Centrifugal Roof Exhaust Fans Models H-G and H-GB Downblast High Wind & Hurricane Fans, Miami-Dade NOA# 07-0503.07 November 2007 Models H-G and H-GB ® The Greenheck Models H-G (direct drive) and H-GB (belt drive) are centrifugal roof exhaust fans designed specifically for high wind applications, such as hurricanes, tornadoes, and other high wind areas. The down blast design is ideal for general clean air applications where air is discharged directly onto the roof surfaces. Performance ranges up to 14,000 cfm (24,000 m3/hr) and up to 2.75 inches wg (700 Pa). High winds can reach upwards of 150 mph in much of the world. At these elevated wind speeds roof top equipment can see a force of over 750 pounds (340 kg). High winds and extreme forces are the cause of most storm damage. In 2005, over $125 billion dollars in damage is linked to high winds and storms. Third Party Certified • Miami-Dade NOA # 07-0503.07. • Withstands wind loads up to 150 mph. • P.E. (Professional Engineer) calculations available. • Tested to ASTM and Florida Building Code standards. • No tie downs to roof required. • Installation details provided. High Wind Resistance is Assured • Internal Bracing - High strength internal support structure and bracing. • Shroud - Drawn shroud with integral rolled bead for consistent material thickness and strength. • Drive assembly - Motor and drive frame are mounted on true vibration isolators, and sized for 150% of maximum driven horsepower. • Roof Curb - High wind roof curb is provided and tested as an assembly. Remember that the H-G and H-GB are the only powered roof exhaust fans that are tested and certified to withstand 150 mph winds. *UL/cUL is optional and must be specified. H-G & H-GB models are listed for electrical (UL/cUL 705) File no. E40001 Greenheck Fan Corporation certifies that Models H‑G and H-GB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The certified ratings for Models H-G and H‑GB are shown on pages 10 to 39. Leading Edge Technical Support When you need extensive product and IOM (Installation, Operating and Maintenance Manual) information, our products are supported by the industry’s best product literature, electronic media, and Computer Aided Product Selection (CAPS) program. You’ll also find this information on our website at www.greenheck.com You can always count on personal service and expertise from our national and international representative organization. To locate your nearest Greenheck representative, call 715-359-6171 or visit our website at www.greenheck.com High Wind Force Standards ® Greenheck is leading the High Wind Standard for roof top fans and ventilators. By analyzing calculations, computer simulations, actual testing, and other standards Greenheck developed the High Wind Standard. Outside Curb Dimension Use 3/8 inch (10 mm) expansion anchor or equal into concrete. Fasteners one each corner as detailed. H-GPF Curb Height 8 to 18 inches (203 to 457 mm) (Optional 24 inch (610 mm) SD Curb) 1 inch (25 mm) Insulation Each side at center of unit. Maximum fastener spacing of 8 inches (203 mm), add additional fasteners to satisfy. Roof Opening 21/2 inch (64 mm) Embedment Recommended minimum 15/8 inch (41 mm) Minimum Concrete Strength of 2000 PSI Minimum 13/4 inch (44 mm) edge distance 5 inch (127 mm) Mounting Flange Center fasteners on flange Outside Flange Dimension • Structural calculations performed by a state licensed Professional Engineer (P.E.) to verify the 150 mph (61 psf) capability of each fan and roof curb assembly. These calculations include Finite Element Analysis (FEA) and a stamped P.E. report of the fans compliance to ASCE 7-02 Minimum Design Loads for Buildings and Other Structures Standard snd the Florida Building Code. • Detailed report specifying appropriate size, number, and spacing of fasteners attaching the fan to roof curb and to affix roof curb to building, performed and stamped by a licensed P.E. • Certified independent third party testing completed in accordance with ASTM Standard E330 and Miami-Dade Test Protocol TAS202, Static Pressure Difference. The report includes one set of manufacturer’s design drawings marked and verified by the certified testing laboratory. All tests are video taped for documentation of test method and results. What you get from Greenheck – One Step Further CONCRETE DECK ANCHORING DETAIL Government Certification The H-G and H-GB Models are the only downblast aluminum fans in the industry that have received a Miami-Dade NOA for high wind (150 mph) and hurricane zones. (NOA # 07-0503.07). State Licensed P.E. Calculations The H-G and H-GB Models have been analyzed and stamped by a state licensed P.E. to the ASCE 7-02 Standard which meets the IBC, Florida and Miami-Dade codes. Both models have been proven to withstand winds in excess of 150 mph (61 psf). Testing Each of the Greenheck models have been subjected to extensive testing procedures. The H-G and H-GB have been certified by an independent third party to the ASTM E330 Static Pressure Difference Standard and TAS-202 static pressure difference Florida Building Code Test Protocol. Computational Fluid Dynamics (CFD) All Greenheck high wind models have been analyzed using Computational Fluid Dynamics (CFD). CFD is computer software designed to simulate the flow of high speed (150 mph) winds over the surface of objects. The software records the force profile exerted on the fan, so it can be utilized in Finite Element Analysis (FEA). Finite Element Analysis (FEA) Utilizing the results from CFD analysis Greenheck can accurately predict the stress, strain, and deflection resulting from high wind loads. Greenheck high wind units have been proven to withstand 150 mph winds through Finite Element Analysis utilizing CFD results. Standard Construction Features Roof Curb - High wind load fans are certified with one of two Greenheck high wind roof curbs. Standard 12 inch (305 mm) in height H-GPF curb has a 5 inch (127 mm) flashing flange. Roof curbs ship separate for field installation with attachment details provided. Internal Supports - Heavy gauge supports and bracing are added for additional strength to withstand a wind of 150 mph. Wheel - An aluminum, backward-inclined, nonoverloading centrifugal wheel is utilized to generate high efficiency and minimal sound. Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is robotically welded and statically and dynamically balanced for long life and quiet operation. Disconnect Switch - NEMA-1 switch is factory mounted and wiring is provided from the motor as standard (other switches are available). All wiring and electrical components comply with the National Electric Codes (NEC) and are either UL listed or recognized. Internal Conduit Chase - A large diameter conduit for installing electrical wiring through the curb cap into the motor compartment. Fan Shaft - Is precisely sized, ground, and polished so the first critical speed is at least 25% over the maximum operating speed. Where the shaft makes contact with bearings, close tolerances result in longer bearing life. Bearings - 100% factory tested and designed specifically for air handling applications with a minimum (L10) life in excess of 100,000 hours (L50 average life of 500,000 hours). Motor Cooling - Cooling fins located on top of fan wheel draw outside air through a large space between the fan shroud and the motor cover directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life. ® Motor - Carefully matched to the fan load and is mounted out of airstream. Motor Cover - Constructed of aluminum, machine punched, and attached with stainless steel hardware for easy removal and access to motor compartment and drive assembly. Drive Assembly - Belts, pulleys, and keys are oversized 150% of driven horsepower. Machined cast pulleys are adjustable for final system balancing. Belts are static free and oil resistant. Vibration Isolation - Vibration isolators support the drive assembly and wheel for long life and quiet operation. Fan Shroud - One piece, heavy gauge aluminum with a rolled bead for extra strength directs exhaust air away from the mounting surface. The curb cap and integral deep spun venturi are attached to the windband and also constructed of aluminum to prevent corrosion. Nameplate - Permanent stamped aluminum plate for exact model and serial number identification. Galvanized Birdscreen - Galvanized rigid wire protects the fan’s discharge from birds or small objects. Curb Cap - Curb cap (with integral deep spun venturi) is constructed of aluminum and is one piece for a weather-tight fit. Lower Windband - Heavy gauge aluminum with formed edges for added strength and provide weather resistance. Lifting Points - Select models have various lifting points located on the drive frame and bearing plates. Motor Cooling