Optic Fiber Converters for DSC POWER, PARADOX EVO, SATEL INTEGRA Buses BREAK-TDW and RDW-PDS BOX* BOX + DIN35-LOCK* ▪ Digital modulation ▪ MM/SM universal (WDM) ▪ 2x data BUS (0-10V) ▪ 1x Relay LOCK NO/NC ▪ Overvoltage protection ▪ Current limiter in supply ▪ Working temperature from – 40°C to +70°C ORDERING NAME CODE SUPPLY FIWRE-PDS* 1-004-220 10-20VDC** BREAK-TDW-PDS-BOX 1-504-274 10-20VDC** BREAK-RDW-PDS-BOX 1-604-275 10-20VDC** * set of converters; holders for mounting to DIN35 included ** BUS supply Connection to the KEYBUS bus of DSC POWER system RED. BLK. YEL. GRN. BUS KEYBUS TDW-PDS-BOX 1x MM/SM 1 +13,85V BLK. YEL. GRN. RDW-PDS-BOX M1 M2 system keyboards and modules Connection to the BUS bus of PARADOX EVO system RED. BLK. YEL. GRN. BUS EVO TDW-PDS-BOX 1x MM/SM1 +12V BLK. YEL. GRN. RDW-PDS-BOX M1 M2 system keyboards and modules Connection to the expander’s bus of SATEL INTEGRA system BUS INTEGRA BUS2 BUS1 +KPD COM. DTM. CKM. BUS1 TDW-PDS-BOX 1x MM/SM1 +12V COM. DTM. CKM. RDW-PDS-BOX BUS2 DT1 M1 M2 Compatible system keyboards and modules CK1 +12V COM. DAT. CLK 1 POWER: max. 6/15km, EVO: max. 6/10km, INTEGRA: max. 6/6km (MM/SM) www.metel.eu 1/7 Exp1 Exp2 Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA Description and technical parameters Optic fiber converters for transmission of system buses of alarm systems DSC POWER, PARADOX EVO and SATEL INTEGRA. Parameter Value Unit Note BUS Overvoltage protections 600 W pulse 10/1000 μs Optics Output optical power –14 to –8 / –10 to 0 dBm SM / MM Sensitivity –31 dBm SM / MM Optical fibres 1x SM 9/125 - SC connectors µm grinding PC Optical range Topology 1x MM 50(62.5)/125 - SC conn. µm grinding PC DSC POWER 15 / 6 (6) km SM / MM (BUS) PARADOX EVO 10 / 6 (6) km SM / MM (BUS) SATEL INTEGRA 6 / 6 (6) km SM / MM (BUS) STAR max. 4 sets BUS max. 4 sets ATTENTION: class 1 LASER PRODUCT COMPLIES WITH 21 CFR 1040.10 and 1040.11 DEN 60825-1-1E LOCK Relay NO/NC contact max. 125VAC/0.5A or 60VDC/0.3A Power Suply Voltage 10-20 VDC Current at 12VDC Max. 100 mA Protections overvoltage / current Operational range –40..+70 °C NC contact closed = communication OK Environment 600W-pulse 10/1000 μs/reversible Humidity max. 95 (non-condensing) % Mechanical Dimensions - w / h / l 110 x 97 x 30 (37) mm Parameters Weight typ: 0.2 kg The producer retains the right to change any technical parameters without previous announcement. www.metel.eu 2/7 from bus temperature of environment (with DIN holder) Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA Installation and Setting 4. Connect signal wires Proceed according to the type of alarm system with the pictures on the following pages. Connect the data lines from the alarm system to TDWPDS to terminals DATA1 and DATA2. If needed, terminate the data lines with a PULL-UP resistor on the xDW-PDS terminal board on the modules side (on the alarm system side – do not terminate). 