PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD,BORONIA DRAWING INDEX S1 - DRAWING INDEX & GENERAL NOTES S2 - FOOTING PLAN S4 - LEVEL 1 FLOOR PLANS S5 - ROOF FRAMING PLANS S6 - ROOF FRAMING DETAILS S7 - WALL ELEVATIONS - SHEET 1 S8 - WALL ELEVATIONS - SHEET 2 S9 - FOOTING DETAILS S10 - CONCRETE DETAILS - SHEET 1 BUILDERS SHALL MAKE REFERENCE TO THE GEOTECHNICAL INVESTIGATION REPORT PREPARED BY HARDROCK GEOTECHNICAL, FILE No. 121214, DATE: 12 OCT 2012 FOR RECOMMENDATIONS AND GUIDANCE, INCLUDING BELOW THE EXISTING GROUND SURFACE.THE BUILDER SHALL REFER GEOTECHNICAL INVESTIGATION REPORT FOR SITE PREPARATION, TEMPORARY WORKS, DESIGN REQUIREMENTS, ETC. THE FOOTINGS HAVE BEEN DESIGNED FOR THE FOLLOWING ALLOWABLE BEARING PRESSURES: SLABS ON GROUND SHALL BE PLACED ON A 0.2mm POLYETHLENE MEMBRANE. LAP MEMBRANE 100mm MINIMUM, AND SEAL WITH ADHESIVE TAPE TO ENSURE A COMPLETE VAPOUR BARRIER. ELEMENT CAPACITY BORED PIER 270 kPa U.N.O APPROVAL OF THE FOUNDATION MATERIAL SHALL BE OBTAINED FROM THE ENGINEER OR BUILDING SURVEYOR, PRIOR TO PLACING OF CONCRETE. CAMBER REQUIREMENTS, IF ANY, IN BEAMS AND SLABS SHALL BE AS NOTED ON THE DRAWINGS. ANY OVER EXCAVATION SHALL BE BACK FILLED WITH CONCRETE GRADE N15. S11 - CONCRETE DETAILS - SHEET 2 EXCAVATION NEAR FOOTINGS SHALL NOT EXTEND BELOW FOUNDATION LEVEL WITHOUT THE ENGINEERS APPROVAL. ALL FOOTINGS SHALL BE LOCATED CENTRALLY UNDER WALLS AND COLUMNS U.N.O. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ANY EXCAVATION IN A STABLE CONDITION WITHOUT ADVERSELY AFFECTING SURROUNDING PROPERTY INCLUDING SERVICES. THIS INCLUDES OBTAINING ALL NECESSARY APPROVALS FOR SHORING AND ANCHORING SYSTEMS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND LOCATING ALL EXISTING UNDERGROUND SERVICES PRIOR TO ANY EXCAVATION COMMENCING. FOOTING FOUNDATION BASES ARE TO BE PROTECTED FROM WEATHERING WITH A 50mm MINIMUM, N15 CONCRETE BLINDING LAYER IF EXPOSED FOR MORE THAN 12 HOURS PROIR TO PLACEMENT OF CONCRETE. DEPTHS SPECIFIED FOR FOOTING ARE MINIMUM DIMENSIONS ONLY.GREATER DEPTH MAY BE NECESSARY TO ACHIEVE SPECIFIED FOUNDATION BASE. WHEREVER A NEW FOOTING IS LOCATED CLOSE TO AN EXCAVATION, BATTER, EXISTING FOOTING OR SERVICE WHICH IS DEEPER THAN THE NEW FOOTING, THE FOUNDING DEPTH OF THE NEW FOOTING SHALL BE INCREASED WITH THE USE OF BLINDING CONCRETE AS SHOWN BELOW. NEW FOOTING S12 - TYPICAL AFS WALL CONNECTION DETAILS S13 - CONCRETE STAIR DETAILS GENERAL NOTES THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS MAY BE ISSUED. ANY DISCREPANCIES OR OMISSIONS SHALL BE REFERRED TO THE ENGINEER FOR A DECISION BEFORE PROCEEDING WITH THE WORK. ALL WORKMANSHIP AND MATERIAL SHALL COMPLY WITH THE BUILDING CODE OF AUSTRALIA AS AMENDED AND THE APPROPRIATE AND CURRENT AUSTRALIAN STANDARDS. ALL CODES REFERRED TO IN THESE NOTES ARE THE LATEST EDITION WITH ALL AMENDMENTS. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE. BLINDING CONC. 4 5° DIMENSIONS SHALL NOT BE OBTAINED BY SCALING THE ENGINEERING DRAWINGS. DURING CONSTRUCTION THE STRUCTURE SHALL BE MAINTAINED IN A STABLE CONDITION AND NO PART SHALL BE OVERSTRESSED. CONCRETE SHALL HAVE A SLUMP OF 80mm, A MAXIMUM AGGREGATE SIZE OF 20mm AND A STRENGTH GRADE AS TABULATED BELOW: THE CONTRACTOR SHALL PROVIDE ALL RELEVANT NOTES TO SUB-CONTRACTORS. ELEMENT THE WORD "CONTRACTOR" USED IN THESE NOTES REFERS TO THE COMPANY OR PERSON WHO IS RESPONSIBLE FOR THE CONSTRUCTION OF THE WORKS IN ACCORDANCE WITH THESE DRAWINGS. STRENGTH GRADE U.N.O PIER, FOOTING & FOOTING BEAMS N32 SLAB ON GROUND WALLS N32 N40 THE ARCHITECT/BUILDING DESIGNER IS RESPONSIBLE FOR THE PROVISION OF ADEQUATE FIRE RATED MATERIALS AND DETAILS IN ACCORDANCE WITH THE CURRENT BCA. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED IN THE FORM TO GIVE MAXIMUM COMPACTION WITHOUT SEGREGATION OF THE CONCRETE. THE STRUCTURAL ELEMENTS HAVE BEEN DESIGNED FOR THE FOLLOWING LOADS; DESIGN LOADS ITEM SDL (kPa) LL (kPa) THE BEAMS ARE NOTED 'DEPTH x WIDTH' ON THE DRAWINGS AND INCLUDES SLAB THICKNESS IF ANY. SIZE OF CONCRETE ELEMENTS DOES NOT INCLUDE THICKNESS OF APPLIED FINISH OF GROOVES. 5.0 N/A N/A N/A EARTHQUAKE DESIGN CATEGORY (EARTHQUAKE LOADS TO AS1170 pt.4) A REGIONAL WIND SPEED VR (DESIGN WIND LOADS TO AS1170 pt.2) 45 m/s TERRAIN CATEGORY 3 UNLESS SHOWN OTHERWISE ON THE DRAWINGS, ALL CONNECTIONS SHALL HAVE THE FOLLOWING MINIMUM REQUIREMENTS; EXPOSURE CONDITIONS ADMIXTURES ARE NOT TO BE USED UNLESS APPROVED BY THE ENGINEER. UNDER NO CIRCUMSTANCES SHALL THE W/C RATIO EXCEED 0.50, UNLESS WRITTEN APPROVAL IS OBTAINED FROM THE ENGINEER. CONCRETE MUST BE SEPARATED FROM SUPPORTING BRICKWORK BY TWO LAYERS OF AN APPROVED DEBONDING MEMBRANE. ALL NON-LOADBEARING WALLS SHALL BE KEPT CLEAR OF THE UNDERSIDE OF ELEMENTS BY 20mm U.N.O. STRIPPING OF FORMS AND REMOVAL OF FORMWORK SHALL TAKE PLACE IN ACCORDANCE WITH A PROCEDURE AGREED BY THE ENGINEER AND NOT BEFORE CONCRETE HAS REACHED 75% OF IT'S SPECIFIED STRENGTH. NO MASONRY WALLS SHALL BE BUILT ON SUSPENDED ELEMENTS UNTIL ALL PROPS HAVE BEEN REMOVED. FORMWORK CLASS SHALL BE IN ACCORDANCE WITH AS3610. FINISHES TO ALL EXPOSED SURFACES TO BE CLASS 3. SURFACES PERMANENTLY CONCEALED FROM VIEW MAY BE CLASS 5. LOCATION AND DETAILS OF CONSTRUCTION JOINTS IF NOT SHOWN ON PLAN SHALL BE TO DETAILS APPROVED BY THE ENGINEER. HOLES, CHASES OR PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL NOT BE PLACED IN CONCRETE MEMBERS WITHOUT THE PRIOR APPROVAL OF THE ENGINEER. CONDUITS, PIPES AND THE LIKE SHALL NOT BE PLACED WITHIN THE CONCRETE COVER. PROVIDE A 20x20 CHAMFER TO ALL CORNERS INCLUDING RE-ENTRANT CORNERS AND EDGES OF ALL EXPOSED CONCRETE U.N.O. 1. SURFACES OF MEMBERS IN CONTACT WITH THE GROUND. (a) SURFACES PROTECTED BY DAMP PROOF MEMBRANE. (b) UNPROTECTED SURFACES. 