Vicom Systems

advertisement
SAN Data Migration Made Easy
Fast, Assured Enterprise-Wide Migration — Guaranteed
Network Appliance
December, 2007
Vicom Data Mobility Services
• Fast, worry-free SAN migrations with SLA guarantee
Performed by Vicom migration specialist
Uses Unique Data Migration Method
Uses Vicom fabric-based appliance & technology
• Proven in hundreds of migrations at major corporations
Page 2
Satisfied Customers
Bloomberg
Page 3
Data Migration Methodology
Page 4
Vicom Simplifies SAN Management
Transparent, fabric operation with single point-of-control
Simple
Complex
Page 5
SAN Data Migration
destination
source
Manual Data Migration
destination
source
Vicom Appliance-based Migration
•
Labor-intensive, server-by-server task
 Centralized appliance-based control
•
Configuration data needed for each host
 Independent data movement
•
Process unique for each host type
 Host-transparent: no configuration changes
•
Error-prone, data entry process
 Any-to-any storage migration
•
Degrades CPU performance
 Fail-safe with fallback option
Page 6
Technology Advantages
Open, SAN-level services
Any-to-any connection
Multiple, heterogenous hosts
Centralized management
Purpose-built HW/SW
Wire-speed throughput
Host/storage-independent data mover
High reliability
Fabric-based
Operation
Scalable performance
No single point-of-failure
Instantaneous recovery
Built for the
Enterprise
Integrated
Appliance
All-Vicom
Design
Assured interoperability
Vendor-neutral design
Vicom-controlled problem resolution
Page 7
Process Automation Software
• Surveyor – Planning tool
Organize LUN discovery data
Plan migration threads and sequence
• Director – Execution tool
Verify storage connections
Identify LUNs before migration
Monitor migration progress
Fallback provision
Page 8
Vicom Data Migration Service
• Service-based solution, not a product
• Key enablers: SAN synthesis and automation
SAN Synthesis: Migrate data from any to any within
SAN or between SANs
Automation: Actual migration takes hours, not weeks!
• Vicom appliance removed, with no trace in
servers, disks or SAN
• Proven in hundreds of enterprise migrations
Page 9
Success Stories
Page 10
Wells Fargo
•
Provider of banking and financial products and services across
North America and Internationally. Ranked 41st in revenue by
Forbes.
•
Challenges
 Storage Refresh from Xiotech to NetApp, 40 servers 10+ TB. Migrate
data center from production site to shore view, Minneapolis.
 Business requirements: outage window ( < 6 hours), schedule (many
small migrations, 3-month project).
 Absolutely no agents or software installation, and wanted to test the
solution before actual implementation.
 Support for legacy server (Novell Netware), Boot LUN migration and
Xiotech storage.
 Remote migrated 19 servers data as of September 20.
•
Winning Formula: POC, NetApp/Vicom collaboration, Openness to
end user
Page 11
Wells Fargo Deployment
Customer Quote
“Really good news. Thank NetApp and Vicom
so very much. Excellent work and
tremendous effort.”
– Partner
DME1
B
DME2
B
DME3
DME4
B
B
Windows &
Novell
Cisco
Cisco
“Everything went very well, and Vicom
handled their part of the work without any
problems. It was obvious that Vicom people
are knowledgeable and experienced (in data
migrations), and their software tools and
DME appliance all look to work very well. I
have nothing but good things to report, and I
would strongly recommend Vicom for other
SAN migrations.”
- NetApp, Solution Architect
XioTech
NetApp
FAS
Page 12
Assurant
•
Premier Provider of specialty insurance and insurance-related
products and services. A Fortune 500 company and a member of
the S&P 500
•
Highlights
 Storage Refresh from HP EVA to NetApp, 10 TB data for 12 servers
(Solaris & Windows).
 Business outage window cannot be more than 8 hours for each
server.
 HP EVA storage lease expired, and customer was renewing the
maintenance contract for past six months.
 HP EVA and NetApp are connected to different SAN.
 Migrate data in two data centers (Atlanta & Miami) in two different
week-ends.
•
Winning Formula: Reference, Live Demo, Explaining Vicom
process
Page 13
Assurant Deployment
Customer Quote
“Thank you (NetApp and Vicom
team) for helping us during the
migration. It was flawless!”
- System Administrator/Project
Lead, Assurant.
“Vicom demonstrated tremendous
value of migration preparation.”
– NetApp PS Consultant
DME1
B
Windows &
Solaris
A
DME4
B
A
DME 5
Proxy1
B
DME3
B
DME2
B
DME 6
Proxy2
B
DME 7
Proxy3
B
DME 8
Proxy4
Cisco B
Cisco A
B
Filer2
Brocade B
Brocade A
Controller B
Filer1
Filer2
NetApp
FAS
Controller A
Controller A
Filer1
Controller B
HP EVA
Page 14
Esurance
•
Leading online auto insurance provider located in San Francisco.
