TDS 10
(Euro)DOCSIS cable modem TDS 10
with extension modules
For remote meter monitoring and reading
• Low additional costs
• Easy installation of units
• 30 individual meters can be read with one device
• Monitoring of data transfer
99811859_EN.indd 1
22.03.2012 14:23:24
DOCSIS/EuroDOCSIS cable modem with M-Bus for
smart metering
The TDS 10 from Kathrein is a DOCSIS/EuroDOCSIS
2.0-compliant cable modem for installation rail mounting. It
is designed to transmit data for remote meter reading. The
TDS 10 automatically identifies if the protocol is DOCSIS or
EuroDOCSIS allowing easy commissioning without requiring
manual intervention.
The design has been specially optimised for installation in
meter cabinets. The form of the housing and the mounting
material fully meet the requirements for installation rail
mounting components.
The TDS 10 features an M-Bus master and is equipped
with three M-Bus clamps which allow connection of up to
30 M-Bus clients (slaves). The clients are fed through the
M-Bus; polarity is not to be taken into account when they
are connected.
The M-Bus is a robust two-wire bus designed for remote
reading of the following reader types:
- Heat meters
- Water meters
- Electricity meters
- Gas meters

Remote meter reading over an existing cable network

Ethernet interface (local service interface)

Three M-Bus interfaces in compliance with EN 13757,
with screw terminals

Connection of up to 30 meters

Integrated M-Bus master

Comprehensive SNMP management support:
MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device
MIB, Baseline Privacy Interface MIB, RF Interface MIB

Automatic switch-over to DOCSIS or EuroDOCSIS

Easy installation on installation rails

Easy registration onto DOCSIS or EuroDOCSIS CMTS
without requiring any special hardware/software settings

Integrated 230 VAC power supply with screw terminals
(L, N, PE)

Internal Web server for configuration of the Ethernet
interface (address: port: 192.168.100.1:81)
The M-Bus can be designed as a tree or star structure.
Normal telephone cables or category 5 cables can be used
as cabling.
M-Bus data transport:
The headend queries meter data over the TDS 10 on
TCP-Port 3007. The cable modem transacts the commands
and the corresponding M-Bus protocol to the M-Bus over
the serial interface. The received M-Bus data from the
addressed meter is then transmitted back to the headend
over the Ethernet interface (TCP) without interpretation by
the TDS 10. In co-operation with the respective providers,
this new modem opens the doors to totally new business
models for cable operators.
The TDS 10 M-Bus cable modem in use
NE 4
M-Bus
Power
Plant
Management
HFC-Netz mit
EuroDOCSIS
CMTS
Internet
Internet
VPN
99811859_EN.indd 2
22.03.2012 14:23:34
Technical data
Type
TDS 10
Order no.
26210221
Receiver (downstream)
Modulation
64/256 QAM
Symbol rate DOCSIS
MSym/s
5.057 (64 QAM)/5.361 (256 QAM)
Symbol rate EuroDOCSIS
MSym/s
6.952 (64 QAM)/6.952 (256 QAM)
Frequency range
MHz
90 to 862
Channel bandwidth DOCSIS/EuroDOCSIS
MHz
6/8
Input level range
dBμV
49 to 79
Input impedance
Ω
75
Modulation
TDMA
QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM
Symbol rate
kSym/s
160, 320, 640, 1,280, 2,560
Transmitter (upstream)
Frequency range
MHz
5 to 65
Channel bandwidth
kHz
200, 400, 800, 1,600, 3,200, 6,400
Output level range
dBμV
68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM),
68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA)
Output impedance
Ω
75
Network characteristics
MAC protocol
EuroDOCSIS 2.0/MCNS DOCSIS 2.0
Application protocol
UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http
SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device
MIB, Baseline Privacy Interface MIB, RF Interface MIB
Management
Safety
Baseline Privacy/Baseline Privacy Plus
Data filtering
32 Unicast addresses
Connections
To CATV network
F-type socket
To service PC
RJ 45-10/100 BaseT (half/full duplex, auto-sensing)
VDC
Three parallel-connected screw terminal pairs
M-Bus idle mode, logical “1”
VDC
36
M-Bus active mode, logical “0”
VDC
22
Baud
2,400
m
100
M-Bus interface
Max. number of M-Bus clients, 1.5 mA each
Default baud rate (configurable via SNMP-OID)
Max. bus length (JYSTY 2*0.8²)
30
Voltage supply
Supply voltage
Screw terminals (L, N, PE)
VAC
230
W
8.3
Dimensions (W x H x D)
mm
105 x 90 x 60
Operating temperature range
°C
-5 to +50
Weight
g
Approx. 300
Nominal input voltage
Power consumption (30 M-Bus clients connected)
General
Protection class
IP 20
Housing material
PC and ABS
Flammability rating
UL-94 standard
All data are typical values unless stated otherwise.
99811859_EN.indd 3
22.03.2012 14:23:40
M-Bus Ethernet converter for TDS 10
TDA 10-CS
TDA 10-232
26210694
26210700
TDA 10-CS, similar to picture
The TDA 10-CS from Kathrein is an interface converter for
bidirectional conversion of the M-Bus protocol into CS-Bus
protocol and vice-versa.
The Kathrein TDA 10-232 is an interface converter for
bidirectional conversion of the M-Bus protocol into RS 232
protocol and vice-versa.
The TDA 10-232 interface converter types are designed
for interface conversion, extend the connection options of
the TDS 10 on other interfaces beyond the M-Bus and are
constructed for installation rail mounting. Different TDA 10
interface converter types can be connected to an M-Bus so
that various interfaces can be operated with a
TDS 10. When connecting the interface modules, observe
the number of load units (M-Bus clients) that are limited by
current drain. A TDS 10 can feed up to 30 load units.