Space ® Birdscreen Bearing Plate Lifting Points Lower Windband Curb Cap Drive Frame Lifting Points Fan Shaft Motor Cover Bearings Drive Assembly Disconnect Switch Motor Conduit Chase Fan Shroud Shroud Brace Vibration Isolators Internal Supports Wheel Nameplate Roof Curb with 5 inch (127 mm) Flashing Flange Sizes 260 and Larger Require Tie Downs (Included) Options and Accessories ® Roof curbs are provided as a standard with the H-G and H-GB. The roof curb ships separate to allow for finishing of the roof prior to the fan installation. • H-GPF is standard at 12 inch (305 mm) in height for typical applications. • H-GPF is available up to 18 inch (460 mm) in height to meet greater height requirements. • SD (Severe Duty) curbs are available to meet 24 inch (610 mm) curb requirements. • Mounting details for the roof curb to the roof substrate and the fan to the roof curb are included with each H-G and H-GB fan. Birdscreen - Galvanized mesh is standard, optional aluminum or stainless steel rigid wire are also available. Coatings - Wide variety of coatings and colors are available. Greenheck coatings and resistance charts can be found in the coatings bulletin. Disconnect Switches - A wide selection of NEMA rated switches are available for positive electrical shutoff and safety, including: dust-tight, rainproof, and corrosion-resistant. Switches may be internally or externally mounted. Dampers - Designed to prevent outside air from entering back into the building when fan is off. Includes: gravity and motorized dampers. Damper sizes are shown on each performance data page. Tie Down Points - Four brackets located on the shroud for securing the fan in heavy wind applications. Cables and anchors by others. Speed Controllers - Available for use with shaded pole and permanent split capacitor (PSC) open motors on Model H-G fans. They provide an economical means of system balancing with direct drive fans. Curb Seal - Rubber seal between fan and curb to assure proper sealing when attached to a curb. H-G and H-GB models are listed for electrical (UL/cUL 705) File no. E40001 Model Number Code ® The Model Number Code is designed to completely identify the fan. The correct code letters must be specified to designate belt or direct drive. The remainder of the model number is determined by the size and performance. H - GB - 240 HP - 5 Motor HP (Belt Drive only) Model 6 4 3 5 7 H - High-Wind / Hurricane Fan Configuration G - Direct Drive GB - Belt Drive = = = = = 1/6 1/4 1/3 1/2 3/4 10 15 20 30 = = = = 1 11/2 2 3 50 = 5 75 = 71/2 100 = 10 150 = 15 Fan Size 060 through 300 Motor RPM (Direct Drive only) A = 1725 B = 1140 C = 860 Pressure Level (Belt Drive only) HP - High Pressure Wheel D = 1550 E = 1050 G = 1300 Typical Installation Models H-G and H-GB exhaust fans are designed to meet the needs of general clean air applications. Tests were conducted to assure safe, rugged and reliable fans. Factory Wired from Motor to Disconnect Due to the varying airstreams encountered in commercial ventilation, system designers must be aware of national, state, and local codes and guidelines governing these installations. Local code authorities should be consulted before proceeding with any ventilation project. Roofing materials can extend to the top of the curb, roof curbs should be 1 inch (25 mm) total, or 1/2 inch (13 mm) on each side, less than the unit curb cap to allow for roofing and flashing. 1/4 in. (6 mm) Fastener 1/2 in. (13 mm) Wiring by Others For recommended duct size, damper size, and roof opening dimensions, refer to the performance data pages. Damper 11/4 in. (32 mm) Installation must include a means for inspecting, cleaning and servicing the exhaust fan. 8 - 24 in. (203 - 610 mm) H-GPF or SD Curb 4 in. (102 mm) From Curb Edge Poor Recommended Duct and Damper Size 11/4 in. (32 mm) Poor Go Recommended Roof Opening Fan Inlet Connections In order to assure proper fan performance, caution must be exercised in fan placement and connection to the ventilation system. Obstructions, transitions, poorly designed elbows, improperly selected dampers, etc., can cause reduced performance, excessive noise, and increased mechanical stress. For performance to be as published, the system must provide uniform and stable airflow into the fan. Good Poor Poor Good Typical Anchoring ® Concrete Deck Anchoring Use 3/8 inch (10 mm) expansion anchor or equal into concrete. Fasteners one on each corner as detailed. Outside of Roof Curb (1 inch (25 mm) less than) Fan Curb Cap Each side at center of unit. Maximum fastener spacing of 8 inches (203 mm), add additional fasteners to satisfy. 11/4 inch (32 mm) H-GPF Curb Height 8 to 18 inches (203 to 457 mm) (Optional 24 inch (610 mm) SD Curb) 11/4 inch (32 mm) 1 inch (25 mm) Insulation Roof Opening 21/2 inch (64 mm) Embedment Recommended. Minimum 15/8 inch (41 mm). Minimum Concrete Strength of 2000 PSI Corner Detail Minimum 13/4 inch (44 mm) edge distance CORNER TOP VIEW Center fasteners on flange 5 inch (127 mm) Mounting Flange Outside Flange H-G Size H-GB Size 060 - 075 - 17 x 17 (432 x 432) 080 - 095 - 101 - 121 071 - 131 131 - 141 141 - 161 22 x 22 (559 x 559) 150 - 26 x 26 (660 x 660) 160 - 180 180 - 200 - Fan Curb Cap Roof Opening Fasteners Per Side 101/2 x 101/2 (267 x 267) 5 26 x 26 (660 x 660) 17 x 17 (432 x 432) 121/2 x 121/2 (318 x 318) 5 26 x 26 (660 x 660) 19 x 19 (483 x 483) 141/2 x 141/2 (368 x 368) 5 28 x 28 (711 x 711) 181/2 x 181/2 (470 x 470) 5 31 x 31 (787 x 787) 181/2 x 181/2 (470 x 470) 5 35 x 35 (889 x 889) 30 x 30 (762 x 762) 201/2 x 201/2 (521 x 521) 7 39 x 39 (991 x 991) 220 - 240 34 x 34 (864 x 864) 261/2 x 261/2 (673 x 673) 7 43 x 43 (1092 x 1092) 260 - 300 40 x 40 (1016 x 1016) 321/2 x 321/2 (826 x 826) 7 49 x 49 (1245 x 1245) CONCRETE DECK ANCHORING DETAIL Outside Flange All dimensions in inches (millimeters). Metal Building/Steel Deck Anchoring Use #12-14 self-drilling screws or equal. Outside of Roof Curb (1 inch (25 mm) less than) Fan Curb Cap H-GPF Curb Height 8 to 18 inches (203 to 457 mm) (Optional 24 inch (610 mm) SD Curb) 11/4 inch (32 mm) 11/4 inch (32 mm) Fasteners one on each corner as detailed. Each side at center of unit. Maximum fastener spacing of 8 inches (203 mm), add additional fasteners to satisfy. 1 inch (25 mm) Insulation Roof Opening Corrugated Roof Deck Minimum 12 Ga. Steel Corner Detail Roof Truss 5 inch (127 mm) Mounting Flange CORNER TOP VIEW Center fasteners on flange Outside Flange H-G Size H-GB Size 060 - 075 - 17 x 17 (432 x 432) 080 - 095 - 101 - 121 071 - 131 131 - 141 150 Fan Curb Cap Roof Opening Fasteners Per Side 101/2 x 101/2 (267 x 267) 5 26 x 26 (660 x 660) 17 x 17 (432 x 432) 121/2 x 121/2 (318 x 318) 5 26 x 26 (660 x 660) 19 x 19 (483 x 483) 141/2 x 141/2 (368 x 368) 5 28 x 28 (711 x 711) 141 - 161 22 x 22 (559 x 559) 181/2 x 181/2 (470 x 470) 5 31 x 31 (787 x 787) - 26 x 26 (660 x 660) 181/2 x 181/2 (470 x 470) 5 35 x 35 (889 x 889) 160 - 180 180 - 200 30 x 30 (762 x 762) 201/2 x 201/2 (521 x 521) 7 39 x 39 (991 x 991) - 220 - 240 34 x 34 (864 x 864) 261/2 x 261/2 (673 x 673) 7 43 x 43 (1092 x 1092) - 260 - 300 40 x 40 (1016 x 1016) 321/2 x 321/2 (826 x 826) 7 49 x 49 (1245 x 1245) All dimensions in inches (millimeters). Outside Flange Typical Anchoring Continued Wood Deck Anchoring ® Use #12 Wood Screws or equal into minimum No. 1/No. 2 Southern Pine wood support. Outside of Roof Curb (1 inch (25 mm) less than) Fan Curb Cap 11/4 inch (32 mm) Each side at center of unit. Maximum fastener spacing of 6 inches (152 mm), add additional fasteners to satisfy. 