Capnography in the PACU: Theory and Clinical Applications of end tidal C02 Monitoring Perianesthesia Nurses Association of British Columbia Cathy Hanley, RN, BSN November 6, 2010 Objectives Review of physiology, ventilation vs oxygenation Identify normal and abnormal etC02 values and waveforms and appropriate clinical interventions Discuss current applications of capnography in the PACU and beyond Discuss current standards and recommendations Review of capnography case studies Brief History of Capnography Used in anesthesia since the 1970s Canadian Anesthesiologists’ Society requires it in the OR New recommendations and standards expanding utilization Capnography outside of the OR Capnography = Solutions for all Intubated and Non-Intubated patients Capnography can be used in all areas of the hospital PACU ICU OR EP/ Cath MedSurg Pain Mgmt Peds . MRI GI Overview of Capnography Capnography is the non-invasive, continuous measurement of CO2 concentration at the airway Capnography provides three important parameters: • Respiratory rate detected from the actual airflow • Numeric etCO2 value • Normal range 35-45 mmHg • Waveform tracing for every breath Obtaining an Accurate Respiratory Rate Manual Counting Impedance (ECG Leads) etCO2 • Measures: • Chest or air movement • Measures: • Attempt to breathe • Chest movement • Measures: • Actual exhaled breath at airway • Based on observation or auscultation that may be restricted by patient movement, draping or technique • Based on measuring respiratory effort or any other sufficient movement of the chest • Hypoventilation and No Breath detected immediately! • Most accurate RR, even when you are not in the room! Respiratory Cycle = Oxygenation and Ventilation Oxygenation • The process of getting O2 into the body Two separate physiologic processes • The process of eliminating CO2 from the body Ventilation • Measures etCO2 • Reflects ventilation • Hypoventilation & apnea detected immediately Pulse Oximetry Capnography Important Measurements http://www.covidien.com • Measures SpO2 • Reflects oxygenation • Values lag with hypoventilation & apnea, several to many minutes The Relationship between PaCO2 and etCO2 etCO2 normal range is 35 - 45 mmHg Under normal ventilation and perfusion conditions, the PaCO2 & etCO2 will be very close – 2 – 5 mmHg with normal physiology Ideally, every alveolus is involved in air exchange (ventilation) and has blood flowing past it (perfusion), but in reality, ventilation and perfusion are never fully matched, even in the normal lung Ventilation-Perfusion Mismatch There is inappropriate matching of ventilation and perfusion when: – “Dead space” is being ventilated with no perfusion • – Since no gas exchange occurs, air coming out is the same as air going in (no CO2) Unventilated areas of lung are being perfused (“Shunt”) • Effect on etCO2 may be small but oxygenation may decrease greatly Dead Space Ventilation Physiologic – Mechanical – conducting airways and unperfused alveoli breathing circuits Disease states leading to this include: – – – – Severe hypotension Pulmonary embolism Emphysema Bronchopulmonary dysplasia Ventilation-perfusion mismatch Bronchial intubation Increased secretions Mucus plugging Bronchospasm Atelectasis Summary - EtCO2 vs. PaCO2 End tidal CO2 (EtCO2) = noninvasive measurement of CO2 at the end of expiration EtCO2 allows trending of PaCO2 - a clinical estimate of the PaCO2, when ventilation and perfusion are appropriately matched Wide gradient is diagnostic of a ventilation-perfusion mismatch EtCO2 monitoring allows for a breath by breath assessment of ventilation. Why use etC02 in the PACU ? Accurately monitors effective ventilation, giving a true airway respiratory rate • Early warning of : Hypoventilation Apnea Obstruction Provides easy and accurate airway monitoring for intubated or non-intubated patients – Promotes better ventilation assessment resulting in timely interventions – Titrate sedation and pain medication Why use etC02 in the PACU? Indicator of Malignant Hyperthermia Use with patient with history of respiratory compromise, such as asthma or COPD to monitor trend and need for breathing treatments and response to treatment Endotracheal tube placement Monitoring during weaning Decrease frequency of arterial blood gases Use with non-invasive ventilation (NIV) Case Study: Microstream Capnography in the PACU: Submitted by: Larry Myers RRT Cottonwood Hospital Murray, Utah Profile A 31-year-old female s/p abdominal hysterectomy 6 months prior to admission is admitted with right lower quadrant pain. The patient underwent a bilateral salpingooophorectomy and lysis of adhesions on this admission. On post-op day one she became hypotensive and had a substantial decrease in her hematocrit. The patient was returned to the OR for an exploratory laparotomy. Case Study in PACU Clinical Situation: When the patient was returned to the PACU, she was extubated and became acutely hypoxic on a non-rebreather mask. The patient was in profound distress, drowsy, lethargic, but arousable and able to converse with c/o severe abdominal and chest pain. Sp02: 82% pH: 7.22 PaC02: 64.9mmHg