors cause severe burns to skin. Reacts vigorously with oxidizing agents and other acids (particularly nitric). Odor similar to that of strong vinegar. Incompatible with most other acids. Store alone! Chromic - H2CRO4 Liquid and vapors cause severe burns to skin. Corrosive to nasal passages. Contains a suspected carcinogen. Hydrochloric - HCL Highly corrosive to skin and mucous membranes. Repeated exposure causes erosion of teeth. Hydrofluoric - HF Liquid and vapors cause burns that may not be immediately painful or visible. HF attacks glass. HF looks like water and can kill in small amounts. Found in Buffered Oxide Etch (BOE). Use only in plastic containers. Nitric - HNO3 Highly corrosive to skin, mucous membranes and teeth. Highly reactive with acetic acid. Reacts explosively with combustible organic or other oxidizers. Use only in glass containers. Phosphoric - H3PO4 Liquid is highly irritating to skin. Vapors are highly toxic. Contact with most metals causes formation of flammable and explosive hydrogen gas. Sulfuric - H2SO4 Liquid and vapors are extremely corrosive to skin and mucous membranes. Generates heat upon contact with water. Reacts with acetic acid. Keep away from water. Citric - C6H8O7 Revision D 8/11/11 Skin and eye irritation 17 Idaho Microfabrication Laboratory Special Precaution on HF Hydrofluoric Acid Hydrofluoric acid (HF) is EXTREMELY dangerous. Be extra attentive when working with HF. HF is colorless and odorless; it looks and smells like water. HF is an ingredient in many oxide etches which are used to etch glass. Because of the danger, only trained personnel should pour HF. According to DuPont’s MSDS. HF will: • • • HF may: • • • Kill if more than 5% of the body is exposed. Kill if ingested or inhaled. Depending on concentration, not cause pain for up to 24 hours after contact. Some of the symptoms of HF exposure are: • • • • Penetrate skin. Attack (decalcify) bones. React with your body’s chemicals to make poisonous salts. Itching. Red or white discoloration of the skin. Pain within 24 hours after contact. Discoloration under fingernails or toenails. Treatment with Calcium Gluconate Gel Revision D 8/11/11 Calcium gluconate gel is a topical antidote for HF skin exposure. Calcium gluconate works by combining with HF to form insoluble calcium fluoride, thus preventing the extraction of calcium from tissues and bones. Keep calcium gluconate gel nearby whenever you’re working with HF. Calcium gluconate can be ordered through Life Safety Associates www.lifesafety.com. Calcium gluconate has a limited shelf life and should be stored in a refrigerator if possible and replaced with a fresh supply after its expiration date has passed. Use disposable gloves to apply calcium gluconate gel. Even after applying calcium gluconate, it is essential that a medical evaluation be made. 18 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Acid chemistry – Waste Disposal Acid chemistry (including piranha), must be aspirated from their containers. An aspirator has a Teflon® tube through which it sucks a liquid from a container. Our Microfab wet sink has an aspirator. The fresh water plenum flush is automatically activated when an aspirator is turned on. The plenum flush adds water to aspirated waste, further diluting it. NEVER POUR ACIDS, BASES directly down a drain: Always use the aspirator. Never mix solvents with acids when aspirating – This is a potentially explosive combination! And remember AAA-Always Add Acid to water! 19 Revision D 8/11/11 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Bases pH > 7 Are typically water soluble. Are slippery. Form salts when mixed with acids. Turn litmus paper blue. Are corrosive. Burn organic tissues. Revision D 8/11/11 20 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Bases Ammonium Hydroxide - NH4OH Irritating to skin and mucous membranes. Emits highly toxic vapors when heated. Potassium Hydroxide - KOH Sodium Hydroxide – NaOH Photoresist developers Revision D 8/11/11 21 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Bases – Waste Disposal Aspirate chemical waste same as acids. Revision D 8/11/11 22 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Solvents A solvent is a chemical substance which dissolves another substance. The most common solvent is water. Solvents are used extensively in the electronics industry. Compounds such as Isopropyl Alcohol (IPA) and acetone are used to clean and dry wafers, glassware, equipment, and most working surfaces in the lab. In addition, solvents are the principle components of many process chemicals such as photoresist. Organic solvents react chemically with acids, producing