GAMMA Building Management Systems N 262E01 binary input device 8 x potential-free contacts With broad use in versatile applications Advantages • For polling potential-free contacts • Status display per input, even without bus voltage • Numerous input functions • Easy parameter setting • With bus terminal and contact system for bus connection • Only half a standard bus load Electrical Installation from A to Z • Attractive channel price Recording and transmitting binary information is a frequently used function in commercial and residential buildings. With the N 262E01 binary input device, you have an extremely versatile device for numerous applications. Inputs can be used individually as well as in pairs, e. g., for Venetian blind switches. The N 262E01 binary input device polls the switching status of eight potential-free contacts. The voltage pulses for contact polling are generated by the device itself. w w w. s i e m e n s . c o m / g a m m a GAMMA Building Management Systems Applications Binary input device for: • Monitoring installations • Reporting switching status • Recording and transmitting states and actuations of switches and pushbuttons • Pulse counting with / without threshold check • 16-bit floating point value, edge-triggered • Switching, short / long operation • 16-bit floating point value, short / long operation • 1-button dimming • 8-bit pulse counting without threshold check • 1-button solar protection control • 8-bit pulse counting with threshold check • 1-button group control (sequence control) • 16-bit pulse counting without threshold check • 1-bit scene control • 16-bit pulse counting with threshold check • 8-bit scene control • 32-bit pulse counting without threshold check • 8-bit value, edge-triggered • 32-bit pulse counting with threshold check respectively with a function to be assigned to a pair of inputs: • 2-button dimming with stop telegram • 2-button solar protection control with selectable blocking / releasing of each input by a blocking object, with sending of the input objects after a change of status, with selectable cyclical sending of the input objects, with integrated bus coupling unit with only half a standard bus load, with connection to the bus line either via the bus terminal or via the contact system to the data rail, as device in N-system dimensions with snap-on mounting on a DIN rail EN 60715-TH35-7.5, width 6 MU (1 Module Unit = 18 mm). Ordering Data Product Order No. Packing units (items) N 262E01 binary input device, 5WG1 262-1EB01 1 8 x potential-free contacts For technical details, see the Internet. Siemens AG Automation and Drives Electrical Installation Technology P.O. Box 10 09 53 93009 REGENSBURG GERMANY w w w. s i e m e n s . c o m / g a m m a © Siemens AG 2006 Subject to change without prior notice E20001-A6000-P430-X-7600 development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. • Switching, edge-triggered The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further with 8 inputs for potential-free contacts, with a length of unshielded connecting cable per input of max. 100 m, with an integrated power supply for AC 230 V to supply the electronics, with 1 green LED for displaying the 230 V operating voltage, with 1 red LED per binary input for status display, with a function to be selected and assigned per input: • 8-bit value, short / long operation • Switching status / binary value transmission All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. N 262E01 binary input device, 8 x potential-free contact,