50 50 50 50 2. SURFACES OF MEMBERS IN INTERIOR ENVIROMNEMTS. i.e. FULLY ENCLOSED WITHIN A BUILDING. 25 25 25 3. SURFACES OF MEMBERS IN ABOVE GROUND EXTERIOR ENVORONMENTS. EXPOSURE CLASS B1. N/A TIMBER NOTES ALL TIMBER FRAMING IS TO BE IN ACCORDANCE WITH AS1684, RESIDENTIAL TIMBER FRAMED CONSTRUCTION CODE AND AS1720, TIMBER STRUCTURES CODE. ALL TIMBER SHALL BE DRY, ie: LESS THAN 15% MOISTURE CONTENT AT THE TIME OF CONSTRUCTION AND SHALL BE PROTECTED AND/OR TREATED AS NOTED. ALL TIMBER BEAMS AND LINTELS ARE TO BEAR ON 2 No. 90x45 MGP10 STUDS, U.N.O. BEAMS/STUDS HAVING MORE THAN 1 MEMBER ARE TO BE NAIL LAMINATED TOGETHER IN ACCORDANCE WITH AS1684. ALL PROPRIETARY CONNECTORS AND FIXINGS TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. ALL EXTERNAL TIMBER SHALL HAVE A SUITABLE DURABILITY FOR RELEVANT CLIMATE AND EXPECTED SERVICE LIFE, AND CONDITIONS. GUIDANCE ON DURABILITY IS GIVED IN AS1684, APPENDIX C. REINFORCEMENT NOTES ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600 AND OTHER RELEVANT CODES. REINFORCEMENT TYPE AND GRADE: AUSTRALIAN GRADE STANDARD (MPa) N HOT ROLLED DEFORMED BAR AS/NZS 4671 500N R STRUCTURAL GRADE PLAIN BAR AS/NZS 4671 250N W HARD DRAWN STEEL REINFORCING WIRE AS/NZS 4671 500L L COLD ROLLED DEFORMED BAR AS/NZS 4671 500L SL COLD ROLLED DEFORMED BAR AS/NZS 4671 500L RL COLD ROLLED DEFORMED BAR AS/NZS 4671 500L NOTATION OF SLAB REINFORCEMENT: N.F - NEAR FACE F.F - FAR FACE LAYER B2 E.F - EACH FACE E.W - EACH WAY LAYER T1 LAYER T2 30 1. SURFACES OF MEMBERS IN CONTACT WITH THE GROUND. (a) SURFACES PROTECTED BY DAMP PROOF MEMBRANE. (b) UNPROTECTED SURFACES. MINIMUM TENSION LAP LENGTH (mm) 400 500 700 950 1250 1500 1700 (400) (600) (900) (1200) (1500) (1900) (2250) COVER F'c=25MPa F'c=32MPa F'c=40MPa 50 50 50 50 50 50 2. SURFACES OF MEMBERS IN INTERIOR ENVIROMNEMTS. i.e. FULLY ENCLOSED WITHIN A BUILDING. 25 25 25 3. SURFACES OF MEMBERS IN ABOVE GROUND EXTERIOR ENVORONMENTS. EXPOSURE CLASS B1. N/A 40 30 GALVANISED STEELWORK THAT IS SITE WELDED OR SUSTAINS ANY OTHER KIND OF SURFACE DAMAGE IS TO BE PREPARED TO AS1627.2 CLASS 3 AND PRIMED WITH 2 COATS OF GALVINITE (MANUFACTURED BY JOTUN) TO MANUFACTURERS SPECIFICATIONS. FOR GALVANISED STEELWORK, MATING SURFACES OR FRICTION TYPE BOLTED CONNECTIONS SHALL BE POST TREATED BY DISC ABRASION (OR EQUIVALENT) TO IMPROVE THE SURFACES SLIP FACTOR. THE TREATMENT SHALL PROVIDE THE SURFACES WITH A MINIMUM SLIP FACTOR OF 0.35 IN ACCORDANCE WITH AS4100 U.N.O. ALL STRUCTURAL STEEL SHALL BE: GRADE 300 FOR HOT ROLLED PLATES GRADE 300PLUS FOR UB, UC PFC AND ANGLES GRADE 300 FOR WB, WC GRADE 350 FOR SHS, CHS GRADE 450 FOR DURAGAL SECTIONS TO AS1163, AS1594, AS3678 AND AS3679 U.N.O. ON THE DRAWINGS. LAP REINFORCEMENT ONLY AT LOCATIONS SHOWN ON THE DRAWINGS OR AS APPROVED. U.N.O., LAP ALL BARS AS TABULATED BELOW: BAR SIZE MINIMUM TENSION LAP LENGTH (mm) N12 N16 N20 N24 N28 N32 N36 25mm MINIMUM A MAXIMUM OF THREE SHEETS OF FABRIC SHALL BE LAPPED AT ANY POINT. REINFORCEMENT SHALL NOT BE BENT, HEATED OR WELDED ON SITE WITHOUT THE ENGINEERS PRIOR APPROVAL. ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED BY PLASTIC BAR CHAIRS OR PLASTIC TIPPED WIRE BAR CHAIRS. REMOVE ALL DEBRIS AND FULLY SUPPORT FORMS BEFORE PLACING CONCRETE 400 500 700 950 1250 1500 1700 (400) (600) (900) (1200) (1500) (1900) (2250) PURLINS AND GIRTS SHALL BE MANUFACTURED BY BHP BUILDING PRODUCTS, STRAMIT, OR OTHER APPROVED MANUFACTUER. MINIMUM GRADE SHALL BE G450 COMPLYING WITH AS1397, WITH A MINIMUM GALVANIZED COATING OF Z350 (350g/m2) U.N.O. WHERE HOT DIP GALVANISED PURLINS ARE SPECIFIED ON THE DRAWINGS, THEY SHALL COMPLY WITH AS/NZS4680. LAP LENGTH SHOWN IN BRACKETS APPLY TO HORIZONTAL BARS WITH MORE THAN 300mm OF CONCRETE CAST BELOW THE BAR. CLEAT CONNECTIONS AND BOLTING AND BRIDGING ARE TO BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. FABRIC SHALL BE LAPPED SUCH THAT THE TWO OUTERMOST WIRES OF ONE SHEET OVERLAP THE TWO OUTERMOST WIRES OF THE OTHER SHEET BY 25mm MINIMUM. ALL SPLICE LOCATIONS TO BE APPROVED BY ENGINEER PRIOR TO COMMENCING PLACEMENT OF REINFORCEMENT. AT CONSTRUCTION JOINTS, USE STRAIGHT, SMOOTH DOWELS FREE OF BURS AND SAWN TO LENGTH. INSTALL DOWELS PARALLEL TO SURFACE OF SLAB AND PERPENDICULAR TO PLANE OF JOINT. MAINTAIN DOWEL ALIGNMENT BY USE OF SUITABLE SUPPORT ASSEMBLY TO ENSURE HORIZONTAL AND VERTICAL ALIGNMENT TOLERANCE OF 5 in 400. DO NOT INSERT DOWELS DURING PLACEMENT OF CONCRETE. WHERE REINFORCEMENT IS CONTINUOUS THROUGH A CONSTRUCTION JOINT, FULLY SCABBLE THE EXISTING CONCRETE FACE PRIOR TO POURING AGAINST IT. WELDING SHALL BE CATEGORY 'SP' (SPECIAL PURPOSE), CARRIED OUT IN ACCORDANCE WITH AS1554.1 UNO. WELDING CONSUMABLES TO BE E48XX U.N.O. BUTT WELDS SHALL BE FULL STRENGTH COMPLETE PENETRATION WELDS. 