Our underground distribution systems are modern distribution systems also suitable for underground installation with flooding protection. We produce and deliver solutions that urban landscapes in the age of contemporary marketplace design and urban renewal. Underground distribution systems Underground distribution system | Underground distribution system with electrical socket combinations Page Underground distribution system with electrical socket combinations 3–8 EK 600 | EK 800 | with swivel cover | general information 9–20 EK 800 | with configurator 21–28 EK 600 | with configurator 29–31 EK 818 | with swivel cover 32 EK 809 | EK 909 general information 33 EK 809 | with removable cover 34 EK 909 | with removable cover, with terminal compartment for back-up fuse 35–38 EK 809 | EK 909 | configuration examples Underground distribution systems for power supply and telecommunication EK 880 | with horizontally swivelling technical compartment 39–41 Underground distribution systems for customised component integration 42–43 EK 368 | housing with NH00 isolator 44–46 EK 838 | with integrated cable outlet in cast iron cover 47–48 EK 383 | Motorway roadside emergency telephone manhole 49 References 2 Underground distribution system | Underground distribution system with electrical socket combinations Langmatz underground systems: Modular construction Low weight Produced using injection moulding for more stability and safety High-quality, recyclable polycarbonate 50 years of experience in plastics processing Construction on top of existing cable routes Individual construction of wall elements Different covers depending on the installation situation High temperature resistance Surface finish with hot mix and mastic asphalt non-critical Rot proof High chemical durability 3 Underground distribution system | Underground distribution system with electrical socket combinations 4 Underground distribution system | Underground distribution system with electrical socket combinations What is so special about this underground distribution system … … Advantages that convince! Modular electrical socket combination, integrated into submersion cover with flooding protection Dirt-resistant locking mechanism with forced opening in the event of dirt ingress or icing Cable outlet on the left-hand and right-hand side of the locking mechanism, independent operation Fresh water connections EK 600 | coupling up to 2 x 1/2–1" EK 800 | coupling up to 4 x 1/2–1" 5 Underground distribution system | Underground distribution system with electrical socket combinations Even more advantages that impress �Swivel cover, easily accessible due to two stainless steel pneumatic springs �IP68 connection housing acc. to DIN EN 60 529 with NH-00 fixture as back-up fuse or as terminal box �Modular electrical socket combination, integrated into submersion cover with flooding protection �Clearly defined area for the installation of an expansion joint �Clear, logical assignment of the circuit breaker/residual current device to the sockets �One miniature circuit breaker per socket �Sheet metal parts produced with modern sheet metal bending technology �Step protection �Fresh water connections: - Supply: 1" - Outlet: 1/2" - Coupling 1/2–1" - + 1 x 2" waste water �Installation of the water connections in the area of the optional electric heater �Dirt-resistant locking mechanism with forced opening in the event of dirt ingress or icing. �Lockable �Cable outlet on the left-hand and right-hand side of the locking mechanism, independent operation �Centred locking mechanism for optimum application of force �All steel parts in stainless steel 6 Underground distribution system | Underground distribution system with electrical socket combinations Individual configuration with: Modular electrical socket combinations Integrated into submersion cover with flooding protection Configuration example (see configurator) Connecting housing IP68 acc. to DIN EN 60 529 With NH-00 back-up fuse or terminal block Type: EK 664 Cover heater 180 W Thermostat Fresh water 2 x Quick disconnect, type GK 1/2–1" (EK 600) or 4 x Quick disconnect, type GK 1/2–1" (EK 800) Fresh water shut-off valve DVGW-KFR (combined free-flow/check valve) The operating company is responsible for check valves Optional: - Shut-off and drainage hydrant - Water meter Waste water Storz 52-C 2" DIN 14037 Quick disconnects for waste water Compressed air Upon inquiry 7 Underground distribution system | Underground distribution system with electrical socket combinations Locking mechanism | Underground distribution system EK 600 | EK 800 Opening mechanism protected via separate locking flap � Locking mechanism with hexagon socket spanner for easy operation Cable outlet and lock spring � Enlarged cable outlet, for cables up to Ø 60 mm � New locking system patented by Langmatz 8 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system EK 800 | with swivel cover Area of application The equipment is integrated into the polycarbonate manhole. Systems for power supply, fresh water and waste water can be integrated. Equipment is tailored to your requirements, safely protected, and operated hidden in the ground. EK 800 Inside width: 550 x 800 mm Overall outer dimensions: 825 x 1050 mm Overall height without NH-00 back-up fuse and without step protection: approx. 625 or 845 mm Overall height with NH-00 back-up fuse and with step protection: approx. 