Home Inspection Report prepared exclusively for Homer Buyer Property Address: 103 New House Lane Virginia Beach VA Ken Melton's Homebuyer Inspections Ken Melton 757-717-6098 Table of Contents Cover Page.................................................................................................... 0 Table of Contents .......................................................................................... 0 Intro Page ...................................................................................................... 0 1 APPLIANCES ............................................................................................. 4 2 PLUMBING SYSTEM ................................................................................. 5 3 INTERIORS ................................................................................................ 7 4 FIREPLACES AND SOLID FUEL BURNING DEVICES ............................ 8 5 EXTERIOR ................................................................................................. 9 6 ROOFING,FLASHINGS, CHIMNEYS, ROOF STRUCTURE AND ATTIC11 7 HEAT PUMP (heats and cools) ................................................................ 13 8 ELECTRICAL SYSTEMS ......................................................................... 14 9 INSULATION & VENTILATION ................................................................ 16 10 STRUCTURAL COMPONENTS, CRAWL SPACES & BASEMENTS ... 17 11 GARAGE ................................................................................................ 18 Summary ....................................................................................................... 0 Invoice ........................................................................................................... 0 Date: 6/24/2010 Time: 02:45 PM Report ID: 06242010 Buyer Property: 103 New House Lane Virginia Beach VA Customer: Homer Buyer Real Estate Professional: John Seller Realty Max THIS REPORT IS THE PROPERTY OF KEN MELTON'S HOMEBUYER INSPECTIONS AND THE CLIENT(S) AND IS VALID FOR THE DATE OF THE INSPECTION ONLY. COPIES OF THIS INSPECTION REPORT ARE DISTRIBUTED TO OTHER PARTIES AS A COURTESY AND SHALL NOT BE USED FOR ANY FUTURE TRANSACTIONS ON THIS PROPERTY. Comment Key or Definitions The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. • Inspected = The item, component or unit was observed and / or operated, appeared to be performing the function for which it was designed, and no visual deficiencies were noted with exception to normal wear and tear. • Not Inspected = I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. • Partial Evaluation Only = I could not perform a complete inspection of this item, component or unit and made no representations of whether or not it was functioning as intended. I will state a reason for not performing a complete inspection and any appropriate recommendations. • Not Present = This item, component or unit is not in this home or building. • Evaluate / Service Repair = The item, component or unit was inspected and is not functioning as intended and needs further inspection / repair / replacement by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. • Evaluate / Maintenance Repair = is not functioning as intended and needs repair. These repairs can often be accomplished by a good handyman or skilled homeowner. • For Your Information = The home inspector reserves this comment to provide information to you about items, components or units in the home. He also may make suggestions that improve the appearance, functionality, and safety of the home. Age Of Home: Client Is Present: Weather: Reported to be built in 1994 Yes Clear, Hot and Humid Temperature (degrees farenheit): 90-100 1. APPLIANCES The Home Inspector as a professional courtesy will at the request of the client observe and operate the basic functions of the built in appliances. The Home Inspector as a professional courtesy will at the request of the client observe and operate the basic functions of the built in appliances. GENERAL INFORMATION RANGE: KITCHEN VENTILATION: DISHWASHER: ELECTRIC EXHAUST HOOD BUILT-IN RECIRCULATOR GARBAGE DISPOSAL: CONTINUOUS FEED INSPECTION ITEMS 1.0 RANGES/OVENS/COOKTOPS Inspected 1.1 KITCHEN VENTILATION Inspected 1.2 DISHWASHER See Comments Below Dishwasher did not operate when tested. Have corrected by a qualified person. 