25mm MINIMUM REINFORCEMENT NOTES ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600 AND OTHER RELEVANT CODES. REINFORCEMENT TYPE AND GRADE: TYPE THE ENGINEER'S REVIEW OF SHOP DRAWINGS SHALL BE LIMITED TO THE CHECKING OF MEMBER SIZES, CONNECTION CONFIGURATIONS AND CAMBERS. IT DOES NOT INCLUDE CHECKING DIMENSIONS. THE CONTRACTOR IS RESPONSIBLE TO ENSURE COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. STEELWORK FABRICATION MUST NOT COMMENCE UNTIL THE SHOP DRAWINGS HAVE BEEN REVIEWED AND STAMPED AS APPROVED BY THE ENGINEER. COVER SPECIFIED ALSO APPLIES LOCALLY AT RECESSES, DRIP GROVES, ETC. LAP LENGTH SHOWN IN BRACKETS APPLY TO HORIZONTAL BARS WITH MORE THAN 300mm OF CONCRETE CAST BELOW THE BAR. FABRIC SHALL BE LAPPED SUCH THAT THE TWO OUTERMOST WIRES OF ONE SHEET OVERLAP THE TWO OUTERMOST WIRES OF THE OTHER SHEET BY 25mm MINIMUM. SYMBOL BAR NOTATION GIVES THE FOLLOWING INFORMATION IN THIS ORDER: No. OF BARS, TYPE, BAR SIZE (mm), SPACING (mm), LAYER. E.G. 2N16-250 T1 EXPOSURE CONDITIONS AUSTRALIAN STANDARD GRADE (MPa) N HOT ROLLED DEFORMED BAR AS/NZS 4671 500N R STRUCTURAL GRADE PLAIN BAR AS/NZS 4671 250N W HARD DRAWN STEEL REINFORCING WIRE AS/NZS 4671 500L L COLD ROLLED DEFORMED BAR AS/NZS 4671 500L SL COLD ROLLED DEFORMED BAR AS/NZS 4671 500L RL COLD ROLLED DEFORMED BAR AS/NZS 4671 500L A MAXIMUM OF THREE SHEETS OF FABRIC SHALL BE LAPPED AT ANY POINT. ANY WELDING SYMBOLS USED IN THESE DRAWINGS ARE IN ACCORDANCE WITH AS1101.3 REINFORCEMENT SHALL NOT BE BENT, HEATED OR WELDED ON SITE WITHOUT THE ENGINEERS PRIOR APPROVAL. ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED BY PLASTIC BAR CHAIRS OR PLASTIC TIPPED WIRE BAR CHAIRS. REMOVE ALL DEBRIS AND FULLY SUPPORT FORMS BEFORE PLACING CONCRETE WELDING INSPECTION TO BE CARRIED OUT AS PER REQUIREMENTS OF AS1554.1. ALL BOLTS SHALL BE COMMERCIAL GRADE TO AS1111 OR HIGH TENSILE TO AS1252, USED IN CONFORMITY WITH AS4100. BOLT DESIGNATION; HIGH TENSILE BOLT TO SNUG TIGHT:..........M20 8.8/S COMMERCIAL GRADE BOLTS:........................M20 4.6/S HIGH TENSILE BOLTS FULLY TENSIONED:....M20 8.8/TF HIGH TENSILE BOLTS IN BEARING, BUT TENSIONED:.........................................M20 8.8/TB ALL SPLICE LOCATIONS TO BE APPROVED BY ENGINEER PRIOR TO COMMENCING PLACEMENT OF REINFORCEMENT. AT CONSTRUCTION JOINTS, USE STRAIGHT, SMOOTH DOWELS FREE OF BURS AND SAWN TO LENGTH. INSTALL DOWELS PARALLEL TO SURFACE OF SLAB AND PERPENDICULAR TO PLANE OF JOINT. MAINTAIN DOWEL ALIGNMENT BY USE OF SUITABLE SUPPORT ASSEMBLY TO ENSURE HORIZONTAL AND VERTICAL ALIGNMENT TOLERANCE OF 5 in 400. DO NOT INSERT DOWELS DURING PLACEMENT OF CONCRETE. WHERE REINFORCEMENT IS CONTINUOUS THROUGH A CONSTRUCTION JOINT, FULLY SCABBLE THE EXISTING CONCRETE FACE PRIOR TO POURING AGAINST IT. ALL BOLTS, NUTS AND WASHERS SHALL BE HOT DIP GALVANISED. WHERE FULLY TENSIONED BOLTS ARE REQUIRED, TENSIONING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF AS4100. ALL BOLT HOLES SHALL BE 2mm LARGER THAN THE NORMAL BOLT DIAMETER. ALL STEELWORK BELOW GROUND LEVEL SHALL BE ENCASED IN CONCRETE WITH A MINIMUM COVER OF 75mm. LAYER B1 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By WELDS 6mm CFW ALL AROUND, BOLTS M20 8.8/S, WITH MIN. 2 BOLTS PER CONNECTION, GUSSET & CLEAT PLATES 10mm THICK, CAP PLATES 12mm THICK, BASE PLATES 20mm THICK. ALL STRUCTURAL STEELWORK MUST BE PROTECTED AGAINST CORROSION IN ACCORDANCE WITH THE BUILDING CODE OF AUSTRALIA Vol 2, CLAUSE 3.4.4.4 & TABLE 3.4.4.2. CLEAR COVER TO FACE OF ALL REINFORCEMENT SHALL CONFORM TO THE FOLLOWING TABLE U.N.O. LAP REINFORCEMENT ONLY AT LOCATIONS SHOWN ON THE DRAWINGS OR AS APPROVED. U.N.O., LAP ALL BARS AS TABULATED BELOW: N12 N16 N20 N24 N28 N32 N36 LAYER T2 FABRIC NOTIFICATION GIVES THE FOLLOWING INFORMATION IN THIS ORDER: "SL" SYMBOL, FABRIC SIZE, LOCATION. E.G. SL918-TOP. LAY MESH SO THAT MINIMUM COVER IS TO MAIN WIRES. COVER SPECIFIED ALSO APPLIES LOCALLY AT RECESSES, DRIP GROVES, ETC. BAR SIZE c. d. e. LAYER B1 COVER F'c=25MPa F'c=32MPa F'c=40MPa 40 a. b. E.F - EACH FACE E.W - EACH WAY LAYER T1 LAYER B2 50 CONCRETE SLAB SURFACE FINISH TO BE STEEL TROWELLED, BURNISHED (NON-SLIP) OR BROOMED. TYPE N.F - NEAR FACE F.F - FAR FACE 50 ALL STEEL EMBEDDED ITEMS SHALL BE HOT DIP GALVANIZED IN ACCORDANCE WITH AS4680. SYMBOL NOTATION OF SLAB REINFORCEMENT: CLEAR COVER TO FACE OF ALL REINFORCEMENT SHALL CONFORM TO THE FOLLOWING TABLE U.N.O. TIMBER SHALL BE STORED AND HANDLED SO AS NOT TO BE DETRIMENTAL TO IT'S PERFORMANCE. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600 AND OTHER RELEVANT AUSTRALIAN STANDARDS. BAR NOTATION GIVES THE FOLLOWING INFORMATION IN THIS ORDER: No. OF BARS, TYPE, BAR SIZE (mm), SPACING (mm), LAYER. E.G. 2N16-250 T1 FABRIC NOTIFICATION GIVES THE FOLLOWING INFORMATION IN THIS ORDER: "SL" SYMBOL, FABRIC SIZE, LOCATION. E.G. SL918-TOP. LAY MESH SO THAT MINIMUM COVER IS TO MAIN WIRES. COMMENCE CURING OF CONCRETE IN ACCORDANCE WITH AS3600 AS SOON AS POSSIBLE AFTER PLACING AND FINISHING OR STRIPPING. THE CURING PROCEDURE IS TO BE SUBMITTED FOR APPROVAL TO THE ENGINEER SEVEN DAYS PRIOR TO PLACEMENT OF CONCRETE. ALL TIMBER STRESS GRADES NOMINATED SHALL BE IN ACCORDANCE WITH THE RELEVANT CODES, AND MEANS THE STRUCTURAL QUALITY OF A TIMBER SECTION. REFER EXISTING FOOTING, TO AS1720. SERVICE TRENCH, ETC. CONCRETE NOTES ALL DIMENSIONS SHOWN ON THE DRAWINGS SHALL BE VERIFIED ON SITE BY THE CONTRACTOR PRIOR TO CONSTRUCTION OR FABRICATION. 1.0 N/A N/A N/A ALL WORKMANSHIP AND MATERIALS TO BE IN ACCORDANCE WITH AS4100. WHERE NOT SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL ALLOW FOR ALL CLEATS, PENETRATIONS, CONNECTIONS, LINTELS AND ANY OTHER MISCELLANEOUS STEELWORK AS REQUIRED BY THE ARCHITECT OR OTHER CONSULTANTS' DRAWINGS OR AS NECESSARY TO COMPLETE THE WORKS. FOOTING NOTES S3 - GROUND FLOOR PLAN & SLAB ON GROUND DETAILS TYPICAL GYM BALCONY / TERRACE EQUIPMENT LOADS VEHICLE LOADS STRUCTURAL STEEL NOTES DRAWING GENERAL NOTES & DRAWING INDEX Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET N/A Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S1 Rev. -- M Y AR LE A B C D E F G H I J K D UN O B TIT L PF 1 TITLE BOUNDARY EB 1 TITLE BOUNDARY 3 PF 2 3 3 F.8 2 S9 S9 1 PF PF 2 PF 1 PF PF 3 2 PF 3 PF SF1 F.5 1 2 F.7 3 SF1 F.1 PF 2 PF PF 2 S9 2 S9 PF 3 PF F.6 EB PF 3 SF1 PF 3 TITLE BOUNDARY 5 PF PF 3 3 PF SF1 SF1 SF1 3 S9 PF 3 SF1 SF1 F.4 PF EB PF 3 EB SF1 4 EB PF EB PF 3 6 F.8 F.2 S9 S9 EB 1 PF 3 S9 EB EB 1 TITLE BOUNDARY ADJACENT PAVED PATIO F.2 S9 FOOTING PLAN NOTES: ADJACENT BRICK GARAGE ADJACENT BRICK GARAGE ADJACENT SINGLE STORY BRICK UNIT SCALE 1:100 1. REFER NOTES ON DRG. S1. 2. ALL PAD FOOTINGS AND STRIP FOOTINGS SHALL BE FOUNDED ON SILTY CLAY WITH A MINIMUM BEARING CAPACITY OF 180 kPa. MASS CONCRETE BLINDING SHALL BE PROVIDED TO EXTEND DOWN TO THE FOUNDING LEVEL WHERE REQUIRED. 3. FOR MAXIMUM BATTER SLOPE REFER GEOTECHNICAL REPORT 4. REFER TO ARCHITECTURAL DRAWINGS FOR STRUCTURE SETOUT DIMENSIONS AND FINISHED FLOOR LEVELS. 5. REFER BUILDING SERVICES DRAWINGS FOR CO-ORDINATION OF ALL UNDERGROUND SERVICES. 6. UNLESS NOTED OTHERWISE THE CENTRELINES OF COLUMNS AND WALLS SHALL COINCIDE WITH THE CENTRELINES OF THE FOOTINGS OR THE PAD FOOTINGS. PAD & STRIP FOOTING SCHEDULE MARK SIZES (mm) DEPTH (mm) PF1 1500 x 1500 800 SL81 BOTTOM PF2 1200 x 2800 800 SL81 BOTTOM PF3 800 x 800 600 SL81 BOTTOM SF1 600 WIDE 500 SL81 TOP & BOTTOM EB 400 WIDE 500 4TM11 TOP & BOTTOM REINFORCEMENT This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING FOOTING PLAN & FOOTING DETAILS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT - Scale @ A1 SIZE SHEET 1:100 U.N.O Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S2 Rev. -- M Y AR LE A B C D E F G H I J K D UN O B TIT L C.J C1 TITLE BOUNDARY 6 TITLE BOUNDARY SLAB ON GROUND. PROVIDE SL82 TOP THROUGHOUT. (U.N.O) SUSPENDED SLAB. PROVIDE RL918 TOP & BOTTOM (U.N.O). MAIN WIRES NORTH-SOUTH DIRECTION. C.J 4 F.4 C.J UP 3 F.8 RETAINING BLOCK WALL. REFER SECTION F.8 FOR DETAILS. 130 C.J N16-200 T&B (MIN. 10 BARS) F.6 F.7 S9 S9 C.J F.1 C.J C.J C.J UP F.5 S9 DN 130 F.2 F.8 C.J N16-200 T&B (MIN. 10 BARS) S9 S9 1 TITLE BOUNDARY ADJACENT PAVED PATIO 1 RETAINING BLOCK WALL. REFER SECTION F.8 FOR DETAILS. F.2 S9 ADJACENT SINGLE STORY BRICK UNIT GROUND FLOOR PLAN SLAB ON GROUND NOTES: 2. SLAB THICKNESSES SHALL BE 180mm UNLESS DEPICTED THUS: XXX 6. ALL SERVICES PENETRATIONS THROUGH FLOOR SLAB SHALL BE SLEEVED, NOT CORED. LEGEND: 150 AFS WALLS UNDER ONLY ARE SHOWN THUS: REINFORCEMENT SHOWN ON PLAN ARE DIAGRAMMATIC AND INDICATE THE SIZE AND NUMBER ONLY. THEY MAY REPRESENT MORE THAN ONE LENGTH OR PROFILE. 1. REFER NOTES ON DRG. S1. 2. 130mm MIN. SLAB ON GROUND U.N.O. 3. 4. 5. 150 AFS WALLS UNDER & OVER SHOWN THUS: INSITU COLUMNS UNDER ONLY ARE SHOWN THUS: INSITU COLUMNS UNDER & OVER SHOWN THUS: WALLS AND COLUMNS OVER ONLY SHOWN THUS: REFER TO CONCRETE DETAIL DRAWINGS FOR REINFORCEMENT TO TENDON ENDS, MINIMUM REINFORCEMENT TO BAND BEAMS ETC. 6. C.J. SLAB CONTROL JOINTS DEPICTED ON PLAN SHALL BE EITHER CONSTRUCTION OR SAWCUT JOINTS IN ACCORDANCE WITH DETAILS ON DRG S?. 2N16 BARS TOP x 1500 LONG. C.J. UNJOINTED RE-ENTRANT CORNER BASEMENT SLAB SUB-BASE: 0.2 mm THICK POLYTHENE MEMBRANE MOISTURE BARRIER ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. THICKNESS). REFER TO ARCHITECTURAL DRAWINGS FOR: - DIMENSIONS AND FINISHED FLOOR LEVELS - LOCATION AND PROFILE OF UPSTANDS - PITS ETC. 4H:1V SLOPE TO SHOULDER OF KEY. 250 DRAINAGE PIT OR COLUMN WITHIN PAVEMENT This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. 