Dynamic Power Communication power system Non-Electric atomization cooling tower Solution program Beijing Dynamic Power Co., Ltd. Dynamic Power Communication power system Company profile Founded in 1995, Beijing Dynamic Power Co., Ltd. (DPC), the DPC stock (code 600405) officially public listed in Shanghai Exchange April 1, 2004, as the first listed Power Company of china. DPC is a member of China Energy Conservation Service Industry Committee, China Power Supply Society, executive director of Beijing Power Industry Association, National High Technology Health Industry air purification professional committee, clean technology branch of Chinese Institute of Electronics, and the clean technology committee of China refrigeration Air Conditioning Industry Association. In July 2010 , DPC was approved as the key energy services company by Ministry of Industry and Information Technology, the first batch put on records as energy services company by National Development and Reform Commission in August 2010 , Jan.2011 , the most influential companies of the new energy industry in China by National Committee of the Chinese People's Political Consultative Conference , the top ten brands of " contractual energy management in the annual contest of Chinese inverter industry 2010-2011 . DPC owns number of self and patented technology, of which the Non-Electric atomization cooling tower technology is one of the major achievements of science and technology R & D center of DPC, and as the milestone a major breakthrough in the world for the cooling energy saving tower . DPC‘s Non-Electric atomization cooling tower is driven by pressure in the circling circulating water system, with conversion and rational use for the energy, to achieve the refrigeration cooling effect , completely replaced the electric fan of the traditional cooling tower, and reached 100% of the energy saving. DPC actively engaged in R&D of the energy saving for the industry and enterprises , and continue to practice and promote, acceleration the transformation of scientific and technological achievements into practical productive forces , and strive to become a leader in exploration the field of energy saving worldwide, to make contribution for beings . Dynamic Power 1 introduction of product 3 sphere of application 5 technique principle 6 Technical Features 7 products Features 13 service promise 15 cases 16 enterprise honor Communication power system Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Product’s Introduction DPC Non-Electric atomization cooling tower technology is the typical representative of the conversion of film theory to the dispersion theory. It fully use the pressure existed in circulating water system, as a power to rotation the blades, to cool the circulating water. The technology has been included in the catalog of science and technology promotion. NSTB DPC Non-Electric atomization cooling tower composed by fan drum , water spraying plate, water collector, and atomization device which doubled the function of the atomization and the blast for spray propulsion, completely replaced the electrical blower and the cable, distribution cabinet , control cabinet etc, as well as eliminating the packing . Non-Electric atomization cooling tower, the epoch-making product, in addition to have the benefits of 100% electricity saving, it is also have the advantages such as Water conservation, lower requirements of water pressure, cost reducing, good effect of cooling, low noise, no plug, safe use and easy maintenance, strong generality, no special requirements on water quality etc: it is widely used in the variety of the filed with its broad applicability and excellent quality. 实用新型专利证书 New Style and Utility certificate New Style and Utility certificate Mark of product MDPW G G 1000 F P P is for the water-collecting tray, unmarked for no water-collecting tray. F is for the square and none if it is round. Tower specifications, represents the flow in certain of the cases. G- Means the steel frame structure, Unmarked for the concrete frame. G- Industrial type, D- common type. Non-Electric atomization cooling tower The standard design cases: design parameters MDPWG (D) Series industrial cooling towers inlet water temperature ( C ) effluent water temperature(C) 37 32 40 32 43 33 65 45 Design temperature difference Δ1 (C) 5 8 10 20 dry Bulb Temperature ( C) wet Bulb Temperature ( C) 31.5 28 atmospheric pressure MPa 0.0994 Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor 冶金 metallurgical 电力 electricity 制药 pharmaceutical, 楼 the hotels office building 化工 chemical 冷却塔 cooling