GigaBit LX to TX Tap
Get total traffic visibility for monitoring and security devices by placing Net Optics
GigaBit LX to TX Taps on critical network links. GigaBit LX to TX Taps support
passive monitoring of GigaBit links at speeds at 1000 Mbps.
Technical Specifications:
Splitter:
Split Ratio: 50/50,
60/40, 70/30
Fiber Type: Corning Singlemode 8.5/125µm
For superior reliability, the GigaBit LX to TX Tap features Link Fault Signaling which
gives the devices connected to the Tap critical information about link status. If
either side of the bi-directional link fails, the Tap immediately communicates the
fault to both devices.
Wave Length: 1310nm
The GibaBit LX to TX Taps establish permanent passive access ports without
introducing a point of failure or disturbing other network connections. Without an IP
address, monitoring devices are isolated from the network, dramatically reducing
their exposure to attacks. However, the monitoring device connected to the Tap still
sees all full-duplex traffic, including Layer 1 and Layer 2 errors.
Storage Temperature: -10ºC to 70ºC
For extra uptime protection, Net Optics GigaBit LX to TX Taps offer redundant
power connections. Should the primary power source fail, the Tap automatically
switches to the backup power source. Full-duplex monitoring is a snap with
supplied cables. All network and monitoring cables necessary for plug-and-play
deployment are included.
Passive, Secure Technology
• Provides passive access at speeds at 1000 Mbps without data stream
interference or introducing a point of failure
• Link Fault Signaling prevents undetected link failures
• Permanent in-line installation without affecting network performance
• Passes all full-duplex traffic (including errors) from all layers for comprehensive
troubleshooting
• No IP address is needed for the Tap or monitoring device, enhancing monitoring
security
• Redundant power ensures monitoring uptime
Ease of Use
•
•
•
•
•
LED indicators show redundant power and link status
Front-mounted connectors make installation and operation quick and easy
Silk-screened application diagram illustrates all connections for easy deployment
Optional 19-inch rack frames hold up to 3 or 12 Taps
Tested and compatible with all major manufacturers’ monitoring devices,
including protocol analyzers, probes, and intrusion detection/prevention systems
Max Insertion Loss: Network Port: 3.7dB, 2.8dB, 2.0dB
Operating:
Operating Temperature: 0ºC to 40ºC
Relative Humidity: 10% min, 95% max, non-condensing
Mechanical:
Power Supply:
Input: 100-240V, 0.5A, 47-63Hz, Output: 12V 1.5A
Dimensions: 1.125” high x 6.5” deep x 4.5” wide
Fiber Optic Interface:
Connector: Class I, eye-safe, laser emitter type. These Class
I Lasers conform to the applicable requirements per US 21 CFR
(J) and EN 60825-1, also UL 1950 applications.
Optical Transmitter Wave Length: 1310nm nominal
Output Power: -10 dB min, -3 dB max
Optical Reciever Input Sensitivityr:
-3 dB min, -20 dB max
Cable Interface:
Copper Cable Type:
22-24 AWG unshielded twisted pair cable, CAT5/CAT5e
Link Distance Supported: 100 meters
Connectors:
Monitoring Ports: (2) RJ45, 8-pin connectors
Network Ports: (2) Singlemode Duplex LC connectors
Certifications:
Fully RoHS compliant
Part Number
Description
CVT-LX5/GCU
CVT-LX4/GCU
CVT-LX3/GCU
RK-12V2
RK-3V2
GigaBit LX to TX Tap, 50/50
GigaBit LX to TX Tap, 60/40
GigaBit LX to TX Tap, 70/30
Twelve-Slot Rackmount Frame
Three-Slot Rackmount Frame
All products include a 1 year manufacturer’s warranty. An additional 1
or 2 year extended warranty may also be purchased.
5303 Betsy Ross Drive • Santa Clara, CA 95054
Tel: +1 (408) 737-7777 • www.netoptics.com
Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All
rights reserved. Additional company and product names may be trademarks or registered trademarks
of the individual companies and are respectfully acknowledged.