1065 mm Paveable stainless steel cover; up to D 400 according to DIN EN 124 Paving height: Stainless steel manhole frame Maximum fuse protection: 100 A Connected load of the optional electric heater: 180 W Electric distributor protection class closed: IP58 acc. to DIN EN 60 529 open: IP54 acc. to DIN EN 60 529 Side view 65 mm Front view Top view (paveable cover) 9 Underground distribution system | Underground distribution system with electrical socket combinations Manhole Configurator EK 800 Item No 70 070 8000 / 001 Change index: 3 10 Underground distribution system | Underground distribution system with electrical socket combinations 3. Manhole body Manhole height Description Paveable Cover Item No: Chequered Stud Plate Cover Item No: Concrete-Lined Cover Item No: Height 1 = 625 mm - Electrical installation kit: no restrictions - No step protection possible - No water and/or waste water possible - No main fuse and/ or terminal unit possible Height 3 = 1065 mm - Elec. installation kit up to max. 32 A socket only for var. 1; 2; 10 - No step protection possible - No water and/or waste water possible - No main fuse and/ or terminal unit possible Height 2 = 845 mm Visual illustration No restrictions 06 800 0501 06 800 0501/001 06 800 0501/002 1 x size 220 frame 1 x size 220 frame 1 x size 220 frame 06 800 0502 06 800 0502/001 06 800 0502/002 2 x size 220 frame 2 x size 220 frame 2 x size 220 frame 06 800 0503 06 800 0503/001 06 800 0503/002 3 x size 220 frame 3 x size 220 frame 3 x size 220 frame = Please mark requested variant. 4. Test category (please make a selection) Test category Item No: DIN EN124-B125 06 800 0053 DIN EN124-D400 06 800 0052 Selection 11 4 Underground distribution system | Underground distribution system with electrical socket combinations 5. Assembly, operation and maintenance guidelines (please make a selection) Language Item No: Selection German 70 070 0901 / 000 English French 70 070 0901 / 001 70 070 0901 / 002 Russian 70 070 0901 / 012 6. Electrical installation kit (please make a selection) Visual illustration 1.1 1.2 1.3 1.4 1.5 Configuration 16 x Schuko 4 x 16 A 5-pole 0 x 32 A 5-pole 16 x Schuko 3 x 16 A 5-pole 1 x 32 A 5-pole 16 x Schuko 2 x 16 A 5-pole 2 x 32 A 5-pole 16 x Schuko 1 x 16 A 5-pole 3 x 32 A 5-pole 16 x Schuko 0 x 16 A 5-pole 4 x 32 A 5-pole Cable cross-section 16 mm² max. 80 A 06 800 0301 16 mm² max. 80 A 06 800 0302 16 mm² max. 80 A 06 800 0303 16 mm² max. 80 A 06 800 0304 16 mm² max. 80 A 06 800 0305 Series fuse rated current Item No: Selection 12 5 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 2.1 2.2 2.3 2.4 2.5 2.6 2.7 3.1 3.2 3.3 Configuration 8 x Schuko 6 x 16 A 5-pole 0 x 32 A 5-pole 8 x Schuko 5 x 16 A 5-pole 1 x 32 A 5-pole 8 x Schuko 4 x 16 A 5-pole 2 x 32 A 5-pole 8 x Schuko 3 x 16 A 5-pole 3 x 32 A 5-pole 8 x Schuko 2 x 16 A 5-pole 4 x 32 A 5-pole 8 x Schuko 1 x 16 A 5-pole 5 x 32 A 5-pole 8 x Schuko 0 x 16 A 5-pole 6 x 32 A 5-pole 8 x Schuko 2 x 16 A 5-pole 0 x 32 A 5-pole 2 x 63 A 5-pole 8 x Schuko 1 x 16 A 5-pole 1 x 32 A 5-pole 2 x 63 A 5-pole 8 x Schuko 0 x 16 A 5-pole 2 x 32 A 5-pole 2 x 63 A 5-pole Cable Series fuse Item No: cross-secrated current tion 16 mm² max. 80 A 06 800 0306 16 mm² max. 80 A 06 800 0307 16 mm² max. 80 A 06 800 0308 16 mm² max. 80 A 06 800 0309 16 mm² max. 80 A 06 800 0310 16 mm² max. 80 A 06 800 0311 25 mm² max. 100 A 06 800 0312 25 mm² max. 100 A 06 800 0313 25 mm² max. 100 A 06 800 0314 25 mm² max. 100 A 06 800 0315 Selection 13 6 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 4.1 4.2 4.3 4.4 4.5 5.1 5.2 5.3 Cable Series fuse Item No: cross-secrated current tion 25 mm² max. 100 A 06 800 0316 Configuration 8 x Schuko 4 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 3 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 2 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 1 x 16 A 5-pole 3 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 0 x 16 A 5-pole 4 x 32 A 5-pole 1 x 63 A 5-pole 16 x Schuko 2 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 16 x Schuko 1 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 16 x Schuko 0 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole 25 mm² max. 100 A 06 800 0317 25 mm² max. 100 A 06 800 0318 25 mm² max. 100 A 06 800 0319 25 mm² max. 100 A 06 800 0320 25 mm² max. 100 A 06 800 0321 25 mm² max. 100 A 06 800 0322 25 mm² max. 100 A 06 800 0323 Selection 14 7 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 6.1 6.2 6.3 6.4 7.1 7.2 7.3 Configuration 12 x Schuko 3 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 12 x Schuko 2 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 12 x Schuko 1 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole 12 x Schuko 0 x 16 A 5-pole 3 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 6 x 16 A 3-pole 2 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 6 x 16 A 3-pole 1 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 8 x Schuko 6 x 16 A 3-pole 0 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole Cable Series fuse Item No: cross-secrated current tion 25 mm² max. 100 A 06 800 0324 25 mm² max. 100 A 06 800 0325 25 mm² max. 100 A 06 800 0326 25 mm² max. 100 A 06 800 0327 25 mm² max. 100 A 06 800 0328 25 mm² max. 100 A 06 800 0329 25 mm² max. 100 A 06 800 0330 Selection 15 8 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 8.1 8.2 8.3 8.4 8.5 9.1 9.2 9.3 Configuration 6 x 16 A 3-pole 4 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 6 x 16 A 3-pole 