Application Techniques EDS AOP Guidelines for Logix Designer Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation® sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Allen-Bradley, Rockwell Software, Rockwell Automation, RSLogix 5000, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Table of Contents Important User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Chapter 1 Introduction About this publication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Definitions, Acronyms, and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . 4 General EDS file information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 EDS file authoring tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 EDS file installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Icon files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Chapter 2 Creating an EDS file Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Input and Output data structures and parameters . . . . . . . . . . . . . . . . . . . . . 9 Input tags. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Output tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Defining I/O parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Configuration data structures and parameters . . . . . . . . . . . . . . . . . . . . . . 11 Configuration tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Defining configuration parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Using multiple languages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Chapter 3 Module Configuration Dialog Boxes General tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About Module Profile dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Definition dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Info tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internet Protocol tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Configuration tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Diagnostics dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Advanced Network Configuration dialog box. . . . . . . . . . . . . . . . . . . Time Sync tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 18 19 21 22 23 24 24 25 26 26 Chapter 4 EDS File Sections [File] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Revision, CreateDate, CreateTime, ModDate and ModTime keywords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Device] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog and ProdName keywords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 29 29 30 30 30 1 Table of Contents ProdName keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VendName keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ProdTypeStr keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MajRev keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MinRev keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Device Classification] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ClassN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Connection Manager] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ConnectionN keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [ParamClass] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CfgAssembly keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CfgAssemblyExa keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Descriptor keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Assembly] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AssemN/AssemExaN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VariantN/VariantExaN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Params] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ParamN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Groups] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Internationalization] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ProdName keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ParamN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EnumN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GroupN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AssemN/AssemExaN keyword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ConnectionN keyword. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Modular] Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Ethernet Link Class] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [TCP/IP Interface Class] Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [DLR Class] Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [Time Sync Class] Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 33 33 34 34 35 35 35 35 45 45 45 45 45 45 47 47 47 52 52 53 53 53 53 53 53 54 54 55 56 57 Chapter 5 Description of Data Types and Tags Module-Defined Data Type Naming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Tag Naming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Module-Defined Data Type Member Naming . . . . . . . . . . . . . . . . . . . . . . 61 Chapter 6 Example EDS Files Index 2 Minimum EDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enhanced EDS, Single Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enhanced EDS, Single Connection, Configuration Data. . . . . . . . . . . . . Enhanced EDS, Multiple Choice of Connections and Multiple Simultaneous Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 64 65 66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 1 Introduction About this publication Topic Page About this publication 3 General EDS file information 5 The document provides an overview of the Logix Designer EDS Add-On Profile (AOP) feature, how Electronic Data Sheet (EDS) content is used by the feature, and guidelines for creating EDS content that will integrate well within the Logix Designer development environment. The EDS file format for the Common Industrial Protocol (CIP) networks is defined by ODVA. Figure 1 - EDS device in Logix Designer Creating an EDS can be an efficient way to enable a module to operate within the Rockwell integrated architecture, and gives the module developer a better alternative to using the Generic Device AOP. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 3 Chapter 1 Introduction • The Generic Device AOP requires minimal development time because it uses the generic device user interface, but only specifies the basic connection parameters (assembly instance and the size of the Configuration, Input, and Output arrays). The module developer must still create documentation describing the instance values and tag details. It requires the user to manually enter often cryptic configuration parameters. This document describes the specific parts of the EDS file that affect module configuration, I/O, and the user interface in Logix Designer. This document is intended to be used by module developers who intend to have their module configured by the EDS AOP using EDS content. Module developers should: • Be very familiar with the CIP EDS definition; see chapter 7 in THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11 and THE CIP NETWORKS LIBRARY Volume 2, EtherNet/ IP Adaptation of CIP, Edition 1.12. • Be familiar with the Logix Designer dialog boxes. These are described in Module Configuration Dialog Boxes on page 17. • Be familiar with Module-Defined data types generated by AOPs. The Logix Designer EDS AOP feature is limited to devices with a single CIP port that attach to the Ethernet bus. The following devices are not supported: • Devices with one or more CIP ports and a non-CIP backplane • Devices with more than one CIP port • Safety devices References The following documents are referenced in or related to this document. [1] THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11 [2] THE CIP NETWORKS LIBRARY Volume 2, EtherNet/IP Adaptation of CIP, Edition 1.12 Definitions, Acronyms, and Abbreviations The following definitions, acronyms, and abbreviations are used throughout this document. 4 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Introduction Chapter 1 Table 1 - Definitions, Acronyms, and Abbreviations General EDS file information Terms Definition EDS Electronic Data Sheet. A text file that contains configuration data for specific device types. The EDS for a device is provided by the device vendor and is required for compliance with ODVA standards. AOP Add-On Profile. Logix Designer component that can be separately installed and used for configuring one or more modules. EDS AOP EDS Add-On Profile. The Add-On Profile that uses EDS content to construct the profile to support various module types. Profile A subsystem of Logix Designer. Each supported module type has an associated profile. The profile provides information needed to establish topology and module-defined data types, as well as graphical user interface for configuration (in some cases). This section provides general information about EDS tools, EDS installation, and EDS icon files. You can find example EDS files described in Example EDS Files on page 63. EDS file authoring tools EDS files can be created using any ASCII text editor that is capable of handling the character set specified in Section 7-3.5.1 of THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. TIP The use of a specialized EDS editing tool, such as the ODVA freeware tool EZEDS, is recommended. Developers who need to create large families of EDS files of nearly identical modules may choose to use or develop tools that automatically create the EDS files for a set of modules within the product family. If EZ-EDS is not used to construct the file(s), it should be used to verify the EDS file(s) syntax (ODVA uses the latest version during conformance testing). EDS file installation EDS files are provided by the module vendor, and are deployed in one or more ways: • Embedded in the module as described in Section 5-42 (File Object) of THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. • Provided on separate media, such as a CD-ROM. • Downloaded from the module vendor website. EDS files are registered using the EDS Hardware Installation Tool in Logix Designer version 20 or later. There is no need to shut down Logix Designer to Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 5 Chapter 1 Introduction