30mm DEEP SAW CUT MADE WITHIN 24 HOURS OF POURING SLAB UNLESS AGREED OTHERWISE WITH THE ENGINEER. DRAPE SLAB REINFORCEMENT TO 50mm BOTTOM COVER. SAWCUT C.J. NOTE: By 3H:1V SLOPE TO BASE. CUT-OUT 150mm LENGTH OF TRANSVERSE WIRES LEAVING WIRES AT 600 CTS. 2N16 BARS TOP x 1500 LONG. BASEMENT SLAB SUB-BASE: 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). SAWCUT JOINT CONTROL JOINT SCALE = N/A Revision 250 OR C.J. TYPICAL CORNER BAR DETAILS Date BASEMENT SLAB SUB-BASE: 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). PROPOSED PIT/COLUMN. DISCONTINUOUS JOINTS No. EQ EQ EQ CONSTRUCTION JOINT C.J. THE CONTRACTOR SHALL ALLOW FOR ADDITIONAL REINFORCEMENT REQUIRED FOR ANY CONSTRUCTION JOINTS, TEMPORARY PENETRATIONS REQUIRED IN SLABS DURING CONSTRUCTION, ETC. 20 2N16 BARS TOP x 1500 LONG. REFER GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION REQUIREMENTS C.J. 5. WHERE REINFORCEMENT BARS ARE CALLED UP IN ONE DIRECTION ON PLAN, DISTRIBUTION BARS ARE REQUIRED IN THE TRANSVERSE DIRECTION. 8. ALL DISTRIBUTION BARS SHALL BE N12-300 (300 LAPS) UNLESS SHOWN OTHERWISE ON PLAN OR 9. SECTIONS. REFER TO ARCHITECTURAL DRAWINGS FOR: - DIMENSIONS AND FINISHED FLOOR LEVELS - CHAMFERS TO CONCRETE EDGES - LOCATION AND PROFILE OF UPSTANDS ETC. 200 MIN. REFER NOTES ON DRG. S1. STOP REINFORCEMENT 25mm CLEAR OF JOINT. C.J. 7. 1. 4. C.J. SCALE 1:100 SUSPENDED FLOOR SLAB NOTES: 2 ADJACENT BRICK GARAGE ADJACENT BRICK GARAGE 3. C1 C.J C1 2 C1 1500 TYP. S9 C.J S9 DN TITLE BOUNDARY 3 C.J C1 C.J N16-200 T&B (MIN. 8 BARS) GRATED TRENCH. REFER DETAILS ON DRG. S11 (typ.) C.J S9 C.J 130 5 Date Revision By SCALE = N/A ALL CORNER BARS NOT NECESSARILY SHOWN ON PLAN. DRAWING GROUND FLOOR PLAN & SLAB ON GROUND DETAILS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT - Scale @ A1 SIZE SHEET 1:100 U.N.O Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S3 Rev. -- FLOOR SLAB NOTES: M A B C D E F G H I J K L LIGHTWEIGHT ROOF ABOVE CONCRETE SLAB (WITH SL92 T&B). REFER DRG. S5 FOR DETAILS. N16-300 T x 3500 LONG. 1. REFER NOTES ON DRG. S1. 2. SLAB THICKNESSES SHALL BE 180mm UNLESS DEPICTED THUS: XXX 3. WHERE REINFORCEMENT BARS ARE CALLED UP IN ONE DIRECTION ON PLAN, DISTRIBUTION BARS ARE REQUIRED IN THE TRANSVERSE DIRECTION. ALL DISTRIBUTION BARS SHALL BE N12-300 (300 LAPS) UNLESS SHOWN OTHERWISE ON PLAN OR SECTIONS. 4. REINFORCEMENT AND TENDONS SHOWN ON PLAN ARE DIAGRAMMATIC AND INDICATE THE SIZE AND NUMBER ONLY. THEY MAY REPRESENT MORE THAN ONE LENGTH OR PROFILE. 5. REFER TO CONCRETE DETAIL DRAWINGS FOR REINFORCEMENT TO TENDON ENDS, MINIMUM REINFORCEMENT TO BAND BEAMS ETC. 6. POST-TENSIONING DOCUMENTATION FOR CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. REFER NOTES ON DRG. S1. 180 L1.2 S- N12-300 T x 2000 LONG. 6N16-200 T&B L1.1 S- 230 1000 (TYP.) 3 180 LOAD BEARING STUD WALL. (TYP.) 6N16-200 T&B x 3000 LONG 2 DN 180 230 230 DN 5 180 2400 WIDE x 400 DEEP BAND BEAM 230 130 180 N16-300 T x 3000 LONG. 180 2400 WIDE x 400 DEEP BAND BEAM 180 2400 WIDE x 400 DEEP BAND BEAM 4 6 L1.5 S- 230 N16-300 T x 3500 LONG. 3 SPECIFIC DESIGN CRITERIA: (i) MAXIMUM TOTAL DEFLECTION FOR ALL MEMBERS: Lef/500 FOR SPANS Lef/250 FOR CANTILEVERS (ii) ADDITIONAL DEAD LOAD (WALLS, FINISHES, CEILING, SERVICES, ETC.) SHOULD BE CALCULATED WITH 1.2 kPa BEING THE MINIMUM ADOPTED. (iii) THE CONTRACTOR SHALL MAKE HIS OWN ASSESSMENT OF SLAB RESTRAINT WITH THE MINIMUM LEVEL OF P/A IN THE SECONDARY DIRECTION BEING 1.0 MPa FOR UNEXPOSED SLABS. (iv) CO-ORDINATE ALL SLAB PENETRATIONS FOR TENDON LAYOUT. 2 DN 130 6N16-200 T&B x 3000 LONG 1 6N16-200 T&B x 3000 LONG 6N16-200 T&B x 3000 LONG L1.3 L1.4 S- S- LIGHTWEIGHT ROOF ABOVE CONCRETE SLAB. REFER DRG. S5 FOR DETAILS. 1 N12-300 T x 2000 LONG. 7. THE CONTRACTOR SHALL ALLOW FOR ADDITIONAL REINFORCEMENT REQUIRED FOR ANY CONSTRUCTION JOINTS, TEMPORARY PENETRATIONS REQUIRED IN SLABS DURING CONSTRUCTION, ETC. 8. REFER TO ARCHITECTURAL DRAWINGS FOR: - DIMENSIONS AND FINISHED FLOOR LEVELS - CHAMFERS TO CONCRETE EDGES - LOCATION AND PROFILE OF UPSTANDS ETC. 9. ALL SERVICES PENETRATIONS THROUGH FLOOR SLAB SHALL BE SLEEVED, NOT CORED. 10. LEGEND: LEVEL 1 PROFILE AND REINFORCEMENT PLAN M A B C D E F G H I J K L 1/4S 2/4S HORIZONTAL. 2/3S HORIZONTAL. 2/3S HORIZONTAL. 150 AFS WALLS UNDER ONLY ARE SHOWN THUS: 2/3S HORIZONTAL. 1/3S HORIZONTAL. 2/4S HORIZONTAL. 150 AFS WALLS UNDER & OVER SHOWN THUS: 6 2/4S HORIZONTAL. INSITU COLUMNS UNDER ONLY ARE SHOWN THUS: 2/4S 4 INSITU COLUMNS UNDER & OVER SHOWN THUS: WALLS AND COLUMNS OVER ONLY SHOWN THUS: 5 2/3S ADDITIONAL 2/4S 2/4S 3 4/5S 4/5S 4/5S 3 2/4S 2 2 DN DN DN 1 1 4S AT 1200 CTS. 4S AT 1200 CTS. 4S AT 1500 CTS. LEVEL 1 POST-TENSIONING PLAN This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING LEVEL 1 PLANS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET 1:100 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S4 Rev. -- M Member Schedule Mark K L CANTILEVER L1 DS DS box gutter L1 L1 L3 WP1 WP1 RIDGE LINE 140 x 45 MGP10 L2 - L3 190 x 45 MGP10 2000 L4 170 x 45 MGP10 2500 RB1 240 x 45 MGP10 - 2000mm Min Back Span Max 1800MM Cantilever RB2 240 x 63 LVL13 or 290 x 45 (F17) KDHW 3800 R1 PSW35 (35 X 90) MGP10 @ 900 CTS OR 190 X 45 MGP10 @900 CTS 5400 WP1 190 x 45 F17 KDHW FIXED TO EVERY STUD VIA 2 MIN. NAILS. (U.N.O) R2 140 x 45 MPG10 @ 900 CTS 1200 RB3 2/290 x 45 F17 3800 1100 L1 RB2 RB3 RIDGE LINE L1 fall 2 Max Span L4 DS RB1 BOX GUTTER L1 2 L1 L1 R1 RB1 box gutter 1 L1 fall DS L4 L4 BOX GUTTER DS L1 L4 BOX GUTTER RB1 L4 L4 P2 DS L1 R1 (CANOPY) BOX GUTTER DS fall DS box L1 gutter L4 BOX GUTTER L4 CANTILEVER R1 (CANOPY) fall L4 R1 (CANOPY) RB1 CANTILEVER CANTILEVER RB3 L1 fall 1 J DS L1 I DS L1 H CANTILEVER DS fall RB1 DS RB2 DS 3 G R1 (CANOPY) BOX GUTTER RB1 RB1 LOAD BEARING STUD WALL UNDER. 