1 inch (25 mm) Insulation H-GPF Curb Height 8 to 18 inches (203 to 457 mm) (Optional 24 inch (610 mm) SD Curb) 11/4 inch (32 mm) Fasteners one on each corner as detailed. Roof Opening 2 inch (51 mm) Minimum Embedment Wood Decking Corner Detail 5 inch (127 mm) Mounting Flange CORNER TOP VIEW Center fasteners on flange Wood Support Member Nominal 2 x 4, 6, 8 Outside Flange H-G Size H-GB Size 060 - 075 - 17 x 17 (432 x 432) 080 - 095 - 101 - 121 071 - 131 131 - 141 150 Fan Curb Cap Roof Opening Fasteners Per Side Outside Flange 101/2 x 101/2 (267 x 267) 5 26 x 26 (660 x 660) 17 x 17 (432 x 432) 121/2 x 121/2 (318 x 318) 5 26 x 26 (660 x 660) 19 x 19 (483 x 483) 141/2 x 141/2 (368 x 368) 5 28 x 28 (711 x 711) 141 - 161 22 x 22 (559 x 559) 181/2 x 181/2 (470 x 470) 5 31 x 31 (787 x 787) - 26 x 26 (660 x 660) 181/2 x 181/2 (470 x 470) 7 35 x 35 (889 x 889) 160 - 180 180 - 200 30 x 30 (762 x 762) 201/2 x 201/2 (521 x 521) 7 39 x 39 (991 x 991) - 220 - 240 34 x 34 (864 x 864) 261/2 x 261/2 (673 x 673) 7 43 x 43 (1092 x 1092) - 260 - 300 40 x 40 (1016 x 1016) 321/2 x 321/2 (826 x 826) 9 49 x 49 (1245 x 1245) All dimensions in inches (millimeters). Typical Mounting Fan to Curb Model H-G or H-GB 5/16 inch recommended 1/4 inch fastener minimum See table for fastener quantities H-G Size H-GB Size Fasteners Per Side Total Fasteners 060 - 141 071 - 161 3 12 150 - 180 180 - 300 5 20 Tie downs are not required to meet 150 MPH wind loads for sizes 240 and smaller (Tie downs are included for larger sizes) Model H-GPF or SD Curb Fasteners on each side of the fan are to be installed with one fastener 4 inches (102 mm) from each edge and one fastener centered. The remaining fasteners are to be equally spaced. Fan to curb tie down is not required to meet 150 mph wind loads for sizes 240 and smaller. H-G-060 and 065 - Direct Drive 193/8 (492) H- W.G. *121/8 (308) 12 (305) 17 (432) 5 (127) ® Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) ^Approximate Unit Weight = 18 lb. (8 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-060-E 1/200 1050 H-G-060-G H-G-060-D H-G-065-E H-G-065-G H-G-065-D 1/100 1/60 1/100 1/60 1/30 1300 1550 1050 1300 1550 CFM / Static Pressure in Inches WG 0 0.05 0.1 0.125 0.15 CFM 138 116 90 73 53 0.01 0.2 BHP 0.00 0.00 0.01 0.01 Sones 1.7 1.7 1.7 1.7 1.7 CFM 170 153 135 125 113 85 BHP 0.01 0.01 0.01 0.01 0.01 0.01 0.25 0.3 Sones 2.9 2.8 2.8 2.7 2.7 2.6 CFM 203 188 173 166 158 140 120 92 BHP 0.01 0.01 0.01 0.01 0.02 0.02 0.02 0.2 Sones 4.2 3.9 3.8 3.8 3.8 3.7 3.7 3.6 CFM 187 161 130 110 87 BHP 0.01 0.01 0.01 0.01 0.01 Sones 2.2 2.1 1.9 1.8 1.7 CFM 231 211 189 178 163 130 92 BHP 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.375 Sones 3.2 3.1 3.0 2.9 2.9 2.8 2.7 CFM 276 259 241 232 223 201 176 145 96 BHP 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 Sones 4.9 4.6 4.5 4.5 4.4 4.3 4.3 4.1 4.0 0.4 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 10 H-G-070 and 075 - Direct Drive 193/8 (492) H- W.G. *121/8 (308) 12 (305) 17 (432) 5 (127) ® Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) ^Approximate Unit Weight = 18 lb. (8 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-070-E 1/100 1050 H-G-070-G H-G-070-D H-G-075-E H-G-075-G H-G-075-D 1/60 1/30 1/80 1/50 1/25 1300 1550 1050 1300 1550 CFM / Static Pressure in Inches WG 0 0.05 0.1 0.125 0.15 CFM 253 226 195 179 152 0.01 0.2 0.25 BHP 0.01 0.01 0.01 0.01 Sones 2.7 2.1 1.7 1.5 1.2 CFM 314 292 269 2557 244 214 171 BHP 0.01 0.1 0.02 0.02 0.02 0.02 0.02 0.3 0.375 Sones 4.1 3.7 3.4 3.3 3.2 2.9 2.6 CFM 374 356 337 327 317 297 274 244 190 BHP 0.02 0.02 0.02 0.03 0.03 0.03 0.03 0.03 0.03 Sones 5.6 5.4 5.2 5.2 5.1 4.9 4.7 4.5 4.1 CFM 297 260 222 200 176 BHP 0.01 0.01 0.01 0.01 0.01 Sones 3.6 3.1 2.9 2.8 2.6 CFM 367 338 309 293 277 241 195 BHP 0.02 0.02 0.02 0.02 0.02 0.02 0.02 Sones 4.1 3.9 3.7 3.7 3.7 3.6 3.5 CFM 438 413 389 377 364 337 309 277 214 BHP 0.03 0.03 0.3 0.04 0.04 0.04 0.04 0.04 0.03 Sones 6.1 5.8 5.6 5.4 5.3 5.1 4.9 4.9 4.8 0.4 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 11 H-G-080 and 085 - Direct Drive 213/4 (552) H- W.G. *145/8 (371) 12 (305) 17 (432) 5 (127) ® Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 26 lb. (12 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-080-E 1/40 1050 H-G-080-G H-G-080-D H-G-085-E H-G-085-G H-G-085-D 1/30 1/20 1/40 1/30 1/20 1300 1550 1050 1300 1550 CFM / Static Pressure in Inches WG 0 0.1 0.125 0.15 0.2 0.25 CFM 335 268 249 230 189 134 0.02 0.3 0.375 BHP 0.01 0.02 0.02 0.02 0.02 Sones 3.8 3.7 3.6 3.7 3.9 4.2 CFM 415 361 348 333 303 272 239 174 BHP 0.02 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.5 Sones 5.4 5.4 5.4 5.4 5.4 5.5 5.6 5.9 CFM 495 450 439 427 404 379 354 314 237 BHP 0.04 0.04 0.04 0.05 0.05 0.05 0.05 0.06 0.6 Sones 7.3 7.3 7.3 7.3 7.3 7.2 7.3 7.3 7.6 CFM 398 326 307 286 240 179 BHP 0.01 0.02 0.02 0.02 0.02 0.02 Sones 4.0 3.9 3.9 3.9 4.1 4.3 CFM 493 436 420 405 375 340 302 233 BHP 0.02 0.03 0.03 0.03 0.03 0.04 0.04 0.04 0.625 Sones 5.5 5.3 5.3 5.3 5.3 5.3 5.4 5.5 CFM 588 541 528 515 490 464 439 394 308 168 BHP 0.04 0.04 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.06 Sones 7.6 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.6 8.1 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 12 H-G-090 and 095 - Direct Drive 213/4 (552) H- W.G. *145/8 (371) 12 (305) 17 (432) 5 (127) ® Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) ^Approximate Unit Weight = 26 lb. (12 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-090-E 1/40 1050 H-G-090-G H-G-090-D H-G-095-E H-G-095-G H-G-095-D 1/25 1/15 1/30 1/12 1/8 1300 1550 1050 1300 1550 CFM / Static Pressure in Inches WG 0 0.1 0.125 0.15 0.2 0.25 CFM 520 441 420 398 351 293 0.02 0.3 0.375 BHP 0.01 0.02 0.02 0.02 0.02 Sones 4.0 3.9 3.9 4.0 4.1 4.2 CFM 644 580 565 549 515 478 440 373 BHP 0.03 0.03 0.04 0.04 0.04 0.04 0.04 0.05 0.5 0.625 Sones 5.4 5.4 5.4 5.4 5.4 5.5 5.5 5.6 CFM 768 714 701 688 662 633 605 557 473 338 BHP 0.05 0.05 0.06 0.06 0.06 0.06 0.07 0.07 0.08 0.07 Sones 7.6 7.5 7.5 7.5 7.5 7.4 7.4 7.4 7.4 7.8 CFM 717 606 570 534 468 389 290 BHP 0.03 0.03 0.04 0.04 0.04 0.04 0.03 Sones 5.4 4.5 4.5 4.5 4.4 4.5 4.6 CFM 888 802 780 754 695 640 586 493 184 BHP 0.06 0.06 0.06 0.06 0.07 0.07 0.07 0.07 0.05 Sones 7.6 6.8 6.7 6.6 6.5 6.4 6.4 6.4 6.8 CFM 1059 987 969 950 912 863 814 745 623 474 BHP 0.10 0.10 0.10 0.11 0.11 0.11 0.11 0.12 0.12 0.11 Sones 9.6 9.4 9.3 9.2 9.0 8.8 8.7 8.7 8.7 8.7 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 13 H-G-101 and 121 - Direct Drive 245/8 (625) H- W.G. *20 (508) 12 (305) 19 (483) 5 (127) ® Damper Size = 12 x 12 (304 x 304) Roof Opening = 141/2 x 141/2 (368 x 368) ^Approximate Unit Weight = 43 lb. (20 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-101-C 1/8 860 H-G-101-B H-G-101-A H-G-121-C H-G-121-B H-G-121-A 1/6 1/4 1/8 1/6 1/4 1140 1725 860 1140 1725 CFM / Static Pressure in Inches WG 0 0.1 0.125 CFM 766 625 588 0.03 0.25 0.3 0.375 BHP 0.02 0.03 Sones 4.3 4.2 4.2 CFM 1015 917 893 747 683 569 BHP 0.05 0.06 0.06 0.06 0.06 0.06 0.5 0.625 0.75 Sones 7.1 7.0 7.0 6.8 6.8 6.6 CFM 1536 1470 1454 1374 1340 1277 1181 1086 974 BHP 0.17 0.18 0.19 0.20 0.20 0.20 0.21 0.22 0.22 Sones 12.1 11.9 11.8 11.6 11.5 11.3 11.2 11.3 11.7 CFM 922 767 723 450 BHP 0.03 0.03 0.04 0.04 Sones 5.6 5.2 5.2 5.2 CFM 1222 1107 1078 918 848 734 335 BHP 0.06 0.07 0.07 0.08 0.09 0.09 0.07 1 Sones 8.1 7.9 7.9 7.8 7.8 8.1 9.8 CFM 1849 1772 1753 1659 1621 1560 1453 1341 1223 911 BHP 0.22 0.23 0.24 0.25 0.26 0.27 0.28 0.29 0.3 0.29 Sones 14.1 14.0 13.9 13.8 13.6 13.4 13.4 13.4 13.4 14.1 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 14 H-G-131 and 141 - Direct Drive 287/8 (733) H- W.G. *20 (508) 12 (305) 22 (559) 5 (127) ® Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) ^Approximate Unit Weight = 59 lb. (27 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-131-C 1/8 860 H-G-131-B H-G-131-A H-G-141-C H-G-141-B 1/6 1/2 1/8 1/6 1140 1725 860 1140 CFM / Static Pressure in Inches WG 0 0.1 0.125 0.25 0.3 CFM 1193 1050 1011 771 626 0.055 0.375 0.5 BHP 0.04 0.049 0.051 0.056 Sones 6.5 6.1 6.0 5.9 5.9 CFM 1581 1482 1452 1304 1239 1130 889 BHP 0.094 0.105 0.108 0.12 0.123 0.13 0.129 0.625 0.75 1 Sones 9.9 9.8 9.7 9.4 9.2 9.0 8.8 CFM 2393 2340 2327 2225 2186 2127 2030 1931 1817 1555 BHP 0.325 0.339 0.342 0.366 0.376 0.389 0.407 0.423 0.426 0.453 Sones 19.2 18.9 18.9 18.4 18.4 18.2 18.1 18.1 17.8 17.4 CFM 1376 1205 1161 919 798 489 BHP 0.055 0.064 0.066 0.074 0.074 0.063 Sones 6.8 6.6 6.5 6.4 6.6 8.0 CFM 1824 1701 1667 1498 1425 1314 1113 794 BHP 0.129 0.141 0.144 0.158 0.163 0.17 0.175 0.158 Sones 10.4 10.4 10.3 9.8 9.5 9.1 8.7 8.4 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 15 H-G-150 and 160 - Direct Drive ® 35 /2 (902) 1 *211/8 (537) 5 (127) H- 12 (305) 26 (660) W.G. Model H-G-150 Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) ^Approximate Unit Weight = 59 lb. (27 kg) 351/2 (902) *215/8 (549) 12 (305) 30 (762) 5 (127) Models H-G-160 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 81 lb. (37 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-150-C 1/8 860 H-G-150-B H-G-160-C H-G-160-B 1/4 1/8 1/3 1140 860 1140 CFM / Static Pressure in Inches WG 0 0.1 0.125 0.2 0.25 0.3 0.375 CFM 1772 1598 1553 1415 1304 1194 1005 0.13 .5 .625 .75 1114 BHP 0.09 0.09 0.10 0.12 0.12 0.13 Sones 7.9 7.8 7.8 7.5 7.4 7.5 7.7 CFM 2349 2217 2185 2085 2017 1949 1836 1628 1397 BHP 0.21 0.21 0.21 0.21 0.23 0.25 0.27 0.29 0.29 0.28 Sones 11.7 11.6 11.6 11.3 11.1 11.0 10.9 11.2 11.8 12.8 CFM 2008 1828 1784 1637 1535 1421 1230 0.14 BHP 0.10 0.11 0.12 0.13 0.13 0.13 Sones 8.0 7.7 7.7 7.5 7.4 7.3 7.3 CFM 2662 2521 2489 2392 2319 2245 2135 1933 1697 1411 BHP 0.23 0.25 0.25 0.27 0.28 0.28 0.29 0.31 0.32 0.32 Sones 13.6 13.4 13.4 13.3 13.1 13.1 13.1 12.9 12.7 12.6 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 16 H-G-170 and 180 - Direct Drive ® 351/2 (902) *215/8 (549) 5 (127) H- 12 (305) 30 (762) W.G. Models H-G-170 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 81 lb. (37 kg) 351/2 (902) *223/4 (578) 12 (305) 30 (762) 5 (127) Model H-G-180 Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) ^Approximate Unit Weight = 118 lb. (54 kg) All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number HP (Size) Fan RPM H-G-170-C 1/4 860 H-G-170-B H-G-180-C H-G-180-B 1/2 1/3 3/4 1140 860 1140 CFM / Static Pressure in Inches WG 0 0.1 0.125 0.25 0.3 0.375 0.5 CFM 2572 2379 2330 2077 1961 1782 1416 0.228 0.625 0.75 1 BHP 0.172 0.187 0.191 0.208 0.214 0.223 Sones 9.7 9.6 9.5 9.2 9.1 9.1 9.1 CFM 3409 3263 3227 3043 2969 2857 2647 2428 2181 1457 BHP 0.4 0.421 0.426 0.45 0.46 0.473 0.494 0.514 0.532 0.488 Sones 16.3 16.2 16.2 16.1 16.1 16.1 16.1 16.1 16.1 17.2 CFM 3240 3053 3002 2733 2603 2390 1978 1438 0.316 BHP 0.24 0.262 0.268 0.296 0.306 0.321 0.332 Sones 12.1 12.4 12.4 12.5 12.5 12.3 11.9 11.9 CFM 4295 4156 4121 3933 3855 3731 3509 3241 2971 2246 BHP 0.559 0.589 0.596 0.634 0.649 0.671 0.707 0.74 0.771 0.759 Sones 19.5 19.4 19.4 19.3 19.5 19.7 19.8 20 20 21 ­­­ Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical fan sone levels. 