1.3 FOOD WASTE DISPOSER Inspected 2. PLUMBING SYSTEM The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. GENERAL INFORMATION WATER SOURCE: MAIN WATER SHUT-OFF LOCATION: PLUMBING SUPPLY: PUBLIC WATER METER POLYBUTYLENE EXPOSED PLUMBING DISTRIBUTION: PLUMBING VENT & WASTE: WATER HEATER: POLYBUTYLENE PVC ELECTRIC 50 GALLON 15 YEARS OLD INSPECTION ITEMS 2.0 WATER SUPPLY AND DISTRIBUTION SYSTEMS See Comments Below 2.1 DRAIN, WASTE AND VENT SYSTEMS Inspected 2.2 FIXTURES ( includes bath, laundry,kitchen, hose bibs, etc.) See Comments Below (1) Faucet for tub in hall bath diverter leaks by and has low water pressure from shower head. Minor repairs are needed. Recommend repair as necessary by a qualified person 2.2 Picture 1 (2) Shower stall is cracked at Master Bath. Repairs are need to prevent damage / further damage to the floor. Recommend repair as necessary by a qualified person. 2.2 Picture 2 2.3 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Inspected 3. INTERIORS GENERAL INFORMATION LIMITATIONS TO INSPECTION OF THE INTERIOR: NONE - HOUSE IS VACANT INSPECTION ITEMS 3.0 CEILINGS & WALLS Inspected 3.1 FLOORS Inspected 3.2 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS See Comments Below Drawer is missing (left of stove). Recommend repair or replace as necessary. 3.2 Picture 1 3.3 DOORS (REPRESENTATIVE NUMBER) See Comments Below Doors are not undercut and drag carpet throughout. Additionally, this affects air returning back to the HVAC central return. Several doors stick. 3.3 Picture 1 3.4 WINDOWS (REPRESENTATIVE NUMBER) Inspected 4. FIREPLACES AND SOLID FUEL BURNING DEVICES The home inspector shall observe chimneys, flues, and vents, where readily visible and solid fuel heating devices. The home inspector shall describe: Energy source; and equipment type. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections. GENERAL INFORMATION FIREPLACES / SOLID FUEL BURNING DEVICE TYPE: CHIMNEY TYPE: PREFABRICATED METAL CHIMNEY LINER INSPECTION ITEMS 4.0 FIREPLACES / WOODSTOVE'S / GAS LOGS Inspected 4.1 CHIMNEYS, FLUES AND VENTS Inspected 5. EXTERIOR The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. GENERAL INFORMATION SIDING MATERIAL: ATTACHED EXTERIOR STRUCTURES: PATIOS & WALKWAYS: VINYL COVERED PORCH CONCRETE DRIVEWAYS: CONCRETE INSPECTION ITEMS 5.0 WALL CLADDING (siding) See Comments Below Siding has minor wear and tear which is generally cosmetic in nature. No action required. 5.1 EAVES, SOFFITS, FASCIAS AND TRIM See Comments Below Aluminum trim at fascia at right side (facing front) of home is loose. Deterioration may occur if not corrected. Have corrected by a qualified person. 5.1 Picture 1 5.2 EXTERIOR DOORS (excluding storm doors) Inspected 5.3 WINDOWS Inspected 5.4 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS See Comments Below Decking on Deck at rear of home warped, and needs repair or replace. A fall or injury can occur if not corrected. Recommend repair or replace by a qualified person. 5.4 Picture 1 5.5 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) See Comments Below Tree limbs that are in contact with roof or hanging near roof should be trimmed. 5.5 Picture 1 6. ROOFING,FLASHINGS, CHIMNEYS, ROOF STRUCTURE AND ATTIC The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors. GENERAL INFORMATION ROOF INSPECTION BY:: ROOF COVERING TYPE(S): CHIMNEY (exterior): WALKED ROOF 3-TAB COMPOSITION SHINGLE VINYL SIDING NORMAL WEAR FOR AGE METAL CAP Extra Info : Roughly 5 years left in roof ROOF STRUCTURE: ROOF DRAINAGE: ENGINERED WOOD TRUSSES GUTTERS AND DOWNSPOUTS INSPECTION ITEMS 6.0 ROOF COVERINGS See Comments Below Shingle(s) damaged at front of home. Repairs are required to prevent damage/further damage to the roof structure. Recommend repair or replace by a qualified person 6.0 Picture 1 6.1 FLASHINGS Inspected 6.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS See Comments Below 6.0 Picture 2 (1) Plumbing vent pipe(s) (through roof) has a flashing boot that is deteriorated and requires replacement on rear of home. This area can leak if not corrected. Recommend repair or replace by a qualified person. 6.2 Picture 1 (2) Metal cover on top of on chimney chase is rusted. Deterioration may occur if not corrected. Recommend prep prime and paint. 