9. Certificate of NVLAP Accreditation

advertisement
FCC DoC TEST REPORT
Report No. : D47S026
FCC DOC TEST REPORT
Equipment
Broadband Router
Model No.
BR-6104K, BR-6104KP (EDIMAX)
GR-D4T1K, GR-G4T1KP (GLP)
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan
 The test result refers exclusively to the test presented test model / sample.
 Without written approval of SPORTON International Inc., the test report shall
not be reproduced except in full.
 Certificate or Test Report must not be used by the applicant to claim the product in
this test report endorsement by NVLAP or any agency of U.S. government.
SPORTON International Inc.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
FCC DoC TEST REPORT
Report No. : D47S026
Table of Contents
History of this test report .................................................................................................................................... ii
CERTIFICATE OF COMPLIANCE ........................................................................................................................ 1
1. General Description of Equipment under Test ............................................................................................. 2
1.1. Basic Description of Equipment under Test ................................................................................................................................ 2
1.2. Feature of Equipment under Test ............................................................................................................................................... 2
2. Test Configuration of Equipment under Test ............................................................................................... 3
2.1. Test System ............................................................................................................................................................................... 3
2.2. Connection Diagram of Test System .......................................................................................................................................... 5
3. Test Software ................................................................................................................................................... 6
4. General Information of Test............................................................................................................................ 7
4.1. Test Facility ................................................................................................................................................................................ 7
4.2. Test Voltage ............................................................................................................................................................................... 7
5. Test of Conducted Powerline ......................................................................................................................... 8
5.1. Test Procedure .......................................................................................................................................................................... 9
5.2. Test Result of AC Powerline Conducted Emission ................................................................................................................... 10
6. Test of Radiated Emission............................................................................................................................ 12
6.1. Test Procedure ........................................................................................................................................................................ 12
6.2. Test Result of Radiated Emission............................................................................................................................................. 13
7. List of Test Instrument .................................................................................................................................. 17
8. Uncertainty of Test Site ................................................................................................................................ 18
9. Certificate of NVLAP Accreditation ............................................................................................................. 19
Appendix A. Test Photographs ............................................................................................................ A1 ~ A2
Appendix B. Photographs of EUT ........................................................................................................ B1 ~ B10
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: i
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
History of this test report
Original Report Issue Date: Aug. 12, 2004
■ No additional attachment.
□ Additional attachment were issued as following record:
Attachment No.
Issue Date
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Description
Page Number
: ii
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
Certificate No. : D47S026
CERTIFICATE OF COMPLIANCE
Authorized under Declaration of Conformity
According to
47 CFR, Part 2
Equipment
Broadband Router
Model No.
BR-6104K, BR-6104KP (EDIMAX)
GR-D4T1K, GR-G4T1KP (GLP)
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan
I hereby certify that:
The measurements shown in this test report were made in accordance with the procedures given in
ANSI C63.4 - 2001.
The equipment was passed the test performed according to
47 CFR, Part 15 subpart B and CISPR PUB. 22 Class B.
The test was completed on Aug. 04, 2004.
__________________________
Alex Chen
Manager
SPORTON International Inc.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd.,
Hsi Chih, Taipei Hsien, Taiwan, R.O.C.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 1 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
1.
Report No. : D47S026
General Description of Equipment under Test
1.1. Basic Description of Equipment under Test
TP Cable x 5
: Non-Shielded, 1m
USB Cable
: Shielded, 1m
Power Supply Type : Linear (DVE / DV-1280-3)
AC Power Input
: Wall-mount, 2pin
DC Power Cable
: Non-Shielded, 1.8m
1.2. Feature of Equipment under Test
Please refer to user manual
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 2 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
2.
Report No. : D47S026
Test Configuration of Equipment under Test
2.1. Test System
Support Unit 1. -- Personal Computer (COMPAQ)
FCC ID
: N/A
Model No.
: Evo D380mx
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0102
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 2. -- Monitor (VIEWSONIC)
FCC ID
: N/A
Model No.
: E55
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0059
Data Cable
: Shielded, 1.5m
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 3. -- PS/2 Mouse (LOGITECH)
FCC ID
: DZL211029
Model No.
