TDS 10 (Euro)DOCSIS cable modem TDS 10 with extension modules For remote meter monitoring and reading • Low additional costs • Easy installation of units • 30 individual meters can be read with one device • Monitoring of data transfer 99811859_EN.indd 1 22.03.2012 14:23:24 DOCSIS/EuroDOCSIS cable modem with M-Bus for smart metering The TDS 10 from Kathrein is a DOCSIS/EuroDOCSIS 2.0-compliant cable modem for installation rail mounting. It is designed to transmit data for remote meter reading. The TDS 10 automatically identifies if the protocol is DOCSIS or EuroDOCSIS allowing easy commissioning without requiring manual intervention. The design has been specially optimised for installation in meter cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. The TDS 10 features an M-Bus master and is equipped with three M-Bus clamps which allow connection of up to 30 M-Bus clients (slaves). The clients are fed through the M-Bus; polarity is not to be taken into account when they are connected. The M-Bus is a robust two-wire bus designed for remote reading of the following reader types: - Heat meters - Water meters - Electricity meters - Gas meters Remote meter reading over an existing cable network Ethernet interface (local service interface) Three M-Bus interfaces in compliance with EN 13757, with screw terminals Connection of up to 30 meters Integrated M-Bus master Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Automatic switch-over to DOCSIS or EuroDOCSIS Easy installation on installation rails Easy registration onto DOCSIS or EuroDOCSIS CMTS without requiring any special hardware/software settings Integrated 230 VAC power supply with screw terminals (L, N, PE) Internal Web server for configuration of the Ethernet interface (address: port: 192.168.100.1:81) The M-Bus can be designed as a tree or star structure. Normal telephone cables or category 5 cables can be used as cabling. M-Bus data transport: The headend queries meter data over the TDS 10 on TCP-Port 3007. The cable modem transacts the commands and the corresponding M-Bus protocol to the M-Bus over the serial interface. The received M-Bus data from the addressed meter is then transmitted back to the headend over the Ethernet interface (TCP) without interpretation by the TDS 10. In co-operation with the respective providers, this new modem opens the doors to totally new business models for cable operators. The TDS 10 M-Bus cable modem in use NE 4 M-Bus Power Plant Management HFC-Netz mit EuroDOCSIS CMTS Internet Internet VPN 99811859_EN.indd 2 22.03.2012 14:23:34 Technical data Type TDS 10 Order no. 26210221 Receiver (downstream) Modulation 64/256 QAM Symbol rate DOCSIS MSym/s 5.057 (64 QAM)/5.361 (256 QAM) Symbol rate EuroDOCSIS MSym/s 6.952 (64 QAM)/6.952 (256 QAM) Frequency range MHz 90 to 862 Channel bandwidth DOCSIS/EuroDOCSIS MHz 6/8 Input level range dBμV 49 to 79 Input impedance Ω 75 Modulation TDMA QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM Symbol rate kSym/s 160, 320, 640, 1,280, 2,560 Transmitter (upstream) Frequency range MHz 5 to 65 Channel bandwidth kHz 200, 400, 800, 1,600, 3,200, 6,400 Output level range dBμV 68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM), 68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA) Output impedance Ω 75 Network characteristics MAC protocol EuroDOCSIS 2.0/MCNS DOCSIS 2.0 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Management Safety Baseline Privacy/Baseline Privacy Plus Data filtering 32 Unicast addresses Connections To CATV network F-type socket To service PC RJ 45-10/100 BaseT (half/full duplex, auto-sensing) VDC Three parallel-connected screw terminal pairs M-Bus idle mode, logical “1” VDC 36 M-Bus active mode, logical “0” VDC 22 Baud 2,400 m 100 M-Bus interface Max. number of M-Bus clients, 1.5 mA each Default baud rate (configurable via SNMP-OID) Max. bus length (JYSTY 2*0.8²) 30 Voltage supply Supply voltage Screw terminals (L, N, PE) VAC 230 W 8.3 Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range °C -5 to +50 Weight g Approx. 300 Nominal input voltage Power consumption (30 M-Bus clients connected) General Protection class IP 20 Housing material PC and ABS Flammability rating UL-94 standard All data are typical values unless stated otherwise. 