a violent reaction. As a byproduct of the chemical reaction, gases are released, as well as a great amount of heat. Therefore, acids and solvents and their vapors should never come into contact with one another. Organic solvents should never come in contact with oxidizers such as hydrogen peroxide and chromic etch. Oxidizers are a class of their own and will also react violently with organic solvents and acids. Major solvents and their abbreviations used in the IML: Acetone - ACE Isopropyl Alcohol - IPA Propylene Glycol Monomethyl Ether Acetate - PGMEA Revision D 8/11/11 23 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Solvents Acetone-ACE Irritates eyes, nose and throat; headaches; skin dryness Isopropyl Alcohol-IPA Dries skin; irritates eyes, nose and throat; drowsiness Methanol Ethyl Lactate-Positive Photo Resist Combustible liquid; skin, eye, respiratory irritant; nervous system toxin Revision D 8/11/11 24 Idaho Microfabrication Laboratory Cleanroom Hazardous Chemicals Solvents – Waste Disposal Organic solvents such as chlorobenzene or TCA (trichloroethane) and photoresist, should never be aspirated or poured down the drain. Solvents must be poured into solvent disposal bottles. Never pour acid for disposal into a solvent waster bottle because a violent reaction may result. Make sure chemical disposal bottles are not overfilled. When a chemical disposal bottle is approximately 75% full: Loosely cap the bottle. DO NOT TIGHTEN THE CAP. This prevents accidental pressure buildup from breaking the bottle. Remove the label from the chemical disposal bottle. Enter the summary of contents to the peel-off label and place on the bottle. Chemicals for disposal placed in the Waste Chemical Cabinet must be labeled with contents and the name of the lab member. Placing unlabeled chemicals for disposal in this cabinet is a violation of lab policy, which may result in suspension from the Microfab. You must fill out the Chemical Disposal Manifest Sheet located on top of the disposal cabinet. The bottles are picked up by the BSU Environment, Health and Safety Department. Notify the Microfab office if the storage area is full. Use a safety carrier if the bottle is glass. Rinse bottles thoroughly 3 times under the fumehood. This will prevent exposure to volatile compounds while rinsing bottles. Wear a face shield and chemical resistant gloves while doing so. Once the bottle has been rinsed 3 times, black out the label with a marker. The scratched label indicates that the bottle has been properly rinsed. Collected in containers for pick up by Environmental Safety Services. Small incidental quantities should be rinsed down the drain with copious amounts of water. For questions about waste solvents, contact the lab manager. Do not dump solvents down the drains. It is very important to clean up solvent spills in order to minimize the fire hazard and the amount of vapors present in the lab. If you find a spill and can not identify it, contact the lab manager. The spilled chemical needs to be identified before it can be cleaned up. Revision D 8/11/11 25 Idaho Microfabrication Laboratory ACCIDENTAL SPILL CONTAINMENT Revision D 8/11/11 26 Idaho Microfabrication Laboratory Accidental Chemical Spill vs. Unknown Liquid Substance Small quantity of unknown liquid substance on floor or wet bench Treat all unknown liquid substances as an acid or base. NEVER ASSUME IT IS DI WATER! Test pH level with litmus paper and cleanup accordingly. Accidental Chemical Spill Small chemical spill (<4L) • • • Large chemical spill (>4L but less than 5gal) • • Clean up spill with chemical spill pillows or blankets. Spill pillows & blankets are designed to be very absorbent and neutralize acid spills. Dispose of waste in appropriate bin. Notify lab manager at once! Leave the lab. For VERY large chemical spills (very large puddle of unknown liquid on floor • • • Leave lab space immediately. Notify lab manager! Call 911. Use your best judgment; if the spill is going to put anyone else in the room and/or building in danger, act accordingly. Revision D 8/11/11 27 Idaho Microfabrication Laboratory Chemical Spill Clean-up (only for trained personnel) Small chemical spill Test spill pH with litmus paper if chemical is unknown before proceeding. Clean up spill with chemical spill pillows or blankets. • Spill pillows & blankets are designed to be very absorbent and neutralize acid spills. Dispose of waste in appropriate bin. Large chemical spill Notify lab manager at once! Use chemical spill containment kit if possible before leaving lab. Leave lab immediately. For VERY large chemical spills, pull emergency fire alarm on your