HCO3: 25.5mEq/L Pa02: 53mmHg Sa02: 81% RR: 40bpm HR: 130bpm BP: 107/48 Clinical Situation At this point anesthesia was preparing to reintubate. A suggestion was made to use etC02 with an oral/nasal cannula and place the patient on a high flow 02 delivery system with an Fi02 of 1.0 and monitor the patient closely. The patient was rushed to the Radiology Department for a CT angiogram where a pulmonary embolus was ruled out. Initial values: etC02: 62mmHg Sp02: High 80’s Over the next 2 hours, etC02 fell to 44mmHg and Sp02 increased to 98%. Discussion The continuous monitoring of EtCO2 and SpO2 when measured in concert but evaluated independently allowed this patient to be safely observed and avoid reintubation and mechanical ventilation. It is also interesting to note, retrospectively, an expensive procedure to rule out PE may have been avoided with a better understanding of the relationship between arterial and end-tidal CO2. The probability of a PE in this case was low with a measured EtCO2 of 62 mmHg and a correlating PaCO2 of 64.9 mmHg. One would expect a wider gradient in the presence of significant dead space ventilation. PACU, Post-op PCA, Med/Surg Floors Post operative patients on Patient Controlled Analgesia (PCA) - often starts in PACU Bariatric Patients/Obstructive Sleep Apnea(OSA) high risk patients Awareness building regarding the need for monitoring ventilation/breathing on general floors – – Patient sentinel events/deaths Recent professional statements (APSF, ISMP) Great need for more education on Oxygenation vs. Ventilation for nurses in non-acute areas Compelling Recent Research “During analgesia and anesthesia, cases of respiratory depression were 28 times as likely to be detected if they were monitored by capnography as those that were not” University of Alabama – Birmingham, Waugh, Epps, Khodneva - meta-analysis presented at the Society of Technology in Anesthesia International Congress, January, 2008 Capnography monitoring in patients receiving patient controlled analgesia (PCA) Patient safety with Patient Controlled Analgesia (PCA) Patient Controlled Analgesia (PCA) aids patients in balancing effective pain control with sedation The risk of patient harm due to medication errors with PCA pumps is 3.5-times the risk of harm to a patient from any other type of medication administration error 2004 more deaths with PCA than with all other IV infusions combined Due to oversedation and respiratory depression with PCA delivery Sullivan M, Phillips MS, Schneider P. Patient-controlled analgesia pumps. USP Quality Review 2004;81:1-3. Available on the web at: http://www.usp.org/ pdf/patientSafety/qr812004-09-01.pdf. PCA Issues List PCA by proxy Drug product mix-ups Device design flaws Inadequate patient/family education Practice issues including pump misprogramming Inadequate monitoring ISMP Medication Safety Newsletter, July 10, 2003 Vol 8, no.14 Currently, no monitoring during PCA therapy at most hospitals Post operative surgical units where there is no centralized monitoring Large units making proximity to patient impossible Vital signs are typically every 4 hours Sometimes spot checking with pulse oximetry Nurse to patient ratio can be 1:6 – 1:10 How Ventilation Deteriorates when Administering Opioids Opioids Depress the Brain’s signals to the Respiratory Muscles CO2 Production CO2 Removal Case scenario 16 yr-old Billy falls off his skateboard and sustains a left femur fracture. He is now post-op from ORIF and is in the PACU extubated. He rates his pain at a 10 on 0-10 scale and has been given multiple doses of IV Morphine and is now on a PCA pump for pain. Case scenario Later that evening on the med-surg floor, after hours of poor pain control, Billy falls asleep Afraid Billy will soon wake up and again be in severe pain, Billy’s mother repeatedly presses his morphine PCA button while he is asleep He subsequently stops breathing and is resuscitated, but suffers hypoxic brain injury Obstructive Sleep Apnea Sleep apnea is the most widely known sleep disorder besides insomnia Believed to be under-reported 18-40 million people have sleep apnea – – Effects 2% of middle-aged females Effects 4% of middle-aged males More common in men It is estimated that nearly 80% of men and 93% of women with moderate to severe sleep apnea are Practice Guidelines for the Perioperative Management of Patients with Obstructive undiagnosed Sleep Apnea, Anesthesiology 2006; 104:1081–93 Sleep Diagnosis and Therapy ♦ Vol 3 No 5 September-October 2008 Mechanism of OSA…a vicious pattern Muscles of the pharynx relax during deep sleep Stimulates and arouses patient to ventilate Survival Mechanism Acidosis activates respiratory centers in the CNS Airway obstruction Hypoxemia & Hypercarbia A more vicious pattern…with sedation Muscles of the pharynx relax during deep sleep Does not ventilate Acidosis activates respiratory centers in the CNS Opiates & sedatives inhibit arousal mechanisms Airway obstruction Hypoxemia & Hypercarbia Respiratory Arrest Without Intervention PCA Case Scenario #2 60 year old female with morbid obesity and history of intractable low back pain X-rays demonstrated