register a new EDS, and the EDS is immediately available. Logix Designer does not allow you to register an older version EDS file over a newer version EDS file. The EDS Hardware Installation Tool issues warnings when it detects problems in the EDS (for example, about discarded entries). IMPORTANT These warnings should be taken into consideration when registering an EDS. For example, a connection may be discarded because an assembly referenced in the connection is missing from the EDS file. If an EDS file is not available for a module that exists in the Logix Designer I/O tree, Logix Designer displays a message that the module is not registered. This can happen when Logix Designer detects a new module, or if you copy a Logix Designer project ACD file to a different computer that does not have the correct EDS files registered. Logix Designer also displays a message if the device configuration was created using a newer version of the EDS than the one registered on the computer. In both cases, Logix Designer cannot display the Module Properties dialog box for the module until you install the correct EDS file. Logix Designer can still download the project to the controller. Icon files TIP Module icon files are highly recommended. If there is no module icon file, Logix Designer assigns a default icon. The icon allows a graphical representation of the module in the RSLinx and Logix Designer environment. Icons can be embedded in modules using the method described in Section 5-42 (File Object) of THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. The EZ-EDS tool version 3.9 or later supports embedding icons inside the EDS file. If icons are embedded inside the EDS using the method described in Section 7-3.6.3 of THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11, they will be extracted automatically from the EDS. Logix Designer can automatically assign icons provided as separate files if their file names match the ones specified by the Icon keyword in the Device Description section ([Device] Section on page 30) of the EDS. The icon files must reside in the same directory as the EDS. If these conditions are not met, the EDS Hardware Installation Tool allows you to manually assign an icon file when registering the EDS. To create icon files, follow the guidelines below: • At a minimum you should create a 32x32 pixel, 16-color icon in the Microsoft format. 6 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Introduction Chapter 1 • For best results, you should define a: • 16x16 16 color icon • 32x32 16 color icon • 48x48 256 color icon All three icons must be stored in one icon file. • You should center your icon in both the horizontal and vertical directions. • You should use transparent pixels for the pixels that are not part of your product. Do not use solid colors for backgrounds. The red dots in the graphic below indicate the points at which your icon should be centered horizontally. This will insure that your icon appears correctly. Figure 2 - Icon horizontal placement In addition, make sure the Logix Designer overlays (for example, inhibited device, error indication) are visible and evident in the Logix Designer I/O tree. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 7 Chapter 1 Introduction Notes: 8 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 2 Creating an EDS file Topic Page Connections 9 Input and Output data structures and parameters 9 Configuration data structures and parameters 11 Using multiple languages 14 This section gives an overview of the process of creating an EDS file for a module. Connections A connection identifies a CIP connection supported by the module and allows for setting some connection parameters that define controller-to-module behavior. There may be different connections for different purposes. For example, one connection could be optimized for speed, and another connection for carrying more data. The connection also defines its Input, Output, and Configuration assemblies (described in Input and Output data structures and parameters on page 9 through Configuration data structures and parameters on page 11). Connections are defined in the [Connection Manager] section of the EDS file (page 35). The connection information appears in the Module Definition dialog box (page 19) and the Connection tab (page 21). Input and Output data structures and parameters This section covers defining your module Input and Output data structures and parameters, and how they are displayed in Logix Designer. In the EDS file, the [Assembly] section defines the data structures. The EDS file details are described later in this document, beginning with EDS File Sections on page 29. The Input and Output data structures define the parameters whose values are produced by the target module and consumed by the target module. • The Input and Output tags are contained in a single non-descriptive array of type SINT, INT, DINT or REAL. • In the EDS file, you can define a detailed assembly or a non-detailed assembly. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 9 Chapter 2 Creating an EDS file • Both detailed and non-detailed assemblies only define the size of the assembly, and result in a non-detailed data type ([Assembly] Section on page 45). Input tags The values for Input tags are sent from the target module to the controller. Figure 3 - Input data structures in Logix Designer Output tags The values for Output tags are sent from the controller to the target module. Figure 4 - Output data structures in Logix Designer Defining I/O parameters You define I/O parameters in the [Params] section of the EDS file (page 47). The following example shows two circled Output parameters (the first bitenumerated). Param2 corresponds to Data[0] and Data[1], Param3 corresponds to Data[2] and Data[3] in Figure 5. 10 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Creating an EDS file Chapter 2 Figure 5 - Output parameters in Logix Designer tags The parameters are included in an assembly in the [Assembly] section: Assem101 = "Output Data", , , 0x0000, ,, ,Param2, $ Output Commands parameter ,Param3; $ Speed Reference parameter … and the parameters are defined in the [Params] section: Param2 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "Output Commands", $ name "", $ units "", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum2 = 0,"Stop", 1,"Run", 2,"Reverse"; Param3 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Speed Reference", $ name "rpm", $ units "", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Configuration data structures and parameters This section covers defining your module configuration data structures and parameters, and how they are displayed in Logix Designer. In the EDS file, the Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 11 Chapter 2 Creating an EDS file [Assembly] section defines the data structures. The EDS file details are described later in this document, beginning with EDS File Sections on page 29. Configuration tags Configuration tags are parameters that are sent from a controller to a target module when an I/O connection is established. They configure and verify how a target module is configured. The configuration data structure defines the configurable parameters for a module. • The configuration tags may include descriptive tag names, as well as individual tag data types that define individual configuration parameters. • In the EDS file, you can define a detailed assembly or a non-detailed assembly. • The detailed assembly results in a detailed data type (this is highly recommended). • The non-detailed assembly only defines the size of the assembly, and results in a non-detailed data type (see [Assembly] in [Assembly] Section on page 45 and [Params] in [Params] Section on page 47). • Type of configuration: – The configuration is delivered using the Forward_Open service in the Data Segment. The configuration data is described by the ConnectionN entry. Figure 6 - Configuration data structures in Logix Designer 12 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Creating an EDS file Chapter 2 Defining configuration parameters You define configuration parameters in the [Params] section of the EDS file. The following example shows two circled configuration items, the first corresponds to Param7 from the EDS snippet below and the second corresponds to Param11 from the EDS snippet below (Param11 is bit enumerated). Figure 7 - Configuration parameters in Logix Designer tags The parameters are included in an assembly in the [Assembly] section: Assem100 = "Configuration Assembly", , , 0x0000, ,, 16,Param7, $ Start Ramp parameter 16,Param8, 2,Param9, $ Selection1 parameter 1,Param10, 5,, 8,Param11; … and the parameters are defined in the [Params] section: Param7 = 0, $ ,, $ 0x0000, $ 0xC7, $ 2, $ "Start Ramp", $ "ms", $ "This is the value 1,10000,1000 $ ,,,, $ ,,,, $ ; $ reserved, shall equal 0 Link Path Size, Link Path Descriptor Data Type Data Size in bytes name units for the start ramp", $ help string min, max, default data values mult, div, base, offset scaling mult, div, base, offset links decimal places Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 13 Chapter 2 Creating an EDS file Parameters can include bit-enumeration: Param11 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD1, $ Data Type 1, $ Data Size in bytes "Bitwise Selection", $ name "", $ units "New Help String", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum11 = 0,"Start", 1,"Stop", 2,"Reserved", 3,"Reserved", 4,"Not to be used", 5,"Not to be used", 6,"Not to be used", 7,"Not to be used"; Using multiple languages It is strongly recommended that you include support for multiple languages in your EDS file. Logix Designer has been translated into English, French, German, Spanish, Portuguese, Italian, Korean, Japanese, and Chinese. Names you can translate include connections, configuration parameters, and assemblies. Tag member names in data structures always use the default string from the original definition in the EDS file. When Logix Designer displays the Module Properties dialog box for a device with an EDS file, these rules control which text is displayed: 1. For non-English languages, Logix Designer automatically uses the translated strings from the [Internationalization] section of the EDS file to match the current language setting. 