Installation Manua MCIS DNC - Siemens Industry Online Support

advertisement
1
___________________
Precondition
MCIS DNC
2
___________________
Introduction
Installation on SINUMERIK
3
___________________
Operate
SINUMERIK
Configuration on
4
___________________
SINUMERIK Operate
Motion Control Information System
MCIS DNC
5
___________________
Log on user
6
___________________
Synchronizing data
Installation Manual
7
___________________
Stopping ePS Services
8
___________________
Update of MCIS DNC
9
___________________
Uninstalling DNC
Applies to:
SINUMERIK 840D sl / 840DE sl control
Software
MCIS DNC
Version
2.4.1
as of SINUMERIK Operate on the PCU
as of SINUMERIK Operate on the NCU
2.6 SP1 HF5
2.6 SP1 HF6
09/2011
Legal information
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the relevant information is not taken into account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Ⓟ 10/2011
Copyright © Siemens AG 2011.
Technical data subject to change
Table of contents
1
Precondition............................................................................................................................................... 5
1.1
Licensing ........................................................................................................................................5
2
Introduction................................................................................................................................................ 7
3
Installation on SINUMERIK Operate .......................................................................................................... 9
4
3.1
Preparing for installation on SINUMERIK Operate ........................................................................9
3.2
Installing the MCIS basis software...............................................................................................11
3.3
Installing MCIS applications.........................................................................................................13
Configuration on SINUMERIK Operate.................................................................................................... 19
4.1
Configuring URL settings .............................................................................................................19
4.2
Configuring proxy settings ...........................................................................................................21
5
Log on user.............................................................................................................................................. 23
6
Synchronizing data .................................................................................................................................. 25
7
Stopping ePS Services ............................................................................................................................ 27
8
Update of MCIS DNC .............................................................................................................................. 29
9
Uninstalling DNC ..................................................................................................................................... 31
MCIS DNC
Installation Manual, 09/2011
3
Table of contents
MCIS DNC
4
Installation Manual, 09/2011
Precondition
1.1
1
Licensing
Licensing MCIS DNC
The General License Conditions of Siemens AG automation engineering can be found on
the CD-ROM in the particular language of the country under <CD-ROM>:\License_xy-XY.txt
(xy stands for the language code, e.g. de = German).
MCIS DNC
Installation Manual, 09/2011
5
Precondition
1.1 Licensing
MCIS DNC
6
Installation Manual, 09/2011
2
Introduction
Overview for NCU
The MCIS DNC software is supplied on a CD-ROM.
● Copy the contents of the \SolutionLine directory on the CD-ROM to a directory on the
system CompactFlash card for SINUMERIK Operate, e.g. System CF-Card/user.
Overview for PCU
● If the controller does not have a CD-ROM drive, copy the contents of the CD-ROM via a
PG to a separate directory on the hard disk of the PCU.
Start the installation from the PCU.
Once the installation has completed, delete the directory again to release storage space
on the hard disk.
- OR ● If the controller is integrated in a network, start the installation from there.
● In all cases, read the supplied "siemens.txt" readme file!
Installation (PCU)
● Install any required additional components first.
● Make a backup of the system.
● Start the controller in service mode.
Note
Start the controller again in service mode if, after installing Microsoft® database access
components, a system reset is performed. Setup does not set the service mode.
Start setup using the parameter "/continue". Setup is continued at the point at which
installation was interrupted.
Note
If a setup dialog that recommends a restart is displayed after installation has been
completed, this restart must be performed.
Acknowledge this dialog.
The setup automatically performs the restart.
MCIS DNC
Installation Manual, 09/2011
7
Introduction
MCIS DNC
8
Installation Manual, 09/2011
Installation on SINUMERIK Operate
3.1
3
Preparing for installation on SINUMERIK Operate
With SINUMERIK Operate, you have the option of directly installing the MCIS base software
via the user interface.
Installation is performed via the ePS Client.
Precondition
The ePS Client must be activated on SINUMERIK Operate.
More information on activating the ePS Network Services software can be found in the
following documentation:
References
Commissioning Manual Base Software and Operator Software, SINUMERIK Operate
Starting ePS Network Services
1.
SINUMERIK Operate is started.
2.
Press the menu forward key.
3.
Press the "Network Services" softkey.
The "ePS Network Services" window is displayed.
4.
Press the "Settings" softkey.
The "ePS Network Settings" window opens and the system status
displayed.
5.
Press the "Client Settings" softkey to start the preparations for
installation.