17 H-GB-071 - Belt Drive ® 243/8 (619) H- W.G. his sy stem cur ve *233/4 (603) sele ct t o th e lef 12 (305) 19 (483) 5 (127) t of t 43/8 (111) on ot Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) D All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-071-6 or H-GB-071-4 HP (Size) Fan RPM 1/6 or 1/4 630 738 846 954 1062 1170 1278 1386 1494 1602 1710 18 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 137 0.01 1.3 161 0.01 1.9 184 0.02 2.7 208 0.02 3.5 231 0.03 4.5 255 0.04 5.7 279 0.05 6.7 302 0.07 7.6 326 0.09 8.6 349 0.11 9.8 373 0.13 11.1 0.125 79 0.01 1.4 112 0.01 2.1 144 0.02 2.6 172 0.02 3.6 200 0.03 4.6 227 0.04 5.7 254 0.05 6.7 280 0.07 7.6 305 0.09 8.6 329 0.11 9.7 353 0.13 11.0 0.25 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 0.875 1 1.125 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM =- (RPM/3371) (RPM/3371)33 MAXIMUM MAXIMUM RPM RPM =- 1710 1710 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 2.929 x 2.929 MAXIMUM MAXIMUM MOTOR MOTOR FRAME FRAME SIZE SIZE =- 56 56 95 0.01 2.6 132 0.02 3.4 164 0.03 4.4 196 0.04 5.5 226 0.05 6.5 253 0.07 7.4 280 0.09 8.4 308 0.11 9.6 335 0.13 11.0 76 0.02 3.2 127 0.03 4.2 162 0.04 5.2 195 0.05 6.2 226 0.07 7.2 257 0.09 8.2 286 0.11 9.3 312 0.13 10.6 123 0.04 5.0 164 0.05 6.0 197 0.07 6.9 230 0.09 7.9 262 0.11 9.1 292 0.13 10.3 124 0.05 5.8 169 0.07 6.7 203 0.08 7.6 237 0.10 8.8 269 0.13 10.0 129 0.06 6.5 177 0.08 7.5 212 0.10 8.5 246 0.13 9.8 138 0.07 7.3 186 0.10 8.4 223 0.12 9.5 150 0.09 8.1 198 0.12 9.3 164 0.11 9.1 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-081 - Belt Drive ® 243/8 (619) H- tem c W.G. urve *233/4 (603) e le ft o 12 (305) 19 (483) no ts ele ct t o th 5 (127) f th i s sys 43/8 (111) Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 in. (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-081-6 or H-GB-081-4 HP (Size) Fan RPM 1/6 or 1/4 630 738 864 954 1062 1170 1278 1386 1494 1602 1710 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 316 0.01 2.4 370 0.01 3.1 433 0.02 4.0 478 0.03 4.8 532 0.04 5.9 586 0.05 6.9 640 0.07 7.9 694 0.09 9.1 748 0.11 10.1 802 0.14 11.3 856 0.17 12.5 0.125 207 0.01 2.1 283 0.02 2.8 361 0.02 3.8 413 0.03 4.6 474 0.04 5.7 533 0.06 6.7 592 0.07 7.8 650 0.09 8.9 708 0.12 10.0 765 0.14 11.1 821 0.17 12.3 0.25 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 0.875 1 1.125 MAXIMUM BHP AT A GIVEN RPM = (RPM/2985)3 MAXIMUM RPM = 1710 TIP SPEED (ft/min.) = RPM x 2.929 MAXIMUM MOTOR FRAME SIZE = 56 265 0.02 3.5 341 0.03 4.2 411 0.05 5.3 478 0.06 6.4 543 0.08 7.4 605 0.10 8.6 666 0.12 9.8 725 0.15 10.9 785 0.18 12.1 329 0.04 5.0 419 0.06 6.0 490 0.08 7.0 557 0.10 8.2 623 0.12 9.4 686 0.15 10.5 748 0.18 11.9 317 0.06 5.7 428 0.08 6.7 507 0.10 7.9 577 0.12 8.9 644 0.15 10.1 710 0.19 11.5 320 0.07 6.6 441 0.10 7.6 528 0.13 8.7 602 0.15 9.9 669 0.19 11.2 334 0.09 7.6 457 0.12 8.5 552 0.16 9.6 630 0.19 10.9 357 0.11 8.4 480 0.15 9.5 581 0.19 10.6 388 0.14 9.3 511 0.18 10.5 424 0.17 10.3 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 19 H-GB-091 - Belt Drive ® 243/8 (619) H- W.G. ystem curve *233/4 (603) t to the le ft of 12 (305) 19 (483) 5 (127) this s 43/8 (111) no ts ele c Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 in. (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 58 lb. (26 kg) o D All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-091-4 HP (Size) Fan RPM 1/4 630 738 864 954 1062 1170 1278 1386 1494 1602 1710 20 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 477 0.01 2.9 559 0.02 3.7 655 0.03 4.9 723 0.04 5.9 805 0.05 7.2 886 0.07 8.7 968 0.09 9.5 1050 0.12 10.3 1132 0.15 11.2 1214 0.18 12.3 1296 0.22 13.4 0.125 309 0.01 3.0 421 0.02 3.6 539 0.03 4.8 619 0.04 5.7 711 0.06 7.0 802 0.08 8.4 891 0.10 9.3 979 0.12 10.1 1066 0.15 11.1 1152 0.19 12.1 1238 0.23 13.3 0.25 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 0.875 1 1.125 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM =- (RPM/3371) (RPM/2703)33 MAXIMUM MAXIMUM RPM RPM =- 1710 1710 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 2.929 x 2.929 MAXIMUM MAXIMUM MOTOR MOTOR FRAME FRAME SIZE SIZE =- 56 56 405 0.03 4.5 506 0.04 5.3 613 0.06 6.6 715 0.08 8.0 813 0.10 8.9 907 0.13 9.9 999 0.16 10.9 1090 0.19 12.0 1180 0.23 13.2 313 0.04 5.1 502 0.06 6.2 621 0.08 7.5 729 0.10 8.5 832 0.13 9.5 932 0.16 10.6 1028 0.20 11.8 1122 0.24 13.0 500 0.08 7.1 639 0.11 8.1 752 0.13 9.1 860 0.17 10.2 962 0.20 11.4 1062 0.24 12.7 516 0.10 7.8 666 0.14 8.8 785 0.17 9.9 894 0.20 11.1 999 0.25 12.4 545 0.13 8.5 698 0.17 9.6 823 0.21 10.8 934 0.25 12.1 584 0.16 9.3 738 0.21 10.5 867 0.25 11.8 631 0.20 10.2 785 0.25 11.6 685 0.24 11.2 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-101 - Belt Drive ® 243/8 (619) H- ystem W.G. curve *233/4 (603) ct t o th e le 12 (305) 19 (483) ts ele 5 (127) f t of this s 43/8 (111) no Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 63 lb. (29 kg) o D All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-101-4 HP (Size) Fan RPM 1/4 830 930 1030 1130 1230 1330 1430 1530 1635 H-GB-101-3 1/3 1718 1800 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 703 0.03 4.5 788 0.04 5.1 873 0.05 5.7 958 0.07 6.5 1042 0.09 7.3 1127 0.12 8.3 1212 0.14 9.1 1297 0.18 10.0 1386 0.22 11.1 1456 0.25 12.1 1526 0.29 13.2 0.125 594 0.03 3.5 688 0.04 4.3 781 0.06 5.1 873 0.08 5.9 965 0.10 6.8 1055 0.12 7.8 1144 0.15 8.8 1233 0.18 9.7 1326 0.22 10.8 1399 0.26 11.7 1471 0.30 12.8 0.25 420 0.03 2.6 572 0.05 3.7 688 0.06 4.7 795 0.08 5.6 894 0.11 6.5 987 0.13 7.6 1080 0.16 8.5 1173 0.19 9.5 1269 0.23 10.4 1345 0.27 11.3 1419 0.30 12.5 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 0.875 1 1.25 MAXIMUM BHP AT A GIVEN RPM = (RPM/2593)3 MAXIMUM RPM = 1800 TIP SPEED (ft/min.) = RPM x 2.913 MAXIMUM MOTOR FRAME SIZE = 56 539 0.06 3.8 690 0.08 5 807 0.11 6.2 917 0.14 7.4 1021 0.17 8.2 1117 0.20 9.1 1215 0.24 10.2 1291 0.28 11.1 1368 0.31 12.3 420 0.07 3.6 693 0.11 5.5 827 0.14 6.9 943 0.17 7.8 1053 0.21 8.6 1162 0.25 9.8 1244 0.29 10.8 1321 0.33 12.2 696 0.13 6.4 851 0.17 7.3 975 0.21 8.2 1095 0.25 9.3 1185 0.29 10.2 1270 0.34 11.3 715 0.16 6.6 883 0.21 7.8 1020 0.25 8.9 1118 0.29 9.8 1209 0.34 10.8 744 0.19 7.1 929 0.25 8.4 1043 0.29 9.4 1142 0.34 10.6 793 0.24 7.8 943 0.29 8.9 1065 0.34 10.1 793 0.30 9.3 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 21 H-GB-101HP - Belt Drive ® 243/8 (619) H- t of t his sy stem W.G. curve *233/4 (603) 43/8 (111) lec t 5 (127) to t he le f 12 (305) 19 (483) no t se Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 63 lb. (29 kg) o D All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-101HP-4 HP (Size) Fan RPM 1/4 1300 1445 1590 1735 1880 2025 H-GB-101HP-3 1/3 2137 2229 H-GB-101HP-5 1/2 2336 2443 2550 22 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 571 0.06 6.6 635 0.08 8.4 699 0.10 10.4 762 0.13 11.5 826 0.17 12.7 890 0.21 14.2 939 0.25 15.4 979 0.29 15.8 1026 0.33 16.4 1073 0.38 17.3 1120 0.43 18.2 0.25 477 0.06 5.7 553 0.09 7.5 626 0.11 9.5 697 0.15 10.8 767 0.18 12.2 836 0.23 13.6 889 0.26 14.8 931 0.30 15.4 981 0.34 16.0 1030 0.39 16.9 1078 0.44 17.9 0.5 342 0.07 5.3 449 0.09 7.0 537 0.12 9.1 619 0.15 10.7 697 0.20 11.9 772 0.24 13.3 830 0.28 14.4 875 0.31 14.8 928 0.36 15.4 981 0.41 16.4 1032 0.46 17.4 CFM / Static Pressure in Inches WG 0.75 1 1.25 1.5 243 0.08 6.3 417 0.12 8.3 527 0.16 10.3 618 0.20 12 702 0.24 13.2 765 0.28 14.2 814 0.32 14.5 871 0.37 14.9 927 0.42 16.0 982 0.48 17.2 1.75 2 2.25 MAXIMUM BHP AT A GIVEN RPM = (RPM/3165)3 MAXIMUM RPM = 2550 TIP SPEED (ft/min.) = RPM x 2.978 MAXIMUM MOTOR FRAME SIZE = 56 376 0.15 10.2 518 0.21 11.4 622 0.26 12.6 693 0.30 13.4 748 0.33 14.1 809 0.37 14.7 869 0.42 928 0.48 16.3 337 0.18 11.9 515 0.25 12 607 0.30 13.1 674 0.35 13.7 742 0.39 14.0 807 0.44 14.9 869 0.49 16.1 313 0.22 11.4 474 0.28 12.1 574 0.33 13.2 661 0.40 