Founded in 1998, with more than 1700 employees nationwide.
•
Highlights
 Storage Refresh from HP EVA to NetApp with in outage window of
16 hours.
 6.3 TB of data migrated in 9 hours.
 Data migration accomplished in half the maintenance window
•
Customer Quote
“The migration was excellent and went very smoothly, everyone involved
were very professional and it was a job well done. Thank you all for
the smooth migration!”
-
•
Network Engineer, Esurance.
Winning Formula: Success stories, reference, Explaining Vicom
process
Page 15
Esurance Deployment
Single SAN - Esurance
2 Windows Server
6.3 TB in 9Hours
SPB
Controller A
(4 ports)
Controller B
(4 ports)
HP EVA 8000
DME1
B
DME2
B
DME3
B
DME4
B
DME5
B
DME6
B
DME7
B
DME8
B
EMC 4100B
Cisco(CISCO)
MDS 9216A
Controller A
(2 ports)
Controller B
(2 ports)
NetApp FAS3070
Page 16
Closer Look: Vicom Data Migration
SAN/LUN Discovery
Use Surveyor to collect configuration data
Automated Mapping
Map/plan source-to-destination using configuration data
Connection Verification & SAN Synthesis
Mapped connections verified and tested
SAN synthesized (logical paths created) as required
Data Migration
1001011
Appliances migrate data at 1.2 TB/hour
Appliances removed with no traces on server/disk/SAN
Page 17
Vicom Migration Process – LUN Discovery
• Action Items (M-3 Weeks)
•
•
•
•
•
NetApp – Prepare Site Survey.
Vicom – Send Quote
NetApp – Send PO
Vicom – Send Information Gathering Script for Server & Notes.
NetApp – Collect server configuration by running the script.
• Site Survey Form
• Information Gathering Script & Notes
•
•
•
Scripts for Windows, VMWARE, LINUX, AIX, Solaris & HP-UX.
Server Configuration HBA, LVM, File System, Drive (Name, Size, SN).
LUN information from Source Storage Frame (EMC, IBM, NetApp)
Page 18
Vicom Migration Process – LUN Discovery
Sample Information Gathering Output
Page 19
Vicom Migration Process – Planning
Action Items (M-2 Weeks)
• NetApp – Carve LUN and send LUN information.
• Vicom – Use Surveyor to collect & verify configuration data (IBM/EMC/Vicom INQ).
• Vicom – Generate & Send Migration plan.
• Vicom – Send Best Practice for Server Shutdown, Bring-up, and any ‘known’ issues.
Migration Plan
• Action Items: Tasks, responsibility & due date.
• Setup Diagram: Connector, Fabric, Storage ports, Migration Engine & Cable.
Page 20
Vicom Migration Process – Preparation
Action Items (M-1 Week)
•
•
•
•
Vicom – Ship Migration Engines.
NetApp – Complete FC/Ethernet cabling for the DME as per the diagram.
NetApp – Configure Fabric & Storage so that DME can see source & destination LUN.
Vicom – Verify Connectivity & Configuration.
Automated Import Tools
• Import Vicom Drive Inquiry, IBM Specialist Format, IBM DS4000 Format, NetApp
Format*.
• Advanced Import.
Seven Levels of Protection
•
•
•
•
•
•
•
Storage to Storage (Not LUN based)
Storage Type – Source
Storage Type – Destination
Storage WWPN
Drive Source Serial Number
Drive Destination Serial Number
Data in the Destination Drive*
Page 21
Vicom Migration Process – Migration
Action Items (Migration day)
•
•
•
•
Vicom – Coordinate server shutdown (Best Practice).
Vicom – Migrate data from source storage to destination storage.
NetApp – Update HBA BIOS, HBA Driver, FC Driver, MP Driver, OS fixes,.
Vicom – Verify Migration completion and perform post-migration tasks (label
Solaris disk)
• NetApp – Configure FC switch and destination storage to allow server access
destination storage LUN.
• NetApp – Bring-up the server (Best Practice) and Verify user data.
• NetApp – Ship Migration tool back to Vicom.
Fast Migration
• Migration Start Timer Protection (1 minute if fabric attached).
• Tool (4-engine) is able to migrate data at 1.2 TB/hour, Scalable to match
storage speed.
• Manage Migration by reordering, aborting the migration, alter migration thread
and speed.
Page 22
Vicom Migration Process – Migration
Best Practice – Windows Boot LUN Migration
1.
2.
Update HBA BIOS, if needed.
Connect Server HBA to destination SAN (if source SAN is different from destination
SAN). Zone (FC) server HBA and destination storage ports together. Configure LUN
masking so that server can access LUNs from the destination storage.
3. If there are multiple paths to destination storage, connect only one path and
temporarily disconnect all other paths.
4. Configure HBA BIOS setting such that HBA can recognize boot LUN from destination
storage (by WWPN).