: M-S34
Serial No.
: SP0042
Data Cable
: Shielded, 1.75m
Support Unit 4. -- PS/2 Keyboard (BTC)
FCC ID
: E5XKB9110
Model No.
: 9110
Serial No.
: SP0129
Data Cable
: Shielded, 1.75m
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 3 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
Support Unit 5. – Printer (EPSON)
FCC ID
: N/A
Model No.
: C61
Power Supply Type
: Linear
Power Cord
: Non-Shielded
Serial No.
: SP0048
Data Cable
: Shielded, 1.2m
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 6. -- Modem (ACEEX)
FCC ID
: IFAXDM1414
Model No.
: DM1414
Power Supply Type
: Linear
Power Cord
: Non-Shielded
Serial No.
: SP0015
Data Cable
: Shielded, 1.15m
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 4 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
2.2. Connection Diagram of Test System
5
1
2
EUT
Printer
Monitor
6
PC
7
4
Modem
8
3
PS/2 Keyboard
PS/2 Mouse
1.
The TP cable is connected from PC to the EUT.
2.
The I/O cable is connected from PC to the support unit 2.
3.
The I/O cable is connected from PC to the support unit 3.
4.
The I/O cable is connected from PC to the support unit 4.
5.
The USB cable is connected from EUT to the support unit 5.
6.
The I/O cable is connected from PC to the support unit 6.
7.
These TP cables (x4) are floating.
8.
The USB cable is floating.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 5 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
3.
Report No. : D47S026
Test Software
An executive program, EMCTEST.EXE under WIN XP, which generates a complete line of continuously
repeating “ H “ pattern was used as the test software.
The program was executed as follows :
a. Turn on the power of all equipment.
b. The PC reads the test program from the hard disk drive and runs it.
c. The PC sends “ H“ messages to the monitor, and the monitor displays “ H “ patterns on the screen.
d. The PC sends “ H “ messages to the modem.
e. The PC sends “ H ” messages to the internal Hard Disk, and the Hard Disk reads and writes the
message.
f. Repeat the steps from c to f.
At the same time, the printer printing data sent from PC via TP cable, USB cable and EUT.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 6 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
4.
Report No. : D47S026
General Information of Test
4.1. Test Facility
Test Site Location
:
No. 3, Lane 238, Kang Lo Street, Nei Hwu District,
Taipei 11424, Taiwan, R.O.C.
TEL: 886-2-2631-4739
FAX: 886-2-2631-9740
Test Site No
:
CO01-NH, OS02-NH
4.2. Test Voltage
110V/60Hz
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 7 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
5.
Report No. : D47S026
Test of Conducted Powerline
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz and return
leads of the EUT according to the methods defined in ANSI C63.4-2001 Section 3.1.
The EUT was
placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown below.
The interface cables and equipment positioning were varied within limits of reasonable applications to
determine the position produced maximum conducted emissions
10 cm
80 cm to the ground plane
L.I.S.N.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
L.I.S.N.
Page Number
: 8 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
5.1. Test Procedure
a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from
the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded
conducting surface.
b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
c.
All the support units are connect to the other LISN.
d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
e. The CISPR states that a 50 ohm, 50 microhenry LISN should be used.
f.
Both sides of AC line were checked for maximum conducted interference.
g. The frequency range from 150 kHz to 30 MHz was searched.
h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
Mode.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 9 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
5.2. Test Result of AC Powerline Conducted Emission






Frequency Range of Test: from 0.15 MHz to 30 MHz
Temperature: 26 C
Relative Humidity: 53 %
Test Date: Aug. 04, 2004
Corrected Reading (dBuV) = Insertion Loss + Cable Loss + Read Level = Level
All emissions not reported here are more than 10 dB below the prescribed limit.