3 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 6 x 16 A 3-pole 2 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole 6 x 16 A 3-pole 1 x 16 A 5-pole 3 x 32 A 5-pole 1 x 63 A 5-pole 6 x 16 A 3-pole 0 x 16 A 5-pole 4 x 32 A 5-pole 1 x 63 A 5-pole 6 x 16 A 3-pole 2 x 16 A 5-pole 0 x 32 A 5-pole 2 x 63 A 5-pole 6 x 16 A 3-pole 1 x 16 A 5-pole 1 x 32 A 5-pole 2 x 63 A 5-pole 6 x 16 A 3-pole 0 x 16 A 5-pole 2 x 32 A 5-pole 2 x 63 A 5-pole Cable Series fuse Item No: cross-secrated current tion 25 mm² max. 100 A 06 800 0331 25 mm² max. 100 A 06 800 0332 25 mm² max. 100 A 06 800 0333 25 mm² max. 100 A 06 800 0334 25 mm² max. 100 A 06 800 0335 25 mm² max. 100 A 06 800 0336 25 mm² max. 100 A 06 800 0337 25 mm² max. 100 A 06 800 0338 Selection 16 9 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 10.1 10.2 10.3 10.4 10.5 10.6 10.7 11 Without electrical installation/ without submersion cover Configuration Cable Series fuse Item No: cross-secrated current tion 16 mm² max. 80 A 06 800 0339 6 x 16 A 3-pole 6 x 16 A 5-pole 0 x 32 A 5-pole 6 x 16 A 3-pole 16 mm² max. 80 A 5 x 16 A 5-pole 1 x 32 A 5-pole 6 x 16 A 3-pole 16 mm² max. 80 A 4 x 16 A 5-pole 2 x 32 A 5-pole 6 x 16 A 3-pole 16 mm² max. 80 A 3 x 16 A 5-pole 3 x 32 A 5-pole 6 x 16 A 3-pole 16 mm² max. 80 A 2 x 16 A 5-pole 4 x 32 A 5-pole 6 x 16 A 3-pole 25 mm² max. 100 A 1 x 16 A 5-pole 5 x 32 A 5-pole 6 x 16 A 3-pole 25 mm² max. 100 A 0 x 16 A 5-pole 6 x 32 A 5-pole Earthing and mounting set for version without electrical installation kit. CAUTION! Damper settings corresponds to the assembly condition with electrical fixtures. Selection 06 800 0340 06 800 0341 06 800 0342 06 800 0343 06 800 0344 06 800 0345 06 800 0300 17 10 Underground distribution system | Underground distribution system with electrical socket combinations 7. Submersion cover with mounting plate for individual configuration by customers Item No: Yes Selection 06 800 0346 8. Connection cable for electrical installation kit Cable cross-section based on list of electrical installation kit Not in connection with the main fuse Item No: Selection 5 x 35 mm² connection; 3 metres 06 800 0090 4 x 35 mm² connection; 3 metres 06 800 0091 5 x 25 mm² connection; 3 metres 06 800 0092 4 x 25 mm² connection; 3 metres 06 800 0093 5 x 16 mm² connection; 3 metres 06 800 0094 4 x 16 mm² connection; 3 metres 06 800 0095 18 11 Underground distribution system | Underground distribution system with electrical socket combinations 9. Main fuse and/or terminal unit (optional at height 3 = 1065 mm) Cable cross-section based on list of electrical installation kit Visual illustration Selection Description Item No: Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 5 x 35 mm² Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 4 x 35 mm² Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 5 x 25 mm² Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 4 x 25 mm² Main fuse NH-00 max. 80 A/ with 3.5 m connection cable 5 x 16 mm² Main fuse NH-00 max. 80 A/ with 3.5 m connection cable 4 x 16 mm² IP68 housing with 16–35 mm² terminal 35 mm² connection cable for elec. installation kit, Ø34–45 mm (not included with delivery) IP68 housing with 16–35 mm² terminal 25 mm² connection cable for elec. installation kit, Ø34–45 mm (not included with delivery) IP68 housing with 16–35 mm² terminal block 16 mm² cable for elec. installation kit, Ø34– 45 mm (not included with delivery) 06 664 0550 06 664 0551 06 664 0552 06 664 0553 06 664 0554 06 664 0555 06 664 0556 06 664 0557 06 664 0558 10. Step protection (optional at height 3 = 1065 mm) Item No: Standard metal 06 800 0051 Plastic 06 800 0056 Selection 11. Cover lock heater (optional) Item No: Yes Selection 06 800 0060 12 19 Underground distribution system | Underground distribution system with electrical socket combinations 12. Waste water 2" Storz coupling (optional at height 3 = 1065 mm) Not in connection with the main fuse or terminal unit Item No: Yes Selection 06 800 0059 13. Fresh water 1/2"–1" quick disconnect coupling (optional at height 3 = 1065 mm) Visual illustration Description Item No 1 x Fresh water connection 700707901 2 x Fresh water connection 700707902 3 x Fresh water connection 700707903 4 x Fresh water connection 700707904 1 x Fresh water connection with main hydrant 700707905 2 x Fresh water connection with main hydrant 700707906 3 x Fresh water connection with main hydrant 700707907 4 x Fresh water connection with main hydrant 700707908 1 x Fresh water connection with water meter 700707909 2 x Fresh water connection with water meter 700707910 3 x Fresh water connection with water meter 700707911 4 x Fresh water connection with water meter 700707912 1 x Fresh water connection with main hydrant and water meter 2 x Fresh water connection with main hydrant and water meter 3 x Fresh water connection with main hydrant and water meter 4 x Fresh water connection with main hydrant and water meter 700707913 Selection 700707914 700707915 700707916 14. Accessories Visual illustration Description Item No Hexagonal socket spanner SW14 T-shape 700699600 Valve key for main hydrant T-shape 700710500 13 Selection 20 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system EK 600 | with swivel cover Area of application The equipment is integrated into the polycarbonate manhole. Systems for power supply, fresh water and waste water can be integrated. Equipment is tailored to your requirements, safely protected, and operated hidden in the ground. EK 600 Inside width: 400 x 650 mm Overall outer dimensions: 683 x 900 mm Overall height without NH-00 back-up fuse and without step protection: approx. 