PUBCVTLXTXD Rev. 1, 06/06
GigaBit SX to TX Tap
Net Optics GigaBit SX to TX Tap simplifies connecting GigaBit copper monitoring
and security devices to SX fiber network links. Convert SX to TX and tap into the
link with one device, reducing cost and complexity at the same time.GigaBit SX to
TX Taps support passive monitoring of GigaBit links at speeds at 1000 Mbps.
The GibaBit SX to TX Taps establish permanent passive access ports without
introducing a point of failure or disturbing other network connections.
Without an IP address, monitoring devices are isolated from the network,
dramatically reducing their exposure to attacks. However, the monitoring device
connected to the Tap still sees all full-duplex traffic, including Layer 1 and Layer 2
errors.
For extra uptime protection, Net Optics GigaBit SX to TX Taps offer redundant
power connections. Should the primary power source fail, the Tap automatically
switches to the backup power source. Full-duplex monitoring is a snap with
supplied cables. All network and monitoring cables necessary for plug-and-play
deployment are included.
Passive, Secure Technology
• Provides passive access at speeds at 1000 Mbps without data stream
interference or introducing a point of failure
• Access SX links with GigaBit copper devices without a separate converter
• Permanent in-line installation without affecting network performance
• Passes all full-duplex traffic (including errors) from all layers for comprehensive
troubleshooting
• No IP address is needed for the Tap or monitoring device, enhancing monitoring
security
• Redundant power ensures monitoring uptime
Ease of Use
•
•
•
•
•
•
LED indicators show redundant power and link status
Front-mounted connectors make installation and operation quick and easy
Connectors are perfectly angled to reduce cable strain
Silk-screened application diagram illustrates all connections for easy deployment
Optional 19-inch rack frames hold up to 3 or 12 Taps
Tested and compatible with all major manufacturers’ monitoring devices,
including protocol analyzers, probes, and intrusion detection/prevention systems
Certifications:
Fully RoHS compliant
Technical Specifications:
Splitter Specifications:
Split Ratio: 50/50,
60/40, 70/30
Fiber Type: Corning Multimode 62.5/125µm
Wave Length: 850nm
Insertion Loss: Network Port: 4.5dB
Operating Specifications:
Operating Temperature: 0ºC to 40ºC
Storage Temperature: -10ºC to 70ºC
Relative Humidity: 10% min, 95% max, non-condensing
Mechanical Specifications:
Power Supply:
Input: 100-240V, 0.5A, 47-63Hz, Output: 12V 1.5A
-48V DC typical, -36V DC min, -75V DC max
Dimensions: 1.125” high x 6.5” deep x 4.5” wide
Fiber Optic Interface:
Connector: Class I, eye-safe, laser emitter type. These Class
I Lasers conform to the applicable requirements per US 21 CFR
(J) and EN 60825-1, also UL 1950 applications.
Optical Transmitter Wave Length: 850nm nominal
Output Power: -9.5 dB min, -4 dB max
Optical Reciever Input Sensitivity:
0 dB min, -17 dB max
Cable Interface:
Copper Cable Type:
22-24 AWG unshielded twisted pair cable, CAT5/CAT5e
Link Distance Supported: 100 meters
Connectors:
Monitoring Ports: (2) RJ45, 8-pin connectors
Network Ports: (2) Multimode Duplex LC connectors
Part Number
Description
CVT-SXn*/GCU
CVT-SXn*/GCU-48V
RK-12V2
RK-3V2
GigaBit SX to TX Tap
GigaBit SX to TX Tap -48V DC
Twelve-Slot Rackmount Frame
Three-Slot Rackmount Frame
* “n” is the split ratio where 5 is 50/50, 4 is 60/40, and 3 is
70/30. All products include a 1 year manufacturer’s warranty. An
additional 1 or 2 year extended warranty may also be purchased.
5303 Betsy Ross Drive • Santa Clara, CA 95054
Tel: +1 (408) 737-7777 • www.netoptics.com
Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All
rights reserved. Additional company and product names may be trademarks or registered trademarks
of the individual companies and are respectfully acknowledged. PUBCVTGSXTXD Rev. 1, 06/06