way out the door. Use your best judgment; if the spill is going to put anyone else in the room and/or building in danger, act accordingly. Revision D 8/11/11 28 Idaho Microfabrication Laboratory HAZARDOUS GASES Revision D 8/11/11 29 Idaho Microfabrication Laboratory Cleanroom Hazardous Gases Cryogens Cylinders of both toxic and non-toxic compressed gases are in use throughout the lab. Only trained staff may handle any compressed gas cylinders. Gas cylinders must be chained and strapped down at all times. All liquid nitrogen containers must be approved by the Microfab staff. Precautions Revision D 8/11/11 The large volume of gas produced from evaporation of a liquid can displace sufficient oxygen in a closed room to be dangerous (nitrogen asphyxiation). Ensure you have adequate ventilation for any operation consuming or transferring liquid nitrogen or helium. Do not spill on the floor. Repeated spills will cause accelerated 30 mechanical damage to concrete, etc. Idaho Microfabrication Laboratory Cleanroom Hazardous Gases Compressed Gases Cylinders should be stored in appropriately ventilated closets or in an open storage area. Store gases according to chemical compatibility . Do not place gas cylinders such that there is contact with electrical circuitry. Never use cylinders that cannot be identified positively. Inspect cylinder valves for damage or corrosion prior to use. If unsuitable for use, return to supplier Never lubricate or modify the cylinder valves. Do not put oil or grease on the high pressure side of any oxygen, chlorine or other oxidizing agent cylinder valve. A 31 Revision Dfire or explosion can result. 8/11/11 Idaho Microfabrication Laboratory Cleanroom Hazardous Gases Compressed Gases Use toxic, flammable, corrosive, or reactive gases in fume hoods only. Post signs in the laboratory area when using any of these type gases. Never bleed cylinders completely empty. Leave a slightly positive pressure (30 psi) to keep contaminants out. (Never heat a compressed gas cylinder to "milk" out the last bit of gas. The base plug softens and it becomes a missile.) Remove the regulator from an empty cylinder and replace the protective cap. Mark the cylinder "empty" and place it in the appropriate location for pickup. Notify Microfab Staff. Never open a cylinder more than 1/2 to 3/4 of 1 turn. This way the cylinder can be turned off quickly in the event of an emergency. Review the MSDS sheets for the gasses that you are using. Many of the gasses are toxic. All high pressure gasses, regardless of toxicity, should be treated with respect. Before using any gas on any piece of equipment, verify that the gas that you think is connected is the one that actually is connected. Always wear safety glasses when handling compressed gases. Make sure all cylinders are properly labeled. Regulators, gauges, and hoses should not be interchanged among gases. Do not place any item on top of a cylinder that could damage a safety device or interfere with quick closing of a valve. Revision D 8/11/11 32 Idaho Microfabrication Laboratory CLEANROOM ACCESS Revision D 8/11/11 33 Idaho Microfabrication Laboratory Cleanroom Access Proximity card access only. Limited access through double doors between ET105 & ET107. Never leave doors propped open. Always report issues with the HVAC system (too hot or too cold) to IML Manager. Revision D 8/11/11 34 Idaho Microfabrication Laboratory Cleanroom Information Tools IML Website http://coen.boisestate.edu/IMFL/index.html designed to be used as a reference guide for cleanroom operations. • • • • • Safety procedures Equipment operating procedures General semiconductor processes Chemical inventory Cleanroom chemical data sheets IML Blackboard Website Revision D 8/11/11 Available to all cleanroom users. Contains all safety documents including the cleanroom Standard Operating Procedures (SOP) 35 Idaho Microfabrication Laboratory Emergency Response Contacts (in order of contact) Pete Miranda, Lab Manager x65713 or 447-6636 Paul Robertson, COEN Lab Coordinator, x65932 or 761-6824 Dick Sevier, COEN Safety Officer, x61022 or 286-8175 Jim Stevenson, COEN Staff Engineer, x65757 or 794-5809 Rex Oxford, interim COEN Facilities Manager, x65744 or 850-4490 Cal Gillis, BSU Environmental Health Officer, x63999 All MAJOR spills must be reported to the Boise Department of Public Works. Boise Department of Public Works Contact List • Walt Baumgartner, Senior Environmental Specialist 343-3991 • Mike Hunter, Pretreatment Program Director 384-3993 Revision D 8/11/11 36 Idaho Microfabrication Laboratory Questions Revision D 8/11/11 37 Idaho Microfabrication Laboratory Revision D 8/11/11 38