May-14 TEST REPORT TEMPLATE FOR AIR-CONDITIONER MODELS (AIR-ENTHALPY METHOD) [COVER PAGE TO BE PRINTED ON TESTING LABORATORY’S COMPANY LETTERHEAD] Test Report for Air-Conditioner [Model Number] [Test report reference number] Section 1: Testing Laboratory a) Date of test (dd/mm/yy) b) Name of testing laboratory c) Location of testing laboratory d) Name and designation of testing officer e) Name and designation of approving officer Section 2: Product Specification1 a) Brand b) Type c) Phase d) Climate type e) Country of origin f) Type of refrigerant g) Total refrigerant charge (kg) h) Model number i) Voltage (V) j) Frequency (Hz) k) Current (A) l) Weight (kg) m) Overall dimensions (h x w x d) (mm) n) Crankcase heater (W) o) Rated total cooling capacity at 100% load & 50% load (W) p) Rated power input at 100% load & 50% load (W) Section 3: Cooling Capacity Test a) Test standard b) Test method Air enthalpy 100% load c) Applied voltage(s) (V) d) Frequency (Hz) e) Current (A) f) Duration of test (hr) g) Total cooling capacity (W) h) Sensible cooling capacity (W) i) Latent cooling capacity (W) j) Effective power input to equipment or individual power inputs to each of the electrical equipment components (W) k) Total power input to equipment and its components (W) 1 For 2 split type air-conditioners, data for indoor and outdoor units must be included For split type inverter air-conditioners only 50% load2 May-14 100% load 50% load2 l) Coefficient of Performance (COP) (W/W) m) Lowest COP3 (Yes/No) n) Barometric pressure (kPa) o) Fan speed setting (RPM) p) Indoor-side air-flow (m3/s of standard air) q) External resistance to air-flow for each indoor unit (Pa) r) Volume flow rate of air and all relevant measurements for its calculation (m3/s) s) Dry-bulb temperature of air entering equipment (ºC) t) Wet-bulb temperature of air entering equipment (ºC) u) Dry-bulb temperature of air leaving measuring device (ºC) v) Wet-bulb temperature of air leaving measuring device (ºC) w) Outdoor dry-bulb and wet-bulb temperatures (ºC) x) Setting of variable capacity compressor Section 4: Energy consumption test (Standby mode) a) Test standard Measured value b) Voltage (V) c) Frequency (Hz) d) Ambient temperature (ºC) e) Standby Power4 (W) f) Procedure for Standby Power testing (E.g. 5.3.2 or 5.3.3 or 5.3.4 of IEC 62301:2011) Section 5: Signatures Name and signature of testing and approving officers Date Appendix A – Photos Color photos showing the exterior and interior of the registered model in the available finishing and colors Color photo showing the number of connectors on the outdoor unit Color photo of the nameplate Appendix B – Schematic Drawing Schematic drawing clearly indicating the model’s key internal components Appendix C – Component List Technical specification and description of the model’s key internal components 3Tested 4 with compatible indoor units that will result in lowest COP For indoor and outdoor units May-14 Appendix D – Table Showing the Ratio of the Total Cooling Capacity of the Indoor Units to the Cooling Capacity of the Outdoor Unit Model no. Full/Part load Outdoor unit 1 Cooling capacity (kW) Indoor unit 2 3 4 5 Total Ratio