Pressure transducer with amp. PA-110

advertisement
COPAL ELECTRONICS
PRESSURE TRANSDUCERS WITH AMP.
PA-110
INTERNAL STRUCTURE
5
1
A Port
2
B Port
3
4
Part name
■FEATURES
1
Sensor chip
● Heavy-duty casing for ourdoor use
● Supply voltage : 5 VDC or 12 VDC
● Built-in temperature compensation
2
Pressure Port
3
Housing
4
“O” ring
5
Resin compound
Material
Silicone
PPS (Polyphenylene sulphide)
Nitrile rubber
Silicone gel
■MODEL NUMBER DESIGNATION
PA-110-102D-012
Supply voltage
Series name
012:12 VDC
005: 5 VDC
Rated pressure range
102: 0 ~ 100 kPa
Pressure refence
D:Differntial
■LIST OF MODEL NUMBERS
Differential
Pressure reference
Rated pressure range
kPa
Supply voltage
VDC
Model number
0 ~ 100
12
5
PA-110-102D-012
PA-110-102D-005
※Verify the above model numbers when placing orders.
■ Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
PA-110
PRESSURE TRANSDUCERS WITH AMP.
■STANDARD SPECIFICATIONS
K Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 5 V DC or 12 VDC.
Item
PA-110
Model number
102D-012
102D-005
General specifications
Pressure reference
Differential
Rated pressure range
kPa
100
Maximum pressure
kPa
200
Break-down pressure
kPa
500
Operating temp. range
°C
− 20 ~ 70
%RH
Operating humidity
°C
Storage temp.
35 ~ 85(No condensation)
− 20 ~ 80(Atmospheric pressure, humidity 65 %RH maximum)
Pressure medium
Non-corrosive gases
g
Power
Net weight
Analog output
Approx. 70
12 ± 0.25 V
5 ± 0.1 V
Supply voltage
V DC
Ripple content
maximum
10 %(P-P)
Consumption current
maximum
10 mA
Output voltage
Zero voltage
※1
Span voltage
※1
Output current
V
0.5 ~ 4.5
V
0.5 ± 0.04
V
4.0 ± 0.04
mA
maximum
0.5(Load resistance 10 kΩ minimum)
Linearity/Hysteresis
%F.S.
± 0.5
Thermal error -20 ~ 70 °C
(Reference temp.: 25 °C)
%F.S.
±3
Response
※1
φ 4.5
mm
Pressure port
ms
2
The zero and span voltages of 5 V vary in proportion to the supply voltage.
■ Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.
COPAL ELECTRONICS
PA-110
PRESSURE TRANSDUCERS WITH AMP.
■ENVIRONMENTAL CHARACTERISTICS
Test item
Test conditions (At 25 ± 5 °C)
Vibration
10 ~ 500 Hz, 1.5 mm maximum/294 m/s ,
3 directions for 2 hours each
Shock
490 m/s2, 3 directions for 3 times each
Pressure cycling
0 ~ Rated pressure, 10 cycles
Moisture resistance
40 °C, 90 ~ 95 %RH, 240 hrs.
Permissible change
2
Zero voltage/Span voltage:
± 1 %F.S. maximum
6
■OUTLINE DIMENSIONS
ᰑ Output
30
φ 4.5
1
°
ᰒ Common
ᰓ Power (+)
φ 5.5 ± 0.1
Unless otherwise specified, tolerance : ± 0.5 (Unit: mm)
A port
4
17
B port
port
[ Pressure
Tolerance : 0.2 (mm) ]
Output connectors
Applied plug
AMP econoseal J series Mark (+)
Made in Tyco Electronics AMP K.K.
Plug Housing
174357-2
Double Lock Plate
174358-1
Contact
Seal Ring
Label 1 (Polyester)
(55)
Laser marking
Part No.
Housing 1 (PPS)
19
37
Pin No.
1
2
3
36
50
Housing 2 (PPS)
8.5
Metal color insert (Brass)
Connection
Output
Common
Power B
13.5
2 – φ 5.5
11.5
16
64
33
■INTERNAL ELECTRICAL SCHEMATICS
– 012 (12 VDC)
– 005 (5 VDC)
PressureA
Power B PressureA
Sensor
PressureB
Main circuit
Common C
Output
PressureB
Power B
Sensor
Main circuit
Common C
Output
■ Specifications are subject to change without notice. Specifications in this catalog are for reference. The formal specification sheets will be submitted upon request.