90x45 MGP10 AT 450CTS (TYPICAL) F R1 (CANOPY) box gutter L4 E CANTILEVER R1 (PITCHED ROOF) L4 4 D RB1 CANTILEVER C RB1 B RB1 A Member Size RIDGE LINE L1 L1 L1 L1 L1 L1 L1 L1 L1 box gutter L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 box gutter L1 box gutter L1 L1 L1 P2 L1 box gutter L1 L1 box gutter L1 L1 L1 L1 2 L1 L1 BOX GUTTER L1 RB2 box gutter CANTILEVER 1 R1 (CANOPY) TRUSS ROOF BY OTHERS. ASSUME TRUSS ROOF SPANNING NORTH-SOUTH. ROOF FRAMING PLAN SCALE = 1:100 TRUSS ROOF BY OTHERS R1 TIMBER STUD WALL TRUSS ROOF BY OTHERS TECO BRACKET (TYP.) TECO TRIP-L-GRIP RB 3 RB 3 W P1 W P1 M12-900 'CHEMSET' ANCHORS. 150 EMBEDMENT AFS WALL. REFER ELEVATION FOR DETAILS TECO BRACKET (TYP.) SECTION 1-1 SECTION 12-2 SCALE = 1:10 SCALE = 1:10 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING ROOF FRAMING PLANS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT - Scale @ A1 SIZE SHEET 1:100 U.N.O Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S5 Rev. -- 3 2 4 3 150 AFS/40MPa N12-300 E.W 4 150 AFS/40MPa N12-300 E.W 3 3 4 150 AFS/40MPa N12-300 E.W 4 3 150 AFS/40MPa N12-300 E.W 4 H 3 2 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W G 3 3 2 I 4 1 3 2 4 4 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W K A B C D E F G H I J K 150 AFS/40MPa N12-300 E.W L 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W M A B C D E F G H I J K L 6 4 5 3 3 2 2 1 1 GROUND FLOOR - KEY PLAN A B C D E F G H I J K 3 K 3 2 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W M SCALE 1:200 2 150 AFS/40MPa N12-300 E.W L 6 4 5 3 3 2 2 1 1 LEVEL 1 - KEY PLAN SCALE 1:200 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING WALL ELEVATIONS - SHEET 1 Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT - Scale @ A1 SIZE SHEET 1:100 (U.N.O) Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S7 Rev. -- I H G 2 F F 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W B D G H I 150 AFS/40MPa N12-300 E.W C B 2 150 AFS/40MPa N12-300 E.W A A 2 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W 150 AFS/40MPa N12-300 E.W M A B C D E F G H I J K L 6 4 5 3 3 2 2 1 1 GROUND FLOOR - KEY PLAN M SCALE 1:200 A B C D E F G H I J K L 6 4 5 3 3 2 2 1 1 LEVEL 1 - KEY PLAN SCALE 1:200 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING WALL ELEVATIONS - SHEET 2 Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT - Scale @ A1 SIZE SHEET 1:100 (U.N.O) Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S8 Rev. -- H F I REFER DRG. S12 FOR WALL TO SLAB CONNECTION DETAILS (TYP.) HIGHER GROUND SLAB RAMP (VARIES) N12-300 "Z" BARS N12-250 SIDE REINFORCEMENT CONTINUOUS THROUGHOUT STEP (600 LAP) LOST FORMWORK 400 PF3 BEYOND N12-300 "Z" BARS 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). PF3 BEYOND 450 450 450 450 SECTION F.2 S2 F.1 S3 2 G H REFER PLAN FOR REINFORCMENT. AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) REFER DRG. S12 FOR WALL TO SLAB CONNECTION DETAILS (TYP.) 1 1 AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) REFER DRG. S12 FOR WALL BASE CONNECTION DETAILS (TYP.) REFER PLAN FOR REINFORCEMENT LOST FORMWORK AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) HIGHER GROUND SLAB REFER SECTION F.1 FOR REINFORCEMENT DETAILS RAMP (VARIES) BOUNDARY LINE S2 LOWER GROUND SLAB S3 REFER PLAN FOR REINFORCMENT. LOST FORMWORK PROVIDE POLYSTERENE SEPARATION TO ADJACENT STRUCTURE. LOWER GROUND SLAB REFER PLAN FOR REINFORCEMENT SF 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). REFER PLAN FOR REINFORCMENT. PF 2 1 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). LOWER GROUND SLAB REFER PLAN FOR REINFORCMENT. ADJACENT BRICK GARAGE. 50 mm BLINDING CONCRETE, f'c=15 MPa. 1 SF SF 1 REFER PLAN FOR REINFORCMENT. EB SECTION HIGHER GROUND SLAB 25 REBATE 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). LOWER GROUND SLAB REFER PLAN FOR REINFORCEMENT N12-200 x 1200 LONG STARTER BARS SCABBLE SURFACE (TYP.) LOWER GROUND SLAB REFER PLAN FOR REINFORCEMENT REFER DRG. S12 FOR WALL TO SLAB CONNECTION DETAILS (TYP.) REFER PLAN FOR REINFORCEMENT N12-200 x 1200 LONG STARTER BARS PROVIDE SL92 T&B TO RAMP SLAB REFER PLAN FOR REINFORCEMENT REFER PLAN FOR REINFORCEMENT N12-250 SIDE REINFORCEMENT CONTINUOUS THROUGHOUT STEP (600 LAP) I AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) HATCH DENOTES MASS CONCRETE ON TOP OF SLAB. PROVIDE SL82 T. H FOOTING NOT TO UNDERMINE ADJACENT FOOTING. BUILDER TO CONFIRM ON SITE. 50 mm BLINDING CONCRETE, f'c=15 MPa. 50 mm BLINDING CONCRETE, f'c=15 MPa. REFER PLAN FOR REINFORCMENT. SECTION F.3 S2 SECTION S3 SECTION F.4 S2 S3 F.5 S2 S3 1 2 A AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) REFER PLAN FOR REINFORCMENT. REFER PLAN FOR REINFORCMENT. HIGHER GROUND SLAB LOWER GROUND SLAB 140 BLOCKWORK. N12-400 CENTRAL EACH WAY. BOUNDARY LINE REFER DRG. S12 FOR WALL BASE CONNECTION DETAILS (TYP.) REFER DRG. S11 FOR GRATED TRENCH DETAILS. 