14.1 739 0.46 14.5 807 0.51 15.1 406 0.31 543 0.38 13.5 649 0.44 14.7 735 0.52 15.6 358 0.34 13.6 519 0.42 15.0 639 0.50 16.2 497 0.47 17.2 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-121 - Belt Drive ® 243/8 (619) H- is s yst em cur ve W.G. *233/4 (603) 43/8 (111) to to th e lef 5 (127) f th 12 (305) 19 (483) ct Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 66 lb. (30 kg) s ot e n Do le All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-121-4 HP (Size) Fan RPM 1/4 595 728 861 994 1127 1260 1395 H-GB-121-3 1/3 1473 1550 H-GB-121-5 1/2 1638 1725 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 722 0.02 3.3 883 0.03 4.2 1044 0.05 5.4 1206 0.08 6.7 1367 0.11 8.2 1528 0.16 10.1 1692 0.21 12.5 1787 0.25 13.5 1880 0.30 14.6 1987 0.35 16.0 2093 0.40 17.4 0.125 542 0.02 3.4 747 0.04 4.3 933 0.06 5.5 1111 0.09 6.7 1284 0.12 8.2 1454 0.17 10.1 1625 0.23 12.4 1723 0.27 13.4 1820 0.31 14.5 1930 0.36 15.8 2038 0.42 17.2 0.25 543 0.04 4.2 798 0.06 5.2 1004 0.09 6.6 1195 0.13 8.2 1377 0.18 10.0 1557 0.24 12.3 1659 0.28 13.3 1759 0.32 14.3 1872 0.38 15.6 1984 0.44 17.0 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 1 1.25 1.5 MAXIMUM BHP AT A GIVEN RPM = (RPM/2170)3 MAXIMUM RPM = 1725 TIP SPEED (ft/min.) = RPM x 3.420 MAXIMUM MOTOR FRAME SIZE = 56 584 0.06 5.2 872 0.10 6.4 1092 0.14 7.9 1292 0.19 9.9 1484 0.25 12.2 1591 0.29 13.1 1696 0.33 14.2 1814 0.39 15.5 1928 0.45 16.8 673 0.09 6.3 969 0.14 7.8 1196 0.19 9.6 1404 0.26 12.0 1518 0.30 12.9 1629 0.34 14.0 1751 0.40 15.3 1871 0.46 16.7 799 0.13 7.7 1084 0.19 9.5 1315 0.26 11.7 1438 0.31 12.7 1555 0.35 13.8 1684 0.41 15.1 1810 0.47 16.4 938 0.19 9.3 1214 0.26 11.5 1352 0.31 12.4 1475 0.36 13.5 1613 0.42 14.9 1743 0.48 16.2 907 0.25 11.3 1127 0.30 12.0 1289 0.36 12.9 1452 0.43 14.0 1600 0.50 15.5 974 0.33 12.4 1238 0.42 13.5 1426 0.50 14.9 1180 0.48 14.0 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 23 H-GB-131 - Belt Drive ® 283/8 (721) H- W.G. *233/4 (603) 12 (305) ef t of 19 (483) th el 5 (127) th i ss yst em cur ve 4 (102) tt o Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 in. (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 67 lb. (30 kg) s ot Do n c ele All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-131-4 HP (Size) Fan RPM 1/4 595 700 800 900 1000 1100 1200 1315 H-GB-131-3 1/3 1440 H-GB-131-5 1/2 1563 1685 24 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 844 0.02 4.5 993 0.03 5.2 1135 0.05 6.0 1277 0.07 7.0 1419 0.10 8.1 1516 0.13 9.5 1703 0.17 11.1 1866 0.22 13.2 2044 0.294 15.0 2218 0.375 16.0 2391 0.47 16.9 0.125 655 0.02 4.6 845 0.04 5.2 1012 0.06 6.0 1169 0.08 6.9 1223 0.11 8.0 1475 0.14 9.2 1624 0.18 10.8 1794 0.23 12.8 1978 0.306 15.0 2158 0.389 15.8 2335 0.485 16.6 0.25 585 0.04 5.0 843 0.06 5.7 1039 0.08 6.6 1213 0.11 7.7 1381 0.15 9.0 1539 0.19 10.5 1718 0.24 12.5 1911 0.318 15.1 2097 0.402 15.6 2279 0.499 16.3 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 1 1.25 1.5 MAXIMUM BHP AT A GIVEN RPM = (RPM/2047)3 MAXIMUM RPM = 1685 TIP SPEED (ft/min.) = RPM x 3.436 MAXIMUM MOTOR FRAME SIZE = 56 845 0.08 6.3 1075 0.12 7.4 1268 0.15 8.6 1443 0.20 10.1 1637 0.25 12.1 1838 0.327 15.1 2031 0.413 15.5 2219 0.512 16.0 867 0.11 7.0 1124 0.16 8.3 1330 0.20 9.7 1545 0.26 11.7 1759 0.336 14.5 1964 0.424 15.2 2158 0.523 15.7 898 0.15 7.9 1191 0.20 9.4 1435 0.26 11.2 1674 0.344 13.9 1887 0.432 14.8 2093 0.534 15.4 964 0.19 8.8 1305 0.26 10.9 1571 0.347 13.4 1807 0.44 14.3 2020 0.543 15.1 1299 0.342 12.5 1606 0.445 13.6 1857 0.555 14.5 1300 0.427 12.8 1654 0.557 13.9 1312 0.522 13.5 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-141 - Belt Drive ® 283/8 (721) H- curv e W.G. *233/4 (603) to t he left o f th 12 (305) 22 (559) 5 (127) is s y stem 4 (102) se le ct Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 83 lb. (38 kg) t no Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-141-4 HP (Size) Fan RPM 1/4 525 663 801 939 1075 H-GB-141-3 1/3 1170 H-GB-141-5 1/2 1265 1360 H-GB-141-7 3/4 1453 1545 H-GB-141-10 1 1705 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 974 0.03 4.4 1230 0.06 5.3 1486 0.10 6.5 1742 0.16 7.9 1994 0.24 10.0 2170 0.31 11.4 2347 0.39 12.9 2523 0.48 14.6 2695 0.59 16.2 2866 0.71 17.6 3163 0.95 20 0.125 709 0.03 4.2 1046 0.06 5.5 1337 0.11 6.6 1614 0.17 7.8 1882 0.25 9.9 2067 0.32 11.3 2250 0.40 12.7 2433 0.50 14.3 2612 0.60 15.9 2787 0.72 18.0 3091 0.97 20 0.25 732 0.06 4.4 1161 0.11 6.1 1482 0.17 7.5 1771 0.26 9.4 1966 0.33 10.8 2158 0.41 12.3 2347 0.51 13.9 2530 0.62 15.6 2710 0.74 17.4 3020 0.98 20 CFM / Static Pressure in Inches WG 0.375 0.5 0.75 1 1.25 1.5 1.75 MAXIMUM BHP AT A GIVEN RPM = (RPM/1676)3 MAXIMUM RPM = 1705 TIP SPEED (ft/min.) = RPM x 3.829 MAXIMUM MOTOR FRAME SIZE = 145T 850 0.10 5.3 1313 0.18 7.0 1647 0.26 8.9 1859 0.33 10.3 2062 0.42 11.9 2259 0.52 13.5 2449 0.63 15.3 2634 0.75 17.1 2952 1.00 19.6 1040 0.16 6.4 1490 0.26 8.4 1734 0.34 9.9 1955 0.42 11.4 2166 0.52 13.1 2365 0.64 14.8 2556 0.76 16.8 2883 1.02 19.2 1356 0.32 8.7 1677 0.42 10.4 1943 0.53 12.2 2173 0.64 13.9 2384 0.77 14.9 2739 1.03 18.1 1048 0.35 8.8 1602 0.51 11.0 1914 0.64 13.0 2177 0.78 14.7 2574 1.03 16.9 1513 0.60 11.8 1890 0.75 14.7 2370 1.05 16.7 2120 1.02 16.6 1731 0.96 16.4 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 25 H-GB-141HP - Belt Drive ® 283/8 (721) H- this syste m W.G. curve *233/4 (603) 4 (102) e le ft of sel ect to t h 5 (127) 12 (305) 22 (559) no t Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 83 lb. (38 kg) Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-141HP-4 HP (Size) Fan RPM 1/4 905 1054 1203 1352 1500 H-GB-141HP-3 1/3 1655 H-GB-141HP-5 1/2 1737 1818 1900 H-GB-141HP-7 3/4 2035 2170 26 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 270 0.05 5.5 537 0.09 6.7 714 0.13 8.4 870 0.18 10.9 1009 0.24 13.1 1151 0.32 15.0 1224 0.37 16.4 1295 0.42 17.9 1366 0.47 19.0 1483 0.57 21 1598 0.68 22 0.75 1 CFM / Static Pressure in Inches WG 1.25 1.5 1.75 2 2.25 2.5 2.75 MAXIMUM BHP AT A GIVEN RPM = (RPM/2351)3 MAXIMUM RPM = 2170 TIP SPEED (ft/min.) = RPM x 3.829 MAXIMUM MOTOR FRAME SIZE = 145T 527 0.13 8.3 740 0.19 10.3 903 0.26 12.3 1064 0.34 14.1 1143 0.38 15.6 1218 0.44 17.3 1294 0.49 18.4 1417 0.60 20 1536 0.71 22 547 0.19 10.4 774 0.26 12.2 959 0.35 13.3 1048 0.40 14.9 1133 0.45 16.8 1218 0.51 18.0 1347 0.62 19.6 1472 0.73 21 592 0.25 12.4 833 0.35 13.1 946 0.40 14.4 1037 0.46 15.9 1127 0.53 17.4 1269 0.63 19.1 1407 0.76 21 668 0.34 13.6 802 0.40 14.4 920 0.46 15.7 1033 0.53 16.8 1184 0.65 18.6 1328 0.77 21 619 0.38 15.0 773 0.45 16.0 901 0.52 16.7 1095 0.65 18.4 1248 0.78 21 561 0.42 16.7 753 0.51 17.0 969 0.64 18.1 1163 0.79 21 832 0.63 18.2 1045 0.78 20 633 0.59 18.5 919 0.77 19.7 757 0.74 19.8 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-161 - Belt Drive ® 283/8 (721) H- th i s sy ste mc ur v e W.G. *233/4 (603) 4 (102) th e lef t 5 (127) of 12 (305) 22 (559) tt o Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 89 lb. (40 kg) le c se ot n Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-161-4 HP (Size) Fan RPM 1/4 478 575 670 765 865 H-GB-161-3 1/3 945 H-GB-161-5 1/2 1023 1100 H-GB-161-7 3/4 1175 1250 H-GB-161-10 1 1375 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 1412 0.40 4.7 1698 0.07 5.7 1979 0.11 7.0 2260 0.16 8.6 2555 0.24 10.6 2791 0.31 12.6 3022 0.39 14.0 3249 0.49 15.3 3471 0.59 16.5 3692 0.71 17.9 4062 0.95 21 0.125 1030 0.04 4.5 1399 0.08 5.6 1727 0.12 6.7 2040 0.17 8.2 2360 0.25 10.1 2612 0.32 12.0 2856 0.41 13.4 3095 0.50 14.7 3326 0.61 16.0 3557 0.73 17.4 3938 0.97 20 0.25 937 0.07 5.3 1429 0.12 6.5 1802 0.18 8.0 2162 0.26 9.7 2434 0.33 11.5 2693 0.42 12.8 2943 0.52 14.1 3184 0.62 15.5 3422 0.75 17.0 3815 0.99 19.6 CFM / Static Pressure in Inches WG 0.375 0.5 0.75 0.875 1 1.25 1.5 MAXIMUM BHP AT A GIVEN RPM = (RPM/1355)3 MAXIMUM RPM = 1375 TIP SPEED (ft/min.) = RPM x 4.352 MAXIMUM MOTOR FRAME SIZE = 145T 1494 0.18 7.5 1933 0.26 9.4 2236 0.34 11.2 2520 0.43 12.5 2787 0.53 13.8 3040 0.64 15.1 3289 0.76 16.6 3694 1.01 19.2 1624 0.25 8.8 2010 0.34 10.7 2327 0.43 12.1 2615 0.53 13.5 2888 0.65 14.8 3149 0.77 16.3 3571 1.02 18.9 1785 0.40 11.0 2198 0.52 12.5 2541 0.65 14.0 2838 0.79 15.6 3304 1.04 18.4 1900 0.50 12.0 2313 0.64 13.6 2658 0.78 15.2 3161 1.05 18.0 2025 0.61 13.0 2444 0.76 14.9 3007 1.04 17.6 2609 1.01 17.2 2073 0.93 15.4 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 27 H-GB-161HP - Belt Drive ® 283/8 (721) H- syste m W.G. curve *233/4 (603) ct t o th e lef 12 (305) 22 (559) sel e 5 (127) t of this 4 (102) o no t Damper Size = 16 x 16 (406 x 406) Roof Opening = 181/2 x 181/2 (470 x 470) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 89 lb. (40 kg) D All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-161HP-4 HP (Size) Fan RPM 1/4 825 960 1095 H-GB-161HP-3 1/3 1210 H-GB-161HP-5 1/2 1270 1330 1390 H-GB-161HP-7 3/4 