Remote meter reading over an existing cable network in
conjunction with the TDS 10

Powering over M-Bus connection

Easy installation on installation rails
Available types:
 TDA 10-CS: Conversion of M-Bus protocol into CS-Bus
protocol with independent data rates

 TDA 10-232: Conversion of the M-Bus protocol into the
RS 232 protocol with independent data rates
The interface modules
EuroDOCSIS/HFC network
M-Bus
230 VAC
99811859_EN.indd 4
CS-Bus
RS 232
22.03.2012 14:23:44
Technical data
Tec
Type
Orde no.
Order
TDA 10-CS
TDA 10-232
26210694
26210700
Conn
Connections
Inter
Interface
1
Baud rate (default value = 2400 baud)
M-Bus, one screw terminal pair
Baud
2,400 ... 9,600
Inter
Interface 2
CS bus
RS 232 interface (eHz)
Baud
300 ... 9,600
300 ... 9,600
Level for idle mode (logical “1”)
mA
17
-
Level for active mode (logical “0”)
mA
4
-
kByte
6
6 (3 for Push operation)
Baud rate (default value = 2,400 or 9,600 baud)
Max. reception data buffer
CS voltage
V
14
-
Over the M-Bus
Over the M-Bus
15
10
Load units on M-Bus
10
7
Number of slaves on interface 2
≤3
1
Voltage supply
Current drain from the M-Bus (for an M-Bus voltage of 36 V)
mA
General
Dimensions (W x H x D)
mm
25 x 90 x 60
Operating temperature range
°C
-5 to +50
LED signalling
Operational voltage
All data are typical values unless stated otherwise.
Ethernet interface with an
M-Bus interface for Smart Metering
TDS 10-Eth
The TDS 10-Eth from Kathrein is an Ethernet M-Bus
interface with an integrated M-Bus master for installation
rail mounting. It is designed to transmit M-Bus data over
Ethernet data networks.
The design has been specially optimised for installation
in installation cabinets. The form of the housing and the
mounting material fully meet the requirements for installation
rail mounting components.
the serial interface.
ce. The received M-Bus
M
data from the
addressed meter is then transmitted back to the headend
over the Ethernet interface (TCP) without interpretation by
the TDS 10-Eth.

Remote transmission of M-Bus data over Ethernet data
networks

Ethernet interface (RJ 45)

Three M-Bus interfaces in compliance with EN 13757,
with screw terminals
The M-Bus is a robust two-wire bus designed for the
transmission of various different measurement values and
can be arranged as a tree or star structure. As a two-wire
bus normal telephone cable or category 5 cable can be
used.

Comprehensive SNMP management support:
MIB-II; Ethernet-like MIB, Bridge MIB, RS 232-MIB

Integrated 230 VAC power supply with screw terminals
(L, N, PE)
M-Bus data transport:
The headend queries meter data over the TDS 10-Eth on
TCP-Port 3007. The TDS 10-Eth transacts the commands
and the corresponding M-Bus protocol to the M-Bus over

Easy installation on installation rails

Internal Web server for configuration of the Ethernet
interface (address: port: 192.168.100.1:81)
The TDS 10-Eth features an M-Bus master and is equipped
with three M-Bus clamps which allow connection of up to
30 M-Bus clients (meters or slaves). The clients are fed
through the M-Bus; polarity is not to be taken into account
when they are connected.
99811859_EN.indd 5
22.03.2012 14:23:57
The interface modules
M-Bus
M
Ethernet
CS-Bus
230 VAC
RS 232
36 V
24 V
-12 V
Technical data
Type
TDS 10-Eth
Order no.
26210702
Application protocol
UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http
Management
SNMP, MIB-II, Ethernet-like MIB, Bridge MIB,
Baseline Privacy Interface MIB
Safety
Baseline Privacy/Baseline Privacy Plus
Data filtering
32 Unicast addresses
Connections
Data network
RJ 45-10/100 BaseT (half/full duplex, auto-sensing)
M-Bus interface
Three parallel-connected screw terminal pairs
M-Bus idle mode, logical “1”
VDC
36
M-Bus active mode, logical “0”
VDC
22
Number of clients supplied (< 1.5 mA per client)
Default baud rate (configurable via SNMP-OID)
Max. bus length (JYSTY 2*0,8²)
30
Baud
2,400
m
100
Voltage supply
Supply voltage
Screw terminals (L, N, PE)
VAC
230
W
8.3
Dimensions (W x H x D)
mm
105 x 90 x 60
Operating temperature range
°C
-5 to +50
Weight
g
270
Nominal input voltage
Power consumption (30 M-Bus clients connected)
General
Protection class
IP 20
Housing material
PC and ABS
Flammability rating
UL-94 standard
All data are typical values unless stated otherwise.
99811859_EN.indd 6
22.03.2012 14:24:27
DOCSIS/EuroDOCSIS cable modem
with four 65 VAC monitoring inputs
TDS 10-PWR
The TDS 10-PWR from Kathrein is a DOCSIS/EuroDOCSIS
2.0-compliant cable modem for installation rail mounting.
It is designed to transmit data during the monitoring of up
to four remote-feed power supplies (65 VAC). Voltages are
measured cyclically and can be read out. If voltages fall
below a user-defined alarm threshold, an alarm will go off.
Different correction factors for various curve forms (sine,
trapezium, rectangle, etc.) can be entered into the MIB for
correct display of voltages.
The TDS 10-PWR automatically identifies if the protocol
is DOCSIS or EuroDOCSIS allowing easy commissioning
without requiring manual intervention.
The design has been specially optimised for installation
in installation cabinets. The form of the housing and the
mounting material fully meet the requirements for installation
rail mounting components.