1500 MAX. AFS WALL. REFER ELEVATION FOR REINFORCEMENT (TYP.) MASS CONCRETE HIGHER GROUND SLAB 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). 50 mm BLINDING CONCRETE, f'c=15 MPa. 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). REFER PLAN FOR REINFORCMENT. REFER PLAN FOR REINFORCMENT. EB REFER PLAN FOR REINFORCMENT. PF 2 0.2mm THICK POLYTHENE MEMBRANE ON 6mm SCREENINGS LAID OVER 20mm SCREENINGS (75mm MIN. DEPTH). SF 1 EB REFER PLAN FOR REINFORCMENT. 50 mm BLINDING CONCRETE, f'c=15 MPa. 50 mm BLINDING CONCRETE, f'c=15 MPa. SECTION SECTION F.6 S2 S3 S2 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By SECTION F.7 S3 F.8 S2 DRAWING CONCRETE DETAILS - SHEET 1 Designed by HT Drawn by HN Checked by BK Date JUNE 2014 S3 CLIENT Scale @ A1 SIZE SHEET 1:20 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S9 Rev. -- MINIMUM THROUGHOUT U.N.O. ON PLAN. SIDE OF POCKET. 450 TYP. 0.30 Ls 1 ANTI-BURST SPIRAL CAGE COVER 0.20 Ls 1 0.20 Ls SEE NOTE 8. SEE NOTE 8. 0.30 Ls DISTRIBUTION BARS REFER NOTE 3. 0.20 Ls A T 600 STANDARD COG U.N.O. BAND BEAM TENDONS 0.30 Ls COLUMN OR WALL. 150 150 SLAB TENDONS A 0.10 Ls1 ALTERNATE BTM. BARS STAGGERED. Ls1 0.10 Ls2 N12-500 LIGS U.N.O. ON PLAN BAND BEAM WIDTH AS SHOWN ON PLAN A ALTERNATE BTM. BARS STAGGERED. Ls2 A TYPICAL SLAB DEAD END ANCHORAGE DETAIL AGAINST WALL TYPICAL SLAB EDGE LIVE END ANCHORAGE DETAIL TYPICAL SECTION THROUGH BAND BEAM TOP SLAB BARS OR FABRIC. ANTI-BURST SPIRAL CAGE 0.30 Ln1 TYPICAL SLAB POCKET LIVE END ANCHORAGE DETAIL STANDARD COG U.N.O. 0.30 Ln1 SLAB TENDONS 500 LAP 0.20 Ln1 COLUMN OR WALL. 0.30 Ln2 0.20 Ln2 500 LAP 0.20 Ln2 SEE NOTE 8. D ADDITIONAL POCKET REINF'T. REFER PLAN ABOVE 600 N12 LACING BARS STRESSING ANCHOR MIN. COVER COLUMN OR WALL. 0.10 Ln1 MAX. SEE NOTE 8. ALTERNATE BTM. BARS STAGGERED. 0.10 Ln1 MAX. 150 MIN. U.N.O. 0.10 Ln2 MAX. 150 MIN. U.N.O. Ln1 NOTES 1. TYPICAL SLAB DEAD END ANCHORAGE DETAIL SECTION A-A (BEAM SUPPORT) 800 MIN. ADDITIONAL POCKET REINF'T. REFER PLAN ABOVE N12 LACING BARS 2. FOR REINFORCEMENT SIZE & NUMBER SEE PLANS. 7. Ls OR Ln IS THE GREATER OF TWO CONSECUTIVE SPANS (EG. Ls1 & Ls2, Ln1 & Ln2) 3. WHEREVER SLAB REINFORCEMENT IS CALLED UP IN ONE DIRECTION, DISTRIBUTION BARS ARE REQUIRED IN THE TRANSVERSE DIRECTION. ALL TOP AND BTM. DISTRIBUTION BARS NOT SHOWN ON PLAN TO BE N12-300 WITH 300 LAPS. NOT REQUIRED WHERE FABRIC IS SPECIFIED. 8. LONG AND SHORT TOP BARS SHALL BE PLACED ALTERNATELY, WITH AT LEAST 50% OF THESE BEING THE LONGER BAR. NOTES: 4. DETAILS ABOVE APPLY UNLESS SHOWN OTHERWISE ON PLANS. 10. REFER PLANS FOR LIGATURE REQUIREMENTS TO BAND BEAM. 1. REINFORCEMENT SHOWN ON THESE DETAILS IS ADDITIONAL TO THAT SHOWN ON PLANS. 2. DETAILS SHOWN HERE ARE ALSO APPLICABLE TO POST-TENSIONED BAND BEAMS. 3. APPROVED ANTI BURST REINFORCEMENT MAY BE USED IN LIEU OF THE "ANTI-BURST SPIRAL CAGE" SHOWN IN THE ABOVE DETAILS. 5. THE ABOVE ARRANGEMENT ONLY APPLIES WHERE THE RATIO OF THE LONGER TO SHORTER OF ANY TWO ADJACENT SPANS DOES NOT EXCEED 1.2. 11. BUILDER IS TO PROVIDE ADEQUATE BAR CHAIRS OR SUPPORT CAGES TO SUPPORT BAND BEAM TOP REINFORCEMENT. (N.T.S) X3 BEAM DEPTH, D X2 DO NOT CUT OFF STRANDS ON COMPLETION OF STRESSING REFER FLOOR PLANS FOR BTM REINFT TOP & BOTTOM BARS: FOR EVERY TWO BARS STOPPED BY HOLE ADD ONE BAR EACH SIDE OF SAME GRADE AND SIZE. FOR POST TENSIONED SLABS OR WHERE NO BARS ARE SHOWN ADD 2N16 TOP & BTM. EACH SIDE OF HOLE. MINIMUM LAP SPLICES FOR BARS MORE THAN 300mm CONCRETE BELOW BAR SIZE CONCRETE GRADE CONCRETE GRADE 25 MPa > 32 MPa 25 MPa > 32 MPa N12 300 300 400 400 N16 450 450 550 550 N20 600 550 750 700 N24 850 750 1050 950 N28 1050 900 1300 1150 N32 1250 1150 1600 1400 N36 1550 1400 1950 1750 NOTES: 1. THESE SPLICE LENGTHS APPLY FOR ALL BEAMS, SLABS AND WALLS U.N.O. 2. THESE SPLICE LENGTHS ARE BASED ON THE FOLLOWING MINIMUM COVER TO THE BAR: SLABS, WALLS - GREATER OF 25mm OR BAR DIA. BEAMS - 40mm No. Date Revision 2. CO-ORDINATION REQUIRED BY THE POST-TENSIONING AND HYDRAULICS CONTRACTOR ON SITE. 2. CO-ORDINATION REQUIRED BY THE POST-TENSIONING AND HYDRAULICS CONTRACTOR ON SITE. 3. TOTAL ALLOWABLE SLEEVE PENETRATION AT A CROSS-SECTION X1 + X2 + X3 < 0.2W. 3. MAXIMUM SLEEVE DIAMETER X1 < 0.25D. 6N16 x 1000 LONG ADDITIONAL UNDER AND OVER PIPE. VO ID IN SL AB 100 MIN. CLEARANCE. PENETRATIONS PREFERABLY WITHIN MIDDLE THIRD OF BEAM SPAN AND AS CLOSE AS POSSIBLE TO UNDERSIDE OF SLAB. BEAM WIDTH, W TYPICAL PENETRATION IN FLOOR SLAB DETAIL NOTE: CASE 2. - HORIZONTAL SERVICE PIPE PENETRATION NOTES:1. ALL PIPES SHALL BE SLEEVED (NOT CORED). 1. FOR HOLES LESS THAN 300 x 300mm, BARS TO BE RE-ARRANGED AROUND HOLE. 2. CO-ORDINATION REQUIRED BY THE POST-TENSIONING AND HYDRAULICS CONTRACTOR ON SITE. 2. FOR HOLES GREATER THAN 300 x 300mm, BUT LESS THAN 1000 x 1000mm USE ABOVE DETAIL. 