FCC DoC TEST REPORT Report No. : FD5NS006 FCC DOC TEST REPORT Equipment 8-Port Gigabit Desktop Switch Model No. ES-5800P, GS-G08P Trade Name EDIMAX, GLP Applicant EDIMAX TECHNOLOGY CO., LTD. No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan, R.O.C. The test result refers exclusively to the test presented test model / sample. Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full. Certificate or Test Report must not be used by the applicant to claim the product in this test report endorsement by NVLAP or any agency of U.S. government. SPORTON International Inc. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 FCC DoC TEST REPORT Report No. : FD5NS006 Table of Contents History of this test report .................................................................................................................................... ii CERTIFICATE OF COMPLIANCE ........................................................................................................................ 1 1. General Description of Equipment under Test ............................................................................................. 2 1.1. Basic Description of Equipment under Test ................................................................................................................................ 2 1.2. Feature of Equipment under Test ............................................................................................................................................... 2 2. Test Configuration of Equipment under Test ............................................................................................... 3 2.1. Test System ............................................................................................................................................................................... 3 2.2. Connection Diagram of Test System .......................................................................................................................................... 5 3. Test Software ................................................................................................................................................... 6 4. General Information of Test............................................................................................................................ 7 4.1. Test Facility ................................................................................................................................................................................ 7 4.2. Test Voltage ............................................................................................................................................................................... 7 5. Test of Conducted Powerline ......................................................................................................................... 8 5.1. Test Procedure .......................................................................................................................................................................... 9 5.2. Test Result of AC Powerline Conducted Emission ................................................................................................................... 10 6. Test of Radiated Emission............................................................................................................................ 12 6.1. Test Procedure ........................................................................................................................................................................ 13 6.2. Test Result of Radiated Emission............................................................................................................................................. 14 7. List of Test Instrument .................................................................................................................................. 18 8. Uncertainty of Test Site ................................................................................................................................ 19 9. Certificate of NVLAP Accreditation ............................................................................................................. 20 Appendix A. Test Photographs ............................................................................................................ A1 ~ A2 Appendix B. Photographs of EUT ........................................................................................................ B1 ~ B10 SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : i Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 History of this test report Original Report Issue Date: Dec. 05, 2005 ■ No additional attachment. □ Additional attachment were issued as following record: Attachment No. Issue Date SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Description Page Number : ii Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 Certificate No. : FD5NS006 CERTIFICATE OF COMPLIANCE Authorized under Declaration of Conformity According to 47 CFR, Part 2 Equipment 8-Port Gigabit Desktop Switch Model No. ES-5800P, GS-G08P Trade Name EDIMAX, GLP Applicant EDIMAX TECHNOLOGY CO., LTD. No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park, Taipei Hsien, Taiwan, R.O.C. I hereby certify that: The measurements shown in this test report were made in accordance with the procedures given in ANSI C63.4 - 2003. The equipment was passed the test performed according to 47 CFR, Part 15 subpart B and CISPR PUB. 22 Class B. The test was completed on Nov. 30, 2005. _____________________________ Alex Chen Manager SPORTON International Inc. 6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih, Taipei Hsien, Taiwan, R.O.C. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 1 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 1. General Description of Equipment under Test 1.1. Basic Description of Equipment under Test STP Cable : Shielded, 10.0m STP Cable : Shielded, 1.0m Power Supply Type : Linear AC Power Input : Wall-mount, 2pin DC Power Cable : Non-Shielded, 1.8m, 3pin 1.2. Feature of Equipment under Test Please refer to user manual. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 2 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 2. Test Configuration of Equipment under Test 2.1. Test System Support Unit 1. -- Personal Computer (hp compaq) – for local workstation FCC ID : N/A Model No. : d330uT Power Supply Type : Switching Power Cord : Non-Shielded Serial No. : SP0014 Remark : This support device was tested to comply with FCC standards and authorized under a declaration of conformity. Support Unit 2. -- Monitor (COMPAQ) – for local & remote workstation FCC ID : N/A Model No. : S510 Power Supply Type : Switching Power Cord : Non-Shielded Serial No. : SP0025 Data Cable : Shielded, 1.7m Remark : This support device was tested to comply with FCC standards and authorized under a declaration of conformity. Support Unit 3. -- PS/2 Keyboard (COMPAQ) – for local & remote workstation FCC ID : N/A Model No. : 6511-VA Serial No. : SP0038 Data Cable : Shielded, 1.7m Remark : This support device was tested to comply with FCC standards and authorized under a declaration of conformity. Support Unit 4. -- PS/2 Mouse (COMPAQ) – for local & remote workstation FCC ID : JNZ211443 Model No. : M-S69 Serial No. : SP0047 Data Cable : Non-Shielded, 1.8m SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 3 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 Support Unit 5. -- Printer (HP) – for local workstation FCC ID : B94C2642X Model No. : DJ 400 Power Supply Type : Linear Power Cord : Non-Shielded Serial No. : SP0057 Data Cable : Shielded, 360 degree via metal backshells, 1.35m Support Unit 6. -- Modem (ACEEX) – for local workstation FCC ID : IFAXDM1414 Model No. : DM1414 Power Supply Type : Linear Power Cord : Non-Shielded Serial No. : SP0063 Data Cable : Shielded, 360 degree via metal backshells, 1.15m Support Unit 7. -- Personal Computer (COMPAQ) – for remote workstation FCC ID : N/A Model No. : Evo D380mx Power Supply Type : Switching Power Cord : Non-Shielded Serial No. : SP0018 Remark : This support device was tested to comply with FCC standards and authorized under a declaration of conformity. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 4 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 2.2. Connection Diagram of Test System 8 6 2 to remote workstation 5 1 EUT Printer Monitor Modem PC 7 3 4 PS/2 Keyboard PS/2 Mouse 1. The STP cable is connected from PC to the EUT. 2. The I/O cable is connected from PC to the support unit 2. 3. The I/O cable is connected from PC to the support unit 3. 4. The I/O cable is connected from PC to the support unit 4. 5. The I/O cable is connected from PC to the support unit 5. 6. The I/O cable is connected from PC to the support unit 6. 7. These STP cables are floating. 8. The STP cable is connected from EUT to the remote workstation. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 5 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 3. Test Software An executive program, EMITEST.EXE under WIN XP, which generates a complete line of continuously repeating “ H “ pattern was used as the test software. The program was executed as follows : a. Turn on the power of all equipment. b. The PC reads the test program from the hard disk drive and runs it. c. The PC sends " H " messages to the monitor, and the monitor displays " H" patterns on the screen. d. The PC sends “ H “ messages to the printer, then the printer prints them on the paper. e. The PC sends “ H “ messages to the modem. f. The PC sends " H " messages to the internal hard disk, and the Hard Disk reads and writes the message. g. Repeat the steps from c to f. At the same time, “ Ping ” was executed to link with the remote workstation to receive and transmit data by STP cable. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 6 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 4. General Information of Test 4.1. Test Facility Test Site Location : Test Site No. : No. 30-2, Lin 6, Diing-Fwu Tsuen, Lin-Kou-Hsiang, Taipei Hsien, Taiwan, R.O.C. TEL : 886-2-2601-1640 FAX : 886-2-2601-1695 CO01-LK, OS04-LK 4.2. Test Voltage 120V / 60Hz SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 7 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 5. Test of Conducted Powerline Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz and return leads of the EUT according to the methods defined in ANSI C63.4-2003 Section 3.1. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown below. The interface cables and equipment positioning were varied within limits of reasonable applications to determine the position produced maximum conducted emissions 10 cm 80 cm to the ground plane L.I.S.N. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 L.I.S.N. Page Number : 8 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 5.1. Test Procedure a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded conducting surface. b. Connect EUT to the power mains through a line impedance stabilization network (LISN). c. All the support units are connect to the other LISN. d. The LISN provides 50 ohm coupling impedance for the measuring instrument. e. The CISPR states that a 50 ohm, 50 microhenry LISN should be used. f. Both sides of AC line were checked for maximum conducted interference. g. The frequency range from 150 kHz to 30 MHz was searched. h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 9 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 5.2. Test Result of AC Powerline Conducted Emission Frequency Range of Test : from 150 kHz to 30 MHz Temperature : 24 C Relative Humidity : 51 % Corrected Reading (dBuV) = LISN Factor + Cable Loss + Read Level = Level ■ The test was passed at the minimum margin that marked by a frame in the following data SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 10 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 Test Engineer : Josh Lin SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 11 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 6. Test of Radiated Emission Radiated emissions from 30 MHz to 1,000 MHz were measured with a bandwidth of 120 kHz according to the methods defines in ANSI C63.4-2003. The EUT was placed on a nonmetallic stand, 0.8 meter above the ground plane, as shown below. The interface cables and equipment positions were varied within limits of reasonable applications to determine the positions producing maximum radiated emissions. Antenna Equipment under Test Test Distance 0.8 M Ground Plane 10 M for other tests Receiver TurnTable SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 12 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 6.1. Test Procedure a. The EUT was placed on a rotatable table top 0.8 meter above ground. b. The EUT was set 10 meters from the interference-receiving antenna which was mounted on the top of a variable height antenna tower. c. The table was rotated 360 degrees to determine the position of the highest radiation. d. The antenna is a half wave dipole and its height is varied between one meter and four meters above ground to find the maximum value of the field strength both horizontal polarization and vertical polarization of the antenna are set to make the measurement. e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading. f. Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold Mode. g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB margin will be repeated one by one using the quasi-peak method and reported. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 13 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 6.2. Test Result of Radiated Emission Temperature : 24 C Relative Humidity : 62 % Corrected Reading : Antenna Factor + Cable Loss + Read Level Preamp Factor = Level ■ The test was passed at the minimum margin that marked by the frame in the following test record SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 14 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Report No. : FD5NS006 Page Number : 15 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Report No. : FD5NS006 Page Number : 16 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 Test Engineer : Benny Lee SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 17 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 7. List of Test Instrument Instrument Manufacturer Model No. Serial No. Characteristics Calibration Date Remark Receiver R&S ESCS 30 8368581024 9 kHz - 2.75 GHz Jul. 20, 2005 Conduction (CO01-LK) LISN Rolf Hoine NNB-2/16Z 98087 9 kHz - 30 MHz Sep. 12, 2005 Conduction (CO01-LK) LISN Rolf Hoine NNB-2/16Z 98009 9 kHz - 30 MHz Sep. 21, 2005 Conduction (CO01-LK) RF Cable-CON Suhner Switzerland RG223/U CB017 9 kHz - 30 MHz Dec. 17, 2004 Conduction (CO01-LK) Open AreaTest Site SPORTON OATS-10 OS04-LK 30 MHz - 1 GHz 10m, 3m Aug. 06, 2005 Radiation (OS04-LK) Amplifier HP 87405A 3207A01437 10 MHz - 3 GHz Sep. 14, 2005 Radiation (OS04-LK) SpectrumAnalyzer HP 8560E 3728A03186 9 kHz - 1.8 GHz Dec. 29, 2004 Radiation (OS04-LK) Receiver R&S ESCS 30 100359 9 kHz - 2.75 GHz Aug. 11, 2005 Radiation (OS04-LK) Bilog Antenna CHASE CBL6112B 2288 30 MHz - 2 GHz Jun. 08, 2005 Radiation (OS04-LK) Turn Table EMCO 2080 9711-2021 0 - 360 degree N/A Radiation (OS04-LK) Antenna Mast EMCO 2075 9711-2115 1m-4m N/A Radiation (OS04-LK) RF Cable-R10m BELDEN RG8/U CB011 30 MHz - 1 GHz Jan. 08, 2005 Radiation (OS04-LK) RF Cable-R03m BELDEN RG8/U CB012 30 MHz - 1 GHz Jan. 08, 2005 Radiation (OS04-LK) ※ Calibration Interval of instruments listed above is one year. SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 18 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT Report No. : FD5NS006 8. Uncertainty of Test Site Uncertainty of Conducted Emission Measurement (150kHz ~ 30MHz) x Contribution Receiver reading Cable loss AMN insertion loss Receiver Spec Uncertainty of i Probability dB Distribution 0.15 Normal(k=2) 0.21 Normal(k=2) 2.50 Rectangular 1.50 Rectangular Site imperfection 1.56 Mismatch +0.34/-0.35 combined standard uncertainty Uc(y) Measuring uncertainty for a level of confidence of 95% U=2Uc(y) Uncertainty of Radiated Emission Measurement Rectangular U-shape 1.21 Receiver reading Antenna factor calibration Cable loss calibration Pre Amplifier Gain calibration RCV/SPA specification Antenna Factor Interpolation for Frequency Site imperfection Mismatch combined standard uncertainty Uc(y) Measuring uncertainty for a level of confidence of 95% U=2Uc(y) SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 0.08 0.11 0.63 0.43 0.90 0.24 2.42 (30MHz ~ 1000MHz) x Contribution u xi Uncertainty of i Probability dB Distribution 0.19 Normal(k=2) 1.07 Normal(k=2) 0.23 Normal(k=2) 0.22 Normal(k=2) 2.50 Rectangular 1.00 Rectangular 1.81 Rectangular +0.42/-0.44 U-shaped 1.45 u xi 0.10 0.54 0.12 0.11 0.72 0.29 1.05 0.30 2.90 Page Number : 19 of 20 Issued Date : Dec. 05, 2005 FCC DoC TEST REPORT 9. Report No. : FD5NS006 Certificate of NVLAP Accreditation SPORTON International Inc. TEL : 886-2-2696-2468 FAX : 886-2-2696-2255 Page Number : 20 of 20 Issued Date : Dec. 05, 2005