2. For English, or if there is no matching translated string, then Logix Designer uses the English (“eng”) string from the [Internationalization] section. 3. If there is no English string in the [Internationalization] section, Logix Designer uses the default string from the original definition in the EDS file. [Internationalization] Param7 = { 2, {"eng",0xD0,4,"Start Ramp"}, {"deu",0xD0,4,"Start-Rampe"} }, { 2, {"eng",0xD0,4,"ms"}, 14 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Creating an EDS file Chapter 2 {"deu",0xD0,4,"ms"} }, { 2, {"eng",0xD0,4,"The value for the start ramp"}, {"deu",0xD0,4,"Der Wert für die Start-Rampe"} }; The first group of EDS keywords support internationalization and should always be translated: • ProdName • ConnectionN The second group of EDS keywords support internationalization and need only to be translated if they represent items that appear in the Module Definition dialog box (Figure 11 on page 20) • ParamN • EnumN • GroupN • AssemN, AssemExaN See [Internationalization] Section on page 52 for more information. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 15 Chapter 2 Creating an EDS file Notes: 16 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 3 Module Configuration Dialog Boxes Topic Page General tab 17 Connection tab 21 Module Info tab 22 Internet Protocol tab 23 Port Configuration tab 24 Network tab 25 Time Sync tab 26 Logix Designer uses tabbed dialog boxes with a common look and feel to display the information from an EDS file and from the corresponding module when online. This simplifies device configuration in the integrated architecture. This section lists the dialog boxes, describes their functions, and references the EDS file sections that affect the dialog boxes in Logix Designer. This shows you how the information from the EDS is displayed by the EDS AOP in the Logix Designer user interface. General tab The General tab displays a module’s properties, and allows you to enter some information about the module. This tab is used to configure and display: • Module type and vender name (see ProdTypeStr keyword on page 33. and VendName keyword on page 33). • Name of parent module in the Logix Designer I/O tree. • Name and description of device as it appears in Logix Designer (userconfigurable). • Network addressing (see [Device Classification] Section on page 35 and [Modular] Section on page 54. • Revision, electronic keying information, and connection type (see Module Definition dialog box on page 19). Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 17 Chapter 3 Module Configuration Dialog Boxes Click the module in the Logix Designer I/O tree and press Enter, or right-click the module and select Properties to display this dialog box. Figure 8 - General tab About Module Profile dialog box The About Module Profile dialog box displays version and file information about Logix Designer and the EDS file. In addition, you can view the EDS file in a text editor. This dialog box displays: • Logix Designer Module Profile Core version • Module vendor (see VendName keyword on page 33) • EDS file version, creation date and time, and modification date and time (see Revision, CreateDate, CreateTime, ModDate and ModTime keywords on page 29). Click the icon in the upper-left corner of the Module Properties dialog box to display the context menu, and then select About Module Profile to display this dialog box (see Figure 10). 18 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Module Configuration Dialog Boxes Chapter 3 Figure 9 - About Module Profile dialog box Figure 10 - How to display the About Module Profile dialog box Module Definition dialog box The Module Definition dialog box allows you to configure the module details and the Input/Output data to be transferred. Typically, when defining the properties for a standard module, you can perform the following: • Select the module revision (major and minor, see MajRev keyword on page 34 and MinRev keyword on page 34). Note that the module revision number is not the same as the EDS file version number. • Select the electronic keying option. • Select a single connection that the controller will open (see ConnectionN keyword on page 35). Optionally, for those modules that support one or more additional module definition properties (as defined by the module developer), you can also perform the following: • Configure one or more additional connection settings (for example, remote data, selectable assemblies, configurable sizes, or custom data types). Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 19 Chapter 3 Module Configuration Dialog Boxes • Select multiple, simultaneous connections (for those modules that support them). Click the Change button in the Module Properties dialog box to display this dialog box (see Figure 12). Figure 11 - Module Definition dialog box Figure 12 - How to display the Module Definition dialog box Custom Data Type dialog box The Custom Data Type dialog box allows you to configure indirect Input/ Output parameters. The dialog box displays: • The connection name (see ConnectionN keyword on page 35). • The dynamic I/O module-defined data type information, see T→O and O→T Format fields on page 39 and Indirect Parameter reference under Descriptor field on page 46. Click the Change button in the Module Definition dialog box to display this dialog box. The Change button only appears if indirect parameters exist in Input or Output assemblies associated with the connection (see Figure 14). 20 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Module Configuration Dialog Boxes Chapter 3 Figure 13 - Custom Data Type dialog box Figure 14 - How to display the Custom Data Type dialog box Connection tab The Connection tab displays the set of configured connections (see ConnectionN keyword on page 35) and allows for setting some connection parameters that define controller-to-module behavior. This tab also shows the status of the connection(s) between the controller and the target module. The data on this tab comes directly from the controller. On this tab, you can perform the following: • Select a requested packet interval. • Specify an Input type. • Select an Input trigger. • Choose to inhibit the module. • Configure fault handling and view module faults. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 21 Chapter 3 Module Configuration Dialog Boxes Figure 15 - Connection tab Module Info tab 22 The Module Info tab displays module and status information. It also lets you reset a module to its power-up state. The information on this tab comes directly from the module, and is not displayed if Logix Designer is offline, or if you are currently creating a module. In addition, it indicates if there is a mismatch between the configured module in Logix Designer and the online module. Use this tab to: • Display the module identity, see [Device] Section on page 30. • Display the module status. • Reset the module. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Module Configuration Dialog Boxes Chapter 3 Figure 16 - Module Info tab Internet Protocol tab The Internet Protocol tab displays the TCP/IP object attribute values that exist in the online module and allows the user to make changes to the online module. See [TCP/IP Interface Class] Section on page 55. Figure 17 - Internet Protocol tab Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 23 Chapter 3 Module Configuration Dialog Boxes Port Configuration tab The Port Configuration tab displays the Ethernet Link object attribute values in the online module and allows the user to make changes to the online module. See [Ethernet Link Class] Section on page 54. Figure 18 - Port Configuration tab Click the […] button on the Port Configuration tab to display the Port Diagnostics dialog box (see Figure 19). Port Diagnostics dialog box The Port Diagnostics dialog box displays diagnostic information for the selected port (see Port Configuration tab on page 24). You can also reset the diagnostic counters. Click the […] button on the Port Configuration tab (see Figure 18) to display the Port Diagnostics dialog box. 24 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Module Configuration Dialog Boxes Chapter 3 Figure 19 - Port Diagnostic dialog box Network tab The Network tab displays the Device Level Ring object attribute values in the online module and allows you to make changes to the online module. The Network tab is displayed only for EtherNet/IP modules that support the Device Level Ring object (see [DLR Class] Section on page 56). The tab includes a control to enable Supervisor Mode only if the module supports the Supervisor Mode function. Figure 20 - Network tab Click the Advanced button on the Network tab to display the Advanced Network Configuration dialog box (see Figure 21). Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 25 Chapter 3 Module Configuration Dialog Boxes Advanced Network Configuration dialog box The Advanced Network Configuration dialog box displays the Network Supervisor Mode settings if the module is a Network Supervisor. Click the Advanced button on the Network tab to display the Advanced Network Configuration dialog box (see Figure 20). Figure 21 - Advanced Network Configuration dialog box Time Sync tab 26 The Time Sync tab displays the Time Sync object attribute values in the online module and allows the user to make changes to the online module. The Time Synch tab is only displayed for modules that support the Time Sync object (see [Time Sync Class] Section on page 57). Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Module Configuration Dialog Boxes Chapter 3 Figure 22 - Time Sync tab Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 27 Chapter 3 Module Configuration Dialog Boxes Notes: 28 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 4 EDS File Sections Topic Page [File] Section 29 [Device] Section 30 [Device Classification] Section 35 [Connection Manager] Section 35 [ParamClass] Section 45 [Assembly] Section 45 [Params] Section 47 [Internationalization] Section 52 [Ethernet Link Class] Section 54 [TCP/IP Interface Class] Section 55 [DLR Class] Section 56 [Time Sync Class] Section 57 This section describes the EDS sections and entry keywords used by the Logix Designer EDS AOP feature. It covers how the keyword affects a CIP service (for example, the Forward_Open service) or affects a Module Properties dialog box. There are several example EDS files described in Example EDS Files on page 63. EDS sections and keywords that are not mentioned in this document are not supported in the Logix Designer EDS AOP and are ignored. [File] Section [File] DescText = "Test EDS Description"; CreateDate = 01-14-2011; CreateTime = 14:26:47; ModDate = 12-23-2011; ModTime = 11:55:27; Revision = 1.0; Revision, CreateDate, CreateTime, ModDate and ModTime keywords The revision, creation, and modification information are displayed on the About dialog box. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 29 Chapter 4 EDS File Sections Figure 23 - Revision, Create and Modification on the “About” dialog box [Device] Section [Device] VendCode = 2011; VendName = "Test Vendor 2011"; ProdType = 0xFFFF; ProdTypeStr = "Generic Device"; ProdCode = 9; MajRev = 1; MinRev = 1; ProdName = "3 Assemblies with Structure"; Catalog = "TestDevice#9"; Catalog and ProdName keywords The Catalog string, followed by the ProdName string, are concatenated for display on the General Tab, Type field (Figure 8 on page 18). If the optional Catalog keyword is not present, the value of the ProdName keyword is displayed alone). TIP The combination of the strings for Catalog and ProdName should be unique for all modules from a vendor so that they can be distinguished from each other. Catalog keyword The Catalog keyword value is displayed in the Catalog Number column of the Catalog and Favorites tabs of the Select Module Type dialog box. If the optional Catalog keyword is omitted, a string of the form xxxx_yyyy_zzzz (xxxx is hex VendCode, yyyy is hex ProdType, zzzz is hex ProdCode) is displayed instead. 30 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 Figure 24 - Catalog string on Select Module Type dialog box IMPORTANT Module developers should include the Catalog keyword. The Catalog keyword should not contain spaces, because space characters cause problems with the Path control on the Communication tab of the Message Configuration dialog box (the Message Configuration dialog box is invoked from the MSG instruction). The Catalog keyword is included in Catalog Organizer, Data Types tree, ModuleDefined data type name. Alpha-numeric characters and the underscore (_) character should be used. Other characters are removed, except dash (-), which is converted to underscore (_). The Catalog keyword value is displayed in the I/O Configuration tree module entry in Controller Organizer. Figure 25 - Catalog string in I/O Configuration tree Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 31 Chapter 4 EDS File Sections ProdName keyword The ProdName keyword value is displayed in the Description column of the Catalog and Favorites tab of the Select Module Type dialog box. Figure 26 - ProdName string on Catalog tab of Select Module Type dialog box The ProdName keyword value is displayed in the Modules column on the Module Discovery tab of the Select Module Type dialog box. Figure 27 - ProdName string on Module Discovery tab of Select Module Type dialog box 32 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 VendName keyword If an ODVA-defined vendor string is not known for the VendCode, the VendName from the first EDS file registered for the VendCode is used; otherwise, the ODVA-defined vendor string is used. IMPORTANT There is no mechanism to change VendName once it has been set by registering the first EDS file with that VendName. The VendName keyword value is displayed on the General Tab in the Vendor field. Figure 28 - Vendor string on General tab The VendName keyword value is displayed in the Vendor column on the Catalog and Favorites tabs of the Select Module Type dialog box. Figure 29 - Vendor string on Select Module Type dialog box ProdTypeStr keyword The ProdTypeStr keyword value is displayed in the Category column of the Catalog and Favorites tab of the Select Module Type dialog box. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 33 Chapter 4 EDS File Sections Figure 30 - ProdTypeStr string on Select Module Type dialog box If an ODVA-defined profile string is not known for publicly defined ProdType values, the ProdTypeStr from the first EDS registered for the ProdType is used; otherwise, the ODVA-defined profile name is used, see THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11, table 67.1. For vendor-specific ProdType values, the ProdTypeStr from the first EDS registered for the VendCode/ProdType is used. IMPORTANT There is no mechanism to change ProdTypeStr once it has been set by registering the first EDS with that ProdTypeStr. MajRev keyword The MajRev keyword value is available for selection on the Major Revision control of the Module Definition dialog box (Figure 11 on page 20). MinRev keyword The MinRev value is used as the default value of Minor Revision control on the Module Definition dialog box (Figure 11 on page 20). 34 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections [Device Classification] Section Chapter 4 [Device Classification] Class1 = EtherNetIP; ClassN keyword If the module is an EtherNet/IP module, a ClassN keyword must exist in the [Device Classification] section. An example of the keyword will look as follows: Class1 = EtherNetIP; [Connection Manager] Section [Connection Manager] Connection1 = 0x04030002, 0x44640405, Param1,,Assem101, Param1,,Assem102, ,, ,Assem100, "I/O Connection", "", "20 04 24 64 2C 65 2C 66"; $ $ $ $ $ $ $ O−>T RPI, size, format T−>O RPI, size, format proxy config size, format target config size, format Connection Name help string Path Extra comment lines have been removed from this example. ConnectionN keyword The ConnectionN keyword identifies a CIP connection supported by the module. Connections are added by default if no variables exist in the Path field and the connection does not conflict with an existing connection (see Path field on page 46, for rules describing connections that can exist together). All ExclusiveOwner connections are added, and then Input-Only connections are added, and then Listen-Only connections are added. ConnectionN entries that do not meet the criteria listed below in this section are ignored. TIP A “Ping” ConnectionN entry is also supported; see Section 7-3.6.10.1.13 in THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. A Ping Connection allows a Module to be added with no connections configured. The controller will periodically send a Null Forward_Open service as described in Section 3-5.5.2.2.2 in THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11 to verify the correct module is present. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 35 Chapter 4 EDS File Sections ConnectionN fields Trigger and Transport field • Transport class Must indicate Class 1 support (may indicate others). The Transport Class field value of the Transport Class and Trigger parameter sent in the Forward_Open request is always set to 1. • Trigger The Trigger is displayed on the Input Trigger column of the Connection tab of the Modules Properties dialog box. The trigger (Cyclic, Change of State, or Application) is selected by a list control. Figure 31 - Connection Input Trigger selection The user-selected Input Trigger value is the Forward_Open Transport Class and Trigger parameter. • Application type Must indicate one of Listen-Only, Input-Only or Exclusive-Owner. Redundant-Owner is not supported. • Direction The Direction value is the Forward_Open Transport Class and Trigger parameter, Dir field value. This is to be set to Client. Connection Parameters field • T→O and O→T fixed/variable size supported The T→O and O→T fixed/variable size supported value must indicate fixed size. Fixed is the Forward_Open T→O and O→T Network Connection parameters, Fixed/Variable field values. 36 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 • O→T Real time transfer format Must indicate one of: – Connection is pure data and modeless – the controller will not include a 32 bit run/idle header – Heartbeat – no application data – 32 bit run/idle header – the controller will include a 32 bit run/idle header. • T→O Real time transfer format Must indicate one of: – Connection is pure data and modeless – a 32 bit run/idle header will not be included in the Input Module-Defined data type/tag definition – Heartbeat – no application data – 32 bit run/idle header – a 32 bit run/idle header will be included in the Input Module-Defined data type or tag definition. • O→T Connection type Must indicate POINT2POINT, may also specify NULL. Point to Point is the Forward_Open O→T Network Connection parameter, Connection Type field value. • T→O Connection type The T→O Connection type must indicate POINT2POINT or MULTICAST; the T→O Connection type may indicate all connection type values (POINT2POINT, MULTICAST and NULL). Figure 32 - Connection Input Type selection The T→O Connection type is displayed in the Input Type column of the Connection tab. The T→O Connection type (Unicast or Multicast) is selected by a drop-down control. The user selection of Point to Point or Multicast is the Forward_Open T→O Network Connection parameter, Connection Type field value. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 37 Chapter 4 EDS File Sections • T→O and O→T Connection types The module can be reconfigured by a NULL Forward_Open service (while the I/O connection is open) if the following conditions are true: – Both T→O and O→T NULL connection types are indicated. – The Write Allowed bit group in the configuration assembly descriptor has a value of 0 (assembly may or may not be written when I/O connection is open) or the Write Allowed bit group in the configuration assembly descriptor has a value of 1 (assembly can be written when any I/O connection is open). A NULL Forward_Open service is sent when a MSG instruction, Module Reconfiguration Message Type is executed. • T→O and O→T Priority The T→O and O→T Priority must indicate either both T→O and O→T HIGH priority or both T→O and O→T SCHEDULED priority. Both HIGH and SCHEDULED can be indicated. High or Scheduled (Scheduled if both are specified) is the Forward_Open T→O and O→T Network Connection parameters, Priority field values. T→O and O→T RPI fields • If both fields are empty, the default RPI for the bus type will be selected and the default range for the bus type will be enabled. For Ethernet bus – minimum RPI is 1.0ms, maximum RPI is 3200.0ms, and default RPI is 20.0ms. If a UDINT value or ParamN is specified, the intersection of the T→O and O→T value(s) and bus minimum and maximum values are used to generate the minimum and maximum RPI values. If no intersection exists, no RPI value can be chosen and as a consequence, the connection cannot be added via EDS AOP. IMPORTANT Enumerated ParamNs are not supported for RPIs. The RPI is displayed in the RPI column on the Connection tab (page 21). Figure 33 - Connection RPI selection 38 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 The user selected RPI value is the Forward_Open T→O and O→T RPI parameter values. TIP If the O→T production is heartbeat, then a longer O→T RPI value is calculated and used to reduce unneeded traffic. T→O and O→T Size fields If the size field is empty, the size of the item specified in the corresponding format field size plus sequence count size (2) and optional 32 bit run/idle header size (4) is the Forward_Open T→O and O→T Network Connection parameter, Connection Size values. If the size field is a UINT, then the size field value plus sequence count size(2) and optional 32 bit run/idle header size (4) is the Forward_Open T→O and O→T Network Connection parameter, Connection Size values. The T→O and O→T Size is displayed on Module Definition dialog box, Size column. Figure 34 - Module Definition size selection If the size field is a ParamN, then the user selected size plus sequence count size(2) and optional 32 bit run/idle header size (4) are the Forward_Open T→O and O→T Network Connection parameter, Connection Size values. If the size field is a parameter, either range or enumeration can be supported, but not both. T→O and O→T Format fields If the format field is empty, no Input or Output Module-Defined data type or tag is created. IMPORTANT If you want Input/Output Module-Defined data types and tags to be created, you must specify the format field even when the format of the data is dynamic. In this case, an AssemN must be specified as the format with the Allow Value Edit bit of the Descriptor of this AssemN set and the size of the AssemN must be specified by the AssemN Size field or a single Member Size/Member Reference pair with an empty Member Reference field. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 39 Chapter 4 EDS File Sections If the format specifies one or more ParamN entries., a Module-Defined data type and tag is created if the format results in one or more ParamNs. IMPORTANT The Input Module-Defined data types created for T→O will include a BOOL member named ConnectionFaulted in the first 32 bits. The Input Module-Defined data type created for T→O will include a BOOL member named RunMode in the first 32 bits if the T→O Real Time transfer format is 32-bit run/idle header. The Module-Defined data types created have a data member of type SINT, INT, DINT or REAL array as chosen by the user in the Module Definition dialog box, Size column. The type choice of INT will only be allowed when the I/O sizes (in bytes) is divisible by 2. The type choices of DINT and REAL are allowed when the I/O sizes (in bytes) are divisible by 4. If the size fields are ParamNs, then the maximum values of the ParamN are used to determine if INT, DINT and REAL choices are available. If the maximum values are divisible by 2, the choice of SINT and INT are available. If the maximum values are divisible by 4 then the choices of SINT, INT, DINT and REAL are available. Proxy Config Size and Format fields If not empty, the connection will be ignored. Target Config Size field If the size field is empty, the size of the item specified in the corresponding format field size is the Forward_Open Connection_Path parameter data segment size value (converted from bytes to words and rounded up). If the size field is a UINT, then the size field will be the Forward_Open Connection_Path parameter data segment size value (converted from bytes to words and rounded up). If the size field is a ParamN, the default value of the ParamN will be the Forward_Open Connection_Path parameter data segment size value (converted from bytes to words and rounded up). Target Config Format field If the format field is empty and the Target Config Size field contains a non-null size, the Forward_Open Connection_Path parameter data segment will be filled with zeros. If the format field is a ParamN or AssemN, the value of the ParamN or AssemN will be the Forward_Open Connection_Path parameter data segment data values. If the format specifies one or more ParamN entries, a Module-Defined data type and tag is created if the format results in one or more ParamNs. 40 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 Some configuration parameters are not included in the configuration ModuleDefined data type and tag. The parameters not included are: • I/O assembly variant selectors – if a configuration parameter is an I/O variant selector, the variant selections are displayed on the Module Definition dialog box, Assembly column. Figure 35 - Variant I/O assemblies on Module Definition dialog box • I/O assembly variant selectors – if a configuration parameter is an I/O variant selector, the variant selections are displayed on the Connections control in the Module Definition group on the General Tab. Figure 36 - Variant I/O assemblies in Module Definition group box • Indirect I/O parameter – if a configuration parameter is an indirect I/O parameter, the pointed to name is displayed on the Custom Data Type dialog box (launched from Module Definition dialog box). Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 41 Chapter 4 EDS File Sections Figure 37 - Indirect I/O parameters on Custom Data Type dialog box • I/O size parameter – if a configuration parameter is used to specify a variable I/O size, it is displayed on the Module Definition dialog box, Size column. Figure 38 - I/O size parameters on Custom Data Type dialog box Connection Name String field The Connection Name String is displayed on the Connections control in the Module Definition group on the General Tab. 42 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 Figure 39 - Connection Name in Module Definition group The Connection Name string is displayed on the Connections grid of the Connection tab. Figure 40 - Connection Name on Connection tab The Connection Name string is displayed on Connections grid of the Module Definition dialog box. Figure 41 - Connection Name on Module Definition dialog box TIP It is recommended to limit name strings to 22 characters to allow display of the chosen connection name without resizing the dialog box. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 43 Chapter 4 EDS File Sections Help String field Ignored. Path field The ConnectionN path field is the part of the Forward_Open Connection_Path parameter immediately prior to the data segment (if a data segment exists) or at the end of the Connection_Path parameter (if the data segment does not exist). If multiple connections exist with the same connection path, only the ConnectionN entry with the lowest N will be available in the EDS AOP. All other connections with identical paths are discarded during the EDS install process. This is indicated as a warning when using the EDS Hardware Installation Tool to register the EDS file (EDS file installation on page 5). If two connections are to be available that are identical except for their configuration (one with configuration, one without), they must have different paths; it is recommended that the connection without configuration does not include a configuration path. The Path field contains up to 3 application paths. These 3 application paths are used to limit the set of connections that can be configured simultaneously. IMPORTANT If the module has additional rules that limit the set of connections that can be opened simultaneously, the module developer must document these rules for the user. Configuration application path If a configured ConnectionN entry includes non-empty Target Config size/format fields, then all other ConnectionN entries, which include a different Configuration application path and non-empty Target Config size/format fields, are not available to be added. Originator to Target application path If a configured ConnectionN entry specifies an O→T Real time transfer format that is not heartbeat, then all other ConnectionN entries, which include the same Originator to Target application path, are not available to be added. Target to Originator application path If a configured ConnectionN entry specifies a T→O Real time transfer format that is not heartbeat, then all other ConnectionN entries, which include the same Target to Originator application path, are not available to be added. 44 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 The ConnectionN Path field can contain variables ([ParamN] entries) in the O→T and T→O application path. When the connection is configured in the Logix Designer Module Definition dialog box, the user can set the ParamN value in the Remote Data column. The ConnectionN path field can contain symbols (ANSI_SYMBOL entries) in the O→T and T→O application path. When the connection is configured in the Logix Designer Module Definition dialog box, the user can set the tag value in the Remote Data column. [ParamClass] Section CfgAssembly keyword Ignored CfgAssemblyExa keyword Ignored Descriptor keyword Ignored. [Assembly] Section AssemN/AssemExaN keyword Supported uses • ConnectionN O→T Format – see ConnectionN keyword on page 35. • ConnectionN T→O Format – see ConnectionN keyword on page 35. • ConnectionN Target Config Format – see ConnectionN keyword on page 35. Nested assemblies Assemblies can be nested. The result of nested assemblies will always be flat; no nested structures will be displayed. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 45 Chapter 4 EDS File Sections AssemN/AssemExaN fields Name field If this AssemN/AssemExaN is specified as a VariantExaN Selection Entry for a variant specified for a ConnectionN T→O or O→T Format, then the name is displayed on the Module Definition dialog box, Assembly column. If this AssemN/AssemExaN is specified as a VariantExaN Selection Entry for a variant specified for a ConnectionN T→O or O→T Format, then the name is displayed on the General Tab, Module Definition group, Connections control. Path field Ignored Size field The Size field defines the size of the Assembly. The Size field can be empty if the Member Size/Member Reference is provided for all members. Descriptor field • Allow Value Edit bit field If this AssemN/AssemExaN is specified as the ConnectionN T→O or O→T Format and all AssemN/AssemExaN Member Reference fields are empty, then the Module-Defined data type created will have a single data member of type SINT, INT, DINT, or REAL array as chosen by the user in the Module Definition dialog box. If this AssemN/AssemExaN is specified as the ConnectionN Target Config Format and all AssemN/AssemExaN Member Reference fields are empty, then the Module-Defined data type created will have a single data member of type SINT if the Allow Value Edit bit is set; otherwise this data member is hidden. • Assem Type bit field Not supported. • Not Addressable bit field Not supported. • Write Allowed bit field If this AssemN/AssemExaN is specified as the ConnectionN Target Config Format and the Write Allowed value is either 0 (write with I/O connection may be allowed) or 1 (write with I/O connection is allowed) 46 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 and the ConnectionN specifies a NULL Connection Type for both O→T and T→O, then: • A NULL forward open will be sent to the module when a MSG instruction that specifies the Reconfigure option, with this module as the target. • Indirect Parameter Handling bit field If this AssemN/AssemExaN is specified as the ConnectionN T→O or O→T Format and indirect parameters exist in this AssemN/AssemExaN, this value must be set to 0 (treat indirect parameters as indirect parameter). If this AssemN/AssemExaN is specified as the ConnectionN Target Config Format and indirect parameters exist in this AssemN/AssemExaN, this value must be set to 1 (treat indirect parameters as direct parameter). Member Size field No EDS AOP specific handling. Member Reference field If this AssemN/AssemExaN is specified as the ConnectionN Target Config Format, then this member is included in the configuration Module-Defined data type. If this AssemN/AssemExaN is specified as the ConnectionN T→O or O→T Format, then the size of this member is included in the Input/ Output Module-Defined data type array size. VariantN/VariantExaN keyword The Variant/VariantExaN keywords are supported as defined in the CIP Common specification, see THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. The supported uses of the Variant/VariantExaN keywords are listed in the description of the referencing keyword. See [Connection Manager] Section on page 35, ConnectionN keyword and Target Config Format field description. See also [Assembly] Section on page 45, AssemN/AssemExaN keyword, Name field description. [Params] Section ParamN keyword Input/Output/Configuration details uses • ConnectionN O→T Format – see ConnectionN keyword on page 35. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 47 Chapter 4 EDS File Sections • ConnectionN T→O Format – see ConnectionN keyword on page 35. • ConnectionN Target Config Format – see ConnectionN keyword on page 35. The ParamN name should follow Module-Defined data type member name naming conventions, see Parameter Name field on page 50. ParamN fields Link Path field Ignored. Descriptor field • Supports settable path Ignored. • Get_Enumerated_String Supported Ignored. Enumerations are supported as described in other parts of this TIP document without this bit being set. • Supports Scaling Ignored. • Supports Scaling Links Ignored. • Read Only Parameter If the parameter described by the ParamN entry is included in the module configuration, it will be hidden in the Configuration module-defined data type. • Monitor Parameter Ignored. • Supports Extended Precision Ignored. • Supports non-consecutive enumerated strings Ignored. • Allows both enumeration and min/max range values Ignored. • Non-displayed parameter If set, ParamN is not displayed. • Indirect Parameter reference If set and the ParamN is in a Configuration assembly, it is presented on the Module Definition, Custom Data type dialog box. If the ParamN is in an Input or Output assembly, the selected ParamN (from the Module Definition, Custom Data type dialog box) is used as the Module-Defined data type member. 48 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 • Not Addressable Ignored. • Save Supported Ignored. • Apply Supported Ignored. • Write Only Parameter Ignored. Data Type field STIME, DATE_AND_TIME, STRING2, LTIME, STRINGN, TIME, EPATH, ENGUNIT, and STRINGI types are not supported. The ParamN entry is discarded and any keyword that specifies the ParamN entry as a field value is discarded. If ParamN is in a Configuration assembly, the data type determines the ModuleDefined data type member type: • CIP BOOL type results in controller BOOL type. • CIP SINT type results in controller SINT type. • CIP INT type results in controller INT type. • CIP DINT type results in controller DINT type. • CIP LINT type results in 2 controller DINT types. • CIP USINT type results in controller SINT type.(1) • CIP UINT type results in controller INT type. (2) • CIP UDINT type results in controller DINT type. (3) • • • • • • • • • • • CIP ULINT type results in 2 controller DINT types.(4) CIP REAL type results in controller REAL type. CIP LREAL type results in 64 controller BOOL types. CIP DATE type results in controller INT type. CIP TIME_OF_DAY type results in controller DINT type. CIP STRING type results in array of controller SINT type. Note that the length member will be hidden. CIP BYTE type results in controller SINT type. CIP WORD type results in controller INT type. CIP DWORD type results in controller DINT type. CIP LWORD type results in 2 controller DINT types. CIP FTIME type results in controller DINT type. (1) If the maximum value of the unsigned 8-bit integer is 128 or larger, the entire Module-Defined data type will be a SINT array. (2) If the maximum value of the unsigned 16-bit integer is 32768 or larger, the entire Module-Defined data type will be a SINT array. (3) If the maximum value of the unsigned 32-bit integer is 2147483648 or larger, the entire Module-Defined data type will be a SINT array. (4) If the maximum unsigned ULINT value would result in a negative LINT value, the entire Module-Defined data type becomes a SINT array. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 49 Chapter 4 EDS File Sections • CIP ITIME type results in controller INT type. • CIP SHORT_STRING type results in array of controller SINT type. Note that the length member will be hidden. Data Size field Follows the CIP specification. See THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. Parameter Name field If the ParamN is a member of a Configuration assembly, the Parameter Name is used as the Module-Defined data type member name. The Parameter Name is converted to conform to the IEC 61131 name standard (alpha-numeric character or underscore(_) character). All unsupported characters, including spaces, are replaced with an underscore (_) character during the conversion, consecutive underscore (_) characters and trailing underscore(_) characters are removed and leading numbers are prefixed with an underscore character. Parameter Names should not include underscore and space characters. These guidelines should be followed for Parameter Names that are included in Configuration assemblies: • Member names should be as short as practical. Users don’t want to type ConfigDataBits when Data will suffice. Note that the user can infer much from the context. Data appearing in an Input data type is obviously Input data. Data from a discrete module is almost always represented as a bit. The goal for Module-Defined data type member names is 15 characters or less. • The first letter in each word making up the name should be capitalized. This allows the words to stand out when the data type name is compressed (after spaces are removed.) • Naming should be consistent. Refer to existing data types as a guide as opposed to getting creative. • Naming should not be redundant. • Names should not reflect the data type. • Naming of BOOLEAN members should be for the positive sense of the member. Note that this requires the proper design of the device. Note also that the on state is not necessarily the most interesting state. • Channel data is prefixed (not post fixed) with Ch followed by the channel number. It is not spelled out, since it has become a common convention. • In cases where it is desirable to have individual homogeneous bits named (vs. indexed through a Data array), the individual bits should be prefixed (not post fixed) with Pt followed by the 2 digit point number. 