a ® Model ZW109BP Pressure Reducing Valve with Low Flow By-Pass company SPECIFICATION SUBMITTAL SHEET APPLICATION SIZES GLOBE: Threaded ends 2" thru 3” Flanged ends 2" thru 4” ANGLE: Threaded ends 2” thru 3” Flanged ends 2" thru 4” Ductile Iron 150 Class, 250 psi max. TEMPERATURE RATING: water 33°F to 180°F BY-PASS and PILOT SPRING RANGE: 15-150 psi FEATURES Epoxy coated, FDA approved Pilot Assembly Flow clean strainer (sizes 2”-3”) ”Y” type strainer (sizes 4”) Opening speed control (sizes 2”-3”) Isolation Valve (sizes 4”) Low flow by-pass valve uses 1/2” NR3 (sizes 2”, 2 1/2” & 3), 3/4” NR3 (size 4”) MAIN VALVE OPTIONS ____ Size ____ Y - 300lb. class flange (400 psi max.) ____ TH - Threaded ends (400 psi max.) ____ KB - Viton rubber ____ SS - Stainless Steel Seat ____ AN - Angle body ____ D - Check valve in Pilot DIMENSIONS DIM ANSI CLASS A Threaded AA 150 AAA 300 B Diameter C Max. D Threaded DD 150 DDD 300 E ALL F 150 FF 300 G Threaded (flanged 4") GG 150 GGG 300 H NPT Body Tapping J NPT Cover Center Plug K NPT Cover Tapping Valve Stem Internal Thread UNF Stem Travel Approx. Wt. Lbs. Page 1 of 2 The Wilkins ZW109BP Pressure Reducing Valve with Low Flow By-Pass automatically reduces a higher inlet pressure to a steady lower downstream pressure regardless of changing flow rate. To be installed in a distribution system where the demand varies over a wide range. This frequently occurs in industrial, residential, educational, high-rise buildings and other applications. Another important feature of the valve is its space efficient configuration, allowing easy installation and maintenance. MATERIALS Main Valve Body Main Valve Bonnet Disc Guide Seat Disc Diaphragm Stem Spring Ductile Iron ASTM A536 Ductile Iron ASTM A536 Bronze ASTM B 62 Bronze ASTM B 62 Buna-N Rubber Nylon reinforced Buna-N Stainless Steel Stainless Steel B (DIAMETER) J K OUTLET INLET E FF F Valve SIZE inches 2 9 3/8 9 3/8 10 6 5/8 6 1/2 4 3/4 4 3/4 5 1 1/2 3 3 1/4 3 1/4 3 1/4 3 1/2 3/8 1/2 3/8 10-32 0.6 35 2 1/2 11 11 11 5/8 8 7 9/16 5 1/2 5 1/2 5 7/8 1 11/16 3 1/2 3 3/4 4 4 4 5/16 1/2 1/2 1/2 10-32 0.7 50 3 12 1/2 12 13 1/4 9 1/8 8 3/16 6 1/4 6 6 3/8 2 1/16 3 3/4 4 1/8 4 1/2 4 4 3/8 1/2 1/2 1/2 1/4-28 0.8 70 4 15 15 5/8 11 1/2 10 5/8 7 1/2 7 7/8 3 3/16 4 1/2 5 5 5 5/16 3/4 3/4 3/4 1/4-28 1.1 140 C AA AAA A H B (DIAMETER) J K C OUTLET GGG GG G INLET H D DD DDD DOCUMENT #: REVISION: REG-ZW109BP 1/10 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com PILOT SYSTEM DIMENSIONS X inches 2 2 1/2 3 4 mm 50 65 80 100 X Max. (inches) 12 1/2 12 3/4 13 13 1/4 Y Max. (inches) 4 7 8 9 Z Max. (inches) 6 1/2 8 9 10 Valve Size Y INLET GLOBE Z X Y ANGLE Z INLET OPERATION The Model ZW109BP utilizes a pressure reducing pilot valve that installs on the discharge side of the control circuitry. The pilot is a direct acting, normally open, spring loaded, diaphragm actuated valve; the spring being adjustable within a 10:1 ratio. The operation of the ZW109BP begins with accurately sizing the valve, then fine tuning the control circuit by adjusting the NR3 pilot spring to the desired downstream pressure. It is hydraulically operated and controlled by a NR3 pilot control, which senses pressure at the main valve outlet. An increase in outlet pressure opens the control. This causes the main valve cover pressure to vary, modulating the main valve and thereby maintaining constant outlet