3. MAXIMUM SLEEVE DIAMETER X1 < 0.25D. 3. FOR HOLES GREATER THAN 1000 x 1000mm REFER TO ENGINEERS PLANS. This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. By PENETRATIONS PREFERABLY WITHIN MIDDLE THIRD OF BEAM SPAN AND AS CLOSE AS POSSIBLE TO UNDERSIDE OF SLAB. CASE 3. - SIDE ENTRY SERVICE PIPE PENETRATIONS NOTES:1. ALL PIPES SHALL BE SLEEVED (NOT CORED). X1 LESS THAN 300mm CONCRETE BELOW BAR OR VERTICAL BAR CASE 1. - VERTICAL SERVICE PIPE PENETRATION NOTES: 1. ALL PIPES SHALL BE SLEEVED (NOT CORED). 600 BAR BEAM WIDTH, W BEAM WIDTH, W 600 SPLICE(mm) Revision 80 MIN. CLEARANCE. PIPES THROUGH BAND BEAM. SECTION A-A (WALL SUPPORT) Date 9. BARS MAY BE ADJUSTED SIDEWAYS TO AVOID COLUMN BARS. TYPICAL POST-TENSIONED BAND BEAM & SLAB DETAILS X1 No. 6. FOR PRIMARY AND SECONDARY DIRECTIONS OF REINFORCEMENT SEE PLANS. X1 STRESSING ANCHOR TENDON OFFSETS TAKE PRECEDENCE OVER REINFORCEMENT. By BEAM DEPTH, D 12 BAR Ø Ln 2 SECTION A-A ALONG BAND BEAM DO NOT CUT OFF STRANDS ON COMPLETION OF STRESSING REFER FLOOR PLANS FOR BTM REINFT BAND BEAM TENDONS BEAM DEPTH, D N12 x 1500 LONG TOP LACING BARS 0.10 Ls1 BAND BEAM DEPTH 450 TYP. ENSURE DEAD END NO MORE THAN COVER DISTANCE FROM EDGE OF WALL SLAB THICKNESS 800 MIN. TYPICAL SERVICE PIPE PENETRATIONS THROUGH BAND BEAMS DRAWING CONCRETE DETAILS - SHEET 1 Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET 1:20 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S10 Rev. -- N16-200 'Z' BARS P.T CABLE. P.T CABLE. P.T CABLE. LEVEL 1 SLAB LEVEL 1 SLAB LEVEL 1 SLAB 300 P.T CABLE. N12-300 SIDE REINFORCEMENT. 450 (TYP.) AFS WALLL. REFER ELEVATION FOR REINFORCEMENT. 2N16 T&B CONTINUOUS THROUGH DOWN TURN. 600 LAP. SECTION CLEAN SCABBLE SURFACE. SECTION COLUMN. REFER DRG. S8 FOR REINFORCEMENT. SECTION L1.2 S4 L1.3 S4 L1.1 S4 REFER PLAN FOR REINFORCEMENT. WALL BEYOND. REFER PLAN FOR REINFORCEMENT. LEVEL 1 SLAB LEVEL 1 SLAB P.T CABLE AFS WALLL. REFER ELEVATION FOR REINFORCEMENT. P.T CABLE REFER TYPICAL STAIR DETAILS FOR REINFORCEMENT. SECTION SECTION L1.5 S4 L1.4 S4 CL COLUMN AND PAD FOOTING U.N.O. STARTER BARS SAME NUMBER, TYPE, SIZE AND ARRANGEMENT AS FOR COLUMN BARS UNLESS NOTED OTHERWISE IN COLUMN SCHEDULE. 40 BAR DIA. C.J. CLEAN, ROUGHENED SURFACE (TYP.) 20 BAR DIA. REFER OTHERS FOR TRENCH DIMENSIONS & GRATING DETAILS. 'L' 700 2 SETS OF R10 TIES FOR SUPPORT OF STARTER BARS. STANDARD COG IF 'L' IS LESS THAN 35 BAR DIA. 50mm BLINDING CONCRETE (GRADE 15MPa). 150 250 APPROVED FOUNDING LEVEL. CONCRETE GRADE F'c = 40 MPa EXTEND AND COG CORNER BARS ONLY. NOTES: N12-200 EACH WAY CENTRAL. 8N16 R10-200 TIES COLUMN C1 1. FOR REINFORCEMENT, DIMENSIONS ETC, REFER COLUMN SCHEDULE AND PAD FOOTING SCHEDULE. 300 300 150 SLAB LEVEL 5mm THICK COMPRESSIBLE SEPARATION STRIP BETWEEN COLUMN AND SLAB ON GROUND (TYPICAL). TYPICAL GRATED TRENCH DETAIL SCALE = N.T.S SCALE = 1:20 2. OVEREXCAVATION BELOW FOOTINGS TO BE FILLED TO UNDERSIDE OF FOOTING WITH GRADE 15 MPa CONCRETE. 3. OVEREXCAVATION AROUND FOOTINGS TO BE FILLED WITH SAME GRADE CONCRETE AS FOOTINGS OR CEMENT STABILIZED SAND. (7% CEMENT BY VOLUME) 4. DETAILS ABOVE APPLY UNLESS SHOWN OTHERWISE ON DRAWINGS. TYPICAL PAD FOOTING-CONCRETE COLUMN DETAIL SCALE = N/A This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING CONCRETE DETAILS - SHEET 2 Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET 1:20 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S11 Rev. -- REFER WALL ELEVATION FOR REINFORCEMENT (TYP.) 600 300 N16-300 STARTER BARS 300 COG MASONRY NAILS AT 600 CTS. 600 CONCRETE COVER 600 This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING TYPICAL AFS WALL CONNECTION DETAILS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET 1:10 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S12 Rev. -- N12-300 T DISTRIBUTION BARS STARTER BARS. REFER TYPICAL SLAB TO WALL CONNECTION DETAILS. N12-300 T 400 FLIGHT BEYOND SIMILAR TOP OF FLIGHT 40 0 AFS STAIR WALLS N12-150 B 40 0 N12-150 B TYPICAL MID-LANDING CROSS SECTION 150 THICK U.N.O. 15 0 TH R OA T N12-300 T DISTRIBUTION BARS TO PROTRUDE 500 INTO ADJACENT FLOOR SLAB (WHERE POSSIBLE) 40 0 150 THICK U.N.O. ON FLOOR PLANS 500 N12-150 B FLIGHT BEYOND SIMILAR 0 N12-300 T BOTTOM OF FLIGHT N12-150 T&B BASE LEVEL 300 MIN. 500 N12-300 DISTRIBUTION BARS 40 40 0 N12-150 B C.J. SCABBLED FULLY SCABBLED C.J. (OPTIONAL) REFER TYPICAL SLAB TO WALL CONNECTION DETAILS FOR REINFORCEMENT (TYP). AFS STAIR WALLS TYPICAL STAIR WITH MID-LANDING DETAIL TYPICAL LANDING AT FLOOR LEVEL CROSS SECTION TYPICAL STAIR BASE DETAIL NOTE: 11 No. MAXIMUM RISERS PER FLIGHT This Drawings and the Design shown HEREON is the property of KPA MANAGEMENT & CONSULTING PTY LTD and shall not be copied nor reproduced in part or in whole in any form without the written permission of KPA MANAGEMENT & CONSULTING PTY LTD and shall be used ONLY by the client of KPA MANAGEMENT & CONSULTING PTY LTD for the project for which it was provided. No. Date Revision By No. Date Revision By DRAWING CONCRETE STAIR DETAILS Designed by HT Drawn by HN Checked by BK Date JUNE 2014 CLIENT Scale @ A1 SIZE SHEET 1:20 Job No. XXX PROJECT PROPOSED 11 UNIT DEVELOPMENT AT 27 CHANDLER ROAD , BORONIA Drawing No. S13 Rev. --