640 or 860 mm Overall height with NH-00 back-up fuse and with step protection: approx. 1080 mm Paveable stainless steel cover; up to D 400 according to DIN EN 124 Paving height: Stainless steel manhole frame Maximum fuse protection: 100 A Connected load of the optional electric heater: 180 W Electric distributor protection class closed: IP58 acc. to DIN EN 60 529 open: IP54 acc. to DIN EN 60 529 Side view 65 mm Front view Top view (paveable cover) 21 Underground distribution system | Underground distribution system with electrical socket combinations Manhole Configurator EK 600 Item No 70 071 7500 / 001 Change index: 2 22 Underground distribution system | Underground distribution system with electrical socket combinations 3. Manhole body Manhole height Description Paveable Cover Item No: Chequered Stud Plate Cover Item No: Concrete-Lined Cover Item No: Height 1 = 640 mm - Electrical installation kit: no restrictions - No step protection possible - No water and/or waste water possible - No main fuse and/ or terminal unit possible Height 3 = 1080 mm - Elec. installation kit up to max. 32 A socket only for var. 2; 3; 4; 7; 8 - No step protection possible - No water and/or waste water possible - No main fuse and/ or terminal unit possible Height 2 = 860 mm Visual illustration No restrictions 06 600 0501 06 600 0501/001 06 600 0501/002 1 x size 220 frame 1 x size 220 frame 1 x size 220 frame 06 600 0502 06 600 0502/001 06 600 0502/002 2 x size 220 frame 2 x size 220 frame 2 x size 220 frame 06 600 0503 06 600 0503/001 06 600 0503/002 3 x size 220 frame 3 x size 220 frame 3 x size 220 frame = Please mark requested variant. 4. Test category (please make a selection) Test category Item No: DIN EN 124-B125 06 800 0053 DIN EN 124-D400 06 800 0052 Selection 23 4 Underground distribution system | Underground distribution system with electrical socket combinations 5. Assembly, operation and maintenance guidelines (please make a selection) Language Item No: Selection German 70 070 0901 / 000 English French 70 070 0901 / 001 70 070 0901 / 002 Russian 70 070 0901 / 012 Other languages available on request. 6. Electrical installation kit (please make a selection) Visual illustration 1.1 1.2 2.1 2.2 2.3 3.1 3.2 4.1 4.2 4.3 4.4 Cable Series fuse Item No: cross-secrated current tion 25 mm² max. 100 A 06 600 0301 Configuration 4 x Schuko 1 x 16 A 5-pole 1 x 63 A 5-pole 4 x Schuko 1 x 32 A 5-pole 1 x 63 A 5-pole 4 x Schuko 2 x 16 A 5-pole 0 x 32 A 5-pole 4 x Schuko 1 x 16 A 5-pole 1 x 32 A 5-pole 4 x Schuko 0 x 16 A 5-pole 2 x 32 A 5-pole 8 x Schuko 1 x 16 5-pole 8 x Schuko 1 x 32 A 5-pole 3 x 16 A 5-pole 0 x 32 A 5-pole 1 x 16 A 5-pole 2 x 32 A 5-pole 2 x 16 A 5-pole 1 x 32 A 5-pole 0 x 16 A 5-pole 3 x 32 A 5-pole 25 mm² max. 100 A 06 600 0302 16 mm² max. 80 A 06 600 0303 16 mm² max. 80 A 06 600 0304 16 mm² max. 80 A 06 600 0305 16 mm² max. 80 A 06 600 0306 16 mm² max. 80 A 06 600 0307 16 mm² max. 80 A 06 600 0308 16 mm² max. 80 A 06 600 0309 16 mm² max. 80 A 06 600 0310 16 mm² max. 80 A 06 600 0311 Selection 24 5 Underground distribution system | Underground distribution system with electrical socket combinations Visual illustration 5.1 2 x 16 A 5-pole 0 x 32 A 5-pole 1 x 63 A 5-pole 1 x 16 A 5-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 0 x 16 A 5-pole 2 x 32 A 5-pole 1 x 63 A 5-pole 2 x 16 A 3-pole 1 x 16 A 5-pole 1 x 63 A 5-pole 2 x 16 A 3-pole 1 x 32 A 5-pole 1 x 63 A 5-pole 2 x 16 A 3-pole 2 x 16 A 5-pole 0 x 32 A 5-pole 2 x 16 A 3-pole 1 x 16 A 5-pole 1 x 32 A 5-pole 2 x 16 A 3-pole 0 x 16 A 5-pole 2 x 32 A 5-pole 4 x 16 A 3-pole 1 x 16 A 5-pole 4 x 16 A 3-pole 1 x 32 A 5-pole 5.2 5.3 6.1 6.2 7.1 7.2 7.3 8.1 8.2 9 Configuration Without electrical Installation/ without submersion cover Cable Series fuse Item No: cross-secrated current tion 25 mm² max. 100 A 06 600 0312 25 mm² max. 100 A 06 600 0313 25 mm² max. 100 A 06 600 0314 25 mm² max. 100 A 06 600 0315 25 mm² max. 100 A 06 600 0316 16 mm² max. 80 A 06 600 0317 16 mm² max. 80 A 06 600 0318 16 mm² max. 80 A 06 600 0319 16 mm² max. 80 A 06 600 0320 16 mm² max. 80 A 06 600 0321 Earthing and mounting set for version without electrical installation kit. CAUTION! Damper settings corresponds to the assembly condition with electrical fixtures. 06 800 0300 Selection 7. Submersion cover with mounting plate for individual configuration by customers Item No: Yes Selection 06 600 0366 25 6 Underground distribution system | Underground distribution system with electrical socket combinations 8. Connection cable for electrical installation kit Cable cross-section based on list of electrical installation kit cable lengths from cable gland (electrical installation kit) to EK313 strain relief: 1300 mm Not in connection with the main fuse or terminal unit Item No: Selection 5 x 25 mm² connection; 3 metres 06 800 0092 4 x 25 mm² connection; 3 metres 06 800 0093 5 x 16 mm² connection; 3 metres 06 800 0094 4 x 16 mm² connection; 3 metres 06 800 0095 9. Main fuse and/or terminal unit (optional at height 3 = 1080 mm) Cable cross-section based on list of electrical installation kit cable lengths from main fuse cable gland to EK313 strain relief: 1300 mm Not in connection with fresh water or waste water Visual illustration Description Item