severe bone-onbone changes in both knee and hip areas Placed on PCA continuous infusion with PCA demand dose Placed on continuous SpO2 and EtCO2 monitoring PCA Case Scenario #2 cont. Soon after starting PCA, patient desaturated to SpO2 = 85% Patient placed on 60% O2 aerosol mask and EtCO2 monitoring discontinued PCA continuous discontinued, PCA demand dose continued PCA Case Study #2 cont. Following morning, patient appeared very lethargic and difficult to arouse SpO2 in high 90s EtCO2 monitor reapplied on patient with readings of 74 mmHg* indicating elevated CO2 level Patient was transferred to ICU with diagnosis of obstructive sleep apnea complicated by obesity and PCA Normal Waveform Anatomy of a Waveform D A-B: Baseline = no CO2 in breath, end of inhalation B-C: Rapid rise in CO2 C-D: Alveolar plateau D: End point of exhalation (EtCO2) D-E: Inhalation Abnormal waveforms – No Breath loss of waveform Sudden loss of waveform and EtCO2 to zero or near zero / no respiration detected – Possible causes • Intubated: Kinked or dislodged ETT Total airway obstruction • Complete disconnect from ventilator Non-intubated: Apnea Dislodged Capnoline Abnormal waveforms Loss of alveolar plateau Absent alveolar plateau indicates incomplete alveolar emptying or loss of airway integrity – Possible causes Intubated: Partial airway obstruction caused by secretions Leak in the airway system Bronchospasm Endotracheal tube in the hypopharynx Non-intubated: Head and neck position secretions Classic Hypoventilation Classic Hyperventilation Abnormal waveforms decreased etCO2 Gradual decrease in etCO2 with normal waveform indicates a decreasing CO2 production, or decreasing systemic or pulmonary perfusion Hypothermia (decrease in metabolism) Hyperventilation Hypovolemia Decreasing cardiac output Capnography in Obstructive Lung Disease – – – Waveform shape detects presence of bronchospasm etCO2 trends assess disease severity (e.g., asthma, emphysema) etCO2 trends gauge response to treatment (e.g., asthma, emphysema Abnormal waveforms – rebreathing intubated and non-intubated Rise in baseline CO2 indicates rebreathing of CO2 Intubated patient – Addition of mechanical dead space to ventilator circuit – Technical errors in CO2 analyzer Non-intubated patient Poor head & neck alignment Draping at the airway Insufficient flow to O2 mask Shallow breathing that does not clear anatomical dead space Abnormal Waveforms – What to do Assess patient Check sample line position – reposition or check ET tube position Check head/neck alignment, and open airway, suction if needed Instruct patient to take a deep breath If patient is not breathing and not Movers and Shakers / Clinical Compass ‘The monitoring used in the PACU should be appropriate to the patient’s condition and a full range of monitoring devices should be available’. Canadian Anesthesiologists’ Society, R. Merchant, et al Revised edition 2010 Institute for Safe Medication Practices (ISMP) “Do not rely on pulse oximetry readings alone to detect opiate toxicity. Use capnography to detect respiratory changes caused by opiates, especially for patients who are at high risk (e.g., patients with sleep apnea, obese patients).” – Establish guidelines for appropriate monitoring of patients who are receiving opiates, including frequent assessment of the quality of respirations (not just respiratory rate) and specific signs of oversedation. ISMP Medication Safety Alert, February 22, 2007,Vol. 12, Issue 4 ASA (American Society of Anesthesiologists) Practice guidelines for the perioperative management of patients with obstructive sleep apnea CO2 monitoring should be used during moderate or deep sedation for patients with OSA. If moderate sedation is used, ventilation should be continuously monitored by capnography or another automated method if feasible because of the increased risk of undetected airway obstruction in these patients. Postoperative Management: OSA patients should be monitored for a median of 3 hours longer than the non-OSA counterparts before discharge. Monitoring of OSA patients should continue for a median of 7 hours after the last episode of airway obstruction or hypoxemia. Practice guidelines for the perioperative management of patients with obstructive sleep apnea: a report by the American Society of Anesthesiologists Task Force on Perioperative Management of Patients with Obstructive Sleep Apnea. Anesthesiology 2006 May;104(5):1081-93 Conclusion Capnography for sedation/analgesia/postoperative monitoring: – – – – – Accurately monitors RR Monitors adequate ventilation Monitors hypoventilation due to over-sedation more effectively than pulse oximetry Earliest indicator of apnea and obstruction Adds additional level of safety providing caregiver with objective information to make accurate assessments and timely interventions Be Prepared. Be Proactive Continuing Capnography Education Oridion Knowledge Center: www.capnographyeducation.com Three capnography courses available: A Guide to Capnography during Procedural Sedation – A Guide to Capnography in the Management of the Critically Ill – A Guide to Monitoring etCO2 during Opioid Delivery –