1485 1580 H-GB-161HP-10 1 1660 1740 28 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 702 0.11 6.5 1093 0.18 7.7 1380 0.26 9.0 1606 0.34 10.6 1718 0.39 11.4 1829 0.44 12.3 1938 0.50 13.3 2109 0.60 14.9 2275 0.72 16.7 2414 0.82 18.3 2551 0.94 20 0.625 919 0.17 7.6 1271 0.26 9.0 1514 0.35 10.3 1636 0.40 11.2 1753 0.45 12.1 1865 0.51 13.0 2041 0.61 14.7 2214 0.73 16.7 2357 0.84 18.8 2497 0.96 21 0.75 585 0.15 8.0 1139 0.26 8.9 1416 0.35 10.4 1545 0.40 11.1 1668 0.46 11.9 1789 0.52 12.8 1973 0.63 14.4 2150 0.75 16.4 2297 0.85 18.3 2442 0.97 21 CFM / Static Pressure in Inches WG 1 1.25 1.5 1.75 2 2.25 2.5 MAXIMUM BHP AT A GIVEN RPM = (RPM/1708)3 MAXIMUM RPM = 1740 TIP SPEED (ft/min.) = RPM x 4.352 MAXIMUM MOTOR FRAME SIZE = 145T 589 0.21 9.5 1149 0.34 10.3 1333 0.41 11.1 1483 0.47 12.1 1619 0.53 12.7 1822 0.64 13.8 2016 0.77 15.5 2175 0.89 16.7 2325 1.01 18.4 949 0.37 11.4 1204 0.45 12.0 1399 0.53 12.7 1654 0.65 13.7 1868 0.77 14.7 2037 0.89 16.2 2200 1.03 17.5 1032 0.48 13.1 1416 0.63 14.0 1704 0.791 14.8 1887 0.91 15.8 2066 1.03 17.2 1012 0.57 14.7 1447 0.75 15.4 1702 0.90 15.8 1917 1.05 16.8 1034 0.67 16.6 1441 0.86 17.1 1714 1.03 17.2 996 0.75 20 1452 0.98 19.2 987 0.85 28 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-180 - Belt Drive ® 351/2 (902) H- cur ve W.G. *28 (711) he lef to f th is s 12 (305) 30 (762) to t 5 (127) yste m 51/2 (140) el ec t Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 125 lb. (57 kg) n Do ot s All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-180-4 HP (Size) Fan RPM 1/4 495 730 H-GB-180-3 1/3 810 H-GB-180-5 1/2 875 940 H-GB-180-7 3/4 1055 H-GB-180-10 1 1120 1185 H-GB-180-15 11/2 1260 1335 H-GB-180-20 2 1460 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 1925 0.07 4.3 2839 0.21 7.4 3150 0.29 8.8 3402 0.37 10.5 3655 0.46 12.7 4102 0.65 16.2 4355 0.77 17.5 4608 0.91 19.0 4899 1.10 21 5191 1.31 22 5677 1.71 26 0.125 1646 0.08 4.7 2668 0.23 8.7 2997 0.31 9.9 3263 0.38 11.1 3527 0.47 12.8 3990 0.67 15.7 4249 0.79 16.9 4508 0.94 18.4 4805 1.12 19.9 5102 1.33 22 5596 1.74 25 0.25 1150 0.08 4.1 2469 0.27 7.2 2832 0.33 8.7 3113 0.41 10.2 3388 0.49 12.0 3867 0.68 14.9 4134 0.81 16.4 4401 0.96 17.8 4706 1.15 19.3 5010 1.36 21 5514 1.77 24 CFM / Static Pressure in Inches WG 0.5 0.75 1 1.25 1882 0.25 6.7 2375 0.35 8.2 2728 0.44 9.4 3052 0.54 11.1 3596 0.74 14.0 3891 0.88 15.5 4179 1.03 17.1 4498 1.21 18.8 4814 1.41 21 5336 1.81 24 1.5 1.75 2 MAXIMUM BHP AT A GIVEN RPM = (RPM/1149)3 MAXIMUM RPM = 1460 TIP SPEED (ft/min.) = RPM x 4.843 MAXIMUM MOTOR FRAME SIZE = 184T 2144 0.43 8.5 2601 0.54 10.3 3252 0.77 12.9 3587 0.92 14.5 3900 1.07 16.2 4256 1.27 18.0 4599 1.49 19.9 5155 1.93 23 2811 0.77 12.4 3217 0.93 13.8 3575 1.10 15.4 3977 1.32 17.3 4344 1.54 19.2 4938 1.97 23 2686 0.89 13.0 3178 1.09 14.7 3641 1.32 16.8 4052 1.57 18.7 4699 2.03 22 2499 0.99 13.7 3223 1.29 16.1 3713 1.56 18.2 4426 2.05 22 3262 1.51 17.6 4123 2.05 22 3765 2.02 21 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 29 H-GB-180HP - Belt Drive ® 351/2 (902) H- urv e W.G. *28 (711) f th is s lef to 12 (305) 30 (762) to the 5 (127) yste mc 51/2 (140) ele ct Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 125 lb. (57 kg) Do ts no All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-180HP-4 HP (Size) Fan RPM 1/4 795 845 H-GB-180HP-3 1/3 935 H-GB-180HP-5 1/2 1075 H-GB-180HP-7 3/4 1150 1225 H-GB-180HP-10 1 1350 H-GB-180HP-15 11/2 1445 1540 H-GB-180HP-20 2 1620 1700 30 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 1547 0.22 8.6 1759 0.26 9.1 2114 0.35 10.3 2601 0.51 12.9 2847 0.61 14.6 3088 0.73 16.3 3485 0.96 19.5 3782 1.16 22 4076 1.39 25 4319 1.60 27 4560 1.84 30 0.75 1 CFM / Static Pressure in Inches WG 1.25 1.5 1.75 2 2.25 2.5 2.75 MAXIMUM BHP AT A GIVEN RPM = (RPM/1325)3 MAXIMUM RPM = 1700 TIP SPEED (ft/min.) = RPM x 4.843 MAXIMUM MOTOR FRAME SIZE = 184T 1686 0.35 9.6 2316 0.53 12.1 2607 0.64 13.1 2880 0.77 14.7 3296 1.00 17.6 3604 1.21 20 3909 1.44 22 4163 1.66 25 4414 1.90 27 1920 0.52 11.6 2298 0.65 12.6 2610 0.78 13.9 3095 1.04 16.4 3428 1.25 18.8 3744 1.49 21 4005 1.71 24 4263 1.96 26 1811 0.62 12.3 2277 0.78 13.3 2840 1.05 15.8 3213 1.28 17.8 3576 1.53 20 3848 1.76 23 4114 2.01 25 1711 0.72 13.2 2540 1.05 15.0 2969 1.29 17.3 3353 1.55 19.6 3663 1.79 22 3964 2.06 24 2059 0.99 15.1 2670 1.28 16.4 3119 1.56 18.9 3450 1.81 21 3764 2.08 23 2216 1.21 16.6 2827 1.55 18.1 3223 1.82 20 3560 2.10 22 2407 1.48 18.3 2923 1.80 19.7 3340 2.11 22 2512 1.72 19.8 3037 2.07 21 2642 1.99 21 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-200 - Belt Drive ® 351/2 (902) H- curv e W.G. *28 (711) the left of t h 12 (305) 30 (762) t to 5 (127) is sy stem 51/2 (140) ts ele c Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 138 lb. (63 kg) Do no All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-200-4 HP (Size) Fan RPM 1/4 440 600 H-GB-200-3 1/3 665 H-GB-200-5 1/2 718 770 H-GB-200-7 3/4 860 H-GB-200-10 1 965 H-GB-200-15 11/2 1028 1090 H-GB-200-20 2 1145 1200 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 2435 0.10 6.5 3320 0.25 8.5 3680 0.34 9.6 3973 0.43 10.8 4261 0.53 12.1 4759 0.73 14.1 5340 1.03 16.7 5689 1.25 18.5 6032 1.49 20 6336 1.73 22 6640 1.99 24 0.125 1976 0.10 5.8 2984 0.26 7.9 3378 0.34 9.0 3700 0.43 10.0 4013 0.53 11.0 4548 0.74 13.3 5158 1.04 16.0 5517 1.26 17.8 5870 1.50 19.6 6182 1.74 21 6494 2.00 23 0.25 2637 0.26 7.3 3085 0.36 8.5 3422 0.45 9.6 3744 0.55 10.7 4289 0.75 12.9 4927 1.05 15.4 5309 1.27 17.2 5682 1.51 18.9 6010 1.75 21 6336 2.01 23 CFM / Static Pressure in Inches WG 0.375 0.5 0.75 1 2089 0.25 6.1 2706 0.35 7.7 3109 0.45 9.0 3477 0.55 10.2 4068 0.77 12.4 4720 1.08 15.0 5101 1.29 16.8 5473 1.52 18.4 5809 1.76 20 6145 2.02 22 1.25 1.5 1.75 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM == (RPM/3371) (RPM/938)33 MAXIMUM RPM = 1200 1710 TIP SPEED TIP SPEED (ft/min.) = RPM = RPM x 2.929 x 5.596 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE==184T 56 2087 0.33 6.7 2684 0.44 8.3 3141 0.55 9.8 3811 0.77 11.8 4520 1.09 14.5 4918 1.31 16.4 5301 1.56 18.1 5637 1.79 19.8 5969 2.04 22 3085 0.74 11.1 4015 1.08 13.7 4488 1.32 15.6 4925 1.56 17.5 5299 1.81 19.2 5651 2.09 21 3240 1.02 13.0 3911 1.29 14.7 4450 1.56 16.8 4870 1.82 18.7 5274 2.09 21 2941 1.14 14.6 3751 1.48 15.8 4333 1.77 17.7 4829 2.08 19.9 3517 1.64 16.6 4177 1.96 18.6 3077 1.69 16.7 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 31 H-GB-200HP - Belt Drive ® 351/2 (902) H- this syste m W.G. curve *28 (711) 51/2 (140) ft of e le ct t o th 5 (127) 12 (305) 30 (762) no ts ele Damper Size = 18 x 18 (457 x 457) Roof Opening = 201/2 x 201/2 (521 x 521) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 138 lb. (63 kg) Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-200HP-5 HP (Size) Fan RPM 1/2 740 895 H-GB-200HP-7 3/4 958 1020 H-GB-200HP-10 1 1125 H-GB-200HP-15 11/2 1205 1285 H-GB-200HP-20 2 1350 1415 H-GB-200HP-30 3 1520 1625 32 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 1961 0.30 8.7 2809 0.52 11.4 3116 0.63 12.8 3409 0.75 14.1 3885 0.99 16.9 4229 1.19 18.8 4569 1.43 21 4843 1.65 23 5114 1.88 24 5550 2.31 27 5982 2.80 32 0.75 2331 0.53 10.9 2715 0.65 12.1 3050 0.77 13.6 3584 1.02 16.4 3967 1.24 17.9 4343 1.49 20 4638 1.71 22 4919 1.95 24 5368 2.38 27 5812 2.88 31 1 1424 0.45 10.3 2153 0.63 11.6 2602 0.78 13.1 3243 1.04 15.5 3663 1.27 17.2 4070 1.52 19.1 4384 1.75 21 4692 2.00 23 5182 2.45 27 5642 2.95 31 CFM / Static Pressure in Inches WG 1.25 1.5 2 2.5 2.75 3 3.25 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM =- (RPM/3371) (RPM/1106)33 MAXIMUM MAXIMUM RPM RPM =- 1710 1625 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 2.929 x 5.596 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE=-184T 56 1857 0.71 12.6 2804 1.04 15.3 3314 1.29 16.5 3770 1.55 18.1 4109 1.78 19.8 4442 2.04 22 4952 2.50 26 5448 3.02 29 2136 0.97 15.2 2884 1.27 16.4 3416 1.57 17.8 3811 1.81 19.3 4169 2.07 21 4713 2.53 24 5233 3.06 28 2278 1.40 18.9 2996 1.76 19.1 3492 2.07 19.7 4166 2.58 23 4767 3.13 27 2250 1.78 23 3458 2.53 22 4196 3.16 25 2850 2.38 22 3859 3.12 24 2046 2.06 22 3377 3.01 23 2725 2.76 22 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-220 - Belt Drive ® 423/4 (1086) H- ur v e W.G. *311/2 (800) tt ot he l ef t of thi s 12 (305) 34 (864) 5 (127) sys tem c 53/4 (146) le c Damper Size = 24 x 24 (610 x 610) Roof Opening = 261/2 x 261/2 (673 x 673) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 158 lb. (72 kg) n Do se ot All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-220-4 HP (Size) Fan RPM 1/4 425 465 500 H-GB-220-3 1/3 550 H-GB-220-5 1/2 640 H-GB-220-7 3/4 710 H-GB-220-10 1 755 800 H-GB-220-15 ­11/2 848 895 H-GB-220-20 2 985 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 3230 0.14 7.4 3533 0.18 8.1 3799 0.23 8.8 4179 0.30 10.0 4863 0.48 13.0 5395 0.65 15.0 5737 0.79 15.7 