Cyclone IV Device Handbook, Volume 1 101 Innovation Drive San Jose, CA 95134 www.altera.com CYIV-5V1-1.0 Copyright © 2009 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. RSDS and PPDS are registered trademarks of National Semiconductor. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Contents Chapter Revision Dates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Additional Information About this Handbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-xi How to Contact Altera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-xi Typographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-xi Section 1. Device Core Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Chapter 1. Cyclone IV FPGA Device Family Overview Cyclone IV Device Family Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Package Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cyclone IV Device Family Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FPGA Core Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clock Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Memory Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-Speed Transceivers (Cyclone IV GX Devices Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hard IP for PCI Express (Cyclone IV GX Devices Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference and Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-3 1-4 1-6 1-6 1-6 1-7 1-7 1-7 1-8 1-9 1-9 1-9 Chapter 2. Logic Elements and Logic Array Blocks in Cyclone IV Devices Logic Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LE Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LE Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arithmetic Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Logic Array Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LAB Interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LAB Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-3 2-3 2-4 2-4 2-4 2-5 2-6 2-7 Chapter 3. Memory Blocks in Cyclone IV Devices Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parity Bit Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Byte Enable Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Packed Mode Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Address Clock Enable Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mixed-Width Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Asynchronous Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Memory Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . © November 2009 Altera Corporation 3-1 3-3 3-3 3-3 3-4 3-4 3-6 3-6 3-7 Cyclone IV Device Handbook, Volume 1 iv Contents Single-Port Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Simple Dual-Port Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 True Dual-Port Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 Shift Register Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 ROM Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 FIFO Buffer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Clocking Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 Independent Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 Input or Output Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14 Read or Write Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 Single-Clock Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 Read-During-Write Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15 Same-Port Read-During-Write Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16 Mixed-Port Read-During-Write Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 Conflict Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 Power-Up Conditions and Memory Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18 Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18 Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18 Chapter 4. Embedded Multipliers in Cyclone IV Devices Embedded Multiplier Block Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Multiplier Stage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operational Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-Bit Multipliers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-Bit Multipliers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-2 4-3 4-3 4-4 4-4 4-5 4-5 4-7 Chapter 5. Clock Networks and PLLs in Cyclone IV Devices Clock Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 GCLK Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Clock Control Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 GCLK Network Clock Source Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-9 GCLK Network Power Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11 clkena Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12 PLLs in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13 Cyclone IV PLL Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 External Clock Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15 Clock Feedback Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17 Source-Synchronous Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17 No Compensation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18 Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19 Zero Delay Buffer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20 Deterministic Latency Compensation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20 Hardware Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21 Clock Multiplication and Division . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21 Post-Scale Counter Cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22 Programmable Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22 PLL Control Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23 Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Contents v Clock Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automatic Clock Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Clock Switchover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programmable Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Phase Shift Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL Cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL Reconfiguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL Reconfiguration Hardware Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Post-Scale Counters (C0 to C4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scan Chain Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Charge Pump and Loop Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bypassing a PLL Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dynamic Phase Shifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spread-Spectrum Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23 5-23 5-25 5-25 5-26 5-27 5-27 5-29 5-29 5-29 5-31 5-32 5-33 5-34 5-34 5-36 5-36 5-37 Section 2. I/O Interfaces Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Chapter 6. I/O Features in Cyclone IV Devices Cyclone IV I/O Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 I/O Element Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Programmable Current Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Slew Rate Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Open-Drain Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Bus Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 Programmable Pull-Up Resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 Programmable Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 PCI-Clamp Diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 OCT Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6 On-Chip Series Termination with Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8 On-Chip Series Termination Without Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10 I/O Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11 Termination Scheme for I/O Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13 Voltage-Referenced I/O Standard Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13 Differential I/O Standard Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-14 I/O Banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 High-Speed Differential Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19 External Memory Interfacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Pad Placement and DC Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 Pad Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 DC Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 High-Speed I/O Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21 High-Speed I/O Standards Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22 High Speed Serial Interface (HSSI) Input Reference Clock Support . . . . . . . . . . . . . . . . . . . . . . . . . 6-22 LVDS I/O Standard Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23 Designing with LVDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-24 BLVDS I/O Standard Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-25 Designing with BLVDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-25 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 vi Contents RSDS, Mini-LVDS, and PPDS I/O Standard Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . Designing with RSDS, Mini-LVDS, and PPDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LVPECL I/O Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential SSTL I/O Standard Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential HSTL I/O Standard Support in Cyclone IV Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . True Output Buffer Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programmable Pre-Emphasis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . High-Speed I/O Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Design Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Differential Pad Placement Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Board Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26 6-26 6-28 6-29 6-29 6-30 6-30 6-31 6-32 6-32 6-32 6-33 6-34 Chapter 7. External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Data and Data Clock/Strobe Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 Optional Parity, DM, and Error Correction Coding Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7 Address and Control/Command Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7 Memory Clock Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7 Cyclone IV Devices Memory Interfaces Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 DDR Input Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 DDR Output Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 OCT with Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 PLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 Section 3. System Integration Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Chapter 8. Configuration and Remote System Upgrades in Cyclone IV Devices Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 Configuration Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Configuration Data Decompression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2 Configuration Requirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Power-On Reset (POR) Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Configuration File Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 Configuration and JTAG Pin I/O Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4 Configuration Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-5 Configuration Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 User Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6 Configuration Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7 AS Configuration (Serial Configuration Devices) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8 Single-Device AS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8 Multi-Device AS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10 Configuring Multiple Cyclone IV Devices with the Same Design . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 Guidelines for Connecting Serial Configuration Device to Cyclone IV Devices on a AS Interface . 8-15 Programming Serial Configuration Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-15 Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Contents vii PS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS Configuration Using an External Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS Configuration Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PS Configuration Using a Download Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FPP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FPP Configuration Using an External Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FPP Configuration Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JTAG Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Cyclone IV Devices with Jam STAPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Cyclone IV Devices with the JRunner Software Driver . . . . . . . . . . . . . . . . . . . . . . Combining JTAG and AS Configuration Schemes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming Serial Configuration Devices In-System with the JTAG Interface . . . . . . . . . . . . JTAG Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Configuration Pins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote System Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling Remote Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Image Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote System Upgrade Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote Update Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dedicated Remote System Upgrade Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote System Upgrade Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote System Upgrade State Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Watchdog Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quartus II Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-18 8-19 8-22 8-23 8-26 8-26 8-30 8-31 8-38 8-38 8-39 8-41 8-43 8-46 8-51 8-51 8-52 8-52 8-52 8-53 8-54 8-55 8-59 8-59 8-60 8-60 Chapter 9. SEU Mitigation in Cyclone IV Devices Configuration Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 User Mode Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 Automated SEU Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 CRC_ERROR Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 Error Detection Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Error Detection Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 Error Detection Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 Software Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7 Accessing Error Detection Block Through User Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-8 Recovering from CRC Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10 Chapter 10. JTAG Boundary-Scan Testing for Cyclone IV Devices IEEE Std. 1149.6 Boundary-Scan Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BST Operation Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EXTEST_PULSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EXTEST_TRAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I/O Voltage Support in a JTAG Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Boundary-Scan Description Language Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2 10-3 10-4 10-4 10-5 10-6 10-6 Chapter 11. Power Requirements for Cyclone IV Devices External Power Supply Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1 Hot-Socketing Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-2 Devices Driven Before Power-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 viii Contents I/O Pins Remain Tri-stated During Power-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hot-socketing Feature Implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power-On Reset Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cyclone IV Device Handbook, Volume 1 11-3 11-3 11-3 11-4 © November 2009 Altera Corporation Chapter Revision Dates The chapters in this book, Cyclone IV Device Handbook, Volume 1, were revised on the following dates. Where chapters or groups of chapters are available separately, part numbers are listed. Chapter 1 Cyclone IV FPGA Device Family Overview Revised: November 2009 Part Number: CYIV-51001-1.0 Chapter 2 Logic Elements and Logic Array Blocks in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51002-1.0 Chapter 3 Memory Blocks in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51003-1.0 Chapter 4 Embedded Multipliers in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51004-1.0 Chapter 5 Clock Networks and PLLs in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51005-1.0 Chapter 6 I/O Features in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51006-1.0 Chapter 7 External Memory Interfaces in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51007-1.0 Chapter 8 Configuration and Remote System Upgrades in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51008-1.0 Chapter 9 SEU Mitigation in Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51009-1.0 Chapter 10 JTAG Boundary-Scan Testing for Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51010-1.0 Chapter 11 Power Requirements for Cyclone IV Devices Revised: November 2009 Part Number: CYIV-51011-1.0 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 x Cyclone IV Device Handbook, Volume 1 Chapter Revision Dates © November 2009 Altera Corporation Additional Information About this Handbook This handbook provides comprehensive information about the Altera® Cyclone® IV family of devices. How to Contact Altera For the most up-to-date information about Altera products, see the following table. Contact (Note 1) Contact Method Address Technical support Website www.altera.com/support Technical training Website www.altera.com/training Email custrain@altera.com Non-technical support (General) Email nacomp@altera.com (Software Licensing) Email authorization@altera.com Note: (1) You can also contact your local Altera sales office or sales representative. Typographic Conventions The following table shows the typographic conventions that this document uses. Visual Cue Meaning Bold Type with Initial Capital Letters Indicates command names, dialog box titles, dialog box options, and other GUI labels. For example, Save As dialog box. For GUI elements, capitalization matches the GUI. bold type Indicates directory names, project names, disk drive names, file names, file name extensions, dialog box options, software utility names, and other GUI labels. For example, \qdesigns directory, d: drive, and chiptrip.gdf. Italic Type with Initial Capital Letters Indicates document titles. For example, AN 519: Stratix IV Design Guidelines. Italic type Indicates variables. For example, n + 1. Variable names are enclosed in angle brackets (< >). For example, <file name> and <project name>.pof. Initial Capital Letters Indicates keyboard keys and menu names. For example, Delete key and the Options menu. “Subheading Title” Quotation marks indicate references to sections within a document and titles of Quartus II Help topics. For example, “Typographic Conventions.” © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 Info–xii Additional Information Visual Cue Courier type Meaning Indicates signal, port, register, bit, block, and primitive names. For example, data1, tdi, and input. Active-low signals are denoted by suffix n. For example, resetn. Indicates command line commands and anything that must be typed exactly as it appears. For example, c:\qdesigns\tutorial\chiptrip.gdf. Also indicates sections of an actual file, such as a Report File, references to parts of files (for example, the AHDL keyword SUBDESIGN), and logic function names (for example, TRI). 1., 2., 3., and a., b., c., and so on. Numbered steps indicate a list of items when the sequence of the items is important, such as the steps listed in a procedure. ■ ■ Bullets indicate a list of items when the sequence of the items is not important. 1 The hand points to information that requires special attention. c A caution calls attention to a condition or possible situation that can damage or destroy the product or your work. w A warning calls attention to a condition or possible situation that can cause you injury. r The angled arrow instructs you to press Enter. f The feet direct you to more information about a particular topic. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Section 1. Device Core This section provides a complete overview of all features relating to the Cyclone® IV device family, which is the most architecturally advanced, high-performance, low-power FPGA in the market place. This section includes the following chapters: ■ Chapter 1, Cyclone IV FPGA Device Family Overview ■ Chapter 2, Logic Elements and Logic Array Blocks in Cyclone IV Devices ■ Chapter 3, Memory Blocks in Cyclone IV Devices ■ Chapter 4, Embedded Multipliers in Cyclone IV Devices ■ Chapter 5, Clock Networks and PLLs in Cyclone IV Devices Revision History Refer to each chapter for its own specific revision history. For information about when each chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 1. Cyclone IV FPGA Device Family Overview CYIV-51001-1.0 Altera’s new Cyclone® IV FPGA device family extends the Cyclone FPGA series leadership in providing the market’s lowest-cost, lowest-power FPGAs, now with a transceiver variant. Cyclone IV devices are targeted to high-volume, cost-sensitive applications, enabling system designers to meet increasing bandwidth requirements while lowering costs. Built on an optimized low-power process, the Cyclone IV device family offers the following two variants: ■ Cyclone IV E—lowest power, high functionality with the lowest cost ■ Cyclone IV GX—lowest power and lowest cost FPGAs with 3.125 Gbps transceivers Providing power and cost savings without sacrificing performance, along with a low-cost integrated transceiver option, Cyclone IV devices are ideal for low-cost, small-form-factor applications in the wireless, wireline, broadcast, industrial, consumer, and communications industries. Cyclone IV Device Family Features The Cyclone IV device family offers the following features: ■ © November 2009 Low cost, low power FPGA fabric: ■ 6K to 155K logic elements ■ Up to 6 Mb of embedded memory ■ Up to 360 18 × 18 multipliers for DSP processing intensive applications ■ Protocol bridging applications for under 1.5 W total power Altera Corporation Cyclone IV Device Handbook, Volume 1 1–2 Chapter 1: Cyclone IV FPGA Device Family Overview Cyclone IV Device Family Features ■ ■ ■ Cyclone IV GX devices offer up to eight high-speed transceivers that provide: ■ Data rates up to 3.125 Gbps ■ 8B10B encoder/decoder ■ 8-bit or 10-bit PMA to PCS interface ■ Byte serializer/deserializer ■ Word aligner ■ Rate matching FIFO ■ TX bit slipper for CPRI ■ Electrical idle ■ Dynamic channel reconfiguration allowing you to change data rates and protocols on-the-fly ■ Static equalization and pre-emphasis for superior signal integrity ■ 150 mW per channel power consumption ■ Flexible clocking structure to support multiple protocols in a single transceiver block Cyclone IV GX devices offer dedicated Hard IP for PCI Express Gen 1: ■ ×1, ×2, and ×4 lane configurations ■ End point and root port configurations ■ Up to 256-byte payload ■ One virtual channel ■ 2 KB retry buffer ■ 4 KB RX buffer Cyclone IV GX devices offer a wide range of protocol support: ■ PCI Express Gen 1 ×1, ×2, and ×4 (2.5 Gbps) ■ Gigabit Ethernet (1.25 Gbps) ■ Common Public Radio Interface (CPRI) (up to 3.072 Gbps) ■ XAUI (3.125 Gbps) ■ Triple rate Serial Digital Interface (SDI) (up to 2.97 Gbps) ■ Serial RapidIO (3.125 Gbps) ■ Basic mode (up to 3.125 Gbps) ■ V-by-One (up to 3.0 Gbps) ■ DisplayPort (2.7 Gbps) ■ SATA (up to 3.0 Gbps) Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 1: Cyclone IV FPGA Device Family Overview Device Resources ■ 1–3 Up to 535 user I/Os ■ LVDS interfaces up to 840 Mbps TX, 875 Mbps RX ■ Support for DDR2 SDRAM interfaces up to 200 MHz ■ Support for QDRII SRAM and DDR SDRAM up to 167 MHz ■ Up to eight PLLs per device ■ Offered in commercial and industrial temperature grades Device Resources Table 1–1 shows Cyclone IV E device resources. Table 1–1. Cyclone IV E Device Resources Resources EP4CE6 EP4CE10 Logic elements (LEs) EP4CE15 EP4CE30 EP4CE40 EP4CE55 EP4CE75 EP4CE115 6,272 10,320 15,408 28,848 39,600 55,856 75,408 114,480 Embedded memory (Kbits) 270 414 504 594 1,134 2,340 2,745 3,888 Embedded 18 × 18 multipliers 15 23 56 66 116 154 200 266 General-purpose PLLs 2 2 4 4 4 4 4 4 182 182 346 535 535 377 429 531 Maximum user I/O Table 1–2 shows Cyclone IV GX device resources. Table 1–2. Cyclone IV GX Device Resources Resources Logic elements (LEs) EP4CGX15 EP4CGX22 EP4CGX30 EP4CGX50 EP4CGX75 EP4CGX110 EP4CGX150 14,400 21,280 29,440 49,888 73,920 109,424 149,760 540 756 1,080 2,502 4,158 5,490 6,480 Embedded 18 × 18 multipliers 0 40 80 140 198 280 360 General-purpose PLLs (GPLLs) 1 2 2 4 (2) 4 (2) 4 (2) 4 (2) Embedded memory (Kbits) 2 (1) 2 (1) 2 (1) 4 (1) 4 (1) 4 (1) 4 (1) Global clock networks Multi-purpose PLLs (MPLLs) 20 20 20 30 30 30 30 High-speed transceivers (5) 2 4 4 8 8 8 8 2.5 2.5 2.5 3.125 3.125 3.125 3.125 1 1 1 1 1 1 1 9 (3) 9 (3) 9 (3) 11 (4) 11 (4) 11 (4) 11 (4) 72 150 150 310 310 475 475 Transceiver maximum data rate (Gbps) PCI Express Hard IP blocks User I/O banks Maximum user I/O Notes to Table 1–2: (1) The MPLLs can be used for general purpose clocking when not used to clock the transceivers. For more information, refer to the Clock Networks and PLLs in Cyclone IV Devices chapter. (2) Two of the GPLLs are able to support the transceiver clocking. For more information, refer to the Clock Networks and PLLs in Cyclone IV Devices chapter. (3) Including one Configuration I/O bank and two dedicated Clock input I/O banks for HSSI reference Clock input. (4) Including one Configuration I/O bank and four dedicated Clock input I/O banks for HSSI reference Clock input. (5) If PCIe X1 is implemented, the remaining transceivers in a quad can be used for other protocols at the same or different data rates. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 1–4 Cyclone IV Device Handbook, Volume 1 Package Matrix Table 1–3 shows Cyclone IV E device package offerings. Table 1–3. Cyclone IV E Device Package Offerings Package E144 F256 F484 F780 Size (mm) 22 × 22 17 × 17 23 × 23 29 × 29 Pitch (mm) 0.5 1.0 1.0 1.0 Device User I/O LVDS User I/O LVDS User I/O LVDS User I/O LVDS EP4CE6 94 22 182 68 — — — — EP4CE10 94 22 182 68 — — — — EP4CE15 — — 168 55 346 140 — — EP4CE30 — — — — 331 127 535 227 EP4CE40 — — — — 331 127 535 227 EP4CE55 — — — — 327 135 377 163 EP4CE75 — — — — 295 113 429 181 EP4CE115 — — — — 283 106 531 233 Altera Corporation Chapter 1: Cyclone IV FPGA Device Family Overview Package Matrix © November 2009 Table 1–4. Cyclone IV GX Device Package Offerings Altera Corporation Package N148 F169 F324 F484 F672 F896 Size (mm) 11 × 11 14 × 14 19 × 19 23 × 23 27 × 27 31 × 31 Pitch (mm) 0.5 1.0 1.0 1.0 1.0 1.0 LVDS XCVRs User I/O LVDS XCVRs Device User I/O LVDS XCVRs User I/O LVDS XCVRs User I/O LVDS XCVRs User I/O LVDS XCVRs User I/O EP4CGX15 72 25 2 72 25 2 — — — — — — — — — — — — EP4CGX22 — — — 72 25 2 150 64 4 — — — — — — — — — EP4CGX30 — — — 72 25 2 150 64 4 — — — — — — — — — EP4CGX50 — — — — — — — — — 290 109 4 310 140 8 — — — EP4CGX75 — — — — — — — — — 290 109 4 310 140 8 — — — EP4CGX110 — — — — — — — — — 270 93 4 393 152 8 475 216 8 EP4CGX150 — — — — — — — — — 270 93 4 393 152 8 475 216 8 Chapter 1: Cyclone IV FPGA Device Family Overview Package Matrix © November 2009 Table 1–4 shows Cyclone IV GX device package offerings, including I/O and transceiver counts. 1–5 Cyclone IV Device Handbook, Volume 1 1–6 Chapter 1: Cyclone IV FPGA Device Family Overview Cyclone IV Device Family Architecture Cyclone IV Device Family Architecture This section discusses Cyclone IV device architecture and contains the following topics: ■ “FPGA Core Fabric” ■ “I/O Features” ■ “Clock Management” ■ “External Memory Interfaces” ■ “Configuration” ■ “High-Speed Transceivers (Cyclone IV GX Devices Only)” ■ “Hard IP for PCI Express (Cyclone IV GX Devices Only)” FPGA Core Fabric Cyclone IV devices leverage the same core fabric as the very successful Cyclone series devices. The fabric consists of LEs, made of 4-input look up tables (LUTs), memory blocks, and multipliers. Each Cyclone IV device M9K memory block provides 9 Kbits of embedded SRAM memory. The M9K blocks can be configured as single port, simple dual port, or true dual port RAM, as well as FIFO buffers or ROM. They can also be configured to implement any of the data widths in Table 1–5. Table 1–5. Cyclone IV Device M9K Block Data Widths Mode Data Width Configurations Single port or simple dual port ×1, ×2, ×4, ×8/9, ×16/18, and ×32/36 True dual port ×1, ×2, ×4, ×8/9, and ×16/18 The multiplier architecture in Cyclone IV devices is the same as in existing Cyclone series devices. The embedded multiplier blocks can implement an 18 × 18 or two 9 × 9 multipliers in a single block. Altera offers a complete suite of DSP IP including FIR, FFT, and NCO functions for use with the multiplier blocks. The Quartus® II design software’s DSP Builder tool integrates MathWorks Simulink and MATLAB design environments for a streamlined DSP design flow. I/O Features Cyclone IV device I/O supports programmable bus hold, programmable pull-up resistors, programmable delay, programmable drive strength, programmable slew-rate control to optimize signal integrity, and hot socketing. Cyclone IV devices support calibrated on-chip series termination (RS OCT) or driver impedance matching (Rs) for single-ended I/O standards. In Cyclone IV GX devices, the high-speed transceiver I/Os are located on the left side of the device. The top, bottom, and right sides can implement general-purpose user I/Os. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 1: Cyclone IV FPGA Device Family Overview Cyclone IV Device Family Architecture 1–7 Table 1–6 lists the I/O standards that Cyclone IV devices support. Table 1–6. Cyclone IV Device I/O Standards Support Type I/O Standard Single-Ended I/O LVTTL, LVCMOS, SSTL, HSTL, PCI, and PCI-X Differential I/O SSTL, HSTL, LVPECL, BLVDS, LVDS, mini-LVDS, RSDS, and PPDS The LVDS SERDES is implemented in the core of the device using logic elements. Clock Management Cyclone IV devices include up to 30 global clock networks and up to eight PLLs with five outputs per PLL to provide robust clock management and synthesis. Cyclone IV device PLLs can be dynamically reconfigured in user mode to change the clock frequency or phase. Cyclone IV GX devices support two types of PLLs: Multi-purpose PLLs (MPLLs) and General-purpose PLLs (GPLLs): ■ MPLLs are used for clocking the transceiver blocks. They can also be used for general-purpose clocking when not used for transceiver clocking. ■ GPLLs can be used for general-purpose applications in the fabric and periphery, such as external memory interfaces. Some of the GPLLs can support the transceiver clocking. For more information, refer to the Clock Networks and PLLs in Cyclone IV Devices chapter. External Memory Interfaces Cyclone IV devices support SDR, DDR, DDR2 SDRAM, and QDRII SRAM interfaces on the top, bottom, and right sides of the device. Cyclone IV E devices also support these interfaces on the left side of the device. Interfaces may span two or more sides of the device to allow more flexible board design. The Altera® DDR SDRAM memory interface solution consists of a PHY interface and a memory controller. The PHY IP is provided by Altera and can be used in conjunction with your own custom memory controller or an Altera-provided memory controller. Cyclone IV devices support use of ECC bits on DDR and DDR2 SDRAM interfaces. Configuration Cyclone IV devices use SRAM cells to store configuration data. Configuration data is downloaded to the Cyclone IV device each time the device powers up. Low-cost configuration options include the Altera EPCS family serial flash devices and commodity parallel flash configuration options. These options provide the flexibility for general-purpose applications and the ability to meet specific configuration and wake-up time requirements of the applications. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 1–8 Chapter 1: Cyclone IV FPGA Device Family Overview Cyclone IV Device Family Architecture Table 1–7 shows which configuration schemes are supported by Cyclone IV devices. Table 1–7. Cyclone IV Device Configuration Schemes Devices Supported Configuration Scheme Cyclone IV GX AS, PS, JTAG, PP (1) Cyclone IV E AS, AP, PS, FPP, JTAG Note to Table 1–7: (1) The PP configuration scheme is only supported by EP4CGX50/75/110/150 devices IEEE 1149.6 (AC JTAG) is supported on all transceiver I/O pins. All other pins support IEEE 1149.1 (JTAG) for boundary scan testing. For Cyclone IV GX devices to meet the PCIe 100 ms wake-up time requirement, you must use the PS configuration mode for EP4CGX15/22/30 devices and the PP configuration mode for EP4CGX50/75/110/150 devices. High-Speed Transceivers (Cyclone IV GX Devices Only) Cyclone IV GX devices contain up to eight full duplex high-speed transceivers that can operate independently. These blocks support multiple industry-standard communication protocols, as well as Basic mode, which can be used to implement your own proprietary protocols. Each transceiver channel has its own pre-emphasis and equalization circuitry, which can be set at compile time to optimize signal integrity and reduce bit error rates. Transceiver blocks also support dynamic reconfiguration, allowing you to change data rates and protocols on-the-fly. The block diagram in Figure 1–1 shows the structure of the Cyclone IV GX transceiver. Figure 1–1. Cyclone IV GX Transceiver Channel Transmitter Channel PCS tx_dataout Serializer © November 2009 rx_datain CDR Word Aligner Receiver Channel PMA Rate Match FIFO 8B10B Decoder Byte Deserializer Byte Ordering Receiver Channel PCS RX Phase Compensation FIFO Cyclone IV Device Handbook, Volume 1 8B10B Encoder Byte Serializer PIPE Interface PCI Express Hard IP TX Phase Compensation FIFO Transceiver Channel PMA Deserializer FPGA Fabric Altera Corporation Chapter 1: Cyclone IV FPGA Device Family Overview Reference and Ordering Information 1–9 Hard IP for PCI Express (Cyclone IV GX Devices Only) Cyclone IV GX devices incorporate a single hard IP block for ×1, ×2, or ×4 PCI Express (PIPE) in each device. This hard IP block is a complete PCI Express (PIPE) protocol solution that implements PHY-MAC layer, Data Link Layer, and Transaction Layer functionality. The hard IP for the PCI Express block supports root port and end point configurations. This pre-verified hard IP block reduces risk, design time, timing closure, and verification. You can configure the block with the Quartus II software’s PCI Express Compiler, which guides you through the process step by step. Reference and Ordering Information Figure 1–2 describes the ordering codes for Cyclone IV GX devices. Figure 1–2. Cyclone IV GX Device Packaging Ordering Information EP4CGX 30 C F 19 C 7 N Family Signature Optional Suffix EP4CGX Indicates specific device shipment method ES: Engineering sample N: Lead-free devices Device Density 15, 22, 30, 50, 75 110, 150 Speed Grade 6, 7, or 8 with 6 being the fastest Transceiver Count B: 2 C: 4 D: 8 Operating Temperature C: Commercial temperature (tJ = 0° C to 85° C) Package Type N: Quad Flat Pack No Lead (QFN) F: FineLine BGA (FBGA) Package I: Industrial temperature (tJ = -40° C to 100° C) 11 = 148 pins 14 = 169 pins 19 = 324 pins 23 = 484 pins 27 = 672 pins 31 = 896 pins Chapter Revision History Table 1–8 shows the revision history for this chapter. Table 1–8. Chapter Revision History Date November 2009 © November 2009 Version 1.0 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 1 1–10 Cyclone IV Device Handbook, Volume 1 Chapter 1: Cyclone IV FPGA Device Family Overview Chapter Revision History © November 2009 Altera Corporation 2. Logic Elements and Logic Array Blocks in Cyclone IV Devices CYIV-51002-1.0 This chapter contains feature definitions for logic elements (LEs) and logic array blocks (LABs). Details are provided on how LEs work, how LABs contain groups of LEs, and how LABs interface with the other blocks in Cyclone ® IV devices. Logic Elements Logic elements (LEs) are the smallest units of logic in the Cyclone IV device architecture. LEs are compact and provide advanced features with efficient logic usage. Each LE has the following features: © November 2009 ■ A four-input look-up table (LUT), which can implement any function of four variables ■ A programmable register ■ A carry chain connection ■ A register chain connection ■ The ability to drive the following interconnects: ■ Local ■ Row ■ Column ■ Register chain ■ Direct link ■ Register packing support ■ Register feedback support Altera Corporation Cyclone IV Device Handbook, Volume 1 2–2 Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices Logic Elements Figure 2–1 shows the LEs for Cyclone IV devices. Figure 2–1. Cyclone IV Device LEs Register Chain Routing from previous LE LE Carry-In data 1 data 2 data 3 Register Bypass LAB-Wide Synchronous LAB-Wide Programmable Synchronous Load Register Clear Synchronous Load and Clear Logic Look-Up Table Carry Chain (LUT) data 4 D Q ENA CLRN labclr1 labclr2 Chip-Wide Reset Register Feedback Asynchronous Clear Logic Row, Column, And Direct Link Routing Row, Column, And Direct Link Routing Local Routing (DEV_CLRn) Clock & Clock Enable Select LE Carry-Out Register Chain Output labclk1 labclk2 labclkena1 labclkena2 LE Features You can configure the programmable register of each LE for D, T, JK, or SR flipflop operation. Each register has data, clock, clock enable, and clear inputs. Signals that use the global clock network, general-purpose I/O pins, or any internal logic can drive the clock and clear control signals of the register. Either general-purpose I/O pins or the internal logic can drive the clock enable. For combinational functions, the LUT output bypasses the register and drives directly to the LE outputs. Each LE has three outputs that drive the local, row, and column routing resources. The LUT or register output independently drives these three outputs. Two LE outputs drive the column or row and direct link routing connections, while one LE drives the local interconnect resources. This allows the LUT to drive one output while the register drives another output. This feature, called register packing, improves device utilization because the device can use the register and the LUT for unrelated functions. The LAB-wide synchronous load control signal is not available when using register packing. For more information about the synchronous load control signal, refer to “LAB Control Signals” on page 2–6. The register feedback mode allows the register output to feed back into the LUT of the same LE to ensure that the register is packed with its own fan-out LUT, providing another mechanism for improved fitting. The LE can also drive out registered and unregistered versions of the LUT output. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices LE Operating Modes 2–3 In addition to the three general routing outputs, LEs in an LAB have register chain outputs, which allows registers in the same LAB to cascade together. The register chain output allows the LUTs to be used for combinational functions and the registers to be used for an unrelated shift register implementation. These resources speed up connections between LABs while saving local interconnect resources. LE Operating Modes Cyclone IV LEs operate in the following modes: ■ Normal mode ■ Arithmetic mode The Quartus® II software automatically chooses the appropriate mode for common functions, such as counters, adders, subtractors, and arithmetic functions, in conjunction with parameterized functions such as the library of parameterized modules (LPM) functions. You can also create special-purpose functions that specify which LE operating mode to use for optimal performance, if required. Normal Mode Normal mode is suitable for general logic applications and combinational functions. In normal mode, four data inputs from the LAB local interconnect are inputs to a four-input LUT (Figure 2–2). The Quartus II Compiler automatically selects the carry-in (cin) or the data3 signal as one of the inputs to the LUT. LEs in normal mode support packed registers and register feedback. Figure 2–2 shows LEs in normal mode. Figure 2–2. Cyclone IV Device LEs in Normal Mode Register Chain Connection sload sclear (LAB Wide) (LAB Wide) Packed Register Input D Row, Column, and Direct Link Routing ENA CLRN Row, Column, and Direct Link Routing Q data1 data2 data3 cin (from cout of previous LE) data4 Four-Input LUT clock (LAB Wide) ena (LAB Wide) Local Routing aclr (LAB Wide) Register Bypass © November 2009 Altera Corporation Register Feedback Register Chain Output Cyclone IV Device Handbook, Volume 1 2–4 Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices Logic Array Blocks Arithmetic Mode Arithmetic mode is ideal for implementing adders, counters, accumulators, and comparators. An LE in arithmetic mode implements a 2-bit full adder and basic carry chain (Figure 2–3). LEs in arithmetic mode can drive out registered and unregistered versions of the LUT output. Register feedback and register packing are supported when LEs are used in arithmetic mode. Figure 2–3 shows LEs in arithmetic mode. Figure 2–3. Cyclone IV Device LEs in Arithmetic Mode Packed Register Input Register Chain Connection sload sclear (LAB Wide) (LAB Wide) data4 data1 data2 Three-Input LUT cin (from cout of previous LE) Row, Column, and Direct link routing ENA CLRN Row, Column, and Direct link routing Q data3 Three-Input LUT D clock (LAB Wide) ena (LAB Wide) Local Routing aclr (LAB Wide) cout Register Chain Output Register Bypass Register Feedback The Quartus II Compiler automatically creates carry chain logic during design processing. You can also manually create the carry chain logic during design entry. Parameterized functions, such as LPM functions, automatically take advantage of carry chains for the appropriate functions. The Quartus II Compiler creates carry chains longer than 16 LEs by automatically linking LABs in the same column. For enhanced fitting, a long carry chain runs vertically, which allows fast horizontal connections to M9K memory blocks or embedded multipliers through direct link interconnects. For example, if a design has a long carry chain in an LAB column next to a column of M9K memory blocks, any LE output can feed an adjacent M9K memory block through the direct link interconnect. If the carry chains run horizontally, any LAB which is not next to the column of M9K memory blocks uses other row or column interconnects to drive a M9K memory block. A carry chain continues as far as a full column. Logic Array Blocks Logic array blocks (LABs) contain groups of LEs. Topology Each LAB consists of the following features: ■ 16 LEs Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices Logic Array Blocks ■ LAB control signals ■ LE carry chains ■ Register chains ■ Local interconnect 2–5 The local interconnect transfers signals between LEs in the same LAB. Register chain connections transfer the output of one LE register to the adjacent LE register in an LAB. The Quartus II Compiler places associated logic in an LAB or adjacent LABs, allowing the use of local and register chain connections for performance and area efficiency. Figure 2–4 shows the LAB structure for Cyclone IV devices. Figure 2–4. Cyclone IV Device LAB Structure Row Interconnect Column Interconnect Direct link interconnect from adjacent block Direct link interconnect from adjacent block Direct link interconnect to adjacent block Direct link interconnect to adjacent block LAB Local Interconnect LAB Interconnects The LAB local interconnect is driven by column and row interconnects and LE outputs in the same LAB. Neighboring LABs, phase-locked loops (PLLs), M9K RAM blocks, and embedded multipliers from the left and right can also drive the local interconnect of a LAB through the direct link connection. The direct link connection feature minimizes the use of row and column interconnects, providing higher performance and flexibility. Each LE can drive up to 48 LEs through fast local and direct link interconnects. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 2–6 Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices LAB Control Signals Figure 2–5 shows the direct link connection. Figure 2–5. Cyclone IV Device Direct Link Connection Direct link interconnect from left LAB, M9K memory block, embedded multiplier, PLL, or IOE output Direct link interconnect from right LAB, M9K memory block, embedded multiplier, PLL, or IOE output Direct link interconnect to right Direct link interconnect to left Local Interconnect LAB LAB Control Signals Each LAB contains dedicated logic for driving control signals to its LEs. The control signals include: ■ Two clocks ■ Two clock enables ■ Two asynchronous clears ■ One synchronous clear ■ One synchronous load You can use up to eight control signals at a time. Register packing and synchronous load cannot be used simultaneously. Each LAB can have up to four non-global control signals. You can use additional LAB control signals as long as they are global signals. Synchronous clear and load signals are useful for implementing counters and other functions. The synchronous clear and synchronous load signals are LAB-wide signals that affect all registers in the LAB. Each LAB can use two clocks and two clock enable signals. The clock and clock enable signals of each LAB are linked. For example, any LE in a particular LAB using the labclk1 signal also uses the labclkena1. If the LAB uses both the rising and falling edges of a clock, it also uses both LAB-wide clock signals. Deasserting the clock enable signal turns off the LAB-wide clock. The LAB row clocks [5..0] and LAB local interconnect generate the LAB-wide control signals. The MultiTrack interconnect inherent low skew allows clock and control signal distribution in addition to data distribution. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices Chapter Revision History 2–7 Figure 2–6 shows the LAB control signal generation circuit. Figure 2–6. Cyclone IV Device LAB-Wide Control Signals Dedicated LAB Row Clocks 6 Local Interconnect Local Interconnect Local Interconnect Local Interconnect labclkena2 labclkena1 labclk1 labclk2 synclr labclr1 syncload labclr2 LAB-wide signals control the logic for the clear signal of the register. The LE directly supports an asynchronous clear function. Each LAB supports up to two asynchronous clear signals (labclr1 and labclr2). A LAB-wide asynchronous load signal to control the logic for the preset signal of the register is not available. The register preset is achieved with a NOT gate push-back technique. Cyclone IV devices only support either a preset or asynchronous clear signal. In addition to the clear port, Cyclone IV devices provide a chip-wide reset pin (DEV_CLRn) that resets all registers in the device. An option set before compilation in the Quartus II software controls this pin. This chip-wide reset overrides all other control signals. Chapter Revision History Table 2–1 shows the revision history for this chapter. Table 2–1. Chapter Revision History Date November 2009 © November 2009 Version 1.0 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 1 2–8 Cyclone IV Device Handbook, Volume 1 Chapter 2: Logic Elements and Logic Array Blocks in Cyclone IV Devices Chapter Revision History © November 2009 Altera Corporation 3. Memory Blocks in Cyclone IV Devices CYIV-51003-1.0 Cyclone® IV devices feature embedded memory structures to address the on-chip memory needs of Altera® Cyclone IV device designs. The embedded memory structure consists of columns of M9K memory blocks that you can configure to provide various memory functions, such as RAM, shift registers, ROM, and FIFO buffers. This chapter contains the following sections: ■ “Memory Modes” on page 3–7 ■ “Clocking Modes” on page 3–14 ■ “Design Considerations” on page 3–15 Overview M9K blocks support the following features: © November 2009 ■ 8,192 memory bits per block (9,216 bits per block including parity) ■ Independent read-enable (rden) and write-enable (wren) signals for each port ■ Packed mode in which the M9K memory block is split into two 4.5 K single-port RAMs ■ Variable port configurations ■ Single-port and simple dual-port modes support for all port widths ■ True dual-port (one read and one write, two reads, or two writes) operation ■ Byte enables for data input masking during writes ■ Two clock-enable control signals for each port (port A and port B) ■ Initialization file to pre-load memory content in RAM and ROM modes Altera Corporation Cyclone IV Device Handbook, Volume 1 3–2 Chapter 3: Memory Blocks in Cyclone IV Devices Overview Table 3–1 lists the features supported by the M9K memory. Table 3–1. Summary of M9K Memory Features Feature M9K Blocks 8192 × 1 4096 × 2 2048 × 4 1024 × 8 Configurations (depth × width) 1024 × 9 512 × 16 512 × 18 256 × 32 256 × 36 Parity bits v Byte enable v Packed mode v Address clock enable v Single-port mode v Simple dual-port mode v True dual-port mode v Embedded shift register mode (1) v ROM mode v FIFO buffer (1) v Simple dual-port mixed width support v True dual-port mixed width support (2) v Memory initialization file (.mif) v Mixed-clock mode v Power-up condition Outputs cleared Register asynchronous clears Latch asynchronous clears Write or read operation triggering Read address registers and output registers only Output latches only Write and read: Rising clock edges Same-port read-during-write Outputs set to Old Data or New Data Mixed-port read-during-write Outputs set to Old Data or Don’t Care Notes to Table 3–1: (1) FIFO buffers and embedded shift registers that require external logic elements (LEs) for implementing control logic. (2) Width modes of ×32 and ×36 are not available. f For information about the number of M9K memory blocks for Cyclone IV devices, refer to the Cyclone IV Device Family Overview chapter in volume 1 of the Cyclone IV Device Handbook. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Overview 3–3 Control Signals The clock-enable control signal controls the clock entering the input and output registers and the entire M9K memory block. This signal disables the clock so that the M9K memory block does not see any clock edges and does not perform any operations. The rden and wren control signals control the read and write operations for each port of M9K memory blocks. You can disable the rden or wren signals independently to save power whenever the operation is not required. Parity Bit Support Parity checking for error detection is possible with the parity bit along with internal logic resources. Cyclone IV devices M9K memory blocks support a parity bit for each storage byte. You can use this bit as either a parity bit or as an additional data bit. No parity function is actually performed on this bit. Byte Enable Support Cyclone IV devices M9K memory blocks support byte enables that mask the input data so that only specific bytes of data are written. The unwritten bytes retain the previous written value. The wren signals, along with the byte-enable (byteena) signals, control the write operations of the RAM block. The default value of the byteena signals is high (enabled), in which case writing is controlled only by the wren signals. There is no clear port to the byteena registers. M9K blocks support byte enables when the write port has a data width of ×16, ×18, ×32, or ×36 bits. Byte enables operate in one-hot manner, with the LSB of the byteena signal corresponding to the least significant byte of the data bus. For example, if byteena = 01 and you are using a RAM block in ×18 mode, data[8..0] is enabled and data[17..9] is disabled. Similarly, if byteena = 11, both data[8..0] and data[17..9] are enabled. Byte enables are active high. Table 3–2 lists the byte selection. Table 3–2. byteena for Cyclone IV Devices M9K Blocks (Note 1) Affected Bytes byteena[3..0] datain ×16 datain ×18 datain ×32 datain ×36 [0] = 1 [7..0] [8..0] [7..0] [8..0] [1] = 1 [15..8] [17..9] [15..8] [17..9] [2] = 1 — — [23..16] [26..18] [3] = 1 — — [31..24] [35..27] Note to Table 3–2: (1) Any combination of byte enables is possible. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 3–4 Chapter 3: Memory Blocks in Cyclone IV Devices Overview Figure 3–1 shows how the wren and byteena signals control the RAM operations. Figure 3–1. Cyclone IV Devices byteena Functional Waveform (Note 1) inclock wren rden an address data a0 a1 XXXX byteena contents at a1 10 a1 01 a2 XXXX 11 FFFF XX ABFF FFFF FFCD FFFF contents at a2 q (asynch) a0 ABCD XX contents at a0 a2 doutn ABFF ABCD FFCD ABCD ABFF FFCD ABCD Note to Figure 3–1: (1) For this functional waveform, New Data mode is selected. When a byteena bit is deasserted during a write cycle, the old data in the memory appears in the corresponding data-byte output. When a byteena bit is asserted during a write cycle, the corresponding data-byte output depends on the setting chosen in the Quartus® II software. The setting can either be the newly written data or the old data at that location. Packed Mode Support Cyclone IV devices M9K memory blocks support packed mode. You can implement two single-port memory blocks in a single block under the following conditions: ■ Each of the two independent block sizes is less than or equal to half of the M9K block size. The maximum data width for each independent block is 18 bits wide. ■ Each of the single-port memory blocks is configured in single-clock mode. For more information about packed mode support, refer to “Single-Port Mode” on page 3–7 and “Single-Clock Mode” on page 3–15. Address Clock Enable Support Cyclone IV devices M9K memory blocks support an active-low address clock enable, which holds the previous address value for as long as the addressstall signal is high (addressstall = '1'). When you configure M9K memory blocks in dual-port mode, each port has its own independent address clock enable. Figure 3–2 shows an address clock enable block diagram. The address register output feeds back to its input using a multiplexer. The multiplexer output is selected by the address clock enable (addressstall) signal. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Overview 3–5 Figure 3–2. Cyclone IV Devices Address Clock Enable Block Diagram address[0] address[0] register address[0] address[N] address[N] register address[N] addressstall clock The address clock enable is typically used to improve the effectiveness of cache memory applications during a cache-miss. The default value for the address clock enable signals is low. Figure 3–3 and Figure 3–4 show the address clock enable waveform during read and write cycles, respectively. Figure 3–3. Cyclone IV Devices Address Clock Enable During Read Cycle Waveform inclock rdaddress a0 a1 a2 a3 a4 a5 a6 rden addressstall latched address (inside memory) an q (synch) doutn-1 q (asynch) © November 2009 Altera Corporation doutn a1 a0 doutn dout0 dout0 dout1 dout1 dout1 dout1 dout1 a4 a5 dout1 dout4 dout4 dout5 Cyclone IV Device Handbook, Volume 1 3–6 Chapter 3: Memory Blocks in Cyclone IV Devices Overview Figure 3–4. Cyclone IV Devices Address Clock Enable During Write Cycle Waveform inclock wraddress a0 a1 a2 a3 a4 a5 a6 00 01 02 03 04 05 06 data wren addressstall latched address (inside memory) contents at a0 contents at a1 an a1 a0 a4 a5 00 XX XX 01 contents at a2 XX contents at a3 XX contents at a4 03 02 04 XX XX contents at a5 05 Mixed-Width Support M9K memory blocks support mixed data widths. When using simple dual-port, true dual-port, or FIFO modes, mixed width support allows you to read and write different data widths to an M9K memory block. For more information about the different widths supported per memory mode, refer to “Memory Modes” on page 3–7. Asynchronous Clear Cyclone IV devices support asynchronous clears for read address registers, output registers, and output latches only. Input registers other than read address registers are not supported. When applied to output registers, the asynchronous clear signal clears the output registers and the effects are immediately seen. If your RAM does not use output registers, you can still clear the RAM outputs using the output latch asynchronous clear feature. 1 Asserting asynchronous clear to the read address register during a read operation may corrupt the memory content. Figure 3–5 shows the functional waveform for the asynchronous clear feature. Figure 3–5. Output Latch Asynchronous Clear Waveform clk aclr aclr at latch q Cyclone IV Device Handbook, Volume 1 a1 a2 a0 a1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes 1 f 3–7 You can selectively enable asynchronous clears per logical memory using the Quartus II RAM MegaWizard™ Plug-In Manager. For more information, refer to the RAM Megafunction User Guide. There are three ways to reset registers in the M9K blocks: ■ Power up the device ■ Use the aclr signal for output register only ■ Assert the device-wide reset signal using the DEV_CLRn option Memory Modes Cyclone IV devices M9K memory blocks allow you to implement fully-synchronous SRAM memory in multiple modes of operation. Cyclone IV devices M9K memory blocks do not support asynchronous (unregistered) memory inputs. M9K memory blocks support the following modes: 1 ■ Single-port ■ Simple dual-port ■ True dual-port ■ Shift-register ■ ROM ■ FIFO Violating the setup or hold time on the M9K memory block input registers may corrupt memory contents. This applies to both read and write operations. Single-Port Mode Single-port mode supports non-simultaneous read and write operations from a single address. Figure 3–6 shows the single-port memory configuration for Cyclone IV devices M9K memory blocks. Figure 3–6. Single-Port Memory (Note 1), (2) data[ ] address[ ] wren byteena[] addressstall inclock inclocken rden aclr q[] outclock outclocken Notes to Figure 3–6: (1) You can implement two single-port memory blocks in a single M9K block. (2) For more information, refer to “Packed Mode Support” on page 3–4. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 3–8 Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes During a write operation, the behavior of the RAM outputs is configurable. If you activate rden during a write operation, the RAM outputs show either the new data being written or the old data at that address. If you perform a write operation with rden deactivated, the RAM outputs retain the values they held during the most recent active rden signal. To choose the desired behavior, set the Read-During-Write option to either New Data or Old Data in the RAM MegaWizard Plug-In Manager in the Quartus II software. For more information about read-during-write mode, refer to “Read-During-Write Operations” on page 3–15. The port width configurations for M9K blocks in single-port mode are as follow: ■ 8192 × 1 ■ 4096 × 2 ■ 2048 × 4 ■ 1024 × 8 ■ 1024 × 9 ■ 512 × 16 ■ 512 × 18 ■ 256 × 32 ■ 256 × 36 Figure 3–7 shows a timing waveform for read and write operations in single-port mode with unregistered outputs. Registering the outputs of the RAM simply delays the q output by one clock cycle. Figure 3–7. Cyclone IV Devices Single-Port Mode Timing Waveform clk_a wren_a rden_a address_a data_a q_a (old data) q_a (new data) Cyclone IV Device Handbook, Volume 1 a0 A a1 B C D E F a0(old data) A B a1(old data) D E A B C D E F © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes 3–9 Simple Dual-Port Mode Simple dual-port mode supports simultaneous read and write operations to different locations. Figure 3–8 shows the simple dual-port memory configuration. Figure 3–8. Cyclone IV Devices Simple Dual-Port Memory data[ ] wraddress[ ] wren byteena[] wr_addressstall wrclock wrclocken aclr (Note 1) rdaddress[ ] rden q[ ] rd_addressstall rdclock rdclocken Note to Figure 3–8: (1) Simple dual-port RAM supports input or output clock mode in addition to the read or write clock mode shown. Cyclone IV devices M9K memory blocks support mixed-width configurations, allowing different read and write port widths. Table 3–3 lists mixed-width configurations. Table 3–3. Cyclone IV Devices M9K Block Mixed-Width Configurations (Simple Dual-Port Mode) Write Port 8192 × 1 4096 × 2 2048 × 4 1024 × 8 512 × 16 256 × 32 1024 × 9 512 × 18 256 × 36 8192 × 1 v v v v v v — — — 4096 × 2 v v v v v v — — — 2048 × 4 v v v v v v — — — 1024 × 8 v v v v v v — — — 512 × 16 v v v v v v — — — 256 × 32 v v v v v v — — — 1024 × 9 — — — — — — v v v 512 × 18 — — — — — — v v v 256 × 36 — — — — — — v v v Read Port In simple dual-port mode, M9K memory blocks support separate wren and rden signals. You can save power by keeping the rden signal low (inactive) when not reading. Read-during-write operations to the same address can either output “Don’t Care” data at that location or output “Old Data”. To choose the desired behavior, set the Read-During-Write option to either Don’t Care or Old Data in the RAM MegaWizard Plug-In Manager in the Quartus II software. For more information about this behavior, refer to “Read-During-Write Operations” on page 3–15. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 3–10 Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes Figure 3–9 shows the timing waveform for read and write operations in simple dual-port mode with unregistered outputs. Registering the outputs of the RAM simply delays the q output by one clock cycle. Figure 3–9. Cyclone IV Devices Simple Dual-Port Timing Waveform wrclock wren wraddress an-1 data din-1 a0 an a1 a2 a3 din a4 a5 din4 din5 a6 din6 rdclock rden rdaddress q (asynch) bn doutn-1 b0 doutn b1 b2 b3 dout0 True Dual-Port Mode True dual-port mode supports any combination of two-port operations: two reads, two writes, or one read and one write, at two different clock frequencies. Figure 3–10 shows Cyclone IV devices true dual-port memory configuration. Figure 3–10. Cyclone IV Devices True Dual-Port Memory data_a[ ] address_a[ ] wren_a byteena_a[] addressstall_a clock_a clocken_a rden_a aclr_a q_a[] (Note 1) data_b[ ] address_b[] wren_b byteena_b[] addressstall_b clock_b clocken_b rden_b aclr_b q_b[] Note to Figure 3–10: (1) True dual-port memory supports input or output clock mode in addition to the independent clock mode shown. 1 The widest bit configuration of the M9K blocks in true dual-port mode is 512 × 16-bit (18-bit with parity). Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes 3–11 Table 3–4 lists the possible M9K block mixed-port width configurations. Table 3–4. Cyclone IV Devices M9K Block Mixed-Width Configurations (True Dual-Port Mode) Write Port 8192 × 1 4096 × 2 2048 × 4 1024 × 8 512 × 16 1024 × 9 512 × 18 8192 × 1 v v v v v — — 4096 × 2 v v v v v — — 2048 × 4 v v v v v — — Read Port 1024 × 8 v v v v v — — 512 × 16 v v v v v — — 1024 × 9 — — — — — v v 512 × 18 — — — — — v v In true dual-port mode, M9K memory blocks support separate wren and rden signals. You can save power by keeping the rden signal low (inactive) when not reading. Read-during-write operations to the same address can either output “New Data” at that location or “Old Data”. To choose the desired behavior, set the Read-During-Write option to either New Data or Old Data in the RAM MegaWizard Plug-In Manager in the Quartus II software. For more information about this behavior, refer to “Read-During-Write Operations” on page 3–15. In true dual-port mode, you can access any memory location at any time from either port A or port B. However, when accessing the same memory location from both ports, you must avoid possible write conflicts. When you attempt to write to the same address location from both ports at the same time, a write conflict happens. This results in unknown data being stored to that address location. There is no conflict resolution circuitry built into the Cyclone IV devices M9K memory blocks. You must handle address conflicts external to the RAM block. Figure 3–11 shows true dual-port timing waveforms for the write operation at port A and read operation at port B. Registering the outputs of the RAM simply delays the q outputs by one clock cycle. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 3–12 Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes Figure 3–11. Cyclone IV Devices True Dual-Port Timing Waveform clk_a wren_a address_a data_a an-1 an din-1 din a0 a1 a2 a3 a4 a5 a6 din4 din5 din6 rden_a q_a (asynch) din-1 din dout0 dout1 dout2 dout3 din5 din4 clk_b wren_b address_b bn b0 b1 b2 b3 doutn dout0 dout1 dout2 rden_b q_b (asynch) doutn-1 Shift Register Mode Cyclone IV devices M9K memory blocks can implement shift registers for digital signal processing (DSP) applications, such as finite impulse response (FIR) filters, pseudo-random number generators, multi-channel filtering, and auto-correlation and cross-correlation functions. These and other DSP applications require local data storage, traditionally implemented with standard flipflops that quickly exhaust many logic cells for large shift registers. A more efficient alternative is to use embedded memory as a shift register block, which saves logic cell and routing resources. The size of a (w × m × n) shift register is determined by the input data width (w), the length of the taps (m), and the number of taps (n), and must be less than or equal to the maximum number of memory bits, which is 9,216 bits. In addition, the size of (w × n) must be less than or equal to the maximum width of the block, which is 36 bits. If you need a larger shift register, you can cascade the M9K memory blocks. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Memory Modes 3–13 Figure 3–12 shows the Cyclone IV devices M9K memory block in shift register mode. Figure 3–12. Cyclone IV Devices Shift Register Mode Configuration w × m × n Shift Register m-Bit Shift Register W W m-Bit Shift Register W W n Number of Taps m-Bit Shift Register W W m-Bit Shift Register W W ROM Mode Cyclone IV devices M9K memory blocks support ROM mode. A .mif initializes the ROM contents of these blocks. The address lines of the ROM are registered. The outputs can be registered or unregistered. The ROM read operation is identical to the read operation in the single-port RAM configuration. FIFO Buffer Mode Cyclone IV devices M9K memory blocks support single-clock or dual-clock FIFO buffers. Dual clock FIFO buffers are useful when transferring data from one clock domain to another clock domain. Cyclone IV devices M9K memory blocks do not support simultaneous read and write from an empty FIFO buffer. f © November 2009 For more information about FIFO buffers, refer to the Single- and Dual-Clock FIFO Megafunction User Guide. Altera Corporation Cyclone IV Device Handbook, Volume 1 3–14 Chapter 3: Memory Blocks in Cyclone IV Devices Clocking Modes Clocking Modes Cyclone IV devices M9K memory blocks support the following clocking modes: ■ Independent ■ Input or output ■ Read or write ■ Single-clock When using read or write clock mode, if you perform a simultaneous read or write to the same address location, the output read data is unknown. If you require the output data to be a known value, use either single-clock mode or I/O clock mode and choose the appropriate read-during-write behavior in the MegaWizard Plug-In Manager. 1 Violating the setup or hold time on the memory block input registers might corrupt the memory contents. This applies to both read and write operations. 1 Asynchronous clears are available on read address registers, output registers, and output latches only. Table 3–5 lists the clocking mode versus memory mode support matrix. Table 3–5. Cyclone IV Devices Memory Clock Modes True Dual-Port Mode Simple Dual-Port Mode Single-Port Mode ROM Mode FIFO Mode Independent v — — v — Input or output v v v v — Read or write — v — — v Single-clock v v v v v Clocking Mode Independent Clock Mode Cyclone IV devices M9K memory blocks can implement independent clock mode for true dual-port memories. In this mode, a separate clock is available for each port (port A and port B). clock A controls all registers on the port A side, while clock B controls all registers on the port B side. Each port also supports independent clock enables for port A and B registers. Input or Output Clock Mode Cyclone IV devices M9K memory blocks can implement input or output clock mode for FIFO, single-port, true, and simple dual-port memories. In this mode, an input clock controls all input registers to the memory block including data, address, byteena, wren, and rden registers. An output clock controls the data-output registers. Each memory block port also supports independent clock enables for input and output registers. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Design Considerations 3–15 Read or Write Clock Mode Cyclone IV devices M9K memory blocks can implement read or write clock mode for FIFO and simple dual-port memories. In this mode, a write clock controls the data inputs, write address, and wren registers. Similarly, a read clock controls the data outputs, read address, and rden registers. M9K memory blocks support independent clock enables for both the read and write clocks. When using read or write mode, if you perform a simultaneous read or write to the same address location, the output read data is unknown. If you require the output data to be a known value, use either single-clock mode, input clock mode, or output clock mode and choose the appropriate read-during-write behavior in the MegaWizard Plug-In Manager. Single-Clock Mode Cyclone IV devices M9K memory blocks can implement single-clock mode for FIFO, ROM, true dual-port, simple dual-port, and single-port memories. In this mode, you can control all registers of the M9K memory block with a single clock together with clock enable. Design Considerations This section describes designing with M9K memory blocks. Read-During-Write Operations “Same-Port Read-During-Write Mode” on page 3–16 and “Mixed-Port Read-DuringWrite Mode” on page 3–17 describe the functionality of the various RAM configurations when reading from an address during a write operation at that same address. There are two read-during-write data flows: same-port and mixed-port. Figure 3–13 shows the difference between these flows. Figure 3–13. Cyclone IV Devices Read-During-Write Data Flow write_a Port A data in Port B data in write_b Mixed-port data flow Same-port data flow read_a © November 2009 Altera Corporation Port A data out Port B data out read_b Cyclone IV Device Handbook, Volume 1 3–16 Chapter 3: Memory Blocks in Cyclone IV Devices Design Considerations Same-Port Read-During-Write Mode This mode applies to a single-port RAM or the same port of a true dual-port RAM. In the same port read-during-write mode, there are two output choices: New Data mode (or flow-through) and Old Data mode. In New Data mode, new data is available on the rising edge of the same clock cycle on which it was written. In Old Data mode, the RAM outputs reflect the old data at that address before the write operation proceeds. When using New Data mode together with byteena, you can control the output of the RAM. When byteena is high, the data written into the memory passes to the output (flow-through). When byteena is low, the masked-off data is not written into the memory and the old data in the memory appears on the outputs. Therefore, the output can be a combination of new and old data determined by byteena. Figure 3–14 and Figure 3–15 show sample functional waveforms of same port read-during-write behavior with both New Data and Old Data modes, respectively. Figure 3–14. Same Port Read-During Write: New Data Mode clk_a wren_a rden_a address_a data_a a0 A q_a (asynch) a1 B A C B D C E D F E F Figure 3–15. Same Port Read-During-Write: Old Data Mode clk_a wren_a rden_a address_a data_a q_a (asynch) Cyclone IV Device Handbook, Volume 1 a0 A a0(old data) a1 B C A D B E a1(old data) F D © November 2009 E Altera Corporation Chapter 3: Memory Blocks in Cyclone IV Devices Design Considerations 3–17 Mixed-Port Read-During-Write Mode This mode applies to a RAM in simple or true dual-port mode, which has one port reading and the other port writing to the same address location with the same clock. In this mode, you also have two output choices: Old Data mode or Don't Care mode. In Old Data mode, a read-during-write operation to different ports causes the RAM outputs to reflect the old data at that address location. In Don't Care mode, the same operation results in a “Don't Care” or unknown value on the RAM outputs. f For more information about how to implement the desired behavior, refer to the RAM Megafunction User Guide. Figure 3–16 shows a sample functional waveform of mixed port read-during-write behavior for Old Data mode. In Don't Care mode, the old data is replaced with “Don't Care”. Figure 3–16. Mixed Port Read-During-Write: Old Data Mode clk_a&b wren_a address_a data_a a b A B C D E F rden_b address_b q_b (asynch) 1 a a (old data) b A B b (old data) D E For mixed-port read-during-write operation with dual clocks, the relationship between the clocks determines the output behavior of the memory. If you use the same clock for the two clocks, the output is the old data from the address location. However, if you use different clocks, the output is unknown during the mixed-port read-during-write operation. This unknown value may be the old or new data at the address location, depending on whether the read happens before or after the write. Conflict Resolution When you are using M9K memory blocks in true dual-port mode, it is possible to attempt two write operations to the same memory location (address). Because there is no conflict resolution circuitry built into M9K memory blocks, this results in unknown data being written to that location. Therefore, you must implement conflict-resolution logic external to the M9K memory block. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 3–18 Chapter 3: Memory Blocks in Cyclone IV Devices Chapter Revision History Power-Up Conditions and Memory Initialization The M9K memory block outputs of Cyclone IV devices power up to zero (cleared) regardless of whether the output registers are used or bypassed. All M9K memory blocks support initialization using a .mif. You can create .mifs in the Quartus II software and specify their use using the RAM MegaWizard Plug-In Manager when instantiating memory in your design. Even if memory is pre-initialized (for example, using a .mif), it still powers up with its outputs cleared. Only the subsequent read after power up outputs the pre-initialized values. f For more information about .mifs, refer to the RAM Megafunction User Guide and the Quartus II Handbook. Power Management The M9K memory block clock enables of Cyclone IV devices allow you to control clocking of each M9K memory block to reduce AC power consumption. Use the rden signal to ensure that read operations only occur when necessary. If your design does not require read-during-write, reduce power consumption by deasserting the rden signal during write operations or any period when there are no memory operations. The Quartus II software automatically powers down any unused M9K memory blocks to save static power. Chapter Revision History Table 3–6 shows the revision history for this chapter. Table 3–6. Chapter Revision History Date November 2009 Version 1.0 Cyclone IV Device Handbook, Volume 1 Changes Made Initial release. © November 2009 Altera Corporation 4. Embedded Multipliers in Cyclone IV Devices CYIV-51004-1.0 Cyclone® IV devices include a combination of on-chip resources and external interfaces that help to increase performance, reduce system cost, and lower the power consumption of digital signal processing (DSP) systems. Cyclone IV devices, either alone or as DSP device co-processors, are used to improve price-to-performance ratios of DSP systems. Particular focus is placed on optimizing Cyclone IV devices for applications that benefit from an abundance of parallel processing resources, which include video and image processing, intermediate frequency (IF) modems used in wireless communications systems, and multi-channel communications and video systems. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. This chapter contains the following sections: ■ “Embedded Multiplier Block Overview” on page 4–1 ■ “Architecture” on page 4–2 ■ “Operational Modes” on page 4–4 Embedded Multiplier Block Overview Figure 4–1 shows one of the embedded multiplier columns with the surrounding logic array blocks (LABs). The embedded multiplier is configured as either one 18 × 18 multiplier or two 9 × 9 multipliers. For multiplications greater than 18 × 18, the Quartus® II software cascades multiple embedded multiplier blocks together. There are no restrictions on the data width of the multiplier, but the greater the data width, the slower the multiplication process. Figure 4–1. Embedded Multipliers Arranged in Columns with Adjacent LABs Embedded Multiplier Column 1 LAB Row © November 2009 Altera Corporation Embedded Multiplier Cyclone IV Device Handbook, Volume 1 4–2 Chapter 4: Embedded Multipliers in Cyclone IV Devices Architecture Table 4–1 shows the number of embedded multipliers and the multiplier modes that can be implemented in each Cyclone IV device. Table 4–1. Number of Embedded Multipliers in Cyclone IV Devices Device Embedded Multipliers 9×9 Multipliers (1) 18 × 18 Multipliers (1) Software Multipliers (2) Total Multipliers (3) EP4CGX15 0 0 0 60 60 EP4CGX22 40 80 40 84 124 EP4CGX30 80 160 80 120 200 EP4CGX50 140 280 140 278 418 EP4CGX75 198 396 198 462 660 EP4CGX110 280 560 280 610 890 EP4CGX150 360 720 360 720 1080 Device Family Cyclone IV Notes to Table 4–1: (1) These columns show the number of 9 × 9 or 18 × 18 multipliers for each device. (2) Soft multipliers are implemented in sum of multiplication mode. M9K memory blocks are configured with 18-bit data widths to support 16-bit coefficients. The sum of the coefficients requires 18 bits of resolution to account for overflow. (3) The total number of multipliers may vary, depending on the multiplier mode used. In addition to the embedded multipliers in Cyclone IV devices, you can implement soft multipliers by using the M9K memory blocks as look-up tables (LUTs). The LUTs contain partial results from the multiplication of input data with coefficients that implement variable depth and width high-performance soft multipliers for low-cost, high-volume DSP applications. The availability of soft multipliers increases the number of available multipliers in the device. f For more information about M9K memory blocks, refer to the Memory Blocks in Cyclone IV Devices chapter in volume 1 of the Cyclone IV Device Handbook. f For more information about soft multipliers, refer to AN 306: Implementing Multipliers in FPGA Devices. Architecture Each embedded multiplier consists of the following elements: ■ Multiplier stage ■ Input and output registers ■ Input and output interfaces Figure 4–2 shows the multiplier block architecture. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 4: Embedded Multipliers in Cyclone IV Devices Architecture 4–3 Figure 4–2. Multiplier Block Architecture signa signb aclr clock ena Data A D Q ENA Data Out D Q ENA CLRN CLRN Data B D Q ENA CLRN Input Register Output Register Embedded Multiplier Block Input Registers You can send each multiplier input signal into an input register or directly into the multiplier in 9- or 18-bit sections, depending on the operational mode of the multiplier. Each multiplier input signal can be sent through a register independently of other input signals. For example, you can send the multiplier Data A signal through a register and send the Data B signal directly to the multiplier. The following control signals are available for each input register in the embedded multiplier: ■ clock ■ clock enable ■ asynchronous clear All input and output registers in a single embedded multiplier are fed by the same clock, clock enable, and asynchronous clear signals. Multiplier Stage The multiplier stage of an embedded multiplier block supports 9 × 9 or 18 × 18 multipliers as well as other multipliers between these configurations. Depending on the data width or operational mode of the multiplier, a single embedded multiplier can perform one or two multiplications in parallel. For multiplier information, refer to “Operational Modes” on page 4–4. Each multiplier operand is a unique signed or unsigned number. Two signals, signa and signb, control an input of a multiplier and determine if the value is signed or unsigned. If the signa signal is high, the Data A operand is a signed number. If the signa signal is low, the Data A operand is an unsigned number. Table 4–2 shows the sign of the multiplication results for the various operand sign representations. The results of the multiplication are signed if any one of the operands is a signed value. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 4–4 Chapter 4: Embedded Multipliers in Cyclone IV Devices Operational Modes Table 4–2. Multiplier Sign Representation Data A Data B signa Value Logic Level signb Value Logic Level Result Unsigned Low Unsigned Low Unsigned Unsigned Low Signed High Signed Signed High Unsigned Low Signed Signed High Signed High Signed Each embedded multiplier block has only one signa and one signb signal to control the sign representation of the input data to the block. If the embedded multiplier block has two 9 × 9 multipliers, the Data A input of both multipliers share the same signa signal, and the Data B input of both multipliers share the same signb signal. You can dynamically change the signa and signb signals to modify the sign representation of the input operands at run time. You can send the signa and signb signals through a dedicated input register. The multiplier offers full precision, regardless of the sign representation. 1 When the signa and signb signals are unused, the Quartus II software sets the multiplier to perform unsigned multiplication by default. Output Registers You can register the embedded multiplier output using output registers in either 18- or 36-bit sections, depending on the operational mode of the multiplier. The following control signals are available for each output register in the embedded multiplier: ■ clock ■ clock enable ■ asynchronous clear All input and output registers in a single embedded multiplier are fed by the same clock, clock enable, and asynchronous clear signals. Operational Modes You can use an embedded multiplier block in one of two operational modes, depending on the application needs: 1 ■ One 18-bit × 18-bit multiplier ■ Up to two 9-bit × 9-bit independent multipliers You can also use embedded multipliers of Cyclone IV devices to implement multiplier adder and multiplier accumulator functions, in which the multiplier portion of the function is implemented using embedded multipliers, and the adder or accumulator function is implemented in logic elements (LEs). Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 4: Embedded Multipliers in Cyclone IV Devices Operational Modes 4–5 18-Bit Multipliers You can configure each embedded multiplier to support a single 18 × 18 multiplier for input widths of 10 to 18 bits. Figure 4–3 shows the embedded multiplier configured to support an 18-bit multiplier. Figure 4–3. 18-Bit Multiplier Mode signa signb aclr clock ena Data A [17..0] D Q ENA Data Out [35..0] CLRN D Q ENA CLRN Data B [17..0] D Q ENA CLRN 18 × 18 Multiplier Embedded Multiplier All 18-bit multiplier inputs and results are independently sent through registers. The multiplier inputs can accept signed integers, unsigned integers, or a combination of both. Also, you can dynamically change the signa and signb signals and send these signals through dedicated input registers. 9-Bit Multipliers You can configure each embedded multiplier to support two 9 × 9 independent multipliers for input widths of up to 9 bits. Figure 4–4 shows the embedded multiplier configured to support two 9-bit multipliers. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 4–6 Chapter 4: Embedded Multipliers in Cyclone IV Devices Operational Modes Figure 4–4. 9-Bit Multiplier Mode signa signb aclr clock ena Data A 0 [8..0] D Q ENA Data Out 0 [17..0] CLRN D Q ENA CLRN Data B 0 [8..0] D Q ENA CLRN 9 × 9 Multiplier Data A 1 [8..0] D Q ENA Data Out 1 [17..0] CLRN D Q ENA CLRN Data B 1 [8..0] D Q ENA CLRN 9 × 9 Multiplier Embedded Multiplier All 9-bit multiplier inputs and results are independently sent through registers. The multiplier inputs can accept signed integers, unsigned integers, or a combination of both. Two 9 × 9 multipliers in the same embedded multiplier block share the same signa and signb signal. Therefore, all the Data A inputs feeding the same embedded multiplier must have the same sign representation. Similarly, all the Data B inputs feeding the same embedded multiplier must have the same sign representation. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 4: Embedded Multipliers in Cyclone IV Devices Chapter Revision History 4–7 Chapter Revision History Table 4–3 shows the revision history for this chapter. Table 4–3. Chapter Revision History Date November 2009 © November 2009 Version 1.0 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 1 4–8 Cyclone IV Device Handbook, Volume 1 Chapter 4: Embedded Multipliers in Cyclone IV Devices Chapter Revision History © November 2009 Altera Corporation 5. Clock Networks and PLLs in Cyclone IV Devices CYIV-51005-1.0 This chapter describes the hierarchical clock networks and phase-locked loops (PLLs) with advanced features in Cyclone® IV devices. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. This chapter includes the following sections: ■ “Clock Networks” on page 5–1 ■ “PLLs in Cyclone IV Devices” on page 5–13 ■ “Cyclone IV PLL Hardware Overview” on page 5–15 ■ “Clock Feedback Modes” on page 5–17 ■ “Hardware Features” on page 5–21 ■ “Programmable Bandwidth” on page 5–27 ■ “Phase Shift Implementation” on page 5–27 ■ “PLL Cascading” on page 5–29 ■ “PLL Reconfiguration” on page 5–29 ■ “Spread-Spectrum Clocking” on page 5–36 ■ “PLL Specifications” on page 5–36 Clock Networks Cyclone IV devices provide up to 12 dedicated clock pins (CLK[15..4]) that can drive the global clocks (GCLKs). Cyclone IV devices support four dedicated clock pins on each side of the device except the left side. These clock pins can drive up to 30 GCLKs. f For more information about the number of GCLK networks in each device density, refer to the Cyclone IV FPGA Device Family Overview chapter in volume 1. GCLK Network GCLKs drive throughout the entire device, feeding all device quadrants. All resources in the device (I/O elements, logic array blocks (LABs), dedicated multiplier blocks, and M9K memory blocks) can use GCLKs as clock sources. Use these clock network resources for control signals, such as clock enables and clears fed by an external pin. Internal logic can also drive GCLKs for internally generated GCLKs and asynchronous clears, clock enables, or other control signals with high fan-out. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–2 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks Table 5–1 and Table 5–2 on page 5–4 list the connectivity of the clock sources to the GCLK networks. Table 5–1. GCLK Network Connections for EP4CGX15, EP4CGX22, and EP4CGX30 (Part 1 of 2) GCLK Network Clock Sources GCLK Networks 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CLK4/DIFFCLK_2n — — — — — v — v — v — — — — — — — — — — CLK5/DIFFCLK_2p — — — — — — v v — — — — — — — — — — — — CLK6/DIFFCLK_3n — — — — — — v — v v — — — — — — — — — — CLK7/DIFFCLK_3p — — — — — v — — v — — — — — — — — — — — CLK8/DIFFCLK_5n — — — — — — — — — — v — v — v — — — — — CLK9/DIFFCLK_5p — — — — — — — — — — — v v — — — — — — — CLK10/DIFFCLK_4n — — — — — — — — — — — v — v v — — — — — /REFCLK1n CLK11/DIFFCLK_4p — — — — — — — — — — v — — v — — — — — — /REFCLK1p CLK12/DIFFCLK_7p — — — — — — — — — — — — — — — v — v — v /REFCLK0p CLK13/DIFFCLK_7n — — — — — — — — — — — — — — — — v v — — /REFCLK0n CLK14/DIFFCLK_6p — — — — — — — — — — — — — — — — v — v v CLK15/DIFFCLK_6n — — — — — — — — — — — — — — — v — — v — MPLL1_C0 v — — v — — — — — — — — — — — v — — v — MPLL1_C1 — v — — v — — — — — — — — — — — v — — v MPLL1_C2 v — v — — — — — — — — — — — — v — v — — MPLL1_C3 — v — v — — — — — — — — — — — — v — v — MPLL1_C4 — — v — v — — — — — — — — — — — — v — v MPLL2_C0 v — — v — — — — — — v — — v — — — — — — MPLL2_C1 — v — — v — — — — — — v — — v — — — — — MPLL2_C2 v — v — — — — — — — v — v — — — — — — — MPLL2_C3 — v — v — — — — — — — v — v — — — — — — MPLL2_C4 — — v — v — — — — — — — v — v — — — — — GPLL3_C0 — — — — — v — — v — — — — — — v — — v — GPLL3_C1 — — — — — — v — — v — — — — — — v — — v GPLL3_C2 — — — — — v — v — — — — — — — v — v — — GPLL3_C3 — — — — — — v — v — — — — — — — v — v — GPLL3_C4 — — — — — — — v — v — — — — — — — v — v GPLL4_C0 (1) — — — — — v — — v — v — — v — — — — — — GPLL4_C1 (1) — — — — — — v — — v — v — — v — — — — — GPLL4_C2 (1) — — — — — v — v — — v — v — — — — — — — GPLL4_C3 (1) — — — — — — v — v — — v — v — — — — — — GPLL4_C4 (1) — — — — — — — v — v — — v — v — — — — — DPCLK2 ─ Cyclone IV Device Handbook, Volume 1 ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ ─ v ─ © November 2009 ─ ─ Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks 5–3 Table 5–1. GCLK Network Connections for EP4CGX15, EP4CGX22, and EP4CGX30 (Part 2 of 2) GCLK Network Clock Sources GCLK Networks 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DPCLK3 (2) — — — — — — — — — — — — — — — — — — v — DPCLK4 (2) — — — — — — — — — — — — — — — — — v — — DPCLK5 — — — — — — — — — — — — — — — — — — — v DPCLK6 (2) — — — — — — — — v — — — — — — — — — — — DPCLK7 — — — — — — v — — — — — — — — — — — — — DPCLK8 — — — — — — — — — v — — — — — — — — — — DPCLK9 (2) — — — — — — — v — — — — — — — — — — — — DPCLK10 — — — — — — — — — — — — — — v — — — — — DPCLK11 (2) — — — — — — — — — — — — v — — — — — — — DPCLK12 (2) — — — — — — — — — — — — — v — — — — — — DPCLK13 — — — — — — — — — — — v — — — — — — — — Notes to Table 5–1: (1) GPLL4 is only available in EP4CGX22 and EP4CGX30 devices. (2) This pin applies to EP4CGX22 and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–4 Cyclone IV Device Handbook, Volume 1 Table 5–2. GCLK Network Connections for EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 Devices (Part 1 of 3) GCLK Network Clock Sources GCLK Networks 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 CLK4/DIFFCLK_2n — — — — — — — — — — — — v — v — v — — — — — — — — — — — — — CLK5/DIFFCLK_2p — — — — — — — — — — — — — v v — — v — — — — — — — — — — — — CLK6/DIFFCLK_3n — — — — — — — — — — — — — v — v v — — — — — — — — — — — — — CLK7/DIFFCLK_3p — — — — — — — — — — — — v — — v — v — — — — — — — — — — — — CLK8/DIFFCLK_5n — — — — — — — — — — — — — — — — — — v — v — v — — — — — — — CLK9/DIFFCLK_5p — — — — — — — — — — — — — — — — — — — v v — — v — — — — — — CLK10/DIFFCLK_4n — — — — — — — — — — — — — — — — — — — v — v v /REFCLK3n — — — — — — CLK11/DIFFCLK_4p — — — — — — — — — — — — — — — — — — v — — v — v — — — — — — /REFCLK3p CLK12/DIFFCLK_7p — — — — — — — — — — — — — — — — — — — — — — — — v — v — v — /REFCLK2p CLK13/DIFFCLK_7n — — — — — — — — — — — — — — — — — — — — — — — — — v v — — v /REFCLK2n CLK15/DIFFCLK_6n — — — — — — — — — — — — — — — — — — — — — — — — v — — v — v © November 2009 Altera Corporation GPLL1_C0 v — — v — v — — — — — — — — — — — — — — — — — — v — — v — v GPLL1_C1 — v — — v — — — — — — — — — — — — — — — — — — — — v — — v — GPLL1_C2 v — v — — — — — — — — — — — — — — — — — — — — — v — v — — — GPLL1_C3 — v — v — — — — — — — — — — — — — — — — — — — — — v — v — — GPLL1_C4 — — v — v v — — — — — — — — — — — — — — — — — — — — v — v v GPLL2_C0 — — — — — — v — — v — v — — — — — — v — — v — v — — — — — — GPLL2_C1 — — — — — — — v — — v — — — — — — — — v — — v — — — — — — — GPLL2_C2 — — — — — — v — v — — — — — — — — — v — v — — — — — — — — — GPLL2_C3 — — — — — — — v — v — — — — — — — — — v — v — — — — — — — — GPLL2_C4 — — — — — — — — v — v v — — — — — — — — v — v v — — — — — — Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks CLK14/DIFFCLK_6p — — — — — — — — — — — — — — — — — — — — — — — — — v — v v — GCLK Network Clock Sources GCLK Networks 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Altera Corporation — — — — — — — — — — — — v — — v — v — — — — — — v — — v — v GPLL3_C1 — — — — — — — — — — — — — v — — v — — — — — — — — v — — v — GPLL3_C2 — — — — — — — — — — — — v — v — — — — — — — — — v — v — — — GPLL3_C3 — — — — — — — — — — — — — v — v — — — — — — — — — v — v — — GPLL3_C4 — — — — — — — — — — — — — — v — v v — — — — — — — — v — v v GPLL4_C0 — — — — — — — — — — — — v — — v — v v — — v — v — — — — — — GPLL4_C1 — — — — — — — — — — — — — v — — v — — v — — v — — — — — — — GPLL4_C2 — — — — — — — — — — — — v — v — — — v — v — — — — — — — — — GPLL4_C3 — — — — — — — — — — — — — v — v — — — v — v — — — — — — — — GPLL4_C4 — — — — — — — — — — — — — — v — v v — — v — v v — — — — — — MPLL5_C0 v — — v — v — — — — — — — — — — — — — — — — — — — — — — — — MPLL5_C1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL5_C2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL5_C3 — v — v — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL5_C4 — — v — v v — — — — — — — — — — — — — — — — — — — — — — — — MPLL6_C0 — v — — v — — — — — — — — — — — — — — — — — — — — — — — — — MPLL6_C1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL6_C2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL6_C3 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL6_C4 v — v — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL7_C0 — — — — — — — v — — v — — — — — — — — — — — — — — — — — — — MPLL7_C1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL7_C2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL7_C3 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL7_C4 — — — — — — v — v — — — — — — — — — — — — — — — — — — — — — 5–5 Cyclone IV Device Handbook, Volume 1 GPLL3_C0 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks © November 2009 Table 5–2. GCLK Network Connections for EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 Devices (Part 2 of 3) GCLK Network Clock Sources 5–6 Cyclone IV Device Handbook, Volume 1 Table 5–2. GCLK Network Connections for EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 Devices (Part 3 of 3) GCLK Networks 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Altera Corporation — — — — — — v — — v — v — — — — — — — — — — — — — — — — — — MPLL8_C1 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL8_C2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MPLL8_C3 — — — — — — — v — v — — — — — — — — — — — — — — — — — — — — MPLL8_C4 — — — — — — — — v — v v — — — — — — — — — — — — — — — — — — DPCLK0 — — — — — — — — — — — — — — — — — — — — — — — — — v — — — — DPCLK1 — — — — — — — — — — — — — — — — — — — — — — — — — — — v — — DPCLK2 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — v DPCLK3 — — — — — — — — — — — — — — — — — — — — — — — — v — — — — — DPCLK4 — — — — — — — — — — — — — — — — — — — — — — — — — — v — — — DPCLK5 — — — — — — — — — — — — — — — — — — — — — — — — — — — — v — DPCLK6 — — — — — — — — — — — — — — — — — v — — — — — — — — — — — — DPCLK7 — — — — — — — — — — — — — — — v — — — — — — — — — — — — — — DPCLK8 — — — — — — — — — — — — — v — — — — — — — — — — — — — — — — DPCLK9 — — — — — — — — — — — — — — — — v — — — — — — — — — — — — — DPCLK10 — — — — — — — — — — — — — — v — — — — — — — — — — — — — — — DPCLK11 — — — — — — — — — — — — v — — — — — — — — — — — — — — — — — DPCLK12 — — — — — — — — — — — — — — — — — — — — — — v — — — — — — — DPCLK13 — — — — — — — — — — — — — — — — — — — — v — — — — — — — — — DPCLK14 — — — — — — — — — — — — — — — — — — v — — — — — — — — — — — DPCLK15 — — — — — — — — — — — — — — — — — — — — — — — v — — — — — — DPCLK16 — — — — — — — — — — — — — — — — — — — — — v — — — — — — — — DPCLK17 — — — — — — — — — — — — — — — — — — — v — — — — — — — — — — Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks © November 2009 MPLL8_C0 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks 5–7 If you do not use dedicated clock pins to feed the GCLKs, you can use them as general-purpose input pins to feed the logic array. However, when using them as general-purpose input pins, they do not have support for an I/O register and must use LE-based registers in place of an I/O register. Clock Control Block The clock control block drives GCLKs. Clock control blocks are located on each side of the device, close to the dedicated clock input pins. GCLKs are optimized for minimum clock skew and delay. Table 5–3 lists the sources that can feed the clock control block, that in turn feeds the GCLKs. Table 5–3. Clock Control Block Inputs Input Description Dedicated clock inputs Dedicated clock input pins can drive clocks or global signals, such as synchronous and asynchronous clears, presets, or clock enables onto given GCLKs. Dual -purpose clock (DPCLK) I/O input DPCLK I/O pins are bidirectional dual function pins that are used for high fan-out control signals, such as protocol signals, TRDY and IRDY signals for PCI, via the GCLK. Clock control blocks that have inputs driven by dual -purpose clock I/O pins are not able to drive PLL inputs. PLL outputs PLL counter outputs can drive the GCLK. Internal logic You can drive the GCLK through logic array routing to enable internal logic elements (LEs) to drive a high fan-out, low-skew signal path. Clock control blocks that have inputs driven by internal logic are not able to drive PLL inputs. In Cyclone IV devices, dedicated clock input pins, PLL counter outputs, dual-purpose clock I/O inputs, and internal logic can all feed the clock control block for each GCLK. The output from the clock control block in turn feeds the corresponding GCLK. The GCLK can drive the PLL input if the clock control block inputs are outputs of another PLL or dedicated clock input pins. There are five or six clock control blocks on each side of the device periphery—depending on device density; providing up to 30 clock control blocks in each Cyclone IV device. For the clock control block locations, refer to Figure 5–2 on page 5–9 and Figure 5–3 on page 5–10. 1 The clock control blocks on the left side of the Cyclone IV device do not support any clock inputs. The control block has two functions: © November 2009 ■ Dynamic GCLK clock source selection (not applicable for DPCLK and internal logic input) ■ GCLK network power down (dynamic enable and disable) Altera Corporation Cyclone IV Device Handbook, Volume 1 5–8 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks Figure 5–1 shows the clock control block. Figure 5–1. Clock Control Block Clock Control Block Internal Logic Static Clock Select (3) C0 C1 CLK[n + 3] CLK[n + 2] CLK[n + 1] CLK[n] inclk1 inclk0 fIN PLL Global Clock Enable/ Disable DPCLK Static Clock Select (3) C2 C3 C4 CLKSWITCH (1) (4) CLKSELECT[1..0] (2) Internal Logic (5) C0 C1 inclk1 inclk0 fIN PLL C2 C3 C4 CLKSWITCH (1) Notes to Figure 5–1: (1) The clkswitch signal can either be set through the configuration file or dynamically set when using the manual PLL switchover feature. The output of the multiplexer is the input clock (fIN) for the PLL. (2) The clkselect[1..0] signals are fed by internal logic and are used to dynamically select the clock source for the GCLK when the device is in user mode. (3) The static clock select signals are set in the configuration file. Therefore, dynamic control when the device is in user mode is not feasible. (4) Two out of four PLL clock outputs are selected from adjacent PLLs to drive into the clock control block. (5) You can use internal logic to enable or disable the GCLK in user mode. Each PLL generates five clock outputs through the c[4..0] counters. Two of these clocks can drive the GCLK through a clock control block, as shown in Figure 5–1. f For more information about how to use the clock control block in the Quartus® II software, refer to the ALTCLKCTRL Megafunction User Guide. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks 5–9 GCLK Network Clock Source Generation Figure 5–2 and Figure 5–3 show the Cyclone IV PLLs, clock inputs, and clock control block location for different Cyclone IV device densities. Figure 5–2. Clock Networks and Clock Control Block Locations in EP4CGX15, EP4CGX22, and EP4CGX30 Devices DPCLK[13..12] (3) DPCLK[11..10] (3) CLK[11..8] 2 MPLL 2 2 4 4 GPLL (2) 4 4 5 5 Clock Control Block (1) 4 5 5 GCLK[19..0] 20 Clock Control Block (1) HSSI DPCLK[9..8] (3) 2 20 Clock Control Block (1) 20 20 4 GCLK[19..0] 2 CLK[7..4] DPCLK[7..6] (3) 4 5 5 Clock Control Block (1) 5 MPLL 1 5 4 4 2 4 GPLL 3 2 CLK[15..12] DPCLK[3..2] (3) DPCLK[5..4] (3) Notes to Figure 5–2: (1) There are five clock control blocks on each side. (2) GPLL4 is only available in EP4CGX22 and EP4CGX30 devices. (3) The EP4CGX15 device has two DPCLK pins on each side of the device: DPCLK2 and DPCLK5 on bottom side, DPCLK7 and DPCLK8 on the right side, DPCLK10 and DPCLK13 on the top side of device. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–10 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks Figure 5–3. Clock Networks and Clock Control Block Locations in EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 Devices DPCLK[17..15] DPCLK[14..12] CLK[19..16] (2) CLK[11..8] 3 4 MPLL 8 GPLL 2 4 GPLL 4 4 5 HSSI 3 4 5 Clock Control Block (1) 4 3 5 5 GCLK[29..0] MPLL 7 Clock Control Block (1) 2 MPLL 6 30 30 Clock Control Block (1) 30 Clock Control Block (1) 2 3 30 4 3 GCLK[29..0] DPCLK[11..9] CLK[7..4] DPCLK[8..6] 4 HSSI 5 3 5 Clock Control Block (1) 5 MPLL 5 GPLL 1 5 4 4 4 3 CLK[23..20] (2) 4 GPLL 3 3 CLK[15..12] DPCLK[2..0] DPCLK[5..3] Notes to Figure 5–3: (1) There are 6 clock control blocks on the top, right and bottom sides of the device and 12 clock control blocks on the left side of the device. (2) CLK[19..16] and CLK[23..20] can only drive the general -purpose PLLs (GPLLs) and multi-purpose PLLs (MPLLs) on the left side of the device. These clock pins do not have access to the clock control blocks and GCLK networks. The inputs to the clock control blocks on each side must be chosen from among the following clock sources: ■ Four clock input pins ■ Ten PLL counter outputs (five from each adjacent PLLs) ■ Two, four, or six DPCLK pins from the top, bottom, and right sides of the device ■ Five signals from internal logic Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks 5–11 From the clock sources listed above, only two clock input pins, two out of four PLL clock outputs (two clock outputs from either adjacent PLLs), one DPCLK pin, and one source from internal logic can drive into any given clock control block, as shown in Figure 5–1 on page 5–8. Out of these six inputs to any clock control block, the two clock input pins and two PLL outputs are dynamically selected to feed a GCLK. The clock control block supports static selection of the signal from internal logic. Figure 5–4 shows a simplified version of the five clock control blocks on each side of the Cyclone IV devices periphery. Figure 5–4. Clock Control Blocks on Each Side of Cyclone IV Devices Clock Input Pins PLL Outputs DPCLK (1) Internal Logic 4 10 2, 4, or 6 Clock Control Block 5 or 6 (2) GCLK 5 Five or six clock control blocks on each side of the device Notes to Figure 5–4: (1) The EP4CGX15 device has two DPCLK pins; the EP4CGX22 and EP4CGX30 devices have four DPCLK pins; the EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices have six DPCLK pins. (2) Each clock control block in the EP4CGX15, EP4CGX22, and EP4CGX30 devices can drive five GCLK networks while each clock control block in the EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices can drive six GCLK networks. GCLK Network Power Down You can disable a Cyclone IV device’s GCLK (power down) using both static and dynamic approaches. In the static approach, configuration bits are set in the configuration file generated by the Quartus II software, that automatically disables unused GCLKs. The dynamic clock enable or disable feature allows internal logic to control clock enable or disable of the GCLKs in Cyclone IV devices. When a clock network is disabled, all the logic fed by the clock network is in an off-state, thereby reducing the overall power consumption of the device. This function is independent of the PLL and is applied directly on the clock network, as shown in Figure 5–1 on page 5–8. You can set the input clock sources and the clkena signals for the GCLK multiplexers through the Quartus II software using the ALTCLKCTRL megafunction. f © November 2009 For more information, refer to the ALTCLKCTRL Megafunction User Guide. Altera Corporation Cyclone IV Device Handbook, Volume 1 5–12 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Networks clkena Signals Cyclone IV devices support clkena signals at the GCLK network level. This allows you to gate-off the clock even when a PLL is used. Upon re-enabling the output clock, the PLL does not need a resynchronization or re-lock period because the circuit gates off the clock at the clock network level. In addition, the PLL can remain locked independent of the clkena signals because the loop-related counters are not affected. Figure 5–5 shows how to implement the clkena signal. Figure 5–5. clkena Implementation clkena D Q clkena_out clkin clk_out 1 The clkena circuitry controlling the output C0 of the PLL to an output pin is implemented with two registers instead of a single register, as shown in Figure 5–5. Figure 5–6 shows the waveform example for a clock output enable. The clkena signal is sampled on the falling edge of the clock (clkin). 1 This feature is useful for applications that require low power or sleep mode. Figure 5–6. clkena Implementation: Output Enable clkin clkena clk_out The clkena signal can also disable clock outputs if the system is not tolerant to frequency overshoot during PLL resynchronization. Altera recommends using the clkena signals when switching the clock source to the PLLs or the GCLK. The recommended sequence is: 1. Disable the primary output clock by de-asserting the clkena signal. 2. Switch to the secondary clock using the dynamic select signals of the clock control block. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLLs in Cyclone IV Devices 5–13 3. Allow some clock cycles of the secondary clock to pass before reasserting the clkena signal. The exact number of clock cycles you must wait before enabling the secondary clock is design-dependent. You can build custom logic to ensure glitch-free transition when switching between different clock sources. PLLs in Cyclone IV Devices Cyclone IV devices offer two variations of PLLs: the GPLLs and the MPLLs. The GPLLs are used for general-purpose applications in the FPGA fabric and periphery such as external memory interfaces. The MPLLs are used for clocking the transceiver blocks. When the MPLLs are not used for transceiver clocking, they can be used for general-purpose clocking. f For more details about the MPLLs used for transceiver clocking, refer to the Cyclone IV Transceivers chapter in volume 2. Cyclone IV devices contain up to eight GPLLs and MPLLs that provide robust clock management and synthesis for device clock management, external system clock management, and high-speed I/O interfaces. f For more information about the number of GPLLs and MPLLs in each device density, refer to the Cyclone IV Device Family Overview chapter in volume 1. Table 5–4 lists the features available in Cyclone IV PLLs. Table 5–4. Cyclone IV PLL Features (Part 1 of 2) Availability General-purpose PLLs Features GPLL1 (1) GPLL2 (1) GPLL3 (2) Multi-purpose PLLs GPLL4 MPLL1 MPLL2 MPLL5 MPLL6 MPLL7 MPLL8 (3) (4) (4) (1) (1) (1) (1) C (output counters) 5 M, N, C counter sizes 1 to 512 (5) Dedicated clock outputs 1 single-ended or 1 differential pair Clock input pins 12 single-ended or 6 differential pairs(6) and 4 differential pairs(7) v (8) Spread-spectrum input clock tracking PLL cascading Through GCLK Source-Synchronous Mode v v v v v v v — — v No Compensation Mode v v v v v v v v v v Normal Mode v v v v v v v — — v Zero Delay Buffer Mode v v v v v v v — — v Deterministic Latency Compensation Mode v v — — v v v v v v Phase shift resolution (9) Programmable duty cycle © November 2009 Altera Corporation Down to 96 ps increments Down to 78 ps increments (10) v Cyclone IV Device Handbook, Volume 1 5–14 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLLs in Cyclone IV Devices Table 5–4. Cyclone IV PLL Features (Part 2 of 2) Availability General-purpose PLLs Features GPLL1 (1) GPLL2 (1) GPLL3 (2) Multi-purpose PLLs GPLL4 MPLL1 MPLL2 MPLL5 MPLL6 MPLL7 MPLL8 (3) (4) (4) (1) (1) (1) (1) Output counter cascading v Input clock switchover v User mode reconfiguration v Loss of lock detection v PLL drives TX Serial Clock, TX Load Enable, and TX Parallel Clock v v VCO output drives RX clock data recovery (CDR) clock PLL drives FREF for ppm detect v — — v — v v — — v Notes to Table 5–4: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) This is only applicable to EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices. This is applicable to all Cyclone IV devices. This is applicable to all Cyclone IV devices except EP4CGX15 devices. This is only applicable to EP4CGX15, EP4CGX22, and EP4CGX30 devices. C counters range from 1 through 512 if the output clock uses a 50% duty cycle. For any output clocks using a non-50% duty cycle, the post -scale counters range from 1 through 256. These clock pins can access the GCLK networks. These clock pins are only available in EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices and cannot access the GCLK networks. Only applicable if the input clock jitter is in the input jitter tolerance specifications. The smallest phase shift is determined by the voltage-controlled oscillator (VCO) period divided by eight. For degree increments, Cyclone IV devices can shift all output frequencies in increments of at least 45°. Smaller degree increments are possible depending on the frequency and divide parameters. Applicable only when MPLLs are used for transceiver clocking. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Cyclone IV PLL Hardware Overview 5–15 Cyclone IV PLL Hardware Overview This section gives a hardware overview of the Cyclone IV PLL. Figure 5–7 shows a simplified block diagram of the major components of the PLL of Cyclone IV devices. Figure 5–7. Cyclone IV PLL Block Diagram (Note 1) To RX CDR clocks (MPLLs only) lock FREF for ppm detect (MPLLs only) LOCK circuit ÷2, ÷4 ÷C0 8 Clock inputs from pins 4 (2) inclk0 Clock Switchover inclk1 Block GCLK (4) ÷n clkswitch clkbad0 clkbad1 activeclock PFD CP LF VCO 8 ÷2 (3) GCLKs (5) ÷C1 8 ÷C2 VCO Range Detector ÷C3 VCOOVRR ÷C4 VCOUNDR TX serial clock (MPLLs only) (6) TX load enable (MPLLs only) (7) TX parallel clock (MPLLs only) (8) Deterministic Latency compensation (MPLLs only) pfdena External clock output PLL output mux ÷M no compensation; ZDB mode source-synchronous; normal mode GCLK networks Notes to Figure 5–7: (1) Each clock source can come from any of the four clock pins located on the same side of the device as the PLL. (2) There are additional 4 pairs of dedicated differential clock inputs in EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices that can only drive GPLLs and MPLLs on the left side of the device. CLK[19..16] can access GPLL2, MPLL6, MPLL7, and MPLL8 while CLK[23..20] can access GPLL1, MPLL5, MPLL6, and MPLL7. For the location of these clock input pins, refer to Figure 5–3 on page 5–10 . (3) This is the VCO post -scale counter K. (4) This input port is fed by a pin-driven dedicated GCLK, or through a clock control block if the clock control block is fed by an output from another PLL or a pin-driven dedicated GCLK. An internally generated global signal cannot drive the PLL. (5) For the GPLL and MPLL counter outputs connectivity to the GCLKs, refer to Table 5–1 on page 5–2 and Table 5–2 on page 5–4. (6) Only the CI output counter can drive the TX serial clock. (7) Only the C2 output counter can drive the TX load enable. (8) Only the C3 output counter can drive the TX parallel clock. 1 The VCO post-scale counter K is used to divide the supported VCO range by two. The VCO frequency reported by the Quartus II software in the PLL summary section of the compilation report takes into consideration the VCO post-scale counter value. Therefore, if the VCO post-scale counter has a value of 2, the frequency reported is lower than the fVCO specification specified in the Cyclone IV Device Data Sheet chapter in volume 3. External Clock Outputs Each PLL of Cyclone IV devices supports one single-ended clock output or one differential clock output. Only the C0 output counter can feed the dedicated external clock outputs, as shown in Figure 5–8, without going through the GCLK. Other output counters can feed other I/O pins through the GCLK. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–16 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Cyclone IV PLL Hardware Overview Figure 5–8 shows the external clock outputs for PLLs. Figure 5–8. External Clock Outputs for PLLs C0 C1 C2 PLL# C3 C4 clkena 0 (1) clkena 1 (1) PLL#_CLKOUTp (2) PLL#_CLKOUTn (2) Notes to Figure 5–8: (1) These external clock enable signals are available only when using the ALTCLKCTRL megafunction. (2) PLL#_CLKOUTp and PLL#_CLKOUTn pins are dual-purpose I/O pins that you can use as one single-ended clock output or one differential clock output. When using both pins as single-ended I/Os, one of them can be the clock output while the other pin is configured as a regular user I/O. Each pin of a differential output pair is 180° out of phase. The Quartus II software places the NOT gate in your design into the I/O element to implement 180° phase with respect to the other pin in the pair. The clock output pin pairs support the same I/O standards as standard output pins. f To determine which I/O standards are supported by the PLL clock input and output pins, refer to the Cyclone IV Device I/O Features chapter in volume 1. Cyclone IV PLLs can drive out to any regular I/O pin through the GCLK. You can also use the external clock output pins as general-purpose I/O pins if external PLL clocking is not required. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Feedback Modes 5–17 Clock Feedback Modes Cyclone IV PLLs support up to five different clock feedback modes. Each mode allows clock multiplication and division, phase shifting, and programmable duty cycle. Refer to Table 5–4 on page 5–13 for the feedback modes supported by the various PLLs. 1 Input and output delays are fully compensated by the PLL only if you are using the dedicated clock input pins associated with a given PLL as the clock sources. When driving the PLL using the GCLK network, the input and output delays may not be fully compensated in the Quartus II software. Source-Synchronous Mode If the data and clock arrive at the same time at the input pins, the phase relationship between the data and clock remains the same at the data and clock ports of any I/O element input register. Figure 5–9 shows an example waveform of the data and clock in this mode. Use this mode for source-synchronous data transfers. Data and clock signals at the I/O element experience similar buffer delays as long as the same I/O standard is used. Figure 5–9. Phase Relationship Between Data and Clock in Source-Synchronous Mode Data pin PLL reference clock at input pin Data at register Clock at register Source-synchronous mode compensates for delay of the clock network used, including any difference in the delay between the following two paths: 1 © November 2009 ■ Data pin to I/O element register input ■ Clock input pin to the PLL phase frequency detector (PFD) input Set the input pin to the register delay chain in the I/O element to zero in the Quartus II software for all data pins clocked by a source-synchronous mode PLL. Also, all data pins must use the PLL COMPENSATED logic option in the Quartus II software. Altera Corporation Cyclone IV Device Handbook, Volume 1 5–18 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Feedback Modes No Compensation Mode In no compensation mode, the PLL does not compensate for any clock networks. This provides better jitter performance because clock feedback into the PFD does not pass through as much circuitry. Both the PLL internal and external clock outputs are phase shifted with respect to the PLL clock input. Figure 5–10 shows a waveform example of the phase relationship of the PLL clock in this mode. Figure 5–10. Phase Relationship Between PLL Clocks in No Compensation Mode Phase Aligned PLL Reference Clock at the Input Pin PLL Clock at the Register Clock Port (1), (2) External PLL Clock Outputs (2) Notes to Figure 5–10: (1) Internal clocks fed by the PLL are phase -aligned to each other. (2) The PLL clock outputs can lead or lag the PLL input clocks. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Feedback Modes 5–19 Normal Mode An internal clock in normal mode is phase-aligned to the input clock pin. The external clock output pin has a phase delay relative to the clock input pin if connected in this mode. The Quartus II software timing analyzer reports any phase difference between the two. In normal mode, the PLL fully compensates the delay introduced by the GCLK network. Figure 5–11 shows a waveform example of the phase relationship of the PLL clocks in this mode. Figure 5–11. Phase Relationship Between PLL Clocks in Normal Mode Phase Aligned PLL Reference Clock at the Input pin PLL Clock at the Register Clock Port External PLL Clock Outputs (1) Note to Figure 5–11: (1) The external clock output can lead or lag the PLL internal clock signals. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–20 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Clock Feedback Modes Zero Delay Buffer Mode In zero delay buffer (ZDB) mode, the external clock output pin is phase-aligned with the clock input pin for zero delay through the device. When using this mode, use the same I/O standard on the input clock and output clocks to guarantee clock alignment at the input and output pins. Figure 5–12 shows an example waveform of the phase relationship of the PLL clocks in ZDB mode. Figure 5–12. Phase Relationship Between PLL Clocks in ZDB Mode Phase Aligned PLL Reference Clock at the Input Pin PLL Clock at the Register Clock Port External PLL Clock Output at the Output Pin Deterministic Latency Compensation Mode The deterministic latency mode compensates for the delay of the MPLLs through the clock network and serializer in Common Public Radio Interface (CPRI) applications. In this mode, the PLL PFD feedback path compensates the latency uncertainty in Tx dataout and Tx clkout paths relative to the reference clock. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features 5–21 Hardware Features Cyclone IV PLLs support several features for general-purpose clock management. This section discusses clock multiplication and division implementation, phase shifting implementations, and programmable duty cycles. Clock Multiplication and Division Each Cyclone IV PLL provides clock synthesis for PLL output ports using M/(N*post-scale counter) scaling factors. The input clock is divided by a pre-scale factor, N, and is then multiplied by the M feedback factor. The control loop drives the VCO to match fIN (M/N). Each output port has a unique post-scale counter that divides down the high-frequency VCO. For multiple PLL outputs with different frequencies, the VCO value is the least common multiple of the output frequencies that meets its frequency specifications. For example, if output frequencies required from one PLL are 33 and 66 MHz, the Quartus II software sets the VCO to 660 MHz (the least common multiple of 33 and 66 MHz in the VCO range). Then, the post-scale counters scale down the VCO frequency for each output port. There is one pre-scale counter, N, and one multiply counter, M, per PLL, with a range of 1 to 512 for both M and N. The N counter does not use duty cycle control because the purpose of this counter is only to calculate frequency division. There are five generic post-scale counters per PLL that can feed GCLKs or external clock outputs. These post-scale counters range from 1 to 512 with a 50% duty cycle setting. The post-scale counters range from 1 to 256 with any non-50% duty cycle setting. The sum of the high/low count values chosen for a design selects the divide value for a given counter. The Quartus II software automatically chooses the appropriate scaling factors according to the input frequency, multiplication, and division values entered into the ALTPLL megafunction. 1 © November 2009 Phase alignment between output counters are determined using the tPLL_PSERR specification. Altera Corporation Cyclone IV Device Handbook, Volume 1 5–22 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features Post-Scale Counter Cascading PLLs of Cyclone IV devices support post-scale counter cascading to create counters larger than 512. This is implemented by feeding the output of one C counter into the input of the next C counter, as shown in Figure 5–13. Figure 5–13. Counter Cascading VCO Output VCO Output VCO Output C0 C1 C2 VCO Output C3 VCO Output C4 VCO Output When cascading counters to implement a larger division of the high-frequency VCO clock, the cascaded counters behave as one counter with the product of the individual counter settings. For example, if C0 = 4 and C1 = 2, the cascaded value is C0 × C1 = 8. 1 Post-scale counter cascading is automatically set by the Quartus II software in the configuration file. Post-scale counter cascading cannot be performed using the PLL reconfiguration. Programmable Duty Cycle The programmable duty cycle allows PLLs to generate clock outputs with a variable duty cycle. This feature is supported on the PLL post-scale counters. You can achieve the duty cycle setting by a low and high time count setting for the post-scale counters. The Quartus II software uses the frequency input and the required multiply or divide rate to determine the duty cycle choices. The post-scale counter value determines the precision of the duty cycle. The precision is defined by 50% divided by the post-scale counter value. For example, if the C0 counter is 10, steps of 5% are possible for duty cycle choices between 5 to 90%. Combining the programmable duty cycle with programmable phase shift allows the generation of precise non-overlapping clocks. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features 5–23 PLL Control Signals You can use the pfdena, areset, and locked signals to observe and control the PLL operation and resynchronization. f For more information about the PLL control signals, refer to the ALTPLL Megafunction User Guide. Clock Switchover The clock switchover feature allows the PLL to switch between two reference input clocks. Use this feature for clock redundancy or for a dual-clock domain application, such as a system that turns on the redundant clock if the previous clock stops running. Your design can automatically perform clock switchover when the clock is no longer toggling, or based on the user control signal, clkswitch. Automatic Clock Switchover PLLs of Cyclone IV devices support a fully configurable clock switchover capability. When the current reference clock is not present, the clock-sense block automatically switches to the backup clock for PLL reference. The clock switchover circuit also sends out three status signals—clkbad[0], clkbad[1], and activeclock—from the PLL to implement a custom switchover circuit. You can select a clock source at the backup clock by connecting it to the inclk1 port of the PLL in your design. Figure 5–14 shows the block diagram of the switchover circuit built into the PLL. Figure 5–14. Automatic Clock Switchover Circuit clkbad0 clkbad1 Activeclock Switchover State Machine Clock Sense clksw clkswitch (provides manua switchover suppo inclk0 n Counter inclk1 muxout PFD refclk fbclk © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–24 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features There are two ways to use the clock switchover feature: ■ Use the switchover circuitry for switching from inclk0 to inclk1 running at the same frequency. For example, in applications that require a redundant clock with the same frequency as the reference clock, the switchover state machine generates a signal that controls the multiplexer select input shown in Figure 5–14. In this case, inclk1 becomes the reference clock for the PLL. This automatic switchover can switch back and forth between the inclk0 and inclk1 clocks any number of times, when one of the two clocks fails and the other clock is available ■ Use the clkswitch input for user- or system-controlled switch conditions. This is possible for same-frequency switchover or to switch between inputs of different frequencies. For example, if inclk0 is 66 MHz and inclk1 is 200 MHz, you must control the switchover because the automatic clock-sense circuitry cannot monitor primary and secondary clock frequencies with a frequency difference of more than 20%. This feature is useful when clock sources can originate from multiple cards on the backplane, requiring a system-controlled switchover between frequencies of operation. Choose the secondary clock frequency so the VCO operates in the recommended frequency range. Also, set the M, N, and C counters accordingly to keep the VCO operating frequency in the recommended range Figure 5–15 shows a waveform example of the switchover feature when using automatic loss of clock detection. Here, the inclk0 signal remains low. After the inclk0 signal remains low for approximately two clock cycles, the clock-sense circuitry drives the clkbad[0] signal high. Also, because the reference clock signal is not toggling, the switchover state machine controls the multiplexer through the clksw signal to switch to inclk1. Figure 5–15. Automatic Switchover Upon Clock Loss Detection (Note 1) inclk0 inclk1 (1) muxout clkbad0 clkbad1 activeclock Note to Figure 5–15: (1) Switchover is enabled on the falling edge of inclk0 or inclk1, depending on which clock is available. In this figure, switchover is enabled on the falling edge of inclk1. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features 5–25 Manual Override If you are using the automatic switchover, you must switch input clocks with the manual override feature with the clkswitch input. Figure 5–16 shows an example of a waveform illustrating the switchover feature when controlled by clkswitch. In this case, both clock sources are functional and inclk0 is selected as the reference clock. A low-to-high transition of the clkswitch signal starts the switchover sequence. The clkswitch signal must be high for at least three clock cycles (at least three of the longer clock period if inclk0 and inclk1 have different frequencies). On the falling edge of inclk0, the reference clock of the counter, muxout, is gated off to prevent any clock glitching. On the falling edge of inclk1, the reference clock multiplexer switches from inclk0 to inclk1 as the PLL reference. On the falling edge of inclk1, the reference clock multiplexer switches from inclk0 to inclk1 as the PLL reference, and the activeclock signal changes to indicate which clock is currently feeding the PLL. In this mode, the activeclock signal mirrors the clkswitch signal. As both blocks are still functional during the manual switch, neither clkbad signals go high. Because the switchover circuit is positive edge-sensitive, the falling edge of the clkswitch signal does not cause the circuit to switch back from inclk1 to inclk0. When the clkswitch signal goes high again, the process repeats. The clkswitch signal and the automatic switch only works depending on the availability of the clock that is switched to. If the clock is unavailable, the state machine waits until the clock is available. Figure 5–16. Clock Switchover Using the clkswitch Control (1) inclk0 inclk1 muxout clkswitch activeclock clkbad0 clkbad1 Note to Figure 5–16: (1) Both inclk0 and inclk1 must be running when the clkswitch signal goes high to start a manual clock switchover event. Manual Clock Switchover PLLs of Cyclone IV devices support manual switchover, in which the clkswitch signal controls whether inclk0 or inclk1 is the input clock to the PLL. The characteristics of a manual switchover is similar to the manual override feature in an automatic clock switchover, in which the switchover circuit is edge-sensitive. When the clkswitch signal goes high, the switchover sequence starts. The falling edge of the clkswitch signal does not cause the circuit to switch back to the previous input clock. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–26 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Hardware Features f For more information about PLL software support in the Quartus II software, refer to the ALTPLL Megafunction User Guide. Guidelines Use the following guidelines to design with clock switchover in PLLs: 1 ■ Clock loss detection and automatic clock switchover requires that the inclk0 and inclk1 frequencies be within 20% of each other. Failing to meet this requirement causes the clkbad[0] and clkbad[1] signals to function improperly. ■ When using manual clock switchover, the difference between inclk0 and inclk1 can be more than 20%. However, differences between the two clock sources (frequency, phase, or both) can cause the PLL to lose lock. Resetting the PLL ensures that the correct phase relationships are maintained between the input and output clocks. Both inclk0 and inclk1 must be running when the clkswitch signal goes high to start the manual clock switchover event. Failing to meet this requirement causes the clock switchover to malfunction. ■ Applications that require a clock switchover feature and a small frequency drift must use a low-bandwidth PLL. When referencing input clock changes, the low-bandwidth PLL reacts slower than a high-bandwidth PLL. When the switchover happens, the low-bandwidth PLL propagates the stopping of the clock to the output slower than the high-bandwidth PLL. The low-bandwidth PLL filters out jitter on the reference clock. However, you must be aware that the low-bandwidth PLL also increases lock time. ■ After a switchover occurs, there may be a finite resynchronization period for the PLL to lock onto a new clock. The exact amount of time it takes for the PLL to re-lock is dependent on the PLL configuration. ■ If the phase relationship between the input clock to the PLL and output clock from the PLL is important in your design, assert areset for 10 ns after performing a clock switchover. Wait for the locked signal (or gated lock) to go high before re-enabling the output clocks from the PLL. ■ Figure 5–17 shows how the VCO frequency gradually decreases when the primary clock is lost and then increases as the VCO locks on to the secondary clock. After the VCO locks on to the secondary clock, some overshoot can occur (an over-frequency condition) in the VCO frequency. Figure 5–17. VCO Switchover Operating Frequency Primary Clock Stops Running Frequency Overshoo Switchover Occurs VCO Tracks Secondary Cl Fvco Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Programmable Bandwidth ■ 5–27 Disable the system during switchover if the system is not tolerant to frequency variations during the PLL resynchronization period. You can use the clkbad[0] and clkbad[1] status signals to turn off the PFD (pfdena = 0) so the VCO maintains its last frequency. You can also use the switchover state machine to switch over to the secondary clock. Upon enabling the PFD, output clock enable signals (clkena) can disable clock outputs during the switchover and resynchronization period. After the lock indication is stable, the system can re-enable the output clock or clocks. Programmable Bandwidth The PLL bandwidth is the measure of the PLL’s ability to track the input clock and its associated jitter. PLLs of Cyclone IV devices provide advanced control of the PLL bandwidth using the programmable characteristics of the PLL loop, including loop filter and charge pump. The closed-loop gain 3-dB frequency in the PLL determines the PLL bandwidth. The bandwidth is approximately the unity gain point for open loop PLL response. Phase Shift Implementation Phase shift is used to implement a robust solution for clock delays in Cyclone IV devices. Phase shift is implemented with a combination of the VCO phase output and the counter starting time. The VCO phase output and counter starting time are the most accurate methods of inserting delays, because they are purely based on counter settings, that are independent of process, voltage, and temperature. You can phase shift the output clocks from the PLLs of Cyclone IV devices in one of two ways: ■ Fine resolution using VCO phase taps ■ Coarse resolution using counter starting time Fine resolution phase shifts are implemented by allowing any of the output counters (C[4..0]) or the M counter to use any of the eight phases of the VCO as the reference clock. This allows you to adjust the delay time with a fine resolution. Equation 5–1 shows the minimum delay time that you can insert using this method. Equation 5–1. Fine Resolution Phase Shift T VCO N 1 Φfine = ----------= -------------- = ----------------8Mf R EF 8 8f VCO in which fREF is the input reference clock frequency. For example, if fREF is 100 MHz, N = 1, and M = 8, then fVCO = 800 MHz, and Φfine = 156.25 ps. The PLL operating frequency defines this phase shift, a value that depends on reference clock frequency and counter settings. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–28 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Phase Shift Implementation Coarse resolution phase shifts are implemented by delaying the start of the counters for a predetermined number of counter clocks. Equation 5–2 shows the coarse phase shift. Equation 5–2. Coarse Resolution Phase Shift C – 1- = -------------------( C – 1 ) NΦcoarse = ----------fVCO MfR EF C is the count value set for the counter delay time (this is the initial setting in the PLL usage section of the compilation report in the Quartus II software). If the initial value is 1, C – 1 = 0° phase shift. Figure 5–18 shows an example of phase shift insertion using fine resolution through VCO phase taps method. The eight phases from the VCO are shown and labeled for reference. For this example, CLK0 is based on 0° phase from the VCO and has the C value for the counter set to one. The CLK1 signal is divided by four, two VCO clocks for high time and two VCO clocks for low time. CLK1 is based on the 135° phase tap from the VCO and has the C value for the counter set to one. The CLK1 signal is also divided by four. In this case, the two clocks are offset by 3 Φfine. CLK2 is based on the 0° phase from the VCO but has the C value for the counter set to three. This creates a delay of two Φcoarse (two complete VCO periods). Figure 5–18. Delay Insertion Using VCO Phase Output and Counter Delay Time 1/8 tVCO tVCO 0 45 90 135 180 225 270 315 CLK0 td0-1 CLK1 td0-2 CLK2 You can use the coarse and fine phase shifts to implement clock delays in Cyclone IV devices. Cyclone IV devices support dynamic phase shifting of VCO phase taps only. The phase shift is configurable for any number of times. Each phase shift takes about one scanclk cycle, allowing you to implement large phase shifts quickly. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Cascading 5–29 PLL Cascading Cyclone IV devices allow cascading between GPLLs and MPLLs in normal or direct mode through the GCLK network. If your design cascades PLLs, the source (upstream) PLL must have a low-bandwidth setting, while the destination (downstream) PLL must have a high-bandwidth setting. PLL Reconfiguration PLLs use several divide counters and different VCO phase taps to perform frequency synthesis and phase shifts. In PLLs of Cyclone IV devices, you can reconfigure both counter settings and phase shift the PLL output clock in real time. You can also change the charge pump and loop filter components, which dynamically affects PLL bandwidth. You can use these PLL components to update the output clock frequency, PLL bandwidth, and phase shift in real time, without reconfiguring the entire FPGA. The ability to reconfigure the PLL in real time is useful in applications that might operate at multiple frequencies. It is also useful in prototyping environments, allowing you to sweep PLL output frequencies and adjust the output clock phase dynamically. For instance, a system generating test patterns is required to generate and send patterns at 75 or 150 MHz, depending on the requirements of the device under test. Reconfiguring PLL components in real time allows you to switch between two such output frequencies in a few microseconds. You can also use this feature to adjust clock-to-out (t CO) delays in real time by changing the PLL output clock phase shift. This approach eliminates the need to regenerate a configuration file with the new PLL settings. PLL Reconfiguration Hardware Implementation The following PLL components are configurable in real time: ■ Pre-scale counter (N) ■ Feedback counter (M) ■ Post-scale output counters (C0–C4) ■ Dynamically adjust the charge pump current (ICP) and loop filter components (R, C) to facilitate on-the-fly reconfiguration of the PLL bandwidth Figure 5–19 shows how to adjust PLL counter settings dynamically by shifting their new settings into a serial shift register chain or scan chain. Serial data shifts to the scan chain via the scandataport, and shift registers are clocked by scanclk. The maximum scanclk frequency is 100 MHz. After shifting the last bit of data, asserting the configupdate signal for at least one scanclk clock cycle synchronously updates the PLL configuration bits with the data in the scan registers. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–30 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration Figure 5–19. PLL Reconfiguration Scan Chain FVCO from M counter from N counter PFD LF/K/CP VCO scandata scanclkena configupdate /C4 inclk /C3 /C2 /C1 /C0 /M /N scandataout scandone scanclk 1 The counter settings are updated synchronously to the clock frequency of the individual counters. Therefore, not all counters update simultaneously. To reconfigure the PLL counters, perform the following steps: 1. The scanclkena signal is asserted at least one scanclk cycle prior to shifting in the first bit of scandata (D0). 2. Serial data (scandata) is shifted into the scan chain on the second rising edge of scanclk. 3. After all 144 bits have been scanned into the scan chain, the scanclkena signal is de-asserted to prevent inadvertent shifting of bits in the scan chain. 4. The configupdate signal is asserted for one scanclk cycle to update the PLL counters with the contents of the scan chain. 5. The scandone signal goes high indicating that the PLL is being reconfigured. A falling edge indicates that the PLL counters have been updated with new settings. 6. Reset the PLL using the areset signal if you make any changes to the M, N, post-scale output C counters, or the ICP , R, C settings. 7. You can repeat steps 1 through 5 to reconfigure the PLL any number of times. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration 5–31 Figure 5–20 shows a functional simulation of the PLL reconfiguration feature. Figure 5–20. PLL Reconfiguration Scan Chain scandata D0 (LSB) Dn (MSB) scanclk scanclkena scandataout D0_old Dn_old Dn configupdate scandone areset 1 When reconfiguring the counter clock frequency, the corresponding counter phase shift settings cannot be reconfigured using the same interface. You can reconfigure phase shifts in real time using the dynamic phase shift reconfiguration interface. If you reconfigure the counter frequency, but wish to keep the same non-zero phase shift setting (for example, 90°) on the clock output, you must reconfigure the phase shift after reconfiguring the counter clock frequency. Post-Scale Counters (C0 to C4) You can configure multiply or divide values and duty cycle of post-scale counters in real time. Each counter has an 8-bit high time setting and an 8-bit low time setting. The duty cycle is the ratio of output high or low time to the total cycle time, that is the sum of the two. Additionally, these counters have two control bits, rbypass, for bypassing the counter, and rselodd, to select the output clock duty cycle. When the rbypass bit is set to 1, it bypasses the counter, resulting in a divide by one. When this bit is set to 0, the PLL computes the effective division of the VCO output frequency based on the high and low time counters. For example, if the post-scale divide factor is 10, the high and low count values is set to 5 and 5 respectively, to achieve a 50–50% duty cycle. The PLL implements this duty cycle by transitioning the output clock from high-to-low on the rising edge of the VCO output clock. However, a 4 and 6 setting for the high and low count values, respectively, would produce an output clock with 40–60% duty cycle. The rselodd bit indicates an odd divide factor for the VCO output frequency with a 50% duty cycle. For example, if the post-scale divide factor is three, the high and low time count values are 2 and 1, respectively, to achieve this division. This implies a 67%–33% duty cycle. If you need a 50%–50% duty cycle, you must set the rselodd control bit to 1 to achieve this duty cycle despite an odd division factor. The PLL implements this duty cycle by transitioning the output clock from high-to-low on a falling edge of the VCO output clock. When you set rselodd = 1, subtract 0.5 cycles from the high time and add 0.5 cycles to the low time. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–32 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration For example: ■ High time count = 2 cycles ■ Low time count = 1 cycle ■ rselodd = 1 effectively equals: ■ High time count = 1.5 cycles ■ Low time count = 1.5 cycles ■ Duty cycle = (1.5/3)% high time count and (1.5/3)% low time count Scan Chain Description Cyclone IV PLLs have a 144-bit scan chain. Table 5–5 lists the number of bits for each component of the PLL. Table 5–5. Cyclone IV PLL Reprogramming Bits Number of Bits Block Name Counter Other Total C4 (1) 16 2 (2) 18 C3 16 2 (2) 18 C2 16 2 (2) 18 C1 16 2 (2) 18 C0 16 2 (2) 18 M 16 2 (2) 18 N 16 2 (2) 18 Charge Pump 9 0 9 Loop Filter (3) 9 0 9 Total number of bits: 144 Notes to Table 5–5: (1) LSB bit for C4 low-count value is the first bit shifted into the scan chain. (2) These two control bits include rbypass, for bypassing the counter, and rselodd, to select the output clock duty cycle. (3) MSB bit for loop filter is the last bit shifted into the scan chain. Figure 5–21 shows the scan chain order of the PLL components. Figure 5–21. PLL Component Scan Chain Order DATAIN LF MSB DATAOUT Cyclone IV Device Handbook, Volume 1 CP LSB C4 N M C0 C3 C2 C1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration 5–33 Figure 5–22 shows the scan chain bit order sequence for one PLL post-scale counter in PLLs of Cyclone IV devices. Figure 5–22. Scan Chain Bit Order DATAOUT HB HB HB HB HB HB HB HB HB HB 0 1 2 3 4 5 6 7 8 9 LB LB LB LB LB LB LB LB LB LB 0 1 2 3 4 5 6 7 8 9 rbypass DATAIN rselodd Charge Pump and Loop Filter You can reconfigure the charge pump and loop filter settings to update the PLL bandwidth in real time. Table 5–6 through Table 5–8 list the possible settings for charge pump (ICP), loop filter resistor (R), and capacitor (C) values for PLLs of Cyclone IV devices. Table 5–6. Charge Pump Bit Control CP[2] CP[1] CP[0] Setting (Decimal) 0 0 0 0 1 0 0 1 1 1 0 3 1 1 1 7 Table 5–7. Loop Filter Resistor Value Control © November 2009 LFR[4] LFR[3] LFR[2] LFR[1] LFR[0] Setting (Decimal) 0 0 0 0 0 0 0 0 0 1 1 3 0 0 1 0 0 4 0 1 0 0 0 8 1 0 0 0 0 16 1 0 0 1 1 19 1 0 1 0 0 20 1 1 0 0 0 24 1 1 0 1 1 27 1 1 1 0 0 28 1 1 1 1 0 30 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–34 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration Table 5–8. Loop Filter Control of High Frequency Capacitor LFC[1] LFC[0] Setting (Decimal) 0 0 0 0 1 1 1 1 3 Bypassing a PLL Counter Bypassing a PLL counter results in a divide (N, C0 to C4 counters) factor of one. Table 5–9 lists the settings for bypassing the counters in PLLs of Cyclone IV devices. Table 5–9. PLL Counter Settings PLL Scan Chain Bits [0..8] Settings Description LSB MSB X X X X X X X X 1 (1) PLL counter bypassed X X X X X X X X 0 (1) PLL counter not bypassed Note to Table 5–9: (1) Bypass bit. To bypass any of the PLL counters, set the bypass bit to 1. The values on the other bits are then ignored. Dynamic Phase Shifting The dynamic phase shifting feature allows the output phase of individual PLL outputs to be dynamically adjusted relative to each other and the reference clock without sending serial data through the scan chain of the corresponding PLL. This feature simplifies the interface and allows you to quickly adjust tCO delays by changing output clock phase shift in real time. This is achieved by incrementing or decrementing the VCO phase-tap selection to a given C counter or to the M counter. The phase is shifted by 1/8 the VCO frequency at a time. The output clocks are active during this phase reconfiguration process. Table 5–10 lists the control signals that are used for dynamic phase shifting. Table 5–10. Dynamic Phase Shifting Control Signals (Part 1 of 2) Signal Name Description Source Destination PHASECOUNTERSELECT[2:0] Counter Select. Three bits decoded to select either the M or one of the C counters for phase adjustment. One address map to select all C counters. This signal is registered in the PLL on the rising edge of SCANCLK. Logic array or I/O pins PLL reconfiguration circuit PHASEUPDOWN Selects dynamic phase shift direction; 1= UP, 0 = DOWN. Signal is registered in the PLL on the rising edge of SCANCLK. Logic array or I/O pins PLL reconfiguration circuit PHASESTEP Logic high enables dynamic phase shifting. Logic array or I/O pins PLL reconfiguration circuit Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices PLL Reconfiguration 5–35 Table 5–10. Dynamic Phase Shifting Control Signals (Part 2 of 2) Signal Name Description Source Destination SCANCLK Free running clock from core used in combination with PHASESTEP to enable or disable dynamic phase shifting. Shared with SCANCLK for dynamic reconfiguration. GCLK or I/O pins PLL reconfiguration circuit PHASEDONE When asserted, it indicates to core logic that the phase adjustment is complete and PLL is ready to act on a possible second adjustment pulse. Asserts based on internal PLL timing. De-asserts on the rising edge of SCANCLK. PLL reconfiguration Logic array or circuit I/O pins Table 5–11 lists the PLL counter selection based on the corresponding PHASECOUNTERSELECT setting. Table 5–11. Phase Counter Select Mapping PHASECOUNTERSELECT [2] [1] [0] Selects 0 0 0 All Output Counters 0 0 1 M Counter 0 1 0 C0 Counter 0 1 1 C1 Counter 1 0 0 C2 Counter 1 0 1 C3 Counter 1 1 0 C4 Counter To perform one dynamic phase shift step, you must perform the following procedures: 1. Set phaseupdown and phasecounterselect as required. 