■ The test was passed at the minimum margin that marked under gray area in the following table
LINE
Limit Line Read Level Insertion
Loss (dB)
(dBV)
(dBV)
Frequency
(MHz)
Level
(dBV)
Over
Limit (dB)
0.191
49.23
-14.76
63.99
49.10
0.10
0.03
QP
0.191
21.63
-32.36
53.99
21.50
0.10
0.03
AV
0.230
47.44
-15.01
62.45
47.30
0.10
0.04
QP
0.230
19.44
-33.01
52.45
19.30
0.10
0.04
AV
0.285
45.45
-15.22
60.67
45.30
0.10
0.05
QP
0.285
18.25
-32.42
50.67
18.10
0.10
0.05
AV
0.499
40.87
-15.15
56.02
40.70
0.10
0.07
QP
0.499
13.97
-32.05
46.02
13.80
0.10
0.07
AV
0.591
39.08
-16.92
56.00
38.90
0.10
0.08
QP
0.591
12.68
-33.32
46.00
12.50
0.10
0.08
AV
10.162
36.70
-23.30
60.00
36.20
0.30
0.20
QP
10.162
33.00
-17.00
50.00
32.50
0.30
0.20
AV
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Cable Loss Detect Mode
(dB)
(QP or AV)
Page Number
: 10 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
NEUTRAL
Frequency
(MHz)
Level
(dBV)
Over
Limit (dB)
Limit Line Read Level Insertion
Loss (dB)
(dBV)
(dBV)
0.195
48.73
-15.09
63.82
48.60
0.10
0.03
QP
0.195
20.43
-33.39
53.82
20.30
0.10
0.03
AV
0.423
47.66
-9.73
57.39
47.50
0.10
0.06
QP
0.423
19.06
-28.33
47.39
18.90
0.10
0.06
AV
0.498
44.67
-11.36
56.03
44.50
0.10
0.07
QP
0.498
11.37
-34.66
46.03
11.20
0.10
0.07
AV
0.568
36.78
-19.22
56.00
36.60
0.10
0.08
QP
0.568
12.28
-33.72
46.00
12.10
0.10
0.08
AV
9.235
29.38
-30.62
60.00
28.90
0.28
0.20
QP
9.235
21.78
-28.22
50.00
21.30
0.28
0.20
AV
10.162
36.10
-23.90
60.00
35.60
0.30
0.20
QP
10.162
31.80
-18.20
50.00
31.30
0.30
0.20
AV
Cable Loss Detect Mode
(dB)
(QP or AV)
Test Engineer:
Cash Chu
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 11 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
6.
Report No. : D47S026
Test of Radiated Emission
Radiated emissions from 30 MHz to 1,000 MHz were measured with a bandwidth of 120 kHz according
to the methods defines in ANSI C63.4-2001.
The EUT was placed on a nonmetallic stand, 0.8 meter
above the ground plane, as shown below. The interface cables and equipment positions were varied
within limits of reasonable applications to determine the positions producing maximum radiated
emissions.
Antenna
Equipment under Test
Test Distance
0.8 M
Ground
Plane
 10 M for other tests
Receiver
TurnTable
6.1. Test Procedure
a. The EUT was placed on a rotatable table top 0.8 meter above ground.
b. The EUT was set 10 meters from the interference-receiving antenna which was mounted on the top of
a variable height antenna tower.
c.
The table was rotated 360 degrees to determine the position of the highest radiation.
d. The antenna is a half wave dipole and its height is varied between one meter and four meters above
ground to find the maximum value of the field strength both horizontal polarization and vertical
polarization of the antenna are set to make the measurement.
e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower
(from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading.
f.
Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold
Mode.
g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will
be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB
margin will be repeated one by one using the quasi-peak method and reported.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 12 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
6.2. Test Result of Radiated Emission
 Temperature: 26 C
 Relative Humidity: 53 %
 Corrected Reading: Antenna Factor + Cable Loss + Read Level  Preamp Factor = Level
■ The test was passed at the minimum margin that marked by a frame in the following table
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 13 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Report No. : D47S026
Page Number
: 14 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Report No. : D47S026
Page Number
: 15 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
Report No. : D47S026
Test Engineer:
Chay Yeh
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 16 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
7.
Report No. : D47S026
List of Test Instrument
Instrument
Manufacturer
Model No.
Serial No.