99811859_EN.indd 3 22.03.2012 14:23:40 M-Bus Ethernet converter for TDS 10 TDA 10-CS TDA 10-232 26210694 26210700 TDA 10-CS, similar to picture The TDA 10-CS from Kathrein is an interface converter for bidirectional conversion of the M-Bus protocol into CS-Bus protocol and vice-versa. The Kathrein TDA 10-232 is an interface converter for bidirectional conversion of the M-Bus protocol into RS 232 protocol and vice-versa. The TDA 10-232 interface converter types are designed for interface conversion, extend the connection options of the TDS 10 on other interfaces beyond the M-Bus and are constructed for installation rail mounting. Different TDA 10 interface converter types can be connected to an M-Bus so that various interfaces can be operated with a TDS 10. When connecting the interface modules, observe the number of load units (M-Bus clients) that are limited by current drain. A TDS 10 can feed up to 30 load units. Remote meter reading over an existing cable network in conjunction with the TDS 10 Powering over M-Bus connection Easy installation on installation rails Available types: TDA 10-CS: Conversion of M-Bus protocol into CS-Bus protocol with independent data rates TDA 10-232: Conversion of the M-Bus protocol into the RS 232 protocol with independent data rates The interface modules EuroDOCSIS/HFC network M-Bus 230 VAC 99811859_EN.indd 4 CS-Bus RS 232 22.03.2012 14:23:44 Technical data Tec Type Orde no. Order TDA 10-CS TDA 10-232 26210694 26210700 Conn Connections Inter Interface 1 Baud rate (default value = 2400 baud) M-Bus, one screw terminal pair Baud 2,400 ... 9,600 Inter Interface 2 CS bus RS 232 interface (eHz) Baud 300 ... 9,600 300 ... 9,600 Level for idle mode (logical “1”) mA 17 - Level for active mode (logical “0”) mA 4 - kByte 6 6 (3 for Push operation) Baud rate (default value = 2,400 or 9,600 baud) Max. reception data buffer CS voltage V 14 - Over the M-Bus Over the M-Bus 15 10 Load units on M-Bus 10 7 Number of slaves on interface 2 ≤3 1 Voltage supply Current drain from the M-Bus (for an M-Bus voltage of 36 V) mA General Dimensions (W x H x D) mm 25 x 90 x 60 Operating temperature range °C -5 to +50 LED signalling Operational voltage All data are typical values unless stated otherwise. Ethernet interface with an M-Bus interface for Smart Metering TDS 10-Eth The TDS 10-Eth from Kathrein is an Ethernet M-Bus interface with an integrated M-Bus master for installation rail mounting. It is designed to transmit M-Bus data over Ethernet data networks. The design has been specially optimised for installation in installation cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. the serial interface. ce. The received M-Bus M data from the addressed meter is then transmitted back to the headend over the Ethernet interface (TCP) without interpretation by the TDS 10-Eth. Remote transmission of M-Bus data over Ethernet data networks Ethernet interface (RJ 45) Three M-Bus interfaces in compliance with EN 13757, with screw terminals The M-Bus is a robust two-wire bus designed for the transmission of various different measurement values and can be arranged as a tree or star structure. As a two-wire bus normal telephone cable or category 5 cable can be used. Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, RS 232-MIB Integrated 230 VAC power supply with screw terminals (L, N, PE) M-Bus data transport: The headend queries meter data over the TDS 10-Eth on TCP-Port 3007. The TDS 10-Eth transacts the commands and the corresponding M-Bus protocol to the M-Bus over Easy installation on installation rails Internal Web server for configuration of the Ethernet interface (address: port: 192.168.100.1:81) The TDS 10-Eth features an M-Bus master and is equipped with three M-Bus clamps which allow connection of up to 30 M-Bus clients (meters or slaves). The clients are fed through the M-Bus; polarity is not to be taken into account when they are connected. 99811859_EN.indd 5 22.03.2012 14:23:57 The interface modules M-Bus M Ethernet CS-Bus 230 VAC RS 232 36 V 24 V -12 V Technical data Type TDS 10-Eth Order no. 26210702 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http Management SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Baseline Privacy Interface MIB Safety Baseline Privacy/Baseline Privacy Plus Data filtering 32 Unicast addresses Connections Data network RJ 45-10/100 BaseT (half/full duplex, auto-sensing) M-Bus interface Three parallel-connected screw terminal pairs M-Bus idle mode, logical “1” VDC 36 M-Bus active mode, logical “0” VDC 22 Number of clients supplied (< 1.5 mA per client) Default baud rate (configurable via SNMP-OID) Max. bus length (JYSTY 2*0,8²) 30 Baud 2,400 m 100 Voltage supply Supply voltage Screw terminals (L, N, PE) VAC 230 W 8.3 Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range °C -5 to +50 Weight g 270 Nominal input voltage Power consumption (30 M-Bus clients connected) General Protection class IP 20 Housing material PC and ABS Flammability rating UL-94 standard All data are typical values unless stated otherwise. 