50 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 Units String field Ignored Help String field Ignored Minimum Value field Ignored if the parameter is part of a Configuration assembly. If used in the Module Definition dialog box, this field represents the minimum value that the user can choose. Maximum Value field If in a Configuration assembly, used to determine if a parameter can be properly represented. If used in the Module Definition dialog box, this field represents the maximum value that can be chosen. Default Value field Used as defined in the CIP specification. See THE CIP NETWORKS LIBRARY Volume 1, Common Industrial Protocol (CIP™), Edition 3.11. Scaling (Multiplier, Divider, Base and Offset) fields Ignored Link (Multiplier, Divider, Base and Offset) fields Ignored Decimal Precision field Ignored International Parameter Name field Ignored International Engineering Units field Ignored International Help String field Ignored Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 51 Chapter 4 EDS File Sections ParamN enumeration, EnumN If the EnumN is for a bit string (BYTE, WORD, DWORD, LWORD) ParamN that is a member of a configuration assembly, then the bit name is used as the Module-Defined data type member name. The bit name is converted to conform to the IEC 61131 name standard. All unsupported characters, including spaces, are replaced with an underscore (_) character during the conversion, consecutive underscore (_) characters and trailing underscore (_) characters are removed and leading numbers are prefixed with an underscore (_) character. These guidelines should be followed for bit names that are included in Configuration assemblies: • Bit names should be as short as practical • The first letter in each word making up the name should be capitalized. This allows the words to stand out when the data type name is compressed (after spaces are removed). • Naming should be consistent (for example, Data and Status). If two different modules return status, both should probably be named Status. Refer to existing data types as a guide as opposed to getting creative. • Naming should not be redundant. For example, O.On instead of O.OutputOn. • Names should not reflect the data type. For example, On, not OnBit. • Naming of bits should be for the positive sense of the member. FuseBlown is 1 when the fuse is blown, 0 when it is not. It is generally preferable to name a bit member in a manner that reflects the interesting state rather than the steady state value. In most cases, this is the on, enabled, or energized state versus the off state. For example, FuseBlown is preferable to FuseOK or FuseNotBlown. Note that this requires the proper design of the device. Note also that the on state is not necessarily the most interesting state. [Groups] Section Ignored [Internationalization] Section The language Logix Designer is displaying determines which string from the EDS file is used for the items below. If a string for the Logix Designer language is not specified, then the string from the non-Internationalization section version of the keyword is used. TIP 52 The keywords listed below should have English, French, German, Spanish, Portuguese, Italian, Korean, Japanese, and Chinese strings because Logix Designer is translated to each of these languages. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections Chapter 4 ProdName keyword If this ProdName is defined, it is used instead of the ProdName specified in the [Device] section. ParamN keyword Ignored International Parameter Name field Ignored International Engineering Units field Ignored International Help String field Ignored EnumN keyword Ignored GroupN keyword Ignored AssemN/AssemExaN keyword Used only for assemblies selected by I/O variants. If the Internationalized Assembly Name String is defined, it is used instead of the name defined in the [Assembly] section in all cases. ConnectionN keyword If the Internationalized Connection Name String is defined, it is used instead of the name defined in the [Connection Manager] section in all cases. The Internationalized Connection Help String is not used. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 53 Chapter 4 EDS File Sections [Modular] Section Ignored. [Ethernet Link Class] Section If the module supports the Ethernet Link object this section should exist. IMPORTANT If the module has more than one Ethernet port, this shall be reflected in the EDS as specified in the ODVA specifications. The following entry keywords should be defined: • Number_Of_Static_Instances • MaxInst • Either • InterfaceLabelN • [Params] section ParamN entries with Path value of 20 F6 24 NN 30 0A where NN is the Ethernet Link object instance. The default value of this ParamN should be the interface label string. TIP If no interface label is specified, a default label is displayed, the instance value. The Port Configuration tab display is affected by these items. The optional or conditional Ethernet Link object Interface Counters and Media Counters attributes should be implemented. Figure 42 - Port Configuration tab 54 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections [TCP/IP Interface Class] Section Chapter 4 If the module supports the TCP/IP Interface object, this section should exist. The following entry keywords should be defined: • [Params] section ParamN entry with Path value of 20 F5 24 01 30 02. The default value of this ParamN should represent the TCP/IP object capabilities for this module. TIP If no capability ParamN entry exists, the value of 0 is used for the TCP/ IP capabilities attribute. The Internet Protocol tab is affected by this item. Figure 43 - Internet Protocol tab Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 55 Chapter 4 EDS File Sections [DLR Class] Section The following entry keywords should be defined: • [Assembly] section AssemN entry with Path value of 20 47 24 01 30 04. • The AssemN entry should include the Member References for each member of the Ring Supervisor Config attribute. The ParamN that represents the Beacon Interval member should specify the minimum and maximum values supported for this module’s Beacon Interval. • If no Ring Supervisor Config AssemN entry exists, 400 microseconds is used as the minimum Beacon Interval and 100,000 microseconds is used as the maximum Beacon Interval. • Ring_Supervisor_Capable The Network tab is displayed if this section exists. Figure 44 - Network tab 56 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 EDS File Sections [Time Sync Class] Section Chapter 4 If the module supports the Time Sync object, this section should exist. The Time Sync tab is displayed if this section exists. Figure 45 - Time Sync tab Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 57 Chapter 4 EDS File Sections Notes: 58 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 5 Description of Data Types and Tags Topic Page Module-Defined Data Type Naming 59 Tag Naming 60 Module-Defined Data Type Member Naming 61 This section describes the rules the EDS AOP follows for creating ModuleDefined Configuration, Input, and Output data type names, tag names, and Module-Defined data type member names. Module-Defined Data Type Naming Module-defined data types define the structure of the data used by the module for its Input, Output, and/or Configuration Data. These tags allow you to access this data via the controller’s program. This section describes the rules Logix Designer uses for naming module-defined data types. The names are displayed under Data Types in the Controller Organizer. Figure 46 - Module-Defined Data Type Names Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 59 Chapter 5 Description of Data Types and Tags A C/I/O Module Defined data type name is constructed from: <Vendor>:<Catalog_Number>_<CRC>:<Tag_Type>:<Version> • Vendor code: the 4-digit hex value assigned by ODVA. • Catalog_Number String value: The Catalog_Number String comes from the Catalog string from the EDS file. Dash (-) characters are converted to underscore (_) characters and all non-IEC-61131 characters are removed. If no Catalog string exists in the EDS file the 4 digit hex ProdType and 4 digit hex ProdCode are used separated by an underscore (_) character (for example: 0002_0006). The Catalog_Number string is truncated to limit the Module-Defined data type name length to 40 characters. • CRC String value: Generated from the Module-Defined data type contents, the details of this algorithm will not be provided. • Tag_Type String value: • C • I • O • Version String value: Always 0 Tag Naming Figure 47 - Tag Names • Name on the Module Properties General tab is used: • <Name>:<I or O>[<Ordinal>] • <Name>:C • The ordinal comes from the Module Definition dialog box, Tag Suffix column. Ordinal only exists when more than one connection can be configured. 60 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Description of Data Types and Tags Chapter 5 Figure 48 - Module Definition, Tag Suffix column Module-Defined Data Type Member Naming • Member names are truncated to 40 characters. • Duplicate member names are made unique by appending an ordinal suffix. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 61 Chapter 5 Description of Data Types and Tags Notes: 62 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Chapter 6 Example EDS Files The following sections describe examples of EDS files and how these EDS files translate into details in Logix Designer. TIP Minimum EDS The example EDS files are attached to this PDF file. In Adobe Acrobat. or Adobe Reader, you display the Attachments panel by: • Clicking the small paperclip icon in the bottom left corner of the Acrobat or Reader window. • Selecting the View > Navigation Panels > Attachments command to display the Attachments panel. This section describes the bare bones minimum that is required to make an EDS usable in an Logix Designer environment, plus a number of extensions that improve its usability. The Minimal EDS described in this section makes use of the Allow Value Edit bit while the more complex EDS files described later use parameters to structure the assemblies. It is strongly suggested that you add more details to an EDS as outlined in the more detailed EDS files below. The Minimal EDS is shown here mainly for reference and to break the evolution of an EDS into several steps. With the Minimal EDS, the Logix Designer EDS AOP offers only the following choices and structures. • Choice of IP address. • Selection of Unicast and Multicast data production where appropriate and offered by the EDS. • Selection of Cyclic or Change-of-State trigger if offered by the EDS. • Creation of an Input tag (for an Exclusive-Owner Connection, an InputOnly Connection, or a Listen-Only Connection) and possibly an Output tag (only for an Exclusive-Owner Connection), depending on what is offered in the EDS. • Choice of SINT, INT, DINT, or REAL data structure for the I/O tags. This sample EDS actually contains only an entry for an Exclusive-Owner Connection. See the attached Minimal EDS.eds file for details. Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 63 Chapter 6 Example EDS Files This EDS creates nothing but an Input data tag and an Output data tag of the defined sizes. In particular, no structure or meaning of the I/O data is visible. Logix Designer adds a status bit to the Input tag that reports when the connection has failed. This is what the resulting tags look like with data type SINT: Figure 49 - I/O tags for minimum EDS Enhanced EDS, Single Connection To provide a better user experience, at least the following enhancements are recommended: • Range limitation for RPI See the attached One Connection, IO Assemblies with Structures EDS.eds file for details. The EDS file includes six parameters and two assemblies. • Param1 limits the RPI range to values between 4.0 and 100.0ms with a default value of 10.0ms 64 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Example EDS Files Chapter 6 This is what this module looks like in Logix Designer: Figure 50 - I/O tags for enhanced EDS Enhanced EDS, Single Connection, Configuration Data This EDS includes a configuration assembly structured into individual parameters in addition to the features of the previous EDS. See the attached One Connection, 3 Assemblies with Structures EDS.eds file for details. There are now a total of 11 parameters and the additional parameters 7 through 11 describe the structure of the Configuration Assembly. This is what this module looks like in the Logix Designer tag structure: Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 65 Chapter 6 Example EDS Files Figure 51 - I/O and Configuration tags for enhanced EDS Enhanced EDS, Multiple Choice of Connections and Multiple Simultaneous Connections An EDS file may define multiple ConnectionN entries for a module. There are typically a set of up to three ConnectionN entries describing one or more connections: • An Exclusive-Owner Connection (if the module has Output data). • An Input-Only Connection. • A Listen-Only Connection. Such a set of ConnectionN entries specify the same Input Connection Point and (if included) the same configuration data. Multiple sets like this may exist that describe connections using different I/O Assemblies. See the attached Multiple Connections 3 Assemblies with Structures EDS.eds file for details. With an EDS like this, the Module Definition dialog box allows the user to pick one of the connections. The first Exclusive-Owner Connection in the EDS is presented as default connection. 66 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Example EDS Files Chapter 6 Figure 52 - Module Definition Dialog box and connection selection If Logix Designer determines that there are multiple sets of ConnectionN entries, a group of connections is created. Figure 53 - Module Definition Dialog box with multiple connection configuration Once a member of a group of connections has been chosen, further connections can only be selected from ConnectionN entries outside that group. Figure 54 - Module Definition Dialog box with multiple connections configured Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 67 Chapter 6 Example EDS Files The tags created by multiple connections have numbers appended to make them unambiguous. 68 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Index Custom Data Type dialog box 20 D A abbreviations 4 About Module Profile dialog box 18 about this publication 3 acronyms 4 Advanced Network Configuration dialog box 26 AOP definition 5 Generic Device 3 [Assembly] section 45 Configuration parameters 13 Input and Output parameters 11 AssemN/AssemExaN keyword 45, 53 Descriptor field 46 Name field 46 Path field 46 Size field 46 B bit-enumerated parameters 10, 14 buses, supported 4 C Catalog keyword 30 CfgAssembly keyword 45 CfgAssemblyExa keyword 45 CIP connections 9 ClassN keyword 35 Configuration data structure 12 parameters 12, 13 tags 12 conformance testing 5 [Connection Manager] section 35 Connection Name String field 42 Connection Parameters field 36 Connection tab 21 ConnectionN keyword 35, 53 Connection Name String field 42 Connection Parameters field 36 Help String field 44 Path field 44 Proxy Config Size and Format fields 40 T−>O and O−>T Format fields 39 T−>O and O−>T RPI fields 38 T−>O and O−>T Size fields 39 Target Config Format field 40 Target Config Size field 40 Trigger and Transport fields 36 CreateDate keyword 29 CreateTime keyword 29 creating EDS files 3 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 data structures Configuration 12 Input 9 Output 9 definitions AOP 5 EDS 5 EDS AOP 5 profile 5 deploying EDS files 5 Descriptor field 46 Descriptor keyword 45 [Device] section 30 [Device Classification] section 35 devices not supported 4 supported 4 [DLR Class] section 56 E editing EDS files 5 EDS AOP definition 5 feature limitations 4 EDS file sections [Assembly] 45 [Connection Manager] 35 [Device Classification] 35 [Device] 30 [DLR Class] 56 [Ethernet Link Class] 54 [File] 29 [Groups] 52 [Internationalization] 52 [Modular] 54 [ParamClass] 45 [Params] 47 [TCP/IP Interface Class] 55 [Time Sync Class] 57 EDS files and Logix Designer 4 creating 3 deploying 5 editing 5 Enhanced EDS, multiple connections 66 Enhanced EDS, single connection 64 Enhanced EDS, single connection, config data 65 examples 63 general information 5 icon files 6 internationalization 14 Minimum EDS 63 not available 6 registering 5 requirements for module developers 4 EDS Hardware Installation Tool registering EDS files 5 warnings 6 EDS, definition 5 69 Index Enhanced EDS, multiple connections file example 66 Enhanced EDS, single connection file example 64 Enhanced EDS, single connection, config data file example 65 enumeration EnumN 52 parameter 10 parameters 13 ParamN 52 EnumN enumeration 52 EnumN keyword 53 [Ethernet Link Class] section 54 example EDS files 63 Enhanced EDS, single connection 64, 66 Enhanced EDS, single connection, config data 65 Minimum EDS 63 EZ-EDS authoring tool 5 F fields Data Size 50 Data Type 49 Decimal Precision 51 Default Value 51 Descriptor 48 Help String 51 International Engineering Units 51, 53 International Help String 51, 53 International Parameter Name 51, 53 Link (Multiplier, Divider, Base and Offset) 51 Link Path 48 Maximum Value 51 Minimum Value 51 Parameter Name 50 Scaling (Multiplier, Divider, Base and Offset) 51 Units String 51 [File] section 29 G general information, EDS files 5 General tab 17 Generic Device AOP 3 GroupN keyword 53 [Groups] section 52 H Help String field 44 I icon files guidelines 6 Logix Designer 7 70 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 icon files for EDS files 6 Input data structures 9 parameters 10 tags 10 installing EDS files See registering EDS files [Internationalization] section 52 internationalization EDS files 14 keywords 15 Internet Protocol tab 23 K keywords AssemN/AssemExaN 45, 53 Catalog 30 CfgAssembly 45 CfgAssemblyExa 45 ClassN 35 ConnectionN 35, 53 CreateDate 29 CreateTime 29 Descriptor 45 EnumN 53 GroupN 53 MajRev 34 MinRev 34 ModDate 29 ModTime 29 ParamN 47, 53 ProdName 30, 32, 53 ProdTypeStr 33 Revision 29 VariantN/VariantExaN 47 VendName 33 L limitations of EDS AOP feature 4 literature, related 4 Logix Designer About Module Profile dialog box 18 Advanced Network Configuration dialog box 26 and EDS files 4 Connection tab 21 Custom Data Type dialog box 20 EDS Hardware Installation Tool 5 EDS icon files 7 General tab 17 Internet Protocol tab 23 Module Definition dialog box 19 Module Info tab 22 Network tab 25 Port Configuration tab 24 Port Diagnostics dialog box 24 Time Sync tab 26 M MajRev keyword 34 Index Minimum EDS file example 63 MinRev keyword 34 ModDate and ModTime keywords 29 [Modular] section 54 Module Definition dialog box 19 module developers, requirements 4 Module Info tab 22 module-defined data types member naming 61 naming 59 multiple languages See internationialization N Name field 46 naming module-defined data type members 61 module-defined data types 59 Network tab 25 [Params] section 47 configuration parameters 13 Input and Output parameters 11 Path field 44, 46 Port Configuration tab 24 Port Diagnostics dialog box 24 ProdName keyword 30, 32, 53 ProdTypeStr keyword 33 profile, definition 5 Proxy Config Size and Format fields 40 R references 4 registering EDS files 5 related literature 4 requirements for module developers 4 Revision keyword 29 S O ODVA conformance testing 5 EZ-EDS authoring tool 5 Output data structues 9 parameters 10 tags 10 P [ParamClass] section 45 parameters bit-enumerated 10, 14 Configuration 12, 13 Input 10 Output 10 ParamN enumeration 52 ParamN keyword 47, 53 Data Size field 50 Data Type field 49 Decimal Precision field 51 Default Value field 51 Descriptor field 48 Help String field 51 International Engineering Units field 51, 53 International Help String field 51, 53 International Parameter Name field 51, 53 Link (Multiplier, Divider, Base and Offset) fields 51 Link Path field 48 Maximum Value field 51 Minimum Value field 51 Parameter Name field 50 Scaling (Multiplier, Divider, Base and Offset) fields 51 Units String field 51 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 sample EDS files See example EDS files Size field 46 supported devices and buses 4 T T−>O and O−>T Format fields 39 T−>O and O−>T RPI fields 38 T−>O and O−>T Size fields 39 tags Configuration 12 Input 10 Output 10 Target Config Format field 40 Target Config Size field 40 [TCP/IP Interface Class] section 55 [Time Sync Class] section 57 Time Sync tab 26 translation See internationalization Transport field 36 Trigger field 36 U unsupported devices 4 V VariantN/VariantExaN keywords 47 VendName keyword 33 71 Index 72 Rockwell Automation Publication 1756-CO003A-EN-E - April 2012 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support, you can find technical manuals, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. You can also visit our Knowledgebase at http://www.rockwellautomation.com/knowledgebase for FAQs, technical information, support chat and forums, software updates, and to sign up for product notification updates. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnectSM support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/support/. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/support/americas/phone_en.html, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Outside United States Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. Publication 1756-CO003A-EN-E - April 2012 Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.