Remote reading of four AC voltage values over the
existing cable network

Ethernet interface (local service interface)

Connection of up to four power supply lines using screw
terminals (USV) with 65 VAC



Easyy registration onto DOCSIS
DOCS or EuroDOCSIS CMTS
without requiring any special hardware/software settings

Integrated 230 VAC power supply with screw terminals
(L, N, PE)

Easy installation on installation rails

LEDs for:
Downstream carrier search, modem ready for data
traffic, Ethernet connection ok, measurement size alarm

Measurement of up to four AC voltage signals (polling,
cycle time < 5 seconds)

Display of measured values in Kathrein-MIB with
integration of SCTE-HMS-MIB for alarm thresholds

The measured value is the rectified mean, using the
correction factor for a sine wave (default). Many other
curve forms with appropriate correction factors are
available at a moment‘s notice.

The earthing inputs “E” and the input “PE” are
connected internally to the unit’s secondary ground
Comprehensive SNMP management support:
MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device
MIB, Baseline Privacy Interface MIB, RF Interface MIB
Automatic switch-over to DOCSIS or EuroDOCSIS
The interface modules
EuroDOCSIS/HFC network
Monitoring of 5 ... 90 VAC
230 VAC
99811859_EN.indd 7
22.03.2012 14:24:43
Technical data
Type
TDS 10-PWR
Order no.
26210712
Receiver (downstream)
Modulation
64/256 QAM
Symbol rate DOCSIS
MSym/s
5.056941 (64 QAM)/5.360537 (256 QAM)
Symbol rate EuroDOCSIS
MSym/s
6.952 (64 QAM)/6.952 (256 QAM)
Frequency range
MHz
90 to 862
Channel bandwidth DOCSIS/EuroDOCSIS
MHz
6/8
Input level range
dBμV
49 to 79
Input impedance
Ω
75
TDMA
QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM
S-CDMA
QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM
kSym/s
160, 320, 640, 1,280, 2,560
Frequency range
MHz
5 to 65
Channel bandwidth
kHz
200, 400, 800, 1,600, 3,200, 6,400
Output level range
dBμV
68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM),
68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA)
Output impedance
Ω
75
Transmitter (upstream)
Modulation
Symbol rate
MAC protocol
Excentis EuroDOCSIS 2.0/MCNS DOCSIS 2.0
Application protocol
UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http
SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device MIB,
Baseline Privacy Interface MIB, RF Interface MIB
Management
Safety
Baseline Privacy/Baseline Privacy Plus
Data filtering
32 Unicast addresses
Max. number of 65/230 VAC lines to be monitored
4
Connections
Ethernet port
Measurement interface
RJ 45 10/100 BaseT (half/full duplex, auto-sensing)
V rms,
Sine
Number of independent measurement inputs
Measurement accuracy
Lightning arrester
Over-voltage resistance
5 ... 65 ... 90
4
%, Sine
4
kV
1.5
VAC rms
140
To CATV network
F-type socket
Voltage supply
Supply voltage
Nominal input voltage
Screw terminals (L, N, PE)
VAC
230
W
Typ. 3.5
Dimensions (W x H x D)
mm
105 x 90 x 60
Operating temperature range
°C
-5 to +50
Power consumption
General
Protection class
IP 20
Housing material
PC and ABS
Flammability rating
99811859/1/0312/ZWD/Ri Technical data subject to change. Technical data represent typical values.
Network characteristics
UL-94 standard
All data are typical values unless stated otherwise.
www.kathrein.de · E-mail: catv@kathrein.de
KATHREIN-Werke KG ·Phone +49 8031 184-0 · Fax +49 8031 184-385
Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 Rosenheim/GERMANY
99811859_EN.indd 8
22.03.2012 14:24:58
Download