Annex No. 2 to: IECEx ULD 06.0017X Manufacturer: Detector Electronics Corporation Electrical apparatus: Multispectrum IR Flame Detectors models X3301, X3302 and X33AF Nomenclature for type X3301 (or X33AF) abcde: where a = Enclosure material: A = Aluminium b Type, and number of threaded locations: S = Stainless steel = 4M = 4 Port, Metric M25 4N = 4 Port, ¾” NPT c = Outputs: 11 = Relay 13 = Relay & 4-20mA 14 = LON Eagle Quantum Premier 15 = Relay & Pulse 16 = Addressable module (third party type, for Ex d version only) 17 = RS485 19 = POWER LOOP (AUTRONICA ONLY) 21 = Relay Automotive 22 = EQP Automotive 23 = Relay / 4-20mA & HART d = Approvals: A = FM & CSA B = Brazil C = CSA E = ATEX/CE R = RUSSIA T = SIL2/FM/CSA/ATEX/CE U = UKRAINE V = Vds/ATEX/CE/CNBOP W = FM/CSA/ATEX/CE Y = CHINA e = Classification: 1 = DIVISION/ZONE Ex d e 2 = DIVISION/ZONE Ex d Nomenclature for type X3302 abcde: where: a = Enclosure material: A = Aluminium b Type, and number of threaded locations: S = Stainless steel = 4M = 4 Port, Metric M25 4N = 4 Port, ¾” NPT c = Outputs: 11 = Relay 13 = Relay & 4-20mA 14 = LON Eagle Quantum Premier 15 = Relay & Pulse 16 = Addressable module (third party type, for Ex d version only) 17 = RS485 Certificate: IECEx ULD 06.0017X Report: 139309-02 This Annex is valid only in combination with certificate IECEx ULD 06.0017X and may only be reproduced in its entirety and without any change Annex No. 2 to: IECEx ULD 06.0017X Manufacturer: Detector Electronics Corporation Electrical apparatus: Multispectrum IR Flame Detectors models X3301, X3302 and X33AF 23 = Relay / 4-20mA & HART Page 1 of 3 Nomenclature for type X3302 abcde (continued): d = Approvals: E = ATEX/CE T = SIL2/FM/CSA/ATEX/CE V = Vds/ATEX/CE/CNBOP W = FM/CSA/ATEX/CE e = Classification: 1 = DIVISION/ZONE Ex d e 2 = DIVISION/ZONE Ex d Note: The name and address of the manufacturer shall always be marked on the label. Temperature range for X3301, X3302 and X33AF. The relation between ambient temperature and the assigned temperature class is as follows: For Ex d e: Ambient temperature range Temperature class -50°C to +60°C T6 -50°C to +75°C T5 For Ex d: Ambient temperature range -55°C to +60°C -55°C to +75°C Temperature class T6 T5 Electrical data Rated voltage: Power consumption: 18- 30Vdc max. 17W Optional third party addressable module: Rated voltage: 30Vdc Rated current: 30mA Installation instructions The field wiring connections in the terminal compartment are ATEX certified and accept wiring diameters from 12 AWG to 22 AWG. The Multispectrum infrared (IR) flame detectors type X3301, X3302 and X33AF shall be installed according to the instructions given by the manufacturer. The cable entry devices shall be certified in type of explosion protection flameproof enclosure “d” for use with the terminal compartment in type of explosion protection flameproof enclosure “d”, or in type of explosion protection increased safety “e” for use with the terminal compartment in type of explosion protection increased safety “e”. They shall be IP66 rated, suitable for the conditions of use and correctly installed. Unused entries shall be closed with suitable certified blanking elements. The metal housing for the Multispectrum infrared (IR) flame detector types X3301, X3302 and X33AF, must be electrically connected to earth ground. For ambient temperatures below –10 C and above +60 C use field wiring suitable for both minimum and maximum ambient temperature. Certificate: IECEx ULD 06.0017X Report: 139309-02 This Annex is valid only in combination with certificate IECEx ULD 06.0017X and may only be reproduced in its entirety and without any change Annex No. 2 to: IECEx ULD 06.0017X Manufacturer: Detector Electronics Corporation Electrical apparatus: Multispectrum IR Flame Detectors models X3301, X3302 and X33AF Routine tests Routine tests for dielectric strength according to IEC 60079-7 cl. 7.1 are required for the increased safe ‘e’ terminal compartment circuits. Page 2 of 3 Documents: Description: Drawing No.: Rev. Level: Date: Drawing, design reference X3301, X3302 and X33AF “DEMKO” Enclosure Machined SS 007288-001 P 2010-04-12 007247-002 G 2006-06-06 Enclosure, AL, D.C. (Mach) 008086-XXX C 2008-07-29 Bulkhead Mach SST Herm Seal 010069-XXX A 2009-09-17 Bulkhead Mach AL Herm Seal 010068-XXX A 2009-09-17 Heatsink AL MACH ATEX 010056-001 C 2010-04-12 Window Sapphire Cover Elect Module 010057-XXX 010055-XXX C D 2010-04-12 2010-04-12 Retainer Ring Mach FRGD AL 010206-001 A 2009-08-25 Installation Instructions 95-8527 / 95-8576 / 95-8625 4/10 - Special conditions for safe use: The front window assembly contains a special cemented joint construction. In accordance with IEC60079-1 clause 5.1.c, all inspections, repair and/or adjustments to this front window assembly, shall be done by Detector Electronics Corporation only. The EOL resistor can only be used within the flameproof terminal compartment. The Multispectrum infrared (IR) flame detector types X3301, X3302 and X33AF are to be installed in places where there is a low risk of mechanical damage. Additional information The Multispectrum infrared (IR) flame detector types X3301, X3302 and X33AF have in addition passed the tests for Ingress Protection to IP66 in accordance with IEC60529:1991/A1 2001. Certificate: IECEx ULD 06.0017X Report: 139309-02 This Annex is valid only in combination with certificate IECEx ULD 06.0017X and may only be reproduced in its entirety and without any change Annex No. 2 to: IECEx ULD 06.0017X Manufacturer: Detector Electronics Corporation Electrical apparatus: Multispectrum IR Flame Detectors models X3301, X3302 and X33AF Page 3 of 3 Certificate: IECEx ULD 06.0017X Report: 139309-02 This Annex is valid only in combination with certificate IECEx ULD 06.0017X and may only be reproduced in its entirety and without any change