6.2 Picture 2 6.3 ROOFING DRAINAGE SYSTEMS Inspected 6.4 ROOF STRUCTURE & ATTIC Inspected 6.5 ATTIC ACCESS Inspected 7. HEAT PUMP (heats and cools) GENERAL INFORMATION HEAT PUMP (HEATING AND COOLING ) / ZONE: OUTDOOR UNIT: INDOOR UNIT: HEAT PUMP NEW 5 YEARS OLD POWER SOURCE - ELECTRIC 2 TON 2 TON BACKUP HEAT SOURCE - ELECTRIC AIR TO AIR HEAT PUMP DISTRIBUTION: FILTER LOCATIONS / SIZES: DUCTWORK AND REGISTERS 14" x 20" INSULATED INSPECTION ITEMS 7.0 HEAT PUMP EQUIPMENT See Comments Below Ambient air test was performed by using thermometers to test the Heat pump in cool mode to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates unit is cooling as intended. The supply air temperature on your system read 72 degrees, and the return air temperature was 82 degrees. This indicates that the unit is not cooling properly and a licensed Heat/Air contractor should inspect for cause or problem. Note: The freon line is not getting cold and sweaty as it should be. 7.1 NORMAL OPERATING CONTROLS See Comments Below Thermostat is damaged. Recommend repair or replace by a licensed HVAC Contractor. 7.1 Picture 1 7.2 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Inspected 7.3 PRESENCE OF INSTALLED HEATING / COOLING SOURCE IN EACH ROOM Inspected 8. ELECTRICAL SYSTEMS The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment. GENERAL INFORMATION ELECTRICAL SERVICE CONDUCTORS: MAIN ELECTRICAL PANEL: BRANCH WIRE 15 and 20 AMP: BELOW GROUND 150 AMP COPPER ALUMINUM CIRCUIT BREAKERS 220 VOLTS GARAGE WIRING METHODS: OUTLET TYPES: GFCI LOCATIONS: NM (non-metallic sheathing) Grounded 3 PRONG BATHS KITCHEN GARAGE OUTSIDE SMOKE DETECTOR LOCATIONS: HALL INSPECTION ITEMS 8.0 SERVICE ENTRANCE CONDUCTORS Inspected 8.1 SERVICE AND GROUNDING EQUIPMENT, MAIN AND BRANCH CIRCUIT OVERCURRENT DEVICES, MAIN AND DISTRIBUTION PANELS Inspected 8.2 BRANCH CIRCUIT CONDUCTORS (wiring) Inspected 8.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) See Comments Below (1) Outlet and switch covers missing in bedroom and attic. Damaged outlet in the hall. Shock hazard. Have corrected by a qualified person. 8.3 Picture 1 (2) Wall switch is worn out (intermittent operation) at hall bath. Replacement is likely. Have corrected by a qualified person. 8.4 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Inspected 8.5 PRESENCE OF SMOKE DETECTORS See Comments Below Smoke detectors are recommended on each level and all bedrooms.Recommend new smoke detectors. 9. INSULATION & VENTILATION GENERAL INFORMATION ATTIC VENTILATION: ATTIC INSULATION: BATHROOM VENTILATION: PASSIVE LOOSE FILL FANS THERMOSTATICALLY CONTROLLED FAN INSUL-SAFE GOOD LAUNDRY VENTILATION: VENTS OUTSIDE INSPECTION ITEMS 9.0 INSULATION IN ATTIC Inspected 9.1 VENTILATION OF ATTIC Inspected 9.2 VENTING SYSTEMS See Comments Below The dryer vent is damaged. Replacement is necessary. 9.2 Picture 1 10. STRUCTURAL COMPONENTS, CRAWL SPACES & BASEMENTS The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons. GENERAL INFORMATION FOUNDATION: FLOOR STRUCTURE: WALL STRUCTURE: CONCRETE SLAB CONCRETE SLAB WOOD FRAMING 2 X 4 WOOD INSPECTION ITEMS 10.0 STRUCTURAL COMPONENTS Inspected 11. GARAGE GENERAL INFORMATION GARAGE DOOR OPENER: GARAGE CEILING: GARAGE WALL: AUTOMATIC SHEETROCK SHEETROCK AUTO REVERSE - YES REVERSES BY SENSORS GARAGE FLOOR: ENTRANCE DOORS: CONCRETE METAL INSPECTION ITEMS 11.0 GARAGE DOOR OPERATORS Inspected 11.1 GARAGE CEILINGS & WALLS Inspected 11.2 GARAGE FLOOR Inspected 11.3 OCCUPANT DOOR FROM GARAGE TO INSIDE HOME Inspected Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Ken Melton's Homebuyer Inspections Summary Ken Melton's Homebuyer Inspections 757-717-6098 Customer Homer Buyer Address 103 New House Lane Virginia Beach VA THIS SUMMARY REPORT IS THE PROPERTY OF KEN MELTON'S HOMEBUYER INSPECTIONS AND THE CLIENT(S) AND IS VALID FOR THE DATE OF THE INSPECTION ONLY. COPIES OF THIS INSPECTION SUMMARY REPORT ARE DISTRIBUTED TO OTHER PARTIES AS A COURTESY AND SHALL NOT BE USED FOR ANY FUTURE TRANSACTIONS ON THIS PROPERTY. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 1. APPLIANCES EVALUATE / MAINTENANCE REPAIR 1.2 DISHWASHER See Comments Below Dishwasher did not operate when tested. Have corrected by a qualified person. 