pressure. The Model NR3 low flow pressure reducing by-pass is preset to a higher pressure than the pilot control. The NR3 responds to pressure changes from the main valve outlet. When the pilot control closes, the Model NR3 by-pass valve remains open allowing water to flow through, by-pass closes when the flow decreases and the downstream pressure reaches its set point. FLOW CHARACTERISTICS Valve Size Suggested ZW109BP Flow (GPM) *Standard ZW109 Suggested Flow (Liters/sec) *Suggested extra By-pass *Minimum Flow Rate Range inches mm Max. Continuous Max. Intermittent Min. Continuous Min. Continuous Max. Continuous Max. Intermittent Min. Continuous Valve sizes Extra By-pass & ZW109BP 2 50 210 260 1-10 15 13 16.4 0.9 2 1/2 65 300 370 1-10 20 19 23 0.32 3 80 460 580 1-10 30 29 37 0.32 4 100 800 990 1-20 50 50 62 0.63 1" 500 1-1/4" 500 1-1/2" 500 2" 500 1 - 15 1 to 20 1 to 30 1 to 50 *Adding an extra By-Pass Valve widens the minimum flow range of the ZW109BP to match the Minimum Continuous flow of the standard ZW109. OUTLET PRESSURE GAUGE INLET PRESSURE GAUGE TYPICAL INSTALLATION Contact the Zurn/Wilkins factory for additional By-pass recommendations based on your unique flow applications. OUTLET SHUT-OFF INLET SHUT-OFF DIRECTION OF FLOW The ZW109BP is not a substitute for a flow By-Pass in all cases. The valve is commonly used in buildings where 1-15 GPM low flows are common in off peak usage. Many Factors should be considered in sizing a pressure reducing valve: inlet pressure, outlet pressure and flow rates. The sizing of additional low flow by-pass valves are based on a minimum of a 50 psi differential between the inlet and set outlet pressure. To develop a smooth seamless flow response it may be necessary to add an additional low flow by-pass valve to the ZW109BP installation to compensate for a range of anticipated flows below the minimum continuous flow rate. To control the opening point of the additional by-pass valves, set the valve you want to open first 5psi higher in static downstream set pressure. NR3 SPECIFICATIONS The Pressure Reducing Valve shall be a single seated, line pressure operated, diaphragm actuated, pilot controlled, globe or angle valve. The valve shall seal by means of a corrosion-resistant seat and resilient, rectangular seat disc. These and other parts shall be replaceable in the field; all such service and adjustments to be possible without removing the valve from the line. The main valve body shall be ductile iron ASTM A 536. The stem of the basic valve shall be guided top and bottom by integral bushings. The basic valve and its pilot control system shall contain no packing glands or stuffing boxes. The diaphragm shall not be used as a seating surface nor shall pistons be used as an operating medium. All internal and external ferrous surfaces shall be coated with a high quality, fusion epoxy coating. The NR3 pilot control system shall consist of a two-way, normally open, direct acting, adjustable spring loaded, diaphragm actuated pressure reducing pilot. The pilot control shall be field adjustable from 15 psi to 150 psi; adjustment range not to exceed a 10:1 ratio. The valve shall include a NR3 Pressure Reducing By-Pass Valve. The Pressure Reducing Valve shall be a WILKINS Model ZW109BP. JOB NAME CONTRACTOR JOB LOCATION ENGINEER WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com Page 2 of 2