6079 0.93 16.6 6444 1.11 17.8 6801 1.31 19.4 7485 1.74 23 0.125 2879 0.16 7.2 3219 0.20 7.8 3512 0.25 8.4 3924 0.32 9.6 4654 0.50 12.8 5206 0.68 14.9 5559 0.82 15.6 5911 0.97 16.4 6286 1.15 17.5 6651 1.34 19.1 7349 1.78 23 0.25 2296 0.16 6.9 2758 0.21 7.4 3132 0.26 7.9 3629 0.34 8.9 4403 0.53 12.1 4990 0.71 14.4 5362 0.84 15.2 5732 1.00 16.1 6122 1.18 17.2 6501 1.38 18.8 7212 1.82 23 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 1951 0.19 7.0 2542 0.26 7.5 3158 0.35 8.4 4120 0.54 11.2 4762 0.73 13.6 5148 0.87 14.6 5530 1.02 15.6 5932 1.21 16.9 6323 1.41 18.5 7062 1.86 22 1 1.25 1.5 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM == (RPM/3371) (RPM/782)33 MAXIMUM MAXIMUM RPM RPM == 1710 985 TIP SPEED TIP SPEED (ft/min.) = RPM = RPM x 2.929 x 6.283 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE==184T 56 2526 0.33 8.0 3702 0.55 10.5 4459 0.74 12.8 4920 0.89 14.0 5326 1.05 15.2 5741 1.23 16.5 6142 1.44 18.2 6898 1.89 22 3208 0.54 9.7 4077 0.75 12.1 4579 0.90 13.4 5049 1.06 14.6 5540 1.26 16.2 5960 1.47 18.0 6734 1.92 22 3633 0.74 11.2 4206 0.90 12.7 4716 1.07 14.2 5236 1.27 15.7 5723 1.49 17.6 6568 1.95 22 3095 0.82 11.2 3929 1.05 12.5 4566 1.27 14.5 5122 1.50 16.9 6107 1.99 21 3542 1.17 13.4 4401 1.47 15.5 5548 2.00 20 4883 1.96 19.0 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 33 H-GB-220HP - Belt Drive ® 423/4 (1086) H- to the left o f th 12 (305) 34 (864) 5 (127) is sy stem 53/4 (146) curv e W.G. *311/2 (800) ot se lec t Damper Size = 24 x 24 (610 x 610) Roof Opening = 261/2 x 261/2 (673 x 673) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 158 lb. (72 kg) n Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-220HP-5 HP (Size) Fan RPM 1/2 650 680 H-GB-220HP-7 3/4 728 775 H-GB-220HP-10 1 850 H-GB-220HP-15 11/2 913 975 H-GB-220HP-20 2 1025 1075 H-GB-220HP-30 3 1127 1230 34 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 2952 0.47 8.9 3215 0.53 9.4 3614 0.65 10.6 3973 0.77 12.0 4532 1.00 15.0 4975 1.22 16.7 5400 1.46 18.7 5740 1.68 21 6076 1.93 23 6422 2.20 24 7100 2.82 28 0.625 2555 0.46 8.5 2871 0.53 9.2 3312 0.65 10.3 3719 0.79 11.5 4317 1.02 13.8 4791 1.25 16.0 5245 1.50 18.2 5591 1.72 20 5935 1.97 22 6289 2.24 24 6981 2.87 27 0.75 1892 0.42 8.3 2440 0.52 8.9 2974 0.65 9.9 3424 0.79 11.1 4083 1.04 13.5 4590 1.27 15.3 5060 1.53 17.5 5432 1.76 19.4 5794 2.01 21 6154 2.29 23 6858 2.92 27 CFM / Static Pressure in Inches WG 1 1.25 1.5 1.75 2 2.25 2.5 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM -=(RPM/3371) (RPM/838)33 MAXIMUM MAXIMUM RPM RPM =- 1710 1230 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 2.929 x 6.414 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE=-184T 56 2643 0.75 10.5 3536 1.03 12.7 4119 1.29 14.4 4660 1.57 16.3 5075 1.81 18.2 5459 2.06 20 5852 2.36 22 6611 3.01 27 2648 0.95 12.0 3545 1.27 13.5 4185 1.56 15.4 4643 1.82 17.1 5082 2.10 18.7 5520 2.41 21 6316 3.08 25 2557 1.13 13.0 3602 1.53 14.8 4157 1.804 16.4 4649 2.10 18.3 5124 2.42 20 6009 3.14 25 3492 1.74 15.6 4136 2.07 17.7 4703 2.41 19.3 5649 3.15 23 3346 1.93 16.4 4173 2.37 18.6 5263 3.14 22 3299 2.17 17.7 4812 3.10 22 4265 3.02 22 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-240 - Belt Drive ® 423/4 (1086) H- W.G. f thi s sys 53/4 (146) t to the l ef t o 12 (305) 34 (864) 5 (127) tem curv e *311/2 (800) no ts ele c Damper Size = 24 x 24 (610 x 610) Roof Opening = 261/2 x 261/2 (673 x 673) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 158 lb. (72 kg) Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-240-4 HP (Size) Fan RPM 1/4 425 460 H-GB-240-3 1/3 505 H-GB-240-5 1/2 585 H-GB-240-7 3/4 623 660 H-GB-240-10 1 730 H-GB-240-15 11/2 778 825 H-GB-240-20 2 870 910 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 3902 0.19 5.9 4223 0.24 6.7 4637 0.32 7.8 5371 0.50 10.3 5720 0.60 11.7 6060 0.71 13.1 6702 0.96 15.8 7143 1.16 17.7 7575 1.39 19.7 7988 1.63 22 8355 1.86 24 0.125 3422 0.21 5.9 3785 0.26 6.6 4242 0.35 7.5 5031 0.53 9.7 5400 0.64 11.0 5757 0.75 12.4 6428 1.01 15.0 6886 1.21 16.6 7332 1.44 18.6 7757 1.68 21 8135 1.92 23 0.25 2691 0.20 4.7 3188 0.27 5.7 3761 0.35 6.9 4666 0.54 9.1 5069 0.65 10.4 5449 0.78 11.8 6158 1.05 14.3 6632 1.26 15.9 7092 1.49 17.7 7529 1.73 19.6 7916 1.97 21 CFM / Static Pressure in Inches WG 0.375 0.5 0.625 0.75 2036 0.22 4.2 3060 0.34 6.1 4195 0.55 8.8 4660 0.66 10.0 5094 0.79 11.3 5861 1.05 13.8 6363 1.27 15.4 6844 1.51 17.2 7300 1.77 19.1 7700 2.02 21 1 1.25 1.5 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM == (RPM/3371) (RPM/715)33 MAXIMUM MAXIMUM RPM RPM == 1710 910 TIP SPEED TIP SPEED (ft/min.) = RPM = RPM x 2.929 x 6.414 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE==184T 56 3562 0.53 8.2 4131 0.65 9.6 4636 0.78 11.0 5507 1.06 13.4 6058 1.28 15.0 6574 1.52 16.8 7055 1.78 18.7 7467 2.03 21 2112 0.41 7.2 3428 0.61 9.1 4073 0.76 10.6 5077 1.06 13.1 5700 1.29 14.7 6261 1.54 16.4 6775 1.80 18.3 7215 2.05 20 3217 0.69 10.4 4568 1.03 12.9 5266 1.28 14.4 5901 1.53 16.2 6457 1.80 17.9 6933 2.06 19.6 4145 1.18 13.2 5002 1.48 14.8 5680 1.77 16.9 6240 2.05 19.2 7757 1.68 21 5388 1.97 16.7 3707 1.66 13.6 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 35 H-GB-240HP - Belt Drive ® 423/4 (1086) H- to the le ft o 12 (305) 34 (864) 5 (127) f th is s yste m 53/4 (146) curv e W.G. *311/2 (800) ele ct Damper Size = 24 x 24 (610 x 610) Roof Opening = 261/2 x 261/2 (673 x 673) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 158 lb. (72 kg) ts no Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-240HP-5 HP (Size) Fan RPM 1/2 635 685 H-GB-240HP-7 3/4 733 780 H-GB-240HP-10 1 860 H-GB-240HP-15 11/2 920 980 H-GB-240HP-20 2 1030 1080 H-GB-240HP-30 3 1133 1240 36 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 3035 0.42 8.0 3475 0.53 9.4 3877 0.64 11.0 4247 0.76 12.7 4860 0.99 15.9 5310 1.20 18.5 5751 1.43 22 6114 1.65 24 6474 1.89 27 6853 2.16 29 7610 2.80 31 0.625 2586 0.41 7.6 3147 0.53 8.8 3603 0.65 10.3 4005 0.77 11.9 4654 1.02 15.2 5118 1.23 17.4 5574 1.47 19.9 5948 1.69 23 6315 1.92 26 6702 2.20 27 7471 2.84 30 0.75 2693 0.51 8.4 3272 0.65 9.7 3740 0.78 11.3 4434 1.04 14.3 4925 1.25 16.6 5392 1.49 19.1 5776 1.72 21 6154 1.96 24 6550 2.24 26 7333 2.89 29 CFM / Static Pressure in Inches WG 1 1.25 1.5 1.75 2 2.25 2.5 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM -=(RPM/3371) (RPM/845)33 MAXIMUM MAXIMUM RPM RPM =- 1710 1240 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 2.929 x 6.414 MAXIMUM MAXIMUMMOTOR MOTORFRAME FRAMESIZE SIZE=-184T 56 2964 0.75 10.3 3915 1.05 13.2 4496 1.29 15.0 5010 1.54 17.2 5428 1.77 19.6 5826 2.02 23 6237 2.31 24 7053 2.97 28 3105 0.99 12.2 3944 1.27 13.8 4562 1.55 15.6 5039 1.80 17.6 5468 2.06 20 5914 2.36 22 6767 3.04 27 3958 1.52 14.8 4560 1.80 16.3 5062 2.08 18.2 5560 2.40 21 6469 3.10 25 3896 1.73 15.7 4555 2.05 17.3 5133 2.39 19.3 6146 3.14 24 3763 1.93 16.7 4588 2.35 18.7 5775 3.14 23 5364 3.13 23 4776 3.04 22 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-260 - Belt Drive ® 50 (1270) H- W.G. m cu rve *36 (914) this syste 81/4 (210) f t of e le to t h ec t 5 (127) 12 (305) 40 (1016) no t sel Damper Size = 30 x 30 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.051 (1.3) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 305 lb. (138 kg) Do All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-260-4 HP (Size) Fan RPM 1/4 300 365 H-GB-260-3 1/3 405 H-GB-260-5 1/2 465 H-GB-260-7 3/4 520 H-GB-260-10 1 580 H-GB-260-15 11/2 665 2 700 H-GB-260-20 735 H-GB-260-30 3 785 835 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 3875 0.12 8.0 4714 0.22 9.2 5231 0.30 10.4 6005 0.45 11.4 6716 0.63 12.9 7491 0.88 14.4 8588 1.33 16.7 9041 1.55 17.8 9493 1.79 18.9 10138 2.18 21 10784 2.62 23 0.125 3121 0.14 7.1 4130 0.25 8.8 4716 0.33 10.3 5570 0.50 10.9 6324 0.68 12.1 7137 0.93 13.7 8278 1.39 16.2 8746 1.61 17.4 9212 1.86 18.6 9875 2.26 20 10537 2.70 23 0.25 1727 0.12 7.4 3393 0.26 8.6 4095 0.35 10.3 5063 0.52 10.4 5898 0.72 11.3 6775 0.98 13.0 7979 1.44 15.8 8460 1.67 17.0 8938 1.92 18.3 9617 2.33 20 10292 2.78 22 CFM / Static Pressure in Inches WG 0.5 0.75 1 1.25 1.5 1.75 2 MAXIMUM BHP AT A GIVEN RPM = (RPM/572)3 MAXIMUM MAXIMUM RPM RPM == 1710 835 TIP SPEED TIP SPEED (ft/min.) = RPM = RPM x 7.985 x 7.985 MAXIMUM MOTOR FRAME SIZE = 184T 3745 0.53 9.6 4869 0.75 10.3 5912 1.04 12.2 7274 1.53 15.0 7811 1.77 16.2 8335 2.03 17.6 9069 2.44 19.7 9794 2.91 22 3008 0.64 9.4 4826 1.03 11.0 6474 1.57 14.2 7068 1.82 15.5 7649 2.10 16.8 8452 2.53 18.9 9225 3.02 21 5465 1.55 13.3 6227 1.83 14.8 6878 2.13 16.2 7769 2.58 18.2 8606 3.08 20 3608 1.29 12.8 4912 1.71 13.8 5916 2.09 15.6 7006 2.59 17.9 7932 3.12 19.9 4236 1.80 14.9 5949 2.49 17.1 7157 3.10 19.7 4189 2.11 16.7 6024 2.93 18.7 4294 2.49 18.6 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 37 H-GB-300 - Belt Drive ® 50 (1270) H- of t his syst em c urve