The "ePS Network Settings" window opens and the system status
displayed.
6.
If ePS Services is not activated, press the "Start ePS Services" softkey.
You receive a confirmation prompt: "Do you want to start ePS Services
on this device?"
MCIS DNC
Installation Manual, 09/2011
9
Installation on SINUMERIK Operate
3.1 Preparing for installation on SINUMERIK Operate
7.
Press the "OK" softkey to start ePS Services.
In the "ePS Network Settings" window, you receive the message "ePS
Services activated".
- OR Press the "Cancel" softkey.
ePS Services is not started and the previous window is opened.
MCIS DNC
10
Installation Manual, 09/2011
Installation on SINUMERIK Operate
3.2 Installing the MCIS basis software
3.2
Installing the MCIS basis software
Precondition
The following applications are active:
● ePS Services
● MCIS
See
Preparing for installation on SINUMERIK Operate (Page 9)
Installing the MCIS basis software
1.
When ePS Services is activated, press the "MCIS Base Installation"
softkey.
You will receive a status message, whether and which MCIS basic
software is installed.
2.
If no software is installed, press the "Install Software Package" softkey.
The "Select File" window opens and the directory overview of the
system CompactFlash card displayed.
3.
Navigate to the directory where the CD-ROM data was copied, e.g.
System CF-Card/user/sinumerik/SolutionLine.
Position the cursor on the "installer_02_04_01_00.tar.gz" file
MCIS DNC
Installation Manual, 09/2011
11
Installation on SINUMERIK Operate
3.2 Installing the MCIS basis software
4.
Press the "OK" softkey.
You will receive a message about the selected software and its version.
5.
Now press the "OK" softkey to install the package.
- OR Press the "Cancel" softkey if you do not wish to install the selected
installation package.
6.
After the installation has been successfully completed you will receive
an appropriate message.
7.
Press the "OK" softkey to complete the installation.
The installed version is displayed in the "List of Installed Applications"
window.
See also
Installing MCIS applications (Page 13)
MCIS DNC
12
Installation Manual, 09/2011
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
3.3
Installing MCIS applications
Precondition
Once the MCIS basic software has been successfully installed, install the MCIS applications.
See:
Preparing for installation on SINUMERIK Operate (Page 9)
Installing the MCIS basis software (Page 11)
List of the installed applications
The installed versions are displayed in an overview in the "List of Installed Applications"
window.
Column heading
Meaning
Application name
Installed application
Effective version
Current version number
Nominal version
Tick: Indicates that the actual version (effective version = installed
version) matches the required version (nominal version).
Exclamation mark: If the version does not match.
Selecting applications
1.
2.
The "ePS Network Settings" window opens and the activated software
displayed.
Press the "MCIS App Installation" softkey.
The "File Select" window opens and the directory overview is displayed.
MCIS DNC
Installation Manual, 09/2011
13
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
Installing Base Setup
1.
Navigate on the system CompactFlash card to the
user/sinumerik/SolutionLine/dnc2-4-1 directory.
Position the cursor on the "basesetup_02_04_01_00.tar.gz" file.
2.
Press the "OK" softkey.
3.
You will receive the following prompt:
4.
Press the "OK" softkey to confirm your selection.
- OR Press the "Cancel" softkey to prevent the installation of the package.
5.
The installation is started and the procedure is displayed on a progress
bar.
6.
On completion, you receive a success confirmation message.
The installed "Base Setup" applications with version details are
displayed in the following window.
MCIS DNC
14
Installation Manual, 09/2011
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
7.
Press the "OK" softkey.
The "List of Installed Applications" window is displayed and shows you
the applications installed with the associated details.
8.
Restart the controller to activate the application.
1.
Navigate on the system CompactFlash card to the
user/sinumerik/SolutionLine/dnc2-4-1 directory.
Position the cursor on the "MCIS.DNC_02_04_01_00.tar.gz" file.
2.
Press the "OK" softkey.
3.
You will receive the following prompt:
4.
Press the "OK" softkey to confirm your selection.
Installing MCIS DNC
- OR Press the "Cancel" softkey to prevent the installation of the package.
The installation is started and the procedure is displayed on a progress
bar.
MCIS DNC
Installation Manual, 09/2011
15
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
5.
On completion, you receive a success confirmation message.
The installed "DNC" application with version details is displayed in the
following window.
6.
Press the "OK" softkey.
The "List of Installed Applications" window is displayed and shows you
the applications installed with the associated details.
7.
Restart the controller again to activate the applications.