2. Assert phasestep for at least two scanclk cycles. Each phasestep pulse enables one phase shift. 3. De-assert phasestep. 4. Wait for phasedone to go high. 5. You can repeat steps 1 through 4 as many times as required to get multiple phase shifts. All signals are synchronous to scanclk, so they are latched on the scanclk edges and must meet tSU or tH requirements (with respect to the scanclk edges). © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 5–36 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Spread-Spectrum Clocking Figure 5–23. PLL Dynamic Phase Shift phaseupdown phasecounterselect scanclk phasestep phasedone Dynamic phase shifting can be repeated indefinitely. All signals are synchronous to scanclk, so they must meet tSU or tH requirements (with respect to scanclk edges). The phasestep signal is latched on the negative edge of scanclk. In Figure 5–23, this is shown by the second scanclk falling edge. phasestep must stay high for at least two scanclk cycles. On the second scanclk rising edge after phasestep is latched (indicated by the fourth rising edge), the values of phaseupdown and phasecounterselect are latched and the PLL starts dynamic phase shifting for the specified counter or counters and in the indicated direction. On the fourth scanclk rising edge, phasedone goes high to low and remains low until the PLL finishes dynamic phase shifting. You can perform another dynamic phase shift after the phasedone signal goes from low to high. Depending on the VCO and scanclk frequencies, phasedone low time may be greater than or less than one scanclk cycle. After phasedone goes from low to high, you can perform another dynamic phase shift. phasestep pulses must be at least one scanclk cycle apart. f For information about the ALTPLL_RECONFIG MegaWizard™ Plug-In Manager, refer to the ALTPLL_RECONFIG Megafunction User Guide. Spread-Spectrum Clocking Cyclone IV devices can accept a spread-spectrum input with typical modulation frequencies. However, the device cannot automatically detect that the input is a spread-spectrum signal. Instead, the input signal looks like deterministic jitter at the input of the PLL. PLLs of Cyclone IV devices can track a spread-spectrum input clock as long as it is in the input jitter tolerance specifications and the modulation frequency of the input clock is below the PLL bandwidth, that is specified in the fitter report. Cyclone IV devices cannot generate spread-spectrum signals internally. PLL Specifications f For information about PLL specifications, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Chapter Revision History 5–37 Chapter Revision History Table 5–12 lists the revision history for this chapter. Table 5–12. Chapter Revision History Date Version November 2009 1.0 © November 2009 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 1 5–38 Cyclone IV Device Handbook, Volume 1 Chapter 5: Clock Networks and PLLs in Cyclone IV Devices Chapter Revision History © November 2009 Altera Corporation Section 2. I/O Interfaces This section provides information about Cyclone® IV device family I/O features and high-speed differential and external memory interfaces. This section includes the following chapters: ■ Chapter 6, I/O Features in Cyclone IV Devices ■ Chapter 7, External Memory Interfaces in Cyclone IV Devices Revision History Refer to each chapter for its own specific revision history. For information about when each chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6. I/O Features in Cyclone IV Devices CYIV-51006-1.0 This chapter describes the I/O and high speed I/O capabilities and features offered in Cyclone® IV devices. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. The I/O capabilities of Cyclone IV devices are driven by the diversification of I/O standards in many low-cost applications, and the significant increase in required I/O performance. Altera’s objective is to create a device that accommodates your key board design needs with ease and flexibility. The I/O flexibility of Cyclone IV devices is increased from the previous generation low-cost FPGAs by allowing all I/O standards to be selected on all I/O banks. Improvements to on-chip termination (OCT) support and the addition of true differential buffers have eliminated the need for external resistors in many applications, such as display system interfaces. High-speed differential I/O standards have become popular in high-speed interfaces because of their significant advantages over single-ended I/O standards. The Cyclone IV devices support LVDS, BLVDS, reduced swing differential signaling (RSDS), mini-LVDS, and point-to-point differential signaling (PPDS). The LVDS I/O standards also support the transceiver reference clocks on top of the existing general purpose I/O clock input features. The Quartus® II software completes the solution with powerful pin planning features that allow you to plan and optimize I/O system designs even before the design files are available. This chapter includes the following sections: © November 2009 ■ “Cyclone IV I/O Elements” on page 6–2 ■ “I/O Element Features” on page 6–3 ■ “OCT Support” on page 6–6 ■ “I/O Standards” on page 6–11 ■ “Termination Scheme for I/O Standards” on page 6–13 ■ “I/O Banks” on page 6–15 ■ “Pad Placement and DC Guidelines” on page 6–20 ■ “High-Speed I/O Interface” on page 6–21 ■ “High-Speed I/O Standards Support” on page 6–22 ■ “True Output Buffer Feature” on page 6–30 ■ “High-Speed I/O Timing” on page 6–31 ■ “Design Guidelines” on page 6–32 ■ “Software Overview” on page 6–33 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–2 Chapter 6: I/O Features in Cyclone IV Devices Cyclone IV I/O Elements Cyclone IV I/O Elements Cyclone IV I/O elements (IOEs) contain a bidirectional I/O buffer and five registers for registering input, output, output-enable signals, and complete embedded bidirectional single-data rate transfer. I/O pins support various single-ended and differential I/O standards. The IOE contains one input register, two output registers, and two output-enable (OE) registers. The two output registers and two OE registers are used for DDR applications. You can use input registers for fast setup times and output registers for fast clock-to-output times. Additionally, you can use OE registers for fast clock-to-output enable timing. You can use IOEs for input, output, or bidirectional data paths. Figure 6–1 shows Cyclone IV devices IOE structure. Figure 6–1. Cyclone IV IOEs in a Bidirectional I/O Configuration for SDR Mode io_clk[5..0] Column or Row Interconnect OE OE Register clkout D VCCIO Q Optional PCI Clamp ENA ACLR /PRN VCCIO oe_out Programmable Pull-Up Resistor aclr/prn Chip-Wide Reset Output Pin Delay Output Register D sclr/ preset Current Strength Control Open-Drain Out Slew Rate Control Q ENA ACLR /PRN data_in1 data_in0 D clkin oe_in Cyclone IV Device Handbook, Volume 1 Q Bus Hold Input Pin to Input Register Delay or Input Pin to Logic Array Delay ENA ACLR /PRN Input Register © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Element Features 6–3 I/O Element Features The Cyclone IV IOE offers a range of programmable features for an I/O pin. These features increase the flexibility of I/O utilization and provide an alternative to reduce the usage of external discrete components to on-chip, such as a pull-up resistors and diodes. Programmable Current Strength The output buffer for each Cyclone IV I/O pin has a programmable current strength control for certain I/O standards. The LVTTL, LVCMOS, SSTL-2 Class I and II, SSTL-18 Class I and II, HSTL-18 Class I and II, HSTL-15 Class I and II, and HSTL-12 Class I and II I/O standards have several levels of current strength that you can control. Table 6–2 on page 6–7 shows the possible settings for I/O standards with current strength control. These programmable current strength settings are a valuable tool in helping decrease the effects of simultaneously switching outputs (SSO) in conjunction with reducing system noise. The supported settings ensure that the device driver meets the specifications for IOH and IOL of the corresponding I/O standard. 1 When you use programmable current strength, on-chip series termination is not available. Slew Rate Control The output buffer for each Cyclone IV devices I/O pin provides optional programmable output slew-rate control. Table 6–2 on page 6–7 shows the possible slew rate option and the Quartus II default slew rate setting. However, these fast transitions may introduce noise transients in the system. A slower slew rate reduces system noise, but adds a nominal delay to rising and falling edges. Because each I/O pin has an individual slew-rate control, you can specify the slew rate on a pin-by-pin basis. The slew-rate control affects both the rising and falling edges. Slew rate control is available for single-ended I/O standards with current strength of 8 mA or higher. 1 You cannot use the programmable slew rate feature when using OCT with calibration. 1 You cannot use the programmable slew rate feature when using the 3.0-V PCI, 3.0-V PCI-X, 3.3-V LVTTL, and 3.3-V LVCMOS I/O standards. Only the fast slew rate (default) setting is available. Open-Drain Output Cyclone IV devices provide an optional open-drain (equivalent to an open-collector) output for each I/O pin. This open-drain output enables the device to provide system-level control signals (for example, interrupt and write enable signals) that are asserted by multiple devices in your system. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–4 Chapter 6: I/O Features in Cyclone IV Devices I/O Element Features Bus Hold Each Cyclone IV device user I/O pin provides an optional bus-hold feature. The bus-hold circuitry holds the signal on an I/O pin at its last-driven state. Because the bus-hold feature holds the last-driven state of the pin until the next input signal is present, an external pull-up or pull-down resistor is not necessary to hold a signal level when the bus is tri-stated. The bus-hold circuitry also pulls undriven pins away from the input threshold voltage in which noise can cause unintended high-frequency switching. You can select this feature individually for each I/O pin. The bus-hold output drives no higher than VCCIO to prevent overdriving signals. 1 If you enable the bus-hold feature, the device cannot use the programmable pull-up option. Disable the bus-hold feature when the I/O pin is configured for differential signals. Bus-hold circuitry is not available on dedicated clock pins. Bus-hold circuitry is only active after configuration. When going into user mode, the bus-hold circuit captures the value on the pin present at the end of configuration. f For the specific sustaining current for each VCCIO voltage level driven through the resistor and for the overdrive current used to identify the next driven input level, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Programmable Pull-Up Resistor Each Cyclone IV device I/O pin provides an optional programmable pull-up resistor while in user mode. If you enable this feature for an I/O pin, the pull-up resistor holds the output to the VCCIO level of the output pin’s bank. 1 If you enable the programmable pull-up, the device cannot use the bus-hold feature. Programmable pull-up resistors are not supported on the dedicated configuration, JTAG, and dedicated clock pins. Programmable Delay The Cyclone IV IOE includes programmable delays to ensure zero hold times, minimize setup times, increase clock-to-output times, or delay the clock input signal. A path in which a pin directly drives a register may require a programmable delay to ensure zero hold time, whereas a path in which a pin drives a register through combinational logic may not require the delay. Programmable delays minimize setup time. The Quartus II Compiler can program these delays to automatically minimize setup time while providing a zero hold time. Programmable delays can increase the register-to-pin delays for output registers. Each dual-purpose clock input pin provides a programmable delay to the global clock networks. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Element Features 6–5 Table 6–1 shows the programmable delays for Cyclone IV devices. Table 6–1. Cyclone IV Devices Programmable Delay Chain Programmable Delay Quartus II Logic Option Input pin-to-logic array delay Input delay from pin to internal cells Input pin-to-input register delay Input delay from pin to input register Output pin delay Delay from output register to output pin Dual-purpose clock input pin delay Input delay from dual-purpose clock pin to fan-out destinations There are two paths in the IOE for an input to reach the logic array. Each of the two paths can have a different delay. This allows you to adjust delays from the pin to the internal logic element (LE) registers that reside in two different areas of the device. You must set the two combinational input delays with the input delay from pin to internal cells logic option in the Quartus II software for each path. If the pin uses the input register, one of the delays is disregarded and the delay is set with the input delay from pin to input register logic option in the Quartus II software. The IOE registers in each I/O block share the same source for the preset or clear features. You can program preset or clear for each individual IOE, but you cannot use both features simultaneously. You can also program the registers to power-up high or low after configuration is complete. If programmed to power-up low, an asynchronous clear can control the registers. If programmed to power-up high, an asynchronous preset can control the registers. This feature prevents the inadvertent activation of the active-low input of another device upon power-up. If one register in an IOE uses a preset or clear signal, all registers in the IOE must use that same signal if they require preset or clear. Additionally, a synchronous reset signal is available for the IOE registers. f © November 2009 For more information about the input and output pin delay settings, refer to the Area and Timing Optimization chapter in volume 2 of the Quartus II Handbook. Altera Corporation Cyclone IV Device Handbook, Volume 1 6–6 Chapter 6: I/O Features in Cyclone IV Devices OCT Support PCI-Clamp Diode Cyclone IV devices provide an optional PCI-clamp diode enabled input and output for each I/O pin. Dual-purpose configuration pins support the diode in user mode if the specific pins are not used as configuration pins for the selected configuration scheme. For example, if you are using the active serial (AS) configuration scheme, you cannot use the clamp diode on the ASDO and nCSO pins in user mode. Dedicated configuration pins do not support the on-chip diode. The PCI-clamp diode is available for the following I/O standards: ■ 3.3-V LVTTL ■ 3.3-V LVCMOS ■ 3.0-V LVTTL ■ 3.0-V LVCMOS ■ 2.5-V LVTTL/LVCMOS ■ PCI ■ PCI-X If the input I/O standard is 3.3-V LVTTL, 3.3-V LVCMOS, 3.0-V LVTTL, 3.0-V LVCMOS, 2.5-V LVTTL/LVCMOS, PCI, or PCI-X, the PCI-clamp diode is enabled by default in the Quartus II software. OCT Support Cyclone IV devices feature OCT to provide I/O impedance matching and termination capabilities. OCT helps to prevent reflections and maintain signal integrity while minimizing the need for external resistors in high pin-count ball grid array (BGA) packages. Cyclone IV devices provide I/O driver on-chip impedance matching and on-chip series termination for single-ended outputs and bidirectional pins. 1 When using on-chip series termination, programmable current strength is not available. There are two ways to implement OCT in Cyclone IV devices: ■ OCT with calibration ■ OCT without calibration Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices OCT Support 6–7 Table 6–2 lists the I/O standards that support impedance matching and series termination. Table 6–2. Cyclone IV Device I/O Features Support (Part 1 of 2) IOH/IOL Current Strength Setting (mA) (1) I/O Standard 3.3-V LVTTL 3.0-V LVCMOS I/O Banks Slew Rate Option (6) PCIclamp Diode Support Right I/O Pins Row I/O Column I/O Row I/O Column I/O 4,8 4,8 — — — — — v 2 2 — — — — — v 4,8,12,16 4,8,12,16 50,25 50,25 50,25 50,25 4,8,12,16 3.0-V PCI/PCI-X On-Chip Series Termination Without Calibration Setting, Ohm (Ω) Top and Bottom I/O Pins 3.3-V LVCMOS 3.0-V LVTTL On-Chip Series Termination with Calibration Setting, Ohm (Ω) 4,8,12,16 50,25 50,25 50,25 50,25 0,1,2 3,4,5,6,7, 8,9 — v v v — — — — — — 2.5-V LVTTL/LVCMOS 4,8,12,16 4,8,12,16 50,25 50,25 50,25 50,25 v 1.8-V LVTTL/LVCMOS 2,4,6,8,10,12,16 2,4,6,8,10,12,16 50,25 50,25 50,25 50,25 — 1.5-V LVCMOS 2,4,6,8,10,12,16 2,4,6,8,10,12,16 50,25 50,25 50,25 50,25 — 1.2-V LVCMOS 2,4,6,8,10,12 2,4,6,8,10 50 50,25 50 50,25 SSTL-2 Class I 8,12 8,12 50 50 50 50 — SSTL-2 Class II 16 16 25 25 25 25 — SSTL-18 Class I 8,10,12 8,10,12 50 50 50 50 — SSTL-18 Class II 12,16 12,16 25 25 25 25 HSTL-18 Class I 8,10,12 8,10,12 50 50 50 50 — 4,5,6,7,8 — 3,4,5,6,7, 8,9 — HSTL-18 Class II 16 16 25 25 25 25 — HSTL-15 Class I 8,10,12 8,10,12 50 50 50 50 — HSTL-15 Class II 16 16 25 25 25 25 — 0,1,2 HSTL-12 Class I 8,10,12 8,10 50 50 50 50 4,5,6,7,8 — HSTL-12 Class II 4,7,8 — 14 — — 25 — 25 Differential SSTL-2 Class I (2), (7) 8,12 8,12 50 50 50 50 — Differential SSTL-2 Class II (2), (7) 16 16 25 25 25 25 — Differential SSTL-18 (2), (7) 8,10,12 8,10,12 — 50 — 50 Differential HSTL-18 (2), (7) 8,10,12 8,10,12 — 50 — 50 — Differential HSTL-15 (2), (7) 8,10,12 8,10,12 — 50 — 50 — Differential HSTL-12 (2), (8) 8,10,12 8,10,12 — 50 — 50 4,7,8 BLVDS 8,12,16 8,12,16 — — — — 3,4,5,6,7, 8 LVDS (3) — — — — — — PPDS (3), (4) — — — — — — RSDS and mini-LVDS (3), (4) — — — — — — © November 2009 Altera Corporation 3,4,5,6,7, 8 5,6 — — 0,1,2 — — — — — — — Cyclone IV Device Handbook, Volume 1 6–8 Chapter 6: I/O Features in Cyclone IV Devices OCT Support Table 6–2. Cyclone IV Device I/O Features Support (Part 2 of 2) On-Chip Series Termination with Calibration Setting, Ohm (Ω) IOH/IOL Current Strength Setting (mA) (1) I/O Standard Differential LVPECL (5) On-Chip Series Termination Without Calibration Setting, Ohm (Ω) Top and Bottom I/O Pins Right I/O Pins Row I/O Column I/O Row I/O Column I/O — — — — — — I/O Banks Slew Rate Option (6) PCIclamp Diode Support 3,4,5,6,7, 8 — — Notes to Table 6–2: (1) The default current strength setting in the Quartus II software is 50-Ω OCT without calibration for all non-voltage reference and HSTL/SSTL Class I I/O standards. The default setting is 25-Ω OCT without calibration for HSTL/SSTL Class II I/O standards. (2) These differential I/O standards are supported only for clock inputs and dedicated PLL_OUT outputs. (3) True differential (PPDS, LVDS, mini-LVDS, and RSDS I/O standards) outputs are supported in row I/O banks only. Differential outputs in column I/O banks require an external resistor network. (4) This I/O standard is supported for outputs only. (5) This I/O standard is supported for clock inputs only (6) The default Quartus II slew rate setting is in bold; 2 for all I/O standards that supports slew rate option. (7) The differential SSTL-18 and SSTL-2, differential HSTL-18, and HSTL-15 I/O standards are supported only on clock input pins and PLL output clock pins. Differential SSTL-18, differential HSTL-18, and HSTL-15 I/O standards do not support Class II output. (8) The differential HSTL-12 I/O standard is only supported on clock input pins and PLL output clock pins. Differential HSTL-12 Class II is supported only in column I/O Banks 4, 7, and 8. 1 For more details about the differential I/O standards supported in Cyclone IV Devices I/O Banks, refer to Table 6–5 on page 6–21 in “High-Speed I/O Interface” on page 6–21. On-Chip Series Termination with Calibration Cyclone IV devices support on-chip series termination with calibration in the top, bottom, and right I/O banks. The on-chip series termination calibration circuit compares the total impedance of the I/O buffer to the external 25-Ω ±1% or 50-Ω±1% resistors connected to the RUP and RDN pins, and dynamically adjusts the I/O buffer impedance until they match (as shown in Figure 6–2). The R S shown in Figure 6–2 is the intrinsic impedance of the transistors that make up the I/O buffer. Figure 6–2. Cyclone IV Devices On-Chip Series Termination with Calibration Cyclone IV Device Family Driver Series Termination Receiving Device VCCIO RS ZO RS GND Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices OCT Support 6–9 OCT with calibration is achieved using the OCT calibration block circuitry. There is one OCT calibration block in each I/O Bank 4, 5, and 7. Each calibration block supports each side of the I/O banks. Because there are two I/O banks sharing the same calibration block, both banks must have the same VCCIO if both banks enable OCT calibration. If two related banks have different V CCIO, only the bank in which the calibration block resides can enable OCT calibration. Figure 6–9 on page 6–16 shows the top-level view of the OCT calibration blocks placement. Each calibration block comes with a pair of RUP and RDN pins. When used for calibration, the RUP pin is connected to VCCIO through an external 25-Ω ±1% or 50-Ω ±1% resistor for an on-chip series termination value of 25 Ω or 50 Ω, respectively. The RDN pin is connected to GND through an external 25-Ω ±1% or 50-Ω ±1% resistor for an on-chip series termination value of 25 Ω or 50 Ω, respectively. The external resistors are compared with the internal resistance using comparators. The resultant outputs of the comparators are used by the OCT calibration block to dynamically adjust buffer impedance. 1 During calibration, the resistance of the RUP and RDN pins varies. Figure 6–3 shows the external calibration resistors setup on the RUP and RDN pins and the associated OCT calibration circuitry. Figure 6–3. Cyclone IV Devices On-Chip Series Termination with Calibration Setup Cyclone IV Device Family OCT with Calibration with RUP and RDN pins VCCIO External Calibration Resistor RUP OCT Calibration Circuitry VCCIO RDN External Calibration Resistor GND RUP and RDN pins go to a tri-state condition when calibration is completed or not running. These two pins are dual-purpose I/Os and function as regular I/Os if you do not use the calibration circuit. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–10 Chapter 6: I/O Features in Cyclone IV Devices OCT Support On-Chip Series Termination Without Calibration Cyclone IV devices support driver impedance matching to match the impedance of the transmission line, that is typically 25 or 50 Ω. When used with the output drivers, OCT sets the output driver impedance to 25 or 50 Ω. Cyclone IV devices also support I/O driver series termination (RS = 50 Ω) for SSTL-2 and SSTL-18. Figure 6–4 shows the single-ended I/O standards for OCT without calibration. The R S shown is the intrinsic transistor impedance. Figure 6–4. Cyclone IV Devices On-Chip Series Termination Without Calibration Cyclone IV Device Driver Series Termination Receiving Device VCCIO RS ZO RS GND All I/O banks and I/O pins support impedance matching and series termination. Dedicated configuration pins and JTAG pins do not support impedance matching or series termination. On-chip series termination is supported on any I/O bank. VCCIO and VREF must be compatible for all I/O pins to enable on-chip series termination in a given I/O bank. I/O standards that support different RS values can reside in the same I/O bank as long as their V CCIO and VREF are not conflicting. Impedance matching is implemented using the capabilities of the output driver and is subject to a certain degree of variation, depending on the process, voltage, and temperature. f For more information about tolerance specification, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Standards 6–11 I/O Standards Cyclone IV devices support multiple single-ended and differential I/O standards. Cyclone IV devices support 3.3-, 3.0-, 2.5-, 1.8-, 1.5-, and 1.2-V I/O standards. Table 6–3 summarizes I/O standards supported by Cyclone IV devices and which I/O pins support them. Table 6–3. Cyclone IV Devices Supported I/O Standards and Constraints (Part 1 of 2) VC CIO Level (in V) I/O Standard Type Standard Support Top and Bottom I/O Pins Right I/O Pins Input Output CLK, DQS PLL_OUT User I/O Pins CLK, DQS User I/O Pins 3.3-V LVTTL, 3.3-V LVCMOS (1) Single-ended JESD8-B 3.3/3.0/2.5 (2) 3.3 v v v v v 3.0-V LVTTL, 3.0-V LVCMOS (1) Single-ended JESD8-B 3.3/3.0/2.5 (2) 3.0 v v v v v 2.5-V LVTTL / LVCMOS Single-ended JESD8-5 3.3/3.0/2.5 (2) 2.5 v v v v v 1.8-V LVTTL / LVCMOS Single-ended JESD8-7 1.8/1.5(2) 1.8 v v v v v 1.5-V LVCMOS Single-ended JESD8-11 1.8/1.5(2) 1.5 v v v v v 1.2-V LVCMOS (3) Single-ended JESD8-12A 1.2 1.2 v v v v v SSTL-2 Class I, SSTL-2 Class II voltagereferenced JESD8-9A 2.5 2.5 v v v v v SSTL-18 Class I, SSTL-18 Class II voltagereferenced JESD815 1.8 1.8 v v v v v HSTL-18 Class I, HSTL-18 Class II voltagereferenced JESD8-6 1.8 1.8 v v v v v HSTL-15 Class I, HSTL-15 Class II voltagereferenced JESD8-6 1.5 1.5 v v v v v HSTL-12 Class I voltagereferenced JESD8-16A 1.2 1.2 v v v v v HSTL-12 Class II (8) voltagereferenced JESD8-16A 1.2 1.2 v v v — — PCI and PCI-X Single-ended 3.0 3.0 v v v v v Differential SSTL-2 Class I or Class II Differential (4) JESD8-9A — 2.5 — v — — — 2.5 — v — — v — Differential SSTL-18 Class I or Class II Differential (4) JESD815 — 1.8 — v — — — 1.8 — v — — v — — 1.8 — v — — — 1.8 — v — — v — — 1.5 — v — — — 1.5 — v — — v — — 1.2 — v — — — 1.2 — v — — v — — Differential HSTL-18 Class I or Class II Differential (4) JESD8-6 Differential HSTL-15 Class I or Class II Differential (4) JESD8-6 Differential HSTL-12 Class I or Class II Differential (4) JESD8-16A © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–12 Chapter 6: I/O Features in Cyclone IV Devices I/O Standards Table 6–3. Cyclone IV Devices Supported I/O Standards and Constraints (Part 2 of 2) VC CIO Level (in V) I/O Standard Type Top and Bottom I/O Pins Right I/O Pins Standard Support Input Output CLK, DQS PLL_OUT User I/O Pins CLK, DQS User I/O Pins PPDS (5) Differential — — 2.5 — v v — v LVDS (9) Differential ANSI/TIA/ EIA-644 2.5 2.5 v v v v v RSDS and mini-LVDS (5) Differential — — 2.5 — v v — v BLVDS (7) Differential — 2.5 2.5 — — v — v LVPECL (6) Differential — 2.5 — v — — v — Notes to Table 6–3: (1) The PCI-clamp diode must be enabled for 3.3-V/3.0-V LVTTL/LVCMOS. (2) The Cyclone IV architecture supports the MultiVolt I/O interface feature that allows Cyclone IV devices in all packages to interface with I/O systems that have different supply voltages. (3) 1.2-V VCCIO is not supported in Banks 3 and 9. I/O pins in Bank 9 are dual-purpose I/O pins that are used as configuration or general-purpose I/O (GPIO) pins. Configuration scheme is not support at 1.2 V, therefore Bank 9 can not be powered up at 1.2-V V CCIO. (4) Differential HSTL and SSTL outputs use two single-ended outputs with the second output programmed as inverted. Differential HSTL and SSTL inputs treat differential inputs as two single-ended HSTL and SSTL inputs and only decode one of them. Differential HSTL and SSTL are only supported on CLK pins. (5) PPDS, mini-LVDS, and RSDS are only supported on output pins. (6) LVPECL is only supported on clock inputs. (7) Bus LVDS (BLVDS) output uses two single-ended outputs with the second output programmed as inverted. BLVDS input uses LVDS input buffer. (8) 1.2-V HSTL input is supported at both column and row I/Os regardless of Class I or Class II. (9) True LVDS, RSDS, and mini-LVDS I/O standards are supported in right I/O pins, while emulated LVDS, RSDS, and mini-LVDS I/O standards are supported in the top, bottom, and right I/O pins. Cyclone IV devices support PCI and PCI-X I/O standards at 3.0-V VCCIO. The 3.0-V PCI and PCI-X I/O are fully compatible for direct interfacing with 3.3-V PCI systems without requiring any additional components. The 3.0-V PCI and PCI-X outputs meet the VIH and VIL requirements of 3.3-V PCI and PCI-X inputs with sufficient noise margin. f For more information about the 3.3/3.0/2.5-V LVTTL & LVCMOS multivolt I/O support, refer to the AN 447: Interfacing Cyclone III and Cyclone IV Devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O Systems. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices Termination Scheme for I/O Standards 6–13 Termination Scheme for I/O Standards This section describes recommended termination schemes for voltage-referenced and differential I/O standards. The 3.3-V LVTTL, 3.0-V LVTTL and LVCMOS, 2.5-V LVTTL and LVCMOS, 1.8-V LVTTL and LVCMOS, 1.5-V LVCMOS, 1.2-V LVCMOS, 3.0-V PCI, and PCI-X I/O standards do not specify a recommended termination scheme per the JEDEC standard Voltage-Referenced I/O Standard Termination Voltage-referenced I/O standards require an input reference voltage (V REF) and a termination voltage (VTT). The reference voltage of the receiving device tracks the termination voltage of the transmitting device, as shown in Figure 6–5 and Figure 6–6. Figure 6–5. Cyclone IV Devices HSTL I/O Standard Termination HSTL Class I Termination HSTL Class II VTT External On-Board Termination Cyclone IV Device Family Series OCT 50 Ω © November 2009 Altera Corporation 50 Ω 50 Ω VREF Receiver VTT Transmitter Cyclone IV Device Family Series OCT 25 Ω 50 Ω 50 Ω VREF Transmitter VTT 50 Ω 50 Ω VREF Transmitter OCT with and without Calibration VTT 50 Ω Receiver VTT VTT 50 Ω 50 Ω 50 Ω VREF Receiver Transmitter Receiver Cyclone IV Device Handbook, Volume 1 6–14 Chapter 6: I/O Features in Cyclone IV Devices Termination Scheme for I/O Standards Figure 6–6. Cyclone IV Devices SSTL I/O Standard Termination Termination SSTL Class I SSTL Class II VTT 25 Ω External On-Board Termination VTT 50 Ω 50 Ω 25 Ω 50 Ω VREF Transmitter Receiver Cyclone IV Device Family Series OCT 50 Ω 50 Ω 50 Ω VREF Transmitter Receiver Cyclone IV Device Family Series OCT 25 Ω VTT VTT VTT 50 Ω 50 Ω OCT with and without Calibration VTT 50 Ω 50 Ω 50 Ω VREF Transmitter VREF Receiver Transmitter Receiver Differential I/O Standard Termination Differential I/O standards typically require a termination resistor between the two signals at the receiver. The termination resistor must match the differential load impedance of the bus (refer to Figure 6–7 and Figure 6–8). Cyclone IV devices support differential SSTL-2 and SSTL-18, differential HSTL-18, HSTL-15, and HSTL-12, PPDS, LVDS, RSDS, mini-LVDS, and differential LVPECL. Figure 6–7. Cyclone IV Devices Differential HSTL I/O Standard Class I and Class II Interface and Termination Termination Differential HSTL Class I VTT 50 Ω External On-Board Termination VTT Transmitter Cyclone IV Device Handbook, Volume 1 50 Ω VTT VTT 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω Receiver VTT OCT VTT VTT 50 Ω Transmitter Cyclone IV Device Family Series OCT 50 Ω Differential HSTL Class II 50 Ω Transmitter Receiver VTT VTT Cyclone IV Device Family Series OCT 25 Ω 50 Ω VTT 50 Ω VTT 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω Receiver 50 Ω VTT 50 Ω Transmitter Receiver © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Banks 6–15 Figure 6–8. Cyclone IV Devices Differential SSTL I/O Standard Class I and Class II Interface and Termination (Note 1) Termination Differential SSTL Class I VTT 50 Ω 25 Ω External On-Board Termination 25 Ω Transmitter 50 Ω 50 Ω VTT VTT 50 Ω 25 Ω 25 Ω 50 Ω Transmitter VTT Receiver VTT Cyclone IV Device Family Series OCT 25 Ω 50 Ω VTT 50 Ω VTT 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω Receiver 50 Ω 50 Ω 50 Ω Receiver 50 Ω 50 Ω 50 Ω VTT OCT VTT VTT VTT Transmitter Cyclone IV Device Family Series OCT 50 Ω Differential SSTL Class II Transmitter VTT 50 Ω Receiver Note to Figure 6–8: (1) Only Differential SSTL-2 I/O standard supports Class II output. I/O Banks I/O pins on Cyclone IV devices are grouped together into I/O banks, and each bank has a separate power bus. Cyclone IV devices have up to ten I/O banks and one configuration bank, as shown in Figure 6–9 and Figure 6–10. The configuration I/O bank contains three user I/O pins with secondary configuration programming functions. They can be used as normal user I/O pins if they are not used in configuration modes. Each device I/O pin is associated with one I/O bank. All singleended I/O standards are supported except HSTL-12 Class II, which is only supported in column I/O banks. All differential I/O standards are supported in top, bottom, and right I/O banks. The only exception is HSTL-12 Class II, which is only supported in column I/O banks. The entire left side of the Cyclone IV devices contain dedicated high-speed transceiver blocks for high speed serial interface applications. There are a total of 2, 4 and 8 channels for Cyclone IV devices depending on the density and package of the device. For more information about the transceiver channels supported, refer to Figure 6–9 and Figure 6–10 on page 6–17. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–16 Chapter 6: I/O Features in Cyclone IV Devices I/O Banks Figure 6–9 and Figure 6–10 show the overview of Cyclone IV I/O banks. Figure 6–9. Cyclone IV Devices I/O Banks for EP4CGX15, EP4CGX22, and EP4CGX30 (Note 1), (2), (9) Configuration pins VCCIO8 VCCIO9 I/O Bank 9 (11) I/O Bank 8 (10) I/O Bank 7 I/O Bank 3 (10) VCCIO3 Configuration pins I/O Bank 3A VCC_CLKIN3A I/O Bank 6 VCCIO6 I/O bank with calibration block I/O bank without calibration block I/O Bank 5 PCIe hard IP x1, x2, and x4 Channel 2 I/O Bank 8A 3.3-V LVTTL/LVCMOS 3.0-V LVTTL/LVCMOS 2.5-V LVTTL/LVCMOS 1.8-V LVTTL/LVCMOS 1.5-V LVCMOS 1.2-V LVCMOS PPDS LVDS RSDS mini-LVDS Bus LVDS (7) LVPECL (3) SSTL-2 class I and II SSTL-18 CLass I and II HSTL-18 Class I and II HSTL-15 Class I and II HSTL-12 Class I and II (4) Differential SSTL-2 (5) Differential SSTL-18 (5) Differential HSTL-18 (5) Differential HSTL-15 (5) Differential HSTL-12 (6) 3.0-V PCI/PCI-X (8) Channel 0 Channel 1 VCCIO7 Right, Top, and Bottom Banks Support: Channel 3 Configuration pins VCC_CLKIN8A Calibration block coverage VCCIO5 I/O Bank 4 VCCIO4 Notes to Figure 6–9: (1) This is a top view of the silicon die. For exact pin locations, refer to the pin list and the Quartus II software. Channels 2 and 3 are not available in EP4CGX15 and F169 package type in EP4CGX22 and EP4CGX30 devices. (2) True differential (PPDS, LVDS, mini-LVDS, and RSDS I/O standards) outputs are supported in row I/O Banks 5 and 6 only. External resistors are needed for the differential outputs in column I/O banks. (3) The LVPECL I/O standard is only supported on clock input pins. This I/O standard is not supported on output pins. (4) The HSTL-12 Class II is supported in column I/O Banks 4, 7, and 8. (5) The differential SSTL-18 and SSTL-2, differential HSTL-18, and HSTL-15 I/O standards are supported only on clock input pins and phase-locked loops (PLLs) output clock pins. PLL output clock pins do not support Class II interface type of differential SSTL-18, HSTL-18, HSTL-15, and HSTL-12 I/O standards. (6) The differential HSTL-12 I/O standard is only supported on clock input pins and PLL output clock pins. Differential HSTL-12 Class II is supported only in column I/O Banks 4, 7, and 8. (7) BLVDS output uses two single-ended outputs with the second output programmed as inverted. BLVDS input uses the LVDS input buffer. (8) The PCI-X I/O standard does not meet the IV curve requirement at the linear region. (9) The OCT block is located in the shaded Banks 4,5, and 7. (10) There are two dedicated clock input I/O banks (I/O Bank 3A and I/O Bank 8A) for high-speed serial interface (HSSI) input reference clock pin. (11) There are dual-purpose I/O pins in Bank 9. If input pins with VREF I/O standards are used on these dual-purpose I/O pins during user mode, it will share the VREF pin in Bank 8.These dual-purpose IO pins in Bank 9 when used in user mode also support series OCT without calibration and it share the OCT block with Bank 8. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Banks 6–17 Figure 6–10. Cyclone IV Devices I/O Banks for EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 (Note 1), (2), (9) Configuration pins VCCIO9 I/O Bank 9 I/O Bank 8B I/O Bank 8 (10) I/O Bank 7 Ch3 PCIe hard IP x1, x2, and x4 I/O Bank 3B I/O Bank 3 (10) VCC_CLKIN3B I/O Bank 3A VCCIO3 VCC_CLKIN3A I/O Bank 6 Ch2 3.3-V LVTTL/LVCMOS 3.0-V LVTTL/LVCMOS 2.5-V LVTTL/LVCMOS 1.8-V LVTTL/LVCMOS 1.5-V LVCMOS 1.2-V LVCMOS PPDS LVDS RSDS mini-LVDS Bus LVDS (7) LVPECL (3) SSTL-2 class I and II SSTL-18 CLass I and II HSTL-18 Class I and II HSTL-15 Class I and II HSTL-12 Class I and II (4) Differential SSTL-2 (5) Differential SSTL-18 (5) Differential HSTL-18 (5) Differential HSTL-15 (5) Differential HSTL-12 (6) 3.0-V PCI/PCI-X (8) Ch1 GXBL1 I/O Bank 8A VCCIO7 Right, Top, and Bottom Banks Support: Ch0 Ch3 Ch2 GXBL0 Ch1 Ch0 VCCIO8 VCC_CLKIN8A VCCIO6 I/O bank with calibration block I/O bank without calibration block I/O Bank 5 Configuration pins VCC_CLKIN8B Calibration block coverage VCCIO5 I/O Bank 4 VCCIO4 Configuration pins Notes to Figure 6–10: (1) This is a top view of the silicon die. For exact pin locations, refer to the pin list and the Quartus II software. (2) True differential (PPDS, LVDS, mini-LVDS, and RSDS I/O standards) outputs are supported in row I/O Banks 5 and 6 only. External resistors are needed for the differential outputs in column I/O banks. (3) The LVPECL I/O standard is only supported on clock input pins. This I/O standard is not supported on output pins. (4) The HSTL-12 Class II is supported in column I/O Banks 4, 7, and 8. (5) The differential SSTL-18 and SSTL-2, differential HSTL-18, and HSTL-15 I/O standards are supported only on clock input pins and phase-locked loops (PLLs) output clock pins. PLL output clock pins do not support Class II interface type of differential SSTL-18, HSTL-18, HSTL-15, and HSTL-12 I/O standards. (6) The differential HSTL-12 I/O standard is only supported on clock input pins and PLL output clock pins. Differential HSTL-12 Class II is supported only in column I/O Banks 4, 7, and 8. (7) BLVDS output uses two single-ended outputs with the second output programmed as inverted. BLVDS input uses the LVDS input buffer. (8) The PCI-X I/O standard does not meet the IV curve requirement at the linear region. (9) The OCT block is located in the shaded Banks 4,5, and 7. (10) There are four dedicated clock input I/O banks (I/O Bank 3A, I/O Bank 3B, I/O Bank 8A, and I/O Bank 8B) for HSSI input reference clock pin. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–18 Chapter 6: I/O Features in Cyclone IV Devices I/O Banks Each Cyclone IV I/O bank has a VREF bus to accommodate voltage-referenced I/O standards. Each VREF pin is the reference source for its VREF group. If you use a VREF group for voltage-referenced I/O standards, connect the VREF pin for that group to the appropriate voltage level. If you do not use all the V REF groups in the I/O bank for voltage-referenced I/O standards, you can use the VREF pin in the unused voltage-referenced groups as regular I/O pins. For example, if you have SSTL-2 Class I input pins in I/O Bank 3 and they are all placed in the VREFB1N[0] group, VREFB1N[0] must be powered with 1.25 V, and the remaining VREFB1N[1..3] pins (if available) are used as I/O pins. If multiple VREF groups are used in the same I/O bank, the VREF pins must all be powered by the same voltage level because the VREF pins are shorted together within the same I/O bank. 1 When VREF pins are used as regular I/Os, they have higher pin capacitance than regular user I/O pins. This has an impact on the timing if the pins are used as inputs and outputs. f For more information about VREF pin capacitance, refer to the pin capacitance section in the Cyclone IV Device Data Sheet chapter in volume 3. f For information about how to identify VREF groups, refer to the Cyclone IV Device PinOut files or the Quartus II Pin Planner tool. Table 6–4 summarizes the number of VREF pins in each I/O bank for Cyclone IV devices. Table 6–4. Number of VREF Pins Per I/O Bank for Cyclone IV Devices Device I/O Bank (1) 4CGX15 148QFN 169FBGA 4CGX22 169FBGA 4CGX30 324- 169- 324FBGA FBGA FBGA 4CGX50 484FBGA 672FBGA 4CGX75 484- 672- 484FBGA FBGA FBGA 4CGX110 672FBGA 4CGX150 896- 484- 672FBGA FBGA FBGA 3 1 1 1 3 3 3 3 4 1 1 1 3 3 3 3 5 1 1 1 3 3 3 3 6 1 1 1 3 3 3 3 7 1 1 1 3 3 3 3 8(2) 1 1 1 3 3 3 3 896FBGA Notes to Table 6–4: (1) User I/O pins are used as inputs or outputs; clock input pins are used as inputs only; clock output pins are used as output only. (2) Bank 9 does not have VREF pin. If input pins with VREF I/O standards are used in Bank 9 during user mode, it will share the VREF pin in Bank 8. Each Cyclone IV I/O bank has its own VCCIO pins. Each I/O bank can support only one VCCIO setting from among 1.2, 1.5, 1.8, 3.0, or 3.3 V. Any number of supported single-ended or differential standards can be simultaneously supported in a single I/O bank, as long as they use the same VCCIO levels for input and output pins. When designing LVTTL/LVCMOS inputs with Cyclone IV devices, refer to the following guidelines: ■ All pins accept input voltage (VI) up to a maximum limit (3.6 V), as stated in the recommended operating conditions provided in the Cyclone IV Device Data Sheet chapter in volume 3. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices I/O Banks 6–19 ■ Whenever the input level is higher than the bank V CCIO, expect higher leakage current. ■ The LVTTL/LVCMOS I/O standard input pins can only meet the VIH and VIL levels according to bank voltage level. Voltage-referenced standards are supported in an I/O bank using any number of single-ended or differential standards, as long as they use the same V REF and VCCIO values. For example, if you choose to implement both SSTL-2 and SSTL-18 in your Cyclone IV devices, I/O pins using these standards—because they require different VREF values—must be in different banks from each other. However, the same I/O bank can support SSTL-2 and 2.5-V LVCMOS with the VCCIO set to 2.5 V and the VREF set to 1.25 V. 1 When using Cyclone IV devices as a receiver in 3.3-, 3.0-, or 2.5-V LVTTL/LVCMOS systems, you are responsible for managing overshoot or undershoot to stay in the absolute maximum ratings and the recommended operating conditions, provided in the Cyclone IV Device Data Sheet chapter in volume 3. 1 The PCI clamping diode is enabled by default in the Quartus II software for input signals with bank VCCIO at 2.5, 3.0, or 3.3 V. High-Speed Differential Interfaces Cyclone IV devices can send and receive data through LVDS signals. For the LVDS transmitter and receiver, the input and output pins of Cyclone IV devices support serialization and deserialization through internal logic. The BLVDS extends the benefits of LVDS to multipoint applications such as in bidirectional backplanes. The loading effect and the need to terminate the bus at both ends for multipoint applications require BLVDS to drive out a higher current than LVDS to produce a comparable voltage swing. All the I/O banks of Cyclone IV devices support BLVDS for user I/O pins. The reduced swing differential signaling (RSDS) and mini-LVDS standards are derivatives of the LVDS standard. The RSDS and mini-LVDS I/O standards are similar in electrical characteristics to LVDS, but have a smaller voltage swing and therefore provide increased power benefits and reduced electromagnetic interference (EMI). The point-to-point differential signaling (PPDS) standard is the next generation of the RSDS standard introduced by National Semiconductor Corporation. Cyclone IV devices meet the National Semiconductor Corporation PPDS Interface Specification and support the PPDS standard for outputs only. All the I/O banks of Cyclone IV devices support the PPDS standard for output pins only. The LVDS standard does not require an input reference voltage, but it does require a 100-Ω termination resistor between the two signals at the input buffer. An external resistor network is required on the transmitter side for top and bottom I/O banks. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–20 Chapter 6: I/O Features in Cyclone IV Devices Pad Placement and DC Guidelines External Memory Interfacing Cyclone IV devices support I/O standards required to interface with a broad range of external memory interfaces, such as DDR SDRAM, DDR2 SDRAM, and QDR II SRAM. f For more information about Cyclone IV devices external memory interface support, refer to the External Memory Interfaces in Cyclone IV Devices chapter in volume 1. Pad Placement and DC Guidelines Pad Placement Altera recommends that you create a Quartus II design, enter your device I/O assignments and compile your design to validate your pin placement. The Quartus II software checks your pin connections with respect to the I/O assignment and placement rules to ensure proper device operation. These rules are dependent on device density, package, I/O assignments, voltage assignments and other factors that are not fully described in this chapter. f For more information about how the Quartus II software checks I/O restrictions, refer to the I/O Management chapter in volume 2 of the Quartus II Handbook. DC Guidelines For the Quartus II software to automatically check for illegally placed pads according to the DC guidelines, set the DC current sink or source value to Electromigration Current assignment on each of the output pins that are connected to the external resistive load. The programmable current strength setting has an impact on the amount of DC current that an output pin can source or sink. Determine if the current strength setting is sufficient for the external resistive load condition on the output pin. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Interface 6–21 High-Speed I/O Interface Cyclone IV devices I/Os are separated into six user I/O banks with the left side of the device as the transceiver block, as shown in Figure 6–9 on page 6–16. Each bank has an independent power supply. True output drivers for LVDS, RSDS, mini-LVDS, and PPDS are on the right I/O banks. On the right I/O banks, some of the differential pin pairs (p and n pins) of the true output drivers are not located on adjacent pins. In these cases, a power pin is located between the p and n pins. These I/O standards are also supported on all I/O banks using two single-ended output with the second output programmed as inverted, and an external resistor network. True input buffers for these I/O standards are supported on the top, bottom, and right I/O banks except for I/O Bank 9. Table 6–5 summarizes which I/O bank supports these I/O standards in Cyclone IV devices. Table 6–5. Differential I/O Standards Supported in Cyclone IV I/O Banks Differential I/O Standards LVDS RSDS I/O Bank Location External Resistor Network at Transmitter 5,6 Not Required 3,4,5,6,7,8 Three Resistors 5,6 Not Required Transmitter (TX) Receiver (RX) v v v — v — v — 3,4,7,8 Three Resistors 3,4,5,6,7,8 Single Resistor 5,6 Not Required 3,4,5,6,7,8 Three Resistors 5,6 Not Required 3,4,5,6,7,8 Three Resistors BLVDS (1) 3,4,5,6,7,8 Single Resistor v v LVPECL (2) 3,4,5,6,7,8 — — v Differential SSTL-2 (3) 3,4,5,6,7,8 — v v Differential SSTL-18 (3) 3,4,5,6,7,8 — v v Differential HSTL-18 (3) 3,4,5,6,7,8 — v v Differential HSTL-15 (3) 3,4,5,6,7,8 — v v Differential HSTL-12 (3) 4,5,6,7,8 — v v mini-LVDS PPDS Notes to Table 6–5: (1) Transmitter and Receiver fMAX depend on system topology and performance requirement. (2) The LVPECL I/O standard is only supported on dedicated clock input pins. (3) The differential SSTL-2, SSTL-18, HSTL-18, HSTL-15, and HSTL-12 I/O standards are only supported on clock input pins and PLL output clock pins. PLL output clock pins do not support Class II interface type of differential SSTL-18, HSTL-18, HSTL-15, and HSTL-12 I/O standards. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–22 Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support You can use I/O pins and internal logic to implement a high-speed differential interface in Cyclone IV devices. Cyclone IV devices do not contain dedicated serialization or deserialization circuitry. Therefore, shift registers, internal phase-locked loops (PLLs), and I/O cells are used to perform serial-to-parallel conversions on incoming data and parallel-to-serial conversion on outgoing data. The differential interface data serializers and deserializers (SERDES) are automatically constructed in the core logic elements (LEs) with the Quartus II software ALTLVDS megafunction. Table 6–6 shows the total number of supported row and column differential channels in Cyclone IV devices. Table 6–6. Cyclone IV Devices I/O, Differential and XCVRs Channel Count Device 4CGX15 4CGX22 Numbers of Differential Channels (1), (2) 148QFN 169FBGA User I/O(3) 72 72 72 150 User I/O banks 9(4) 9(4) 9(4) LVDS (6) 25 25 XCVRs 2 2 4CGX30 169- 324- 169FBGA FBGA FBGA 4CGX50 4CGX75 4CGX110 4CGX150 324FBGA 484FBGA 672- 484FBGA FBGA 672FBGA 484FBGA 672- 896- 484FBGA FBGA FBGA 672FBGA 896FBGA 72 150 290 310 290 310 270 393 475 270 393 475 9(4) 9(4) 9(4) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 11 (5) 25 64 25 64 109 140 109 140 93 152 216 93 152 216 2 4 2 4 4 8 4 8 4 8 8 4 8 8 Notes to Table 6–6: (1) User I/O pins are used as inputs or outputs; clock input pins are used as inputs only; clock output pins are used as outputs only. (2) For differential pad placement guidelines, refer to “Pad Placement” on page 6–20. (3) The I/O pin count includes all GPIOs, dedicated clock pins, and dual-purpose configuration pins. Transceivers pins and dedicated configuration pins are not included in the pin count. (4) Includes one configuration I/O bank and two dedicated clock input I/O banks for HSSI input reference clock. (5) Includes one configuration I/O bank and four dedicated clock input I/O banks for HSSI input reference clock. (6) The LVDS true receivers are located on the top, bottom, and right I/O banks. True LVDS output transmitter only exists on the right I/O banks. High-Speed I/O Standards Support This section provides information about the high-speed I/O standards and the HSSI input reference clock supported in Cyclone IV devices. High Speed Serial Interface (HSSI) Input Reference Clock Support Cyclone IV devices support the same I/O features for GPIOs with an additional new feature where the current I/O Bank 3A, 3B, 8A, and 8B consist of dedicated dual-purpose clock input pins (CLKIN) that can be used to support the high-speed transceiver input reference clock (REFCLK) features on top of the general-purpose clock input function. The EP4CGX15, EP4CGX22, and EP4CGX30 devices contain two pairs of CLKIN/REFCLK pins located in I/O Banks 3A and 8A. I/O Banks 3B and 8B are not available in EP4CGX15, EP4CGX22, and EP4CGX30 devices. The EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices have a total of four pairs of CLKIN/REFCLK pins located in I/O Banks 3A, 3B, 8A, and 8B. For more information about the CLKIN/REFCLK pin location, refer to Figure 6–9 on page 6–16 and Figure 6–10 on page 6–17. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support 6–23 The CLKIN/REFCLK pins will be powered by dedicated VCC_CLKIN3A, VCC_CLKIN3B, VCC_CLKIN8A, and VCC_CLKIN8B power supplies separately in their respective I/O banks to avoid the different power level requirements in the same bank for GPIO. Table 6–7. Cyclone IV HSSI REFCLK I/O Standard Support Using GPIO CLKIN Pins (Note 1), (2) VCC_CLKIN Level I/O Standard HSSI Protocol LVDS PCIe & GigE LVPECL PCIe & GigE PCIe & GigE 1.2V, 1.5V, 3.3V PCML PCIe & GigE Coupling Differential AC (Need off chip resistor to restore VCM) PCIe & GigE HCSL Differential DC PCIe Termination I/O Pin Type Input Output Column I/O Row I/O Supported I/O Banks Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Off chip 2.5V Not supported Yes No 3A, 3B, 8A, 8B Notes to Table 6–7: (1) The EP4CGX15, EP4CGX22, and EP4CGX30 devices have two pairs of dedicated clock input pins in Banks 3A and 8A for HSSI input reference clock. I/O Banks 3B and 8B are not available in EP4CGX15, EP4CGX22, and EP4CGX30 devices. (2) The EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices have four pairs of dedicated clock input pins in Banks 3A, 3B, 8A, and 8B for HSSI input. f For more information about the AC-coupled termination scheme for the HSSI reference clock, refer to the Cyclone IV Transceivers chapter in volume 2. LVDS I/O Standard Support in Cyclone IV Devices The LVDS I/O standard is a high-speed, low-voltage swing, low power, and general purpose I/O interface standard. Cyclone IV devices meet the ANSI/TIA/EIA-644 standard with the following exceptions: f © November 2009 ■ The maximum differential output voltage (VOD) is increased to 600 mV. The maximum VOD for ANSI specification is 450 mV. ■ The input voltage range is reduced to the range of 1.0 V to 1.6 V, 0.5 V to 1.85 V, or 0 V to 1.8 V based on different frequency ranges. The ANSI/TIA/EIA-644 specification supports an input voltage range of 0 V to 2.4 V. For LVDS I/O standard electrical specifications in Cyclone IV devices, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Altera Corporation Cyclone IV Device Handbook, Volume 1 6–24 Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support Designing with LVDS Cyclone IV devices I/O banks support LVDS I/O standard. The right I/O banks support true LVDS transmitters. On the top and bottom I/O banks, the emulated LVDS transmitters are supported using two single-ended output buffers with external resistors. One of the single-ended output buffers is programmed to have opposite polarity. The LVDS receiver requires an external 100-Ω termination resistor between the two signals at the input buffer. Figure 6–11 shows a point-to-point LVDS interface using Cyclone IV devices true LVDS output and input buffers. Figure 6–11. Cyclone IV Devices LVDS Interface with True Output Buffer on the Right I/O Banks Cyclone IV Device Transmitting Device txout + txout + rxin + 50 Ω 100 Ω 50 Ω txout - rxin - 100 Ω 50 Ω txout - Input Buffer Receiving Device rxin + 50 Ω Cyclone IV Device Family Logic Array rxin - Output Buffer Figure 6–12 shows a point-to-point LVDS interface with Cyclone IV devices LVDS using two single-ended output buffers and external resistors. Figure 6–12. LVDS Interface with External Resistor Network on the Top and Bottom I/O Banks (Note 1) Cyclone IV Device Emulated LVDS Transmitter LVDS Receiver Resistor Network RS 50 Ω RP 100 Ω 50 Ω RS Note to Figure 6–12: (1) RS and RP values are pending characterization. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support 6–25 BLVDS I/O Standard Support in Cyclone IV Devices The BLVDS I/O standard is a high-speed differential data transmission technology that extends the benefits of standard point-to-point LVDS to multipoint configuration that supports bidirectional half-duplex communication. BLVDS differs from standard LVDS by providing a higher drive to achieve similar signal swings at the receiver while loaded with two terminations at both ends of the bus. Figure 6–13 shows a typical BLVDS topology with multiple transmitter and receiver pairs. Figure 6–13. BLVDS Topology with Cyclone IV Devices Transmitters and Receivers VCC VCC 100 kΩ 100 kΩ 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω 50 Ω RT RT 100 k Ω 50 Ω RS 50 Ω Input Data OE RS 50 Ω OE Output Data GND Output Data Input Data Cyclone IV Device Family Input Data Cyclone IV Device Family Output Data Cyclone IV Device Family RS RS OE RS GND RS 50 Ω 50 Ω 50 Ω 100 kΩ The BLVDS I/O standard is supported on the top, bottom, and right I/O banks of Cyclone IV devices. The BLVDS transmitter uses two single-ended output buffers with the second output buffer programmed as inverted, while the BLVDS receiver uses a true LVDS input buffer. The transmitter and receiver share the same pins. An output-enabled (OE) signal is required to tristate the output buffers when the LVDS input buffer receives a signal. f For more information, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Designing with BLVDS The BLVDS bidirectional communication requires termination at both ends of the bus in BLVDS. The termination resistor (R T) must match the bus differential impedance, which in turn depends on the loading on the bus. Increasing the load decreases the bus differential impedance. With termination at both ends of the bus, termination is not required between the two signals at the input buffer. A single series resistor (R S) is required at the output buffer to match the output buffer impedance to the transmission line impedance. However, this series resistor affects the voltage swing at the input buffer. The maximum data rate achievable depends on many factors. 1 © November 2009 Altera recommends that you perform simulation using the IBIS model while considering factors such as bus loading, termination values, and output and input buffer location on the bus to ensure that the required performance is achieved. Altera Corporation Cyclone IV Device Handbook, Volume 1 6–26 Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support RSDS, Mini-LVDS, and PPDS I/O Standard Support in Cyclone IV Devices The RSDS, mini-LVDS, and PPDS I/O standards are used in chip-to-chip applications between the timing controller and the column drivers on the display panels such as LCD monitor panels and LCD televisions. Cyclone IV devices meet the National Semiconductor Corporation RSDS Interface Specification, Texas Instruments mini-LVDS Interface Specification, and National Semiconductor Corporation PPDS Interface Specification to support RSDS, mini-LVDS and PPDS output standards, respectively. f For Cyclone IV devices RSDS, mini-LVDS, and PPDS output electrical specifications, refer to the Cyclone IV Device Data Sheet chapter in volume 3. f For more information about the RSDS I/O standard, refer to the RSDS specification from the National Semiconductor website (www.national.com). Designing with RSDS, Mini-LVDS, and PPDS Cyclone IV devices I/O banks support RSDS, mini-LVDS, and PPDS output standards. The right I/O banks support true RSDS, mini-LVDS, and PPDS transmitters. On the top and bottom I/O banks, RSDS, mini-LVDS, and PPDS transmitters are supported using two single-ended output buffers with external resistors. The two-single ended output buffers are programmed to have opposite polarity. Figure 6–14 shows an RSDS, mini-LVDS, or PPDS interface with a true output buffer. Figure 6–14. Cyclone IV Devices RSDS, Mini-LVDS, or PPDS Interface with True Output Buffer on the Right I/O Banks Cyclone IV Device True RSDS, Mini-LVDS, or PPDS Transmitter RSDS, Mini-LVDS, or PPDS Receiver 50 Ω 100 Ω 50 Ω Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support 6–27 Figure 6–15 shows an RSDS, mini-LVDS, or PPDS interface with two singled-ended output buffers and external resistors. Figure 6–15. RSDS, Mini-LVDS, or PPDS Interface with External Resistor Network on the Top and Bottom I/O Banks (Note 1) Cyclone IV Device Emulated RSDS, Mini-LVDS, or PPDS Transmitter Resistor Network RSDS, Mini-LVDS, or PPDS Receiver RS 50 Ω 100 Ω RP 50 Ω RS Note to Figure 6–15: (1) RS and RP values are pending characterization. A resistor network is required to attenuate the output voltage swing to meet RSDS, mini-LVDS, and PPDS specifications when using emulated transmitters. You can modify the resistor network values to reduce power or improve the noise margin. The resistor values chosen must satisfy Equation 6–1. Equation 6–1. Resistor Network R R S × -----P2 -------------------- = 50 Ω RP R S + -----2 1 Altera recommends that you perform simulations using Cyclone IV devices IBIS models to validate that custom resistor values meet the RSDS, mini-LVDS, or PPDS requirements. It is possible to use a single external resistor instead of using three resistors in the resistor network for an RSDS interface, as shown in Figure 6–16. The external single-resistor solution reduces the external resistor count while still achieving the required signaling level for RSDS. However, the performance of the single-resistor solution is lower than the performance with the three-resistor network. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–28 Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support Figure 6–16 shows the RSDS interface with a single resistor network on the top and bottom I/O banks. Figure 6–16. RSDS Interface with Single Resistor Network on the Top and Bottom I/O Banks Cyclone IV Device Emulated RSDS Transmitter RSDS Receiver Single Resistor Network 50 Ω 100 Ω RP 50 Ω Note to Figure 6–16: (1) RP value is pending characterization. LVPECL I/O Support in Cyclone IV Devices The LVPECL I/O standard is a differential interface standard that requires a 2.5-V VCCIO. This standard is used in applications involving video graphics, telecommunications, data communications, and clock distribution. Cyclone IV devices support the LVPECL input standard at the dedicated clock input pins only. The LVPECL receiver requires an external 100-Ω termination resistor between the two signals at the input buffer. f For the LVPECL I/O standard electrical specification, refer to the Cyclone IV Device Data Sheet chapter in volume 3. AC coupling is required when the LVPECL common mode voltage of the output buffer is higher than the Cyclone IV devices LVPECL input common mode voltage. Figure 6–17 shows the AC-coupled termination scheme. The 50-Ω resistors used at the receiver are external to the device. DC-coupled LVPECL is supported if the LVPECL output common mode voltage is in Cyclone IV devices LVPECL input buffer specification (refer to Figure 6–18). Figure 6–17. LVPECL AC-Coupled Termination (Note 1) LVPECL Transmitter Cyclone IV Device LVPECL Receiver 0.1 µF Z0 = 50 Ω Z0 = 50 Ω VICM 50 Ω 50 Ω 0.1 µF Note to Figure 6–17: (1) The LVPECL AC/DC-coupled termination is applicable only when an Altera FPGA transmitter is used. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Standards Support 6–29 Figure 6–18 shows the LVPECL DC-coupled termination. Figure 6–18. LVPECL DC-Coupled Termination Cyclone IV Device LVPECL Receiver LVPECL Transmitter 50 Ω 100 Ω 50 Ω Differential SSTL I/O Standard Support in Cyclone IV Devices The differential SSTL I/O standard is a memory-bus standard used for applications such as high-speed DDR SDRAM interfaces. Cyclone IV devices support differential SSTL-2 and SSTL-18 I/O standards. The differential SSTL I/O standard requires two differential inputs with an external reference voltage (VREF) as well as an external termination voltage (VTT) of 0.5 × VCCIO to which termination resistors are connected. The differential SSTL output standard is only supported at PLL#_CLKOUT pins using two single-ended SSTL output buffers (PLL#_CLKOUTp and PLL#_CLKOUTn), with the second output programmed to have opposite polarity. The differential SSTL input standard is supported on the GCLK pins only, treating differential inputs as two single-ended SSTL and only decoding one of them. f For differential SSTL electrical specifications, refer to “Differential I/O Standard Termination” on page 6–14 and the Cyclone IV Device Data Sheet chapter in volume 3. Figure 6–8 on page 6–15 shows the differential SSTL Class I and Class II interface. Differential HSTL I/O Standard Support in Cyclone IV Devices The differential HSTL I/O standard is used for the applications designed to operate in 0 V to 1.2 V, 0 V to 1.5 V, or 0 V to 1.8 V HSTL logic switching range. Cyclone IV devices support differential HSTL-18, HSTL-15, and HSTL-12 I/O standards. The differential HSTL input standard is available on GCLK pins only, treating the differential inputs as two single-ended HSTL and only decoding one of them. The differential HSTL output standard is only supported at the PLL#_CLKOUT pins using two single-ended HSTL output buffers (PLL#_CLKOUTp and PLL#_CLKOUTn), with the second output programmed to have opposite polarity. The standard requires two differential inputs with an external reference voltage (VREF), as well as an external termination voltage (VTT) of 0.5 × VCCIO to which termination resistors are connected. f For differential HSTL signaling characteristics, refer to “Differential I/O Standard Termination” on page 6–14 and the Cyclone IV Device Data Sheet chapter in volume 3. Figure 6–7 on page 6–14 shows the differential HSTL Class I and Class II interface. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 6–30 Chapter 6: I/O Features in Cyclone IV Devices True Output Buffer Feature True Output Buffer Feature Cyclone IV devices true differential transmitters offer programmable pre-emphasis— you can choose to turn it on or off. The default setting is on. Programmable Pre-Emphasis The programmable pre-emphasis boosts the high frequencies of the output signal to compensate the frequency-dependant attenuation of the transmission line to maximize the data eye opening at the far-end receiver. Without pre-emphasis, the output current is limited by the VOD specification and the output impedance of the transmitter. At high frequency, the slew rate may not be fast enough to reach full VOD before the next edge; this may lead to pattern dependent jitter. With pre-emphasis, the output current is momentarily boosted during switching to increase the output slew rate. The overshoot produced by this extra switching current is different from the overshoot caused by signal reflection. This overshoot happens only during switching, and does not produce ringing. The Quartus II software allows two settings for programmable pre-emphasis control—0 and 1, in which 0 is pre-emphasis off and 1 is pre-emphasis on. The default setting is 1. The amount of pre-emphasis needed depends on the amplification of the high-frequency components along the transmission line. You must adjust the setting to suit your designs, as pre-emphasis decreases the amplitude of the low-frequency component of the output signal. Figure 6–19 shows the differential output signal with pre-emphasis. Figure 6–19. The Output Signal with Pre-Emphasis Overshoot Positive channel (p) VOD Negative channel (n) Undershoot Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices High-Speed I/O Timing 6–31 High-Speed I/O Timing This section discusses the timing budget, waveforms, and specifications for source-synchronous signaling in Cyclone IV devices. Timing for source-synchronous signaling is based on skew between the data and clock signals. High-speed differential data transmission requires timing parameters provided by IC vendors and requires you to consider the board skew, cable skew, and clock jitter. This section provides information about high-speed I/O standards timing parameters in Cyclone IV devices. Table 6–8 defines the parameters of the timing diagram shown in Figure 6–20. Table 6–8. High-Speed I/O Timing Definitions Parameter Symbol Description Transmitter channel-to-channel skew (1) TCCS The timing difference between the fastest and slowest output edges, including tCO variation and clock skew. The clock is included in the TCCS measurement. Sampling window SW The period of time during which the data must be valid in order for you to capture it correctly. The setup and hold times determine the ideal strobe position in the sampling window. TSW = TSU + Thd + PLL jitter. Receiver input skew margin RSKM RSKM is defined by the total margin left after accounting for the sampling window and TCCS. The RSKM equation is: ( TUI – SW – TCCS ) RSKM = ---------------------------------------------2 Input jitter tolerance (peak-to-peak) — Allowed input jitter on the input clock to the PLL that is tolerable while maintaining PLL lock. Output jitter (peak-to-peak) — Peak-to-peak output jitter from the PLL. Note to Table 6–8: (1) The TCCS specification applies to the entire bank of differential I/O as long as the SERDES logic is placed in the logic array block (LAB) adjacent to the output pins. Figure 6–20. High-Speed I/O Timing Diagram External Input Clock Time Unit Interval (TUI) Internal Clock Receiver Input Data © November 2009 Altera Corporation TCCS RSKM RSKM TCCS Sampling Window (SW) Cyclone IV Device Handbook, Volume 1 6–32 Chapter 6: I/O Features in Cyclone IV Devices Design Guidelines Figure 6–21 shows Cyclone IV devices high-speed I/O timing budget. Figure 6–21. Cyclone IV Devices High-Speed I/O Timing Budget (Note 1) Internal Clock Period 0.5 × TCCS RSKM SW RSKM 0.5 × TCCS Note to Figure 6–21: (1) The equation for the high-speed I/O timing budget is: Period = 0.5 × TCCS + RSKM + SW + RSKM + 0.5 × TCCS. f For more information, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Design Guidelines This section provides guidelines for designing with Cyclone IV devices. Differential Pad Placement Guidelines To maintain an acceptable noise level on the VCCIO supply, you must observe some restrictions on the placement of single-ended I/O pins in relation to differential pads. f For guidelines on placing single-ended pads with respect to differential pads in Cyclone IV devices, refer to the “Pad Placement and DC Guidelines” on page 6–20. Board Design Considerations This section explains how to achieve the optimal performance from a Cyclone IV I/O interface and ensure first-time success in implementing a functional design with optimal signal quality. You must consider the critical issues of controlled impedance of traces and connectors, differential routing, and termination techniques to get the best performance from Cyclone IV devices. Use the following general guidelines for improved signal quality: ■ Base board designs on controlled differential impedance. Calculate and compare all parameters, such as trace width, trace thickness, and the distance between two differential traces. ■ Maintain equal distance between traces in differential I/O standard pairs as much as possible. Routing the pair of traces close to each other maximizes the common-mode rejection ratio (CMRR). ■ Longer traces have more inductance and capacitance. These traces must be as short as possible to limit signal integrity issues. ■ Place termination resistors as close to receiver input pins as possible. ■ Use surface mount components. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 6: I/O Features in Cyclone IV Devices Software Overview f 6–33 ■ Avoid 90° corners on board traces. ■ Use high-performance connectors. ■ Design backplane and card traces so that trace impedance matches the impedance of the connector and termination. ■ Keep an equal number of vias for both signal traces. ■ Create equal trace lengths to avoid skew between signals. Unequal trace lengths result in misplaced crossing points and decrease system margins as the transmitter-channel-to-channel skew (TCCS) value increases. ■ Limit vias because they cause discontinuities. ■ Keep switching transistor-to-transistor logic (TTL) signals away from differential signals to avoid possible noise coupling. ■ Do not route TTL clock signals to areas under or above the differential signals. ■ Analyze system-level signals. For PCB layout guidelines, refer to AN 224: High-Speed Board Layout Guidelines and AN 315: Guidelines for Designing High-Speed FPGA PCBs. Software Overview Cyclone IV devices high-speed I/O system interfaces are created in core logic by a Quartus II software megafunction because they do not have a dedicated circuit for the SERDES. Cyclone IV devices use the I/O registers and LE registers to improve the timing performance and support the SERDES. The Quartus II software allows you to design your high-speed interfaces using ALTLVDS megafunction. This megafunction implements either a high-speed deserializer receiver or a high-speed serializer transmitter. There is a list of parameters in the ALTLVDS megafunction that you can set to customize your SERDES based on your design requirements. The megafunction is optimized to use Cyclone IV devices resources to create high-speed I/O interfaces in the most effective manner. 1 f © November 2009 When you are using Cyclone IV devices with the ALTLVDS megafunction, the interface always sends the MSB of your parallel data first. For more details about designing your high-speed I/O systems interfaces using the ALTLVDS megafunction, refer to the ALTLVDS Megafunction User Guide and the Quartus II Handbook. Altera Corporation Cyclone IV Device Handbook, Volume 1 6–34 Chapter 6: I/O Features in Cyclone IV Devices Chapter Revision History Chapter Revision History Table 6–9 lists the revision history for this chapter. Table 6–9. Chapter Revision History Date Version November 2009 1.0 Cyclone IV Device Handbook, Volume 1 Changes Made Initial release. © November 2009 Altera Corporation 7. External Memory Interfaces in Cyclone IV Devices CYIV-51007-1.0 This chapter describes the memory interface pin support and the external memory interface features of Cyclone® IV devices. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. In addition to an abundant supply of on-chip memory, Cyclone IV devices can easily interface with a broad range of external memory devices, including DDR2 SDRAM, DDR SDRAM, and QDR II SRAM. External memory devices are an important system component of a wide range of image processing, storage, communications, and general embedded applications. 1 Altera recommends that you construct all DDR2 or DDR SDRAM external memory interfaces using the Altera® ALTMEMPHY megafunction. You can implement the controller function using the Altera DDR2 or DDR SDRAM memory controllers, third-party controllers, or a custom controller for unique application needs. Cyclone IV devices support QDR II interfaces electrically, but Altera does not supply controller or physical layer (PHY) megafunctions for QDR II interfaces. This chapter includes the following sections: f © November 2009 ■ “Cyclone IV Devices Memory Interfaces Pin Support” on page 7–2 ■ “Cyclone IV Devices Memory Interfaces Features” on page 7–8 For more information about supported maximum clock rate, device and pin planning, IP implementation, and device termination, refer to the External Memory Interface Handbook. Altera Corporation Cyclone IV Device Handbook, Volume 1 7–2 Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support Figure 7–1 shows the block diagram of a typical external memory interface data path in Cyclone IV devices. Figure 7–1. Cyclone IV Devices External Memory Data Path (Note 1) DQS/CQ/CQn OE IOE Register OE IOE Register DQ IOE Register IOE Register VCC IOE Register DataA IOE Register LE Register GND IOE Register DataB IOE Register LE Register LE Register System Clock PLL -90° Shifted Clock Capture Clock Note to Figure 7–1: (1) All clocks shown here are global clocks. f For more information about implementing complete external memory interfaces, refer to the External Memory Interface Handbook. Cyclone IV Devices Memory Interfaces Pin Support Cyclone IV devices use data (DQ), data strobe (DQS), clock, command, and address pins to interface with external memory. Some memory interfaces use the data mask (DM) or byte write select (BWS#) pins to enable data masking. This section describes how Cyclone IV devices support all these different pins. f For more information about pin utilization, refer to Volume 2: Device, Pin, and Board Layout Guidelines of the External Memory Interface Handbook. Data and Data Clock/Strobe Pins Cyclone IV data pins for external memory interfaces are called D for write data, Q for read data, or DQ for shared read and write data pins. The read-data strobes or read clocks are called DQS pins. Cyclone IV devices support both bidirectional data strobes and unidirectional read clocks. Depending on the external memory standard, the DQ and DQS are bidirectional signals (in DDR2 and DDR SDRAM) or unidirectional signals (in QDR II SRAM). Connect the bidirectional DQ data signals to the same Cyclone IV devices DQ pins. For unidirectional D or Q signals, connect the read-data signals to a group of DQ pins and the write-data signals to a different group of DQ pins. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support 1 7–3 In QDR II SRAM, the Q read-data group must be placed at a different VREF bank location from the D write-data group, command, or address pins. In Cyclone IV devices, DQS is used only during write mode in DDR2 and DDR SDRAM interfaces. Cyclone IV devices ignore DQS as the read-data strobe because the PHY internally generates the read capture clock for read mode. However, you must connect the DQS pin to the DQS signal in DDR2 and DDR SDRAM interfaces, or to the CQ signal in QDR II SRAM interfaces. 1 f 1 Cyclone IV devices do not support differential strobe pins, which is an optional feature in the DDR2 SDRAM device. When you use the Altera Memory Controller MegaCore ® function, the PHY is instantiated for you. For more information about the memory interface data path, refer to the External Memory Interface Handbook. ALTMEMPHY is a self-calibrating megafunction, enhanced to simplify the implementation of the read-data path in different memory interfaces. The auto-calibration feature of ALTMEMPHY provides ease-of-use by optimizing clock phases and frequencies across process, voltage, and temperature (PVT) variations. You can save on the global clock resources in Cyclone IV devices through the ALTMEMPHY megafunction because you are not required to route the DQS signals on the global clock buses (because DQS is ignored for read capture). Resynchronization issues do not arise because no transfer occurs from the memory domain clock (DQS) to the system domain for capturing data DQ. All I/O banks in Cyclone IV devices can support DQ and DQS signals with DQ-bus modes of ×8, ×9, ×16, ×18, ×32, and ×36 except Cyclone IV GX devices that do not support left I/O bank interface. DDR2 and DDR SDRAM interfaces use ×8 mode DQS group regardless of the interface width. For a wider interface, you can use multiple ×8 DQ groups to achieve the desired width requirement. In the ×9, ×18, and ×36 modes, a pair of complementary DQS pins (CQ and CQ#) drives up to 9, 18, or 36 DQ pins, respectively, in the group, to support one, two, or four parity bits and the corresponding data bits. The ×9, ×18, and ×36 modes support the QDR II memory interface. CQ# is the inverted read-clock signal that is connected to the complementary data strobe (DQS or CQ#) pin. You can use any unused DQ pins as regular user I/O pins if they are not used as memory interface signals. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 7–4 Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support Table 7–1 lists the number of DQS or DQ groups supported on each side of the Cyclone IV device. Table 7–1. Cyclone IV Device DQS and DQ Bus Mode Support for Each Side of the Device (Note 1) Device EP4CGX15 148-pin QFN 169-pin FBGA EP4CGX22 169-pin FBGA EP4CGX30 324-pin FBGA EP4CGX50 484-pin FBGA EP4CGX75 672-pin FBGA EP4CGX110 Number ×8 Groups Number ×9 Groups Number ×16 Groups Number ×18 Groups Number ×32 Groups Number ×36 Groups Right 1 0 0 0 — — Top (2) 1 0 0 0 — — Bottom (3) 1 0 0 0 — — Right 1 0 0 0 — — Top (2) 1 0 0 0 — — Bottom (3) 1 0 0 0 — — Right 1 0 0 0 — — Top (2) 1 0 0 0 — — Bottom (3) 1 0 0 0 — — Right 2 2 1 1 — — Top 2 2 1 1 — — Bottom 2 2 1 1 — — Right 4 2 2 2 1 1 Top 4 2 2 2 1 1 Bottom 4 2 2 2 1 1 Package 484-pin FBGA EP4CGX150 672-pin FBGA 896-pin FBGA Side Right 4 2 2 2 1 1 Top 4 2 2 2 1 1 Bottom 4 2 2 2 1 1 Right 4 2 2 2 1 1 Top 4 2 2 2 1 1 Bottom 4 2 2 2 1 1 Right 4 2 2 2 1 1 Top 4 2 2 2 1 1 Bottom 4 2 2 2 1 1 Right 6 2 2 2 1 1 Top 6 2 3 3 1 1 Bottom 6 2 3 3 1 1 Notes to Table 7–1: (1) The number of the DQS/DQ group is still preliminary. (2) Some of the DQ pins can be used as RUP and RDN pins. You cannot use these groups if you are using these pins as RUP and RDN pins for OCT calibration. (3) Some of the DQ pins can be used as RUP pins while the DM pins can be used as RDN pins. You cannot use these groups if you are using the RUP and RDN pins for OCT calibration. f For more information about device package outline, refer to the Device Packaging Specifications webpage. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support 7–5 DQS pins are listed in the Cyclone IV pin tables as DQSXY, in which X indicates the DQS grouping number and Y indicates whether the group is located on the top (T), bottom (B), or right (R) side of the device. Similarly, the corresponding DQ pins are marked as DQXY, in which the X denotes the DQ grouping number and Y denotes whether the group is located on the top (T), bottom (B), or right (R) side of the device. For example, DQS2T indicates a DQS pin belonging to group 2, located on the top side of the device. Similarly, the DQ pins belonging to that group is shown as DQ2T. 1 Each DQ group is associated with its corresponding DQS pins, as defined in the Cyclone IV pin tables. For example: ■ For DDR2 or DDR SDRAM, ×8 DQ group DQ3B[7..0] pins are associated with the DQS3B pin (same 3B group index) ■ For QDR II SRAM, ×9 Q read-data group DQ3T[8..0] pins are associated with DQS0T/CQ0T and DQS1T/CQ0T# pins (same 0T group index) The Quartus® II software issues an error message if a DQ group is not placed properly with its associated DQS. Figure 7–2 shows the location and numbering of the DQS, DQ, or CQ# pins in the Cyclone IV I/O banks. I/O Bank 8B I/O Bank 8 I/O Bank 8A DQS0T/CQ1T DQS2T/CQ3T DQS4T/CQ5T DQS5T/CQ5T# (Note 1) I/O Bank 7 Transceiver Block (QL1) I/O Bank 9 DQS3T/CQ3T# DQS1T/CQ1T# Figure 7–2. DQS, CQ, or CQ# Pins in Cyclone IV I/O Banks I/O Bank 6 DQS4R/CQ5R DQS2R/CQ3R DQS0R/CQ1R Transceiver Block (QL0) Cyclone IV Device I/O Bank 5 DQS1R/CQ1R# DQS3R/CQ3R# DQS5R/CQ5R# DQS0B/CQ1B DQS2B/CQ3B I/O Bank 4 DQS4B/CQ5B I/O Bank 3A DQS5B/CQ5B# DQS3B/CQ3B# I/O Bank 3 DQS1B/CQ1B# I/O Bank 3B Note to Figure 7–2: (1) The DQS, CQ, or CQ# pin locations in this diagram apply to all packages in Cyclone IV devices except devices in 148pin QFP, 169-pin FBGA, and 324-pin FBGA. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 7–6 Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support Figure 7–3 shows the location and numbering of the DQS, DQ, or CQ# pins in I/O banks of the Cyclone IV device in the 324-pin FBGA package only. DQS0T/CQ0T DQS2T/CQ1T I/O Bank 7 I/O Bank 6 I/O Bank 8A DQS2R/CQ1R I/O Bank 5 I/O Bank 8 Transceiver Block (QL1) I/O Bank 9 DQS3T/CQ1T# DQS1T/CQ0T# Figure 7–3. DQS, CQ, or CQ# Pins for Devices in the 324-Pin FBGA Package DQS1R/CQ0R# DQS0R/CQ0R Cyclone IV Device 324-pin FBGA Package DQS0B/CQ0B I/O Bank 4 DQS2B/CQ1B I/O Bank 3A DQS3B/CQ1B# DQS1B/CQ0B# I/O Bank 3 DQS3R/CQ1R# Figure 7–4 shows the location and numbering of the DQS, DQ, or CQ# pins in I/O banks of the Cyclone IV device in the 148-pin QFP and 169-pin FBGA packages only. I/O Bank 7 I/O Bank 6 I/O Bank 8A DQS0R/CQ0R DQS1R/CQ0R# Cyclone IV Device 148- and 169-pin FBGA Packages I/O Bank 3A I/O Bank 4 DQS0B/CQ0B DQS1B/CQ0B# I/O Bank 3 Cyclone IV Device Handbook, Volume 1 I/O Bank 8 I/O Bank 5 Transceiver Block (QL1) I/O Bank 9 DQS0T/CQ0T DQS1T/CQ0T# Figure 7–4. DQS, CQ, or CQ# Pins for Devices in the 148-Pin QFP and 169-Pin FBGA Packages © November 2009 Altera Corporation Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Pin Support 7–7 In Cyclone IV devices, the ×9 mode uses the same DQ and DQS pins as the ×8 mode, and one additional DQ pin that serves as a regular I/O pin in the ×8 mode. The ×18 mode uses the same DQ and DQS pins as ×16 mode, with two additional DQ pins that serve as regular I/O pins in the ×16 mode. Similarly, the ×36 mode uses the same DQ and DQS pins as the ×32 mode, with four additional DQ pins that serve as regular I/O pins in the ×32 mode. When not used as DQ or DQS pins, the memory interface pins are available as regular I/O pins. Optional Parity, DM, and Error Correction Coding Pins Cyclone IV devices support parity in ×9, ×18, and ×36 modes. One parity bit is available per eight bits of data pins. You can use any of the DQ pins for parity in Cyclone IV devices because the parity pins are treated and configured similarly to DQ pins. DM pins are only required when writing to DDR2 and DDR SDRAM devices. QDR II SRAM devices use the BWS# signal to select the byte to be written into memory. A low signal on the DM or BWS# pin indicates the write is valid. Driving the DM or BWS# pin high causes the memory to mask the DQ signals. Each group of DQS and DQ signals has one DM pin. Similar to the DQ output signals, the DM signals are clocked by the -90° shifted clock. In Cyclone IV devices, the DM pins are preassigned in the device pinouts. The Quartus II Fitter treats the DQ and DM pins in a DQS group equally for placement purposes. The preassigned DQ and DM pins are the preferred pins to use. Some DDR2 SDRAM and DDR SDRAM devices support error correction coding (ECC), a method of detecting and automatically correcting errors in data transmission. In 72-bit DDR2 or DDR SDRAM, there are eight ECC pins and 64 data pins. Connect the DDR2 and DDR SDRAM ECC pins to a separate DQS or DQ group in Cyclone IV devices. The memory controller needs additional logic to encode and decode the ECC data. Address and Control/Command Pins The address signals and the control or command signals are typically sent at a single data rate. You can use any of the user I/O pins on all I/O banks of Cyclone IV devices to generate the address and control or command signals to the memory device. 1 Cyclone IV devices do not support QDR II SRAM in the burst length of two. Memory Clock Pins In DDR2 and DDR SDRAM memory interfaces, the memory clock signals (CK and CK#) are used to capture the address signals and the control or command signals. Similarly, QDR II SRAM devices use the write clocks (K and K#) to capture the address and command signals. The CK/CK# and K/K# signals are generated to resemble the write-data strobe using the DDIO registers in Cyclone IV devices. 1 © November 2009 CK/CK# pins must be placed on differential I/O pins (DIFFIO in Pin Planner) and in the same bank or on the same side as the data pins. You can use either side of the device for wraparound interfaces. As seen in the Pin Planner Pad View, CK0 cannot be located in the same row and column pad group as any of the interfacing DQ pins. Altera Corporation Cyclone IV Device Handbook, Volume 1 7–8 Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Features f For more information about memory clock pin placement, refer to Volume 2: Device, Pin, and Board Layout Guidelines of the External Memory Interface Handbook. Cyclone IV Devices Memory Interfaces Features This section discusses Cyclone IV memory interfaces, including DDR input registers, DDR output registers, OCT, and phase-lock loops (PLLs). DDR Input Registers The DDR input registers are implemented with three internal logic element (LE) registers for every DQ pin. These LE registers are located in the logic array block (LAB) adjacent to the DDR input pin. Figure 7–5 illustrates Cyclone IV DDR input registers. Figure 7–5. Cyclone IV DDR Input Registers DDR Input Registers in Cyclone IV Device DQ LE Register dataout_h Input Register A I neg_reg_out dataout_l LE Register LE Register Register C I Input Register B I Capture Clock PLL These DDR input registers are implemented in the core of devices. The DDR data is first fed to two registers, input register AI and input register B I. ■ Input register AI captures the DDR data present during the rising edge of the clock ■ Input register B I captures the DDR data present during the falling edge of the clock ■ Register CI aligns the data before it is synchronized with the system clock The data from the DDR input register is fed to two registers, sync_reg_h and sync_reg_l, then the data is typically transferred to a FIFO block to synchronize the two data streams to the rising edge of the system clock. Because the read-capture clock is generated by the PLL, the read-data strobe signal (DQS or CQ) is not used during read operation in Cyclone IV devices; hence, postamble is not a concern in this case. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Features 7–9 DDR Output Registers A dedicated write DDIO block is implemented in the DDR output and output enable paths. Figure 7–6 shows how a Cyclone IV dedicated write DDIO block is implemented in the I/O element (IOE) registers. Figure 7–6. Cyclone IV Dedicated Write DDIO DDR Output Enable Registers Output Enable IOE Register Output Enable Register AOE data1 data0 IOE Register Output Enable Register BOE DDR Output Registers datain_l IOE Register data0 Output Register AO DQ or DQS data1 datain_h IOE Register -90° Shifted Clock ® Output Register BO The two DDR output registers are located in the I/O element (IOE) block. Two serial data streams routed through datain_l and datain_h, are fed into two registers, output register Ao and output register Bo, respectively, on the same clock edge. The output from output register Ao is captured on the falling edge of the clock, while the output from output register Bo is captured on the rising edge of the clock. The registered outputs are multiplexed by the common clock to drive the DDR output pin at twice the data rate. The DDR output enable path has a similar structure to the DDR output path in the IOE block. The second output enable register provides the write preamble for the DQS strobe in DDR external memory interfaces. This active-low output enable register extends the high-impedance state of the pin by half a clock cycle to provide the external memory’s DQS write preamble time specification. f © November 2009 For more information about Cyclone IV IOE registers, refer to the Cyclone IV Device I/O Features chapter in volume 1. Altera Corporation Cyclone IV Device Handbook, Volume 1 7–10 Chapter 7: External Memory Interfaces in Cyclone IV Devices Cyclone IV Devices Memory Interfaces Features Figure 7–7 illustrates how the second output enable register extends the DQS high-impedance state by half a clock cycle during a write operation. Figure 7–7. Extending the OE Disable by Half a Clock Cycle for a Write Transaction (Note 1) System clock (outclock for DQS) OE for DQS (from logic array) DQS Write Clock (outclock for DQ, o -90 phase shifted from System Clock) datain_h (from logic array) datain_I (from logic array) 90 o Delay by Half a Clock Cycle Preamble Postamble D0 D2 D1 D3 OE for DQ (from logic array) DQ D0 D1 D2 D3 Note to Figure 7–7: (1) The waveform reflects the software simulation result. The OE signal is an active low on the device. However, the Quartus II software implements the signal as an active high and automatically adds an inverter before the AOE register D input. OCT with Calibration Cyclone IV devices support calibrated on-chip series termination (R S OCT) in both vertical and horizontal I/O banks. To use the calibrated OCT, you must use the RUP and RDN pins for each R S OCT control block (one for each side). You can use each OCT calibration block to calibrate one type of termination with the same V CCIO for that given side. f For more information about the Cyclone IV devices OCT calibration block, refer to the Cyclone IV Device I/O Features chapter in volume 1. PLL When interfacing with external memory, the PLL is used to generate the memory system clock, the write clock, the capture clock and the logic-core clock. The system clock generates the DQS write signals, commands, and addresses. The write-clock is shifted by -90° from the system clock and generates the DQ signals during writes. You can use the PLL reconfiguration feature to calibrate the read-capture phase shift to balance the setup and hold margins. 1 f The PLL is instantiated in the ALTMEMPHY megafunction. All outputs of the PLL are used when the ALTMEMPHY megafunction is instantiated to interface with external memories. For more information about usage of PLL outputs by the ALTMEMPHY megafunction, refer to the External Memory Interface Handbook. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 7: External Memory Interfaces in Cyclone IV Devices Chapter Revision History f 7–11 For more information about Cyclone IV PLL, refer to the Clock Networks and PLLs in Cyclone IV Devices chapter in volume 1. Chapter Revision History Table 7–2 lists the revision history for this chapter. Table 7–2. Chapter Revision History Date Version November 2009 1.0 © November 2009 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 1 7–12 Cyclone IV Device Handbook, Volume 1 Chapter 7: External Memory Interfaces in Cyclone IV Devices Chapter Revision History © November 2009 Altera Corporation Section 3. System Integration This section includes the following chapters: ■ Chapter 8, Configuration and Remote System Upgrades in Cyclone IV Devices ■ Chapter 9, SEU Mitigation in Cyclone IV Devices ■ Chapter 10, JTAG Boundary-Scan Testing for Cyclone IV Devices ■ Chapter 11, Power Requirements for Cyclone IV Devices Revision History Refer to each chapter for its own specific revision history. For information on when each chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8. Configuration and Remote System Upgrades in Cyclone IV Devices CYIV-51008-1.0 Cyclone® IV devices use SRAM cells to store configuration data. Configuration data must be downloaded to Cyclone IV devices each time the device powers up because SRAM memory is volatile. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. Cyclone IV devices are configured using one of the following configuration schemes: 1 ■ Active serial (AS) ■ Passive serial (PS) ■ Fast passive parallel (FPP) ■ Joint Test Action Group (JTAG) FPP configuration scheme is only supported in EP4CGX50, EP4CGX75, EP4CGX110 and EP4CGX150 devices. Cyclone IV devices offer the following configuration features: ■ Configuration data decompression (“Configuration Data Decompression” on page 8–2) ■ Remote system upgrade (“Remote System Upgrade” on page 8–51) System designers face difficult challenges, such as shortened design cycles, evolving standards, and system deployments in remote locations. Cyclone IV devices help overcome these challenges with inherent re-programmability and dedicated circuitry to perform remote system upgrades. Remote system upgrades help deliver feature enhancements and bug fixes without costly recalls, reduced time-to-market, and extended product life. Configuration This section describes Cyclone IV device configuration and includes the following topics: ■ “Configuration Features” on page 8–2 ■ “Configuration Requirement” on page 8–3 ■ “Configuration Process” on page 8–5 ■ “Configuration Scheme” on page 8–7 ■ “AS Configuration (Serial Configuration Devices)” on page 8–8 ■ “PS Configuration” on page 8–18 ■ “FPP Configuration” on page 8–26 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–2 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration ■ “JTAG Configuration” on page 8–31 ■ “Device Configuration Pins” on page 8–46 Configuration Features Table 8–1 summarizes the configuration methods you can use in each configuration scheme. Table 8–1. Cyclone IV Device Configuration Features Configuration Scheme Active Serial Passive Serial Fast Passive Parallel JTAG based configuration Decompression Remote System Upgrade (1) Serial Configuration Device v v External Host with Flash Memory v — Download Cable v — External Host with Flash Memory — — External Host with Flash Memory — — Download Cable — — Configuration Method Note to Table 8–1: (1) Remote update mode is supported when you use the remote system upgrade feature. You can enable or disable the remote update mode with an option setting in the Quartus ® II software. Configuration Data Decompression Cyclone IV devices support configuration data decompression, which saves configuration memory space and time. This feature allows you to store compressed configuration data in configuration devices or other memory, and send the compressed bitstream to Cyclone IV devices. During configuration, Cyclone IV devices decompress the bitstream in real time and program the SRAM cells. 1 Preliminary data indicates that compression reduces configuration bitstream size by 35 to 55%. When you enable compression, the Quartus II software generates configuration files with compressed configuration data. This compressed file reduces the storage requirements in the configuration device or flash memory and decreases the time required to send the bitstream to the Cyclone IV device. The time required by a Cyclone IV device to decompress a configuration file is less than the time required to send the configuration data to the device. There are two methods for enabling compression for Cyclone IV device bitstreams in the Quartus II software: ■ Before design compilation (through the Compiler Settings menu). ■ After design compilation (through the Convert Programming Files dialog box). To enable compression in the compiler settings of the project, perform the following steps in the Quartus II software: 1. On the Assignments menu, click Device. The Settings dialog box appears. 2. Click Device and Pin Options. The Device and Pin Options dialog box appears. 3. Click the Configuration tab. 4. Turn on Generate compressed bitstreams. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–3 5. Click OK. 6. In the Settings dialog box, click OK. Compression can also be enabled when creating programming files from the Convert Programming Files dialog box. 1. On the File menu, click Convert Programming Files. 2. Under Output programming file, select your desired file type from the Programming file type list. 3. If you select Programmer Object File (.pof), you must specify the configuration device in the Configuration device list. 4. Under Input files to convert, select SOF Data. 5. Click Add File to browse to the Cyclone IV device .sof files. 6. In the Convert Programming Files dialog box, select the .pof you added to SOF Data and click Properties. 7. In the SOF File Properties dialog box, turn on the Compression option. When multiple Cyclone IV devices are cascaded, you can selectively enable the compression feature for each device in the chain. Figure 8–1 shows a chain of two Cyclone IV devices. The first device has compression enabled and receives compressed bitstream from the configuration device. The second device has the compression feature disabled and receives uncompressed data. You can generate programming files for this setup in the Convert Programming Files dialog box. Figure 8–1. Compressed and Uncompressed Configuration Data in the Same Configuration File Serial Data Serial Configuration Device Compressed Decompression Controller 10 kΩ Cyclone IV Device Family nCE Uncompressed VCC nCEO Decompression Controller Cyclone IV Device Family nCE nCEO Not Connected (N.C.) GND Configuration Requirement Power-On Reset (POR) Circuit The POR circuit keeps the device in reset state until the power supply voltage levels have stabilized during device power-up. After device power-up, the device does not release nSTATUS until VCCINT, VCCA , VCCIO are above the POR trip point of the device. VCCINT and VCCA are monitored for brown-out conditions upon device power-up. 1 VCCA is the analog power to the PLL. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–4 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration In Cyclone IV devices, you can select either a fast POR time or a standard POR time, depending on the MSEL pin settings. f For more information about the POR specifications, refer to the Cyclone IV Device Data Sheet. In some applications, it is necessary for a device to wake up very quickly to begin operation. Cyclone IV devices offer the fast POR time option to support fast wake-up time applications. The fast POR time option has stricter power-up requirements compared to the standard POR time option. You can select either the fast POR option or the standard POR option with the MSEL pin settings. f For more information on wake-up time and POR circuit, refer to the Power Requirements for Cyclone IV Devices chapter in volume 1 of the Cyclone IV Device Handbook. Configuration File Size Table 8–2 shows the approximate uncompressed configuration file sizes for Cyclone IV devices. To calculate the amount of storage space required for multiple device configurations, add the file size of each device together. Table 8–2. Cyclone IV Device Uncompressed Raw Binary File (.rbf) Sizes (Note 1) Device Data Size (bits) EP4CGX15 3,805,570 EP4CGX22 7,600,042 EP4CGX30 7,600,042 EP4CGX50 24,500,000 EP4CGX75 24,500,000 EP4CGX110 47,600,000 EP4CGX150 47,600,000 Note to Table 8–2: (1) These values are preliminary. Use the data in Table 8–2 to estimate the file size before design compilation. Different configuration file formats, such as Hexadecimal (.hex) or Tabular Text File (.ttf) formats, have different file sizes. However, for any specific version of the Quartus II software, any design targeted for the same device has the same uncompressed configuration file size. If you use compression, the file size varies after each compilation, because the compression ratio is dependent on the design. f For more information about setting device configuration options or creating configuration files, refer to the Software Settings section in volume 2 of the Configuration Handbook. Configuration and JTAG Pin I/O Requirements Cyclone IV devices are manufactured using the TSMC 60-nm low-k dielectric process. Although Cyclone IV devices use TSMC 2.5-V transistor technology in the I/O buffers, the devices are compatible and able to interface with 2.5/3.0/3.3-V configuration voltage standards by following specific requirements. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–5 All I/O inputs must maintain a maximum AC voltage of 4.1 V. When using a JTAG configuration scheme or a serial configuration device in an AS configuration scheme, you must connect a 25-Ω series resistor at the near end of the TDO and TDI pin or the serial configuration device for the DATA[0]pin. When cascading Cyclone IV devices in multi-device configuration, you must connect the repeater buffers between the master and slave devices for DATA and DCLK. The output resistance of the repeater buffers must fit the maximum overshoot equation shown in Equation 8–1: Equation 8–1. (Note 1) 0.8 Z O ≤R E ≤1.8Z O Note to Equation 8–1: (1) ZO is the transmission line impedance and RE is the equivalent resistance of the output buffer. Configuration Process This section describes the configuration process. Power Up If the device is powered up from the power-down state, the VCCINT, VCCA , and VCCIO for I/O banks 3, 8, and 9 must be powered up to the appropriate level for the device to exit from POR. Reset Upon power-up, Cyclone IV devices go through POR. The POR delay is dependent on the MSEL pin settings, which correspond to your configuration scheme. During POR, the device resets, holds nSTATUS and CONF_DONE low, and tri-states all user I/O pins. The user I/O pins and dual-purpose I/O pins have weak pull-up resistors, which are always enabled (after POR) before and during configuration. When the device exits POR, all user I/O pins continue to tri-state. While nCONFIG is low, the device is in reset. When nCONFIG goes high, the device exits reset and releases the open-drain nSTATUS pin, which is then pulled high by an external 10 kΩ pull-up resistor. After nSTATUS is released, the device is ready to receive configuration data and the configuration stage begins. f For more information about the value of the weak pull-up resistors on the I/O pins that are on before and during configuration, refer to the Cyclone IV Device Data Sheet chapter in volume 2 of the Cyclone IV Device Handbook. Configuration Configuration data is latched into the Cyclone IV device at each DCLK cycle. However, the width of the data bus and the configuration time taken for each scheme are different. After the device receives all configuration data, the device releases the open-drain CONF_DONE pin, which is pulled high by an external 10-kΩ pull-up resistor. A low-to-high transition on the CONF_DONE pin indicates that the configuration is complete and initialization of the device can begin. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–6 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration You can begin reconfiguration by pulling the nCONFIG pin low. The nCONFIG pin must be low for at least 500 ns. When nCONFIG is pulled low, the Cyclone IV device is reset. The Cyclone IV device also pulls nSTATUS and CONF_DONE low and all I/O pins are tri-stated. When nCONFIG returns to a logic-high level and nSTATUS is released by the Cyclone IV device, reconfiguration begins. Configuration Error If an error occurs during configuration, Cyclone IV devices assert the nSTATUS signal low, indicating a data frame error, and the CONF_DONE signal stays low. If the Auto-restart configuration after error option (available in the Quartus II software in the General tab of the Device and Pin Options dialog box) is turned on, the Cyclone IV device releases nSTATUS after a reset time-out period (maximum of 230 μs), and retries configuration. If this option is turned off, the system must monitor nSTATUS for errors and then pulse nCONFIG low for at least 500 ns to restart configuration. Initialization In Cyclone IV devices, the initialization clock source is either the internal oscillator or the optional CLKUSR pin.By default, the internal oscillator is the clock source for initialization. If the internal oscillator is used, the device provides itself with enough clock cycles for proper initialization. When using the internal oscillator, you do not have to send additional clock cycles from an external source to the CLKUSR pin during the initialization stage. Additionally, you can use the CLKUSR pin as a user I/O pin. You also have the flexibility to synchronize initialization of multiple devices or to delay initialization with the CLKUSR option. The CLKUSR pin allows you to control when your device enters user mode for an indefinite amount of time. You can turn on the Enable user-supplied start-up clock (CLKUSR) option in the Quartus II software in the General tab of the Device and Pin Options dialog box. When you turn on the Enable user supplied start-up clock option (CLKUSR) option, the CLKUSR pin is the initialization clock source. Supplying a clock on the CLKUSR pin does not affect the configuration process. After the configuration data is accepted and CONF_DONE goes high, Cyclone IV devices require 3,187 clock cycles to initialize properly and enter user mode. 1 If you use the optional CLKUSR pin and the nCONFIG pin is pulled low to restart configuration during device initialization, ensure that the CLKUSR pin continues to toggle when nSTATUS is low (a maximum of 230 μs). User Mode An optional INIT_DONE pin is available, which signals the end of initialization and the start of user mode with a low-to-high transition. The Enable INIT_DONE Output option is available in the Quartus II software in the General tab of the Device and Pin Options dialog box. If the INIT_DONE pin is used, it will be high due to an external 10-kΩ pull-up resistor when nCONFIG is low and during the beginning of configuration. After the option bit to enable INIT_DONE is programmed into the device (during the first frame of configuration data), the INIT_DONE pin goes low. When initialization is complete, the INIT_DONE pin is released and pulled high. This low-to-high transition signals that the device has entered user mode. In user mode, the user I/O pins function as assigned in your design and no longer have weak pull-up resistors. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration f 8–7 For more information about the configuration cycle state machine of Altera® FPGAs, refer to the Configuring Altera FPGAs chapter in volume 1 of the Configuration Handbook. Configuration Scheme A configuration scheme with different configuration voltage standards is selected by driving the MSEL pins either high or low as shown in Table 8–3 and Table 8–4. The MSEL pins are powered by VCCINT. 1 Hardwire the MSEL pins to VCCA or GND without any pull-up or pull-down resistors to avoid any problems detecting an incorrect configuration scheme. Do not drive the MSEL pins with a microprocessor or another device. Table 8–3. Cyclone IV Device (EP4CGX15, EP4CGX22, and EP4CGX30) Configuration Schemes Configuration Scheme MSEL2 MSEL2 MSEL2 POR Delay Configuration Voltage Standard (V) (1) 1 0 1 Fast 3.3 0 1 1 Fast 3.0, 2.5 0 0 1 Standard 3.3 0 1 0 Standard 3.0, 2.5 1 0 0 Fast 3.3, 3.0, 2.5 1 1 0 Fast 1.8, 1.5 0 0 0 Standard 3.3, 3.0, 2.5 (3) (3) (3) — — Active Serial Standard (AS) Passive Serial (PS) JTAG based configuration (2) Notes to Table 8–3: (1) Configuration voltage standard applied to VCCIO supply of the bank in which the configuration pins reside. (2) JTAG-based configuration takes precedence over other configuration schemes, which means MSEL pin settings are ignored. (3) Do not leave the MSEL pins floating. Connect them to VCCA or GND. These pins support the non-JTAG configuration scheme used in production. Altera recommends connecting the MSEL pins to GND if your device is only using JTAG configuration. Table 8–4. Cyclone IV Device (EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150) Configuration Schemes (Part 1 of 2) Configuration Scheme Active Serial Standard (AS) Passive Serial (PS) Fast Passive Parallel (FPP) © November 2009 Altera Corporation MSEL3 MSEL2 MSEL2 MSEL2 POR Delay Configuration Voltage Standard (V) (1) 1 1 0 1 Fast 3.3 1 0 1 1 Fast 3.0, 2.5 1 0 0 1 Standard 3.3 1 0 1 0 Standard 3.0, 2.5 1 1 0 0 Fast 3.3, 3.0, 2.5 1 1 1 0 Fast 1.8, 1.5 1 0 0 0 Standard 3.3, 3.0, 2.5 0 0 0 0 Standard 1.8, 1.5 0 0 1 1 Fast 3.3, 3.0, 2.5 0 1 0 0 Fast 1.8, 1.5 0 0 0 1 Standard 3.3, 3.0, 2.5 0 0 1 0 Standard 1.8, 1.5 Cyclone IV Device Handbook, Volume 1 8–8 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–4. Cyclone IV Device (EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150) Configuration Schemes (Part 2 of 2) Configuration Scheme MSEL3 MSEL2 MSEL2 JTAG based configuration (2) (3) (3) (3) MSEL2 POR Delay Configuration Voltage Standard (V) (1) (3) — — Notes to Table 8–4: (1) Configuration voltage standard applied to VCCIO supply of the bank in which the configuration pins reside. (2) JTAG-based configuration takes precedence over other configuration schemes, which means MSEL pin settings are ignored. (3) Do not leave the MSEL pins floating. Connect them to VCCA or GND. These pins support the non-JTAG configuration scheme used in production. Altera recommends connecting the MSEL pins to GND if your device is only using JTAG configuration. AS Configuration (Serial Configuration Devices) In the AS configuration scheme, Cyclone IV devices are configured with a serial configuration device. These configuration devices are low-cost devices with non-volatile memories that feature a simple four-pin interface and a small form factor. These features make serial configuration devices the ideal low-cost configuration solution. f For more information about serial configuration devices, refer to the Serial Configuration Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet in the Configuration Handbook. Serial configuration devices provide a serial interface to access configuration data. During device configuration, Cyclone IV devices read configuration data through the serial interface, decompress data if necessary, and configure their SRAM cells. This scheme is referred to as the AS configuration scheme because the device controls the configuration interface. Single-Device AS Configuration The four-pin interface of serial configuration devices consists of the following pins: ■ Serial clock input (DCLK) ■ Serial data output (DATA) ■ AS data input (ASDI) ■ Active-low chip select (nCS) This four-pin interface connects to Cyclone IV device pins, as shown in Figure 8–2. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–9 Figure 8–2. Single-Device AS Configuration VCCIO (1) VCCIO (1) VCCIO (1) 10 kΩ 10 kΩ Serial Configuration Device 10 kΩ Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO N.C. (3) GND 25 Ω (5) DATA DCLK nCS ASDI (2) DATA[0] DCLK nCSO ASDO (6) MSEL[3..0] (4) Notes to Figure 8–2: (1) (2) (3) (4) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides. Cyclone IV devices use the ASDO -to-ASDI path to control the configuration device. The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (5) Connect the series resistor at the near end of the serial configuration device. (6) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. 1 The 25-Ω resistor at the near end of the serial configuration device for DATA[0] works to minimize the driver impedance mismatch with the board trace and reduce the overshoot seen at the Cyclone IV device DATA[0] input pin. In single-device AS configuration, the maximum board loading and board trace length between the supported serial configuration device and the Cyclone IV device must follow the recommendations in Table 8–5 on page 8–15. The DCLK generated by the Cyclone IV device controls the entire configuration cycle and provides timing for the serial interface. Cyclone IV devices use an internal oscillator or an external clock source to generate the DCLK. You can use a slow clock (20 MHz maximum) or a fast clock (40 MHz maximum) from the internal oscillator. There are some variations in the internal oscillator frequency because of the process, voltage, and temperature conditions in Cyclone IV devices. The internal oscillator is designed to ensure that its maximum frequency is guaranteed to meet EPCS device specifications. Cyclone IV devices offer the option to select CLKUSR (40 MHz maximum) as the external clock source for DCLK. You can change the clock source option in the Quartus II software in the Configuration tab of the Device and Pin Options dialog box. 1 EPCS1 does not support any Cyclone IV devices because of its insufficient memory capacity. 1 You must clock the CLKUSR pin at two times the expected DCLK frequency. The CLKUSR pin allows a maximum frequency of 80 MHz (40 MHz DCLK). © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–10 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration In configuration mode, the Cyclone IV device enables the serial configuration device by driving the nCSO output pin low, which connects to the nCS pin of the configuration device. The Cyclone IV device uses the DCLK and DATA[1]pins to send operation commands and read address signals to the serial configuration device. The configuration device provides data on its DATA pin, which connects to the DATA[0] input of the Cyclone IV device. All AS configuration pins (DATA[0], DCLK, nCSO, and DATA[1]) have weak internal pull-up resistors that are always active. After configuration, these pins are set as input tri-stated and are driven high by the weak internal pull-up resistors. The timing parameters for AS mode are not listed here, because the tCF2CD, tCF2ST0, tCFG, tSTATUS, tCF2ST1, and tCD2UM timing parameters are identical to the timing parameters for PS mode shown in Table 8–6 on page 8–22. Multi-Device AS Configuration You can configure multiple Cyclone IV devices with a single serial configuration device. When the first device captures all its configuration data from the bitstream, it drives the nCEO pin low, enabling the next device in the chain. You can leave the nCEO pin of the last device unconnected or use it as a user I/O pin after configuration if the last device in the chain is a Cyclone IV device. The nCONFIG, nSTATUS, CONF_DONE, DCLK, and DATA[0] pins of each device in the chain are connected together (refer to Figure 8–3). Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–11 Figure 8–3. Multi-device AS Configuration VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ VCCIO (1) VCCIO (2) 10 kΩ 10 kΩ Serial Configuration Device Master Device of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO Slave Device of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO N.C. (3) GND DATA DCLK nCS ASDI 25 Ω (5) 50 Ω (5), (7) DATA[0] DATA[0] DCLK DCLK nCSO ASDO (8) MSEL[3..0] (4) (8) MSEL[3..0] (4) 50 Ω (7) Buffers (6) Notes to Figure 8–3: (1) (2) (3) (4) (5) (6) (7) (8) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides. Connect the pull-up resistor to the VCCIO supply voltage of I/O bank in which the nCE pin resides. You can leave the nCEO pin unconnected or use it as a user I/O pin when it does not feed the nCE pin of another device. The MSEL pin settings vary for different configuration voltage standards and POR time. You must set the master device of the Cyclone IV device in AS mode and the slave devices in PS mode. To connect the MSEL pins for the master device in AS mode and slave devices in PS mode, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. Connect the series resistor at the near end of the serial configuration device. Connect the repeater buffers between the master and slave devices of the Cyclone IV device for DATA[0] and DCLK. All I/O inputs must maintain a maximum AC voltage of 4.1-V. The output resistance of the repeater buffers must fit the maximum overshoot equation outlined in “Configuration and JTAG Pin I/O Requirements” on page 8–4. The 50-Ω series resistors are optional if the 3.3-V configuration voltage standard is applied. For optimal signal integrity, connect these 50-Ω series resistors if the 2.5- or 3.0-V configuration voltage standard is applied. MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. The first Cyclone IV device in the chain is the configuration master and controls the configuration of the entire chain. Any other Altera device that supports PS configuration can also be part of the chain as a configuration slave. 1 In multi-device AS configuration, the board trace length between the serial configuration device to the master device of the Cyclone IV device must follow the recommendations in Table 8–5 on page 8–15. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–12 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration As shown in Figure 8–3 on page 8–11, the nSTATUS and CONF_DONE pins on all target devices are connected together with external pull-up resistors. These pins are open-drain bidirectional pins on the devices. When the first device asserts nCEO (after receiving all its configuration data), it releases its CONF_DONE pin. However, the subsequent devices in the chain keep this shared CONF_DONE line low until they receive their configuration data. When all target devices in the chain receive their configuration data and release CONF_DONE, the pull-up resistor drives a high level on this line and all devices simultaneously enter initialization mode. 1 Although you can cascade Cyclone IV devices, serial configuration devices cannot be cascaded or chained together. If the configuration bitstream size exceeds the capacity of a serial configuration device, you must select a larger configuration device, enable the compression feature, or both. When configuring multiple devices, the size of the bitstream is the sum of the individual device’s configuration bitstream. Configuring Multiple Cyclone IV Devices with the Same Design Certain designs require you to configure multiple Cyclone IV devices with the same design through a configuration bitstream, or a .sof. You can do this through the following methods: ■ Multiple .sof files ■ Single .sof 1 For both methods, the serial configuration devices cannot be cascaded or chained together. Multiple SRAM Object Files Two copies of the .sof are stored in the serial configuration device. Use the first copy to configure the master device of the Cyclone IV device and the second copy to configure all remaining slave devices concurrently. All slave devices must have the same density and package. The setup is similar to Figure 8–3 on page 8–11. To configure four identical Cyclone IV devices with the same .sof, you must set up the chain similar to the example shown in Figure 8–4 on page 8–13. The first device is the master device and its MSEL pins must be set to select AS configuration. The other three slave devices are set up for concurrent configuration and their MSEL pins must be set to select PS configuration. The nCEO pin from the master device drives the nCE input pins on all three slave devices, as well as the DATA and DCLK pins that connect in parallel to all four devices. During the first configuration cycle, the master device reads its configuration data from the serial configuration device while holding nCEO high. After completing its configuration cycle, the master device drives nCE low and sends the second copy of the configuration data to all three slave devices, configuring them simultaneously. The advantage of the setup in Figure 8–4 is that you can have a different .sof for the master device. However, all the slave devices must be configured with the same .sof. You can either compress or uncompress the .sof files in this configuration method. 1 You can still use this method if the master and slave devices use the same .sof. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–13 Figure 8–4. Multi-Device AS Configuration in which Devices Receive the Same Data with Multiple .sof Files VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ VCCIO (2) 10 kΩ Slave Device of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO N.C. (3) DATA[0] DCLK (8) MSEL[3..0] Master Device of the Cyclone IV Device Family Serial Configuration Device nSTATUS CONF_DONE nCONFIG nCE (4) Slave Device of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO nCEO N.C. (3) GND DATA DCLK nCS ASDI 25 Ω (5) 50 Ω (5), (7) DATA[0] DATA[0] DCLK DCLK nCSO ASDO (8) MSEL[3..0] (8) MSEL[3..0] (4) (4) Slave Device of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nCEO N.C. (3) 50 Ω (7) Buffers (6) DATA[0] DCLK (8) MSEL[3..0] (4) Notes to Figure 8–4: (1) (2) (3) (4) (5) (6) (7) (8) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides. Connect the pull-up resistor to the VCCIO supply voltage of the I/O bank in which the nCE pin resides. The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. The MSEL pin settings vary for different configuration voltage standards and POR time. You must set the master device in AS mode and the slave devices in PS mode. To connect the MSEL pins for the master device in AS mode and slave devices in PS mode, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. Connect the series resistor at the near end of the serial configuration device. Connect the repeater buffers between the master and slave devices for DATA[0] and DCLK. All I/O inputs must maintain a maximum AC voltage of 4.1 V. The output resistance of the repeater buffers must fit the maximum overshoot equation outlined in “Configuration and JTAG Pin I/O Requirements” on page 8–4. The 50-Ω series resistors are optional if the 3.3-V configuration voltage standard is applied. For optimal signal integrity, connect these 50-Ω series resistors if the 2.5-V or 3.0-V configuration voltage standard is applied. MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–14 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Single SRAM Object File The second method configures both the master device and slave devices with the same .sof. The serial configuration device stores one copy of the .sof. You must set up one or more slave devices in the chain. All the slave devices must be set up in the same way as shown in Figure 8–5. Figure 8–5. Multi-Device AS Configuration in Which Devices Receive the Same Data with a Single .sof VCCIO (1) 10 kΩ Serial Configuration Device VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ Master Device of the Cyclone IV Device Family Slave Device 1 of the Cyclone IV Device Family Slave Device 2 of the Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE nSTATUS CONF_DONE nCONFIG nCE nSTATUS CONF_DONE nCONFIG nCE nCEO N.C. (2) GND 25 Ω (4) DATA DCLK nCS ASDI 50 Ω (4),(6) nCEO N.C. (2) GND N.C. (2) DATA[0] DATA[0] DCLK nCSO ASDO nCEO GND DATA[0] DCLK (7) MSEL[3..0] (3) DCLK (7) MSEL[3..0] (3) (7) MSEL[3..0] (3) 50 Ω(7) Buffers (5) Notes to Figure 8–5: (1) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides. (2) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (3) The MSEL pin settings vary for different configuration voltage standards and POR time. You must set the master device of the Cyclone IV device in AS mode and the slave devices in PS mode. To connect the MSEL pins for the master device in AS mode and slave devices in PS mode, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (4) Connect the series resistor at the near end of the serial configuration device. (5) Connect the repeater buffers between the master and slave devices for DATA[0] and DCLK. All I/O inputs must maintain a maximum AC voltage of 4.1 V. The output resistance of the repeater buffers must fit the maximum overshoot equation outlined in “Configuration and JTAG Pin I/O Requirements” on page 8–4. (6) The 50-Ω series resistors are optional if the 3.3-V configuration voltage standard is applied. For optimal signal integrity, connect these 50-Ω series resistors if the 2.5-V or 3.0-V configuration voltage standard is applied. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. In this setup, all the Cyclone IV devices in the chain are connected for concurrent configuration. This can reduce the AS configuration time because all the Cyclone IV devices are configured in one configuration cycle. Connect the nCE input pins of all the Cyclone IV devices to GND. You can either leave the nCEO output pins on all the Cyclone IV devices unconnected or use the nCEO output pins as normal user I/O pins. The DATA and DCLK pins are connected in parallel to all the Cyclone IV devices. Altera recommends putting a buffer before the DATA and DCLK output from the master device to avoid signal strength and signal integrity issues. The buffer must not significantly change the DATA-to-DCLK relationships or delay them with respect to other AS signals (ASDI and nCS). Also, the buffer must only drive the slave devices to ensure that the timing between the master device and the serial configuration device is unaffected. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–15 This configuration method supports both compressed and uncompressed .sof files. Therefore, if the configuration bitstream size exceeds the capacity of a serial configuration device, you can enable the compression feature in the .sof or you can select a larger serial configuration device. Guidelines for Connecting Serial Configuration Device to Cyclone IV Devices on a AS Interface For single- and multi-device AS configurations, the board trace length and loading between the supported serial configuration device and Cyclone IV device must follow the recommendations in Table 8–5. Table 8–5. Maximum Trace Length and Loading for AS Configuration Cyclone IV Device AS Pins Maximum Board Trace Length from Cyclone IV Device to Serial Configuration Device (Inches) Maximum Board Load (pF) DCLK 6 15 DATA[0] 6 30 nCSO 6 30 ASDO 6 30 Estimating AS Configuration Time AS configuration time is dominated by the time it takes to transfer data from the serial configuration device to the Cyclone IV device. This serial interface is clocked by the Cyclone IV device DCLK output (generated from an internal oscillator). Equation 8–2 and Equation 8–3 show configuration time estimations for Cyclone IV devices. Equation 8–2. maximum DCLK period RBF Size × ⎛⎝ -------------------------------------------------------⎞⎠ = estimated maximum configuration time 1 bit Equation 8–3. 50 ns 3,500,000 bits × ⎛⎝ -------------⎞⎠ = 175 ms 1 bit Enabling compression reduces the amount of configuration data that is sent to the Cyclone IV device, which also reduces configuration time. On average, compression reduces configuration time by 50%. Programming Serial Configuration Devices Serial configuration devices are non-volatile, flash memory-based devices. You can program these devices in-system with the USB-Blaster™ or ByteBlaster™ II download cables. Alternatively, you can program them with the Altera Programming Unit (APU), supported third-party programmers, or a microprocessor with the SRunner software driver. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–16 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration You can perform in-system programming of serial configuration devices through the AS programming interface. During in-system programming, the download cable disables device access to the AS interface by driving the nCE pin high. Cyclone IV devices are also held in reset by a low level on nCONFIG. After programming is complete, the download cable releases nCE and nCONFIG, allowing the pull-down and pull-up resistors to drive GND and V CC , respectively. To perform in-system programming of a serial configuration device through the AS programming interface, the diodes and capacitors must be placed as close as possible to the Cyclone IV device. You must ensure that the diodes and capacitors maintain a maximum AC voltage of 4.1 V (refer to Figure 8–6). 1 If you want to use the same setup shown in Figure 8–6 to perform in-system programming of a serial configuration device and single- or multi-device AS configuration, you do not require a series resistor on the DATA line at the near end of the serial configuration device. The existing diodes and capacitors are sufficient. Altera has developed the Serial FlashLoader (SFL), a JTAG-based in-system programming solution for Altera serial configuration devices. The SFL is a bridge design for the Cyclone IV device that uses its JTAG interface to access the EPCS JIC (JTAG Indirect Configuration Device Programming) file and then uses the AS interface to program the EPCS device. Both the JTAG interface and AS interface are bridged together inside the SFL design. f For more information about implementing the SFL with Cyclone IV devices, refer to AN 370: Using the Serial FlashLoader with the Quartus II Software. f For more information about the USB-Blaster download cable, refer to the USB-Blaster Download Cable User Guide. For more information about the ByteBlaster II download cable, refer to the ByteBlaster II Download Cable User Guide. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–17 Figure 8–6 shows the download cable connections to the serial configuration device. Figure 8–6. In-System Programming of Serial Configuration Devices VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ VCCIO (1) 10 kΩ Cyclone IV Device Family nSTATUS CONF_DONE nCONFIG nCE 3.3 V 10 kΩ Serial Configuration Device nCEO N.C. (2) 3.3 V 3.3 V 3.3 V GND (5) DATA[0] (6) DCLK (6) nCSO ASDO DATA DCLK nCS ASDI Pin 1 (7) MSEL[3..0] (4) 3.3 V (3) GND 10 pf 10 pf 10 pf GND ByteBlaster II or USB Blaster 10-Pin Male Header GND GND GND 10 pf (5) GND Notes to Figure 8–6: (1) (2) (3) (4) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. Power up the VCC of the ByteBlaster II or USB-Blaster download cable with the 3.3-V supply. The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (5) The diodes and capacitors must be placed as close as possible to the Cyclone IV device. You must ensure that the diodes and capacitors maintain a maximum AC voltage of 4.1 V. The external diodes and capacitors are required to prevent damage to the Cyclone IV device AS configuration input pins due to possible overshoot when programming the serial configuration device with a download cable. Altera recommends using the Schottky diode, which has a relatively lower forward diode voltage (VF) than the switching and Zener diodes, for effective voltage clamping. (6) When cascading Cyclone IV devices in a multi-device AS configuration, connect the repeater buffers between the master and slave devices for DATA[0] and DCLK. All I/O inputs must maintain a maximum AC voltage of 4.1 V. The output resistance of the repeater buffers must fit the maximum overshoot equation outlined in “Configuration and JTAG Pin I/O Requirements” on page 8–4. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–18 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration You can use the Quartus II software with the APU and the appropriate configuration device programming adapter to program serial configuration devices. All serial configuration devices are offered in an 8- or 16-pin small outline integrated circuit (SOIC) package. In production environments, serial configuration devices are programmed using multiple methods. Altera programming hardware or other third-party programming hardware is used to program blank serial configuration devices before they are mounted onto PCBs. Alternatively, you can use an on-board microprocessor to program the serial configuration device in-system by porting the reference C-based SRunner software driver provided by Altera. A serial configuration device is programmed in-system by an external microprocessor with the SRunner software driver. The SRunner software driver is a software driver developed for embedded serial configuration device programming, which is easily customized to fit in different embedded systems. The SRunner software driver is able to read a Raw Programming Data (.rpd) file and write to serial configuration devices. The serial configuration device programming time, using the SRunner software driver, is comparable to the programming time with the Quartus II software. f For more information about the SRunner software driver, refer to AN 418: SRunner: An Embedded Solution for Serial Configuration Device Programming and the source code at the Altera website (www.altera.com). PS Configuration You can perform PS configuration on Cyclone IV devices with an external intelligent host, such as a MAX II device, microprocessor with flash memory, or a download cable. In the PS scheme, an external host controls the configuration. Configuration data is clocked into the target Cyclone IV device through DATA[0] at each rising edge of DCLK. If your system already contains a common flash interface (CFI) flash memory, you can use it for Cyclone IV device configuration storage as well. The MAX II PFL feature provides an efficient method to program CFI flash memory devices through the JTAG interface and the logic to control the configuration from the flash memory device to the Cyclone IV device. f 1 For more information about the PFL, refer to AN 386: Using the Parallel Flash Loader with the Quartus II Software. Cyclone IV devices do not support enhanced configuration devices for PS configuration. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–19 PS Configuration Using an External Host In the PS configuration scheme, you can use an intelligent host such as a MAX II device or microprocessor that controls the transfer of configuration data from a storage device, such as flash memory, to the target Cyclone IV device. You can store the configuration data in .rbf, .hex, or .ttf format. Figure 8–7 shows the configuration interface connections between a Cyclone IV device and an external host device for single-device configuration. Figure 8–7. Single-Device PS Configuration Using an External Host Memory VCCIO (1) VCCIO (1) ADDR Cyclone IV Device Family DATA[0] 10 kΩ External Host (MAX II Device or Microprocessor) 10 kΩ GND (5) MSEL[3..0] (3) CONF_DONE nSTATUS nCE nCEO N.C. (2) DATA[0] (4) nCONFIG DCLK (4) Notes to Figure 8–7: (1) Connect the pull-up resistor to a supply that provides an acceptable input signal for the device. VCC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (3) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (4) All I/O inputs must maintain a maximum AC voltage of 4.1-V. DATA[0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. (5) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. To begin the configuration, the external host device must generate a low-to-high transition on the nCONFIG pin. When nSTATUS is pulled high, the external host device must place the configuration data one bit at a time on DATA[0]. If you use configuration data in .rbf, .ttf, or .hex, you must first send the LSB of each data byte. For example, if the .rbf contains the byte sequence 02 1B EE 01 FA, the serial bitstream you must send to the device is: 0100-0000 1101-1000 0111-0111 1000-0000 0101-1111 Cyclone IV devices receive configuration data on DATA[0] and the clock is received on DCLK. Data is latched into the device on the rising edge of DCLK. Data is continuously clocked into the target device until CONF_DONE goes high and the device enters initialization state. 1 Two DCLK falling edges are required after CONF_DONE goes high to begin the initialization of the device. INIT_DONE is released and pulled high when initialization is complete. The external host device must be able to detect this low-to-high transition which signals the device has entered user mode. When initialization is complete, the device enters user mode. In user mode, the user I/O pins no longer have weak pull-up resistors and function as assigned in your design. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–20 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration To ensure DCLK and DATA[0] are not left floating at the end of configuration, the MAX II device must drive them either high or low, whichever is convenient on your board. The DATA[0] pin is available as a user I/O pin after configuration. When you choose the PS scheme in the Quartus II software, DATA[0] is tri-stated by default in user mode and must be driven by the external host device. To change this default option in the Quartus II software, select the Dual-Purpose Pins tab of the Device and Pin Options dialog box. The configuration clock (DCLK) speed must be below the specified system frequency to ensure correct configuration. No maximum DCLK period exists, which means you can pause configuration by halting DCLK for an indefinite amount of time. The external host device can also monitor CONF_DONE and INIT_DONE to ensure successful configuration. The CONF_DONE pin must be monitored by the external device to detect errors and to determine when programming is complete. If all configuration data is sent, but CONF_DONE or INIT_DONE has not gone high, the external device must reconfigure the target device. Figure 8–8 shows how to configure multiple devices using an external host device. This circuit is similar to the PS configuration circuit for a single device, except that Cyclone IV devices are cascaded for multi-device configuration. Figure 8–8. Multi-Device PS Configuration Using an External Host Memory VCCIO (1) VCCIO (1) Cyclone IV Device Family 1 ADDR DATA[0] 10 kΩ External Host (MAX II Device or Microprocessor) VCCIO (2) Cyclone IV Device Family 2 10 kΩ 10 kΩ (6) MSEL[3..0] (4) (6) MSEL[3..0] (4) CONF_DONE nSTATUS nCE nCEO CONF_DONE nSTATUS nCE nCEO N.C. (3) DATA[0] (5) nCONFIG DCLK (5) DATA[0] (5) nCONFIG DCLK (5) GND Buffers (5) Notes to Figure 8–8: (1) The pull-up resistor must be connected to a supply that provides an acceptable input signal for all devices in the chain. V CC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) Connect the pull-up resistor to the VCCIO supply voltage of the I/O bank in which the nCE pin resides. (3) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (4) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (5) All I/O inputs must maintain a maximum AC voltage of 4.1 V. DATA[0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. (6) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–21 After the first device completes configuration in a multi-device configuration chain, its nCEO pin drives low to activate the nCE pin of the second device, which prompts the second device to begin configuration. The second device in the chain begins configuration in one clock cycle. Therefore, the transfer of data destinations is transparent to the external host device. All other configuration pins (nCONFIG, nSTATUS, DCLK, DATA[0], and CONF_DONE) are connected to every device in the chain. Configuration signals can require buffering to ensure signal integrity and prevent clock skew problems. Ensure that the DCLK and DATA lines are buffered. Because all device CONF_DONE pins are tied together, all devices initialize and enter user mode at the same time. If any device detects an error, configuration stops for the entire chain and the entire chain must be reconfigured, because all nSTATUS and CONF_DONE pins are tied together. For example, if the first device flags an error on nSTATUS, it resets the chain by pulling its nSTATUS pin low. This behavior is similar to a single device detecting an error. You can have multiple devices that contain the same configuration data in your system. To support this configuration scheme, all device nCE inputs are tied to GND, while nCEO pins are left floating. All other configuration pins (nCONFIG, nSTATUS, DCLK, DATA[0], and CONF_DONE) are connected to every device in the chain. Configuration signals can require buffering to ensure signal integrity and prevent clock skew problems. Ensure that the DCLK and DATA lines are buffered. Devices must be of the same density and package. All devices start and complete configuration at the same time. Figure 8–9 shows a multi-device PS configuration when both Cyclone IV devices are receiving the same configuration data. Figure 8–9. Multi-Device PS Configuration When Both Devices Receive the Same Data Memory VCCIO (1) VCCIO (1) Cyclone IV Device Family ADDR Cyclone IV Device Family DATA[0] 10 kΩ External Host (MAX II Device or Microprocessor) 10 kΩ (5) MSEL[3..0] CONF_DONE nSTATUS nCE nCEO GND DATA[0] (4) nCONFIG DCLK (4) (3) (5) MSEL[3..0] CONF_DONE nSTATUS nCE nCEO N.C. (2) (3) N.C. (2) GND DATA[0] (4) nCONFIG DCLK (4) Buffers (4) Notes to Figure 8–9: (1) The pull-up resistor must be connected to a supply that provides an acceptable input signal for all devices in the chain. V CC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) The nCEO pins of both devices are left unconnected or used as user I/O pins when configuring the same configuration data into multiple devices. (3) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (4) All I/O inputs must maintain a maximum AC voltage of 4.1 V. DATA[0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. (5) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–22 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration PS Configuration Timing A PS configuration must meet the setup and hold timing parameters and the maximum clock frequency. When using a microprocessor or another intelligent host to control the PS interface, ensure that you meet these timing requirements. Figure 8–10 shows the timing waveform for PS configuration when using an external host device. Figure 8–10. PS Configuration Timing Waveform (Note 1) tCF2ST1 tCFG tCF2CK nCONFIG nSTATUS (2) tSTATUS tCF2ST0 t CLK CONF_DONE (3) tCF2CD tST2CK tCH tCL DCLK (4) tDH Bit 0 Bit 1 Bit 2 Bit 3 DATA[0] Bit n (5) tDSU User I/O Tri-stated with internal pull-up resistor User Mode INIT_DONE tCD2UM Notes to Figure 8–10: (1) The beginning of this waveform shows the device in user mode. In user mode, nCONFIG, nSTATUS, and CONF_DONE are at logic-high levels. When nCONFIG is pulled low, a reconfiguration cycle begins. (2) Upon power-up, the Cyclone IV device holds nSTATUS low during POR delay. (3) Upon power-up, before and during configuration, CONF_DONE is low. (4) In user mode, drive DCLK either high or low when using the PS configuration scheme, whichever is more convenient. When using the AS configuration scheme, DCLK is a Cyclone IV device output pin and should not be driven externally. (5) Do not leave the DATA[0] pin floating after configuration. Drive it high or low, whichever is more convenient. Table 8–6 defines the PS configuration timing parameters for Cyclone IV devices. Table 8–6. PS Configuration Timing Parameters for Cyclone IV Devices (Part 1 of 2) (Note 1) Symbol Parameter Minimum Maximum Unit tCF 2CD nCONFIG low to CONF_DONE low — 500 ns tCF 2ST0 nCONFIG low to nSTATUS low — 500 ns tCF G nCONFIG low pulse width 500 — ns tSTATUS nSTATUS low pulse width 45 230 (2) μs tCF 2ST1 nCONFIG high to nSTATUS high — 230 (2) μs tCF 2CK nCONFIG high to first rising edge on DCLK 230 (2) — μs tST2C K nSTATUS high to first rising edge of DCLK 2 — μs tDSU Data setup time before rising edge on DCLK 5 — ns tDH Data hold time after rising edge on DCLK 0 — ns tCH DCLK high time 3.2 — ns tCL DCLK low time 3.2 — ns Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–23 Table 8–6. PS Configuration Timing Parameters for Cyclone IV Devices (Part 2 of 2) (Note 1) Symbol Parameter Minimum Maximum Unit tCLK DCLK period 7.5 — ns fM AX DCLK frequency — 133 MHz tCD2UM CONF_DONE high to user mode (3) 300 650 μs tCD2C U CONF_DONE high to CLKUSR enabled 4 × maximum DCLK period — — tCD2UM C CONF_DONE high to user mode with CLKUSR option on tCD2C U + (3,187 × CLKUSR period) — — Notes to Table 8–6: (1) This information is preliminary. (2) This value is applicable if you do not delay configuration by extending the nCONFIG or nSTATUS low pulse width. (3) The minimum and maximum numbers apply only if the internal oscillator is chosen as the clock source for starting the device. PS Configuration Using a Download Cable In this section, the generic term “download cable” includes the Altera USB-Blaster USB port download cable, MasterBlaster™ serial/USB communications cable, ByteBlaster II parallel port download cable, the ByteBlasterMV™ parallel port download cable, and the Ethernet-Blaster communications cable. In PS configuration with a download cable, an intelligent host (such as a PC) transfers data from a storage device to the Cyclone IV device through the download cable. The programming hardware or download cable then places the configuration data one bit at a time on the DATA[0] pin of the device. The configuration data is clocked into the target device until CONF_DONE goes high. The CONF_DONE pin must have an external 10-kΩ pull-up resistor for the device to initialize. When you use a download cable, setting the Auto-restart configuration after error option does not affect the configuration cycle because you must manually restart configuration in the Quartus II software if an error occurs. Additionally, the Enable user-supplied start-up clock (CLKUSR) option has no effect on device initialization, because this option is disabled in the .sof when programming the device with the Quartus II Programmer and download cable. Therefore, if you turn on the CLKUSR option, you do not have to provide a clock on CLKUSR when you configure the device with the Quartus II Programmer and a download cable. Figure 8–11 shows PS configuration for Cyclone IV devices with a download cable. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–24 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Figure 8–11. PS Configuration Using a USB-Blaster, MasterBlaster, ByteBlaster II, or ByteBlasterMV Cable VCCA (1) (2) VCCA (1) 10 kΩ 10 kΩ VCCA (1) VCCA (1) VCCA (1) 10 kΩ 10 kΩ 10 kΩ (2) Cyclone IV Device Family CONF_DONE nSTATUS MSEL[3..0] (5), (7) nCE nCEO N.C. (4) Download Cable 10-Pin Male Header (Top View) GND DCLK DATA[0] nCONFIG Pin 1 VCCA (6) GND VIO (3) Shield GND Notes to Figure 8–11: (1) The pull-up resistor must be connected to the same supply voltage as the VCCA supply. (2) The pull-up resistors on DATA[0] and DCLK are only required if the download cable is the only configuration scheme used on your board. This is to ensure that DATA[0] and DCLK are not left floating after configuration. For example, if you also use a configuration device, the pull-up resistors on DATA[0] and DCLK are not required. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the VCCA of the device. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. With the USB Blaster, ByteBlaster II, ByteBlaster MV, and Ethernet Blaster, this pin is a no connect. (4) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (5) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7 for PS configuration schemes. Connect the MSEL pins directly to VCCA or GND. (6) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5-V supply from VCCA . Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. You can use a download cable to configure multiple Cyclone IV device configuration pins. nCONFIG, nSTATUS, DCLK, DATA[0], and CONF_DONE are connected to every device in the chain. Because all CONF_DONE pins are tied together, all devices in the chain initialize and enter user mode at the same time. In addition, the entire chain halts configuration if any device detects an error because the nSTATUS pins are tied together. The Auto-restart configuration after error option does not affect the configuration cycle, because you must manually restart configuration in the Quartus II software if an error occurs. Figure 8–12 shows PS configuration for multiple Cyclone IV devices using a MasterBlaster, USB-Blaster, ByteBlaster II, or ByteBlasterMV cable. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–25 Figure 8–12. Multi-Device PS Configuration Using a USB-Blaster, MasterBlaster, ByteBlaster II, or ByteBlasterMV Cable VCCA (1) VCCA (1) VCCA (1) 10 kΩ 10 kΩ (2) VCCIO (4) 10 kΩ VCCA (1) 10 kΩ (2) VCCA (1) Download Cable 10-Pin Male Header (Passive Serial Mode) 10 kΩ Cyclone IV Device Family 1 CONF_DONE nSTATUS DCLK MSEL[3..0] (6), (8) Pin 1 VCCA (7) GND VIO (3) nCE 10 kΩ GND DATA[0] nCONFIG nCEO GND Cyclone IV Device Family 2 CONF_DONE nSTATUS MSEL[3..0] DCLK (6), (8) nCE nCEO N.C. (5) DATA[0] nCONFIG Notes to Figure 8–12: (1) The pull-up resistor must be connected to the same supply voltage as the VCCA supply. (2) The pull-up resistors on DATA[0] and DCLK are only required if the download cable is the only configuration scheme used on your board. This ensures that DATA[0] and DCLK are not left floating after configuration. For example, if you also use a configuration device, the pull-up resistors on DATA[0] and DCLK are not required. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the VCCA of the device. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. When using the ByteBlasterMV download cable, this pin is a no connect. When using USB-Blaster, ByteBlaster II, and Ethernet Blaster cables, this pin is connected to nCE when it is used for AS programming. Otherwise, it is a no connect. (4) Connect the pull-up resistor to the VCCIO supply voltage of the I/O bank in which the nCE pin resides. (5) The nCEO pin of the last device in the chain is left unconnected or used as a user I/O pin. (6) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect MSEL for PS configuration schemes, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (7) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5 V supply from VCCA. Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (8) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–26 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration FPP Configuration 1 FPP configuration is only supported in EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices. The FPP configuration in Cyclone IV devices is designed to meet the increasing demand for faster configuration time. Cyclone IV devices are designed with the capability of receiving byte-wide configuration data per clock cycle. You can perform FPP configuration of Cyclone IV devices with an intelligent host, such as a MAX II device or microprocessor with flash memory. If your system already contains a CFI flash memory, you can use it for the Cyclone IV device configuration storage as well. The MAX II PFL feature in MAX II devices provides an efficient method to program CFI flash memory devices through the JTAG interface and the logic to control configuration from the flash memory device to the Cyclone IV device. f 1 For more information about the PFL, refer to AN 386: Using the Parallel Flash Loader with the Quartus II Software. Cyclone IV devices do not support enhanced configuration devices for FPP configuration. FPP Configuration Using an External Host FPP configuration using an external host provides a fast method to configure Cyclone IV devices. In the FPP configuration scheme, you can use an external host device to control the transfer of configuration data from a storage device, such as flash memory, to the target Cyclone IV device. You can store configuration data in an .rbf, .hex, or .ttf format. When using the external host, a design that controls the configuration process, such as fetching the data from flash memory and sending it to the device, must be stored in the external host device. Figure 8–13 shows the configuration interface connections between the Cyclone IV devices and an external device for single-device configuration. Figure 8–13. Single-Device FPP Configuration Using an External Host Memory VCCIO(1) VCCIO(1) ADDR DATA[7..0] 10 kΩ External Host (MAX II Device or Microprocessor) Cyclone IV Device Family 10 kΩ GND MSEL[3..0] (3) CONF_DONE nSTATUS nCEO nCE N.C. (2) DATA[7..0] (4) nCONFIG DCLK (4) Notes to Figure 8–13: (1) Connect the pull-up resistor to a supply that provides an acceptable input signal for the device. VCC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (3) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (4) All I/O inputs must maintain a maximum AC voltage of 4.1 V. DATA[7..0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–27 After nSTATUS is released, the device is ready to receive configuration data and the configuration stage begins. When nSTATUS is pulled high, the external host device places the configuration data one byte at a time on the DATA[7..0]pins. Cyclone IV devices receive configuration data on the DATA[7..0] pins and the clock is received on the DCLK pin. Data is latched into the device on the rising edge of DCLK. Data is continuously clocked into the target device until CONF_DONE goes high. The CONF_DONE pin goes high one byte early in FPP configuration mode. The last byte is required for serial configuration (AS and PS) modes. 1 Two DCLK falling edges are required after CONF_DONE goes high to begin the initialization of the device. Supplying a clock on CLKUSR does not affect the configuration process. After the CONF_DONE pin goes high, CLKUSR is enabled after the time specified as tCD2CU. After this time period elapses, Cyclone IV devices require 3,187 clock cycles to initialize properly and enter user mode. For more information about the supported CLKUSR fMAX value for Cyclone IV devices, refer to Table 8–7 on page 8–30. The INIT_DONE pin is released and pulled high when initialization is complete. The external host device must be able to detect this low-to-high transition, which signals the device has entered user mode. When initialization is complete, the device enters user mode. In user mode, the user I/O pins no longer have weak pull-up resistors and function as assigned in your design. To ensure that DCLK and DATA[0] are not left floating at the end of the configuration, the MAX II device must drive them either high or low, whichever is convenient on your board. The DATA[0] pin is available as a user I/O pin after configuration. When you choose the FPP scheme in the Quartus II software, the DATA[0] pin is tri-stated by default in user mode and must be driven by the external host device. To change this default option in the Quartus II software, select the Dual-Purpose Pins tab of the Device and Pin Options dialog box. The DCLK speed must be below the specified system frequency to ensure correct configuration. No maximum DCLK period exists, which means you can pause configuration by halting DCLK for an indefinite amount of time. The external host device can also monitor the CONF_DONE and INIT_DONE pins to ensure successful configuration. The CONF_DONE pin must be monitored by the external device to detect errors and to determine when programming is complete. If all configuration data is sent, but CONF_DONE or INIT_DONE has not gone high, the external device must reconfigure the target device. Figure 8–14 shows how to configure multiple devices with a MAX II device. This circuit is similar to the FPP configuration circuit for a single device, except Cyclone IV devices are cascaded for multi-device configuration. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–28 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Figure 8–14. Multi-Device FPP Configuration Using an External Host Memory VCCIO (1) VCCIO (1) ADDR DATA[7..0] VCCIO (2) Cyclone IV Device Family 2 10 kΩ 10 kΩ External Host (MAX II Device or Microprocessor) Cyclone IV Device Family 1 10 kΩ (4) MSEL[3..0] (4) CONF_DONE nSTATUS nCE nCEO CONF_DONE nSTATUS nCE nCEO N.C. (3) DATA[7..0] (5) nCONFIG DCLK (5) DATA[7..0] (5) nCONFIG DCLK (5) MSEL[3..0] GND Buffers (5) Notes to Figure 8–14: (1) The pull-up resistor must be connected to a supply that provides an acceptable input signal for all devices in the chain. V CC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) Connect the pull-up resistor to the VCCIO supply voltage of the I/O bank in which the nCE pin resides. (3) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (4) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (5) All I/O inputs must maintain a maximum AC voltage of 4.1 V. DATA[7..0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. After the first device completes configuration in a multi-device configuration chain, its nCEO pin drives low to activate the nCE pin of the second device, which prompts the second device to begin configuration. The second device in the chain begins configuration in one clock cycle; therefore, the transfer of data destinations is transparent to the MAX II device. All other configuration pins (nCONFIG, nSTATUS, DCLK, DATA[7..0], and CONF_DONE) are connected to every device in the chain. Configuration signals may require buffering to ensure signal integrity and prevent clock skew problems. Ensure that the DCLK and DATA lines are buffered. All devices initialize and enter user mode at the same time, because all device CONF_DONE pins are tied together. All nSTATUS and CONF_DONE pins are tied together and if any device detects an error, configuration stops for the entire chain and the entire chain must be reconfigured. For example, if the first device flags an error on nSTATUS, it resets the chain by pulling its nSTATUS pin low. This behavior is similar to a single device detecting an error. Figure 8–15 shows multi-device FPP configuration when both Cyclone IV devices are receiving the same configuration data. Configuration pins (nCONFIG, nSTATUS, DCLK, DATA[7..0], and CONF_DONE) are connected to every device in the chain. Configuration signals can require buffering to ensure signal integrity and prevent clock skew problems. Ensure that the DCLK and DATA lines are buffered. Devices must be of the same density and package. All devices start and complete configuration at the same time. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–29 Figure 8–15. Multi-Device FPP Configuration Using an External Host When Both Devices Receive the Same Data Memory VCCIO (1) VCCIO (1) Cyclone IV Device Family 1 Cyclone IV Device Family 2 ADDR DATA[7..0] 10 kΩ 10 kΩ MSEL[3..0] External Host (MAX II Device or Microprocessor) CONF_DONE nSTATUS nCE nCEO GND (3) N.C. (2) GND DATA[7..0] (4) nCONFIG DCLK (4) MSEL[3..0] (3) CONF_DONE nSTATUS nCE nCEO N.C. (2) DATA[7..0] (4) nCONFIG DCLK (4) Buffers (4) Notes to Figure 8–15: (1) The pull-up resistor must be connected to a supply that provides an acceptable input signal for all devices in the chain. V CC must be high enough to meet the VIH specification of the I/O on the device and the external host. (2) The nCEO pins of both devices are left unconnected or used as user I/O pins when configuring the same configuration data into multiple devices. (3) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect the MSEL pins, refer to Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (4) All I/O inputs must maintain a maximum AC voltage of 4.1 V. DATA[7..0] and DCLK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. You can use a single configuration chain to configure Cyclone IV devices with other Altera devices that support FPP configuration. To ensure that all devices in the chain complete configuration at the same time or that an error flagged by one device starts reconfiguration in all devices, tie all the CONF_DONE and nSTATUS pins together. f For more information about configuring multiple Altera devices in the same configuration chain, refer to Configuring Mixed Altera FPGA Chains in volume 2 of the Configuration Handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–30 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration FPP Configuration Timing Figure 8–16 shows the timing waveform for FPP configuration when using an external host. Figure 8–16. FPP Configuration Timing Waveform (Note 1) tCF2ST1 tCFG tCF2CK nCONFIG nSTATUS (2) tSTATUS tCF2ST0 t CLK CONF_DONE (3) tCF2CD tST2CK tCH tCL (4) DCLK tDH DATA[7..0] Byte 0 Byte 1 Byte 2 Byte 3 Byte n-1 (5) Byte n User Mode tDSU User I/O User Mode High-Z INIT_DONE tCD2UM Notes to Figure 8–16: (1) The beginning of this waveform shows the device in user mode. In user mode, nCONFIG, nSTATUS, and CONF_DONE are at logic-high levels. When nCONFIG is pulled low, a reconfiguration cycle begins. (2) Upon power-up, the Cyclone IV device holds nSTATUS low during POR delay. (3) Upon power-up, before and during configuration, CONF_DONE is low. (4) Do not leave DCLK floating after configuration. It must be driven high or low, whichever is more convenient. (5) DATA[7..0] is available as user I/O pin after configuration; the state of the pin depends on the dual-purpose pin settings. Table 8–7 defines the FPP configuration timing parameters for Cyclone IV devices. Table 8–7. FPP Timing Parameters for Cyclone IV Devices Symbol (Note 1) Parameter (Part 1 of 2) Minimum Maximum Unit tCF 2CD nCONFIG low to CONF_DONE low — 500 ns tCF 2ST0 nCONFIG low to nSTATUS low — 500 ns tCF G nCONFIG low pulse width 500 — ns tSTATUS nSTATUS low pulse width 45 230 (2) μs tCF 2ST1 nCONFIG high to nSTATUS high — 230 (2) μs tCF 2CK nCONFIG high to first rising edge on DCLK 230 (2) — μs tST2C K nSTATUS high to first rising edge of DCLK 2 — μs tDSU DATA setup time before rising edge on DCLK 5 — ns tDH DATA hold time after rising edge on DCLK 0 — ns tCH DCLK high time 3.2 — ns tCL DCLK low time 3.2 — ns tCLK DCLK period 7.5 — ns fM AX DCLK frequency — 100 MHz tCD2UM CONF_DONE high to user mode (3) 300 650 μs Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–7. FPP Timing Parameters for Cyclone IV Devices Symbol 8–31 (Note 1) Parameter (Part 2 of 2) Minimum Maximum Unit tCD2C U CONF_DONE high to CLKUSR enabled 4 × maximum DCLK period — — tCD2UM C CONF_DONE high to user mode with CLKUSR option on t C D2CU + (3,187 × CLKUSR period) — — Notes to Table 8–7: (1) This information is preliminary. (2) This value is applicable if users do not delay configuration by extending the nCONFIG or nSTATUS low pulse width. (3) The minimum and maximum numbers apply only if the internal oscillator is chosen as the clock source for starting up the device. JTAG Configuration JTAG has developed a specification for boundary-scan testing. This boundary-scan test (BST) architecture offers the capability to efficiently test components on PCBs with tight lead spacing. The BST architecture can test pin connections without using physical test probes and capture functional data while a device is operating normally. You can also use JTAG circuitry to shift configuration data into the device. The Quartus II software automatically generates .sof files for JTAG configuration with a download cable in the Quartus II software Programmer. f For more information about the JTAG boundary-scan testing, refer to the JTAG Boundary-Scan Testing for Cyclone IV Devices chapter in volume 1 of the Cyclone IV Device Handbook. Cyclone IV devices are designed for JTAG instructions to have precedence over any device configuration modes. Therefore, JTAG configuration can take place without waiting for other configuration modes to complete. For example, if you attempt JTAG configuration in Cyclone IV devices during PS configuration, PS configuration terminates and JTAG configuration begins. If the MSEL pins are set to AS mode, the Cyclone IV device does not output a DCLK signal when JTAG configuration takes place. The four required pins for a device operating in JTAG mode are TDI, TDO, TMS, and TCK. All the JTAG input pins are powered by the VCCIO pin and support only LVTTL I/O standard. All user I/O pins are tri-stated during JTAG configuration. Table 8–8 explains the function of each JTAG pin. Table 8–8. Dedicated JTAG Pins (Part 1 of 2) Pin Name Pin Type Description TDI Test data input Serial input pin for instructions as well as test and programming data. Data shifts in on the rising edge of TCK. If the JTAG interface is not required on the board, the JTAG circuitry is disabled by connecting this pin to VCC. TDI pins have weak internal pull-up resistors (typically 25 kΩ). TDO Test data output Serial data output pin for instructions as well as test and programming data. Data shifts out on the falling edge of TCK. The pin is tri-stated if data is not being shifted out of the device. If the JTAG interface is not required on the board, the JTAG circuitry is disabled by leaving this pin unconnected. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–32 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–8. Dedicated JTAG Pins (Part 2 of 2) Pin Name Pin Type Description TMS Test mode select Input pin that provides the control signal to determine the transitions of the TAP controller state machine. Transitions in the state machine occur on the rising edge of TCK. Therefore, TMS must be set up before the rising edge of TCK. TMS is evaluated on the rising edge of TCK. If the JTAG interface is not required on the board, the JTAG circuitry is disabled by connecting this pin to VCC. TMS pins have weak internal pull-up resistors (typically 25 kΩ). TCK Test clock input The clock input to the BST circuitry. Some operations occur at the rising edge, while others occur at the falling edge. If the JTAG interface is not required on the board, the JTAG circuitry is disabled by connecting this pin to GND. The TCK pin has an internal weak pull-down resistor. You can download data to the device through the USB-Blaster, MasterBlaster, ByteBlaster II, or ByteBlasterMV download cable, or the Ethernet-Blaster communications cable during JTAG configuration. Configuring devices with a cable is similar to programming devices in-system. Figure 8–17 and Figure 8–18 show the JTAG configuration of a single Cyclone IV device. For device V CCIO of 2.5/3.0/3.3 V, refer to Figure 8–17. All I/O inputs must maintain a maximum AC voltage of 4.1 V. Because JTAG pins do not have the internal PCI clamping diodes to prevent voltage overshoot when using VCCIO of 2.5/3.0/3.3 V, you must power up the VCC of the download cable with a 2.5-V supply from VCCA. For device VCCIO of 1.2/1.5/1.8 V, refer to Figure 8–18. You can power up the VCC of the download cable with the supply from VCCIO. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–33 Figure 8–17. JTAG Configuration of a Single Device Using a Download Cable (2.5/3.0/3.3-V VCCIO Powering the JTAG Pins) VCCA 10 kΩ VCCIO (1) VCCIO (1) VCCA 10 kΩ 10 kΩ GND N.C. (5) (2) (2) (2) (2) Cyclone IV Device Family nCE (4) TCK TDO nCEO nSTATUS CONF_DONE nCONFIG MSEL[3..0] (7) DATA[0] DCLK 10 kΩ Download Cable 10-Pin Male Header (Top View) TMS TDI Pin 1 VCCA (6) GND VIO (3) 1 kΩ GND GND Notes to Figure 8–17: (1) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. (2) Connect the nCONFIG and MSEL pins to support a non-JTAG configuration scheme. If you only use JTAG configuration, connect the nCONFIG pin to logic-high and the MSEL pins to GND. In addition, pull DCLK and DATA[0] to either high or low, whichever is convenient on your board. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the device’s VCCA . For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. When using the USB-Blaster, ByteBlaster II, ByteBlasterMV, and Ethernet Blaster cables, this pin is a no connect. (4) The nCE pin must be connected to GND or driven low for successful JTAG configuration. (5) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (6) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5-V supply from VCCA . Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–34 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Figure 8–18. JTAG Configuration of a Single Device Using a Download Cable (1.5 V or 1.8 V V CCIO Powering the JTAG Pins) VCCA 10 kΩ VCCIO (1) VCCIO (1) VCCA 10 kΩ 10 kΩ GND N.C. (5) (2) (2) (2) (2) Cyclone IV Device Family nCE (4) TCK TDO nCEO nSTATUS CONF_DONE nCONFIG MSEL[3..0] (7) DATA[0] DCLK 10 kΩ Download Cable 10-Pin Male Header (Top View) TMS TDI Pin 1 VCCA (6) GND VIO (3) 1 kΩ GND GND Notes to Figure 8–18: (1) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. (2) Connect the nCONFIG and MSEL pins to support a non-JTAG configuration scheme. If you only use JTAG configuration, connect the nCONFIG pin to logic-high and the MSEL pins to GND. In addition, pull DCLK and DATA[0] to either high or low, whichever is convenient on your board. (3) In the USB-Blaster and ByteBlaster II cables, this pin is connected to nCE when it is used for AS programming; otherwise it is a no connect. (4) The nCE must be connected to GND or driven low for successful JTAG configuration. (5) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (6) Power up the VCC of the ByteBlaster II or USB-Blaster cable with supply from VCCIO. The ByteBlaster II and USB-Blaster cables do not support a target supply voltage of 1.2 V. For the target supply voltage value, refer to the ByteBlaster II Download Cable User Guide and the USB-Blaster Download Cable User Guide. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. To configure a single device in a JTAG chain, the programming software places all other devices in bypass mode. In bypass mode, devices pass programming data from the TDI pin to the TDO pin through a single bypass register without being affected internally. This scheme enables the programming software to program or verify the target device. Configuration data driven into the device appears on the TDO pin one clock cycle later. The Quartus II software verifies successful JTAG configuration upon completion. At the end of configuration, the software checks the state of CONF_DONE through the JTAG port. When Quartus II generates a .jam for a multi-device chain, it contains instructions so that all the devices in the chain are initialized at the same time. If CONF_DONE is not high, the Quartus II software indicates that configuration has failed. If CONF_DONE is high, the software indicates that configuration was successful. After the configuration bitstream is serially sent via the JTAG TDI port, the TCK port clocks an additional 3,180 cycles to perform device initialization. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–35 You can perform JTAG testing on Cyclone IV devices before, during, and after configuration. Cyclone IV devices support the BYPASS, IDCODE, and SAMPLE instructions during configuration without interrupting configuration. All other JTAG instructions can only be issued by first interrupting configuration and reprogramming I/O pins with the ACTIVE_DISENGAGE and CONFIG_IO instructions. The CONFIG_IO instruction allows I/O buffers to be configured through the JTAG port and interrupts configuration when issued after the ACTIVE_DISENGAGE instruction. This instruction allows you to perform board-level testing prior to configuring the Cyclone IV device or waiting for a configuration device to complete configuration. Prior to issuing the CONFIG_IO instruction, you must issue the ACTIVE_DISENGAGE instruction. This is because in Cyclone IV devices, the CONFIG_IO instruction does not hold nSTATUS low until reconfiguration, so you must disengage the active configuration mode controller when active configuration is interrupted. The ACTIVE_DISENGAGE instruction places the active configuration mode controllers in an idle state prior to JTAG programming. Additionally, the ACTIVE_ENGAGE instruction allows you to re-engage a disengaged active configuration mode controller. 1 You must follow a specific flow when executing the ACTIVE_DISENGAGE, CONFIG_IO, and ACTIVE_ENGAGE JTAG instructions in Cyclone IV devices. The chip-wide reset (DEV_CLRn) and chip-wide output enable (DEV_OE) pins in Cyclone IV devices do not affect JTAG boundary-scan or programming operations. Toggling these pins does not affect JTAG operations (other than the usual boundary-scan operation). When designing a board for JTAG configuration of Cyclone IV devices, consider the dedicated configuration pins. Table 8–9 shows how these pins must be connected during JTAG configuration. Table 8–9. Dedicated Configuration Pin Connections During JTAG Configuration Signal Description nCE On all Cyclone IV devices in the chain, nCE must be driven low by connecting it to GND, pulling it low through a resistor, or driving it by some control circuitry. For devices that are also in multi-device AS, PS, or FPP configuration chains, the nCE pins must be connected to GND during JTAG configuration or JTAG configured in the same order as the configuration chain. nCEO On all Cyclone IV devices in the chain, nCEO is left floating or connected to the nCE of the next device. MSEL These pins must not be left floating. These pins support whichever non-JTAG configuration that is used in production. If only JTAG configuration is used, tie these pins to GND. nCONFIG Driven high by connecting to VCCIO supply of the bank in which the pin resides and pulling up through a resistor, or driven high by some control circuitry. nSTATUS Pull to the VCCIO supply of the bank in which the pin resides through a 10-kΩ resistor. When configuring multiple devices in the same JTAG chain, each nSTATUS pin must be pulled up to VCCIO individually. CONF_DONE Pull to the VCCIO supply of the bank in which the pin resides through a 10-kΩ resistor. When configuring multiple devices in the same JTAG chain, each CONF_DONE pin must be pulled up to VCCIO supply of the bank in which the pin resides individually. CONF_DONE going high at the end of JTAG configuration indicates successful configuration. DCLK Must not be left floating. Drive low or high, whichever is more convenient on your board. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–36 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration When programming a JTAG device chain, one JTAG-compatible header is connected to several devices. The number of devices in the JTAG chain is limited only by the drive capability of the download cable. When four or more devices are connected in a JTAG chain, Altera recommends buffering the TCK, TDI, and TMS pins with an on-board buffer. JTAG-chain device programming is ideal when the system contains multiple devices, or when testing your system with JTAG BST circuitry. Figure 8–19 and Figure 8–20 show multi-device JTAG configuration. For device V CCIO of 2.5/3.0/3.3 V, you must refer to Figure 8–19. All I/O inputs must maintain a maximum AC voltage of 4.1 V. Because JTAG pins do not have the internal PCI clamping diodes to prevent voltage overshoot when using V CCIO of 2.5/3.0/3.3 V, you must power up the VCC of the download cable with a 2.5-V supply from VCCA. For device VCCIO of 1.2 /1.5 V/1.8 V, refer to Figure 8–20. You can power up the VCC of the download cable with the supply from VCCIO. Figure 8–19. JTAG Configuration of Multiple Devices Using a Download Cable (2.5/3.0/ 3.3-V VCCIO Powering the JTAG Pins) Download Cable 10-Pin Male Header Pin 1 VCCIO(1) VCCA 10 kΩ VCCA (5) 10 kΩ VIO (3) (2) (2) (2) (2) (2) VCCIO (1) Cyclone IV Device 10 kΩ Family nSTATUS DATA[0] DCLK nCONFIG CONF_DONE MSEL[3..0] (6) nCEO nCE (4) TDI TMS TDO TCK VCCIO (1) VCCIO (1) Cyclone IV Device Family 10 kΩ 10 kΩ (2) (2) (2) (2) (2) nSTATUS DATA[0] DCLK nCONFIG CONF_DONE MSEL[3..0] (6) nCEO nCE (4) TDI TMS TDO TCK VCCIO (1) VCCIO (1) 10 kΩ 10 kΩ (2) (2) (2) (2) (2) Cyclone IV Device Family 10 kΩ nSTATUS DATA[0] DCLK nCONFIG CONF_DONE MSEL[3..0] (6) nCEO nCE (4) TDI TMS TDO TCK 1 kΩ Notes to Figure 8–19: (1) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. (2) Connect the nCONFIG and MSEL pins to support a non-JTAG configuration scheme. If you only use a JTAG configuration, connect the nCONFIG pin to logic-high and the MSEL pins to GND. In addition, pull DCLK and DATA[0] to either high or low, whichever is convenient on your board. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the VCCA of the device. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. In the ByteBlasterMV cable, this pin is a no connect. In the USB-Blaster and ByteBlaster II cables, this pin is connected to nCE when it is used for AS programming, otherwise it is a no connect. (4) The nCE pin must be connected to GND or driven low for successful JTAG configuration. (5) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5-V supply from V CCA. Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (6) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–37 Figure 8–20. JTAG Configuration of Multiple Devices Using a Download Cable (1.2/1.5/1.8-V V CCIO Powering the JTAG Pins) VCCIO Download Cable 10-Pin Male Header Pin 1 VCCIO (5) VCCIO 10 kΩ VCCIO (1) 10 kΩ VIO (3) (2) (2) (2) (2) (2) VCCIO (1) Cyclone IV 10 kΩ Device Family TDO TCK 10 kΩ 10 kΩ nSTATUS DATA[0] DCLK CONF_DONE nCONFIG MSEL[3..0] (6) nCEO nCE (4) TDI TMS VCCIO (1) (2) (2) (2) (2) (2) Cyclone IV Device Family VCCIO (1) TDO TCK 10 kΩ 10 kΩ nSTATUS DATA[0] DCLK nCONFIG CONF_DONE MSEL[3..0] (6) nCEO nCE (4) TDI TMS VCCIO (1) (2) (2) (2) (2) (2) VCCIO (1) Cyclone IV Device Family 10 kΩ nSTATUS DATA[0] DCLK nCONFIG CONF_DONE MSEL[3..0] (6) nCEO nCE (4) TDI TMS TDO TCK 1 kΩ Notes to Figure 8–20: (1) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. (2) Connect the nCONFIG and MSEL pins to support a non-JTAG configuration scheme. If you only use a JTAG configuration, connect the nCONFIG pin to logic-high and the MSEL pins to GND. In addition, pull DCLK and DATA[0] to either high or low, whichever is convenient on your board. (3) In the USB-Blaster and ByteBlaster II cable, this pin is connected to nCE when it is used for AS programming, otherwise it is a no connect. (4) The nCE pin must be connected to GND or driven low for successful JTAG configuration. (5) Power up the VCC of the ByteBlaster II or USB-Blaster cable with supply from VCCIO. The ByteBlaster II and USB-Blaster cables do not support a target supply voltage of 1.2 V. For the target supply voltage value, refer to the ByteBlaster II Download Cable User Guide and the USB-Blaster Download Cable User Guide. (6) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. 1 If a non-Cyclone IV device is cascaded in the JTAG-chain, TDO of the non-Cyclone IV device driving into TDI of the Cyclone IV device must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. The CONF_DONE and nSTATUS signals are shared in multi-device AS, PS, and FPP configuration chains to ensure that the devices enter user mode at the same time after configuration is complete. When the CONF_DONE and nSTATUS signals are shared among all the devices, every device must be configured when JTAG configuration is performed. If you only use JTAG configuration, Altera recommends that you connect the circuitry as shown in Figure 8–19 or Figure 8–20, in which each of the CONF_DONE and nSTATUS signals are isolated so that each device can enter user mode individually. After the first device completes configuration in a multi-device configuration chain, its nCEO pin drives low to activate the nCE pin of the second device, which prompts the second device to begin configuration. Therefore, if these devices are also in a JTAG chain, ensure that the nCE pins are connected to GND during JTAG configuration or that the devices are JTAG configured in the same order as the configuration chain. As long as the devices are JTAG configured in the same order as the multi-device configuration chain, the nCEO of the previous device drives the nCE pin of the next device low when it has successfully been JTAG configured. You can place other Altera devices that have JTAG support in the same JTAG chain for device programming and configuration. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–38 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 1 f JTAG configuration allows an unlimited number of Cyclone IV devices to be cascaded in a JTAG chain. For more information about configuring multiple Altera devices in the same configuration chain, refer to the Configuring Mixed Altera FPGA Chains chapter in volume 2 of the Configuration Handbook. Figure 8–21 shows JTAG configuration with a Cyclone IV device and a microprocessor. Figure 8–21. JTAG Configuration of a Single Device Using a Microprocessor Cyclone IV Device Family Memory nCE(3) ADDR DATA N.C. (2) (2) (2) Microprocessor nCEO (5) nCONFIG DATA[0] DCLK TDI (4) TCK (4) TMS (4) MSEL[3..0] (2) VCCIO (1) VCCIO (1) 10 kΩ 10 kΩ TDO nSTATUS CONF_DONE Notes to Figure 8–21: (1) The pull-up resistor must be connected to a supply that provides an acceptable input signal for all devices in the chain. (2) Connect the nCONFIG and MSEL pins to support a non-JTAG configuration scheme. If you only use a JTAG configuration, connect the nCONFIG pin to logic-high and the MSEL pins to GND. In addition, pull DCLK and DATA[0] to either high or low, whichever is convenient on your board. (3) The nCE pin must be connected to GND or driven low for successful JTAG configuration. (4) All I/O inputs must maintain a maximum AC voltage of 4.1 V. Signals driving into TDI, TMS, and TCK must fit the maximum overshoot outlined in Equation 8–1 on page 8–5. (5) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. Configuring Cyclone IV Devices with Jam STAPL Jam STAPL, JEDEC standard JESD-71, is a standard file format for in-system programmability (ISP) purposes. Jam STAPL supports programming or configuration of programmable devices and testing of electronic systems, using the IEEE 1149.1 JTAG interface. Jam STAPL is a freely licensed open standard. The Jam Player provides an interface for manipulating the IEEE Std. 1149.1 JTAG TAP state machine. f For more information about JTAG and Jam STAPL in embedded environments, refer to AN 425: Using Command-Line Jam STAPL Solution for Device Programming. To download the Jam Player, visit the Altera website (www.altera.com). Configuring Cyclone IV Devices with the JRunner Software Driver The JRunner software driver allows you to configure Cyclone IV devices through the ByteBlaster II or ByteBlasterMV cables in JTAG mode. The supported programming input file is in .rbf format. The JRunner software driver also requires a Chain Description File (.cdf) generated by the Quartus II software. The JRunner software driver is targeted for embedded JTAG configuration. The source code is developed for the Windows NT operating system (OS). You can customize the code to make it run on your embedded platform. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 1 f 8–39 The .rbf used by the JRunner software driver cannot be a compressed .rbf because the JRunner software driver uses JTAG-based configuration. During JTAG-based configuration, the real-time decompression feature is not available. For more information about the JRunner software driver, refer to AN 414: JRunner Software Driver: An Embedded Solution for PLD JTAG Configuration and the source files on the Altera website at (www.altera.com). Combining JTAG and AS Configuration Schemes You can combine the AS configuration scheme with JTAG-based configuration (Figure 8–22). This setup uses two 10-pin download cable headers on the board. One download cable is used in JTAG mode to configure the Cyclone IV device directly through the JTAG interface. The other download cable is used in AS mode to program the serial configuration device in-system through the AS programming interface. The MSEL pins must be set to select the AS configuration mode (refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7). If you try configuring the device using both schemes simultaneously, JTAG configuration takes precedence and AS configuration terminates. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–40 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Figure 8–22. Combining JTAG and AS Configuration Schemes VCCIO (1) VCCIO(1) VCCIO (1) 10 kΩ 10 kΩ 10 kΩ Cyclone IV Device Family VCCA nSTATUS CONF_DONE nCEO N.C. 10 kΩ nCONFIG nCE V Serial 10kΩ Configuration Device GND Pin 1 CCA 3.3 V 3.3 V 3.3 V 3.3 V (7) MSEL[3..0] (4) 10 kΩ (6) DATA DATA[0] TCK DCLK DCLK TDO nCS nCSO TMS ASDI ASDO TDI Download Cable (JTAG Mode) 10-Pin Male Header (top view) Pin 1 VCCA (5) VIO (3) 3.3 V (2) 1 kΩ 10 pf GND 10 pf 10 pf Download Cable (AS Mode) 10-Pin Male Header GND GND 10 pf (6) GND GND Notes to Figure 8–22: (1) Connect these pull-up resistors to the V CCIO supply of the bank in which the pin resides. (2) Power up the VCC of the ByteBlaster II or USB-Blaster cable with the 3.3-V supply. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the VCCA of the device. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. When using the ByteBlasterMV download cable, this pin is a no connect. When using the USB-Blaster and ByteBlaster II cables, this pin is connected to nCE when it is used for AS programming, otherwise it is a no connect. (4) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect MSEL for AS configuration schemes, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (5) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5-V supply from VCCA . Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (6) The diodes and capacitors must be placed as close as possible to the Cyclone IV device. Altera recommends using the Schottky diode, which has a relatively lower forward diode voltage (VF) than the switching and Zener diodes, for effective voltage clamping. (7) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–41 Programming Serial Configuration Devices In-System with the JTAG Interface Cyclone IV devices in a single- or multiple-device chain support in-system programming of a serial configuration device with the JTAG interface through the SFL design. The intelligent host or download cable of the board can use the four JTAG pins on the Cyclone IV device to program the serial configuration device in system, even if the host or download cable cannot access the configuration pins (DCLK, DATA, ASDI, and nCS pins). The SFL design is a JTAG-based in-system programming solution for Altera serial configuration devices. The SFL is a bridge design for the Cyclone IV device that uses its JTAG interface to access the EPCS JTAG Indirect Configuration Device Programming (.jic) file and then uses the AS interface to program the EPCS device. Both the JTAG interface and AS interface are bridged together inside the SFL design. In a multiple device chain, you must only configure the master device that controls the serial configuration device. Slave devices in the multiple device chain that are configured by the serial configuration device do not have to be configured when using this feature. To use this feature successfully, set the MSEL pins of the master device to select the AS configuration scheme (refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7). The serial configuration device in-system programming through the Cyclone IV device JTAG interface has three stages, which are described in the following sections: ■ “Loading the SFL Design” ■ “ISP of Configuration Device” on page 8–42 ■ “Reconfiguration” on page 8–42 Loading the SFL Design The SFL design is a design inside the Cyclone IV device that bridges the JTAG interface and AS interface with glue logic. The intelligent host uses the JTAG interface to configure the master device with an SFL design. The SFL design allows the master device to control the access of four serial configuration device pins, also known as the Active Serial Memory Interface (ASMI) pins, through the JTAG interface. The ASMI pins are serial clock input (DCLK), serial data output (DATA), AS data input (ASDI), and active-low chip select (nCS) pins. If you configure a master device with an SFL design, the master device enters user mode even though the slave devices in the multiple device chain are not being configured. The master device enters user mode with a SFL design even though the CONF_DONE signal is externally held low by the other slave devices in chain. Figure 8–23 shows the JTAG configuration of a single Cyclone IV device with a SFL design. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–42 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Figure 8–23. Programming Serial Configuration Devices In-System Using the JTAG Interface VCCA 10 kΩ VCCIO (1) VCCIO (1) VCCA 10 kΩ Cyclone IVDevice Family Serial Configuration VCCIO (1) Device 10 kΩ 10 kΩ DATA DCLK nCS ASDI 25 Ω (7) nCE (4) GND N.C. (5) (2) 10 kΩ TCK TDO nCEO nSTATUS CONF_DONE nCONFIG MSEL[3..0] (8) DATA[0] DCLK nCSO ASDO Download Cable 10-Pin Male Header (Top View) TMS TDI Serial Flash Loader Pin 1 VCCA (6) GND VIO (3) 1 kΩ GND GND Notes to Figure 8–23: (1) Connect the pull-up resistors to the VCCIO supply of the bank in which the pin resides. (2) The MSEL pin settings vary for different configuration voltage standards and POR time. To connect MSEL for AS configuration schemes, refer to Table 8–3 on page 8–7 and Table 8–4 on page 8–7. Connect the MSEL pins directly to VCCA or GND. (3) Pin 6 of the header is a VIO reference voltage for the MasterBlaster output driver. VIO must match the VCCA of the device. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. When using the ByteBlasterMV download cable, this pin is a no connect. When using USB-Blaster, ByteBlaster II, and Ethernet Blaster cables, this pin is connected to nCE when it is used for AS programming, otherwise it is a no connect. (4) The nCE pin must be connected to GND or driven low for successful JTAG configuration. (5) The nCEO pin is left unconnected or used as a user I/O pin when it does not feed the nCE pin of another device. (6) Power up the VCC of the ByteBlaster II, USB-Blaster, or ByteBlasterMV cable with a 2.5- V supply from VCCA . Third-party programmers must switch to 2.5 V. Pin 4 of the header is a VCC power supply for the MasterBlaster cable. The MasterBlaster cable can receive power from either 5.0- or 3.3-V circuit boards, DC power supply, or 5.0 V from the USB cable. For this value, refer to the MasterBlaster Serial/USB Communications Cable User Guide. (7) Connect the series resistor at the near end of the serial configuration device. (8) MSEL [3] is not applicable for EP4CGX15, EP4CGX22, and EP4CGX30 devices. ISP of Configuration Device In the second stage, the SFL design in the master device allows you to write the configuration data for the device chain into the serial configuration device with the Cyclone IV device JTAG interface. The JTAG interface sends the programming data for the serial configuration device to the Cyclone IV device first. The Cyclone IV device then uses the ASMI pins to send the data to the serial configuration device. Reconfiguration After the configuration data is successfully written into the serial configuration device, the Cyclone IV device does not start reconfiguration automatically. The intelligent host issues the PULSE_NCONFIG JTAG instruction to initialize the reconfiguration process. During reconfiguration, the master device is reset and the SFL design no longer exists in the Cyclone IV device and the serial configuration device configures all the devices in the chain with the user design. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration f 8–43 For more information about the SFL, refer to AN 370: Using the Serial FlashLoader with Quartus II Software. JTAG Instructions f For more information about the JTAG binary instruction code, refer to the JTAG Boundary-Scan Testing for Cyclone IV Devices chapter in volume 1 of the Cyclone IV Device Handbook. I/O Reconfiguration The CONFIG_IO instruction is used to reconfigure the I/O configuration shift register (IOCSR) chain. This instruction allows you to perform board-level testing prior to configuring the Cyclone IV device or waiting for a configuration device to complete configuration. After the configuration is interrupted and JTAG testing is complete, the part must be reconfigured through the PULSE_NCONFIG JTAG instruction or by pulsing nCONFIG pin low. You can issue the CONFIG_IO instruction any time during user mode. You must meet the following timing restrictions when using the CONFIG_IO instruction: ■ The CONFIG_IO instruction cannot be issued during nCONFIG pin low ■ You must observe 200 μs minimum wait time after any of the following conditions: ■ ■ nCONFIG pin goes high ■ Issuing PULSE_NCONFIG instruction ■ Issuing ACTIVE_ENGAGE instruction, before issuing CONFIG_IO instruction You must wait 200 μs after power up, with nCONFIG pin high before issuing CONFIG_IO instruction (or wait for nSTATUS pin goes high) The ACTIVE_DISENGAGE instruction is used with the CONFIG_IO instruction to interrupt configuration. Table 8–10 shows the sequence of instructions to use for various CONFIG_IO usage scenarios. Table 8–10. JTAG CONFIG_IO (without JTAG_PROGRAM) Instruction Flows (Part 1 of 2) (Note 1) Configuration Scheme and Current State of the Cyclone IV Device JTAG Instruction Prior to User Mode (Interrupting Configuration) User Mode Power Up PS FPP AS PS FPP AS PS FPP AS ACTIVE_DISENGAGE O O O O O O — — — CONFIG_IO R R R R R R NA NA NA JTAG Boundary Scan Instructions (no JTAG_PROGRAM) O O O O O O — — — R (2) — — — O — — — O — — — R (2) ACTIVE_ENGAGE PULSE_NCONFIG Pulse nCONFIG pin © November 2009 Altera Corporation A A A (3) A (3) A A Cyclone IV Device Handbook, Volume 1 8–44 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–10. JTAG CONFIG_IO (without JTAG_PROGRAM) Instruction Flows (Part 2 of 2) (Note 1) Configuration Scheme and Current State of the Cyclone IV Device JTAG Instruction JTAG TAP Reset Prior to User Mode (Interrupting Configuration) User Mode Power Up PS FPP AS PS FPP AS PS FPP AS R R R R R R — — — Notes to Table 8–10: (1) “R” indicates that the instruction is required to be executed before the next instruction, “O” indicates the optional instruction, “A” indicates that the instruction must be executed, and “NA” indicates that the instruction is not allowed to be executed in this mode. (2) Required if ACTIVE_DISENGAGE is used. (3) Neither of the instruction is required if ACTIVE_ENGAGE is used. The CONFIG_IO instruction does not hold nSTATUS low until reconfiguration. You must disengage the active configuration controller by issuing the ACTIVE_DISENGAGE and ACTIVE_ENGAGE instructions when active configuration is interrupted. You must issue the ACTIVE_DISENGAGE instruction alone or prior to the CONFIG_IO instruction, if the JTAG_PROGRAM instruction is to be issued later (refer to Table 8–11). This puts the active configuration controllers into the idle state. The active configuration controller is re-engaged after user mode is reached through JTAG programming (refer to Table 8–11). 1 While executing the CONFIG_IO instruction, all user I/Os are tri-stated. If reconfiguration after interruption is performed using configuration modes (rather than using JTAG_PROGRAM), it is not necessary to issue the ACTIVE_DISENGAGE instruction prior to CONFIG_IO. You can start reconfiguration by either pulling nCONFIG low for at least 500 ns or issuing the PULSE_NCONFIG instruction. If the ACTIVE_DISENGAGE instruction was issued and the JTAG_PROGRAM instruction fails to enter user mode, you must issue the ACTIVE_ENGAGE instruction to reactivate the active configuration controller. Issuing the ACTIVE_ENGAGE instruction also triggers reconfiguration in configuration modes; therefore, it is not necessary to pull nCONFIG low or issue the PULSE_NCONFIG instruction. ACTIVE_DISENGAGE The ACTIVE_DISENGAGE instruction places the active configuration controller into an idle state prior to JTAG programming. The two purposes of placing the active controller in an idle state are: ■ To ensure that it is not trying to configure the device during JTAG programming ■ To allow the controllers to properly recognize a successful JTAG programming that results in the device reaching user mode Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–45 The ACTIVE_DISENGAGE instruction is required before JTAG programming regardless of the current state of the Cyclone IV device if the MSEL pins are set to an active configuration scheme. If the ACTIVE_DISENGAGE instruction is issued during a passive configuration scheme (PS or FPP), it has no effect on the Cyclone IV device. Similarly, the CONFIG_IO instruction is issued after an ACTIVE_DISENGAGE instruction, but is no longer required to properly halt configuration. For a summary of the required, recommended, and optional instructions for each configuration mode, refer to Table 8–11. The ordering of the required instructions is a hard requirement and must be met to ensure functionality. Table 8–11. JTAG Programming Instruction Flows (Note 1) Configuration Scheme and Current State of the Cyclone IV Device JTAG Instruction Prior to User Mode (Interrupting Configuration) User Mode Power Up PS FPP AS PS FPP AS PS FPP AS FACTORY NA NA NA NA NA NA R R R ACTIVE_DISENGAGE O O R O O O O O R CONFIG_IO Rc Rc O O O O NA NA NA Other JTAG instructions O O O O O O O O O JTAG_PROGRAM R R R R R R R R R CHECK_STATUS Rc Rc Rc Rc Rc Rc Rc Rc Rc JTAG_STARTUP R R R R R R R R R JTAG TAP Reset/ other instruction R R R R R R R R R Note to Table 8–11: (1) “R” indicates that the instruction is required to be executed before the next instruction, “O” indicates the optional instruction, “Rc” indicates the recommended instruction, and “NA” indicates that the instruction is not allowed to be executed in this mode. In the AS configuration scheme, the ACTIVE_DISENGAGE instruction puts the active configuration controller into idle state. If a successful JTAG programming is executed, the active controller is automatically re-engaged after user mode is reached through JTAG programming. This causes the active controller to transition to their respective user mode states. If JTAG programming fails to get the Cyclone IV device to enter user mode and re-engage active programming, there are available methods to achieve this scheme. In AS configuration scheme, you can re-engage the AS controller by moving the JTAG TAP controller to the reset state, or by issuing the ACTIVE_ENGAGE instruction. ACTIVE_ENGAGE The ACTIVE_ENGAGE instruction enables you to re-engage a disengaged active controller. You can issue this instruction any time during configuration or user mode to re-engage an already disengaged active controller, as well as trigger reconfiguration of the Cyclone IV device in the active configuration scheme. The ACTIVE_ENGAGE instruction functions as the PULSE_NCONFIG instruction when the device is in the passive configuration schemes (PS or FPP). The nCONFIG pin is disabled when the ACTIVE_ENGAGE instruction is issued. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–46 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 1 Altera does not recommend using the ACTIVE_ENGAGE instruction, but it is provided as a fail-safe instruction for re-engaging the active configuration controller. Device Configuration Pins Table 8–12 to Table 8–14 describe the connections and functionality of all the configuration related pins on Cyclone IV devices. Table 8–12 summarizes the Cyclone IV device pin configuration. Table 8–12. Cyclone IV Configuration Pin Summary Bank Description Input/Output Dedicated Powered By Configuration Mode 8 Data[4:2] Input — VCC IO FPP 3 Data[7:5] Input — VCC IO FPP 9 nCSO Output — VCC IO AS 3 CRC_ERROR Output — VCC IO /Pull-up (1) Optional, all modes 9 DATA[0] Input Yes VCC IO PS, FPP, AS 9 DATA[1], ASDO VCC IO FPP VCC IO AS 3 INIT_DONE — Pull-up Optional, all modes 3 nSTATUS Bidirectional Yes Pull-up All modes 9 nCE Input Yes VCC IO All modes 9 DCLK VCC IO PS, FPP VCC IO AS 3 CONF_DONE 9 Input Output Output Input Output — Yes Bidirectional Yes Pull-up All modes TDI Input Yes VCC IO JTAG 9 TMS Input Yes VCC IO JTAG 9 TCK Input Yes VCC IO JTAG 9 nCONFIG Input Yes VCC IO All modes 8 CLKUSR Input — VCC IO Optional 3 nCEO Output — VCC IO Optional, all modes 3 MSEL Input Yes VC CINT All modes 9 TDO Output Yes VCC IO JTAG 6 DEV_OE Input — VCC IO Optional 6 DEV_CLRn Input — VCC IO Optional Note to Table 8–12: (1) The CRC_ERROR pin is a dedicated output by default. Optionally, you can enable the CRC_ERROR pin as an open-drain output in the CRC Error Detection tab of the Device and Pin Options dialog box. Table 8–13 describes the dedicated configuration pins, which are required to be connected properly on your board for successful configuration. Some of these pins may not be required for your configuration schemes. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–47 Table 8–13. Dedicated Configuration Pins on the Cyclone IV Device (Part 1 of 3) User Mode Configuration Scheme Pin Type Description MSEL N/A All Input Configuration input that sets the Cyclone IV device configuration scheme. These pins must be hardwired to VCC A or GND. The MSEL pins have internal 9-kΩ pull-down resistors that are always active. nCONFIG N/A All Input Configuration control input. Pulling this pin low with external circuitry during user mode causes the Cyclone IV device to lose its configuration data, enter a reset state, and tri-state all I/O pins. Returning this pin to a logic-high level starts a reconfiguration. nSTATUS N/A All Pin Name Bidirectional The Cyclone IV device drives nSTATUS low immediately after open-drain power-up and releases it after the POR time. Status output. If an error occurs during configuration, nSTATUS is pulled low by the target device. Status input. If an external source (for example, another Cyclone IV device) drives the nSTATUS pin low during configuration or initialization, the target device enters an error state. Driving nSTATUS low after configuration and initialization does not affect the configured device. If a configuration device is used, driving nSTATUS low causes the configuration device to attempt to configure the device, but because the device ignores transitions on nSTATUS in user mode, the device does not reconfigure. To start a reconfiguration, nCONFIG must be pulled low. CONF_DONE N/A All Bidirectional Status output. The target Cyclone IV device drives the open-drain CONF_DONE pin low before and during configuration. After all configuration data is received without error and the initialization cycle starts, the target device releases CONF_DONE. Status input. After all data is received and CONF_DONE goes high, the target device initializes and enters user mode. The CONF_DONE pin must have an external 10-kΩ pull-up resistor in order for the device to initialize. Driving CONF_DONE low after configuration and initialization does not affect the configured device. Do not connect bus holds or ADC to CONF_DONE pin. nCE N/A © November 2009 Altera Corporation All Input Active-low chip enable. The nCE pin activates the Cyclone IV device with a low signal to allow configuration. The nCE pin must be held low during configuration, initialization, and user-mode. In single-device configuration, it must be tied low. In multi-device configuration, nCE of the first device is tied low while its nCEO pin is connected to nCE of the next device in the chain. The nCE pin must also be held low for successful JTAG programming of the device. Cyclone IV Device Handbook, Volume 1 8–48 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–13. Dedicated Configuration Pins on the Cyclone IV Device (Part 2 of 3) Pin Name nCEO User Mode Configuration Scheme N/A if option is on. I/O if option is off. All Pin Type Description Output open-drain Output that drives low when the Cyclone IV device configuration is complete. In single-device configuration, you can leave this pin floating or use it as a user I/O pin after configuration. In multi-device configuration, this pin feeds the nCE pin of the next device. The nCEO of the last device in the chain is left floating or used as a user I/O pin after configuration. If you use the nCEO pin to feed the nCE pin of the next device, use an external 10-kΩ pull-up resistor to pull the nCEO pin high to the VCC IO voltage of its I/O bank to help the internal weak pull-up resistor. If you use the nCEO pin as a user I/O pin after configuration, set the state of the pin on the Dual-Purpose Pin settings. nCSO I/O AS DCLK N/A All Output Output control signal from the Cyclone IV device to the serial configuration device in AS mode that enables the configuration device. This pin has an internal pull-up resistor that is always active. Input (PS, In PS and FPP configuration, DCLK is the clock input used to clock data from an external source into the target Cyclone IV FPP). Output (AS) device. Data is latched into the device on the rising edge of DCLK. In AS mode, DCLK is an output from the Cyclone IV device that provides timing for the configuration interface. It has an internal pull-up resistor (typically 25 kΩ) that is always active. After configuration, this pin is tri-stated. In schemes that use a configuration device, DCLK is driven low after configuration is complete. In schemes that use a control host, DCLK must be driven either high or low, whichever is more convenient. Toggling this pin after configuration does not affect the configured device DATA[0] I/O All Input Data input. In serial configuration modes, bit-wide configuration data is presented to the target Cyclone IV device on the DATA[0] pin. In AS mode, DATA[0] has an internal pull-up resistor that is always active. After AS configuration, DATA[0] is a dedicated input pin with optional user control. After PS or FPP configuration, DATA[0] is available as a user I/O pin and the state of this pin depends on the Dual-Purpose Pin settings. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration 8–49 Table 8–13. Dedicated Configuration Pins on the Cyclone IV Device (Part 3 of 3) Pin Name DATA[1], ASDO User Mode Configuration Scheme I/O FPP, AS Pin Type Description Input (FPP), Data input in non-AS mode. Control signal from the Cyclone IV Output (AS) device to the serial configuration device in AS mode used to read out configuration data. The DATA[1] pin functions as the ASDO pin in AS mode. In AS mode, DATA[1] has an internal pull-up resistor that is always active. After AS configuration, DATA[1] is a dedicated output pin with optional user control. In PS configuration scheme, DATA[1] functions as user I/O pin during configuration, which means it is tri-stated. After FPP configuration, DATA[1] is available as a user I/O pin and the state of this pin depends on the Dual-Purpose Pin settings. DATA[7..2] I/O FPP Inputs Data inputs. In AS or PS configuration scheme, they function as user I/O pins during configuration, which means they are tri-stated. After FPP configuration, DATA[7..2] are available as user I/O pins and the state of these pin depends on the Dual-Purpose Pin settings. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–50 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Configuration Table 8–14 describes the optional configuration pins. If these optional configuration pins are not enabled in the Quartus II software, they are available as general-purpose user I/O pins. Therefore, during configuration, these pins function as user I/O pins and are tri-stated with weak pull-up resistors. Table 8–14. Optional Configuration Pins Pin Name User Mode Pin Type Description CLKUSR N/A if option is on. I/O if option is off. Input Optional user-supplied clock input synchronizes the initialization of one or more devices. This pin is enabled by turning on the Enable user-supplied start-up clock (CLKUSR) option in the Quartus II software. INIT_DONE N/A if option is on. I/O if option is off. Output open-drain Status pin is used to indicate when the device has initialized and is in user-mode. When nCONFIG is low, the INIT_DONE pin is tri-stated and pulled high due to an external 10-kΩ pull-up resistor during the beginning of configuration. After the option bit to enable INIT_DONE is programmed into the device (during the first frame of configuration data), the INIT_DONE pin goes low. When initialization is complete, the INIT_DONE pin is released and pulled high and the device enters user mode. Thus, the monitoring circuitry must be able to detect a low-to-high transition. This pin is enabled by turning on the Enable INIT_DONE output option in the Quartus II software. The functionality of this pin changes if the Enable OCT_DONE option is enabled in the Quartus II software. This option controls whether the INIT_DONE signal is gated by the OCT_DONE signal, which indicates the Power-Up on-chip termination (OCT) calibration is completed. If this option is turned off, the INIT_DONE signal is not gated by the OCT_DONE signal DEV_OE N/A if option is on. I/O if option is off. Input Optional pin that allows you to override all tri-states on the device. When this pin is driven low, all I/O pins are tri-stated; when this pin is driven high, all I/O pins behave as programmed. This pin is enabled by turning on the Enable device-wide output enable (DEV_OE) option in the Quartus II software. DEV_CLRn N/A if option is on. I/O if option is off. Input Optional pin that allows you to override all clears on all device registers. When this pin is driven low, all registers are cleared; when this pin is driven high, all registers behave as programmed. This pin is enabled by turning on the Enable device-wide reset (DEV_CLRn) option in the Quartus II software. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade 8–51 Remote System Upgrade Cyclone IV devices support remote system upgrade only in AS configuration scheme and can also be implemented with advanced Cyclone IV features such as real-time decompression of configuration data. 1 Remote system upgrade is not supported in multi-device configuration chain for any configuration scheme. Functional Description The dedicated remote system upgrade circuitry in Cyclone IV devices manages remote configuration and provides error detection, recovery, and status information. User logic or a Nios® II processor implemented in the Cyclone IV device logic array provides access to the remote configuration data source and an interface to the configuration memory. 1 Configuration memory refers to serial configuration devices (EPCS). The remote system upgrade process of the Cyclone IV device consists of the following steps: 1. A Nios II processor (or user logic) implemented in the Cyclone IV device logic array receives new configuration data from a remote location. The connection to the remote source is a communication protocol, such as the transmission control protocol/Internet protocol (TCP/IP), peripheral component interconnect (PCI), user datagram protocol (UDP), universal asynchronous receiver/transmitter (UART), or a proprietary interface. 2. The Nios II processor (or user logic) writes this new configuration data into a configuration memory. 3. The Nios II processor (or user logic) starts a reconfiguration cycle with the new or updated configuration data. 4. The dedicated remote system upgrade circuitry detects and recovers from any error that might occur during or after the reconfiguration cycle, and provides error status information to the user design. Figure 8–24 shows the steps required for performing remote configuration updates (the numbers in Figure 8–24 coincide with steps 1–3). Figure 8–24. Functional Diagram of Cyclone IV Device Remote System Upgrade 1 2 Development Location Data Data Configuration Memory Cyclone IV Device Family Control Module Data Device Configuration 3 Figure 8–25 shows the block diagrams to implement remote system upgrade. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–52 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade Figure 8–25. Remote System Upgrade Block Diagrams Serial Configuration Device Cyclone IV Device Nios Processor or User Logic Serial Configuration Device The MSEL pin setting in the remote system upgrade mode is the same as the standard configuration mode. Standard configuration mode refers to normal Cyclone IV device configuration mode with no support for remote system upgrades, and the remote system upgrade circuitry is disabled. When using remote system upgrade in Cyclone IV devices, you must enable the remote update mode option setting in the Quartus II software. For more information, refer to “Enabling Remote Update”. Enabling Remote Update You can enable or disable remote update for Cyclone IV devices in the Quartus II software before design compilation (in the Compiler Settings menu). To enable remote update in the compiler settings of the project, perform the following steps: 1. On the Assignments menu, click Device. The Device dialog box appears. 2. Click Device and Pin Options. The Device and Pin Options dialog box appears. 3. In the Category list, select Configuration. 4. In the Configuration Mode list, select Remote. 5. Click OK. 6. In the Device dialog box, click OK. Configuration Image Types When using remote system upgrade, Cyclone IV device configuration bitstreams are classified as factory configuration images or application configuration images. An image, also referred to as a configuration, is a design loaded into the device that performs certain user-defined functions. Each device in your system requires one factory image or with addition of one or more application images. The factory image is a user-defined fall-back (or safe) configuration and is responsible for administering remote updates with the dedicated circuitry. Application images implement user-defined functionality in the target Cyclone IV device. You can include the default application image functionality in the factory image. Remote System Upgrade Mode In remote update mode, Cyclone IV devices load the factory configuration image upon power-up. The user-defined factory configuration determines the application configuration to be loaded and triggers a reconfiguration cycle. The factory configuration can also contain application logic. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade 8–53 When used with configuration memory, the remote update mode allows an application configuration to start at any flash sector boundary. Additionally, the remote update mode features a user watchdog timer that can detect functional errors in an application configuration. Remote Update Mode When a Cyclone IV device is first powered up in remote update mode, it loads the factory configuration located at address boot_address[23:0] = 24b'0. Altera recommends storing the factory configuration image for your system at boot address 24b'0. This corresponds to the start address location 0x000000 in the serial configuration device. The factory image is user designed and contains soft logic to: ■ Process any errors based on status information from the dedicated remote system upgrade circuitry ■ Communicate with the remote host and receive new application configurations, and store the new configuration data in the local non-volatile memory device ■ Determine the application configuration to be loaded into the Cyclone IV device ■ Enable or disable the user watchdog timer and load its time-out value (optional) ■ Instruct the dedicated remote system upgrade circuitry to start a reconfiguration cycle Figure 8–26 shows the transitions between the factory configuration and application configuration in remote update mode. Figure 8–26. Transitions Between Configurations in Remote Update Mode Configuration Error Power Up Application 1 Configuration Set Control Register and Reconfigure Reload a Different Application Configuration Error Factory Configuration Reload a Different Application Set Control Register and Reconfigure Application n Configuration Configuration Error © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–54 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade After power up or a configuration error, the factory configuration logic writes the remote system upgrade control register to specify the address of the application configuration to be loaded. The factory configuration also specifies whether or not to enable the user watchdog timer for the application configuration and, if enabled, specifies the timer setting. 1 Only valid application configurations designed for remote update mode include the logic to reset the timer in user mode. For more information about the user watchdog timer, refer to the “User Watchdog Timer” on page 8–59. If there is an error while loading the application configuration, the remote system upgrade status register is written by the dedicated remote system upgrade circuitry of the Cyclone IV device to specify the cause of the reconfiguration. The following actions cause the remote system upgrade status register to be written: ■ nSTATUS driven low externally ■ Internal CRC error ■ User watchdog timer time-out ■ A configuration reset (logic array nCONFIG signal or external nCONFIG pin assertion) Cyclone IV devices automatically load the factory configuration located at address boot_address[23:0] = 24'b0. This user-designed factory configuration reads the remote system upgrade status register to determine the reason for reconfiguration. The factory configuration takes the appropriate error recovery steps and writes to the remote system upgrade control register to determine the next application configuration to be loaded. When Cyclone IV devices successfully load the application configuration, they enter user mode. In user mode, the soft logic (Nios II processor or state machine and the remote communication interface) assists the Cyclone IV device in determining when a remote system update is arriving. When a remote system update arrives, the soft logic receives the incoming data, writes it to the configuration memory device, and triggers the device to load the factory configuration. The factory configuration reads the remote system upgrade status register, determines the valid application configuration to load, writes the remote system upgrade control register accordingly, and starts system reconfiguration. Dedicated Remote System Upgrade Circuitry This section explains the implementation of the Cyclone IV device remote system upgrade dedicated circuitry. The remote system upgrade circuitry is implemented in hard logic. This dedicated circuitry interfaces with the user-defined factory application configurations implemented in the Cyclone IV device logic array to provide the complete remote configuration solution. The remote system upgrade circuitry contains the remote system upgrade registers, a watchdog timer, and state machines that control those components. Figure 8–27 shows the data path of the remote system upgrade block. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade 8–55 Figure 8–27. Remote System Upgrade Circuit Data Path (Note 1) Status Register (SR) Previous State Register 2 Bit[30..0] Internal Oscillator Current State Logic Bit[31..0] Previous State Register 1 Bit[30..0] Control Register Bit [38..0] Logic Update Register Bit [38..0] update RSU Master State Machine Logic Shift Register din dout din Bit [40..39] dout Bit [38..0] RU_SHIFTnLD timeout User Watchdog Timer capture clkout RU_DIN RSU Reconfiguration State Machine capture update Logic clkin RU_CLK (2) RU_DOUT RU_CAPTnUPDT RU_nCONFIG RU_nRSTIMER Logic Array Notes to Figure 8–27: (1) RU_DOUT, RU_SHIFTnLD, RU_CAPTnUPDT, RU_CLK, RU_DIN,RU_nCONFIG, and RU_nRSTIMER signals are internally controlled by the ALTREMOTE_UPDATE megafunction. (2) RU_CLK refers to the ALTREMOTE_UPDATE megafunction block "clock" input. For more information, refer to the Remote Update Circuitry (ALTREMOTE_UPDATE) Megafunction User Guide. Remote System Upgrade Registers The remote system upgrade block contains a series of registers that stores the configuration addresses, watchdog timer settings, and status information. These registers are described in Table 8–15. Table 8–15. Remote System Upgrade Registers (Part 1 of 2) Register Description Shift register This register is accessible by the logic array and allows the update, status, and control registers to be written and sampled by user logic. Write access is enabled in remote update mode for factory configurations to allow writing to the update register. Write access is disabled for all application configurations in remote update mode. Control register This register contains the current configuration address, the user watchdog timer settings, one option bit for checking early CONF_DONE, and one option bit for selecting the internal oscillator as the startup state machine clock. During a read operation in an application configuration, this register is read into the shift register. When a reconfiguration cycle is started, the contents of the update register are written into the control register. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–56 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade Table 8–15. Remote System Upgrade Registers (Part 2 of 2) Register Description Update register This register contains data similar to that in the control register. However, it can only be updated by the factory configuration by shifting data into the shift register and issuing an update operation. When a reconfiguration cycle is triggered by the factory configuration, the control register is updated with the contents of the update register. During a read in a factory configuration, this register is read into the shift register. Status register This register is written by the remote system upgrade circuitry on every reconfiguration to record the cause of the reconfiguration. This information is used by the factory configuration to determine the appropriate action following a reconfiguration. During a capture cycle, this register is read into the shift register. The control and status registers of the remote system upgrade are clocked by the 10-MHz internal oscillator (the same oscillator that controls the user watchdog timer). However, the shift and update registers of the remote system upgrade are clocked by the maximum frequency of 40-MHz user clock input (RU_CLK). There is no minimum frequency for RU_CLK. Remote System Upgrade Control Register The remote system upgrade control register stores the application configuration address, the user watchdog timer settings, and option bits for application configuration. The control register address bits are set to all zeros (24'b0) at power up to load the factory configuration. The control register bit positions are shown in Figure 8–28 and defined in Table 8–16. In Figure 8–28, the numbers show the bit position of a setting in a register. For example, bit number 35 is the enable bit for the watchdog timer. Figure 8–28. Remote System Upgrade Control Register 38 Rsv2 37 36 35 34 33 12 11 0 Cd_early Osc_int Wd_en Rsv1 Ru_address[21..0] Wd_timer[11..0] Table 8–16. Remote System Upgrade Control Register Contents Control Register Bit Value Wd_timer[11..0] 12'b000000000000 Definition User watchdog time-out value (most significant 12 bits of 29-bit count value: {Wd_timer[11..0],17'b1000}) Configuration address (most significant 22 bits of 24-bit boot address value: Ru_address[21..0] 22'b0000000000000000000000 boot_address[23:0] = {Ru_address[21..0],2'b0}) Rsv1 1'b0 Reserved bit Wd_en 1'b1 User watchdog timer enable bit Osc_int (1) 1'b1 Internal oscillator as startup state machine clock enable bit Cd_early (1) 1'b1 Early CONF_DONE check Rsv2 1'b1 Reserved bit Note to Table 8–16: (1) Option bit for the application configuration. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade 8–57 When enabled, the early CONF_DONE check (Cd_early) option bit ensures that there is a valid configuration at the boot address specified by the factory configuration and that it is of the proper size. If an invalid configuration is detected or the CONF_DONE pin is asserted too early, the device resets and then reconfigures the factory configuration image. When enabled, the internal oscillator (as the startup state machine clock [Osc_int] option bit) ensures a functional startup clock to eliminate the hanging of startup. When all option bits are turned on, they provide complete coverage for the programming and startup portions of the application configuration. Altera recommends turning on both the Cd_early and Osc_int option bits. 1 The Cd_early and Osc_int option bits for the application configuration must be turned on by the factory configuration. Remote System Upgrade Status Register The remote system upgrade status register specifies the reconfiguration trigger condition. The various trigger and error conditions include: ■ Cyclical redundancy check (CRC) error during application configuration ■ nSTATUS assertion by an external device due to an error ■ Cyclone IV device logic array triggers a reconfiguration cycle, possibly after downloading a new application configuration image ■ External configuration reset (nCONFIG) assertion ■ User watchdog timer time out Table 8–17 describes the contents of the current state logic in the status register, when the remote system upgrade master state machine is in factory configuration or application configuration accessing the factory information or application information, respectively. The status register bit in Table 8–17 shows the bit positions in a 32-bit logic. Table 8–17. Remote System Upgrade Current State Logic Contents In Status Register (Part 1 of 2) Remote System Upgrade Master State Machine Factory information (1) Application information 1 (2) © November 2009 Altera Corporation Status Register Bit Definition 31:30 Master State Machine current state The current state of the remote system upgrade master state machine 29:24 Reserved bits Padding bits that are set to all 0’s 23:0 Boot address The current 24-bit boot address that was used by the configuration scheme as the start address to load the current configuration. 31:30 Master State Machine current state The current state of the remote system upgrade master state machine 29 User watchdog timer enable bit The current state of the user watchdog enable, which is active high 28:0 User watchdog timer time-out value The current entire 29-bit watchdog time-out value. Description Cyclone IV Device Handbook, Volume 1 8–58 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade Table 8–17. Remote System Upgrade Current State Logic Contents In Status Register (Part 2 of 2) Remote System Upgrade Master State Machine Status Register Bit Definition 31:30 Master State Machine current state The current state of the remote system upgrade master state machine 29 User watchdog timer enable bit The current state of the user watchdog enable, which is active high 28:0 User watchdog timer time-out value The current entire 29-bit watchdog time-out value Application information 2 (2) Description Notes to Table 8–17 (1) The remote system upgrade master state machine is in factory configuration. (2) The remote system upgrade master state machine is in application configuration. The previous two application configurations are available in the previous state registers (previous state register 1 and previous state register 2), but only for debugging purposes. Table 8–18 describes the contents of previous state register 1 and previous state register 2 in the status register. The status register bit in Table 8–18 shows the bit positions in a 31-bit register. Previous state register 1 has the same bit definitions as previous state register 2, except all fields reflect the current state when a reconfiguration source caused the Cyclone IV device to leave the application configuration before the previous application configuration. Table 8–18. Remote System Upgrade Previous State Register 1 and Previous State Register 2 Contents in Status Register (Note 1) Status Register Bit Definition 30 nCONFIG source 29 CRC error source 28 nSTATUS source 27 User watchdog timer source 26 Remote system upgrade nCONFIG source 25:24 23:0 Description One-hot, active-high field that describes the reconfiguration source that caused the Cyclone IV device to leave the previous application configuration. If there is a tie, the higher bit order indicates precedence. For example, if nCONFIG and remote system upgrade nCONFIG reach the reconfiguration state machine at the same time, the nCONFIG precedes the remote system upgrade nCONFIG. Master state machine current state The state of the master state machine during reconfiguration causes the Cyclone IV device to leave the previous application configuration. Boot address The address used by the configuration scheme to load the previous application configuration. Note to Table 8–18: (1) Bit definitions are the same as previous state register 1, except all fields reflect the current state when a reconfiguration source caused the Cyclone IV device to leave the application configuration before the previous application configuration. If a capture is inappropriately done while capturing a previous state before the system has entered remote update application configuration for the first time, a value will output from the shift register to indicate that the capture was incorrectly called. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Remote System Upgrade 8–59 Remote System Upgrade State Machine The remote system upgrade control and update registers have identical bit definitions, but serve different roles (for more information, refer to Table 8–15 on page 8–55). While both registers can only be updated when the device is loaded with a factory configuration image, the update register writes are controlled by the user logic, and the control register writes are controlled by the remote system upgrade state machine. In factory configurations, the user logic should send the option bits (Cd_early and Osc_int), the configuration address, and watchdog timer settings for the next application configuration bit to the update register. When the logic array configuration reset (RU_nCONFIG) goes high, the remote system upgrade state machine updates the control register with the contents of the update register and starts system reconfiguration from the new application page. 1 To ensure the successful reconfiguration between the pages, assert the RU_nCONFIG signal for a minimum of 250 ns. This is equivalent to strobing the reconfig input of the ALTREMOTE_UPDATE megafunction high for a minimum of 250 ns. If there is an error or reconfiguration trigger condition, the remote system upgrade state machine directs the system to load a factory or application configuration (based on mode and error condition) by setting the control register accordingly. Table 8–19 lists the contents of the control register after such an event occurs for all possible error or trigger conditions. The remote system upgrade status register is updated by the dedicated error monitoring circuitry after an error condition, but before the factory configuration is loaded. Table 8–19. Control Register Contents After an Error or Reconfiguration Trigger Condition Reconfiguration Error/Trigger Control Register Setting In Remote Update nCONFIG reset All bits are 0 nSTATUS error All bits are 0 CORE triggered reconfiguration Update register CRC error All bits are 0 Wd time out All bits are 0 User Watchdog Timer The user watchdog timer prevents a faulty application configuration from stalling the device indefinitely. The system uses the timer to detect functional errors after an application configuration is successfully loaded into the Cyclone IV device. The user watchdog timer is a counter that counts down from the initial value loaded into the remote system upgrade control register by the factory configuration. The counter is 29 bits wide and has a maximum count value of 229. When specifying the user watchdog timer value, specify only the most significant 12 bits. The remote system upgrade circuitry appends 17'b1000 to form the 29 bits value for the watchdog timer. The granularity of the timer setting is 217 cycles. The cycle time is based on the frequency of the 10-MHz internal oscillator. Table 8–20 specifies the operating range of the 10-MHz internal oscillator. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 8–60 Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices Chapter Revision History Table 8–20. 10-MHz Internal Oscillator Specifications Minimum Typical Maximum Unit 5 6.5 10 MHz The user watchdog timer begins counting after the application configuration enters device user mode. This timer must be periodically reloaded or reset by the application configuration before the timer expires by asserting RU_nRSTIMER. If the application configuration does not reload the user watchdog timer before the count expires, a time-out signal is generated by the remote system upgrade dedicated circuitry. The time-out signal tells the remote system upgrade circuitry to set the user watchdog timer status bit (Wd) in the remote system upgrade status register and reconfigures the device by loading the factory configuration. 1 To allow the remote system upgrade dedicated circuitry to reset the watchdog timer, you must assert the RU_nRSTIMER signal active for a minimum of 250 ns. This is equivalent to strobing the reset_timer input of the ALTREMOTE_UPDATE megafunction high for a minimum of 250 ns. Errors during configuration are detected by the CRC engine. Functional errors must not exist in the factory configuration because it is stored and validated during production and is never updated remotely. 1 The user watchdog timer is disabled in factory configurations and during the configuration cycle of the application configuration. It is enabled after the application configuration enters user mode. Quartus II Software Support Implementation in your design requires a remote system upgrade interface between the Cyclone IV device logic array and remote system upgrade circuitry. You must also generate configuration files for production and remote programming of the system configuration memory. The Quartus II software provides these features. The two implementation options, ALTREMOTE_UPDATE megafunction and remote system upgrade atom, are for the interface between the remote system upgrade circuitry and the device logic array interface. Using the megafunction block instead of creating your own logic saves design time and offers more efficient logic synthesis and device implementation. f For more information about the ALTREMOTE_UPDATE megafunction, refer to the Remote Update Circuitry (ALTREMOTE_UPDATE) Megafunction User Guide. Chapter Revision History Table 8–21 shows the revision history for this chapter. Table 8–21. Chapter Revision History Date Version November 2009 Cyclone IV Device Handbook, Volume 1 1.0 Changes Made Initial release. © November 2009 Altera Corporation 9. SEU Mitigation in Cyclone IV Devices CYIV-51009-1.0 This chapter describes the error detection cyclical redundancy check (CRC) feature in the user mode and describes how to recover from configuration errors caused by CRC error. 1 References to Cyclone® IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. Dedicated circuitry built into Cyclone IV devices consist of a CRC error detection feature that can optionally check for a single-event upset (SEU) continuously and automatically. In critical applications used in the fields of avionics, telecommunications, system control, medical, and military applications, it is important to be able to: ■ Confirm the accuracy of the configuration data stored in an FPGA device ■ Alert the system to an occurrence of a configuration error Using the CRC error detection feature for Cyclone IV devices does not impact fitting or performance. This chapter contains the following sections: ■ “Configuration Error Detection” on page 9–1 ■ “User Mode Error Detection” on page 9–2 ■ “Automated SEU Detection” on page 9–3 ■ “CRC_ERROR Pin” on page 9–3 ■ “Error Detection Block” on page 9–4 ■ “Error Detection Timing” on page 9–5 ■ “Software Support” on page 9–7 ■ “Recovering from CRC Errors” on page 9–10 Configuration Error Detection Configuration error detection determines if the configuration data received through an external memory device is corrupted during configuration. To validate the configuration data, the Quartus ® II software uses a function to calculate the CRC value for each configuration data frame and store the frame-based CRC value in the configuration data as part of the configuration bit stream. During configuration, Cyclone IV devices use the same methodology to calculate the CRC value based on the frame of data that is received and compares it against the frame CRC value in the data stream. Configuration continues until either the device detects an error or all the values are calculated. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 9–2 Chapter 9: SEU Mitigation in Cyclone IV Devices User Mode Error Detection In addition to the frame-based CRC value, the Quartus II software generates a 32-bit CRC value for the whole configuration bit stream. This 32-bit CRC value is stored in the 32-bit storage register at the end of the configuration and is used for user mode error detection that will be discussed in “User Mode Error Detection” section. User Mode Error Detection Soft errors are changes in a configuration random-access memory (CRAM) bit state due to an ionizing particle. Cyclone IV devices have built-in error detection circuitry to detect data corruption by soft errors in the CRAM cells. This error detection capability continuously computes the CRC of the configured CRAM bits based on the contents of the device and compares it with the pre-calculated CRC value obtained at the end of the configuration. If the CRCs match, there is no error in the current configuration CRAM bits. The process of error detection continues until the device is reset (by setting nCONFIG to low). Cyclone IV devices error detection feature does not check memory blocks and I/O buffers. These device memory blocks support parity bits that are used to check the contents of memory blocks for any error. The I/O buffers are not verified during error detection because the configuration data uses flip-flops as storage elements that are more resistant to soft errors. Similar flip-flops are used to store the pre-calculated CRC and other error detection circuitry option bits. The error detection circuitry in Cyclone IV devices uses a 32-bit CRC IEEE 802 standard and a 32-bit polynomial as the CRC generator. Therefore, a single 32-bit CRC calculation is performed by the device. If a soft error does not occur, the resulting 32-bit signature value is 0x00000000, that results in a 0 on the output signal CRC_ERROR. If a soft error occurs in the device, the resulting signature value is non-zero and the CRC_ERROR output signal is 1. You can inject a soft error by changing the 32-bit CRC storage register in the CRC circuitry. After verifying the failure induced, you can restore the 32-bit CRC value to the correct CRC value using the same instruction and inserting the correct value. 1 Be sure to read out the correct value before updating it with a known bad value. In user mode, Cyclone IV devices support the CHANGE_EDREG JTAG instruction, that allows you to write to the 32-bit storage register. You can use Jam ™ STAPL files (.jam) to automate the testing and verification process. This instruction can only be executed when the device is in user mode, and it is a powerful design feature that enables you to dynamically verify the CRC functionality in-system without having to reconfigure the device. You can then switch to use the CRC circuit to check for real errors induced by an SEU. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 9: SEU Mitigation in Cyclone IV Devices Automated SEU Detection 9–3 Table 9–1 lists the CHANGE_EDREG JTAG instructions. Table 9–1. CHANGE_EDREG JTAG Instruction JTAG Instruction Instruction Code Description CHANGE_EDREG 00 0001 0101 This instruction connects the 32-bit CRC storage register between TDI and TDO. Any precomputed CRC is loaded into the CRC storage register to test the operation of the error detection CRC circuitry at the CRC_ERROR pin. 1 After the test completes, Altera recommends that you power cycle the device. Automated SEU Detection Cyclone IV devices offer on-chip circuitry for automated checking of SEU detection. Applications that require the device to operate error-free at high elevations or in close proximity to earth’s North or South Pole require periodic checks to ensure continued data integrity. The error detection cyclic redundancy code feature controlled by the Device and Pin Options dialog box in the Quartus II software uses a 32-bit CRC circuit to ensure data reliability and is one of the best options for mitigating SEU. You can implement the error detection CRC feature with existing circuitry in Cyclone IV devices, eliminating the need for external logic. The CRC is computed by the device during configuration and checked against an automatically computed CRC during normal operation. The CRC_ERROR pin reports a soft error when configuration CRAM data is corrupted, and you must decide whether to reconfigure the FPGA by strobing the nCONFIG pin low or ignore the error. CRC_ERROR Pin A specific CRC_ERROR error detection pin is required to monitor the results of the error detection circuitry during user mode. Table 9–2 describes the CRC_ERROR pin. Table 9–2. CRC_ERROR Pin Description CRC_ERROR Pin Type Device Cyclone IV Dedicated Output or Open Drain Output (Optional) Description By default, the Quartus II software sets the CRC_ERROR pin as a dedicated output. If the CRC_ERROR pin is used as a dedicated output, you must ensure that the VCCIO of the bank in which the pin resides meets the input voltage specification of the system receiving the signal. Optionally, you can set this pin to be an open-drain output by enabling the option in the Quartus II software from the Error Detection CRC tab of the Device and Pin Options dialog box. Using the pin as an open-drain provides an advantage on the voltage leveling. To use this pin as open-drain, you can tie this pin to VCCIO of Bank 1 through a 10-kΩ pull-resistor. Alternatively, depending on the voltage input specification of the system receiving the signal, you can tie the pull-up resistor to a different pull-up voltage. f The CRC_ERROR pin information for Cyclone IV devices is reported in the Cyclone IV Devices Pin-Outs on the Altera ® website. 1 WYSIWYG is an optimization technique that performs optimization on VQM (Verilog Quartus Mapping) netlist in the Quartus II software. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 9–4 Chapter 9: SEU Mitigation in Cyclone IV Devices Error Detection Block Error Detection Block Table 9–3 lists the types of CRC detection to check the configuration bits. Table 9–3. Types of CRC Detection to Check the Configuration Bits First Type of CRC Detection ■ ■ CRAM error checking ability (32-bit CRC) during user mode, for use by the CRC_ERROR pin. There is only one 32-bit CRC value, and this value covers all the CRAM data. Second Type of CRC Detection ■ 16-bit CRC embedded in every configuration data frame. ■ During configuration, after a frame of data is loaded into the device, the pre-computed CRC is shifted into the CRC circuitry. ■ Simultaneously, the CRC value for the data frame shifted-in is calculated. If the pre-computed CRC and calculated CRC values do not match, nSTATUS is set low. ■ Every data frame has a 16-bit CRC. Therefore, there are many 16-bit CRC values for the whole configuration bit stream. ■ Every device has a different length of configuration data frame. This section focuses on the first type—the 32-bit CRC when the device is in user mode. Error Detection Registers There are two sets of 32-bit registers in the error detection circuitry that store the computed CRC signature and pre-calculated CRC value. A non-zero value on the signature register causes the CRC_ERROR pin to set high. Figure 9–1 shows the block diagram of the error detection block and the two related 32-bit registers: the signature register and the storage register. Figure 9–1. Error Detection Block Diagram Error Detection State Machine Control Signals Compute & Compare CRC 32 32-bit Storage Register 32 32-bit Signature Register 32 Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 9: SEU Mitigation in Cyclone IV Devices Error Detection Timing 9–5 Table 9–4 defines the registers shown in Figure 9–1. Table 9–4. Error Detection Registers Register Function 32-bit signature register This register contains the CRC signature. The signature register contains the result of the user mode calculated CRC value compared against the pre-calculated CRC value. If no errors are detected, the signature register is all zeros. A non-zero signature register indicates an error in the configuration CRAM contents. The CRC_ERROR signal is derived from the contents of this register. 32-bit storage register This register is loaded with the 32-bit pre-computed CRC signature at the end of the configuration stage. The signature is then loaded into the 32-bit CRC circuit (called the Compute and Compare CRC block, as shown in Figure 9–1) during user mode to calculate the CRC error. This register forms a 32-bit scan chain during execution of the CHANGE_EDREG JTAG instruction. The CHANGE_EDREG JTAG instruction can change the content of the storage register. Therefore, the functionality of the error detection CRC circuitry is checked in-system by executing the instruction to inject an error during the operation. The operation of the device is not halted when issuing the CHANGE_EDREG instruction. Error Detection Timing When the error detection CRC feature is enabled through the Quartus II software, the device automatically activates the CRC process upon entering user mode after configuration and initialization is complete. The CRC_ERROR pin is driven low until the error detection circuitry has detected a corrupted bit in the previous CRC calculation. After the pin goes high, it remains high during the next CRC calculation. This pin does not log the previous CRC calculation. If the new CRC calculation does not contain any corrupted bits, the CRC_ERROR pin is driven low. The error detection runs until the device is reset. The error detection circuitry runs off an internal configuration oscillator with a divisor that sets the maximum frequency. Table 9–5 lists the minimum and maximum error detection frequencies. Table 9–5. Minimum and Maximum Error Detection Frequencies Device Type Cyclone IV © November 2009 Altera Corporation Error Detection Frequency Maximum Error Detection Frequency Minimum Error Detection Frequency Valid Divisors (2n) 80 MHz/2n 80 MHz 312.5 kHz 0, 1, 2, 3, 4, 5, 6, 7, 8 Cyclone IV Device Handbook, Volume 1 9–6 Chapter 9: SEU Mitigation in Cyclone IV Devices Error Detection Timing You can set a lower clock frequency by specifying a division factor in the Quartus II software (for more information, refer to “Software Support”). The divisor is a power of two (2), where n is between 0 and 8. The divisor ranges from one through 256. Refer to Equation 9–1. Equation 9–1. 80 MHz Error detection frequency = -----------------n 2 CRC calculation time depends on the device and the error detection clock frequency. Table 9–6 lists the estimated time for each CRC calculation with minimum and maximum clock frequencies for Cyclone IV devices. Table 9–6. CRC Calculation Time Device Minimum Time (ms) (1) Maximum Time (s) (2) EP4CGX15 6 2.93 EP4CGX22 12 5.95 EP4CGX30 12 5.95 EP4CGX50 34 17.34 EP4CGX75 34 17.34 EP4CGX110 62 31.27 EP4CGX150 62 31.27 Notes to Table 9–6: (1) The minimum time corresponds to the maximum error detection clock frequency and may vary with different processes, voltages, and temperatures (PVT). (2) The maximum time corresponds to the minimum error detection clock frequency and may vary with different PVT. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 9: SEU Mitigation in Cyclone IV Devices Software Support 9–7 Software Support Enabling the CRC error detection feature in the Quartus II software generates the CRC_ERROR output to the optional dual purpose CRC_ERROR pin. To enable the error detection feature using CRC, perform the following steps: 1. Open the Quartus II software and load a project using Cyclone IV devices. 2. On the Assignments menu, click Settings. The Settings dialog box appears. 3. In the Category list, select Device. The Device page appears. 4. Click Device and Pin Options. The Device and Pin Options dialog box appears as shown in Figure 9–2. 5. In the Device and Pin Options dialog box (Figure 9–2), click the Error Detection CRC tab. 6. Turn on Enable error detection CRC. 7. In the Divide error check frequency by box, enter a valid divisor as documented in Table 9–5 on page 9–5. 1 The divisor value divides down the frequency of the configuration oscillator output clock. This output clock is used as the clock source for the error detection process. 8. Click OK. Figure 9–2. Enabling the Error Detection CRC Feature in the Quartus II Software © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 9–8 Chapter 9: SEU Mitigation in Cyclone IV Devices Software Support Accessing Error Detection Block Through User Logic The error detection circuit stores the computed 32-bit CRC signature in a 32-bit register. This signature is read out by user logic from the core. The cycloneiv_crcblock primitive is a WYSIWYG component used to establish the interface from the user logic to the error detection circuit. The cycloneiv_crcblock primitive atom contains the input and output ports that must be included in the atom. To access the logic array, the cycloneiv_crcblock WYSIWYG atom must be inserted into your design. Figure 9–3 shows the error detection block diagram in FPGA devices and shows the interface that the WYSIWYG atom enables in your design. Figure 9–3. Error Detection Block Diagram 80 MHz Internal Chip Oscillator Clock Divider (1 to 256 Factor) VCC CRC_ERROR (Shown in BIDIR Mode) Pre-Computed CRC (Saved in the Option Register) LDSRC CRC_ERROR SHIFTNLD CRC Computation CLK SRAM Bits REGOUT Error Detection Logic Logic Array 1 The user logic is affected by the soft error failure, so reading out the 32-bit CRC signature through the regout should not be relied upon to detect a soft error. You should rely on the CRC_ERROR output signal itself, because this CRC_ERROR output signal cannot be affected by a soft error. To enable the cycloneiv_crcblock WYSIWYG atom, you must name the atom for each Cyclone IV device accordingly. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 9: SEU Mitigation in Cyclone IV Devices Software Support 9–9 Example 9–1 shows an example of how to define the input and output ports of a WYSIWYG atom in a Cyclone IV device. Example 9–1. Error Detection Block Diagram cycloneiv_crcblock<crcblock_name> ( .clk(<clock source>), .shiftnld(<shiftnld source>), .ldsrc(<ldsrc source>), .crcerror(<crcerror out destination>), .regout(<output destination>), ); Table 9–7 lists the input and output ports that must be included in the atom. Table 9–7. CRC Block Input and Output Ports (Part 1 of 2) Port Input/Output Definition <crcblock_name> Input Unique identifier for the CRC block, and represents any identifier name that is legal for the given description language (for example, Verilog HDL, VHDL, and AHDL). This field is required. .clk(<clock source> Input This signal designates the clock input of this cell. All operations of this cell are with respect to the rising edge of the clock. Whether it is the loading of the data into the cell or data out of the cell, it always occurs on the rising edge. This port is required. .shiftnld (<shiftnld Input This signal is an input into the error detection block. If shiftnld=1, the data is shifted from the internal shift register to the regout at each rising edge of clk. If shiftnld=0, the shift register parallel loads either the pre-calculated CRC value or the update register contents depending on the ldsrc port input. To do this, the shiftnld needs to be driven low for at least two clock cycles. This port is required. Input This signal is an input into the error detection block. If ldsrc=0, the pre-computed CRC register is selected for loading into the 32-bit shift register at the rising edge of clk when shiftnld=0. If ldsrc=1, the signature register (result of the CRC calculation) is selected for loading into the shift register at the rising edge of clk when shiftnld=0. This port is ignored when shiftnld=1. This port is required. source>) .ldsrc (<ldsrc source>) © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 9–10 Chapter 9: SEU Mitigation in Cyclone IV Devices Recovering from CRC Errors Table 9–7. CRC Block Input and Output Ports (Part 2 of 2) Port Input/Output Definition Output This signal is the output of the cell that is synchronized to the internal oscillator of the device (80-MHz internal oscillator) and not to the clk port. It asserts high if the error block detects that a SRAM bit has flipped and the internal CRC computation has shown a difference with respect to the pre-computed value. This signal must be connected either to an output pin or a bidirectional pin. If it is connected to an output pin, you can only monitor the CRC_ERROR pin (the core cannot access this output). If the CRC_ERROR signal is used by core logic to read error detection logic, this signal must be connected to a BIDIR pin. The signal is fed to the core indirectly by feeding a BIDIR pin that has its output enable port connected to VCC (see Figure 9–3 on page 9–8). Output This signal is the output of the error detection shift register synchronized to the clk port, to be read by core logic. It shifts one bit at each cycle, so you should clock the clk signal 31 cycles to read out the 32 bits of the shift register. .crcerror (<crcerror indicator output>) .regout (<registered output>) Recovering from CRC Errors The system that the Altera FPGA resides in must control device reconfiguration. After detecting an error on the CRC_ERROR pin, strobing the nCONFIG low directs the system to perform the reconfiguration at a time when it is safe for the system to reconfigure the FPGA. When the data bit is rewritten with the correct value by reconfiguring the device, the device functions correctly. While soft errors are uncommon in Altera devices, certain high-reliability applications might require a design to account for these errors. Chapter Revision History Table 9–8 lists the revision history for this chapter. Table 9–8. Chapter Revision History Date Version November 2009 1.0 Cyclone IV Device Handbook, Volume 1 Changes Made Initial release. © November 2009 Altera Corporation 10. JTAG Boundary-Scan Testing for Cyclone IV Devices CYIV-51010-1.0 This chapter describes the boundary-scan test (BST) features that are supported in Cyclone® IV devices. The features are similar to Cyclone III devices, unless stated in this chapter. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. Cyclone IV devices support IEEE Std. 1149.1 and IEEE Std. 1149.6. The IEEE Std. 1149.6 is only supported on the high-speed serial interface (HSSI) transceivers in Cyclone IV devices. The purpose of IEEE Std. 1149.6 is to enable board-level connectivity checking between transmitters and receivers that are AC coupled (connected with a capacitor in series between the source and destination). This chapter includes the following sections: ■ “IEEE Std. 1149.6 Boundary-Scan Register” on page 10–2 ■ “BST Operation Control” on page 10–3 ■ “I/O Voltage Support in a JTAG Chain” on page 10–5 ■ “Boundary-Scan Description Language Support” on page 10–6 f For information about the JTAG instructions code with descriptions and IEEE Std.1149.1 BST guidelines, refer to the IEEE 1149.1 (JTAG) Boundary-Scan Testing for Cyclone III Devices chapter in volume 1 of the Cyclone III Device Handbook. f For information about the following topics, refer to AN 39: IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera Devices: © November 2009 ■ IEEE Std. 1149.1 BST architecture and circuitry ■ TAP controller state-machine ■ Instruction mode Altera Corporation Cyclone IV Device Handbook, Volume 1 10–2 Chapter 10: JTAG Boundary-Scan Testing for Cyclone IV Devices IEEE Std. 1149.6 Boundary-Scan Register IEEE Std. 1149.6 Boundary-Scan Register The boundary-scan cell (BSC) for HSSI transmitters (GXB_TX[p,n]) and receivers (GXB_RX[p,n]) in Cyclone IV devices are different from the BSCs for I/O pins. Figure 10–1 shows the Cyclone IV HSSI transmitter boundary-scan cell. Figure 10–1. Cyclone IV HSSI Transmitter BSC with IEEE Std. 1149.6 BST Circuitry BSCAN PMA SDOUT 0 AC JTAG Output Buffer BSTX1 0 OE D Q D Q 1 1 Pad Mission (DATAOUT) 0 D D Q Q Tx Output Buffer 0 1 BS0EB 1 nOE Pad OE Logic M0 RHZ 0 0 BSTX0 D D Q Q AC JTAG Output Buffer 1 1 MEM_INIT SDIN SHIFT CLK UPDATE HIGHZ AC_TEST OE AC_MODE MODE Capture Update Registers Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 10: JTAG Boundary-Scan Testing for Cyclone IV Devices BST Operation Control 10–3 Figure 10–2 shows the Cyclone IV HSSI receiver BSC. Figure 10–2. Cyclone IV HSSI Receiver BSC with IEEE Std. 1149.6 BST Circuitry BSCAN SDOUT PMA AC JTAG Test Receiver BSRX1 Hysteretic Memory 0 BSOUT1 D Q Pad Mission (DATAIN) Optional INTEST/RUNBIST not supported 1 0 Hysteretic Memory BSOUT0 Q Pad AC JTAG Test Receiver BSRX0 D Rx Input Buffer 1 HIGHZ SCIN SHIFT CLK UPDATE AC_TEST MEM_INIT MODE AC_MODE Capture Update Registers f For information about Cyclone IV user I/O boundary-scan cells, refer to the IEEE 1149.1 (JTAG) Boundary-Scan Testing for Cyclone III Devices chapter in volume 1 of the Cyclone III Device Handbook. BST Operation Control Table 10–1 shows the boundary-scan register length for Cyclone IV devices. Table 10–1. Cyclone IV Boundary-Scan Register Length © November 2009 Altera Corporation Device Boundary-Scan Register Length EP4CGX15 260 EP4CGX22 494 EP4CGX30 494 EP4CGX50 1006 EP4CGX75 1006 EP4CGX110 1495 EP4CGX150 1495 Cyclone IV Device Handbook, Volume 1 10–4 Chapter 10: JTAG Boundary-Scan Testing for Cyclone IV Devices BST Operation Control Table 10–2 shows the IDCODE information for Cyclone IV devices. Table 10–2. 32-Bit Cyclone IV Device IDCODE IDCODE (32 Bits) (1) Device Version (4 Bits) Part Number (16 Bits) Manufacturer Identity (11 Bits) LSB (1 Bit) (2) EP4CGX15 0000 0010 1000 0000 0001 000 0110 1110 1 EP4CGX22 0000 0010 1000 0001 0010 000 0110 1110 1 EP4CGX30 0000 0010 1000 0000 0010 000 0110 1110 1 EP4CGX50 0000 0010 1000 0010 0011 000 0110 1110 1 EP4CGX75 0000 0010 1000 0000 0011 000 0110 1110 1 EP4CGX110 0000 0010 1000 0001 0100 000 0110 1110 1 EP4CGX150 0000 0010 1000 0000 0100 000 0110 1110 1 Notes to Table 10–2: (1) The MSB is on the left. (2) The IDCODE LSB is always 1. IEEE Std.1149.6 mandates the addition of two new instructions: EXTEST_PULSE and EXTEST_TRAIN. These two instructions enable edge-detecting behavior on the signal path containing the AC pins. EXTEST_PULSE The instruction code for EXTEST_PULSE is 0010001111. The EXTEST_PULSE instruction generates three output transitions: ■ Driver drives data on the falling edge of TCK in UPDATE_IR/DR. ■ Driver drives inverted data on the falling edge of TCK after entering the RUN_TEST/IDLE state. ■ Driver drives data on the falling edge of TCK after leaving the RUN_TEST/IDLE state. EXTEST_TRAIN The instruction code for EXTEST_TRAIN is 0001001111. The EXTEST_TRAIN instruction behaves the same as the EXTEST_PULSE instruction with one exception. The output continues to toggle on the TCK falling edge as long as the TAP controller is in the RUN_TEST/IDLE state. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 10: JTAG Boundary-Scan Testing for Cyclone IV Devices I/O Voltage Support in a JTAG Chain 10–5 I/O Voltage Support in a JTAG Chain A Cyclone IV device operating in BST mode uses four required pins: TDI, TDO, TMS, and TCK. The TDO output pin and all JTAG input pins are powered by the VCCIO power supply of I/O Bank 9. A JTAG chain can contain several different devices. However, you must use caution if the chain contains devices that have different VCCIO levels. The output voltage level of the TDO pin must meet the specification of the TDI pin it drives. For example, a device with a 3.3-V TDO pin can drive a device with a 5.0-V TDI pin because 3.3 V meets the minimum TTL-level VIH for the 5.0-V TDI pin. 1 For multiple devices in a JTAG chain with 3.0-V/3.3-V I/O standard, you must connect a 25-Ω series resistor on a TDO pin driving a TDI pin. You can also interface the TDI and TDO lines of the devices that have different VCCIO levels by inserting a level shifter between the devices. If possible, the JTAG chain should have a device with a higher VCCIO level driving a device with an equal or lower VCCIO level. This way, a level shifter may be required only to shift the TDO level to a level acceptable to the JTAG tester. Figure 10–3 shows the JTAG chain of mixed voltages and how a level shifter is inserted in the chain. Figure 10–3. JTAG Chain of Mixed Voltages Must be 3.3-V tolerant TDI 3.3 V VCCIO 2.5 V VCCIO Tester TDO © November 2009 Altera Corporation Level Shifter 1.5 V VCCIO 1.8 V VCCIO Shift TDO to level accepted by tester if necessary Must be 1.8-V tolerant Must be 2.5-V tolerant Cyclone IV Device Handbook, Volume 1 10–6 Chapter 10: JTAG Boundary-Scan Testing for Cyclone IV Devices Boundary-Scan Description Language Support Boundary-Scan Description Language Support The boundary-scan description language (BSDL), a subset of VHDL, provides a syntax that allows you to describe the features of an IEEE Std. 1149.6 BST-capable device that can be tested. f To download BSDL files for IEEE Std. 1149.6-compliant Cyclone IV devices, visit the Altera® website at www.altera.com. f You can also generate BSDL files (pre-configuration and post-configuration) for IEEE std. 1149.6-compliant Cyclone IV devices with the Quartus® II software version 9.1 SP1 and later. For more information about the procedure to generate BSDL files using the Quartus II software, visit the Altera website at www.altera.com. Chapter Revision History Table 10–3 lists the revision history for this chapter. Table 10–3. Chapter Revision History Date Version November 2009 1.0 Cyclone IV Device Handbook, Volume 1 Changes Made Initial release. © November 2009 Altera Corporation 11. Power Requirements for Cyclone IV Devices CYIV-51011-1.0 This chapter describes the static power and dynamic power that makes up the total power requirements of an Altera ® Cyclone® IV FPGA. Static power is the power consumed by the FPGA when it is configured while no clocks are operational. Dynamic power consist of the switching power when the device is configured and running. The Quartus® II software optimizes all designs with Cyclone IV power technology to ensure performance is met at the lowest power consumption. This automatic process allows you to concentrate on the functionality of your design instead of the power consumption of your design. This chapter includes the following sections: f ■ “External Power Supply Requirements” on page 11–1 ■ “Hot-Socketing Specifications” on page 11–2 ■ “Hot-socketing Feature Implementation” on page 11–3 ■ “Power-On Reset Circuitry” on page 11–3 For more information about using the PowerPlay Power Analyzer in the Quartus II software, refer to the Power Estimation and Power Analysis section in volume 3 of the Quartus II Handbook. External Power Supply Requirements This section describes the different external power supplies needed to power Cyclone IV devices. Table 11–1 and Table 11–2 list the descriptions of external power supply pins for Cyclone IV GX and Cyclone IV E devices respectively. f For each Altera recommended power supply’s operating conditions, refer to the Cyclone IV Device Data Sheet chapter in volume 3. f For power supply pin connection guidelines and power regulator sharing, refer to the Cyclone IV Device Family Pin Connection Guidelines. Table 11–1. Cyclone IV GX Power Supply Descriptions (Part 1 of 2) Power Supply Pin © November 2009 Nominal Voltage Level (V) Description VCCINT 1.2 Core voltage, PCI Express (PCIe) Hard IP block, and transceiver physical coding sublayer (PCS) power supply VCCA (1) 2.5 PLL analog power supply VCCD_PLL 1.2 PLL digital power supply VCCIO (2) 1.2, 1.5, 1.8, 2.5, 3.0, 3.3 I/O banks power supply Altera Corporation Cyclone IV Device Handbook, Volume 1 11–2 Chapter 11: Power Requirements for Cyclone IV Devices Hot-Socketing Specifications Table 11–1. Cyclone IV GX Power Supply Descriptions (Part 2 of 2) Power Supply Pin VCC_CLKIN (3), (4) Nominal Voltage Level (V) 1.2, 1.5, 1.8, 2.5, 3.0, 3.3 Description Differential clock input pins power supply VCCH_GXB 2.5 Transceiver output (Tx) buffer power supply VCCA_GXB 2.5 Transceiver physical medium attachment (PMA) and auxiliary power supply VCCL_GXB 1.2 Transceiver PMA and auxiliary power supply 0 GND Ground Notes to Table 11–1: (1) VCCA must be powered up even if the phase-locked loop (PLL) is not used. (2) I/O Banks 3, 8, and 9 contain configuration pins. The VCCIO level of I/O Banks 3 and 9 can only be powered up to 1.5 V, 1.8 V, 2.5 V, 3.0 V, and 3.3 V. For Fast Passive Parallel (FPP) configuration mode, the VCCIO level of I/O Bank 8 must be powered up to 1.5 V, 1.8 V, 2.5 V, 3.0 V, and 3.3 V. (3) EP4CGX15, EP4CGX22, and EP4CGX30 devices have two VCC_CLKIN dedicated clock input I/O located at Banks 3A and 8A. EP4CGX50, EP4CGX75, EP4CGX110, and EP4CGX150 devices have four VCC_CLKIN dedicated clock input I/O bank located at Banks 3A, 3B, 8A, and 8B. (4) VCC_CLKIN must be set to 2.5 V if the CLKIN is used as high-speed serial interface (HSSI) refclk. VCC_CLKIN located at I/O Banks 3B and 8B only support a nominal voltage level of 2.5 V for LVDS input function because they are dedicated for HSSI refclk. Table 11–2. Cyclone IV E Power Supply Descriptions Power Supply Pin Nominal Voltage Level (V) Description VCCINT 1.0 Core voltage power supply VCCA (1) 2.5 PLL analog power supply VCCD_PLL 1.0 PLL digital power supply 1.2, 1.5, 1.8, 2.5, 3.0, 3.3 I/O banks power supply VCCIO GND 0 Ground Note to Table 11–2: (1) VCCA must be powered up even if the PLL is not used. Hot-Socketing Specifications Cyclone IV devices are hot-socketing compliant without the need for any external components or special design requirements. Hot-socketing support in Cyclone IV devices have the following advantages: ■ You can drive the device before power-up without damaging the device. ■ I/O pins remain tri-stated during power-up. The device does not drive out before or during power-up. Therefore, it does not affect other buses in operation. Cyclone IV Device Handbook, Volume 1 © November 2009 Altera Corporation Chapter 11: Power Requirements for Cyclone IV Devices Hot-socketing Feature Implementation 11–3 Devices Driven Before Power-Up You can drive signals into regular Cyclone IV E I/O pins or regular and transceiver Cyclone IV GX I/O pins before or during power-up or power-down without damaging the device. Cyclone IV devices support any power-up or power-down sequence to simplify system level design. I/O Pins Remain Tri-stated During Power-Up The output buffers of Cyclone IV devices are turned off during system power up or power down. Cyclone IV devices do not drive out until the device is configured and working in recommended operating conditions. The I/O pins are tri-stated until the device enters user mode. A possible concern for semiconductor devices in general regarding hot-socketing is the potential for latch up. Latch up can occur when electrical subsystems are hot-socketed into an active system. During hot-socketing, the signal pins may be connected and driven by the active system before the power supply can provide current to the VCC of the device and ground planes. This condition can lead to latch up and cause a low-impedance path from VCC to ground in the device. As a result, the device extends a large amount of current, possibly causing electrical damage. The design of the I/O buffers and hot-socketing circuitry ensures that Cyclone IV devices are immune to latch up during hot-socketing. f For more information about the hot-socketing specification, refer to the Cyclone IV Device Data Sheet chapter in volume 3 and the Hot-Socketing and Power-Sequencing Feature and Testing for Altera Devices white paper. Hot-socketing Feature Implementation The hot-socketing circuit does not include CONF_DONE, nCEO, and nSTATUS pins to ensure that they are able to operate during configuration. The expected behavior for these pins is to drive out during power up and power down sequences. 1 Altera uses GND as reference for hot-socketing operation and I/O buffer designs. To ensure proper operation, Altera recommends connecting the GND between boards before connecting the power supplies. This prevents the GND on your board from being pulled up inadvertently by a path to power through other components on your board. A pulled up GND can otherwise cause an out-of-specification I/O voltage or current condition with the Altera device. Power-On Reset Circuitry Cyclone IV devices contain power-on reset (POR) circuitry to keep the device in a reset state until the power supply voltage levels have stabilized during power up. During POR, all user I/O pins are tri-stated until the power supplies reach the recommended operating levels. In addition, the POR circuitry also ensures the VCCIO level of I/O banks that contain configuration pins reach an acceptable level before configuration is triggered. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 1 11–4 Chapter 11: Power Requirements for Cyclone IV Devices Chapter Revision History The POR circuit of the Cyclone IV device monitors the VCCINT, VCCA, and VCCIO that contain configuration pins during power-on. You can power up or power down the VCCINT, VCCA, and VCCIO pins in any sequence. The VCCINT, VCCA, and VCCIO must have a monotonic rise to their steady state levels. All V CCA pins must be powered to 2.5V (even when PLLs are not used), and must be powered up and powered down at the same time. After the Cyclone IV device enters the user mode, the POR circuit continues to monitor the VCCINT and VCCA pins so that a brown-out condition during user mode is detected. If the VCCINT or V CCA voltage sags below the POR trip point during user mode, the POR circuit resets the device. If the VCCIO voltage sags during user mode, the POR circuit does not reset the device. In some applications, it is necessary for a device to wake up very quickly to begin operation. Cyclone IV devices offer the Fast-On feature to support fast wake-up time applications. The MSEL pin settings determine the POR time (t POR ) of the device. f For more information about the MSEL pin settings, refer to the Configuration, Design Security, and Remote System Upgrades in Cyclone IV Devices chapter in volume 1. f For more information about the POR specifications, refer to the Cyclone IV Device Data Sheet chapter in volume 3. Chapter Revision History Table 11–3 lists the revision history for this chapter. Table 11–3. Chapter Revision History Date Version November 2009 1.0 Cyclone IV Device Handbook, Volume 1 Changes Made Initial release. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 101 Innovation Drive San Jose, CA 95134 www.altera.com CYIV-5V2-1.0 Copyright © 2009 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. RSDS and PPDS are registered trademarks of National Semiconductor. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Contents Chapter Revision Dates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Additional Information About this Handbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v How to Contact Altera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v Typographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v Section 1. Transceivers Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Chapter 1. Cyclone IV Transceivers Architecture Architectural Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Top-Level Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Receive (Rx) Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Transmit (Tx) Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Clock and MPLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Power-Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11 PHY Interface for the PCI Express Architecture (PIPE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 Tx Datapath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 Tx Phase Compensation FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13 Byte Serializer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 8B10B Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 Serializer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-16 Tx Output Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17 PCI Express Receiver Detect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 Rx Datapath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 Rx Input Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 Clock Data Recovery (CDR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 Deserializer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21 Word Aligner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21 Rate Match FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 Rate Match FIFO in PCI Express (PIPE) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 Rate Match FIFO in GIGE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 8B10B Decoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 Byte Deserializer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 Rx Phase Compensation FIFO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25 Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-31 Reverse Parallel Loopback Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 Serial Loopback Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 Reverse Serial Loopback Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 Reset Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 PCI Express (PIPE) Mode Reset Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36 Initialization/Compliance Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36 Normal Operation Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37 GIGE Reset Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-37 Power Down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-38 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 ii Contents Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLL/Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ports/Cal Blk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rx Analog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx Analog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protocol Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cyclone IV Device Handbook, Volume 2 1-39 1-40 1-41 1-42 1-43 1-43 1-43 1-44 © November 2009 Altera Corporation Chapter Revision Dates The chapters in this book, Cyclone IV Device Handbook, Volume 2, were revised on the following dates. Where chapters or groups of chapters are available separately, part numbers are listed. Chapter 1 © November 2009 Cyclone IV Transceivers Architecture Revised: November 2009 Part Number: CYIV-52001-1.0 Altera Corporation Cyclone IV Device Handbook, Volume 2 iv Cyclone IV Device Handbook, Volume 2 Chapter Revision Dates © November 2009 Altera Corporation Additional Information About this Handbook This handbook provides comprehensive information about the Altera® Cyclone® IV family of devices. How to Contact Altera For the most up-to-date information about Altera products, see the following table. Contact (Note 1) Contact Method Address Technical support Website www.altera.com/support Technical training Website www.altera.com/training Email custrain@altera.com Non-technical support (General) Email nacomp@altera.com (Software Licensing) Email authorization@altera.com Note: (1) You can also contact your local Altera sales office or sales representative. Typographic Conventions The following table shows the typographic conventions that this document uses. Visual Cue Meaning Bold Type with Initial Capital Letters Indicates command names, dialog box titles, dialog box options, and other GUI labels. For example, Save As dialog box. For GUI elements, capitalization matches the GUI. bold type Indicates directory names, project names, disk drive names, file names, file name extensions, dialog box options, software utility names, and other GUI labels. For example, \qdesigns directory, d: drive, and chiptrip.gdf. Italic Type with Initial Capital Letters Indicates document titles. For example, AN 519: Stratix IV Design Guidelines. Italic type Indicates variables. For example, n + 1. Variable names are enclosed in angle brackets (< >). For example, <file name> and <project name>.pof. Initial Capital Letters Indicates keyboard keys and menu names. For example, Delete key and the Options menu. “Subheading Title” Quotation marks indicate references to sections within a document and titles of Quartus II Help topics. For example, “Typographic Conventions.” © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 Info–vi Additional Information Visual Cue Courier type Meaning Indicates signal, port, register, bit, block, and primitive names. For example, data1, tdi, and input. Active-low signals are denoted by suffix n. For example, resetn. Indicates command line commands and anything that must be typed exactly as it appears. For example, c:\qdesigns\tutorial\chiptrip.gdf. Also indicates sections of an actual file, such as a Report File, references to parts of files (for example, the AHDL keyword SUBDESIGN), and logic function names (for example, TRI). 1., 2., 3., and a., b., c., and so on. Numbered steps indicate a list of items when the sequence of the items is important, such as the steps listed in a procedure. ■ ■ Bullets indicate a list of items when the sequence of the items is not important. 1 The hand points to information that requires special attention. c A caution calls attention to a condition or possible situation that can damage or destroy the product or your work. w A warning calls attention to a condition or possible situation that can cause you injury. r The angled arrow instructs you to press Enter. f The feet direct you to more information about a particular topic. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Section 1. Transceivers This section provides a complete overview of all features relating to the Cyclone® IV device transceivers. This section includes the following chapters: ■ Chapter 1, Cyclone IV Transceivers Architecture Revision History Refer to the chapter for its own specific revision history. For information about when the chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–2 Cyclone IV Device Handbook, Volume 2 Chapter: © November 2009 Altera Corporation 1. Cyclone IV Transceivers Architecture CYIV-52001-1.0 Cyclone® IV GX devices include up to eight full-duplex transceivers at serial data rates between 600 Mbps and 3.125 Gbps in a low-cost FPGA. Cyclone IV GX transceivers are designed to support the serial protocols listed in Table 1–1. Table 1–1. Protocol Support Protocol Data Rate (Gbps) PCI Express Gen1 (×1, ×2 [(1), (2)], and ×4) 2.5 Gigabit Ethernet 1.25 Basic (1) 0.6–3.125 Common Public Radio Interface (CPRI) (1) up to 3.072 XAUI (1) 3.125 Triple rate Serial Digital Interface (SDI) (1) up to 2.97 Serial RapidIO (SRIO) (1) up to 3.125 V-by-One (1) 3.0 DisplayPort (1) 2.7 SATA (1) up to 3.0 Notes to Table 1–1: (1) These protocols will be supported in a future version of the Quartus II software. (2) Cyclone IV GX devices support PCI Express Gen1 ×2, while allowing the remaining two channels within the same transceiver block for other protocol use. Only Channel 0 and Channel 1 support PCI Express Gen1 ×2 implementation. In addition, the devices include a hard IP implementation of a PCI Express MegaCore function. This implementation supports Gen1 ×1, ×2, and ×4 operations configured in root port or endpoint mode, making the Cyclone IV GX device an excellent platform for low-cost PCI Express (PIPE) designs. Cyclone IV GX transceivers are structured into full-duplex (transmitter and receiver) channel groups called transceiver blocks. The total number of transceiver channels and the location of transceiver blocks varies from device to device. Each transceiver block includes two multi-purpose phase locked loops (MPLL) that provide clocks to the transceiver channels. Hard IP for PCI Express is available only for transceiver block GXBL0. Figure 1–1 and Figure 1–2 show the layout of transceiver resources in Cyclone IV GX devices. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–2 Chapter 1: Cyclone IV Transceivers Architecture Figure 1–1. Cyclone IV GX Devices with One Transceiver Block Transceiver Block GXBL0 MPLL Channel 3 (1) Channel 2 (1) Channel 1 hard IP for PCIe EP4CGX15 EP4CGX22 EP4CGX30 EP4CGX50 (2) EP4CGX75 (2) EP4CGX110 (2) EP4CGX150 (2) Channel 0 MPLL Notes to Figure 1–1: (1) Channel 2 and Channel 3 are not available in the EP4CGX15 and F169 package type in EP4CGX22 and EP4CGX30. (2) Applicable for the F484 package type only. Figure 1–2. Cyclone IV GX Devices with Two Transceiver Blocks Transceiver Block GXBL1 EP4CGX50 EP4CGX75 EP4CGX110 EP4CGX150 MPLL Channel 3 Channel 2 Channel 1 Channel 0 MPLL Transceiver Block GXBL0 MPLL Channel 3 Channel 2 Channel 1 hard IP for PCIe Channel 0 MPLL You can instantiate and configure Cyclone IV GX transceivers with the ALTGX MegaWizard™ Plug-In Manager in the Quartus® II software. The ALTGX megafunction port lists and parameter settings are detailed in “Top-Level Signals” on page 1–4 and “Parameter Settings” on page 1–39. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Architectural Overview 1–3 Architectural Overview Figure 1–3 shows the primary modules in a Cyclone IV GX transceiver channel. Figure 1–3. Primary Modules of a Cyclone IV GX Transceiver Channel FPGA to Fabric Interface PCS to PMA Interface Transmitter Channel PCS FPGA Fabric Tx Output Buffer Tx Phase Comp FIFO Byte Serializer PIPE Interface PCI Express hard IP Transmitter Channel PMA 8B10B Encoder Serializer Receiver Channel PCS Rx Phase Comp FIFO Byte Deserializer 8B10B Decoder Receiver Channel PMA Rate Match FIFO Word Aligner Deserializer Rx Input Buffer CDR Each Cyclone IV GX transceiver channel contains a transmitter (Tx) and a receiver (Rx) datapath. Each Tx and Rx datapath is further structured into physical media attachment (PMA) and physical coding sublayer (PCS). Outbound parallel data from the FPGA fabric flows through the Tx PCS and Tx PMA, and transmitted as serial data. Received inbound serial data flows through the Rx PMA and Rx PCS into the FPGA fabric. 1 When configured in PCI Express (PIPE) functional mode, the transceiver interfaces through the PIPE interface to either FPGA fabric (to implement the PHY-MAC layer, data link layer, and transaction layer using soft IP) or the hard IP for PCI Express. The PIPE interface is compliant with Version 2.00 of the PHY Interface for the PCI Express Architecture (PIPE) specification. The following briefly describes the PCS and PMA modules: ■ PCS—Includes hard logic implementation of digital functionality within the transceiver that is compliant with supported protocols. ■ PMA—Includes analog circuitry for I/O buffers, clock data recovery (CDR), serializer/deserializer (SERDES), and programmable pre-emphasis and equalization to optimize serial data channel performance. Table 1–2 lists the widths and supported frequency for FPGA fabric-transceiver interfaces and widths for PMA-PCS interfaces. Table 1–2. FPGA Fabric-Transceiver Interface Width and Frequency, and PCS-PMA Interface Width (Part 1 of 2) Interfaces FPGA fabric-transceiver (PCS) interface widths FPGA fabric-transceiver (PCS) interface frequencies © November 2009 Altera Corporation Values 8/10 bit, 16/20 bit 125 MHz, 156.25 MHz (1) Cyclone IV Device Handbook, Volume 2 1–4 Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals Table 1–2. FPGA Fabric-Transceiver Interface Width and Frequency, and PCS-PMA Interface Width (Part 2 of 2) Interfaces PCS-PMA interface widths Values 8/10 bit Note to Table 1–2: (1) For EP4CGX50, EP4CGX75, EP4CGX110 and EP4CGX150 devices only. The PCI Express hard IP block includes the hard IP implementation PCI Express MegaCore function that contains the transaction, data link, and physical layers. The module supports 1, 2, or 4 lanes with a maximum payload of 256 bytes at Gen1 frequency. The application interface is 64 bits with a data width of 16 bits per channel running at up to 125 MHz. As a hard macro and a verified block, it uses very few FPGA resources, while significantly reducing design risk and the time required to achieve timing closure. It is compliant with the PCI Express Base Specification 1.1. You do not have to pay a licensing fee to use this module. f For more information about the PCI Express hard IP block, refer to the PCI Express Compiler User Guide. Top-Level Signals The ALTGX megafunction requires a relatively small number of signals. There are also a large number of optional signals that facilitate debugging by providing information about the state of the transceiver. Figure 1–4 shows the top-level ports of the ALTGX transceiver when configured in PCI Express (PIPE) functional modes. Within each signal group, the required signals are listed first, with the optional signals following. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals 1–5 Figure 1–4. ALTGX Ports for the PCI Express (PIPE) Functional Modes PCI Express (PIPE) ×N (1) Required Receive (Rx) Optional Clock & PLL Required Optional Required Power Down Optional rx_datain[N-1:0] rx_dataout[16N-1:0] rx_digitalreset rx_analogreset tx_dataout[N-1:0] tx_datain[16N-1:0] tx_ctrlenable[2N-1:0] tx_clkout (when N=1 only) tx_digitalreset tx_coreclk[N-1:0] tx_phase_comp_fifo_error[N-1:0] tx_detectrxloop[N-1:0] tx_forcedisp[N-1:0] tx_dispval[N-1:0] tx_invpolarity[N-1:0] rx_coreclk[N-1:0] rx_locktorefclk[N-1:0] rx_locktodata[N-1:0] rx_ctrldetect[2N-1:0] rx_errdetect[2N-1:0] rx_disperr[2N-1:0] rx_freqlocked[N-1:0] rx_signaldetect[N-1:0] pipeelecidle[N-1:0] rx_phase_comp_fifo_error[N-1:0] pipestatus[3N-1:0] rx_syncstatus[2N-1:0] pipe8b10binvpolarity[N-1:0] rx_patterndetect[2N-1:0] pipedatavalid[N-1:0] rx_rlv[N-1:0] pipephydonestatus[N-1:0] pll_inclk tx_forceelecidle[N-1:0] cal_blk_clk rx_elecidleinfersel[3N-1:0] coreclkout (when N>1 only) fixedclk pll_locked Required Transmit (Tx) Optional Required Optional PIPE Interface (PCIe) (2) pll_powerdown gxb_powerdown cal_blk_powerdown powerdn [2N-1:0] Notes to Figure 1–4: (1) N = 1 (non-bonded) or 4 (bonded). (2) The signals in blue are for simulation of the hard IP PCI Express MegaCore function or for use with soft IP implementation. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–6 Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals Figure 1–5 shows the top-level ports of the ALTGX transceiver when configured in GIGE functional mode. Figure 1–5. ALTGX Ports for the GIGE Functional Mode GIGE rx_datain rx_dataout[7:0] rx_digitalreset rx_analogreset Required rx_coreclk rx_locktorefclk rx_locktodata rx_ctrldetect rx_errdetect rx_disperr rx_freqlocked rx_phase_comp_fifo_error rx_syncstatus rx_patterndetect rx_runningdisp rx_rmfifofull rx_rmfifoempty rx_rmfifodatainserted rx_rmfifodatadeleted rx_rlv rx_invpolarity Receive (Rx) Optional Clock & PLL Power Down tx_dataout tx_datain[7:0] tx_ctrlenable tx_clkout tx_digitalreset tx_coreclk tx_phase_comp_fifo_error tx_disval tx_invpolarity Required Transmit (Tx) Optional pll_inclk cal_blk_clk pll_locked Required Optional pll_powerdown gxb_powerdown cal_blk_powerdown Required Optional Table 1–3 lists the ALTGX transceiver interfaces with links to the subsequent sections that describe each interface. Table 1–3. Signal Groups in the ALTGX Megafunction Signal Group PCI Express GIGE Receive (Rx) Port v v “Receive (Rx) Port” on page 1–7 Transmit (Tx) Port v v “Transmit (Tx) Port” on page 1–9 Clock and MPLL v v “Clock and MPLL” on page 1–10 Power Down v v “Power-Down” on page 1–11 PIPE v — “PHY Interface for the PCI Express Architecture (PIPE)” on page 1–12 Cyclone IV Device Handbook, Volume 2 Description © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals 1–7 Receive (Rx) Port Table 1–4 describes the signals that comprise the Rx port. Table 1–4. Rx Signals (Part 1 of 3) Signal I/O Required Input Yes Receiver serial data input port. Output Yes Parallel data output from the receiver to the FPGA fabric. The bus width <n> is the channel width (x) multiplied by the number of channels (N) per instance: <n> = xN-1 rx_digitalreset Input Yes Receiver PCS reset. When asserted, the receiver PCS blocks are reset. The minimum pulse width for the reset signal is two parallel clock cycles. rx_analogreset Input Yes Receiver PMA reset. When asserted, analog circuitry in the receiver PMA block is reset. The minimum pulse width is two parallel clock cycles. rx_clkout Output No This is the parallel clock that clocks parallel data out of the Rx deserializer. rx_coreclk Input No Optional read clock port for the receiver phase compensation FIFO. rx_locktorefclk Input No Receiver CDR lock-to-reference (LTR) mode control signal. The rx_locktorefclk and rx_locktodata signals control whether the receiver CDR is in LTR or lock-to-data (LTD) mode, as follows: rx_datain rx_dataout[<n>:0] Description [rx_locktodata:rx_locktorefclk] ■ 2'b00—receiver CDR is in automatic mode ■ 2b'01—receiver CDR is in LTR clock mode ■ 2b'1x—receiver CDR is in LTD mode This signal is asynchronous. rx_locktodata Input No Receiver CDR LTD mode control signal. When asserted, the receiver CDR is forced to LTD mode. When de-asserted, the receiver CDR lock mode depends on the rx_locktorefclk signal level. rx_ctrldetect Output No Receiver control code indicator. When asserted, indicates that the associated received code group is a control (/Kx.y/) code group. A low level indicates that the associated received code group is a data (/Dx.y/) code group. rx_errdetect Output No 8B10B code group violation or disparity error indicator. When asserted, indicates that a code group violation or disparity error was detected on the associated received code group. Use with the rx_disperr signal to differentiate between a code group violation or a disparity error as follows: [rx_errdetect:rx_disperr] rx_disperr Output © November 2009 Altera Corporation No ■ 2'b00—no error ■ 2'b10—code group violation ■ 2'b11—disparity error or both 8B10B disparity error indicator. When asserted, indicates that a disparity error was detected on the associated received code group. Cyclone IV Device Handbook, Volume 2 1–8 Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals Table 1–4. Rx Signals (Part 2 of 3) Signal rx_freqlocked I/O Required Description Output No An optional port that indicates whether the parts per million (PPM) difference is within the allowed limit. When high, the PPM difference is within the limit to the provided reference clock. This is an asynchronous signal. rx_signaldetect Output No Signal threshold detect indicator. Available only in PCI Express (PIPE) mode. When asserted, this indicates that the signal present at the receiver input buffer is above the programmed signal detection threshold value. If the electrical idle inference block is disabled in PCI Express (PIPE) mode, the rx_signaldetect signal is inverted and driven on the pipeelecidle port. This is an asynchronous signal. rx_phase_comp_ fifo_error Output No Receiver phase compensation FIFO full or empty indicator. When asserted, it indicates that the receiver phase compensation FIFO is either full or empty. rx_syncstatus Output No Indicates presence or absence of synchronization. rx_patterndetect Output No Indicates when the word alignment logic detects the alignment pattern in the current word boundary. rx_rlv Output No Run-length violation indicator. A high pulse indicates that the number of consecutive 1s or 0s in the received data stream exceeds the programmed run length violation threshold. This signal is asynchronous. It is driven for a minimum of two parallel clock cycles in configurations without a byte serializer and a minimum of three parallel clock cycles in configurations with a byte serializer. rx_invpolarity Input No Generic receiver polarity inversion control. Useful feature for correcting situations where the positive and negative signals of the differential serial link are accidentally swapped during board layout. When asserted, the input data word to the word aligner is inverted. This signal is not available for PCI Express (PIPE) mode. Asynchronous signal. rx_runningdisp Output No 8B10B running disparity indicator. When asserted, data on the rx_dataout port was received with a negative running disparity. A low level indicates that data on the rx_dataout port was received with a positive running disparity. rx_rmfifofull Output No Rate match FIFO full status indicator. When asserted, the rate match FIFO is full. Driven for a minimum of two serial clock cycles in configurations without a byte serializer and a minimum of three recovered clock cycles in configurations with a byte serializer. Not available for PCI Express (PIPE) mode. rx_rmfifoempty Output No Rate match FIFO empty status indicator. When asserted, the rate match FIFO is empty. Driven for a minimum of two serial clock cycles in configurations without a byte serializer and a minimum of three recovered clock cycles in configurations with a byte serializer. Not available for PCI Express (PIPE) mode. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals 1–9 Table 1–4. Rx Signals (Part 3 of 3) Signal I/O Required Description rx_rmfifodata inserted Output No Rate match FIFO insertion status indicator. When asserted, the rate match pattern byte is inserted to compensate for the PPM difference in the reference clock frequencies between the upstream transmitter and the local receiver. rx_rmfifodata deleted Output No Rate match FIFO deletion status indicator. When asserted, the rate match pattern byte is deleted to compensate for the PPM difference in the reference clock frequencies between the upstream transmitter and the local receiver. Transmit (Tx) Port Table 1–5 describes the signals that comprise the Tx port. Table 1–5. Tx Signals (Part 1 of 2) Signal I/O Required Output Yes Transmitter serial data output signal. tx_datain[<n>:0] Input Yes Parallel data input from the FPGA fabric to the transmitter. The bus width <n> is the channel width (x) multiplied by the number of channels (N) per instance: <n> = xN-1 tx_ctrlenable Input Yes 8B10B encoder /Kx.y/ or /Dx.y/ control. When asserted, the 8B10B encoder encodes the data on the tx_datain port as a /Kx.y/ control code group. When de-asserted, it encodes the data on the tx_datain port as a /Dx.y/ data code group. Output Yes FPGA fabric-transceiver interface clock. Each channel has a tx_clkout signal. This clock signal clocks parallel data tx_datain from the FPGA fabric into the transmitter. tx_digitalreset Input Yes Transmitter PCS reset. When asserted, the transmitter PCS blocks is reset. The minimum pulse width is two parallel clock cycles. tx_coreclk input No Optional write clock port for the transmitter phase compensation FIFO. tx_phase_comp_ fifo_error Output No Transmitter phase compensation FIFO full or empty indicator. When asserted, this indicates that the transmitter phase compensation FIFO is either full or empty. tx_detectrxloop Input No Receiver detect or PCI Express (PIPE) loopback control. The functionality is equivalent to the TxDetectRx/Loopback signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. tx_dataout tx_clkout Description When asserted in the P1 power state with the tx_forceelecidle signal asserted, the transmitter buffer begins the receiver detection operation to determine if there is a valid receiver downstream. This signal must be de-asserted when the pipephydonestatus signal indicates receiver detect completion. When asserted in the P0 power state with the tx_forceelecidle signal de-asserted, the transceiver datapath is dynamically configured to support reverse parallel loopback mode. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–10 Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals Table 1–5. Tx Signals (Part 2 of 2) Signal I/O Required Description tx_forcedisp Input No Forces the 8B10B encoder to encode with negative running disparity. Functionally equivalent to the TxCompliance signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. This must only be asserted when transmitting the first byte of the PCI Express (PIPE)-compliance pattern to force the 8B10B encoder with a negative running disparity. tx_dispval Input No 8B10B encoder forces disparity value. Determines whether the 8B10B encoder will code the incoming word using positive or negative disparity. tx_invpolarity Input No Transmitter polarity inversion control. This feature is useful for correcting situations where the positive and negative signals of the differential serial link are accidentally swapped during board layout. When asserted, the polarity of input data to the serializer is inverted. Asynchronous signal. Clock and MPLL Table 1–6 describes the MPLL and clock signals. Table 1–6. Clock and MPLL Signals Signal I/O Required pll_inclk Input Yes Input reference clock for the MPLL. cal_blk_clk Input Yes Clock for the transceiver calibration block. Output Yes (1) The clock output signal from the PCS for bonded configurations. Input No 125-MHz clock for receiver detect in PCI Express (PIPE) mode. Output No MPLL lock indicator. When asserted, indicates that the MPLL is locked to the input reference clock. coreclkout fixedclk pll_locked Description This signal is asynchronous. Note to Table 1–6: (1) coreclkout replaces tx_clkout in bonded configurations. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals 1–11 Power-Down Table 1–7 describes the signals you can use to power down various parts of the transceiver. Three of the four power-down signals are optional. Table 1–7. Power-Down Signals Signal pll_powerdown I/O Required Input Yes Description MPLL power down. When asserted, the MPLL is powered down. When deasserted, the MPLL is active and locks to the input reference clock. Asserting the pll_powerdown signal does not power down the refclk buffers. This signal is asynchronous. The minimum pulse width is 1 μs (pending characterization). gxb_powerdown Input No Transceiver block power down. When asserted, all digital and analog circuitry in the PCS, HSSI, CDR, MPLL, and PCI Express modules is powered down. Asserting the gxb_powerdown signal does not power down the refclk buffers. This signal is asynchronous. The minimum pulse width is 1 μs (pending characterization). cal_blk_powerdown Input No Calibration block power down control. powerdn[1:0] Input No PCI Express (PIPE) power state control. Functionally equivalent to the PowerDown[1:0] signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. The width of this signal is 2 bits and is encoded as follows: © November 2009 Altera Corporation ■ 2'b00—P0–Normal operation ■ 2'b01—P0s–Low recovery time latency, low power state ■ 2'b10—P1–Longer recovery time latency, lower power state ■ 2'b11—P2–Lowest power state Cyclone IV Device Handbook, Volume 2 1–12 Chapter 1: Cyclone IV Transceivers Architecture Top-Level Signals PHY Interface for the PCI Express Architecture (PIPE) Table 1–8 describes the signals that provide information about the status of the PCI Express (PIPE) interface. Table 1–8. (PIPE) Interface Signals Signal pipeelecidle I/O Required Description Output Yes Electrical idle detected or inferred at the receiver indicator. Functionally equivalent to the RxElecIdle signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. If the electrical idle inference block is enabled, it drives this signal high when it infers an electrical idle condition. If the electrical idle inference block is disabled, the rx_signaldetect signal is inverted and driven on this port. This signal is asynchronous. pipestatus[2:0] Input No PCI Express (PIPE) receiver status port. Functionally equivalent to the RxStatus[2:0] signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. The encoding of receiver status on the pipestatus port is as follows: ■ 3'b000—Received data OK ■ 3'b001—one SKP symbol added ■ 3'b010—one SKP symbol removed ■ 3'b011—Receiver detected ■ 3'b100—8B10B decoder error ■ 3'b101—Elastic buffer overflow ■ 3'b110—Elastic buffer underflow ■ 3'b111— Received disparity error Output No Valid data and control on the rx_dataout and rx_ctrldetect ports indicator. Functionally equivalent to the RxValid signal defined in the PHY Interface for PCI Express Architecture. Version 2.0. Input No Instructs the PHY layer to invert the polarity in the 8B10B receiver decoding block. pipephydonestatus Output No PHY function completion indicator. Functionally equivalent to the PhyStatus signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. Asserted for one clock cycle to communicate completion of several PHY functions, such as power state transition and receiver detection. tx_forceelecidle Input No Forces the transmitter buffer to PCI Express (PIPE) electrical idle signal levels. Functionally equivalent to the TxElecIdle signal defined in the PHY Interface for PCI Express Architecture, Version 2.0. rx_elecidleinfer sel[2:0] Input No Controls the electrical idle inference mechanism used for the PCI Express protocol. pipedatavalid pipe8b10binvpolarity Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Tx Datapath 1–13 Tx Datapath Figure 1–6 illustrates the Tx channel datapath. Figure 1–6. Modules in the Tx Channel Datapath Tx Channel Tx PCS FPGA Fabric PCIe hard IP Tx PMA Tx Phase Comp FIFO PIPE IF Byte Serializer Tx Output Buffer 8B10B Encoder Serializer The ALTGX megafunction provides a selection of protocol functional modes with predefined settings, according to the protocol requirements for rapid transceiver integration. Table 1–9 shows the modules utilized in the Tx channel when the ALTGX megafunction is configured for each supported protocol functional mode. Table 1–9. Tx Modules Utilization for Supported Protocol Functional Modes in the ALTGX Megafunction Tx Phase Compensation FIFO Byte Serializer 8B10B Encoder Serializer Tx Output Buffer PCI Express (PIPE) v v (1) v v v GIGE v — v v v Functional Mode Note to Table 1–9: (1) This block is not required when using the hard IP implementation of the PCI Express MegaCore function. The following sections describe the functionality of the modules in the Tx channel datapath: ■ Tx Phase Compensation FIFO ■ Byte Serializer ■ 8B10B Encoder ■ Serializer ■ Tx Output Buffer Tx Phase Compensation FIFO The Tx phase compensation FIFO is a required module to compensate for the phase difference when interfacing the Tx PCS with the FPGA fabric directly or through the PIPE interface and PCI Express hard IP block. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–14 Chapter 1: Cyclone IV Transceivers Architecture Tx Datapath Figure 1–7 shows the Tx phase compensation FIFO. Figure 1–7. Tx Phase Compensation FIFO Data input from FPGA fabric or PIPE Interface (tx_datain) Tx Phase Compensation FIFO 8 or 16 wr_clk rd_clk tx_phase_comp_fifo_error 8 or 16 Data output to the Byte Serializer or the 8B10B Encoder tx_clkout tx_coreclk (optional) coreclkout The Tx phase compensation FIFO operates in low-latency or registered mode. Table 1–10 lists the conditions of the Tx phase compensation FIFO when configured in the supported operational modes. Table 1–10. FIFO Conditions in Supported Operational Modes FIFO Modes Depth Latency Functional Mode Low-latency 4 words 2-3 parallel cycles (1) PCI Express (PIPE), GIGE Registered — 1 parallel cycles PCI Express MegaCore function with hard IP Note to Table 1–10: (1) Pending device characterization. You can clock the Tx phase compensation FIFO write clock by enabling the tx_coreclk port in the ALTGX MegaWizard Plug-In Manager interface. Otherwise, the Tx phase compensation FIFO write clock is driven by the FIFO read clock tx_clkout in non-bonded functional modes (such as PCI Express (PIPE) ×1 and GIGE modes) or coreclkout from the Central Control Unit (CCU) in bonded functional modes (such as PCI Express (PIPE) ×4 mode). 1 If you use the tx_coreclk port, ensure that there is a 0 PPM frequency difference between the Tx phase compensation FIFO write and read clock. In the Quartus II software Assignment Editor, use the GXB 0 PPM core clock setting Assignment Name from the tx_coreclk port to the serial output pins. The optional tx_phase_comp_fifo_error signal indicates if the Tx phase compensation FIFO is full or empty. Byte Serializer The byte serializer divides the input datapath by two, allowing you to run the transceiver channel at higher data rates while keeping the FPGA fabric interface frequency within the maximum limit. It converts the 2-byte wide datapath to a 1-byte wide datapath. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Tx Datapath 1–15 The byte serializer is required in configurations that exceed the FPGA fabric-to-transceiver interface maximum frequency, as listed in Table 1–2 on page 1–3. It is optional in configurations that do not exceed this limit. For example, if you want to run the EP4CGX150 device transceiver channel at 3.125 Gbps, the transceiver channel must run at 312.5 MHz (3.125 Gbps/10 bits). This frequency violates the FPGA fabric interface limit of 156.25 MHz. Using the byte serializer, the required frequency is halved to 156.25 MHz (3.125 Gbps/20 bits). The byte serializer forwards the least significant byte first, followed by the most significant byte. Figure 1–8 shows the byte serializer. Figure 1–8. Byte Serializer datain 16 8 dataout Byte Serializer Parallel Clock /2 8B10B Encoder The optional 8B10B encoder generates 10-bit code groups with proper disparity from the 8-bit data and 1-bit control identifier. The encoder is compliant with Clause 36 of the IEEE 802.3 specification. Figure 1–9 shows the 8B10B encoder. Figure 1–9. 8B10B Encoder datain 8 tx_ctrlenable tx_forcedisp 8B10B Encoder dataout 10 tx_dispval Depending on the tx_ctrlenable port, the 8B10B encoder translates the input data to either a 10-bit control or 10-bit data word. The encoder supports the following additional features: ■ Running disparity control with the tx_forcedisp and tx_dispval ports. Use this feature in PCI Express (PIPE) mode for compliance pattern transmission. ■ Transmitter polarity inversion with the tx_invpolarity port to correct accidentally swapped positive and negative signals from the serial differential link. ■ Transmitter bit reversal reverses the transmit bit order in MSB to LSB. The Cyclone IV GX transceiver transmit bit order is LSB to MSB. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–16 Chapter 1: Cyclone IV Transceivers Architecture Tx Datapath ■ 1 Running disparity preservation in GIGE mode to ensure a negative running disparity at the end of an idle ordered set. Any /Dx.y/ (except for /D21.5/ or /D2.2/) following a /K28.5/ is automatically replaced with either of the following: ■ A /D5.6/ (/I1/ ordered set) if the running disparity before /K28.5/ is positive ■ A /D16.2/ (/I2/ ordered set) if the running disparity before /K28.5/ is negative Enable the transmitter bit reversal feature when configuring the ALTGX megafunction for GIGE mode. When configured in GIGE mode, three /K28.5/ comma code groups are transmitted automatically after de-assertion of tx_digitalreset and before transmitting user data on the tx_datain port. This could affect the synchronization state machine behavior at the receiver. Depending on when you start transmitting the synchronization sequence, there could be an even or odd number of /Dx.y/ code groups transmitted between the last of the three automatically sent /K28.5/ code groups and the first /K28.5/ code group of the synchronization sequence. If there is an even number of /Dx.y/ code groups received between these two /K28.5/ code groups, the first /K28.5/ code group of the synchronization sequence begins at an odd code group boundary. An IEEE802.3-compliant GIGE synchronization state machine treats this as an error condition and goes into the Loss-of-Sync state. Figure 1–10 shows an example of even numbers of /Dx.y/ between the last automatically sent /K28.5/ and the first user-sent /K28.5/. The first user-sent /K28.5/ code group received at an odd code group boundary in cycle n + 3 takes the receiver synchronization state machine in Loss-of-Sync state. The first synchronization ordered-set /K28.5/Dx.y/ in cycles n + 3 and n + 4 is discounted and three additional ordered sets are required for successful synchronization. Figure 1–10. Reset Condition in GIGE Mode n n+1 n+2 n+3 n+4 clock tx_digitalreset tx_dataout K28.5 xxx K28.5 K28.5 K28.5 Dx.y Dx.y K28.5 Dx.y K28.5 Dx.y K28.5 Dx.y Serializer The serializer converts the parallel 8-bit or 10-bit data from the transmitter PCS to the serial data. Serial data transmission sequence is LSB to MSB. The serializer operates at a half-clock rate. For example, when it is configured in PCI Express (PIPE) and GIGE Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Tx Datapath 1–17 modes, the Tx serial clocks are at 1.25 GHz and 625 MHz, respectively. Figure 1–11 shows the serializer. Figure 1–11. Serializer Inputs and Outputs Tx PCS 8/10 Tx Output Buffer Tx Serial Clock From MPLL Serializer Tx Load Enable Tx Parallel Clock Tx Output Buffer The Cyclone IV GX Tx output buffer supports pseudo current mode logic (PCML). You can configure the following Tx output buffer features in the ALTGX MegaWizard Plug-In Manager interface: 1 ■ Programmable voltage output differential (V OD ) to customize the differential output voltage that handles different trace lengths, backplanes, and receiver requirements ■ Programmable pre-emphasis with two taps to boost high-frequency components in the transmitted signal that might be attenuated in the transmission media because of data-dependent jitter effects ■ Differential calibrated on-chip termination (OCT) at 100 Ω or 150 Ω ■ On-chip transmitter common mode voltage (V CM ) at 0.65 V ■ Receiver detect function for the PCI Express (PIPE) mode You can disable OCT to use external termination. In such cases, VCM is tri-stated. Figure 1–12. Transmitter Output Buffer GXB_TXp 50 Ω or 75 Ω + VCM- Programmable Pre-emphasis and VOD 50 Ω or 75 Ω GXB_TXn Receiver Detect © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–18 Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath PCI Express Receiver Detect The receiver detection function for PCI Express (PIPE) mode is supported with built-in circuitry, which is active only in the P1 power state with the transmit buffer tri-stated. The circuit detects if there is an active PCI Express receiver downstream by sending a pulse on the common mode of the transmitter and monitoring the reflection. You must select the following settings in the ALTGX MegaWizard Plug-In Manager interface: ■ OCT utilization ■ 125 MHz fixedclk signal The following sequence generates the receiver detect function in PCI Express mode: 1. Drive 1'b1 on the tx_forceelecidle port to put the transmitter buffer in electrical idle (tri-state) mode. 2. Drive the tx_detectrxloopback port to 1'b1. 3. A high pulse on the pipephydonestatus port and 3'b011 on the pipestatus port indicates a receiver is detected. There is some latency after asserting the tx_detectrxloopback signal, before the receiver detection is indicated on the pipephydonestatus port. 1 The tx_forceelecidle port must be asserted at least 10 parallel clock cycles prior to the tx_detectrxloopback port to ensure the transmitter buffer is tri-stated. Rx Datapath Figure 1–13 shows the Rx channel datapath. Figure 1–13. Modules in the Rx Channel Datapath Rx Channel Rx PCS Rate Match FIFO 8B10B Decoder Rx PMA Word Aligner Deserializer Rx Input Buffer FPGA Fabric CDR PCIe hard IP Cyclone IV Device Handbook, Volume 2 PIPE Interface Rx Phase Compen FIFO Byte Deserializer © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath 1–19 Table 1–11 lists the modules used in the Rx channel when the ALTGX megafunction is configured for each supported protocol functional mode. Table 1–11. Rx Modules Uses for the Supported Protocol Functional Modes in the ALTGX Megafunction 8B10B Byte Decoder Deserializer Rx Phase Compensation FIFO Functional Mode Rx Input Buffer CDR Deserializer Word Aligner Rate Match FIFO PCI Express (PIPE) v v v v v v v (1) v GIGE v v v v v v — v Note to Table 1–11: (1) This block is not required when using the hard IP implementation of the PCI Express MegaCore function. The following sections describe the functionality of the modules in the Rx channel datapath: ■ Rx Input Buffer ■ Clock Data Recovery (CDR) ■ Deserializer ■ Word Aligner ■ Rate Match FIFO ■ 8B10B Decoder ■ Byte Deserializer ■ Rx Phase Compensation FIFO Rx Input Buffer The Rx input buffer includes the following features that you can configure in the ALTGX MegaWizard Plug-In Manager interface: ■ Manual equalization circuitry that boosts the high-frequency gain of the incoming signal, thereby compensating for the low-pass filter effects of the physical medium. ■ Programmable DC gain to provide an equal boost to incoming signals across the frequency spectrum. ■ OCT at 100 Ω or 150 Ω ■ Signal detection to determine whether the signal level that is present at the receiver input buffer is above the signal detect threshold voltage. This option is only available for PCI Express (PIPE) mode. The transceiver high-speed serial link supports AC coupling for the PCI Express (PIPE) and GIGE modes. In an AC-coupled link, the AC-coupling capacitor blocks the transmitter DC common mode voltage. On-chip or off-chip receiver termination and biasing circuitry automatically restores the selected common mode voltage. Figure 1–14 shows an AC-coupled link. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–20 Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath Figure 1–14. AC-Coupled Link AC Coupling Capacitor Transmitter Receiver Physical Medium Physical Medium AC Coupling Capacitor RX Termination TX Termination RX VCM TX VCM Clock Data Recovery (CDR) Each Cyclone IV GX receiver channel has a phase interpolator (PI)-based CDR unit to recover the clock from the incoming serial data stream. Each CDR is clocked by dedicated Rx CDR clocks from one of the MPLL within the transceiver block. The CDR works by tracking the incoming data with a phase detector and establishing the optimum sampling clock phase with PI as a recovered serial clock. The recovered serial and parallel clocks are used for clocking the deserializer and receiver PCS blocks. Figure 1–15 illustrates the CDR unit. Figure 1–15. CDR and Deserializer Rx CDR Clock rx_locktorefclk rx_locktodata signal detect rx_freqlocked Recovered Serial Clock LTR/LTD Controller PI Clock Divider Recovered Parallel Clock Sampling Clocks Rx Input Buffer Phase Detector UP DN CDR operates in two states: ■ Lock-to-reference (LTR)—The CDR is tracking the MPLL input reference clock. ■ Lock-to-data (LTD)—Phase detector within the CDR is enabled to track incoming data and determine the optimum sampling clock phase Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath 1–21 There are two operational modes for the CDR unit: ■ Automatic lock mode—The operational states are determined by the LTR/LTD controller. Upon receiver power-up and reset cycle, the CDR is in the LTR state. Transition to the LTD state is performed automatically when both of the following conditions are met: ■ Signal detection circuitry indicates the presence of valid signal levels at the Rx input buffer ■ The CDR output clock is within the configured PPM frequency threshold setting with respect to the MPLL input reference clock Actual lock time depends on the transition density of the incoming data and the PPM difference between the receiver input reference clock and the upstream transmitter reference clock. The CDR transitions from the LTD state to the LTR state when either of the following conditions are met: ■ 1 ■ Signal detection circuitry indicates the absence of valid signal levels at the Rx input buffer ■ The CDR output clock is not within the configured PPM frequency threshold setting with respect to the MPLL input reference clock Manual lock mode—The state of the CDR (either LTR or LTD) is manually controlled with the rx_locktorefclk and rx_locktodata signals. In the PCI Express (PIPE) mode, select the Enable fast recovery mode option in the ALTGX MegaWizard Plug-In Manager to allow the CDR to achieve bit and byte lock when transitioning from the P0s to P0 state within the PCI Express Base Specification. Transitioning from the P0s to P0 state will require the Recovery state if the Enable fast recovery mode option is not selected. Deserializer The deserializer converts received serial data from the Rx input buffer to parallel 8-bit or 10-bit data. Serial data is received from LSB to MSB. The deserializer operates with the half-rate recovered serial clock from the CDR. Figure 1–16 shows the deserializer. Figure 1–16. Deserializer Rx Input Buffer Recovered Serial Clock From CDR Deserializer 8/10 Rx PCS Rx Load Enable Recovered Parallel Clock Word Aligner The optional word aligner restores the word boundary for deserialized parallel data based on a predefined alignment pattern that must be received during link synchronization. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–22 Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath Table 1–12 lists the word aligner configurations when the ALTGX megafunction is configured for each supported protocol functional mode. Table 1–12. Word Aligner Configurations for Supported Protocol Functional Modes Word Aligner Configurations PCI Express (PIPE) GIGE Automatic Synchronization State Machine Automatic Synchronization State Machine 10 bits 7 bits, 10 bits Number of valid synchronization code groups or ordered sets received to achieve synchronization 4 3 Number of erroneous code groups received to lose synchronization 17 4 Number of continuous good code groups received to reduce the error count by one 16 4 Mode Pattern Length The synchronization state machine is compliant with each supported protocol. The word aligner operates with the recovered parallel clock from the CDR. Figure 1–17 shows the word aligner. Figure 1–17. Word Aligner Inputs and Outputs 8/10 datain 8/10 dataout rx_syncstatus rx_patterndetect rx_ctrldetect rx_errdetect rx_disperr rx_runningdisp Word Aligner rx_invpolarity Recovered Parallel Clock After de-assertion of the rx_digitalreset signal, the word aligner identifies the word alignment pattern or synchronization code groups in the received data stream. When the programmed number of valid synchronization code groups or ordered sets is received, it drives the rx_syncstatus signal high, indicating synchronization. The rx_syncstatus signal remains asserted until it receives the specified number of erroneous code groups. The word aligner supports the following additional features: ■ Programmable run length violation detection—Detects and indicates violation of the run length threshold setting with the rx_rlv signal ■ Receiver polarity inversion—Uses the rx_invpolarity port to correct accidentally swapped positive and negative signals from the serial differential link ■ Receiver bit reversal—Reverses the received bit order to MSB to LSB When the 8B10B decoder is enabled, the word aligner checks for the following: ■ Valid control characters with the optional rx_ctrldetect status signal ■ Invalid code groups with the optional rx_errdetect status signal ■ Current running disparity error with the optional rx_disperr status signal Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath ■ 1–23 Current running disparity value with the optional rx_runningdisp status signal Rate Match FIFO The optional rate match FIFO compensates for small clock frequency differences between the upstream transmitter (from the recovered clocks) and the local receiver reference clock domain. This process is achieved by performing the following: ■ Inserting skip (SKP) symbols or ordered sets when the local receiver reference clock frequency is greater than the upstream transmitter reference clock frequency ■ Deleting SKP symbols or ordered-sets when the local receiver reference clock frequency is less than the upstream transmitter reference clock frequency Figure 1–18 illustrates the rate match FIFO. Figure 1–18. Rate Match FIFO Inputs and Outputs rx_syncstatus Rate Match FIFO datain 10 dataout 10 wrclk Recovered Parallel Clock rdclk Tx Parallel Clock Rate Match FIFO in PCI Express (PIPE) Mode The rate match FIFO can compensate for up to ±300 PPM (600 PPM total) difference between the upstream transmitter and the local receiver. The rate match FIFO operation is compliant with the PCI Express Base Specification 1.1. The rate match operation begins after the synchronization state machine in the word aligner drives the rx_syncstatus signal high, indicating synchronization is acquired. 1 Select the Enable low latency synchronous PCI Express (PIPE) option in the ALTGX MegaWizard Plug-In Manager if your system uses common reference clocking that gives a 0 ppm difference between the upstream transmitter ’s and local receiver’s reference clock. When enabled, the rate match FIFO is configured with reduced latency. Rate Match FIFO in GIGE Mode The rate match FIFO can compensate for up to ±100 PPM (200 PPM total) difference between the upstream transmitter and the local receiver reference clock. The rate match FIFO is compliant with the IEEE 802.3 Specification. Rate match operation begins after the synchronization state machine in the word aligner drives the rx_syncstatus signal high, indicating synchronization has been acquired. 8B10B Decoder The optional 8B10B decoder receives 10-bit data from the rate matcher and decodes it into an 8-bit data and 1-bit control identifier. The 8B10B decoder is compliant to Clause 36 of the IEEE 802.3 Specification. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–24 Chapter 1: Cyclone IV Transceivers Architecture Rx Datapath Byte Deserializer The optional byte deserializer reduces the FPGA fabric–transceiver interface frequency by half while doubling the parallel data width. The byte deserializer receives 8-bit wide data from the 8B10B decoder and deserializes it into a 16-bit wide data at half the speed. Rx Phase Compensation FIFO The Rx phase compensation FIFO is a required module to compensate for the phase difference when interfacing the Rx PCS with the FPGA fabric directly or through the PIPE interface and PCI Express hard IP block. The Rx phase compensation FIFO operates in low-latency or registered modes. Table 1–13 lists the conditions of the Rx phase compensation FIFO when configured in the supported operational modes. Table 1–13. FIFO Conditions in Supported Operational Modes FIFO Modes Depth Latency Functional Mode Low-latency 4 words 2-3 parallel cycles (1) PCI Express (PIPE), GIGE Registered — 1 parallel cycle PCI Express MegaCore function with hard IP Note to Table 1–13: (1) Pending device characterization. You can clock the Rx phase compensation FIFO read clock by enabling the rx_coreclk port in the ALTGX MegaWizard Plug-In Manager interface. Otherwise, the Rx phase compensation FIFO read clock is driven by the tx_clkout port in non-bonded functional modes (such as PCI Express [PIPE] ×1 and GIGE modes) or coreclkout from the CCU in bonded functional modes (such as PCI Express [PIPE] ×4 mode). 1 If you use the rx_coreclk port, ensure that there is a 0 PPM frequency difference between the Rx phase compensation FIFO write and read clock. In the Quartus II software Assignment Editor, use the GXB 0 PPM core clock setting Assignment Name from the rx_coreclk port to the serial input pins. The optional rx_phase_comp_fifo_error signal provides an indicator if the Rx phase compensation FIFO is full or empty. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Clocking 1–25 Clocking The transceiver channels are primarily driven by clocks from the MPLLs within the same transceiver block. Cyclone IV GX transceivers support flexible clocking architecture that allows implementation of multiple protocols, while fully utilizing all available transceiver resources. For example, you can use one of the MPLL to drive the Tx and the Rx channels at the same rates, while the remaining MPLL can be used as a GPLL. In addition, the architecture allows independent transmit and receive frequencies. Each Tx channel operates with high-speed serial and low-speed parallel clocks from one of the two MPLLs. For Rx channels, the CDRs are fed by a segmented clock network, as shown in Figure 1–19. The Rx CDR clock from each MPLL must drive a number of contiguous segmented paths to reach the intended Rx channels. For example, MPLL1 can drive contiguous Rx channels 0 and 1, while MPLL2 drives contiguous Rx channels 2 and 3 at the same time. 1 Interleaving the Rx CDR clock source from the two MPLLs is not supported. As For example, a combination of MPLL1 driving Rx channels 0, 1 and 3, while MPLL2 driving Rx channel 2 is not supported. In this case, only one MPLL can be used for the Rx channels. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–26 Chapter 1: Cyclone IV Transceivers Architecture Clocking The input reference clock for the MPLLs are provided through the REFCLK pins residing in Banks 3A, 3B, 8A, and 8B. When the MPLLs are not used for transceivers, they can be used as GPLLs. Figure 1–19 shows the transceiver clock distribution for one transceiver block in Cyclone IV GX devices. Figure 1–19. Transceiver Clock Distribution for Cyclone IV GX Devices with One Transceiver Block Transmitter Channels GXBL0 3 (1) 3 (1) GXBL0 (2) MPLL2 MPLL1 Receiver Channels MPLL2 Ser Ch3 Tx CDR Ch3 Rx Ser Ch2 Tx CDR Ch2 Rx Ser Ch1 Tx CDR Ch1 Rx Ser Ch0 Tx CDR Ch0 Rx MPLL1 Notes to Figure 1–19: (1) These dedicated buses contain the Tx serial clock, Tx load enable, and Tx parallel clock. (2) This dedicated signal is the Rx CDR clock. Depending on the transceiver configurations, each clock segment is enabled automatically by the Quartus II software. You can drive transceiver channels by clocks from the GPLLs, in addition to the MPLLs in Cyclone IV GX devices with two transceiver blocks, as shown in Figure 1–20. GPLLs provide the serial and parallel clocks to adjacent transceiver block only, with the exception of the CDR clock. Serial and parallel clocks from MPLL6 and MPLL7 can be shared by neighboring transceiver blocks for increased clocking flexibility. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Clocking 1–27 Figure 1–20. Transceiver Clock Distribution for Cyclone IV GX Devices with Two Transceiver Blocks GPLL2 3 (1) 3 (1) Transmitter Channels GXBL1 Receiver Channels GXBL1 (2) MPLL8 Ser Ch3 Tx CDR Ch3 Rx Ser Ch2 Tx CDR Ch2 Rx Ser Ch1 Tx CDR Ch1 Rx Ser Ch0 Tx CDR Ch0 Rx MPLL7 MPLL7 3 MPLL8 (1) 3 (2) MPLL6 3 3 (1) (1) GXBL0 GXBL0 (1) MPLL5 MPLL6 Ser Ch3 Tx CDR Ch3 Rx Ser Ch2 Tx CDR Ch2 Rx Ser Ch1 Tx CDR Ch1 Rx Ser Ch0 Tx CDR Ch0 Rx MPLL5 GPLL1 Notes to Figure 1–20: (1) These dedicated buses contain the Tx serial clock, Tx load enable, and Tx parallel clock. (2) This dedicated signal is the Rx CDR clock. Depending on the transceiver configurations, each clock segment is enabled automatically by the Quartus II software. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–28 Chapter 1: Cyclone IV Transceivers Architecture Clocking The REFCLK pins support AC-coupling connections for LVDS, LVPECL, and PCML (1.2V, 1.5V, 3.3V) differential I/O standards, and DC-coupling connections for HCSL I/O standards. Figure 1–21 shows an example termination scheme for AC-coupled connections for REFCLK pins. Figure 1–21. AC-Coupled Termination Scheme for a Reference Clock LVDS, LVPECL, PCML (1.2 V, 1.5 V, 3.3 V) 0.1 μF Z0 = 50 Ω 0.1 μF Cyclone IV GX REFCLK VICM Z0 = 50 Ω 50 Ω 50 Ω Note to Figure 1–21: (1) VICM can be sourced from the 2.5 V supply with a voltage divider circuit (typically two 1-kΩ resistors). Figure 1–22 shows an example termination scheme for a clock signal when configured as High-Speed Current Steering Logic (HCSL). Figure 1–22. Termination Scheme for a Reference Clock When Configured as HCSL (Note 1) Cyclone IV GX REFCLK + Rs (2) PCI Express (HCSL) REFCLK Source Rs (2) REFCLK 50 Ω 50 Ω Notes to Figure 1–22: (1) No biasing is required if the reference clock signals are generated from a clock source that conforms to the PCI Express specification. (2) Select values as recommended by the PCI Express clock source vendor Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Clocking 1–29 Figure 1–23 shows the clocking architecture for transceivers in non-bonded configurations. Figure 1–23. Example Transceiver Clocking Architecture in a Non-Bonded Configurations Transmitter Channel PCS rdclk wrclk rdclk Tx Parallel Clock tx_clkout[0] Tx Serial Clock /2 Word Aligner Receiver Channel PMA Rate Match FIFO 8B10B Decoder Byte Deserializer Receiver Channel PCS Rx Phae Comp FIFO PIPE Interface /2 rx_coreclk[0] Serializer 8B10B Encoder Byte Serializer CDR wrclk PCI Express hard IP tx_coreclk[0] Tx Phase Comp FIFO Transmitter Channel PMA Deserializer FPGA Fabric Parallel Recovered Clock Tx Parallel Clock When the transceivers are configured in bonded modes, the clock and reset signals are common for each bonded channel to minimize lane-to-lane skew. Figure 1–24 and Figure 1–25 show the clocking architecture for transceivers in bonded configurations. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–30 Chapter 1: Cyclone IV Transceivers Architecture Clocking Figure 1–24. Example Transmitter Clocking Architecture in a Bonded Configuration PIPE Interface tx_coreclk[3] PCI Express hard IP Tx Phase Comp FIFO wrclk Byte Serializer rdclk wrclk Channel 3 Transmitter Channel PMA Channel 2 Transmitter Channel PMA Serializer Transmitter Channel PCS FPGA Fabric 8B10B Encoder rdclk Transmitter Channel PCS PIPE Interface tx_coreclk[2] PCI Express hard IP Tx Phase Comp FIFO wrclk Byte Serializer rdclk wrclk Serializer /2 8B10B Encoder rdclk /2 Central Control Unit (CCU) Tx Parallel Clock coreclkout FPGA Fabric-Transceiver Interface Clock /2 PIPE Interface tx_coreclk[1] PCI Express hard IP Tx Phase Comp FIFO wrclk rdclk Byte Serializer wrclk Channel 1 Transmitter Channel PMA Channel 0 Transmitter Channel PMA Serializer Transmitter Channel PCS Tx Serial Clock 8B10B Encoder rdclk Transmitter Channel PCS PIPE Interface tx_coreclk[0] PCI Express hard IP Cyclone IV Device Handbook, Volume 2 Tx Phase Comp FIFO wrclk rdclk Byte Serializer wrclk 8B10B Encoder Serializer /2 rdclk /2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Loopback 1–31 Figure 1–25. Example Receiver Channels Clocking Architecture in a Bonded Configuration /2 /2 CDR Deserializer Serial Recovered Clock Channel 2 Receiver Channel PMA CDR Deserializer Word Aligner Rate Match FIFO 8B10B Decoder Byte Deserializer Rx Phase Comp FIFO rx_coreclk[2] PIPE Interface Receiver Channel PMA Ch3 Parallel Recovered Clock Receiver Channel PCS PCI Express hard IP Channel 3 Word Aligner Rate Match FIFO Byte Deserializer rx_coreclk[3] PIPE Interface Rx Phase Comp FIFO PCI Express hard IP 8B10B Decoder Receiver Channel PCS FPGA Fabric Serial Recovered Clock Ch2 Parallel Recovered Clock Rx CDR Clock Central Control Unit (CCU) coreclkout FPGA Fabric-Transceiver Interface Clock Tx Parallel Clock /2 /2 /2 CDR Deserializer Serial Recovered Clock Channel 0 Receiver Channel PMA CDR Deserializer Word Aligner Rate Match FIFO 8B10B Decoder Byte Deserializer Rx Phase Comp FIFO rx_coreclk[0] PIPE Interface Receiver Channel PMA Ch1 Parallel Recovered Clock Receiver Channel PCS PCI Express hard IP Channel 1 Word Aligner Rate Match FIFO 8B10B Decoder rx_coreclk[1] PIPE Interface Rx Phase Comp FIFO PCI Express hard IP Byte Deserializer Receiver Channel PCS Serial Recovered Clock Ch0 Parallel Recovered Clock Loopback Cyclone IV GX devices provide three loopback options that allow you to verify the operation of different functional blocks in the transceiver channel. The following loopback modes are available: ■ Reverse parallel loopback (available only for PCI Express [PIPE] mode) ■ Serial loopback (available for all modes except PCI Express [PIPE] mode) ■ Reverse serial loopback © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–32 Chapter 1: Cyclone IV Transceivers Architecture Loopback Reverse Parallel Loopback Mode In reverse parallel loopback mode, the received data is looped back to the transmitter serializer after the rate match FIFO and then transmitted as serial data, as shown in Figure 1–26. The received data is also available to the FPGA fabric through the rx_dataout port. This loopback mode is compliant with the PCI Express Base Specification 1.1. To enable the reverse parallel loopback mode, assert the tx_detectrxloopback port in P1 power state. In loopback mode, you can write your own test program to verify the Rx datapath and operation of the Tx PMA functionality. Figure 1–26. PCI Express (PIPE) Reverse Parallel Loopback Path Transceiver Tx PMA Tx PCS FPGA Fabric PCIe hard IP Serializer Reverse parallel loopback path PIPE IF Rx PMA Rx PCS Rate Match FIFO Word Aligner Deserializer CDR Serial Loopback Mode In serial loopback mode, the transmitter data is looped back to the receiver CDR after the serializer, as shown in Figure 1–27. The received data is available to the FPGA logic for verification. With this option, you can check the operation of all enabled PCS and PMA functional blocks in the transmitter and receiver channels. The transmitter channel sends the data to both the serial output port and the receiver channel. The differential output voltage on the serial ports is based on the selected VOD settings. The data is looped back to the receiver CDR and is retimed through different clock domains. You must provide an alignment pattern for the word aligner to enable the receiver channel to retrieve the byte boundary. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Calibration 1–33 Figure 1–27. Serial Loopback Path Transceiver Tx PMA Tx PCS Serializer FPGA Fabric Serial loopback Rx PMA To FPGA fabric for verification Rx PCS CDR Deserializer Reverse Serial Loopback Mode The two reverse serial loopback modes from the receiver to the transmitter are: ■ Pre-CDR mode from the Rx input buffer directly to the Tx output buffer with the Reverse serial loopback (pre-CDR) option ■ Post-CDR mode from the CDR to the Tx output buffer with the Reverse serial loopback option Figure 1–28 shows the two paths in reverse serial loopback mode. Figure 1–28. Reverse Serial Loopback Transceiver Tx PMA Tx PCS FPGA Fabric To FPGA Fabric for Verification Serializer (1) Rx PCS Deserializer (2) CDR Rx PMA Notes to Figure 1–28: (1) Post-CDR reverse serial loopback path. (2) Pre-CDR reverse serial loopback path. Calibration The calibration circuitry calibrates the OCT resistors for Tx and Rx termination. It compensates for process, voltage, and temperature variations. Calibration always occurs after power-up or channel reset. Figure 1–29 shows the required inputs to the calibration block. All transceiver channels use the same calibration block clock and power down signals. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–34 Chapter 1: Cyclone IV Transceivers Architecture Reset Control You must connect a 2 kΩ (maximum tolerance is ± 1%) external resistor to the RREF pin of the Cyclone IV GX device to GND. To ensure proper operation of the calibration block, the RREF resistor connection on the board must be free from external noise. During normal operation, you can recalibrate the termination resistors with the cal_blk_powerdown port available through the ALTGX MegaWizard Plug-In Manager interface. Following de-assertion of cal_blk_powerdown, the calibration block restarts the calibration process. Figure 1–29. Calibration Block Inputs and Outputs Channel 3 OCT Calibration Control Channel 2 RREF pin 2k Ω ±1% cal_blk_clk cal_blk_powerdown Calibration Block Channel 1 Channel 0 Reset Control Cyclone IV GX devices includes several reset signals to control the transceiver channels. The ALTGX MegaWizard Plug-In Manager interface allows you to configure individual reset signals for each channel instantiated in the design. There is also a power down signal for each transceiver block. Figure 1–30 shows the inputs to the reset controller. For descriptions of these signals, refer to the appropriate table under “Top-Level Signals” on page 1–4. Figure 1–30. Inputs to the Reset Controller tx_digitalreset rx_digitalreset rx_analogreset Reset Controller pll_powerdown gxb_powerdown Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Reset Control 1–35 Table 1–14 lists the blocks that are affected by specific reset and power-down signals. Table 1–14. Blocks Affected by the Reset and Power-Down Signals Transceiver Module rx_digitalreset rx_analogreset tx_digitalreset pll_powerdown gxb_powerdown MPLL — — — v — Tx Phase Comp FIFO — — v — v Tx Byte Serializer — — v — v Tx 8B10B Encoder — — v — v Tx Serializer — — v — v Tx HSSI I/O Buffer — — — — v Rx HSSI I/O Buffer — — — — v Rx CDR — v — — v Rx Deserializer — — — — v Rx Word Aligner v — — — v Rx Rate Match FIFO v — — — v Rx 8B10B Decoder v — — — v Rx Byte Deserializer v — — — v Rx Phase Comp FIFO v — — — v PCI Express hard IP — — — — v PIPE Interface — — — — v © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–36 Chapter 1: Cyclone IV Transceivers Architecture Reset Control PCI Express (PIPE) Mode Reset Sequence Figure 1–31 shows the recommended reset sequence for PCI Express (PIPE) mode. Figure 1–31. PCI Express (PIPE) Mode Reset Sequence Initialization/Compliance Phase Normal Operation Reset & Power Down: 1 μs pll_powerdown tx_digitalreset rx_analogreset > 2 parallel clock cycles rx_digitalreset Output Status: pll_locked > 4 μs ignore received data > 4 μs rx_freqlocked Initialization/Compliance Phase Use the following reset sequence during the initialization/compliance phase: 1. After power up, assert pll_powerdown for a minimum period of 1 µs. Keep the tx_digitalreset, rx_analogreset, and rx_digitalreset signals asserted during this time period. After you de-assert the pll_powerdown signal, the MPLL starts locking to the input reference clock. 2. When the MPLL locks, as indicated by the pll_locked signal going high, de-assert tx_digitalreset, rx_analogreset, and rx_digitalreset. 3. After de-asserting rx_digitalreset, the pipephydonestatus signal from the transceiver channel is asserted, indicating the status to the link layer. Depending on its status, pipephydonestatus helps continue the compliance phase. After successful completion of this phase, the device enters into the normal operation phase. 1 During the initialization/compliance phase, do not use the rx_freqlocked signal to trigger a de-assertion of the rx_digitalreset signal. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Reset Control 1–37 Normal Operation Phase After completion of the initialization/compliance phase, proceed with the reset sequence after re-assertion of the rx_freqlocked signal. Wait for at least 4 µs before asserting rx_digitalreset for two parallel receive clock cycles so that the Rx phase compensation FIFO is initialized. 1 Data from the transceiver block is not valid from the time the rx_freqlocked signal goes low to the time rx_digitalreset is de-asserted. Cyclone IV GX devices fulfill the PCI Express reset time requirement from device power up to the link active state with the configuration schemes listed in Table 1–15. Table 1–15. Typical Configuration Times for each Cyclone IV Device with Selected Configuration Scheme for the PCI Express (PIPE) Mode Device Configuration Scheme Configuration Time (ms) EP4CGX15 Passive Serial 51 EP4CGX22 Passive Serial 92 EP4CGX30 Passive Serial 92 EP4CGX50 Fast Passive Parallel 41 EP4CGX75 Fast Passive Parallel 41 EP4CGX110 Fast Passive Parallel 70 EP4CGX150 Fast Passive Parallel 70 GIGE Reset Sequence Figure 1–32 shows the recommended reset sequence for GIGE mode with Transmitter Only channel setup. Figure 1–32. GIGE Reset Sequence with Transmitter Only Channel Mode Reset & Power Down: 1 μs pll_powerdown tx_digitalreset Output Status: pll_locked © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–38 Chapter 1: Cyclone IV Transceivers Architecture Power Down Figure 1–33 shows the recommended reset sequence for GIGE mode with Receiver and Transmitter channel setup. Figure 1–33. GIGE Reset Sequence with Receiver and Transmitter Channel Setup Reset & Power Down: 1 μs pll_powerdown tx_digitalreset rx_analogreset rx_digitalreset Output Status: pll_locked > 4 μs rx_freqlocked Power Down The Quartus II software automatically powers down all unused transceiver channels and blocks to reduce overall power consumption. The optional gxb_powerdown transceiver signal powers down all transceiver channels and all functional blocks in the transceiver block. Figure 1–34 shows a sample reset sequence of GIGE mode with Receiver and Transmitter channel setup using the optional gxb_powerdown signal. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Parameter Settings 1–39 Figure 1–34. GIGE Mode Reset Sequence with Receiver and Transmitter Channel Setup with the Optional gxb_powerdown Signal Reset & Power Down: 1 μs pll_powerdown 1 μs gxb_powerdown tx_digitalreset rx_analogreset rx_digitalreset Output Status: pll_locked > 4 μs rx_freqlocked Parameter Settings This section describes the ALTGX megafunction parameters that you can set using the MegaWizard Plug-In Manager interface. The ALTGX MegaWizard Plug-In Manager interface displays the following wizard pages: ■ General ■ PLL/Ports ■ Ports/Cal Blk ■ Loopback ■ Rx Analog ■ Tx Analog © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–40 Chapter 1: Cyclone IV Transceivers Architecture Parameter Settings General The General page allows you to specify fundamental options about the ALTGX megafunction. Table 1–16 describes the settings available for the General page. Table 1–16. General Settings for the ALTGX Megafunction Parameter Values Which protocol will you be using? PCI Express (PIPE) Description Determines the specific protocol or mode under which the transceiver operates. GIGE Which subprotocol will you be using? Gen1 ×1 Gen1 ×4 For PCI Express (PIPE) mode, you can select ×1 or × 4 operation. You do not have to specify a sub-protocol for GIGE mode. Enforce default settings for this protocol On/Off If you turn on this option, the specified frequencies and data rates for the selected protocol are specified for you. What is the operation mode? Transmitter Only, For PCI Express (PIPE) mode, only the Receiver and Transmitter (full duplex) mode is allowed. For GIGE mode, you can select either a Receiver and transmitter, or receiver and transmitter. Transmitter What is the number of channels? 1–4 What is the deserializer block width? Single Double For PCI Express (PIPE) mode, you can specify ×1 or ×4 operation. The channels must be identical. You can specify 1-4 channels for GIGE mode. This option sets the transceiver datapath width. ■ Single width—This mode operates from 600 Mbps to 3.125 Gbps. The features of each block may differ from the double-width mode. ■ Double width—This mode operates at data rates > 1 Gbps. The features of each block in this mode may differ from the single-width mode. For Cyclone IV transceivers, only single-width is supported. What is the channel width? 8 16 This option determines the transceiver-to-FPGA interface width. ■ If you select 8, the byte serializer/deserializer is not used. ■ If you select 16, the byte serializer/deserializer is used. What would you like to base the setting on? Data Rate This option is not configurable because the data rate is fixed at 2.5 Gbps for PCI Express (PIPE) mode and 1.25 Gbps for GIGE mode. What is the data rate? 2500 Mbps 1250 Mbps This option is not used because the data rate is fixed at 2.5 Gbps for PCI Express (PIPE) mode and 1.25 Gbps for GIGE mode. What is the input clock frequency? 62.5 MHz 100 MHz 125 MHz Determines the input reference clock frequency for the transceiver. The base data is Cyclone IV Device Handbook, Volume 2 Mbps ■ In PCI Express (PIPE) mode, only 100 MHz is allowed. 125 MHz will be supported in a future version of the Quartus II software. ■ In GIGE mode, 62.5 MHz and 125 MHz are allowed. This option is not configurable because the data rate is fixed at 2.5 Gbps for PCI Express (PIPE) mode and 1.25 Gbps for GIGE mode. © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Parameter Settings 1–41 PLL/Ports Table 1–17 describes the settings available on the PLL/Ports page. Table 1–17. PLL/Ports Settings (Part 1 of 2) Parameter Value Description PLL Settings Train Receiver CDR from pll_inclk On/Off This option is always On for Cyclone IV GX transceivers. When On, CDR trains using pll_inclk that you provide to the MPLL. Use Auxiliary Transmitter (ATX) PLL On/Off This option is not available for Cyclone IV GX devices. Enable PLL PFD Feedback to compensate latency uncertainty in Tx dataout and Tx clkout paths relative to the reference clock On/Off This option is not available for Cyclone IV GX transceivers. What is the Tx/Rx PLL bandwidth mode? Auto, High, Medium, Low This option allows you to tune analog settings in the PLL to control how quickly the PLL adjusts to changes in the input clock. A high bandwidth PLL provides fast lock time and tracks jitter on the reference clock source, passing it through to the PLL output. A low bandwidth PLL filters out reference clock jitter, but increases lock time. The default setting for PCI Express (PIPE) and GIGE mode is Auto, which allows the PLL to calculate the optimal setting. What is the receiver CDR bandwidth mode? Auto, High, Medium, Low This option is not available for Cyclone IV GX transceivers. What is the acceptable PPM threshold between the receiver CDR VCO and the receiver input reference clock? ±100 ±300 This option specifies the PPM difference between the MPLL input reference clock and the CDR recovered clock. For PCI Express (PIPE) mode, this field must be set to ±300. For GIGE mode, this field must be set to ±100. Optional Ports Create ‘gxb_powerdown’ port to power down the Transceiver block On/Off The optional gxb_powerdown transceiver signal powers down all transceiver channels and all functional blocks in the transceiver block. Create ‘pll_powerdown’ port to power down the Tx/Rx MPLL On/Off The pll_powerdown signal is optional. This port is enabled if you select Enforce default settings for this protocol for PCI Express (PIPE) and GIGE modes. Create ‘rx_analogreset’ port for the analog portion of the receiver On/Off The rx_analogreset port is optional. This port is enabled if you select Enforce default settings for this protocol for PCI Express (PIPE) and GIGE modes. Create ‘rx_digitalreset’ port for the digital portion of the receiver On/Off The rx_digitalreset port is optional. This port is enabled if you select Enforce default settings for this protocol for PCI Express (PIPE) and GIGE modes. Create ‘tx_digitalreset’ port for the digital portion of the transmitter On/Off The tx_digitalreset port is optional. This port is enabled if you select Enforce default settings for this protocol for PCI Express (PIPE) and GIGE modes. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–42 Chapter 1: Cyclone IV Transceivers Architecture Parameter Settings Table 1–17. PLL/Ports Settings (Part 2 of 2) Parameter Value Description Create ‘pll_locked’ port to indicate MPLL is locked to the reference input clock On/Off The optional pll_locked signal is useful for debugging. Create ‘rx_locktorefclk’ port to lock the Rx CDR to the reference clock On/Off The optional rx_locktorefclk signal is useful for debugging. Create ‘rx_locktodata’ port to lock the Rx CDR to the received data On/Off The optional rx_locktodata signal is useful for debugging. Create ‘rx_pll_locked’ port to indicate Rx CDR is locked to the input reference clock On/Off This optional signal is not available for Cyclone IV GX transceivers. Ports/Cal Blk Table 1–18 describes the settings available on the Ports/Cal Blk page. Table 1–18. Ports/Cal Blk Settings Parameter Value Description Create ‘rx_signaldetect’ port to indicate data input signal detection On/Off This optional signal is only available for PCI Express (PIPE) mode. When asserted, this indicates that the signal present at the receiver input buffer is above the programmed signal detection threshold value. It is useful for debugging. Enable Tx Phase Comp FIFO in register mode On/Off This option is not available for PCI Express (PIPE) and GIGE mode. Create ‘debug_rx_phase_ comp_fifo_error’ output port On/Off This optional output port indicates a Rx phase compensation FIFO overflow or under run condition. Note that no PPM difference is allowed between the FIFO read and write clocks. Use this port for debug purpose only. Create ‘debug_tx_phase_ comp_fifo_error’ output port On/Off This optional output port indicates Tx phase compensation FIFO overflow/under run condition. Note that no PPM difference is allowed between FIFO read and write clocks. Used this port for debug purpose only. Create ‘rx_coreclk’ port to connect to the read clock of the Rx phase compensation FIFO On/Off This optional input port allows you to clock the read side of the Rx phase compensation FIFO with a non-transceiver FPGA clock. For more information refer to “Tx Phase Compensation FIFO” on page 1–13. Create ‘tx_coreclk’ port to connect to the write clock of the Tx phase compensation FIFO On/Off This optional input port allows you to clock the write side of the Tx phase compensation FIFO with a non-transceiver FPGA clock. Create ‘rateswitch’ port to divide down the data rate On/Off This option is not available for Cyclone IV GX transceivers. Use calibration block On/Off The calibration circuitry calibrates the OCT resistors for Tx and Rx termination. Create active high ‘cal_blk_powerdown’ port to power down the calibration block On/Off Use this signal to recalibrate the termination resistors during normal operation. For more information, refer to “Calibration” on page 1–33. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Parameter Settings 1–43 Loopback Table 1–19 describes the settings available on the Loopback page. Table 1–19. Loopback Settings Parameter Loopback Options Reverse Loopback Options Value Description No loopback Serial loopback Use this option to enable the reverse serial loopback that sends serial signals from the receiver to transmitter directly. Serial loopback is available for all modes except PCI Express (PIPE) mode. Reverse serial loopback (pre-CDR) When enabled, signals are driven back to the sender, allowing you to verify basic functionality. Reverse serial loopback No reverse loopback Rx Analog Table 1–20 describes the settings available on the Rx Analog page. Table 1–20. Rx Analog Settings Parameter Value Description Enable static equalizer control On/Off 0–High This option enables the static equalizer settings. When this option is On, you can select the equalization setting. What is the DC gain? 0, 1, 3 For PCI Express (PIPE) mode a DC gain setting of 1 is required. For GIGE mode, all these settings are available. What is the receiver common mode voltage (Rx VCM) 0.82V Cyclone IV GX transceivers only support Rx VCM of 0.82 V. Force signal detection On/Off This option is available for PCI Express (PIPE) mode. For more information, refer to the definition of rx_signaldetect in Table 1–4. What is the signal detect and signal loss threshold. 4 When the forced signal detection option is Off, use this option to set the trip point of the signal detect circuit. Use external receiver termination On/Off This option is available if you want to use an external termination resistor instead of the OCT. If you turn on this option, the receiver OCT is not used. What is the receiver termination resistance? 100 Ω This option specifies the receiver termination value. 150 Ω Tx Analog Table 1–21 describes the settings available on the Tx Analog page. Table 1–21. Tx Analog Settings (Part 1 of 2) Parameter Value Description What is the transmitter common mode voltage (VCM) 0.65V Cyclone IV GX transceivers only support Tx VCM of 0.65 V. Use external transmitter termination On/Off This option is available if you want to use an external termination resistor instead of the OCT. If you turn on this option, the transmitter OCT is not used. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 2 1–44 Chapter 1: Cyclone IV Transceivers Architecture Protocol Settings Table 1–21. Tx Analog Settings (Part 2 of 2) Parameter Value 100 Ω Select the transmitter termination resistance This option specifies the transmitter termination value. 150 Ω 1-6 What is the voltage output differential (VOD) control setting? What is the pre-emphasis setting (% of Vod)? Description This option specifies the VOD of the transmitter buffer. 1, 5, 9, 13, 16, This option sets the amount of pre-emphasis on the transmitter 17, 18, 19, 20, 21 buffer for the first tap. Protocol Settings You can use protocol settings to specify parameters that are specific to a particular protocol. Table 1–22 describes the first page of protocol settings for PCI Express (PIPE) mode. Table 1–22. PCI Express (PIPE) Mode Settings (Part 1 of 2) Parameter Value Description Optional Settings Enable low latency synchronous PCI Express (PIPE) On/Off When this option is turned On, the rate match FIFO is configured with a reduced latency setting. Use this option for systems that operate using common reference clocking with 0 ppm difference between the upstream transmitter’s and the local receiver’s reference clock. Enable run-length violation checking with a run length of On/Off 40-80 When enabled, rx_rlv is asserted when the number of consecutive 1s or 0s in the received data stream exceeds the programmed run length violation threshold. Enable fast recovery mode On/Off When Enable fast recovery mode is turned On, the MegaCore enables circuitry for a faster exit from the P0s state. When turned Off, exit from P0s typically requires invoking link recovery. Enable electrical idle inference functionality On/Off Enables inference of electrical idle. Cyclone IV Device Handbook, Volume 2 © November 2009 Altera Corporation Chapter 1: Cyclone IV Transceivers Architecture Protocol Settings 1–45 Table 1–22. PCI Express (PIPE) Mode Settings (Part 2 of 2) Parameter Value Description Optional Ports Create ‘rx_syncstatus’ output port for pattern detector and word aligner On/Off Create ‘rx_patterndetect’ port to indicate the pattern detected On/Off Create ‘rx_ctrldetect’ port to indicate the 8B10B decoder has detected a control code On/Off Create ‘tx_detectrxloop’ input port as receiver detect or loopback enable depending on the power state On/Off Create ‘tx_forceelecidle’ input port to force the transmitter to send electrical idle signals On/Off Create ‘tx_forcedispcompliance’ input port to force negative running disparity On/Off Create ‘tx_invpolarity’ to allow transmitter polarity inversion On/Off For additional information about these signals, refer to “Top-Level Signals” on page 1–4. Table 1–23 describes the second page of protocol settings for PCI Express (PIPE) mode. Table 1–23. PCI Express (PIPE) 2 Settings Parameter Value Create ‘pipestatus’ output port for PIPE interface status signal On/Off Create ‘pipedatavalid’ output port to indicate valid data from the receiver On/Off Create ‘pipelecide’ output port for electrical idle detect status signal On/Off Create ‘pipephydonestatus’ output port to indicate PIPE completed power sate transitions On/Off Create ‘pipe8b10binvpolarity’ to enable polarity inversion in PIPE On/Off Create ‘powerdn’ input port for PIPE powerdown directive On/Off © November 2009 Altera Corporation Description For additional information about these signals, refer to “Top-Level Signals” on page 1–4. Cyclone IV Device Handbook, Volume 2 1–46 Chapter 1: Cyclone IV Transceivers Architecture Protocol Settings Table 1–24 describes the protocol settings for GIGE. Table 1–24. GIGE Settings Parameter Value Description Create ‘rx_syncstatus’ output port for pattern detector and word aligner On/Off Create ‘rx_patterndetect’ port to indicate the pattern detected On/Off Create ‘rx_invpolarity’ to enable word aligner polarity inversion On/Off Create ‘rx_ctrldetect’ port to indicate the 8B10B decoder has detected a control code On/Off Create ‘rx_errdetect’ input port as receiver detect or loopback enable depending on the power state On/Off Create ‘rx_disperr’ to indicate the 8B10B decoder has detected a disparity error On/Off Create ‘tx_invpolarity’ to allow transmitter polarity inversion On/Off Create ‘rx_runningdisp’ port to indicate the current running disparity of the 8B10B decoded byte On/Off Create ‘rx_rmfifofull’ port to indicate when the rate match FIFO is full On/Off Create ‘rx_rmfifoempty’ port to indicate when the rate match FIFO is empty On/Off Create ‘rx_rmfifodatainserted’ port to indicate when data is inserted in the rate match FIFO On/Off Create ‘rx_rmfifodatadeleted’ port to indicate when data is deleted in the rate match FIFO On/Off Enable transmitter bit reversal On/Off The normal order for bit transmission is LSB to MSB. When this option is On, the transmission order is MSB to LSB. What is the word alignment pattern length? 7, 10 Specifies the word alignment pattern length. Cyclone IV Device Handbook, Volume 2 For additional information about these signals, refer to “Top-Level Signals” on page 1–4. . © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 101 Innovation Drive San Jose, CA 95134 www.altera.com CYIV-5V3-1.0 Copyright © 2009 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. RSDS and PPDS are registered trademarks of National Semiconductor. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Contents Chapter Revision Dates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Additional Information About this Handbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v How to Contact Altera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v Typographic Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Info-v Section 1. Device Datasheet Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Chapter 1. Cyclone IV Device Datasheet Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Maximum Allowed Overshoot or Undershoot Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Supply Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Bus Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 OCT Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Pin Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8 Internal Weak Pull-Up and Weak Pull-Down Resistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 Hot-Socketing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Schmitt Trigger Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 I/O Standard Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 Switching Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14 Transceiver Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 Core Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 Clock Tree Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 PLL Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20 Embedded Multiplier Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22 Memory Block Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22 Configuration and JTAG Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22 Periphery Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-23 High-Speed I/O Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 External Memory Interface Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-28 Duty Cycle Distortion Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 OCT Calibration Timing Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 IOE Programmable Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 I/O Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-33 Chapter Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-39 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 2 Cyclone IV Device Handbook, Volume 3 Contents © November 2009 Altera Corporation Chapter Revision Dates The chapters in this book, Cyclone IV Device Handbook, Volume 3, were revised on the following dates. Where chapters or groups of chapters are available separately, part numbers are listed. Chapter 1 © November 2009 Cyclone IV Device Datasheet Revised: November 2009 Part Number: CYIV-53001-1.0 Altera Corporation Cyclone IV Device Handbook, Volume 3 iv Cyclone IV Device Handbook, Volume 3 Chapter Revision Dates © November 2009 Altera Corporation Additional Information About this Handbook This handbook provides comprehensive information about the Altera® Cyclone® IV family of devices. How to Contact Altera For the most up-to-date information about Altera products, see the following table. Contact (Note 1) Contact Method Address Technical support Website www.altera.com/support Technical training Website www.altera.com/training Email custrain@altera.com Non-technical support (General) Email nacomp@altera.com (Software Licensing) Email authorization@altera.com Note: (1) You can also contact your local Altera sales office or sales representative. Typographic Conventions The following table shows the typographic conventions that this document uses. Visual Cue Meaning Bold Type with Initial Capital Letters Indicates command names, dialog box titles, dialog box options, and other GUI labels. For example, Save As dialog box. For GUI elements, capitalization matches the GUI. bold type Indicates directory names, project names, disk drive names, file names, file name extensions, dialog box options, software utility names, and other GUI labels. For example, \qdesigns directory, d: drive, and chiptrip.gdf. Italic Type with Initial Capital Letters Indicates document titles. For example, AN 519: Stratix IV Design Guidelines. Italic type Indicates variables. For example, n + 1. Variable names are enclosed in angle brackets (< >). For example, <file name> and <project name>.pof. Initial Capital Letters Indicates keyboard keys and menu names. For example, Delete key and the Options menu. “Subheading Title” Quotation marks indicate references to sections within a document and titles of Quartus II Help topics. For example, “Typographic Conventions.” © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 Info–vi Additional Information Visual Cue Courier type Meaning Indicates signal, port, register, bit, block, and primitive names. For example, data1, tdi, and input. Active-low signals are denoted by suffix n. For example, resetn. Indicates command line commands and anything that must be typed exactly as it appears. For example, c:\qdesigns\tutorial\chiptrip.gdf. Also indicates sections of an actual file, such as a Report File, references to parts of files (for example, the AHDL keyword SUBDESIGN), and logic function names (for example, TRI). 1., 2., 3., and a., b., c., and so on. Numbered steps indicate a list of items when the sequence of the items is important, such as the steps listed in a procedure. ■ ■ Bullets indicate a list of items when the sequence of the items is not important. 1 The hand points to information that requires special attention. c A caution calls attention to a condition or possible situation that can damage or destroy the product or your work. w A warning calls attention to a condition or possible situation that can cause you injury. r The angled arrow instructs you to press Enter. f The feet direct you to more information about a particular topic. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Section 1. Device Datasheet This section provides the Cyclone® IV device datasheet. It includes the following chapter: ■ Chapter 1, Cyclone IV Device Datasheet Revision History Refer to each chapter for its own specific revision history. For information about when each chapter was updated, refer to the Chapter Revision Dates section, which appears in the complete handbook. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1. Cyclone IV Device Datasheet CYIV-53001-1.0 This chapter describes the electrical characteristics for Cyclone® IV devices. 1 References to Cyclone IV devices in this chapter refer only to Cyclone IV GX devices. Information about Cyclone IV E devices will be included in a future revision of this chapter. This chapter includes the following sections: ■ “Operating Conditions” on page 1–1 ■ “Power Consumption” on page 1–14 ■ “Switching Characteristics” on page 1–14 ■ “I/O Timing” on page 1–33 ■ “Glossary” on page 1–33 Operating Conditions When Cyclone IV devices are implemented in a system, they are rated according to a set of defined parameters. To maintain the highest possible performance and reliability of Cyclone IV devices, system designers must consider the operating requirements described in this chapter. Cyclone IV devices are offered in commercial and industrial grades. Commercial devices are offered in –6 (fastest), –7, and –8 speed grades. Industrial devices are offered only in –7 speed grade. 1 In this chapter, a prefix associated with the operating temperature range is attached to the speed grades; commercial with “C” prefix and industrial with “I” prefix. Commercial devices are therefore indicated as C6, C7, and C8 per respective speed grade while industrial devices are indicated as I7. Absolute Maximum Ratings Absolute maximum ratings define the maximum operating conditions for Cyclone IV devices. The values are based on experiments conducted with the device and theoretical modeling of breakdown and damage mechanisms. The functional operation of the device is not implied at these conditions. Table 1–1 lists the absolute maximum ratings for Cyclone IV devices. c © November 2009 Conditions beyond those listed in Table 1–1 cause permanent damage to the device. Additionally, device operation at the absolute maximum ratings for extended periods of time has adverse effects on the device. Altera Corporation Cyclone IV Device Handbook, Volume 3 1–2 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Table 1–1. Cyclone IV Devices Absolute Maximum Ratings (Note 1) —Preliminary Symbol Parameter Min Max Unit VCCINT Core voltage, PCI Express (PCIe) Hard IP block, and transceiver physical coding sublayer (PCS) power supply –0.5 1.8 V VCCA Phase-locked loop (PLL) analog power supply –0.5 3.75 V VCCD_PLL PLL digital power supply –0.5 1.8 V VCCIO I/O banks power supply –0.5 3.9 V VCC_CLKIN Differential clock input pins power supply –0.5 3.9 V VCCH_GXB Transceiver output buffer power supply — 2.625 V VCCA_GXB Transceiver physical medium attachment (PMA) and auxiliary power supply — 2.625 V VCCL_GXB Transceiver PMA and auxiliary power supply –0.5 1.8 V VI DC input voltage –0.5 3.95 V IOUT DC output current, per pin –25 40 mA VESDHBM Electrostatic discharge voltage using the human body model — ±2000 V VESDCDM Electrostatic discharge voltage using the charged device model — ±500 V TSTG Storage temperature –65 150 °C TJ Operating junction temperature –40 100 °C Note to Table 1–1: (1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the power supply. Maximum Allowed Overshoot or Undershoot Voltage During transitions, input signals may overshoot to the voltage shown in Table 1–2 and undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods shorter than 20 ns. Table 1–2 lists the maximum allowed input overshoot voltage and the duration of the overshoot voltage as a percentage over the lifetime of the device. The maximum allowed overshoot duration is specified as percentage of high-time over the lifetime of the device. 1 A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to 4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime of 10 years, this amounts to 10.74/10ths of a year. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–3 Table 1–2. Cyclone IV Devices Maximum Allowed Overshoot During Transitions over a 10-Year Time Frame Symbol Vi Parameter AC Input Voltage Condition Overshoot Duration as % of High Time Unit VI = 3.95 V 100 % VI = 4.0 V 95.67 % VI = 4.05 V 55.24 % VI = 4.10 V 31.97 % VI = 4.15 V 18.52 % VI = 4.20 V 10.74 % VI = 4.25 V 6.23 % VI = 4.30 V 3.62 % VI = 4.35 V 2.1 % VI = 4.40 V 1.22 % VI = 4.45 V 0.71 % VI = 4.50 V 0.41 % VI = 4.60 V 0.14 % VI = 4.70 V 0.047 % Figure 1–1 shows the methodology to determine the overshoot duration. The overshoot voltage is shown in red and is present on the input pin of the Cyclone IV device at over 4.1 V but below 4.2 V. From Table 1–2, for an overshoot of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over a 10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period assumes that the device is always turned on with 100% I/O toggle rate and 50% duty cycle signal. For lower I/O toggle rates and situations in which the device is in an idle state, lifetimes are increased. Figure 1–1. Cyclone IV Devices Overshoot Duration 4.2 V 4.1 V 3.3 V ΔT T © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–4 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Recommended Operating Conditions This section lists the functional operation limits for AC and DC parameters for Cyclone IV devices. The steady-state voltage and current values expected from Cyclone IV devices are provided in Table 1–3. All supplies must be strictly monotonic without plateaus. Table 1–3. Cyclone IV Devices Recommended Operating Conditions (Part 1 of 2)—Preliminary Symbol Parameter Conditions Min Typ Max Unit VCCINT (3) Core voltage, PCIe Hard IP block, and transceiver PCS power supply — 1.16 1.2 1.24 V VCCA (1),(3) PLL analog power supply — 2.375 2.5 2.625 V VCCD_PLL (2) PLL digital power supply — 1.16 1.2 1.24 V I/O banks power supply for 3.3-V operation — 3.135 3.3 3.465 V I/O banks power supply for 3.0-V operation — 2.85 3 3.15 V I/O banks power supply for 2.5-V operation — 2.375 2.5 2.625 V I/O banks power supply for 1.8-V operation — 1.71 1.8 1.89 V I/O banks power supply for 1.5-V operation — 1.425 1.5 1.575 V I/O banks power supply for 1.2-V operation — 1.14 1.2 1.26 V Differential clock input pins power supply for 3.3-V operation — 3.135 3.3 3.465 V Differential clock input pins power supply for 3.0-V operation — 2.85 3 3.15 V Differential clock input pins power supply for 2.5-V operation — 2.375 2.5 2.625 V Differential clock input pins power supply for 1.8-V operation — 1.71 1.8 1.89 V Differential clock input pins power supply for 1.5-V operation — 1.425 1.5 1.575 V Differential clock input pins power supply for 1.2-V operation — 1.14 1.2 1.26 V VCCH_GXB Transceiver output buffer power supply — 2.375 2.5 2.625 V VCCA_GXB Transceiver PMA and auxiliary power supply — 2.375 2.5 2.625 V VCCL_GXB Transceiver PMA and auxiliary power supply — 1.16 1.2 1.24 V VI DC input voltage — –0.5 — 3.6 V VO DC output voltage — 0 — VCC IO V TJ Operating junction temperature For commercial use 0 — 85 °C For industrial use –40 — 100 °C VCCIO (3), (4) VCC_CLKIN (3),(5) Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–5 Table 1–3. Cyclone IV Devices Recommended Operating Conditions (Part 2 of 2)—Preliminary Symbol tRAM P Parameter Power supply ramp time Conditions Min Typ Max Unit Standard power-on reset (POR) (6) 50 µs — 50 ms — Fast POR (7) 50 µs — 3 ms — — — — 10 mA Magnitude of DC current across PCI-clamp diode when enabled IDiode Notes to Table 1–3: (1) (2) (3) (4) All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and must be powered up and powered down at the same time. VCC D_P LL must always be connected to VCCINT through a decoupling capacitor and ferrite bead. Power supplies must rise monotonically. VCC IO for all I/O banks must be powered up during device operation. Configurations pins are powered up by VC CIO of I/O Banks 3, 8, and 9 where I/O Banks 3 and 9 only support VC CIO of 1.5 V, 1.8 V, 2.5 V, 3.0 V and 3.3 V. For fast passive parallel (FPP) configuration mode, the VC CIO level of I/O Bank 8 must be powered up to 1.5 V, 1.8 V, 2.5 V, 3.0 V, and 3.3 V. (5) VCC_CLKIN must be set to 2.5 V if the CLKIN is used as high-speed serial interface (HSSI) refclk. VCC_CLKIN located at I/O Banks 3B and 8B only support a nominal voltage level of 2.5 V for LVDS input function because they are dedicated for HSSI refclk. (6) POR time for Standard POR ranges between 50–200 ms. VCCINT, VCCA, and VCCIO of I/O Banks 3, 8, and 9 should reach the recommended operating range within 50 ms. (7) POR time for Fast POR ranges between 3–9 ms. VCCINT, VCCA , and VCCIO of I/O Banks 3, 8, and 9 should reach the recommended operating range within 3 ms. DC Characteristics This section lists the I/O leakage current, pin capacitance, on-chip termination (OCT) tolerance, and bus hold specifications for Cyclone IV devices. Supply Current The device supply current requirement is the minimum current drawn from the power supply pins that can be used as a reference for power size planning. Use the Excel-based early power estimator (EPE) to get the supply current estimates for your design because these currents vary greatly with the resources used. Table 1–4 lists I/O pin leakage current for Cyclone IV devices. Table 1–4. Cyclone IV Devices I/O Pin Leakage Current (Note 1) , (2) Symbol Parameter Conditions Device Min Typ Max Unit II Input pin leakage current VI = 0 V to VCCIOMAX — –10 — 10 μA IOZ Tristated I/O pin leakage current VO = 0 V to VCCIOMAX — –10 — 10 μA Notes to Table 1–4: (1) This value is specified for normal device operation. The value varies during device power-up. This applies for all VCC IO settings (3.3, 3.0, 2.5, 1.8, 1.5, and 1.2 V). (2) 10 μA I/O leakage current limit is applicable when the internal clamping diode is off. A higher current can be observed when the diode is on. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–6 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Bus Hold Bus hold retains the last valid logic state after the source driving it either enters the high impedance state or is removed. Each I/O pin has an option to enable bus hold in user mode. Bus hold is always disabled in configuration mode. Table 1–5 lists bus hold specifications for Cyclone IV devices. Table 1–5. Cyclone IV Devices Bus Hold Parameter (Note 1)—Preliminary VCC IO (V) Parameter Condition 1.2 1.5 1.8 2.5 3.0 3.3 Unit Min Max Min Max Min Max Min Max Min Max Min Max Bus hold low, sustaining current VIN > VIL (maximum) 8 — 12 — 30 — 50 — 70 — 70 — μA Bus hold high, sustaining current VIN < VIL (minimum) –8 — –12 — –30 — –50 — –70 — –70 — μA Bus hold low, overdrive current 0 V < VIN < VCC IO — 125 — 175 — 200 — 300 — 500 — 500 μA Bus hold high, overdrive current 0 V < VIN < VCC IO — –125 — –175 — –200 — –300 — –500 — –500 μA — 0.3 0.9 0.68 1.07 0.7 1.7 0.8 2 0.8 2 V Bus hold trip point 0.375 1.125 Note to Table 1–5: (1) The bus hold trip points are based on calculated input voltages from the JEDEC standard. OCT Specifications Table 1–6 lists the variation of OCT without calibration across process, temperature, and voltage. Table 1–6. Cyclone IV Devices Series OCT without Calibration Specifications —Preliminary Resistance Tolerance Description Series OCT without calibration VCCIO (V) Unit Commercial Max Industrial Max 3.0 ±30 ±40 % 2.5 ±30 ±40 % 1.8 +40 ±50 % 1.5 +50 ±50 % 1.2 +50 ±50 % OCT calibration is automatically performed at device power-up for OCT enabled I/Os. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–7 Table 1–7 lists the OCT calibration accuracy at device power-up. Table 1–7. Cyclone IV Devices Series OCT with Calibration at Device Power-Up Specifications —Preliminary Calibration Accuracy Description Series OCT with calibration at device power-up VCCIO (V) Industrial and Automotive Max Unit Commercial Max 3.0 ±10 ±10 % 2.5 ±10 ±10 % 1.8 ±10 ±10 % 1.5 ±10 ±10 % 1.2 ±10 ±10 % The OCT resistance may vary with the variation of temperature and voltage after calibration at device power-up. Use Table 1–8 and Equation 1–1 to determine the final OCT resistance considering the variations after calibration at device power-up. Table 1–8 lists the change percentage of the OCT resistance with voltage and temperature. Table 1–8. Cyclone IV Devices OCT Variation After Calibration at Device Power-Up —Preliminary © November 2009 Nominal Voltage dR/dT (%/°C) dR/dV (%/mV) 3.0 0.262 –0.026 2.5 0.234 –0.039 1.8 0.219 –0.086 1.5 0.199 –0.136 1.2 0.161 –0.288 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–8 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Equation 1–1. Final OCT Resistance (Note 1), (2), (3), (4), (5), (6) ΔRV = (V2 – V1) × 1000 × dR/dV ––––– (7) ΔRT = (T2 – T1) × dR/dT ––––– (8) For ΔRx < 0; MFx = 1/ (|ΔRx|/100 + 1) ––––– (9) For ΔRx > 0; MFx = ΔRx /100 + 1 ––––– (10) MF = MFV × MFT ––––– (11) Rfinal = Rinitia l × MF ––––– (12) Notes to Equation 1–1: (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) T2 is the final temperature. T1 is the initial temperature. MF is multiplication factor. Rfinal is final resistance. Rinitial is initial resistance. Subscript x refers to both V and T. ΔRV is variation of resistance with voltage. ΔRT is variation of resistance with temperature. dR/dT is the change percentage of resistance with temperature after calibration at device power-up. dR/dV is the change percentage of resistance with voltage after calibration at device power-up. V2 is final voltage. V1 is the initial voltage. Example 1–1 shows how to calculate the change of 50 Ω I/O impedance from 25°C at 3.0 V to 85°C at 3.15 V: Example 1–1. Impedance Change ΔRV = (3.15 – 3) × 1000 × –0.026 = –3.83 ΔRT = (85 – 25) × 0.262 = 15.72 Because ΔRV is negative, MF V = 1 / (3.83/100 + 1) = 0.963 Because ΔRT is positive, MFT = 15.72/100 + 1 = 1.157 MF = 0.963 × 1.157 = 1.114 Rfinal = 50 × 1.114 = 55.71 Ω Pin Capacitance Table 1–9 lists the pin capacitance for Cyclone IV devices. Table 1–9. Cyclone IV Devices Pin Capacitance (Part 1 of 2)—Preliminary Symbol Parameter Typical – Quad Flat Pack (QFP) Typical – Quad Flat No Leads (QFN) Typical – Fineline BGA (FBGA) Unit CIOTB Input capacitance on top and bottom I/O pins 7 7 6 pF CIOLR Input capacitance on right I/O pins 7 7 5 pF CLV DSLR Input capacitance on right I/O pins with dedicated LVDS output 8 8 7 pF Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–9 Table 1–9. Cyclone IV Devices Pin Capacitance (Part 2 of 2)—Preliminary Typical – Quad Flat No Leads (QFN) Typical – Fineline BGA (FBGA) Unit Symbol Parameter Typical – Quad Flat Pack (QFP) CV REFLR (1) Input capacitance on right dual-purpose VREF pin when used as VREF or user I/O pin 21 21 21 pF CV REFTB (1) Input capacitance on top and bottom dual-purpose VREF pin when used as VREF or user I/O pin 23 23 23 pF CC LKTB Input capacitance on top and bottom dedicated clock input pins 7 7 6 pF CC LKLR Input capacitance on right dedicated clock input pins 6 6 5 pF Note to Table 1–9: (1) When VREF pin is used as regular input or output, a reduced performance of toggle rate and t CO is expected due to higher pin capacitance. Internal Weak Pull-Up and Weak Pull-Down Resistor Table 1–10 lists the weak pull-up and pull-down resistor values for Cyclone IV devices. Table 1–10. Cyclone IV Devices Internal Weak Pull-Up and Weak Pull-Down Resistor (Note 1) —Preliminary Symbol R_P U R_P D Parameter Value of I/O pin pull-up resistor before and during configuration, as well as user mode if the programmable pull-up resistor option is enabled Value of I/O pin pull-down resistor before and during configuration Conditions Min Typ Max Unit VCC IO = 3.3 V ± 5% (2), (3) 7 25 41 kΩ VCC IO = 3.0 V ± 5% (2), (3) 7 28 47 kΩ VCC IO = 2.5 V ± 5% (2), (3) 8 35 61 kΩ VCC IO = 1.8 V ± 5% (2), (3) 10 57 108 kΩ VCC IO = 1.5 V ± 5% (2), (3) 13 82 163 kΩ VCC IO = 1.2 V ± 5% (2), (3) 19 143 351 kΩ VCC IO = 3.3 V ± 5% (4) 6 19 30 kΩ VCC IO = 3.0 V ± 5% (4) 6 22 36 kΩ VCC IO = 2.5 V ± 5% (4) 6 25 43 kΩ VCC IO = 1.8 V ± 5% (4) 7 35 71 kΩ VCC IO = 1.5 V ± 5% (4) 8 50 112 kΩ Notes to Table 1–10: (1) All I/O pins have an option to enable weak pull -up except configuration, test, and JTAG pin. Weak pull-down feature is only available for JTAG TCK. (2) Pin pull -up resistance values may be lower if an external source drives the pin higher than VCC IO . (3) R_P U = (VCCIO – VI )/I R_PU Minimum condition: –40°C; VCC IO = VC C + 5%, VI = VCC + 5% – 50 mV; Typical condition: 25°C; VCC IO = VC C, VI = 0 V; Maximum condition: 100°C; VCCIO = VCC – 5% , VI = 0 V; in which VI refers to the input voltage at the I/O pin. (4) R_P D = VI /I R_PD Minimum condition: –40°C; VCC IO = VC C + 5%, VI = 50 mV; Typical condition: 25°C; VCC IO = VC C, VI = VCC – 5% ; Maximum condition: 100°C; VCCIO = VCC – 5% , VI = VC C – 5% ; in which VI refers to the input voltage at the I/O pin. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–10 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Hot-Socketing Table 1–11 lists the hot-socketing specifications for Cyclone IV devices. Table 1–11. Cyclone IV Devices Hot -Socketing Specifications —Preliminary Symbol Parameter Maximum IIOPIN(DC ) DC current per I/O pin 300 μA IIOPIN(A C) AC current per I/O pin 8 mA (1) IXC VRTX (DC) DC current per transceiver TX pin — IXC VRRX (DC ) DC current per transceiver RX pin — Note to Table 1–11: (1) The I/O ramp rate is 10 ns or more. For ramp rates faster than 10 ns, |IIOPIN| = C dv/dt, in which C is the I/O pin capacitance and dv/dt is the slew rate. 1 During hot-socketing, the I/O pin capacitance is less than 15 pF and the clock pin capacitance is less than 20 pF. Schmitt Trigger Input Cyclone IV devices support Schmitt trigger input on the TDI, TMS, TCK, nSTATUS, nCONFIG, nCE, CONF_DONE, and DCLK pins. A Schmitt trigger feature introduces hysteresis to the input signal for improved noise immunity, especially for signals with slow edge rate. Table 1–12 lists the hysteresis specifications across the supported V CCIO range for Schmitt trigger inputs in Cyclone IV devices. Table 1–12. Hysteresis Specifications for Schmitt Trigger Input in Cyclone IV Devices —Preliminary Symbol VS CHM ITT Parameter Hysteresis for Schmitt trigger input Conditions Minimum Typical Maximum Unit VCC IO = 3.3 V 200 — — mV VCC IO = 2.5 V 200 — — mV VCC IO = 1.8 V 140 — — mV VCC IO = 1.5 V 110 — — mV I/O Standard Specifications The following tables list input voltage sensitivities (V IH and VIL), output voltage (VOH and VOL), and current drive characteristics (IOH and IOL) for various I/O standards supported by Cyclone IV devices. Table 1–13 through Table 1–18 provide the I/O standard specifications for Cyclone IV devices. Table 1–13. Cyclone IV Devices Single -Ended I/O Standard Specifications VCC IO (V) VIL (V) (Note 1), (2) (Part 1 of 2)—Preliminary VIH (V) VOL (V) VO H (V) IO H (mA) Min Typ Max Min Max Min Max Max Min IO L (mA) 3.135 3.3 3.465 — 0.8 1.7 3.6 0.45 2.4 4 –4 3.3-V LVCMOS (3) 3.135 3.3 3.465 — 0.8 1.7 3.6 0.2 VC CIO – 0.2 2 –2 I/O Standard 3.3-V LVTTL (3) 3.0-V LVTTL (3) 2.85 3.0 3.15 –0.3 0.8 1.7 VC CIO + 0.3 0.45 2.4 4 –4 3.0-V LVCMOS (3) 2.85 3.0 3.15 –0.3 0.8 1.7 VC CIO + 0.3 0.2 VC CIO – 0.2 0.1 –0.1 2.5-V LVTTL and LVCMOS (3) 2.375 2.5 2.625 –0.3 0.7 1.7 VC CIO + 0.3 0.4 2.0 1 –1 Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–11 Table 1–13. Cyclone IV Devices Single -Ended I/O Standard Specifications VCC IO (V) VIL (V) (Note 1), (2) (Part 2 of 2)—Preliminary VIH (V) VOL (V) VO H (V) IO H (mA) Min Typ Max Min Max Min Max Max Min IO L (mA) 1.8-V LVTTL and LVCMOS 1.71 1.8 1.89 –0.3 0.35 * VCCIO 0.65 * VCC IO 2.25 0.45 VCC IO – 0.45 2 –2 1.5-V LVCMOS 1.425 1.5 1.575 –0.3 0.35 * VCCIO 0.65 * VCC IO VC CIO + 0.3 0.25 * VC CIO 0.75 * VCC IO 2 –2 1.2-V LVCMOS 1.14 1.2 1.26 –0.3 0.35 * VCCIO 0.65 * VCC IO VC CIO + 0.3 0.25 * VC CIO 0.75 * VCC IO 2 –2 3.0-V PCI 2.85 3.0 3.15 — 0.3 * VCCIO 0.5 * VCC IO VC CIO + 0.3 0.1 * VCC IO 0.9 * VC CIO 1.5 –0.5 3.0-V PCI-X 2.85 3.0 3.15 — 0.35* VCCIO 0.5 * VCC IO VC CIO + 0.3 0.1 * VCC IO 0.9 * VC CIO 1.5 –0.5 I/O Standard Notes to Table 1–13: (1) For voltage -referenced receiver input waveform and explanation of terms used in Table 1–13, refer to “Single-ended voltage-referenced I/O Standard” in“Glossary” on page 1–33. (2) AC load CL = 10 pF (3) For more detail about interfacing Cyclone IV devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O standards, refer to AN 447: Interfacing Cyclone III and Cyclone IV Devices with 3.3/3.0/2.5-V LVTTL/LVCMOS I/O Systems. Table 1–14. Cyclone IV Devices Single -Ended SSTL and HSTL I/O Reference Voltage Specifications (Note 1)—Preliminary VCC IO (V) I/O Standard VREF (V) VTT (V) (Note 2) Min Typ Max Min Typ Max Min Typ Max SSTL-2 Class I, II 2.375 2.5 2.625 1.19 1.25 1.31 VREF – 0.04 VREF VREF + 0.04 SSTL-18 Class I, II 1.7 1.8 1.9 0.833 0.9 0.969 VREF – 0.04 VREF VREF + 0.04 HSTL-18 Class I, II 1.71 1.8 1.89 0.85 0.9 0.95 0.85 0.9 0.95 HSTL-15 Class I, II 1.425 1.5 1.575 0.71 0.75 0.79 0.71 0.75 0.79 HSTL-12 Class I, II 1.14 1.2 1.26 — 0.5 * VCC IO — 0.48 * VCC IO (3) 0.5 * VC CIO (3) 0.52 * VCC IO (3) 0.47 * VCC IO (4) 0.5 * VC CIO (4) 0.53 * VCC IO (4) Notes to Table 1–14: (1) (2) (3) (4) For an explanation of terms used in Table 1–14, refer to “Glossary” on page 1–33. VTT of transmitting device must track VREF of the receiving device. Value shown refers to DC input reference voltage, VREF( DC) . Value shown refers to AC input reference voltage, VREF( AC ). © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–12 Chapter 1: Cyclone IV Device Datasheet Operating Conditions Table 1–15. Cyclone IV Devices Single -Ended SSTL and HSTL I/O Standards Signal Specifications —Preliminary I/O Standard VIL(DC) (V) VIH(DC ) (V) VIL(AC ) (V) VIH (A C) (V) VOL (V) VOH (V) IOL (mA) IOH (mA) Min Max Min Max Min Max Min Max Max Min SSTL-2 Class I — VREF – 0.18 VREF + 0.18 — — VREF – 0.35 VREF + 0.35 — VTT – 0.57 VTT + 0.57 8.1 –8.1 SSTL-2 Class II — VREF – 0.18 VREF + 0.18 — — VREF – 0.35 VREF + 0.35 — VTT – 0.76 VTT + 0.76 16.4 –16.4 SSTL-18 Class I — VREF – 0.125 VREF + 0.125 — — VREF – 0.25 VREF + 0.25 — VTT – 0.475 VTT + 0.475 6.7 –6.7 SSTL-18 Class II — VREF – 0.125 VREF + 0.125 — — VREF – 0.25 VREF + 0.25 — 0.28 VC CIO – 0.28 13.4 –13.4 HSTL-18 Class I — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VCC IO – 0.4 8 –8 HSTL-18 Class II — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VC CIO – 0.4 16 –16 HSTL-15 Class I — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VC CIO – 0.4 8 –8 HSTL-15 Class II — VREF – 0.1 VREF + 0.1 — — VREF – 0.2 VREF + 0.2 — 0.4 VC CIO – 0.4 16 –16 HSTL-12 Class I –0.15 VREF – 0.08 VREF + 0.08 VCC IO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VC CIO + 0.24 0.25 × VCC IO 0.75 × VC CIO 8 –8 HSTL-12 Class II –0.15 VREF – 0.08 VREF + 0.08 VCC IO + 0.15 –0.24 VREF – 0.15 VREF + 0.15 VC CIO + 0.24 0.25 × VCC IO 0.75 × VC CIO 14 –14 f For more illustrations of receiver input and transmitter output waveforms, and for other differential I/O standards, refer to the I/O Features in Cyclone IV Devices chapter in volume 1. Table 1–16. Cyclone IV Devices Differential SSTL I/O Standard Specifications —Preliminary VC CIO (V) VSwing(D C) (V) VX (A C) (V) VSw ing(AC ) (V) VOX (AC) (V) I/O Standard Min Typ Max Min Max Min Typ Max SSTL-2 Class I, II 2.375 2.5 2.625 0.36 VCC IO VCC IO /2 – 0.2 — VC CIO/2 + 0.2 0.7 SSTL-18 Class I, II 1.7 1.8 1.90 VCC IO VCC IO/2 – 0.175 — VC CIO/2 + 0.175 0.5 0.25 Table 1–17. Cyclone IV Devices Differential HSTL I/O Standard Specifications VCC IO (V) VDIF(DC) (V) Min Max Min Typ Max VCC IO VC CIO/2 – 0.125 — VCC IO /2 + 0.125 VCC IO VC CIO/2 – 0.125 — VCC IO /2 + 0.125 (Part 1 of 2) —Preliminary VX(A C) (V) VCM (D C) (V) VD IF(A C) (V) I/O Standard HSTL-18 Class I, II Min Typ Max Min Max Min Typ Max Min Typ Max Mi n Max 1.71 1.8 1.89 0.2 — 0.85 — 0.95 0.85 — 0.95 0.4 — Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Operating Conditions 1–13 Table 1–17. Cyclone IV Devices Differential HSTL I/O Standard Specifications VCC IO (V) VDIF(DC) (V) (Part 2 of 2) —Preliminary VX(A C) (V) VCM (D C) (V) VD IF(A C) (V) I/O Standard Min Typ Max Min Max Min Typ Max Min Typ Max Mi n Max HSTL-15 Class I, II 1.425 1.5 1.575 0.2 — 0.71 — 0.79 0.71 — 0.79 0.4 — HSTL-12 Class I, II 1.14 1.2 1.26 0.16 VC CIO 0.48 * VCC IO — 0.52 * VCC IO 0.48 * VC CIO — 0.52 * VCCIO 0.3 0.48 * VCCIO Table 1–18. Cyclone IV Devices Differential I/O Standard Specifications (Note 1) (Part 1 of 2)—Preliminary VC CIO (V) I/O Standard LVPECL (Row I/Os) (4) LVPECL (Column I/Os) (4) LVDS (Row I/Os) LVDS (Column I/Os) Min 2.375 2.375 2.375 2.375 Typ 2.5 2.5 2.5 2.5 VID (mV) Max Min 2.625 100 2.625 100 2.625 100 2.625 100 Max — — — — VIcM (V) (2) Min Condition VO D (mV) (3) Max Min Typ 0.05 DM AX ≤ 500 Mbps 1.80 0.55 500 Mbps ≤ DM AX ≤ 700 Mbps 1.80 1.05 DM AX > 700 Mbps 1.55 0.05 DM AX ≤ 500 Mbps 1.80 0.55 500 Mbps ≤DM AX ≤ 700 Mbps 1.80 1.05 DM AX > 700 Mbps 1.55 0.05 VO S (V) (3) Max Min Typ Max — — — — — — — — — — — — DM AX ≤ 500 Mbps 1.80 0.55 500 Mbps ≤DM AX ≤ 700 Mbps 1.80 247 — 600 1.125 1.25 1.375 1.05 DM AX > 700 Mbps 1.55 0.05 DM AX ≤ 500 Mbps 1.80 0.55 500 Mbps ≤DM AX ≤ 700 Mbps 1.80 247 — 600 1.125 1.25 1.375 1.05 DM AX > 700 Mbps 1.55 BLVDS (Row I/Os) (5) 2.375 2.5 2.625 100 — — — — — — — — — — BLVDS (Column I/Os) (5) 2.375 2.5 2.625 100 — — — — — — — — — — mini -LVDS (Row I/Os) (6) 2.375 2.5 2.625 — — — — — 300 — 600 1.0 1.2 1.4 mini -LVDS (Column I/Os) (6) 2.375 2.5 2.625 — — — — — 300 — 600 1.0 1.2 1.4 RSDS® (Row I/Os)(6) 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.5 RSDS (Column I/Os) (6) 2.375 2.5 2.625 — — — — — 100 200 600 0.5 1.2 1.5 © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–14 Chapter 1: Cyclone IV Device Datasheet Power Consumption Table 1–18. Cyclone IV Devices Differential I/O Standard Specifications (Note 1) (Part 2 of 2)—Preliminary I/O Standard VC CIO (V) VID (mV) VIcM (V) (2) VO D (mV) (3) Min Typ Max Min Max Min Condition Max Min Typ PPDS (Row I/Os) (6) 2.375 2.5 2.625 — — — — — PPDS (Column I/Os) (6) 2.375 2.5 2.625 — — — — — VO S (V) (3) Max Min Typ Max 100 200 600 0.5 1.2 1.4 100 200 600 0.5 1.2 1.4 ® Notes to Table 1–18: (1) (2) (3) (4) (5) (6) For an explanation of terms used in Table 1–18, refer to “Transmitter Output Waveform” in “Glossary” on page 1–33. VIN range: 0 V ≤VIN ≤1.85 V. RL range: 90 ≤ RL ≤ 110 Ω. LVPECL input standard is only supported at clock input. Output standard is not supported. No fixed VIN , VOD , and VOS specifications for BLVDS. They are dependent on the system topology. Mini -LVDS, RSDS, and PPDS standards are only supported at the output pins for Cyclone IV devices. Power Consumption You can use the following methods to estimate power for a design: ■ the Excel-based EPE ■ the Quartus® II PowerPlay power analyzer feature The interactive Excel-based EPE is used prior to designing the device to get a magnitude estimate of the device power. The Quartus II PowerPlay power analyzer provides better quality estimates based on the specifics of the design after place-and-route is complete. The PowerPlay power analyzer can apply a combination of user-entered, simulation-derived, and estimated signal activities that, combined with detailed circuit models, can yield very accurate power estimates. f For more information about power estimation tools, refer to the Early Power Estimator User Guide and the PowerPlay Power Analysis chapter in volume 3 of the Quartus II Handbook. Switching Characteristics This section provides performance characteristics of Cyclone IV core and periphery blocks for commercial grade devices. These characteristics can be designated as Preliminary or Final. ■ Preliminary characteristics are created using simulation results, process data, and other known parameters. The upper-right hand corner of these tables show the designation as “Preliminary”. ■ Final numbers are based on actual silicon characterization and testing. The numbers reflect the actual performance of the device under worst-case silicon process, voltage, and junction temperature conditions. There are no designations on finalized tables. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–15 Transceiver Performance Specifications Table 1–19 lists the Cyclone IV GX transceiver specifications. Table 1–19. Cyclone IV GX Transceiver Specification (Part 1 of 3)—Preliminary C6 Symbol/ Description C7 C8 Conditions Unit Min Typ Max Min Typ Max Min Typ Max 50 — 156.25 50 — 156.25 50 — 156.25 MHz — 33 30 — 33 30 — 33 kHz — — — — Reference Clock Input frequency from REFCLK input pins — Spread-spectrum modulating clock frequency PCI Express 30 Spread-spectrum downspread PCI Express — 0 to –0.5% 0 to –0.5% 0 to –0.5% — — 2000 ± 1% — — 2000 ± 1% — — 2000 ± 1% — Ω 10 — 125 10 — 125 10 — 125 MHz — 125 — — 125 — — 125 — MHz — — 1 — — 1 — — 1 — µs Data rate — 600 — 3125 600 — 3125 600 — 2500 Mbps Absolute VM AX for a receiver pin (1) — — — 1.5 — — 1.5 — — 1.5 V Absolute VM IN for a receiver pin — –0.4 — — –0.4 — — –0.4 — — V — Rref — Transceiver Clocks Calibration block clock frequency — fixedclk clock frequency Transceiver block minimum power-down pulse width PCI Express Receiver Detect Receiver Maximum peak-to-peak differential input voltage VID (diff p-p) VIC M = 0.82 V setting — — 2.7 — — 2.7 — — 2.7 V Minimum peak-to-peak differential input voltage VID (diff p-p) Data Rate = 600 Mbps to 3.125 Gbps. 100 — — 100 — — 100 — — mV VICM VIC M = 0.82 V setting — 820 — — 820 — — 820 — mV 100−Ω setting — 100 — — 100 — — 100 — Ω 150−Ω setting — 150 — — 150 — — 150 — Ω Differential on-chip termination resistors © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–16 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Table 1–19. Cyclone IV GX Transceiver Specification (Part 2 of 3)—Preliminary Symbol/ Description C6 C7 C8 Conditions Unit Min Typ Max Min Typ Max Min Return loss differential mode PCI Express 50 MHz to 1.25 GHz: –10dB Return loss common mode PCI Express 50 MHz to 1.25 GHz: –6dB Typ Max ± 62.5, 100, 125, 200, Programmable PPM detector (2) — Run length — — 80 — — 80 — — 80 — UI Programmable equalization — — — 7 — — 7 — — 7 dB 65 — 175 65 — 175 65 — 175 mV 75 — — 75 — — 75 µs 15 — — 15 — — µs Signal detect/loss threshold PCI Express (PIPE) Mode ppm 250, 300, 500, 1000 CDR LTR time (3) — — — CDR minimum T1b (4) — 15 — LTD lock time (5) — 0 100 4000 0 100 4000 0 100 4000 ns Data lock time from rx_freqlocked (6) — — — 4000 — — 4000 — — 4000 ns DC Gain Setting = 0 — 0 — — 0 — — 0 — dB DC Gain Setting = 1 — 3 — — 3 — — 3 — dB DC Gain Setting = 2 — 6 — — 6 — — 6 — dB 600 — 3125 600 — 3125 600 — 2500 Mbps Programmable DC gain Transmitter Data rate VOC M 0.65 V setting — 650 — — 650 — — 650 — mV Differential on-chip termination resistors 100−Ω setting — 100 — — 100 — — 100 — Ω 150−Ω setting — 150 — — 150 — — 150 — Ω Return loss differential mode PCI Express 50 MHz to 1.25 GHz: –10dB Return loss common mode PCI Express 50 MHz to 1.25 GHz: –6dB Rise time — 50 — 200 50 — 200 50 — 200 ps Fall time — 50 — 200 50 — 200 50 — 200 ps Intra-differential pair skew — — — 15 — — 15 — — 15 ps — — 120 — — 120 — — 120 ps 25 — 156.25 25 — 156.25 25 — 125 MHz Intra-transceiver block skew PCI Express (PIPE) ×4 PLD-Transceiver Interface Interface speed — Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–17 Table 1–19. Cyclone IV GX Transceiver Specification (Part 3 of 3)—Preliminary C6 Symbol/ Description C7 C8 Conditions Unit Min Digital reset pulse width Typ — Max Min Typ Max Min Typ Max Minimum is 2 parallel clock cycles Notes to Table 1–19: (1) (2) (3) (4) The device cannot tolerate prolonged operation at this absolute maximum. The rate matcher supports only up to ±300 parts per million (ppm). Time taken to rx_pll_locked goes high from rx_analogreset deassertion. Refer to Figure 1–2. Time for which the CDR must be kept in lock-to-reference mode after rx_pll_locked goes high and before rx_locktodata is asserted in manual mode. Refer to Figure 1–2. (5) Time taken to recover valid data after the rx_locktodata signal is asserted in manual mode. Refer to Figure 1–2. (6) Time taken to recover valid data after the rx_freqlocked signal goes high in automatic mode. Refer to Figure 1–3. Figure 1–2 shows the lock time parameters in manual mode. 1 LTD = lock-to-data. LTR = lock-to-reference. Figure 1–2. Lock Time Parameters for Manual Mode pll_locked r x_analogreset CDR status LTD r x_locktodata r x_dataout Valid data LTD lock time CDR Minimum T1b © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–18 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Figure 1–3 shows the lock time parameters in automatic mode. Figure 1–3. Lock Time Parameters for Automatic Mode LTR CDR status LTD r x_freqlocked Invalid r x_dataout Valid data data Data lock time from rx_freqlocked Figure 1–4 shows the differential receiver input waveform. Figure 1–4. Receiver Input Waveform Single-Ended Waveform Positive Channel (p) VID Negative Channel (n) VCM Ground Differential Waveform VID (diff peak-peak) = 2 x VID (single-ended) VID p−n=0V VID Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–19 Figure 1–5 shows the transmitter output waveform. Figure 1–5. Transmitter Output Waveform—Preliminary Single-Ended Waveform Positive Channel (p) VOD Negative Channel (n) VCM Ground Differential Waveform VOD (diff peak-peak) = 2 x VOD (single-ended) VOD p−n=0V VOD Table 1–20 lists the typical VOD for TX term that equals 100 Ω. Table 1–20. Typical VOD Setting, TX Term = 100 Ω —Preliminary VOD Setting (mV) Symbol VOD Typical (mV) 400 600 800 900(1) 1000 400 600 800 900 1000 Note to Table 1–20: (1) This setting requires PCIE-1 compliance. Table 1–21 lists the Cyclone IV GX transceiver block AC specifications. Table 1–21. Cyclone IV GX Transceiver Block AC Specification (Note 1) , (2) (Part 1 of 2)—Preliminary C6 Symbol/ Description C7 C8 Conditions Unit Min Typ Max Min Typ Max Min Typ Max — — 0.25 — — 0.25 — — 0.25 PCI Express Transmit Jitter Generation (3) Total jitter at 2.5 Gbps (Gen1) Compliance pattern UI PCI Express Receiver Jitter Tolerance (3) Total jitter at 2.5 Gbps (Gen1) Compliance pattern > 0.6 > 0.6 > 0.6 UI GIGE Transmit Jitter Generation (4) Deterministic jitter (peak-to-peak) Total jitter (peak-to-peak) Pattern = CRPAT — — 0.14 — — 0.14 — — 0.14 UI Pattern = CRPAT — — 0.279 — — 0.279 — — 0.279 UI GIGE Receiver Jitter Tolerance (4) Deterministic jitter tolerance (peak-to-peak) © November 2009 Pattern = CJPAT Altera Corporation > 0.4 > 0.4 > 0.4 UI Cyclone IV Device Handbook, Volume 3 1–20 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Table 1–21. Cyclone IV GX Transceiver Block AC Specification (Note 1) , (2) (Part 2 of 2)—Preliminary C6 Symbol/ Description C7 C8 Conditions Unit Min Combined deterministic and random jitter tolerance (peak-to-peak) Pattern = CJPAT Typ Max Min > 0.66 Typ Max Min > 0.66 Typ Max > 0.66 UI Notes to Table 1–21: (1) (2) (3) (4) Dedicated refclk pins were used to drive the input reference clocks. The Jitter numbers specified are valid for the stated conditions only. The jitter numbers for PCI Express (PIPE) are compliant to the PCIe Base Specification 2.0. The jitter numbers for GIGE are compliant to the IEEE802.3-2002 Specification. Core Performance Specifications Clock Tree Specifications Table 1–22 lists the clock tree specifications for Cyclone IV devices. Table 1–22. Cyclone IV Devices Clock Tree Performance —Preliminary Performance Device Unit C6 C7 C8 EP4CGX15 500 437.5 402 MHz EP4CGX22 500 437.5 402 MHz EP4CGX30 500 437.5 402 MHz EP4CGX50 500 437.5 402 MHz EP4CGX75 500 437.5 402 MHz EP4CGX110 500 437.5 402 MHz EP4CGX150 500 437.5 402 MHz PLL Specifications Table 1–23 describes the PLL specifications for Cyclone IV devices when operating in the commercial junction temperature range (0°C to 85°C), the industrial junction temperature range (–40°C to 100°C), and the automotive junction temperature range (–40°C to 125°C). For more information about the PLL block, refer to “PLL Block” in “Glossary” on page 1–33. Table 1–23. Cyclone IV PLL Specifications (Note 1) (Part 1 of 2)—Preliminary Symbol Parameter Min Typ Max Unit fIN (2) Input clock frequency 5 — 472.5 MHz fINPF D PFD input frequency 5 — 325 MHz fVC O (3) PLL internal VCO operating range 600 — 1300 MHz fINDUTY Input clock duty cycle 40 — 60 % tINJITTER_C CJ (4) Input clock cycle-to-cycle jitter FREF ≥ 100 MHz — — 0.15 UI FREF < 100 MHz — — ±750 ps Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–21 Table 1–23. Cyclone IV PLL Specifications (Note 1) (Part 2 of 2)—Preliminary Symbol Min Typ Max Unit PLL output frequency — — 472.5 MHz PLL output frequency (–6 speed grade) — — 472.5 MHz PLL output frequency (–7 speed grade) — — 450 MHz PLL output frequency (–8 speed grade) — — 402.5 MHz tOUTDUTY Duty cycle for external clock output (when set to 50%) 45 50 55 % tLOCK Time required to lock from end of device configuration — — 1 ms tDLOCK Time required to lock dynamically (after switchover, reconfiguring any non-post-scale counters/delays or areset is deasserted) — — 1 ms Dedicated clock output period jitter FOUT ≥ 100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI Dedicated clock output cycle-to-cycle jitter FOUT ≥ 100 MHz — — 300 ps FOUT < 100 MHz — — 30 mUI Regular I/O period jitter FOUT ≥ 100 MHz — — 650 ps FOUT < 100 MHz — — 75 mUI Regular I/O cycle-to-cycle jitter FOUT ≥ 100 MHz — — 650 ps FOUT < 100 MHz — — 75 mUI tPLL_PSERR Accuracy of PLL phase shift — — ±50 ps tARESET Minimum pulse width on areset signal. 10 — — ns tCONF IGPLL Time required to reconfigure scan chains for PLLs — 3.5 (6) — SCANCLK cycles fSC ANC LK scanclk frequency — — 100 MHz fOUT_EXT (external clock output) (2) fOUT (to global clock) tOUTJITTER_PERIOD_DEDC LK (5) tOUTJITTER_CCJ _DEDCLK (5) tOUTJITTER_PERIOD_IO (5) tOUTJITTER_CCJ _IO (5) Parameter Notes to Table 1–23: (1) VCC D_P LL should always be connected to VC CINT through decoupling capacitor and ferrite bead. (2) This parameter is limited in the Quartus II software by the I/O maximum frequency. The maximum I/O frequency is different for each I/O standard. (3) The VCO frequency reported by the Quartus II software in the PLL summary section of the compilation report takes into consideration the VC O post-scale counter K value. Therefore, if the counter K has a value of 2, the frequency reported can be lower than the fV CO specification. (4) A high input jitter directly affects the PLL output jitter. To have low PLL output clock jitter, you must provide a clean clock source, that is less than 200 ps. (5) Peak-to-peak jitter with a probability level of 10–12 (14 sigma, 99.99999999974404% confidence level). The output jitter specification applies to the intrinsic jitter of the PLL, when an input jitter of 30 ps is applied. (6) With 100 MHz scanclk frequency. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–22 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Embedded Multiplier Specifications Table 1–24 describes the embedded multiplier specifications for Cyclone IV devices. Table 1–24. Cyclone IV Devices Embedded Multiplier Specifications —Preliminary Resources Used Performance Mode Unit Number of Multipliers C6 C7, I7 C8 9 × 9-bit multiplier 1 340 300 260 MHz 18 × 18-bit multiplier 1 287 250 200 MHz Memory Block Specifications Table 1–25 describes the M9K memory block specifications for Cyclone IV devices. Table 1–25. Cyclone IV Devices Memory Block Performance Specifications —Preliminary Resources Used Memory M9K Block Mode Performance LEs M9K Memory C6 C7, I7 C8 Unit FIFO 256 × 36 47 1 315 274 238 MHz Single-port 256 × 36 0 1 315 274 238 MHz Simple dual-port 256 × 36 CLK 0 1 315 274 238 MHz True dual port 512 × 18 single CLK 0 1 315 274 238 MHz Configuration and JTAG Specifications Table 1–26 lists the configuration mode specifications for Cyclone IV devices. Table 1–26. Cyclone IV Devices Configuration Mode Specifications —Preliminary Programming Mode DCLK f MAX Unit Passive Serial (PS) 133 MHz Fast Passive Parallel (FPP) 100 MHz Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–23 Table 1–27 lists the active configuration mode specifications for Cyclone IV devices. Table 1–27. Cyclone IV Devices Active Configuration Mode Specifications —Preliminary Programming Mode DCLK Range Unit Active Parallel (AP) 20 – 40 MHz Active Serial (AS) 20 – 40 MHz Table 1–28 lists the JTAG timing parameters and values for Cyclone IV devices. Table 1–28. Cyclone IV Devices JTAG Timing Parameters (Note 1)—Preliminary Symbol Parameter Min Max Unit tJC P TCK clock period 40 — ns tJC H TCK clock high time 20 — ns tJC L TCK clock low time 20 — ns tJP SU_TDI JTAG port setup time for TDI (2) 1 — ns tJP SU_TM S JTAG port setup time for TMS (2) 3 — ns tJP H JTAG port hold time 10 — ns tJP CO JTAG port clock to output (2) — 15 ns tJP ZX JTAG port high impedance to valid output (2) — 15 ns tJP XZ JTAG port valid output to high impedance (2) — 15 ns tJS SU Capture register setup time (2) 5 — ns tJS H Capture register hold time 10 — ns tJS CO Update register clock to output — 25 ns tJS ZX Update register high impedance to valid output — 25 ns tJS XZ Update register valid output to high impedance — 25 ns Notes to Table 1–28: (1) For more information about JTAG waveforms, refer to “JTAG Waveform” in “Glossary” on page 1–33. (2) The specification is shown for 3.3-, 3.0-, and 2.5-V LVTTL/LVCMOS operation of JTAG pins. For 1.8-V LVTTL/LVCMOS and 1.5-V LVCMOS, the JTAG port clock to output time is 16 ns. Periphery Performance This section describes periphery performance, including high-speed I/O and external memory interface. This section describes periphery performance, including high-speed I/O and external memory interface. I/O performance supports several system interfaces, such as the high-speed I/O interface, external memory interface, and the PCI/PCI-X bus interface. I/Os using SSTL-18 Class I termination standard can achieve up to the stated DDR2 SDRAM interfacing speeds as indicated in Table 1–35 and Table 1–36 on page 1–29 with typical DDR2 SDRAM memory interface setup. I/Os using general-purpose I/O standards such as 3.0-, 2.5-, 1.8-, or 1.5-LVTTL/LVCMOS are capable of typical 200 MHz interfacing frequency with a 10 pF load. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–24 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1 Actual achievable frequency depends on design- and system-specific factors. You should perform HSPICE/IBIS simulations based on your specific design and system setup to determine the maximum achievable frequency in your system. High-Speed I/O Specifications Table 1–29 through Table 1–34 list the high-speed I/O timing for Cyclone IV devices. For definitions of high-speed timing specifications, refer to “Glossary” on page 1–33. Table 1–29. Cyclone IV Devices RSDS Transmitter Timing Specifications (Note 1), (2) —Preliminary C6 Symbol C7, I7 C8 Modes fHSC LK (input clock frequency) Device operation in Mbps Unit Min Typ Max Min Typ Max Min Typ Max ×10 10 — 180 10 — 155.5 10 — 155.5 MHz ×8 10 — 180 10 — 155.5 10 — 155.5 MHz ×7 10 — 180 10 — 155.5 10 — 155.5 MHz ×4 10 — 180 10 — 155.5 10 — 155.5 MHz ×2 10 — 180 10 — 155.5 10 — 155.5 MHz ×1 10 — 360 10 — 311 10 — 311 MHz ×10 100 — 360 100 — 311 100 — 311 Mbps ×8 80 — 360 80 — 311 80 — 311 Mbps ×7 70 — 360 70 — 311 70 — 311 Mbps ×4 40 — 360 40 — 311 40 — 311 Mbps ×2 20 — 360 20 — 311 20 — 311 Mbps ×1 10 — 360 10 — 311 10 — 311 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps tRISE 20 – 80%, CLOA D = 5 pF — 500 — — 500 — — 500 — ps tFALL 20 – 80%, CLOA D = 5 pF — 500 — — 500 — — 500 — ps — — — 1 — — 1 — — 1 ms tLOCK (3) Notes to Table 1–29: (1) Applicable for true RSDS and emulated RSDS_E_3R transmitter. (2) True RSDS transmitter is only supported at output pin of Row I/O Banks 5 and 6. Emulated RSDS transmitter is supported at the output pin of I/O Banks 3, 4, 5, 6, 7, 8, and 9. (3) tLOC K is the time required for the PLL to lock from the end of device configuration. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–25 Table 1–30. Cyclone IV Devices Emulated RSDS_E_1R Transmitter Timing Specifications (Note 1) —Preliminary C6 Symbol C7, I7 C8 Modes fHSC LK (input clock frequency) Device operation in Mbps Unit Min Typ Max Min Typ Max Min Typ Max ×10 10 — 85 10 — 85 10 — 85 MHz ×8 10 — 85 10 — 85 10 — 85 MHz ×7 10 — 85 10 — 85 10 — 85 MHz ×4 10 — 85 10 — 85 10 — 85 MHz ×2 10 — 85 10 — 85 10 — 85 MHz ×1 10 — 170 10 — 170 10 — 170 MHz ×10 100 — 170 100 — 170 100 — 170 Mbps ×8 80 — 170 80 — 170 80 — 170 Mbps ×7 70 — 170 70 — 170 70 — 170 Mbps ×4 40 — 170 40 — 170 40 — 170 Mbps ×2 20 — 170 20 — 170 20 — 170 Mbps ×1 10 — 170 10 — 170 10 — 170 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps — 500 — — 500 — — 500 — ps — 500 — — 500 — — 500 — ps — — 1 — — 1 — — 1 ms tRISE tFALL 20 – 80%, CLOAD = 5 pF 20 – 80%, CLOAD = 5 pF tLOCK (2) — Notes to Table 1–30: (1) Emulated RSDS_E_1R transmitter is supported at the output pin of I/O Banks 3, 4, 5, 6, 7, 8, and 9. (2) tLOC K is the time required for the PLL to lock from the end of device configuration. Table 1–31. Cyclone IV Devices Mini-LVDS Transmitter Timing Specifications (Note 1), (2) (Part 1 of 2)—Preliminary C6 Symbol fHSC LK (input clock frequency) © November 2009 C7, I7 C8 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 10 — 200 10 — 155.5 10 — 155.5 MHz ×8 10 — 200 10 — 155.5 10 — 155.5 MHz ×7 10 — 200 10 — 155.5 10 — 155.5 MHz ×4 10 — 200 10 — 155.5 10 — 155.5 MHz ×2 10 — 200 10 — 155.5 10 — 155.5 MHz ×1 10 — 400 10 — 311 10 — 311 MHz Altera Corporation Cyclone IV Device Handbook, Volume 3 1–26 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Table 1–31. Cyclone IV Devices Mini-LVDS Transmitter Timing Specifications (Note 1), (2) (Part 2 of 2)—Preliminary C6 Symbol C7, I7 C8 Modes Unit Min Typ Max Min Typ Max Min Typ Max ×10 100 — 400 100 — 311 100 — 311 Mbps ×8 80 — 400 80 — 311 80 — 311 Mbps ×7 70 — 400 70 — 311 70 — 311 Mbps ×4 40 — 400 40 — 311 40 — 311 Mbps ×2 20 — 400 20 — 311 20 — 311 Mbps ×1 10 — 400 10 — 311 10 — 311 Mbps tDUTY — 45 — 55 45 — 55 45 — 55 % TCCS — — — 200 — — 200 — — 200 ps Output jitter (peak to peak) — — — 500 — — 500 — — 550 ps — 500 — — 500 — — 500 — ps — 500 — — 500 — — 500 — ps — — 1 — — 1 — — 1 ms Device operation in Mbps tRISE tFALL 20 – 80%, CLOAD = 5 pF 20 – 80%, CLOAD = 5 pF tLOCK (3) — Notes to Table 1–31: (1) Applicable for true and emulated mini-LVDS transmitter. (2) True mini-LVDS transmitter is only supported at the output pin of Row I/O Banks 5 and 6. Emulated mini-LVDS transmitter is supported at the output pin of I/O Banks 3, 4, 5, 6, 7, 8, and 9. (3) tLOC K is the time required for the PLL to lock from the end of device configuration. Table 1–32. Cyclone IV Devices True LVDS Transmitter Timing Specifications (Note 1) (Part 1 of 2) —Preliminary C6 Symbol fHSC LK (input clock frequency) HSIODR C7, I7 C8 Modes Unit Min Max Min Max Min Max ×10 10 420 10 370 10 320 MHz ×8 10 420 10 370 10 320 MHz ×7 10 420 10 370 10 320 MHz ×4 10 420 10 370 10 320 MHz ×2 10 420 10 370 10 320 MHz ×1 10 420 10 402.5 10 402.5 MHz ×10 100 840 100 740 100 640 Mbps ×8 80 840 80 740 80 640 Mbps ×7 70 840 70 740 70 640 Mbps ×4 40 840 40 740 40 640 Mbps ×2 20 840 20 740 20 640 Mbps ×1 10 420 10 402.5 10 402.5 Mbps tDUTY — 45 55 45 55 45 55 % TCCS — — 200 — 200 — 200 ps Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–27 Table 1–32. Cyclone IV Devices True LVDS Transmitter Timing Specifications (Note 1) (Part 2 of 2) —Preliminary C6 Symbol C7, I7 C8 Modes Unit Min Max Min Max Min Max Output jitter (peak to peak) — — 500 — 500 — 550 ps tLOCK (2) — — 1 — 1 — 1 ms Notes to Table 1–32: (1) True LVDS transmitter is only supported at the output pin of Row I/O Banks 5 and 6. (2) tLOC K is the time required for the PLL to lock from the end of device configuration. Table 1–33. Cyclone IV Devices Emulated LVDS Transmitter Timing Specifications (Note 1) —Preliminary C6 Symbol fHSC LK (input clock frequency) HSIODR C7, I7 C8 Modes Unit Min Max Min Max Min Max ×10 10 320 10 320 10 275 MHz ×8 10 320 10 320 10 275 MHz ×7 10 320 10 320 10 275 MHz ×4 10 320 10 320 10 275 MHz ×2 10 320 10 320 10 275 MHz ×1 10 402.5 10 402.5 10 402.5 MHz ×10 100 640 100 640 100 550 Mbps ×8 80 640 80 640 80 550 Mbps ×7 70 640 70 640 70 550 Mbps ×4 40 640 40 640 40 550 Mbps ×2 20 640 20 640 20 550 Mbps ×1 10 402.5 10 402.5 10 402.5 Mbps tDUTY — 45 55 45 55 45 55 % TCCS — — 200 — 200 — 200 ps Output jitter (peak to peak) — — 500 — 500 — 550 ps tLOCK (2) — — 1 — 1 — 1 ms Notes to Table 1–33: (1) Emulated LVDS transmitter is supported at the output pin of I/O Banks 3, 4, 5, 6, 7, 8, and 9. (2) tLOC K is the time required for the PLL to lock from the end of device configuration. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–28 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Table 1–34. Cyclone IV Devices LVDS Receiver Timing Specifications (Note 1) —Preliminary C6 Symbol C7, I7 C8 Modes Unit Min Max Min Max Min Max ×10 10 437.5 10 370 10 320 MHz ×8 10 437.5 10 370 10 320 MHz ×7 10 437.5 10 370 10 320 MHz ×4 10 437.5 10 370 10 320 MHz ×2 10 437.5 10 370 10 320 MHz ×1 10 437.5 10 402.5 10 402.5 MHz ×10 100 875 100 740 100 640 Mbps ×8 80 875 80 740 80 640 Mbps ×7 70 875 70 740 70 640 Mbps ×4 40 875 40 740 40 640 Mbps ×2 20 875 20 740 20 640 Mbps ×1 10 437.5 10 402.5 10 402.5 Mbps SW — — 400 — 400 — 400 ps Input jitter tolerance — — 500 — 500 — 550 ps tLOCK (2) — — 1 — 1 — 1 ms fHSC LK (input clock frequency) HSIODR Notes to Table 1–34: (1) LVDS receiver is supported at I/O Banks 3, 4, 5, 6, 7, 8, and 9. (2) tLOC K is the time required for the PLL to lock from the end of device configuration. External Memory Interface Specifications Cyclone IV devices support external memory interfaces up to 200 MHz. The external memory interfaces for Cyclone IV devices are auto-calibrating and easy to implement. Table 1–35 through Table 1–39 list the external memory interface specifications for Cyclone IV devices and are useful when performing memory interface timing analysis. Table 1–35. Cyclone IV Devices Maximum Clock Rate Support for External Memory Interfaces with Half-Rate Controller (Note 1),(2) (Part 1 of 2) —Preliminary Column I/O Banks Row I/O Banks Wraparound Mode Column I/O Banks Row I/O Banks Wraparound Mode Column I/O Banks Row I/O Banks Wraparound Mode I7 Speed Grade (MHz) Wraparound Mode C8 Speed Grade (MHz) Row I/O Banks C7 Speed Grade (MHz) Column I/O Banks C6 Speed Grade (MHz) DDR2 SDRAM (3),(4) 200 167 167 167 150 133 167 133 125 167 150 133 DDR SDRAM (3) 167 150 133 150 133 125 133 125 100 150 133 125 Memory Standard Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–29 Table 1–35. Cyclone IV Devices Maximum Clock Rate Support for External Memory Interfaces with Half-Rate Controller (Note 1),(2) (Part 2 of 2) —Preliminary Column I/O Banks Row I/O Banks Wraparound Mode Column I/O Banks Row I/O Banks Wraparound Mode Column I/O Banks Row I/O Banks Wraparound Mode I7 Speed Grade (MHz) Wraparound Mode QDR II SRAM (5) C8 Speed Grade (MHz) Row I/O Banks Memory Standard C7 Speed Grade (MHz) Column I/O Banks C6 Speed Grade (MHz) 167 167 150 150 150 133 133 133 125 150 150 133 Notes to Table 1–35: (1) Column I/O banks refer to top and bottom I/Os. Row I/O banks refer to right I/Os. Wraparound mode refers to combination of column and row I/Os. (2) The supported operating frequencies listed here are memory interface maximums for the FPGA device. The actual achievable performance of your design is based on the design and system specific factors, as well as static timing analysis of the completed design. (3) The values apply for interfaces with both modules and components. (4) For more information about the required DDR2 memory device speed grade for external memory interface to achieve performance as stated in this table, refer to AN 445: Design Guidelines for Implementing DDR and DDR2 SDRAM Interfaces in Cyclone III Devices. (5) QDR II SRAM also supports the 1.5-V HSTL I/O standard. However, Altera recommends using the 1.8-V HSTL I/O standard for maximum performance because of the higher I/O drive strength. Table 1–36. Cyclone IV Devices Maximum Clock Rate Support for External Memory Interfaces with Full-Rate Controller (Note 1),(2) —Preliminary Row I/O Banks Column I/O Banks Row I/O Banks Column I/O Banks Row I/O Banks I7 Speed Grade (MHz) Column I/O Banks C8 Speed Grade (MHz) Row I/O Banks C7 Speed Grade (MHz) Column I/O Banks C6 Speed Grade (MHz) DDR2 SDRAM (3),(4),(5) 200 167 167 150 167 133 167 150 DDR SDRAM (3) 167 150 150 133 133 125 150 133 Memory Standard Notes to Table 1–36: (1) Column I/O banks refer to top and bottom I/Os. Row I/O banks refer to right I/Os. (2) The supported operating frequencies listed here are memory interface maximums for the FPGA device. The actual achievable performance of your design is based on the design and system specific factors, as well as static timing analysis of the completed design. (3) The values apply for interfaces with both modules and components. (4) We recommend the use of ALTMEMPHY AFI mode to achieve these quoted maximum clock rate due to lower performance of Non-AFI mode. (5) For the required DDR2 memory device speed grade for external memory interface to achieve performance as stated in this table, refer to AN 445: Design Guidelines for Implementing DDR and DDR2 SDRAM Interfaces in Cyclone IV Devices. Table 1–37. Cyclone IV Devices FPGA Sampling Window (SW) Requirement – Read Side (Note 1) —Preliminary (Part 1 of 2) Column I/Os Row I/Os Wraparound Mode Memory Standard Setup Hold Setup Hold Setup Hold 640 850 800 C6 Speed Grade DDR2 SDRAM © November 2009 580 Altera Corporation 550 690 Cyclone IV Device Handbook, Volume 3 1–30 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Table 1–37. Cyclone IV Devices FPGA Sampling Window (SW) Requirement – Read Side (Note 1) —Preliminary (Part 2 of 2) Column I/Os Row I/Os Wraparound Mode Memory Standard Setup Hold Setup Hold Setup Hold DDR SDRAM 585 535 700 650 870 820 QDR II SRAM 785 735 805 755 905 855 C7 Speed Grade DDR2 SDRAM 705 650 770 715 985 930 DDR SDRAM 675 620 795 740 970 915 QDR II SRAM 900 845 910 855 1085 1030 C8 Speed Grade DDR2 SDRAM 785 720 930 870 1115 1055 DDR SDRAM 800 740 915 855 1185 1125 QDR II SRAM 1050 990 1065 1005 1210 1150 I7 Speed Grade DDR2 SDRAM 765 710 855 800 1040 985 DDR SDRAM 745 690 880 825 1000 945 QDR II SRAM 945 890 955 900 1130 1075 QDR II SRAM 1090 1030 1105 1045 1250 1190 Note to Table 1–37: (1) Column I/Os refer to top and bottom I/Os. Row I/Os refer to right I/Os. Wraparound mode refers to the combination of column and row I/Os. Table 1–38. Cyclone IV Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (Note 1) (Part 1 of 2) —Preliminary Memory Standard Column I/Os (ps) Row I/Os (ps) Wraparound Mode (ps) I/O Standard Lead Lag Lead Lag Lead Lag C6 Speed Grade DDR2 SDRAM DDR SDRAM QDR II SRAM SSTL-18 Class I 790 380 790 380 890 480 SSTL-18 Class II 870 490 870 490 970 590 SSTL-2 Class I 750 320 750 320 850 420 SSTL-2 Class II 860 350 860 350 960 450 1.8 V HSTL Class I 780 410 780 410 880 510 1.8 V HSTL Class II 830 510 830 510 930 610 SSTL-18 Class I 915 410 915 410 1015 510 SSTL-18 Class II 1025 545 1025 545 1125 645 SSTL-2 Class I 880 340 880 340 980 440 SSTL-2 Class II 1010 380 1010 380 1110 480 1.8 V HSTL Class I 910 450 910 450 1010 550 1.8 V HSTL Class II 1010 570 1010 570 1110 670 C7 Speed Grade DDR2 SDRAM DDR SDRAM QDR II SRAM Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Switching Characteristics 1–31 Table 1–38. Cyclone IV Devices Transmitter Channel-to-Channel Skew (TCCS) – Write Side (Note 1) (Part 2 of 2) —Preliminary Column I/Os (ps) Memory Standard Row I/Os (ps) Wraparound Mode (ps) I/O Standard Lead Lag Lead Lag Lead Lag C8 Speed Grade DDR2 SDRAM DDR SDRAM QDR II SRAM SSTL-18 Class I 1040 440 1040 440 1140 540 SSTL-18 Class II 1180 600 1180 600 1280 700 SSTL-2 Class I 1010 360 1010 360 1110 460 SSTL-2 Class II 1160 410 1160 410 1260 510 1.8 V HSTL Class I 1040 490 1040 490 1140 590 1.8 V HSTL Class II 1190 630 1190 630 1290 730 SSTL-18 Class I 961 431 961 431 1061 531 SSTL-18 Class II 1076 572 1076 572 1176 672 SSTL-2 Class I 924 357 924 357 1024 457 SSTL-2 Class II 1061 399 1061 399 1161 499 1.8 V HSTL Class I 956 473 956 473 1056 573 1.8 V HSTL Class II 1061 599 1061 599 1161 699 I7 Speed Grade DDR2 SDRAM DDR SDRAM QDR II SRAM Notes to Table 1–38: (1) Column I/O banks refer to top and bottom I/Os. Row I/O banks refer to right I/Os. Wraparound mode refers to the combination of column and row I/Os. (2) For DDR2 SDRAM write timing performance on columns I/O for C8 devices, 97.5° phase offset is required. Table 1–39. Cyclone IV Devices Memory Output Clock Jitter Specifications (Note 1), (2) — Preliminary Parameter Symbol Min Max Unit Clock period jitter tJIT(per) –125 125 ps Cycle-to-cycle period jitter tJIT(cc) –200 200 ps Duty cycle jitter t JIT(duty) –150 150 ps Notes to Table 1–39: (1) The memory output clock jitter measurements are for 200 consecutive clock cycles, as specified in the JEDEC DDR2 standard. (2) The clock jitter specification applies to memory output clock pins generated using DDIO circuits clocked by a PLL output routed on a global clock network. © November 2009 Altera Corporation Cyclone IV Device Handbook, Volume 3 1–32 Chapter 1: Cyclone IV Device Datasheet Switching Characteristics Duty Cycle Distortion Specifications Table 1–40 lists the worst case duty cycle distortion for Cyclone IV devices. Table 1–40. Duty Cycle Distortion on Cyclone IV Devices I/O Pins (Note 1), (2)—Preliminary C6 C7, I7 C8 Symbol Unit Output Duty Cycle Min Max Min Max Min Max 45 55 45 55 45 55 % Notes to Table 1–40: (1) Duty cycle distortion specification applies to clock outputs from PLLs, global clock tree, and IOE driving dedicated and general purpose I/O pins. (2) Cyclone IV devices meet specified duty cycle distortion at maximum output toggle rate for each combination of I/O standard and current strength. OCT Calibration Timing Specification Table 1–41 lists the duration of calibration for series OCT with calibration at device power-up for Cyclone IV devices. Table 1–41. Cyclone IV Devices Timing Specification for Series OCT with Calibration at Device Power-Up (Note 1)—Preliminary Symbol Description Maximum Units 20 µs Duration of series OCT with calibration at device power-up tOCTC AL Note to Table 1–41: (1) OCT calibration takes place after device configuration, before entering user mode. IOE Programmable Delay Table 1–42 and Table 1–43 list the IOE programmable delay for Cyclone IV devices. Table 1–42. Cyclone IV Devices IOE Programmable Delay on Column Pins (Note 1), (2)—Preliminary Max Offset Parameter Paths Affected Number of Settings Min Offset Fast Corner Slow Corner Unit I7 C6 C6 C7 C8 I7 Input delay from pin to internal cells Pad to I/O dataout to core 7 0 1.211 1.314 2.175 2.32 2.386 2.366 ns Input delay from pin to input register Pad to I/O input register 8 0 1.203 1.307 2.19 2.387 2.54 2.43 ns Delay from output register to output pin I/O output register to pad 2 0 0.479 0.504 0.915 1.011 1.107 1.018 ns Input delay from dual-purpose clock pin to fan-out destinations Pad to global clock network 12 0 0.664 0.694 1.199 1.378 1.532 1.392 ns Notes to Table 1–42: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of the Quartus II software. (2) The minimum and maximum offset timing numbers are in reference to setting ‘0’ as available in the Quartus II software. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet I/O Timing 1–33 Table 1–43. Cyclone IV Devices IOE Programmable Delay on Row Pins (Note 1), (2)—Preliminary Max Offset Paths Affected Parameter Number of Settings Min Offset Fast Corner Slow Corner Unit I7 C6 C6 C7 C8 I7 Input delay from pin to internal cells Pad to I/O dataout to core 7 0 1.209 1.314 2.174 2.335 2.406 2.381 ns Input delay from pin to input register Pad to I/O input register 8 0 1.207 1.312 2.202 2.402 2.558 2.447 ns Delay from output register to output pin I/O output register to pad 2 0 0.51 0.537 0.962 1.072 1.167 1.074 ns 12 0 0.669 0.698 1.207 1.388 1.542 1.403 ns Input delay from Pad to global dual-purpose clock pin clock network to fan-out destinations Notes to Table 1–43: (1) The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of Quartus II software. (2) The minimum and maximum offset timing numbers are in reference to setting ‘0’ as available in the Quartus II software I/O Timing You can use the following methods to determine the I/O timing: ■ the Excel-based I/O Timing ■ the Quartus II timing analyzer The Excel-based I/O Timing provides pin timing performance for each device density and speed grade. The data is typically used prior to designing the FPGA to get a timing budget estimation as part of the link timing analysis. The Quartus II timing analyzer provides a more accurate and precise I/O timing data based on the specifics of the design after place-and-route is complete. f The Excel-based I/O Timing spreadsheet is downloadable from Cyclone IV Devices Literature website. Glossary Table 1–44 lists the glossary for this chapter. Table 1–44. Glossary (Part 1 of 6) Letter Term Definitions A — — B — — C — — D — — E — — F fHS CLK © November 2009 HIGH-SPEED I/O Block: High-speed receiver/transmitter input and output clock frequency. Altera Corporation Cyclone IV Device Handbook, Volume 3 1–34 Chapter 1: Cyclone IV Device Datasheet Glossary Table 1–44. Glossary (Part 2 of 6) Letter Term Definitions GCLK Input pin directly to Global Clock network. GCLK PLL Input pin to Global Clock network through PLL. H HSIODR HIGH-SPEED I/O Block: Maximum/minimum LVDS data transfer rate (HSIODR = 1/TUI). I Input Waveforms for the SSTL Differential I/O Standard G VIH VSWING VREF VIL TMS TDI t JCP t JCH t JPSU_TDI t JPSU_TMS t JCL t JPH TCK J JTAG Waveform tJPZX t JPXZ t JPCO TDO tJSSU Signal to be Captured tJSZX t JSH t JSCO t JSXZ Signal to be Driven K — — L — — M — — N — — O — — Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Glossary 1–35 Table 1–44. Glossary (Part 3 of 6) Letter Term Definitions The following block diagram highlights the PLL Specification parameters. CLKOUT Pins Switchover fOUT _EXT CLK fIN N fINPFD PFD P PLL Block CP VCO fVCO LF Core Clock Counters C0..C4 fOUT GCLK Phase tap M Key Reconfigurable in User Mode Q — RL — Receiver differential input discrete resistor (external to Cyclone IV devices). Receiver Input Waveform for LVDS and LVPECL Differential Standards. Single-Ended Waveform Positive Channel (p) = VIH VID Negative Channel (n) = VIL VCM R Ground Receiver Input Waveform Differential Waveform (Mathematical Function of Positive & Negative Channel) VID 0V VID p -n RSKM (Receiver input skew margin) © November 2009 HIGH-SPEED I/O Block: The total margin left after accounting for the sampling window and TCCS. RSKM = (TUI – SW – TCCS) / 2. Altera Corporation Cyclone IV Device Handbook, Volume 3 1–36 Chapter 1: Cyclone IV Device Datasheet Glossary Table 1–44. Glossary (Part 4 of 6) Letter Term Definitions VCCIO VOH VIH (AC ) VIH(DC) VREF S VIL(DC) VIL(AC ) Single-ended voltagereferenced I/O Standard VOL VSS The JEDEC standard for SSTl and HSTL I/O standards defines both the AC and DC input signal values. The AC values indicate the voltage levels at which the receiver must meet its timing specifications. The DC values indicate the voltage levels at which the final logic state of the receiver is unambiguously defined. After the receiver input crosses the AC value, the receiver changes to the new logic state. The new logic state is then maintained as long as the input stays beyond the DC threshold. This approach is intended to provide predictable receiver timing in the presence of input waveform ringing. T SW (Sampling Window) HIGH-SPEED I/O Block: The period of time during which the data must be valid to capture it correctly. The setup and hold times determine the ideal strobe position in the sampling window. tC High-speed receiver/transmitter input and output clock period. TCCS (Channelto-channel-skew) HIGH-SPEED I/O Block: The timing difference between the fastest and slowest output edges, including t C O variation and clock skew. The clock is included in the TCCS measurement. tcin Delay from clock pad to I/O input register. tC O Delay from clock pad to I/O output. tcout Delay from clock pad to I/O output register. tDUTY HIGH-SPEED I/O Block: Duty cycle on high-speed transmitter output clock. tFA LL Signal high-to-low transition time (80–20%). tH Input register hold time. Timing Unit Interval (TUI) HIGH-SPEED I/O block: The timing budget allowed for skew, propagation delays, and data sampling window. (TUI = 1/(Receiver Input Clock Frequency Multiplication Factor) = tC /w). tINJITTER Period jitter on PLL clock input. tOUTJITTER_DEDC LK Period jitter on dedicated clock output driven by a PLL. tOUTJITTER_IO Period jitter on general purpose I/O driven by a PLL. tpllcin Delay from PLL inclk pad to I/O input register. tpllcout Delay from PLL inclk pad to I/O output register. Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Glossary 1–37 Table 1–44. Glossary (Part 5 of 6) Letter Term Definitions Transmitter Output Waveforms for the LVDS, mini-LVDS, PPDS and RSDS Differential I/O Standards Single-Ended Waveform Positive Channel (p) = VOH VOD Negative Channel (n) = VOL Vos Transmitter Output Waveform Ground Differential Waveform (Mathematical Function of Positive & Negative Channel) VOD 0V VOD p -n tRISE Signal low-to-high transition time (20–80%). tS U Input register setup time. U © November 2009 — Altera Corporation — Cyclone IV Device Handbook, Volume 3 1–38 Chapter 1: Cyclone IV Device Datasheet Glossary Table 1–44. Glossary (Part 6 of 6) Letter V Term Definitions VC M( DC) DC Common Mode Input Voltage. VDIF( AC ) AC differential Input Voltage: The minimum AC input differential voltage required for switching. VDIF( DC) DC differential Input Voltage: The minimum DC input differential voltage required for switching. VIC M Input Common Mode Voltage: The common mode of the differential signal at the receiver. VID Input differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the receiver. VIH Voltage Input High: The minimum positive voltage applied to the input that is accepted by the device as a logic high. VIH(A C) High-level AC input voltage. VIH(DC ) High-level DC input voltage. VIL Voltage Input Low: The maximum positive voltage applied to the input that is accepted by the device as a logic low. VIL ( AC ) Low-level AC input voltage. VIL ( DC) Low-level DC input voltage. VIN DC input voltage. VOC M Output Common Mode Voltage: The common mode of the differential signal at the transmitter. VOD Output differential Voltage Swing: The difference in voltage between the positive and complementary conductors of a differential transmission at the transmitter. VOD = VOH – VOL. VOH Voltage Output High: The maximum positive voltage from an output that the device considers is accepted as the minimum positive high level. VOL Voltage Output Low: The maximum positive voltage from an output that the device considers is accepted as the maximum positive low level. VOS Output offset voltage: VOS = (VOH + VOL) / 2. VOX ( AC) AC differential Output cross point voltage: The voltage at which the differential output signals must cross. VREF Reference voltage for SSTL, HSTL I/O Standards. VREF (A C) AC input reference voltage for SSTL, HSTL I/O Standards. VREF (AC ) = VREF (DC) + noise. The peak-to-peak AC noise on VREF should not exceed 2% of VREF (DC). VREF (DC ) DC input reference voltage for SSTL, HSTL I/O Standards. VS WING (A C) AC differential Input Voltage: AC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VS WING (DC ) DC differential Input Voltage: DC Input differential voltage required for switching. For the SSTL Differential I/O Standard, refer to Input Waveforms. VTT Termination voltage for SSTL, HSTL I/O Standards. VX ( AC) AC differential Input cross point Voltage: The voltage at which the differential input signals must cross. W — — X — — Y — — Z — — Cyclone IV Device Handbook, Volume 3 © November 2009 Altera Corporation Chapter 1: Cyclone IV Device Datasheet Chapter Revision History 1–39 Chapter Revision History Table 1–45 lists the revision history for this chapter. Table 1–45. Chapter Revision History Date Version November 2009 1.0 © November 2009 Altera Corporation Changes Made Initial release. Cyclone IV Device Handbook, Volume 3 1–40 Cyclone IV Device Handbook, Volume 3 Chapter 1: Cyclone IV Device Datasheet Chapter Revision History © November 2009 Altera Corporation