5. Bring-up server; boot from destination storage.
6. Install proper multipath driver (Snap Drive) for the destination storage, then shutdown
the server.
7. Reconnect all other paths to the destination storage, and bring-up the system again.
8. Run chkdisk to verify the file system.
9. Examine log files (system, application) for errors and warnings.
10. Start applications and verify user data.
Page 23
Live Demo
Page 24
SAN Setup – Before Migration
Active Zones
1.
SAN-Windows1-HBA1, Source-PortA
2.
SAN-Windows1-HBA2, Source-PortB
3.
SAN-Solaris1-HBA1, Source-PortA
4.
SAN-Solaris2-HBA2, Source-PortB
Solaris
Windows
McData
Sphereon 4500
Source Storage
Page 25
SAN Setup – During Migration
Customer
Active Zone
1.
DME1, DME2, Source-PortA, DestinationPortA
Management
Server
Private Network
DME1
B
Internet
NetApp
DME2
B
Solaris,
Windows
McData
Sphereon 4500
Vicom
EMC 4100B
(CISCO)
Source Storage
Destination
Storage
Page 26
SAN Setup – After Migration
Active Zones
1.
SAN-Windows1-HBA1, Destination-PortA
2.
SAN-Windows1-HBA2, Destination-PortB
3.
SAN-Solaris1-HBA1, Destination-PortA
4.
SAN-Solaris2-HBA2, Destination-PortB
Page 27
Reference Matrix – Any to Any
OS
Middleware
Multipath
Driver
Storage
HBA
Infrastructure
MS Windows
(NT/2000/2003)
MS Cluster
NetApp
Snap Drive
(MPIO)
NetApp FAS
QLogic
Brocade
VMWARE
IBM HACMP
IBM SDD
IBM F20/ESS800/
DS6000/DS8000/SVC
Emulex
CISCO
(VSAN & IVR)
LINUX
HP Service
Guard
EMC Power Path
IBM FAStT/DS4000
(LSI Storage)
JNI
McData
IBM AIX
Symantec Cluster
Sun MPxIO
EMC DMX/
Symmetrix/Clariion
SUN
QLogic
SUN Solaris
Novell Cluster
HP PVLINKS
HP EVA
HP
Inrange
HP UX
Symantec Volume
Manager
Hitachi HDLM
HDS
IBM
Gadzoox
HP 3000 MPE
Power Path Volume
Manager
Qlogic QLDirect
Sun StorEdge/STK
ATTO
IBM San Data
Gateway
NCR
.
Symantec DMP
LSI SVM
.
Nortel Optical
Routers
Open VMS
.
.
ADTX
.
CISCO Optical
Multiplexers
Tru64
.
.
Xiotech
.
Light Sand
Extenders
Novell Netware
.
.
Xyratex
Brocade MPR
AP7420/7500
.
.
.
.
Xserve RAID
.
.
Page 28
NAS Migration
• Migrate internal disk data – Windows and UNIX
• SAN attached data – FC/SCSI/SSA
• NAS data – EMC Celera, NetApp Storage (NFS and CIFS)
• CAS data – EMC Centera
• No host agent
Page 29
Additional Benefits
• No Host Software Agent or Driver required – No configuration
changes.
• External Boot LUN – Windows, AIX, SuSE, Netware, …
• DAS to SAN – FCAL, SCSI & SSA
• SAN to SAN – No ISL; Cisco, Brocade, QLogic, McData, …
• WWN Spoofing – No source storage configuration required (Save
money and time).
Page 30
Additional DMS Service
• Online Migration
• Redundant Fabric
• Fabric to Fabric
• Power Path, SDD, RDAC, MPIO, …
• Disk Volume Re-layout (LUN Stacking)
• Consolidate multiple small LUN to fewer large LUN.
• AIX LVM, Solaris Disk Suite, Solaris VERITAS, HP-UX LVM, NCR
• Data Sanitization
• DoD guideline (6-pattern)
Page 31
Summary
• Turnkey data migration service
Fast, worry-free, guaranteed, highly affordable
Proven - 5 years, 250 migration engagements, 5PB by year end
Vicom is a Network Appliance CDP
• Unique migration service
Appliance-based: Fast, simple, scalable, any to any, SAN to SAN
Staff: Extensive migration experience + know-how
Method: Discovery, Mapping, Verification+SAN Synthesis, Migration
• Inquiries/assistance
Network Storage Practice Distribution List: dl-ngs-ps-practice-nwstoragecv
Engagement Manager: Wei-Gung Wang, +1-650-227-1513, wei-gung.wang@vicom.com
Deployment Manager: Murugan Narayanasamy, +1-650-227-1397, murugan@vicom.com
Page 32
Questions?
Page 33
SAN Data Migration Made Easy
Fast, Assured Enterprise-Wide Migration — Guaranteed
Network Appliance
December, 2007
Download