MCIS DNC
16
Installation Manual, 09/2011
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
Displaying details
1.
In the list of installed applications, select the required application.
2.
Press the "Information" softkey in order to view the details of the
corresponding application.
MCIS DNC
Installation Manual, 09/2011
17
Installation on SINUMERIK Operate
3.3 Installing MCIS applications
MCIS DNC
18
Installation Manual, 09/2011
Configuration on SINUMERIK Operate
4.1
4
Configuring URL settings
The client requires three URLs to communicate with the server. You have the option of
customizing the URLs.
Precondition
The applications are installed.
URL settings
Section
Meaning
Directory
The following directories are listed in a selection box:
•
Siemens (data cannot be changed)
•
OEM
•
Addon
•
User
Display homepage
Individual addressing of the homepage.
RenderService
The entry for the Render Service comes from the Siemens directory
and cannot be changed.
See: Operating instructions, eP-Satellite server
Web service URL
Individual address entry of the WebService.
The URL for DNC is that of the DNC MCIS IF server.
Send timeout in ms
Maximum permissible transmission time for sending in milliseconds.
Note:
The entry of the timeout must be greater than 10 ms.
Receive timeout in ms
Maximum permissible transmission time for receiving in milliseconds.
Note:
The entry of the timeout must be greater than 10 ms.
By activating and deactivating the appropriate checkbox, for each setting you can select as
to whether the entry should be overwritten – or not.
MCIS DNC
Installation Manual, 09/2011
19
Configuration on SINUMERIK Operate
4.1 Configuring URL settings
Entering URLs
1.
The "ePS Network Settings" window opens.
Press the "URLs>" softkey.
The current settings are displayed.
2.
Press the "Edit" softkey to change the access data to the ePS Server.
The new entry is accepted if you activate the "Overwrite here"
checkbox.
3.
Press the "OK" softkey.
A syntax check is performed and the access data is saved.
4.
Restart the controller in order that the access data becomes effective.
MCIS DNC
20
Installation Manual, 09/2011
Configuration on SINUMERIK Operate
4.2 Configuring proxy settings
4.2
Configuring proxy settings
You have the option of customizing the proxy settings.
Precondition
The applications are installed.
Proxy settings
Section
Meaning
Proxy settings active
Generally use proxy settings.
Directory
The following directories are listed in a selection box:
•
Siemens (data cannot be changed)
•
OEM
•
Addon
•
User
Automatic
Automatically determine defined proxy settings.
Use proxy script
Use the following proxy settings.
URL (proxy
script)
Use fixed proxy
Proxy 1
Individual addressing of the proxy.
Use the following proxy settings.
Specify up to three proxy settings.
Proxy 2
Proxy 3
Direct
Establish connection without proxy.
By activating and deactivating the appropriate checkbox, for each setting you can select
whether or not the entry should be overwritten.
Entering URLs
1.
The "ePS Network Settings" window opens.
Press the "Proxies>" softkey.
The current settings are displayed.
2.
Press the "Edit" softkey to change the access data to the ePS Server.
If you accept the new entry, then activate the "Overwrite here"
checkbox.
MCIS DNC
Installation Manual, 09/2011
21
Configuration on SINUMERIK Operate
4.2 Configuring proxy settings
3.
Press the "OK" softkey.
A syntax check is performed and the access data is saved.
4.
Restart the controller in order that the access data becomes effective.
Example
Only one script proxy is entered in the user directory and activated for general use.
Additional entries are determined from the other directories.
A detailed description of the proxy server can be found in the following documentation:
References
Configuration Manual: EPS Network Services Configuration, Communication and Data
Concept, Chapter: Proxy server
MCIS DNC
22
Installation Manual, 09/2011
5
Log on user
To obtain access rights of the application, you must log on via the user interface.
Logging on
1.
The "ePS Network Services" window opens.
2.
Press the "User" softkey.
The "Log On to MCIS" window opens.
3.
Enter the following data:
• User name
• Password
• Organization
4.
Press the "Log On" softkey to confirm your entries.
Note:
You will be automatically logged off from the system after 10 hours. A
new logon is required after this time.
MCIS DNC
Installation Manual, 09/2011
23
Log on user
MCIS DNC
24
Installation Manual, 09/2011
6
Synchronizing data
After an installation, it is necessary to initiate a data alignment between the machine and the
server.
Procedure
The "ePS Network Service" window opens.
1.
Press the "Sync" softkey to start the data alignment (synchronization)
between the machine and the server.
2.
On completion, you receive a success confirmation message.