99811859_EN.indd 6 22.03.2012 14:24:27 DOCSIS/EuroDOCSIS cable modem with four 65 VAC monitoring inputs TDS 10-PWR The TDS 10-PWR from Kathrein is a DOCSIS/EuroDOCSIS 2.0-compliant cable modem for installation rail mounting. It is designed to transmit data during the monitoring of up to four remote-feed power supplies (65 VAC). Voltages are measured cyclically and can be read out. If voltages fall below a user-defined alarm threshold, an alarm will go off. Different correction factors for various curve forms (sine, trapezium, rectangle, etc.) can be entered into the MIB for correct display of voltages. The TDS 10-PWR automatically identifies if the protocol is DOCSIS or EuroDOCSIS allowing easy commissioning without requiring manual intervention. The design has been specially optimised for installation in installation cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. Remote reading of four AC voltage values over the existing cable network Ethernet interface (local service interface) Connection of up to four power supply lines using screw terminals (USV) with 65 VAC Easyy registration onto DOCSIS DOCS or EuroDOCSIS CMTS without requiring any special hardware/software settings Integrated 230 VAC power supply with screw terminals (L, N, PE) Easy installation on installation rails LEDs for: Downstream carrier search, modem ready for data traffic, Ethernet connection ok, measurement size alarm Measurement of up to four AC voltage signals (polling, cycle time < 5 seconds) Display of measured values in Kathrein-MIB with integration of SCTE-HMS-MIB for alarm thresholds The measured value is the rectified mean, using the correction factor for a sine wave (default). Many other curve forms with appropriate correction factors are available at a moment‘s notice. The earthing inputs “E” and the input “PE” are connected internally to the unit’s secondary ground Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Automatic switch-over to DOCSIS or EuroDOCSIS The interface modules EuroDOCSIS/HFC network Monitoring of 5 ... 90 VAC 230 VAC 99811859_EN.indd 7 22.03.2012 14:24:43 Technical data Type TDS 10-PWR Order no. 26210712 Receiver (downstream) Modulation 64/256 QAM Symbol rate DOCSIS MSym/s 5.056941 (64 QAM)/5.360537 (256 QAM) Symbol rate EuroDOCSIS MSym/s 6.952 (64 QAM)/6.952 (256 QAM) Frequency range MHz 90 to 862 Channel bandwidth DOCSIS/EuroDOCSIS MHz 6/8 Input level range dBμV 49 to 79 Input impedance Ω 75 TDMA QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM S-CDMA QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM kSym/s 160, 320, 640, 1,280, 2,560 Frequency range MHz 5 to 65 Channel bandwidth kHz 200, 400, 800, 1,600, 3,200, 6,400 Output level range dBμV 68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM), 68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA) Output impedance Ω 75 Transmitter (upstream) Modulation Symbol rate MAC protocol Excentis EuroDOCSIS 2.0/MCNS DOCSIS 2.0 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Management Safety Baseline Privacy/Baseline Privacy Plus Data filtering 32 Unicast addresses Max. number of 65/230 VAC lines to be monitored 4 Connections Ethernet port Measurement interface RJ 45 10/100 BaseT (half/full duplex, auto-sensing) V rms, Sine Number of independent measurement inputs Measurement accuracy Lightning arrester Over-voltage resistance 5 ... 65 ... 90 4 %, Sine 4 kV 1.5 VAC rms 140 To CATV network F-type socket Voltage supply Supply voltage Nominal input voltage Screw terminals (L, N, PE) VAC 230 W Typ. 3.5 Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range °C -5 to +50 Power consumption General Protection class IP 20 Housing material PC and ABS Flammability rating 99811859/1/0312/ZWD/Ri Technical data subject to change. Technical data represent typical values. Network characteristics UL-94 standard All data are typical values unless stated otherwise. www.kathrein.de · E-mail: catv@kathrein.de KATHREIN-Werke KG ·Phone +49 8031 184-0 · Fax +49 8031 184-385 Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 Rosenheim/GERMANY 99811859_EN.indd 8 22.03.2012 14:24:58