No: Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 5 x 25 mm² Main fuse NH-00 max. 100 A/ with 3.5 m connection cable 4 x 25 mm² Main fuse NH-00 max. 80 A/ with 3.5 m connection cable 5 x 16 mm² Main fuse NH-00 max. 80 A/ with 3.5 m connection cable 4 x 16 mm² IP68 housing with 16–35 mm² clamp for connection cable, Ø 34–45 mm (without connec- 06 664 0652 Selection 06 664 0653 06 664 0654 06 664 0655 06 664 0657 tion cable) Cable for elec. installation kit 25 mm² IP68 housing with 16–35 mm² terminal block 06 664 0658 for connection cable, Ø 27–34.5 mm (without connection cable) Cable for elec. installation kit 16 mm² 10. Step protection (optional at height 3 = 1080 mm) Item No: Yes 06 600 0051 Selection 26 Underground distribution system | Underground distribution system with electrical socket combinations 11. Cover lock heater (optional) Item No: Yes Selection 06 600 0060 12. Waste water 2" Storz coupling (optional at height 3 = 1080 mm) Not in connection with the main fuse or terminal unit Item No: Yes Selection 06 600 0059 13. Fresh water 1/2"–1" quick disconnect coupling (optional at height 3 = 1080 mm) Not in connection with the main fuse or terminal unit Visual illustration Description Item No 1 x Fresh water connection 700716504 2 x Fresh water connection 700716508 Selection 1 x Fresh water connection with main hy700716502 drant 2 x Fresh water connection with main hy700716506 drant 1 x Fresh water connection with water meter 700716503 2 x Fresh water connection with water meter 700716507 1 x Fresh water connection with main hydrant and water meter 2 x Fresh water connection with main hydrant and water meter 700716501 700716505 27 Underground distribution system | Underground distribution system with electrical socket combinations 14. Accessories Visual illustration Description Item No Hexagonal socket spanner SW14 T-shape 700699600 Valve key for main hydrant T-shape 700710500 Selection 28 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system EK 818 (Indoor) | with swivel cover (made of cast iron) Area of application The equipment is integrated into the polycarbonate manhole. Systems for power supply, fresh water and waste water can be integrated. Equipment is tailored to your requirements, safely protected, and operated hidden in the ground. Features Swivel cover Individual configuration with: - Socket combinations - Cable connection box - Fresh water and/or waste water connection EK 818 Inside width: 550 x 800 mm Outer dimensions: 940 x 700 mm Closed height: 1165 mm with NH-00 back-up fuse 945 mm without NH-00 back-up fuse Open height: 2015 mm with NH-00 back-up fuse 1795 mm without NH-00 back-up fuse Cast iron cover B 125 / D 400 acc. to DIN EN 124 Manhole frame Stainless steel Distributor protection class IP44 acc. to DIN EN 60 529 NH connection housing IP68 acc. to DIN EN 60 529 Dimensions Side view Front view 29 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system EK 818 (Indoor) | with swivel cover Mode of operation Unlocking the cover Folding the cover open into vertical position – supported by two pneumatic springs Automatic safety cover latching with the cover open (Step protection) Connecting the lines to the distributor outlets, unlocking the safety cover and closing the cover Routing the lines through the inlet openings in the cover Locking the cover (protection against unauthorized access) Waste For current draw from a distributor underneath the cover Fresh water 30 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system EK 818 (Indoor) | with swivel cover Individual configuration: Electrical socket combinations Splashproof IP 44 Configuration example Technical data EK 818 Area of application Indoor, outdoor area Protection class IP 44 for distributor Network configuration TN-S system Configuration 1 housing (PBT-PC blend) with window B54.05 1 housing (PBT-PC blend) with window B53.01 7 single phase sockets blue, 2 ABL17 sockets 3/16 A, 230 V, 6H, blue, straight 9 circuit breakers, 1-pole, B, 16 A, 10 kA 1 residual current device, 4-pole, B, 63 A, 30 mA 1 clamp block 2 x 5 x 25 mm² 1 line H07 RN-F 5 x 16 mm², 2.5 m supply line 1 line H07VK, 1 x 10 mm², 0.5 m overall line 1 screw connection M40 /lg M.D. + lock nut 1 screw connection M20 /lg M.D. + lock nut Connecting housing IP68 acc. to DIN EN 60 529 With NH-00 back-up fuse Type: EK 664 Fresh water 2 x Quick disconnect, type GK 1/2–1" 4 x Quick disconnect, type GK 1/2–1" Waste water Storz 52-C 2" DIN 14037 quick disconnects for waste water Compressed air Upon inquiry 31 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | EK 909 | with removable cover Removable cover, supported by pneumatic spring Cover lockable in closed condition Individual configuration with socket combinations General advantages, EK 809 | EK 909 Socket distributor can be replaced Sturdy locking mechanism with proven round thread Safety lock with "push-open function" Automatic latching in extended position Easy installation, operation and maintenance Advantages, EK 909 Back-up fuse can be accommodated Back-up fuse in IP68 connection housing with flooding protection acc. to DIN EN 60 529 Telescopic rail system for connection housing User-assigned accessibility via separate cover 32 Underground distribution system | 4Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | with removable cover Area of application The equipment is integrated into the polycarbonate manhole Systems for power supply can be