"Synchronization has been initiated successfully".
3.
Press the "OK" softkey.
You return to the "ePS Network Service" window.
MCIS DNC
Installation Manual, 09/2011
25
Synchronizing data
MCIS DNC
26
Installation Manual, 09/2011
Stopping ePS Services
7
When stopping ePS Services on SINUMERIK Operate, the execution of the ePS and MCIS
applications is interrupted.
Procedure
1.
The "ePS Network Settings" window opens and the system status
displayed.
• ePS Services activated
• MCIS activated
2.
Press the "Stop ePS Services" softkey.
The following confirmation prompt appears:
"Do you want to stop ePS Services on this device?"
3.
Press the "OK" softkey to confirm the confirmation prompt.
- OR Press the "Cancel" softkey to stop the process.
4.
After ePS Services has been stopped, you receive the following
message in the "System Status" window:
• EPS Services not activated.
• ePS Services must be started in order to be able to use MCIS
applications.
Note:
If the ePS Services is stopped but MCIS applications are still installed,
SINUMERIK Operate must be restarted after ePS Services has been
started. This makes the installed MCIS applications visible again.
MCIS DNC
Installation Manual, 09/2011
27
Stopping ePS Services
MCIS DNC
28
Installation Manual, 09/2011
Update of MCIS DNC
8
An update of the DNC V 2.4.0 version to the DNC V2.4.1.0 version is not possible.
Procedure
To install a current version, proceed as follows:
1. Uninstall the individual packages, see Stopping ePS Services (Page 27)
2. Then install the new version, see Installation on SINUMERIK Operate (Page 9)
MCIS DNC
Installation Manual, 09/2011
29
Update of MCIS DNC
MCIS DNC
30
Installation Manual, 09/2011
9
Uninstalling DNC
Removing the DNC package
1.
The "ePS Network Services" window is displayed.
2.
Press the "Settings" softkey.
3.
Press the "MCIS App Installation" softkey.
An overview of the installed packages is displayed in the list of installed
applications.
4.
Select the "DNC" package and press the "Uninstall" softkey.
5.
You receive a confirmation prompt whether you really want to remove
the DNC application.
Press the "OK" softkey to remove the package.
The process is displayed in a progress bar.
- OR Press the "Cancel" softkey to prevent the uninstallation.
6.
After the "Uninstallation was successful" message, restart the controller.
Press the "OK" softkey.
Removing the Base package
1.
The "ePS Network Services" window is displayed.
2.
Press the "Settings" softkey.
3.
Press the "MCIS App Installation" softkey.
An overview of the installed packages is displayed in the list of installed
applications.
4.
Now select the "Base" package and press the "Uninstall" softkey.
5.
You receive a confirmation prompt whether you really want to remove
the Base application.
Press the "OK" softkey to remove the package.
The process is displayed in a progress bar.
- OR -
MCIS DNC
Installation Manual, 09/2011
31
Uninstalling DNC
Press the "Cancel" softkey to prevent the uninstallation.
6.
After the "Uninstallation was successful" message, restart the controller.
Press the "OK" softkey.
Removing the Installer package
1.
The "ePS Network Services" window is displayed.
2.
Press the "Settings" softkey.
3.
Press the "MCIS App Installation" softkey.
4.
Select the "Installer" package and press the "Uninstall" softkey.
5.
You receive a confirmation prompt whether you really want to remove
the Installer application.
The most-recently installed application is now displayed in the overview.
Press the "OK" softkey to remove the package.
The process is displayed in a progress bar.
- OR Press the "Cancel" softkey to prevent the uninstallation.
6.
After the "Uninstallation was successful" message, restart the controller.
Press the "OK" softkey.
MCIS Base installation
1.
The "ePS Network Services" window is displayed.
2.
Press the "Settings" softkey.
3.
Press the "MCIS Base Installation" softkey.
The installed version of the MCIS base software is displayed in the
overview.
4.
Press the "Delete SW Package" softkey.
MCIS DNC
32
Installation Manual, 09/2011
Uninstalling DNC
5.
You receive a confirmation prompt whether you want to delete the MCIS
base software installation package 01.02.00.00.000.
Press the "OK" softkey to remove the package.
The process is displayed in a progress bar.
- OR Press the "Cancel" softkey to prevent the uninstallation.
6.
After the "Uninstallation was successful" message, restart the controller.
Press the "OK" softkey.
MCIS DNC
Installation Manual, 09/2011
33
Uninstalling DNC
MCIS DNC
34
Installation Manual, 09/2011