W.G. *36 (914) 81/4 (210) t to the 5 (127) left 12 (305) 40 (1016) ot se lec Damper Size = 30 x 30 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.051 (1.3) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 320 lb. (145 kg) Do n All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-300-3 HP (Size) Fan RPM 1/3 300 365 H-GB-300-5 1/2 420 H-GB-300-7 3/4 475 H-GB-300-10 1 530 H-GB-300-15 11/2 600 H-GB-300-20 2 665 3 713 H-GB-300-30 760 H-GB-300-50 5 825 890 38 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0 4859 0.18 9.3 5912 0.33 9.2 6803 0.50 9.6 7694 0.72 11.4 8585 1.00 13.4 9719 1.45 15.9 10772 1.97 18.8 11549 2.43 21 12311 2.94 23 13363 3.76 25 14416 4.73 28 0.125 3976 0.19 5.3 5222 0.35 6.2 6222 0.52 8.0 7197 0.75 10.6 8150 1.04 12.9 9334 1.49 15.4 10425 2.02 18.2 11226 2.48 20 12007 3.00 22 13084 3.82 25 14157 4.79 28 0.25 4340 0.35 5.7 5537 0.53 7.0 6616 0.77 9.6 7640 1.06 12.2 8907 1.53 14.9 10060 2.06 17.7 10901 2.53 19.6 11704 3.05 21 12804 3.88 24 13898 4.85 28 CFM / Static Pressure in Inches WG 0.5 0.75 1 1.25 1.5 1.75 2 MAXIMUM MAXIMUM BHP BHP AT AT AA GIVEN GIVEN RPM RPM =- (RPM/518) (RPM/517)33 MAXIMUM MAXIMUM RPM RPM -=1710 890 TIP SPEED TIP SPEED (ft/min.) - RPM = RPM x 7.985 x 7.985 MAXIMUM MAXIMUM MOTOR MOTOR FRAME FRAME SIZE SIZE =- 184T 184T 5095 0.74 8.1 6456 1.07 10.7 7952 1.55 13.8 9228 2.11 16.8 10129 2.59 18.9 10997 3.13 21 12175 3.97 24 13335 4.96 27 4195 0.91 9.4 6721 1.52 12.2 8269 2.11 15.7 9297 2.61 18.0 10242 3.16 19.8 11501 4.02 23 12716 5.03 26 7025 2.03 13.7 8283 2.57 16.4 9369 3.15 18.6 10770 4.05 22 12073 5.06 25 6691 2.38 13.7 8293 3.06 16.8 9909 4.01 20 11379 5.09 24 6437 2.76 14.0 8885 3.90 18.7 10536 5.02 22 7128 3.56 16.1 9568 4.89 21 7963 4.54 18.7 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. H-GB-300HP - Belt Drive ® 50 (1270) H- yste mc ur v e W.G. *36 (914) 12 (305) l ef 40 (1016) to the 5 (127) to f th is s 81/4 (210) ec t Damper Size = 30 x 30 (762 x 762) Roof Opening = 321/2 x 321/2 (826 x 826) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.051 (1.3) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight = 320 lb. (145 kg) ts el Do no All dimensions in inches (millimeters). *May be greater depending on motor. ^Weight shown is largest cataloged Open Drip Proof motor. Model Number H-GB-300HP-5 HP (Size) Fan RPM 1/2 460 495 H-GB-300HP-7 3/4 565 H-GB-300HP-10 1 620 H-GB-300HP-15 11/2 710 2 748 H-GB-300HP-20 785 H-GB-300HP-30 3 840 895 H-GB-300HP-50 5 980 1065 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.5 2912 0.41 9.7 3602 0.53 10.3 4662 0.77 11.8 5398 1.01 13.4 6542 1.48 17.2 7013 1.71 18.8 7460 1.96 20 8107 2.37 23 8746 2.84 25 9722 3.68 32 10688 4.67 44 0.75 1 CFM / Static Pressure in Inches WG 1.25 1.5 1.75 2 2.25 2.5 2.75 MAXIMUM BHP AT A GIVEN RPM = (RPM/613)3 MAXIMUM RPM = 1065 TIP SPEED (ft/min.) = RPM x 7.985 MAXIMUM MOTOR FRAME SIZE = 184T 3600 0.76 10.4 4652 1.04 12.3 5954 1.53 16.0 6462 1.78 17.5 6943 2.04 19.1 7642 2.46 22 8328 2.95 24 9356 3.81 31 10351 4.81 42 3309 0.94 10.6 5269 1.55 15.3 5889 1.81 17.0 6402 2.08 18.5 7146 2.52 21 7870 3.03 23 8951 3.90 29 10006 4.94 37 4221 1.47 13.4 5027 1.78 15.7 5737 2.10 17.9 6636 2.57 21 7394 3.07 23 8531 3.99 28 9621 5.04 37 4800 2.00 16.2 5922 2.56 19.7 6892 3.11 23 8094 4.03 27 9233 5.12 36 4992 2.43 18.0 6150 3.08 22 7657 4.08 26 8831 5.17 35 5245 2.92 19.8 7029 4.09 25 8429 5.23 33 6264 3.95 24 7903 5.24 31 5222 3.69 23 7255 5.17 30 6543 5.01 29 Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free hemispherical inlet fan sone levels. 39 Specifications Direct Drive Specifications Model H-G spun aluminum exhaust fans shall be centrifugal direct driven type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan housing shall be drawn from high strength aluminum and connected to a heavy gauge steel internal frame with integral bracing and a birdscreen. Motors shall be heavy duty ball bearing type, carefully matched to the fan load, and furnished mounted to the steel drive assembly at the specified voltage, phase, and enclosure. Motors or drive assembly shall be mounted on vibration isolators. Fresh air for motor cooling shall be drawn into the motor compartment through a large space between the fan shroud and motor cover. Motors shall be readily accessible for maintenance. A disconnect shall be NEMA rated and factory installed with wiring included from the fan motor to a junction box installed within the motor compartment. A conduit chase shall be provided through the base to the motor compartment for ease of electrical wiring. All fans shall bear the AMCA Certified Ratings Seal for sound and air performance Each fan shall bear a permanently affixed manufacturer’s engraved nameplate constructed of aluminum and containing the model number and individual serial number for future identification Fans shall meet all Greenheck wind load standards and shall contain the following third party certifications • Miami-Dade NOA# 07-0503.07 • Licensed P.E. calculations shall be available for fan per ASCE 702 Minimum Design Loads for Buildings and Other Structures for exposure class C, 60 foot building height, and a type II building. • Fan shall be tested in accordance with ASTM E330-02. Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Uniform Static Air Pressure Difference and Florida Building Code Test Protocol TAS-202 at the ASCE 7-02 calculated design load. • Licensed P.E. calculations for attachment of fan to curb shall be available for ASCE 7-02 determined design pressure. • All calculations and testing shall be done by a state licensed P.E., and a certified test lab. Motors shall be heavy-duty ball bearing type, carefully matched to the fan load, and furnished mounted to the steel drive frame at the specified voltage, phase, and enclosure. Drive frame assembly shall be constructed of heavy gauge steel with engineered forms for added strength. Motors and drives shall be mounted on vibration isolators with no metal to metal contact, out of the airstream. Fresh air for motor cooling shall be drawn into the motor compartment through a large space between the fan shroud and the motor cover. Motors and drives shall be readily accessible for maintenance. Precision ground and polished fan shafts shall be mounted in pillow block ball bearings. Bearings shall be selected for a minimum (L10) life in excess of 100,000 hours (L50 average life of 500,000 hours) at maximum cataloged operating speed. Drives shall be sized for a minimum of 150% of driven horsepower. Pulleys shall be of the cast type, keyed and securely attached to the wheel and motor shafts. Motor pulleys shall be adjustable for final system balancing. A disconnect switch shall be NEMA rated and factory installed with wiring included from the fan motor to a junction box installed within the motor compartment. A conduit chase shall be provided through the base to the motor compartment for ease of electrical wiring. All fans shall be third party tested and certified for sound and air performance. Each fan shall bear a permanently affixed manufacturer’s engraved metal nameplate containing the model number and individual serial number for future identification. Fans shall meet all Greenheck wind load standards and shall contain the following third party certifications • Miami-Dade NOA# 07-0503.07 • Licensed P.E. calculations shall be available for fan per ASCE 702 Minimum Design Loads for Buildings and Other Structures for exposure class C, 60 foot building height, and a type II building. • Fan shall be tested in accordance with ASTM E 330-02. Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference and Florida Building Code Test Protocol TAS-202 at the ASCE 7-02 calculated design pressure. • Licensed P.E. calculations for attachment of fan to curb shall be available for ASCE 7-02 determined design pressure. • All calculations and testing shall be done by a state licensed P.E., and a certified test lab. Fans shall be Greenheck model H-G manufactured by Greenheck Fan Corporation in Schofield Wisconsin. Belt Drive Specifications Model H-GB spun aluminum exhaust fans shall be centrifugal belt driven type. The fan wheel shall be centrifugal backward inclined, constructed of aluminum and shall include a wheel cone carefully matched to the inlet cone for precise running tolerances. Wheels shall be statically and dynamically balanced. The fan housing shall be drawn from high strength aluminum and connected to a heavy gauge steel internal frame with integral bracing and a birdscreen. Fans shall be Greenheck models H-GB and H-GB-HP, manufactured by Greenheck Fan Corporation in Schofield, Wisconsin. Our Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Prepared to Support Green Building Efforts Catalog H-G & H-GB Rev. 2 November 2007 Copyright © 2007 Greenheck Fan Corp.