integrated. Equipment is tailored to your requirements, safely protected, and accommodated hidden in the ground. Cover EK 809 cast iron cover Cover EK 809 paveable Inside widths 550 x 550 mm 550 x 550 mm Outer dimensions: 700 x 700 mm 694 x 814 mm Closed height: 1040 mm 1214 mm Open height: 1430 mm 1677 mm Paving height: manhole cover: Manhole frame: Galvanized steel Stainless steel Distributor protection class IP54 acc. to DIN EN 60 529 IP54 acc. to DIN EN 60 529 45 mm B 125 / D 400 acc. to DIN EN 124 D 400 acc. to DIN EN 124 33 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 909 | with removable cover Area of application The equipment is integrated into the polycarbonate manhole Systems for power supply can be integrated. Equipment is tailored to your requirements, safely protected, and accommodated hidden in the ground Additional connection housing for NH back-up fuse Cover EK 909 cast iron cover/ chequered stud plate Stainless steel cover EK 909 paveable Inside width: 550 x 800 mm 550 x 800 mm Outer dimensions: 710 x 940 mm 710 x 940 mm Closed height: 1035 mm 1214 mm Open height: 1433 mm 1677 mm Paving height: Manhole frame: Galvanized steel Stainless steel Distributor protection class IP54 acc. to DIN EN 60 529 IP54 acc. to DIN EN 60 529 NH connection housing IP68 acc. to DIN EN 60 529 IP68 acc. to DIN EN 60 529 45 mm 34 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | EK 909 | with removable cover Configuration examples Distributor B780723 – rubber free-standing distributor, black front 8x single phase socket, blue, IP54 3x ABL17 socket 3/16 A 230 V, 6H, blue straight left 1 auxiliary window B78/12TE 2x ABL17 socket 5/32 A 400 V. 6H red, straight rear 4x single phase socket, blue, IP54 2x ABL17 socket 5/32 A 400 V. 6H red, straight 4x circuit breakers, 3-pole B 32 A 10 kA right 2x auxiliary windows B78/12TE 15x circuit breakers, 1-pole B 16 A 10 kA 2x residual current device 4P / 80 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 35mm² 1 M50 screw connection 1 line H07 RN-F 5 x 35 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 2x clamp 12x10 mm² Distributor B780710 front left 2x auxiliary windows B78/12TE rear 1 ABL17 socket 5/16 A, 400 V, 6H, red, straight right 2x single phase socket, blue, IP54 2x circuit breakers, 1-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 16 A 10 kA 1 residual current device 4P / 40 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 25 mm² 1 M40 screw connection 1 line H07 RN-F 5 x 16 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m 35 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | EK 909 | with removable cover Configuration examples Distributor B780712 front left rear 2x auxiliary windows B78/12TE right 6x ABL17 socket 3/16 A, 230 V, 6H, blue, straight 6x circuit breakers, 1-pole B 16 A 10 kA 1 residual current device 4P / 40 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 25 mm² 1 M40 screw connection 1 line H07 RN-F 5 x 16 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m Distributor B780713 front 2x auxiliary windows B78/12TE left rear 7x single phase socket, blue, IP54 right 9x circuit breakers, 1-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 32 A 10 kA 2x ABL17 socket 3/16 A, 230 V, 6H, blue, straight 1 ABL17 socket 5/16 A, 400 V, 6H, red, straight, 72x65 mm 1 ABL17 socket 5/32 A, 400 V, 6H, red, straight 1 residual current device 4P / 40 A / 30 mA pulse current sensitive 1 residual current device 4P / 63 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 25 mm² 1 M40 screw connection 1 line H07 RN-F 5 x 16 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m 2x clamp 12x10 mm² 36 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | EK 909 | with removable cover Configuration examples Distributor B780714 front left rear 2x auxiliary windows B78/12TE right 2x circuit breakers, 1-pole B 16 A 10 kA 2x ABL17 socket 3/16 A, 230 V, 6H, blue, straight 1 ABL17 socket 5/16 A, 400 V, 6H, red, straight 1 circuit breakers, 3-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 32 A 10 kA 1 residual current device 4P / 63 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 25 mm² 1 M40 screw connection 1 line H07 RN-F 5 x 16 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m Distributor B780715 left front 2x auxiliary windows B78/12TE 4x circuit breakers, 1-pole B 16 A 10 kA 1 ABL17 socket 5/16 A, 400 V, 6H, red, straight rear 3x single phase socket, blue, IP54 1 ABL17 socket 5/63 A, 400 V, 6H, red, straight right 1 ABL17 socket 3/16 A, 230V, 6H, blue, straight 1 ABL17 socket 5/32 A, 400 V, 6H, red, straight 1 circuit breakers, 3-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 32 A 10 kA 1 circuit breakers, 3-pole B63 A 10 kA 2x residual current device 4P / 63 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 35 mm² 1 M50 screw connection 1 line H07 RN-F 5 x 25 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m 1 clamp block 12 x 10mm² 37 Underground distribution system | Underground distribution system with electrical socket combinations Underground distribution system | EK 809 | EK 909 | with removable cover Configuration examples Distributor B780716 front 2x auxiliary windows B78/12TE left 1x ABL17 socket 5/63 A, 400 V, 6H, red, diagonal rear 3x single phase socket, blue, IP54 right 1x ABL17 socket 5/ 16A, 400 V, 6H, red, straight 3x circuit breakers, 1-pole B 16 A 10 kA 1 circuit breakers, 3-pole B 16A 10 kA 1 residual current device 4P / 63 A / 30 mA pulse current sensitive Connection 1 clamp block 2 x 5 x 25 mm² 1 M50 screw connection 1 line H07 RN-F 5 x 16 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m Distributor B780717 front 8x single phase socket, blue, IP54 2x ABL17 socket 5/32 A, 400 V, 6H, red, straight left 2x auxiliary windows B78/12TE 2x circuit breakers, 3-pole B32 A 10 kA rear 4x single phase socket, blue, IP54 1 ABL17 socket 5/16 A, 400 V, 6H, red, straight, 72x65 mm 3x circuit breakers, 3-pole B 16A 10 kA right 2x residual current device 4P / 63 A / 30 mA pulse current sensitive 1 auxiliary window B78/12TE 2x ABL17 socket 5/16 A, 400 V, 6H, red, straight, 72x65 mm 12x circuit breakers, 1-pole B 16 A 10 kA Connection 1 clamp block 2 x 5 x 35 mm² 1 M50 screw connection 1 line H07 RN-F 5 x 25 mm², 2.5 m 1 M16 screw connection 1 line H07VK, 1 x 16 mm² yellow/green 0.5 m 38 Underground distribution system | Underground distribution system for power supply and telecommunication Underground distribution system EK 880 | with horizontally swivelling technical compartment Advantages | manhole and housing High flexibility in the configurations Safe protection of the electronics/electrical fixtures against water ingress using the proven submersion cover principle High mechanical strength High-quality stainless steel design Covers can be used as work platform Safe cable routing, as a cable catch rail is installed in front and after the cable swivelling area No transfer of cover vibrations onto fixtures, as two completely decoupled systems Easy installation, operation and maintenance Advantages | cover Swivel manhole cover: Can be operated by one person without heavy lifting Cover with wider 100° opening angle and self-arrest mechanism Fully removable cover Height-adjustable Safety lock Forced opening in the cover locking mechanism for easy opening in any weather Non-shrink seals for quiet covering Small frame width so that the manhole cover blends inconspicuously into the roadside environment Linear frame contour 39 Underground distribution system | Underground distribution system for power supply and telecommunication Underground distribution system EK 880 | with horizontally swivelling technical compartment Area of application Components for e.g. power supply and telecommunication can be accommodated in the housing, safely protected and hidden in the ground. The innovative cabinet system suitable for underground installations, meets today's requirements regarding: - Flooding protection up to 1 m water height above hood (lower edge) - Heat dissipation - Noise reduction - Appearance - Vandalism EK 880 Inside width: 800 x 1400 mm Outer dimensions: 1240 x 1580 mm Closed height: 930 mm Open height: 2027 mm manhole cover: up to D 400 acc. to DIN EN 124 40 Underground distribution system | Underground distribution system for power supply and telecommunication Underground distribution system EK 880 | with horizontally swivelling technical compartment Housing Single-ply stainless steel housing with door Door variants: - closed front - or with vent grille Strain reliefs and mounting clamps as designed Custom configurations acc. to customer specification Cable entry depending on application Housing size acc. to cable distribution cabinet 82 and/or multifunction housings MFG 8 for telecommunication Mode of operation Cover closed/open With 4-part cast iron cover / D 400 Technical compartment folded open 4-part cast iron cover completely opened Technical compartment – stainless steel housing – folded out and locked in position Free access to installed cable components and cable connections Service platform provided After the folded open housing automatically locks in position, two parts of the cast iron cover are closed and can be used by the service technician as platform in front of the housing. Configuration options Switch disconnector fuse units, max. 6 x NH2, 400 A, 3-pole Telecommunication equipment 19" modular system Mounting plate for individual configuration Further equipment upon request 41 Underground distribution system | Underground distribution system for customised component integration Underground distribution system EK 368 with NH-OO isolator | with IP 68 connection housing Area of application Equipment is protected in waterproof housing Systems for power supply can be integrated. Equipment is tailored to your requirements, safely protected, and accommodated hidden in a manhole Technical data | manhole design Inside width 400 x 650 mm Overall height 515 mm manhole cover: Concreted steel tub or made of cast iron Test class B 125 / D 400 acc. to DIN EN 124 manhole cover: 90° bolt, hexagon head Height compensation kit (up to 50 mm) Cable outlets via set break point in manhole wall Top frame Galvanised steel frame Number of frames/frame height acc. to customer specification Base plate Other manhole sizes and covers upon request Technical data | connection housing Housing with isolator Protection class IP68 acc. to DIN EN 60 529 Housing is mounted on two stainless steel brackets and additionally protected against contamination using a permanently installed protective mat Leak-tight fittings for inlets/outlets NH fuse switch disconnector size 00 / 3-pole switchable Connection using prism clamps Outlet via clamp block on mounting plate Other fixtures upon request 42 Underground distribution system | Underground distribution system for customised component integration Underground