Characteristics
Calibration Date
Remark
Spectrum Monitor
R&S
EZM
894987/011
9KHz – 1.3GHz
Aug. 06, 2003
Conduction
(CO01-NH)
Test Receiver
R&S
ESH3
893495/013
9 KHz - 30 MHz
Sep. 16, 2003
Conduction
(CO01-NH)
LISN
Rolf Heine
NNB-2/16Z
99079
9 KHz - 30 MHz
Dec. 25, 2003
Conduction
(CO01-NH)
LISN
KYORITSU
KNW-407
8-1010-15
9 KHz - 30 MHz
Nov. 28, 2003
Conduction
(CO01-NH)
Power Filter
CORCOM
MR12030
N/A
30A*2
N/A
Conduction
(CO01-NH)
Open Area Test Site
SPORTON
OATS-10
OS02-NH
30MHz~1GHz
10m, 3m
Jan. 10, 2004
Spectrum Analyzer
Advantest
RS3261C
71720471
9KHz – 2.6GHz
Feb. 26, 2004
AMPLIFIER
HP
8447D
2944A07523
0.1MHz ~ 1.3GHz
Apr. 07, 2004
Bilog Antenna
CHASE
CBL6122B
2631
30MHz - 2GHz
Jun. 19, 2004
Turn Table
EMCO
2080
9508-1805
0  360 degree
N/A
Antenna Mast
ETS
2075-2
2385
1m-4m
N/A
RF Cable-R10m
MIYAZAKI
5DFB
CB002
30MHz~1GHz
Sep. 08, 2003
Receiver
R&S
ESCS 30
838251/002
9 K – 2.75 GHz
Jan. 05, 2004
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
Radiation
(OS02-NH)
※ Calibration Interval of instruments listed above is one year.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 17 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
8.
Report No. : D47S026
Uncertainty of Test Site
Uncertainty of Conducted Emission Measurement
Contribution
Probability
Distribution
Cable and I/P attenuator calibration
normal(k=2)
RCV/SPA specification
Rectangular
LISN coupling specification
rectangular
Transducer factor frequency interpolation
rectangular
Mismatch
U-shaped
Receiver VSWR 1=0.09
LISN VSWR 2=0.33
Uncertainty=20log(1-1*2)
combined standard uncertainty Ue(y)
normal
Measuring uncertainty for a level of confidence normal (k=2)
of 95%
U=2Ue(y)
U=√{(0.3/2)² +(2²+1.5²+0.2²)/3+(0.2)²/2}=1.66
Uncertainty of Radiated Emission Measurement
Contribution
Probability
Distribution
normal(k=2)
normal(k=2)
rectangular
rectangular
rectangular
rectangular
rectangular
150KHz – 30MHz
±0.3
±2
±1.5
±0.2
0.2
±1.66
±3.32
3m
10m
Antenna factor calibration
±1.6
±1.6
cable loss calibration
±0.3
±0.3
RCV/SPA specification
±2
±2
Antenna Directivity
±3
±0.5
Antenna Factor V.S. Height
±2
±2
Antenna Factor Interpolation for Frequency
±0.25
±0.25
site imperfection
±2
±2
Mismatch
Receiver VSWR 1=0.09
U-shaped
±0.54
±0.54
Antenna VSWR 2=0.67
Uncertainty=20log(1-1*2)
combined standard uncertainty Ue(y)
normal
±2.8
±2.2
Measuring uncertainty for a level of confidence normal (k=2)
±5.6
±4.4
of 95%
U=2Ue(y)
U=√{(1.6/2)²+(0.3/2)²+(3²+0.5²+2²+0.25²+2²)/3+(0.54)²/2}=2.2 for 10m test distance
U=√{(1.6/2)²+(0.3/2)²+(3²+3²+2²+0.25²+2²)/3+(0.54)²/2}=2.8 for 3m test distance
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 18 of 19
Issued Date
: Aug. 12, 2004
FCC DoC TEST REPORT
9.
Report No. : D47S026
Certificate of NVLAP Accreditation
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 19 of 19
Issued Date
: Aug. 12, 2004
Download