1. Mounting Place TDW-PDS to the side of the alarm system. Place RDW-PDS to the side of modules (keyboards, modules...). Mount the converters to either flat surface or DIN35 rail. 2. Connect supply 12VDC between V+ and GND terminals. Connection of the supply is indicated by the yellow LED POWER switching on. 5. Indications LED PWR - by switching on detects supply LED LOCK - by switching on detects relay closure - by switching on detects optics interruption - by switching on detects failure of a remote device LED DATA1 - data line - red LED Tx blinking – data transmission - green LED Rx blinking – data reception LED DATA2 - data line - red LED Tx blinking – data transmission - green LED Rx blinking – data reception Overvoltage protections are grounded through the GND terminal. 3. Connect optic fiber terminated by a SC connector (grinding PC). After interconnection of TDW-PDS and RDW-PDS LED LOCK switches off. The reach of the fiber is changing with the number of optoconverters sets used. The length of the optical fiber in a system for 4 sets connected in series in a bus is max. 6km for both SM and MM fiber. Using of more than 4 pairs of sets in a bus is not recommended. In star topology it is possible to connect max. 16 optoconverters sets to an alarm system. TDW-PDS Tx - 1310nm Rx - 1550nm RDW-PDS Tx - 1550nm Rx - 1310nm PORT2 GROUND DATA BUS2 < +10-20VDC RELAY max. 125VAC / 0.5A max. 60VDC / 0.3A WHEN IS - LOCAL DEVICE IN DE-ENERGIZED STATE - REMOTE DEVICE IS IN FAILURE - OPTICS IS CORRUPTED COM AND NO ARE CONNECTED. PORT1 GROUND DATA BUS1 < +10-20VDC WHEN IS - LOCAL DEVICE IS POWERED - REMOTE DEVICE IS WORKING - OPTICS IS OK COM AND NC ARE CONNECTED. www.metel.eu 3/7 Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA DSC POWER TDW-PDS PORT2 PORT1 RED BLK YEL GRN FIBRE OPTIC SM 15km / MM 6km 13,85VDC + 1k RED BLK YEL GRN 1k PORT2 PORT1 TERMINATION 2x PULL-UP 1kΩ RDW-PDS A BUS CONNECTION AND TERMINATION MAIN board MODULE RED. BLK. YEL. GRN. TDW-PDSBOX RDW-PDSBOX MODULE MODULE 1k 1k 1k 1k 1k 1k 1k 1k TDW-PDSBOX RDW-PDSBOX TDW-PDSBOX RDW-PDSBOX FIBRE OPTIC max. SM 6km / MM 6km www.metel.eu MODULE 4/7 TDW-PDSBOX RDW-PDSBOX Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA PARADOX DIGIPLEX EVO TDW-PDS PORT2 PORT1 RED BLK GRN YEL FIBRE OPTIC SM 10km / MM 6km 12VDC + 1k RED BLK GRN YEL 1k PORT2 PORT1 RDW-PDS A BUS CONNECTION MAIN board MODULE RED. BLK. YEL. GRN. TDW-PDSBOX RDW-PDSBOX MODULE MODULE 1k 1k 1k 1k 1k 1k 1k 1k TDW-PDSBOX RDW-PDSBOX TDW-PDSBOX RDW-PDSBOX FIBRE OPTIC max. SM 6km / MM 6km www.metel.eu MODULE 5/7 TDW-PDSBOX RDW-PDSBOX Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA SATEL INTEGRA TDW-PDS PORT2 PORT1 COM +KPD DTM CKM DT1 CK1 FIBRE OPTIC SM 6km / MM 6km EXPANDER EXPANDER +12V COM DAT CLK 12VDC + +KPD COM CKM DTM PORT2 PORT1 RDW-PDS A BUS CONNECTION MAIN board MODULE MODULE MODULE MODULE RED. BLK. YEL. GRN. TDW-PDSBOX RDW-PDSBOX TDW-PDSBOX RDW-PDSBOX TDW-PDSBOX RDW-PDSBOX FIBRE OPTIC max. SM 6km / MM 6km www.metel.eu 6/7 TDW-PDSBOX RDW-PDSBOX Installation manual REV:201203 BREAK-TDW-PDS, BREAK-RDW-PDS Optoconverters DSC POWER, PARADOX EVO, SATEL INTEGRA 119.00 30.00 xDW-PDS-BOX + DIN35-LOCK 73.00 73.00 xDW-PDS-BOX 109.00 REVISION: 20110727 - PDS, 20111128 – PULL-UP 1kΩ www.metel.eu 7/7