tower 酒店办公 I .petroleum, chemical industry( oil refining, ethylene, plastic, polyester) 2. Thermal power plants (factory - owned power plants, coal gangue power plant, and firepower electrical plant) 3. Metallurgical industry,( iron and steel . aluminum , cokery , oxygen, iron alloy , Copper ) 4. fertilizer (large , medium , and potash ) nitrogenous fertilizer , urea , nitric cymbals , iodine fertilizer , 5. chemical ( coordinative producing alcali,PVC, methane chloride, organic chemicals) 6 .light industry ( paper , beer , vacuum salt, cigarette factory ) 7. Electronics industry 8. Pharmaceutical industry, biochemical industry 9. Photosensitive material Industrial 10. HVAC 11Textile, chemical fiber The leader of the safety and energy conservation The Cooling tower is important in the whole process. It is important to meet the requirements of process and ensure the stableness, for the safety process operation. DPC has first come forward the " safety and energy saving" conception in the industry, with its product DPC Non-Electric atomization cooling tower has put the first priority for the ensure safety production and meet the process requirements, which realized through the science management . 1. The state-of-the-art design concept, ensures 100% meet the requirements for the temperature drop during the process. 2 through the rigorous site exploration, data argumentation and the deeply investigation of the requirements of craftsmanship, the scientific of the production, renovation and construction scheme can be ensured. 3 the operation stability can be ensured since no need the motor and packing. 4 the elimination of electricity and little water-drift, the hidden trouble of the safety can be eliminated. 5.The strict construction organization ensures the design criteria and construction schedule. The actual picture of the DPC's Non-Electric atomization cooling tower Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Technique principle DPC Non-Electric atomization cooling tower, take full use of the press existed in the circulating water system. the press water goes into the " fog Spray rotating device" on the bottom of the tower through the inlet pipe and turned to be the spray fog sprayed from the nozzle, under the push force by the fog spray the nozzle and the blade are rotated at the same time, by which rotation force, the central fugal is generated to increase the pressure of the flow centrifugal, and the spray flow is even faster. In turn, it also accelerates the atomization and increased the speed of atomization rotation, finally conversion the most of the energy of the water into the wind energy, enable the hot water fog flow and the cold air to be fully exchanged, and then the purpose of dropping temperature by the circulating water is reached. Spray rotating device pictures The real chart of the DPC's Non-Electric atomization cooling tower construction 湿热 damp-heat ;空气 air ;一次冷却水 primary cooling water; 喷雾装置 Spray rotating device 淋水区 water spraying Zone;二次冷却水 secondary cooling water;多通道补风 Multi- channel makeup air 多通道补风 Multi- channel makeup air; 集水盘 water-collecting tray; 进水管 Inlet pipe 回水管 return pipe Technical characteristic The design feature of the DPC Non-Electric atomization cooling tower makes it even more stable and desired and has better effect of cooling results than traditional cooling tower. 1 the water can be dispersed into the fine corn into the fog shape through the dispersal device , which can make the cold air and the particulate of the water be evenly contact, which largely increase the exchange area and efficiency of exchange. 2, there are three processes for the water in the cooling water, including: upward, suspension, and decrease. While there are both down stream cooling and counter flow cooling, enable it to contact even longer with dry and cold air, and take away more heat. 3 the isolation of the water spraying board and the body of tower, avoid the return air and the several of the atomization device mutual interfering, and at same time, the fog flow can make the second time ejector air. The mutual of the superimposed on mechanical ventilation and the ejector air, increase the gas-water ratio. 4, the reasonable configured air channel and the water spraying device , features of the air resistance small , the reasonable wind farm, and low partial pressure of steam. Spray effect diagram Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Products Features 1.100% power saving. No electric drive. : 2.Low cost of normal daily maintenance: free cost of maintenance the motor, and free expense on large amount of packing exchange. 3. Good result of cooling effect and stable of the maintenance e of temperature drop: the water within the tower is exchanged with the inlet air on the fog condition; there is no blog of the packing and damage of motor, the stable of drop temperature. 4 small water-drift rate, the excellent performance of water collection device on the top of the tower, can save the 20% water than the packing cooling water tower. 5. The mute design ensures the low noise: the equipment is especially applicable for hotels, restaurants, hospitals, schools and surrounding neighborhoods, without the motor, so free of the noise of rotating machinery and equipment. 6. the safety operation can be ensured: Without the motor so the electric fire during the operation can be avoid, neither the shut down accident caused by the blow happened. 7. there is no attenuation cooling problems: a large amount of packing is eliminated, so the disadvantages of the attenuation caused by the large amount of the packing after fouling and iching can be overcome. 8. simple maintenance: complete elimination the trouble of frequent cleaning, replacement of packing, and distribution water nozzle. 9. Reliable operations: due to eliminating the motor, the distribution cabinet distribution cabinet, and the control cabinet etc which controlled the motor fan, to exclude the various factors that affect the stable operation. 节电 100% 100% power saving ; 静音设计 mute design ; 去除填料 Remove the packing 对水压要求小 Low requirements on pressure; 适用面广 Widely application 静音设计 Mute design; 飘水率小 Low rate of water-drift 10 no special requirements on water pressure: it can apply the renovation on almost all traditional cooling towers, which can be better reflect the technical advantages for the project which taken the pumping water system energy saving. 11 No special requirements on water quality: the diameter of atomizing nozzle is greater than 12, not easy to be clogging, , and large velocities of the nozzle flow make the fouling hardly to be shaped. 2 the adjustable amount of cooling water: for the given model of the cooling tower, can increase the water supply pressure and change the nozzle aperture to adjust the amount of water and temperature drop. 13. The light body, flexible combination: reduced the requirements for the base, variety of the combination of the units, enable it to be flexible combined according to the sites, for the required more amount of cooling water , better reflects the advantage of the techniques. Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor The reference table for the power Content cooling tower specifications (T / h) 100 200 300 400 500 600 1000 2000 4000 DPC Non-Electric atomization cooling tower wind turbine power (Kw) traditional cooling tower Conclusions Daily electric consumption(Kw) the annual power consumption (Kw) Traditional tower Traditional tower Trad itional tower 4 7.5 11 15 18.5 22 40 80 160 DPC Non-Electric atomization cooling tower 0 0 0 0 0 0 0 0 0 96 180 264 360 444 528 960 1920 3840 DPC Non-Electric atomization cooling tower 0 0 0 0 0 0 0 0 0 34560 64800 90504 129600 159840 190080 345600 691200 1382400 DPC Non-Electric atomization cooling tower 0 0 0 0 0 0 0 0 0 The parameters comparative with the traditional tower Content DPC Traditional tower Non-Electric Comparative conclusions atomization cooling tower Δt ±0.5oC Δt Obvious cooled 7.5mm H2O 13mmH2O Reduce42% Motor power 0 45KW Reduce 45KW Gas-water ratio 550: 1 450:1 Increase22% cooling water 1000 1000 Uniform Un-uniform Clogging No yes Channeling No serious (packing) aging No serious no Frequently clean and Performance cooling parameter temperature( Δt) systemic resistance ( Δt) amount (m/m) distribution temperature Operation parameter mo deformation Maintenance maintenance Maintenance parameter Replace packing, 5 year great labour intensity 5 years 3years Extend 2 years Service life 20 years 8 years Extend Water-drift Seldom yes 20% water saved Acoustic noise A-8dB A Reduce 8dB etc. Continuous operation cycle Ambient Electricity saved 100% 12 years Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Compare to the traditional tower performance: Electric consumption Water consumption Operation cost Reliability DPC Non-Electric atomization cooling tower Without Power Consumption no need regular replenishment need low capable of continuous operation Safety Can work in any explosion-proof area of Environment protection contamination free generality, applicable for any cooling tower which need the mechanical ventilation, and can do renovation any cooling tower traditional cooling tower 100 Ton circulating water Power Consumption of 4-6 KW Need regular replenishment high Frequently required for the motor and reduction gearbox with daily maintenance Need to install the explosion-proof motor, electric control device affect the environment by water-drift , and noise applicable for any cooling tower which need the mechanical ventilation Transformation process Early communication site survey Programming: ---to understand the customers transform needs of Collection the data of the old tower Pump lift, Fan power, inlet water pressure , pipe diameter According to the first information collected on the site, and combined with the requirements of the old tower to make the program of renovation. contract confirmation Renovation implementation The renovation include: the design of the " spray rotary device " die opening, site of installation, , post- commissioning, so on the specific work . Project acceptance Consideration three areas a lot of the traditional old cooling towers remain in the service cycle, our company provide the renovation for old tower with “Non-Electric". Permitted by the condition, we can renovate any old cooling towers with “Non-Electric" renovation Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Service promise The company has established the service guarantee system with 30s of the offices including the customer service center, the professional service guarantee team composed with 200s people, to provide the technique support, training, remote techniques diagnosis , diagnosis, logistics , on-site technical services and engineering construction etc. Through the means of modern information ( the video system application) , it has established 1 first class store reserve and over 30s second class of the spare parts reserve storehouse, with 24 hours service hotline , guaranteeing the information communication between the customers and the company. Whole course service Response to Technical query Prepare Technical bid- Feedback from Branch Office On-site technical exchanges COMPANY service promise Conclusion a technology agreement Technical personnel on-site Prepare data collection technology program Equipment inspect in Plant User training, acceptance Routine Equipment file maintenance, inspection Start up the devices on field Onsite fault maintenance Telephone Maintenance guidance for Onsite fault feedback Introduction of product sphere of application technique principle Technical Features products Features service promise cases enterprise honor Example illustrates Take a steel plant as an example, in 2008, the cooling tower of the steel plant was renovated as the Non-Electric type of cooling tower. For example , a cooling tower of 1200 m3 / h, which with the electricity charged 0.55 Yuan/Kw, 24 hours a day and 330 days/year, the annual electricity savings by using MDPEG series of the Non-Electric atomization cooling tower as: 45KWX24 hours X330 days X0.55 Yuan / kWh X1 =196,020 Yuan, in which the fan motor is replaced. It saved the costs( total power consumption 6%) by motor repairing and maintenance is: 196020 x 0.06 = 11761 Yuan; after the renovation the total saving cost of the year approximately : 196020 +11761 = 207,781 Yuan; reducing loss of the water-drift after renovation :1200013x1 X330 - day X24 hours X 0.002 X 3.8 Yuan / ton = 72,230 Yuan ; save packing cost annually about 5,000 Yuan . total saving cost of the year approximately : 207781 + 72230+ 5000 = 207,781 Yuan after the renovation. he investment in equipment can be returned with one year, which shows the considerable economic and environmental benefits . Honors 北京动力源科技股份有限公司 Beijing Dynamic Power Co., Ltd. 中国电信行业通信工程建设优秀服务商 The excellent facilitator in communication engineering construction of China telecommunications industry 守信企业 Promise-keeping enterprise 北市工商行政管理局 Beijing Administration for Industry and Commerce 高新技术企业 High-tech Enterprise 证书 Certificates 中国电源行业诚信企业 China Power Supply Credit Enterprise 中国电子商会电源专业委员会 China Electronic Chamber of Commerce Power specialty committee 中国新能源产业经济发展年会 Annual Meeting of the China 's new energy industry economic development 2010 中国新能源产业最具影响 2010 China 's most influential enterprises in new energy industry 北京动力源科技股份有限公司 Beijing Dynamic Power Co., Ltd. ECPA ECPA 会员单位 Member unit 北京中关村企业信用促进会 Beijing Zhongguanchun Enterprises Credit Promotion Association 奖状 Certificate of merit 优秀企业 Excellent Enterprise 中关村科技园区 Zhongguancun Science and Technology Park 创新型试点企业 Innovative type pilot enterprises 中国电源产业技术创新 China Power industrial Technology Innovation 会员证 Member certificate