distribution system EK 368 with NH-OO isolator | with IP 68 connection housing Material Manhole: PC for all load-bearing components - High temperature resistance - Surface finish with hot mix and mastic asphalt non-critical - Rot proof - High chemical durability - Recyclable Product view 43 Underground distribution system | Underground distribution system for customised component integration Underground distribution system EK 838 | with integrated cable outlet in cast iron cover Area of application The equipment is integrated into the polycarbonate manhole Systems for power supply and telecommunication can be integrated. Equipment is tailored to your requirements, safely protected, and hidden in the ground Technical data | manhole design Inside width 400 x 650 mm manhole cover: Height 95 mm Steel frame, galvanised and connected with top frame (no height adjustment possible) Outer standard height approx. 680 mm (compact manhole K1) Alternative: Variable number of frames/frame height acc. to customer request with top frame (see drawing on next page) Base plate Technical data | cover Cover made of cast iron Load 125 kN Advantages Integrated cable outlet in cast iron cover - Fixed stops at two opening angles - Effective cable protection when driving over manhole Cover lockable with open or closed cable outlet No above-ground location is needed, as with cable distribution cabinets Cover can be opened by one person Manhole material: PC for all load-bearing components - High temperature resistance - Surface finish with hot mix and mastic asphalt non-critical - Rot proof - High chemical durability - Recyclable 44 Underground distribution system | Underground distribution system for customised component integration Underground distribution system EK 838 | with integrated cable outlet in cast iron cover Installation Equipment acc. to customer request Dimensions Manhole in standard height (compact ma K1) Example: Manhole with variable number of frames/frame height 45 Underground distribution system | Underground distribution system for customised component integration Underground distribution system EK 838 | with integrated cable outlet in cast iron cover Mode of operation The equipment is integrated into the polycarbonate manhole Systems for power supply, telecommunication, water and gas can be integrated. Equipment is tailored to your requirements, safely protected, and accommodated hidden in the ground Unlocking the cover Opening and latching the main cover Inserting supply lines Closing the main cover, folding cover remains open Integrated cable outlet in cast iron cover Folding cover for cable outlet - Large opening angle Folding cover for cable outlet - Small opening angle 46 Underground distribution system | Underground distribution system for customised component integration | Motorway roadside emergency telephone column manhole EK 383 Roadside emergency telephone manhole with emergency telephone calibration options and end cap accommodation Advantages No concrete foundation required Easy cable entry into manhole using set break point elements Comfortable emergency telephone adjustment, adjusting range +/- 3° Increased workspace for technician – 70 x 65 cm Reserve service cable is attached at the side in manhole, no excavation necessary to release reserve cable End cap mounting with tilting mechanism for ease of assembly Rain-proof cover with an overlapping hot-dip galvanised steel cover Safeguard against unauthorised opening of the cover Emergency telephone base and manhole form an entity easy cabling between end cap and column Lower manhole weight as designed in polycarbonate, simplified handling during assembly Integrated lifting rod for energy saving opening of the cover with hinges and locking device Column base open for emergency telephone connection cable including high-strength cable gland Column has a greater distance from the safety barrier due to its asymmetrical arrangement Adjustment device for column adjusting range +/- 3° Surrounding gutter between the fixed and swivelling cover components, to prevent surface water penetration 47 Underground distribution system | Underground distribution system for customised component integration | Motorway roadside emergency telephone column manhole EK 383 Technical data Outer dimensions: 869 x 1376 mm Inside width: 650 x 1165 mm Material: Polycarbonate Outer standard height approx. 778 mm Number of frames/frame height acc. to customer request Steel frame, galvanised and connected with top frame (no height adjustment possible) Cover: overlapping hot-dip galvanised steel cover, 2-part Base plate Closed cover In locked condition Open cover, telescopic rod as lifting aid In unlocked condition 48 Underground distribution system | References References Excerpt from our customer list Utility companies Telecommunications companies Public transport, railways Local authorities, municipalities System integrators Builders' merchants Installation companies Underground distribution systems made by Langmatz are used nationally and internationally. Please contact use for local references in your area. 49 Contact | Contacts Telephone | Phone Internet Langmatz GmbH Am Gschwend 10 D-82467 Garmisch-Partenkirchen | Germany Telephone +49 88 21 920-0 Fax +49 88 21 920-159 Email info@langmatz.de Internet www.langmatz.de Subject to technical modifications | As of 11-2015 We are looking forward to a visit, a call or an email from you.