TTH Trans Tech ------------------------TRANSFORMER Department Trans Tech Handels GmbH Form No.: TTH/P-01 Ausser der Schleifmuehle-37 28203 Bremen-Germany Sheet: 01 of 02 --------------------------------------------------------------SCHEDULE OF TECHNICAL PARTICULARS FOR POWER TRANSFORMER REFERANCE No.: CUSTOMER: SR. DESCRIPTION NO. HV Winding 1. KVA Rating LV Winding TERT. Winding HV Winding Rated No load 2. LV Winding Voltage TERT. Winding 3. Rated Frequency 4. 5. 6. 7. UNIT MVA MVA MVA kV kV kV Hz Number of Phases HV Winding Connections LV Winding TERT. Winding Connection Symbol (Vector Group) Tapping Details i) Tapping Range ii) Number of steps iii) For high voltage variation / for intermediate voltage variation / for low voltage variation iv) OLTC or Off Circuit Tap Switch 8. Type of Cooling * 9. Temperature Rise * 10. Losses i) No Load Loss at rated voltage on principal tapping and at rated frequency ii) Load Loss at rated current at principal tapping, at rated frequency at 75 °C iii) Auxiliary Loss Impedance voltage at HV – LV Principal tap HV – TERT. * 11. 12. Top Oil Winding °C °C kW KW kW LV – TERT. % % % HV Winding kV rms LV Winding TERT. Winding kV rms kV rms Insulation Level i) Separate source power frequency voltage withstand PARTICULARS ` TTH Trans Tech -------------------------TRANSFORMER Department Form No.: TTH/P-01 Trans Tech Handels GmbH Ausser der Schleifmuehle-37 28203 Bremen-Germany ------------------------------------------------------------------------- Sheet: 02 of 02 SCHEDULE OF TECHNICAL PARTICULARS FOR POWER TRANSFORMERS SR. DESCRIPTION NO. 12. ii) Induced over HV Winding (Cont.) voltage LV Winding withstand TERT. Winding iii) Impulse voltage HV Winding withstand LV Winding TERT. Winding 13. Efficiency at 75 °C at at full load at ¾ full load unity power factor at ½ full load 14. Regulation at full load at unity power factor at 75 °C at 0.8 power factor 15. Terminal Arrangement High Voltage UNIT PARTICULARS kV rms kV rms kV rms kVp kVp kVp Low Voltage 16. TERT. Voltage Approximate Weights Core and Winding Tank, Fittings and Accessories Oil Total Weight 17. 18. 19. Approximate Overall LxWxH dimensions Dispatch Details i) Approximate Weight of heaviest package ii) Approximate Transport LxWxH dimensions of largest package Reference Standards IEC/BS/DIN….. kg kg Kg Kg Mm Kg Mm Parameters against SR. NOS. marked with astrix ‘*’ are guaranteed. Remarks: Please fill up as much as possible to get proper quotation. Items from 1 to 12 are most important to get any meaningful quotation. Other items if known will help us to do even better. Design Department/International Sales Department