2. PLUMBING SYSTEM EVALUATE / MAINTENANCE REPAIR 2.2 FIXTURES ( includes bath, laundry,kitchen, hose bibs, etc.) See Comments Below (1) Faucet for tub in hall bath diverter leaks by and has low water pressure from shower head. Minor repairs are needed. Recommend repair as necessary by a qualified person 2.2 Picture 1 (2) Shower stall is cracked at Master Bath. Repairs are need to prevent damage / further damage to the floor. Recommend repair as necessary by a qualified person. 2.2 Picture 2 3. INTERIORS EVALUATE / MAINTENANCE REPAIR 3.2 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS See Comments Below Drawer is missing (left of stove). Recommend repair or replace as necessary. 3.2 Picture 1 3.3 DOORS (REPRESENTATIVE NUMBER) See Comments Below Doors are not undercut and drag carpet throughout. Additionally, this affects air returning back to the HVAC central return. Several doors stick. 3.3 Picture 1 5. EXTERIOR EVALUATE / MAINTENANCE REPAIR 5.1 EAVES, SOFFITS, FASCIAS AND TRIM See Comments Below Aluminum trim at fascia at right side (facing front) of home is loose. Deterioration may occur if not corrected. Have corrected by a qualified person. 5.1 Picture 1 5.4 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS See Comments Below Decking on Deck at rear of home warped, and needs repair or replace. A fall or injury can occur if not corrected. Recommend repair or replace by a qualified person. 5.4 Picture 1 FOR YOUR INFORMATION 5.0 WALL CLADDING (siding) See Comments Below Siding has minor wear and tear which is generally cosmetic in nature. No action required. 5.5 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) See Comments Below Tree limbs that are in contact with roof or hanging near roof should be trimmed. 5.5 Picture 1 6. ROOFING,FLASHINGS, CHIMNEYS, ROOF STRUCTURE AND ATTIC EVALUATE / MAINTENANCE REPAIR 6.0 ROOF COVERINGS See Comments Below Shingle(s) damaged at front of home. Repairs are required to prevent damage/further damage to the roof structure. Recommend repair or replace by a qualified person 6.0 Picture 1 6.0 Picture 2 6.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS See Comments Below (1) Plumbing vent pipe(s) (through roof) has a flashing boot that is deteriorated and requires replacement on rear of home. This area can leak if not corrected. Recommend repair or replace by a qualified person. 6.2 Picture 1 (2) Metal cover on top of on chimney chase is rusted. Deterioration may occur if not corrected. Recommend prep prime and paint. 6.2 Picture 2 7. HEAT PUMP (heats and cools) EVALUATE / SERVICE REPAIR 7.0 HEAT PUMP EQUIPMENT See Comments Below Ambient air test was performed by using thermometers to test the Heat pump in cool mode to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates unit is cooling as intended. The supply air temperature on your system read 72 degrees, and the return air temperature was 82 degrees. This indicates that the unit is not cooling properly and a licensed Heat/Air contractor should inspect for cause or problem. Note: The freon line is not getting cold and sweaty as it should be. EVALUATE / MAINTENANCE REPAIR 7.1 NORMAL OPERATING CONTROLS See Comments Below Thermostat is damaged. Recommend repair or replace by a licensed HVAC Contractor. 7.1 Picture 1 8. ELECTRICAL SYSTEMS EVALUATE / MAINTENANCE REPAIR 8.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) See Comments Below (1) Outlet and switch covers missing in bedroom and attic. Damaged outlet in the hall. Shock hazard. Have corrected by a qualified person. 8.3 Picture 1 (2) Wall switch is worn out (intermittent operation) at hall bath. Replacement is likely. Have corrected by a qualified person. FOR YOUR INFORMATION 8.5 PRESENCE OF SMOKE DETECTORS See Comments Below Smoke detectors are recommended on each level and all bedrooms.Recommend new smoke detectors. 9. INSULATION & VENTILATION EVALUATE / MAINTENANCE REPAIR 9.2 VENTING SYSTEMS See Comments Below The dryer vent is damaged. Replacement is necessary. 9.2 Picture 1 Prepared Using HomeGauge http://www.HomeGauge.com : Licensed To Ken Melton's Homebuyer Inspections INVOICE Ken Melton's Homebuyer Inspections 757-717-6098 Inspected By: Ken Melton Customer Info: Homer Buyer Inspection Date: 6/24/2010 Report ID: 06242010 Buyer Inspection Property: 103 New House Lane Virginia Beach VA Customer's Real Estate Professional: John Seller Realty Max Inspection Fee: Service Total Square Feet 1000 - 1499 Price Amount Sub-Total 265.00 1 265.00 Tax $0.00 Total Price $265.00 Payment Method: At Inspection Payment Status: Paid In Full Note: