9. Certificate of NVLAP Accreditation

advertisement
FCC DoC TEST REPORT
Report No. : FD5NS006
FCC DOC TEST REPORT
Equipment
8-Port Gigabit Desktop Switch
Model No.
ES-5800P, GS-G08P
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan, R.O.C.
 The test result refers exclusively to the test presented test model / sample.
 Without written approval of SPORTON International Inc., the test report shall
not be reproduced except in full.
 Certificate or Test Report must not be used by the applicant to claim the product in
this test report endorsement by NVLAP or any agency of U.S. government.
SPORTON International Inc.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd., Hsi Chih,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
FCC DoC TEST REPORT
Report No. : FD5NS006
Table of Contents
History of this test report .................................................................................................................................... ii
CERTIFICATE OF COMPLIANCE ........................................................................................................................ 1
1. General Description of Equipment under Test ............................................................................................. 2
1.1. Basic Description of Equipment under Test ................................................................................................................................ 2
1.2. Feature of Equipment under Test ............................................................................................................................................... 2
2. Test Configuration of Equipment under Test ............................................................................................... 3
2.1. Test System ............................................................................................................................................................................... 3
2.2. Connection Diagram of Test System .......................................................................................................................................... 5
3. Test Software ................................................................................................................................................... 6
4. General Information of Test............................................................................................................................ 7
4.1. Test Facility ................................................................................................................................................................................ 7
4.2. Test Voltage ............................................................................................................................................................................... 7
5. Test of Conducted Powerline ......................................................................................................................... 8
5.1. Test Procedure .......................................................................................................................................................................... 9
5.2. Test Result of AC Powerline Conducted Emission ................................................................................................................... 10
6. Test of Radiated Emission............................................................................................................................ 12
6.1. Test Procedure ........................................................................................................................................................................ 13
6.2. Test Result of Radiated Emission............................................................................................................................................. 14
7. List of Test Instrument .................................................................................................................................. 18
8. Uncertainty of Test Site ................................................................................................................................ 19
9. Certificate of NVLAP Accreditation ............................................................................................................. 20
Appendix A. Test Photographs ............................................................................................................ A1 ~ A2
Appendix B. Photographs of EUT ........................................................................................................ B1 ~ B10
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: i
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
History of this test report
Original Report Issue Date: Dec. 05, 2005
■ No additional attachment.
□ Additional attachment were issued as following record:
Attachment No.
Issue Date
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Description
Page Number
: ii
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
Certificate No. : FD5NS006
CERTIFICATE OF COMPLIANCE
Authorized under Declaration of Conformity
According to
47 CFR, Part 2
Equipment
8-Port Gigabit Desktop Switch
Model No.
ES-5800P, GS-G08P
Trade Name
EDIMAX, GLP
Applicant
EDIMAX TECHNOLOGY CO., LTD.
No. 3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
Taipei Hsien, Taiwan, R.O.C.
I hereby certify that:
The measurements shown in this test report were made in accordance with the procedures given in
ANSI C63.4 - 2003.
The equipment was passed the test performed according to
47 CFR, Part 15 subpart B and CISPR PUB. 22 Class B.
The test was completed on Nov. 30, 2005.
_____________________________
Alex Chen
Manager
SPORTON International Inc.
6F, No. 106, Sec. 1, Hsin Tai Wu Rd.,
Hsi Chih, Taipei Hsien, Taiwan, R.O.C.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 1 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
1. General Description of Equipment under Test
1.1. Basic Description of Equipment under Test
STP Cable
: Shielded, 10.0m
STP Cable
: Shielded, 1.0m
Power Supply Type
: Linear
AC Power Input
: Wall-mount, 2pin
DC Power Cable
: Non-Shielded, 1.8m, 3pin
1.2. Feature of Equipment under Test

Please refer to user manual.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 2 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
2. Test Configuration of Equipment under Test
2.1. Test System
Support Unit 1. -- Personal Computer (hp compaq) – for local workstation
FCC ID
: N/A
Model No.
: d330uT
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0014
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 2. -- Monitor (COMPAQ) – for local & remote workstation
FCC ID
: N/A
Model No.
: S510
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0025
Data Cable
: Shielded, 1.7m
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 3. -- PS/2 Keyboard (COMPAQ) – for local & remote workstation
FCC ID
: N/A
Model No.
: 6511-VA
Serial No.
: SP0038
Data Cable
: Shielded, 1.7m
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
Support Unit 4. -- PS/2 Mouse (COMPAQ) – for local & remote workstation
FCC ID
: JNZ211443
Model No.
: M-S69
Serial No.
: SP0047
Data Cable
: Non-Shielded, 1.8m
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 3 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
Support Unit 5. -- Printer (HP) – for local workstation
FCC ID
: B94C2642X
Model No.
: DJ 400
Power Supply Type
: Linear
Power Cord
: Non-Shielded
Serial No.
: SP0057
Data Cable
: Shielded, 360 degree via metal backshells, 1.35m
Support Unit 6. -- Modem (ACEEX) – for local workstation
FCC ID
: IFAXDM1414
Model No.
: DM1414
Power Supply Type
: Linear
Power Cord
: Non-Shielded
Serial No.
: SP0063
Data Cable
: Shielded, 360 degree via metal backshells, 1.15m
Support Unit 7. -- Personal Computer (COMPAQ) – for remote workstation
FCC ID
: N/A
Model No.
: Evo D380mx
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0018
Remark
: This support device was tested to comply with FCC standards
and authorized under a declaration of conformity.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 4 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
2.2. Connection Diagram of Test System
8
6
2
to remote
workstation
5
1
EUT
Printer
Monitor
Modem
PC
7
3
4
PS/2 Keyboard
PS/2 Mouse
1.
The STP cable is connected from PC to the EUT.
2.
The I/O cable is connected from PC to the support unit 2.
3.
The I/O cable is connected from PC to the support unit 3.
4.
The I/O cable is connected from PC to the support unit 4.
5.
The I/O cable is connected from PC to the support unit 5.
6.
The I/O cable is connected from PC to the support unit 6.
7.
These STP cables are floating.
8.
The STP cable is connected from EUT to the remote workstation.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 5 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
3. Test Software
An executive program, EMITEST.EXE under WIN XP, which generates a complete line of continuously
repeating “ H “ pattern was used as the test software.
The program was executed as follows :
a. Turn on the power of all equipment.
b. The PC reads the test program from the hard disk drive and runs it.
c. The PC sends " H " messages to the monitor, and the monitor displays " H" patterns on the screen.
d. The PC sends “ H “ messages to the printer, then the printer prints them on the paper.
e. The PC sends “ H “ messages to the modem.
f. The PC sends " H " messages to the internal hard disk, and the Hard Disk reads and writes the
message.
g. Repeat the steps from c to f.
At the same time, “ Ping ” was executed to link with the remote workstation to receive and transmit data
by STP cable.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 6 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
4. General Information of Test
4.1. Test Facility
Test Site Location
:
Test Site No.
:
No. 30-2, Lin 6, Diing-Fwu Tsuen, Lin-Kou-Hsiang,
Taipei Hsien, Taiwan, R.O.C.
TEL : 886-2-2601-1640
FAX : 886-2-2601-1695
CO01-LK, OS04-LK
4.2. Test Voltage
120V / 60Hz
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 7 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
5. Test of Conducted Powerline
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz and return
leads of the EUT according to the methods defined in ANSI C63.4-2003 Section 3.1.
The EUT was
placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as shown below.
The interface cables and equipment positioning were varied within limits of reasonable applications to
determine the position produced maximum conducted emissions
10 cm
80 cm to the ground plane
L.I.S.N.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
L.I.S.N.
Page Number
: 8 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
5.1. Test Procedure
a. The EUT was placed on a desk 0.8 meters height from the metal ground plane and 0.4 meter from
the conducting wall of the shielding room and it was kept at least 0.8 meters from any other grounded
conducting surface.
b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
c.
All the support units are connect to the other LISN.
d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
e. The CISPR states that a 50 ohm, 50 microhenry LISN should be used.
f.
Both sides of AC line were checked for maximum conducted interference.
g. The frequency range from 150 kHz to 30 MHz was searched.
h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum Hold
Mode.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 9 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
5.2. Test Result of AC Powerline Conducted Emission




Frequency Range of Test : from 150 kHz to 30 MHz
Temperature : 24 C
Relative Humidity : 51 %
Corrected Reading (dBuV) = LISN Factor + Cable Loss + Read Level = Level
■ The test was passed at the minimum margin that marked by a frame in the following data
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 10 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
Test Engineer :
Josh Lin
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 11 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
6. Test of Radiated Emission
Radiated emissions from 30 MHz to 1,000 MHz were measured with a bandwidth of 120 kHz according
to the methods defines in ANSI C63.4-2003.
The EUT was placed on a nonmetallic stand, 0.8 meter
above the ground plane, as shown below. The interface cables and equipment positions were varied
within limits of reasonable applications to determine the positions producing maximum radiated
emissions.
Antenna
Equipment under Test
Test Distance
0.8 M
Ground
Plane
 10 M for other tests
Receiver
TurnTable
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 12 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
6.1. Test Procedure
a. The EUT was placed on a rotatable table top 0.8 meter above ground.
b. The EUT was set 10 meters from the interference-receiving antenna which was mounted on the top of
a variable height antenna tower.
c.
The table was rotated 360 degrees to determine the position of the highest radiation.
d. The antenna is a half wave dipole and its height is varied between one meter and four meters above
ground to find the maximum value of the field strength both horizontal polarization and vertical
polarization of the antenna are set to make the measurement.
e. For each suspected emission the EUT was arranged to its worst case and then tune the antenna tower
(from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the maximum reading.
f.
Set the test-receiver system to Peak Detect Function and specified bandwidth with Maximum Hold
Mode.
g. If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then testing will
be stopped and peak values of EUT will be reported, otherwise, the emissions which do not have 3 dB
margin will be repeated one by one using the quasi-peak method and reported.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 13 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
6.2. Test Result of Radiated Emission
 Temperature : 24 C
 Relative Humidity : 62 %
 Corrected Reading : Antenna Factor + Cable Loss + Read Level  Preamp Factor = Level
■ The test was passed at the minimum margin that marked by the frame in the following test record
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 14 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Report No. : FD5NS006
Page Number
: 15 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Report No. : FD5NS006
Page Number
: 16 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
Test Engineer :
Benny Lee
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 17 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
7. List of Test Instrument
Instrument
Manufacturer
Model No.
Serial No.
Characteristics
Calibration Date
Remark
Receiver
R&S
ESCS 30
8368581024
9 kHz - 2.75 GHz
Jul. 20, 2005
Conduction
(CO01-LK)
LISN
Rolf Hoine
NNB-2/16Z
98087
9 kHz - 30 MHz
Sep. 12, 2005
Conduction
(CO01-LK)
LISN
Rolf Hoine
NNB-2/16Z
98009
9 kHz - 30 MHz
Sep. 21, 2005
Conduction
(CO01-LK)
RF Cable-CON
Suhner
Switzerland
RG223/U
CB017
9 kHz - 30 MHz
Dec. 17, 2004
Conduction
(CO01-LK)
Open AreaTest Site
SPORTON
OATS-10
OS04-LK
30 MHz - 1 GHz
10m, 3m
Aug. 06, 2005
Radiation
(OS04-LK)
Amplifier
HP
87405A
3207A01437
10 MHz - 3 GHz
Sep. 14, 2005
Radiation
(OS04-LK)
SpectrumAnalyzer
HP
8560E
3728A03186
9 kHz - 1.8 GHz
Dec. 29, 2004
Radiation
(OS04-LK)
Receiver
R&S
ESCS 30
100359
9 kHz - 2.75 GHz
Aug. 11, 2005
Radiation
(OS04-LK)
Bilog Antenna
CHASE
CBL6112B
2288
30 MHz - 2 GHz
Jun. 08, 2005
Radiation
(OS04-LK)
Turn Table
EMCO
2080
9711-2021
0 - 360 degree
N/A
Radiation
(OS04-LK)
Antenna Mast
EMCO
2075
9711-2115
1m-4m
N/A
Radiation
(OS04-LK)
RF Cable-R10m
BELDEN
RG8/U
CB011
30 MHz - 1 GHz
Jan. 08, 2005
Radiation
(OS04-LK)
RF Cable-R03m
BELDEN
RG8/U
CB012
30 MHz - 1 GHz
Jan. 08, 2005
Radiation
(OS04-LK)
※
Calibration Interval of instruments listed above is one year.
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 18 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
Report No. : FD5NS006
8. Uncertainty of Test Site
Uncertainty of Conducted Emission Measurement
(150kHz ~ 30MHz)
x
Contribution
Receiver reading
Cable loss
AMN insertion loss
Receiver Spec
Uncertainty of i
Probability
dB
Distribution
0.15
Normal(k=2)
0.21
Normal(k=2)
2.50
Rectangular
1.50
Rectangular
Site imperfection
1.56
Mismatch
+0.34/-0.35
combined standard uncertainty Uc(y)
Measuring uncertainty for a level of confidence
of 95%
U=2Uc(y)
Uncertainty of Radiated Emission Measurement
Rectangular
U-shape
1.21
Receiver reading
Antenna factor calibration
Cable loss calibration
Pre Amplifier Gain calibration
RCV/SPA specification
Antenna Factor Interpolation for Frequency
Site imperfection
Mismatch
combined standard uncertainty Uc(y)
Measuring uncertainty for a level of confidence
of 95%
U=2Uc(y)
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
0.08
0.11
0.63
0.43
0.90
0.24
2.42
(30MHz ~ 1000MHz)
x
Contribution
u  xi 
Uncertainty of i
Probability
dB
Distribution
0.19
Normal(k=2)
1.07
Normal(k=2)
0.23
Normal(k=2)
0.22
Normal(k=2)
2.50
Rectangular
1.00
Rectangular
1.81
Rectangular
+0.42/-0.44
U-shaped
1.45
u  xi 
0.10
0.54
0.12
0.11
0.72
0.29
1.05
0.30
2.90
Page Number
: 19 of 20
Issued Date
: Dec. 05, 2005
FCC DoC TEST REPORT
9.
Report No. : FD5NS006
Certificate of NVLAP Accreditation
SPORTON International Inc.
TEL : 886-2-2696-2468
FAX : 886-2-2696-2255
Page Number
: 20 of 20
Issued Date
: Dec. 05, 2005
Download